HYDRAULIC, PNEUMATIC, ELECTRICAL, ELECTRONIC SYSTEMS - PRIMARY HYDRAULIC POWER SYSTEM

4.

If the pressure reading is not to the specification, adjust the flow compensating valve (1). If the pressure reading is high, examine the flow compensating valve (1) spool for sticking.

BVE0154B

3

BVE0153A

4

BVE0154A

5

Maximum Pressure 5.

6.

Remove the pressure compensating valve plug and install the 90 ° quick release fitting adaptor 380001146 (1). - Test port thread M8 x 1.0

Attach a 0 - 250 bar (0 - 3625 psi) pressure gauge 380000553, using the quick release coupler 380000543 (1) and the hose 380000545.

MAXXUM-T3-DRAFT 02/11/2011