Caterpillar cat ep12krt pac forklift lift trucks service repair manual sn:etb10a 30001 and up (contr

Page 34

MOTORS

Troubleshooting Low supply voltage

Motor does not start.

Blown fuse Excess load Faulty wire connection Broken wire in control device Broken wire in field coil Broken wire in armature coil

Charge battery and improve power supply condition. Replace. Reduce load. Repair, or re-tighten wire connections. Repair or replace. Repair or replace. Repair or replace.

Motor starts but does not run at rated speed.

Low supply voltage Faulty connection at armature circuit

Charge battery and improve power supply condition. Repair connections.

Motor produces abnormal vibrations and noise.

Defective bearings Loose mounting bolts Contact between armature and field coil

Replace bearings. Retighten bolts and nuts. Repair or replace.

Incorrect installation Severe external vibration

Correct installation condition. Remove the cause of vibration, or take appropriate vibration-insulating measures. Replace. Replace.

Bearing overheats. Defective bearings Oil degradation or shortage in bearings

3-8


Issuu converts static files into: digital portfolios, online yearbooks, online catalogs, digital photo albums and more. Sign up and create your flipbook.