DISTRIBUTION SYSTEMS - PRIMARY HYDRAULIC POWER SYSTEM Oil Supply 1. 2. 3. 4. 5.
Oil Level Sight Glass Oil Level Sensor Reservoir Tank Outlet Strainer Tank Drain
The hydraulic system is supplied with Hy-Tran Ultra from a central reservoir tank that is mounted behind the PTO gearbox. The tank contains approximately 57L (15 gal) of oil and should be changed out every 1000 hours of operation. A float type gauge that is mounted in the top of the tanks monitors the proper oil level. The float provides an Open/Closed signal to the Universal Display Plus monitor. The switch is N.C. when held in the operating position, open when oil is present. The tank incorporates a discharge port strainer and tank breather. The strainer is rated at 100 micron of protection and supplies the gear pumps.
6
A.10.A / 11