HYDRAULIC / HYDROSTATIC SYSTEM (CONT’D) Removing And Replacing Hydraulic Charge Filter For the correct service interval SCHEDULE on Page 10-70-1.)

(See

WARNING

SERVICE

Hydraulic fluid escaping under pressure can have sufficient force to enter a person’s body by penetrating the skin. This can cause serious injury and possible death if proper medical treatment by a physician familiar with this injury is not received immediately.

Raise the operator cab. (See Raising on Page 10-30-1.) Figure 10-120-7

W-2145-0290

Check the fluid level in the reservoir and add as needed. 1

Breather Cap

2

For the correct service interval SCHEDULE on Page 10-70-1.)

1

(See

SERVICE

Figure 10-120-8 S4254

Remove the hydraulic connections (Item 1) and remove the charge filter (Item 2) [Figure 10-120-7]. Replace the entire filter.

1

WARNING AVOID INJURY OR DEATH Always clean up spilled fuel or oil. Keep heat, flames, sparks or lighted tobacco away from fuel and oil. Failure to use care around combustibles can cause explosion or fire. W-2103-0508

Lower the operator cab. (See Lowering on Page 10-302.)

S4031A

Remove the hydraulic fill / breather cap (Item 1) [Figure 10-120-8] and discard.

Install a new cap.

Start the engine and operate the loader hydraulic controls. Stop the engine and check for leaks.

10-120-5