If Equipped with Auxiliary Hydraulic Mode Switch (Item 5) [Figure 10-190-1]: Do the following procedure with the switch in the “B” position”.

AUXILIARY HYDRAULIC CONTROL SYSTEM Inspecting Deactivation Of The Auxiliary Hydraulic Continuos Flow

1. Stop the engine and engage the Parking Brake (Item 1) [Figure 10-190-1].

Figure 10-190-1 5

2. Make sure the area around the machine is clear of bystanders.

2

3. Set the engine speed to slow (Item 2) [Figure 10-1901].

4 1

4. Turn the key to the ON position but do not start the engine. 5. Move the auxiliary hydraulic control lever (Item 4) [Figure 10-190-1] fully forward into the locked (detent) position.

3 P-81916A

1. Stop the engine and engage the Parking Brake (Item 1) [Figure 10-190-1]. 2. Make sure the area around the machine is clear of bystanders.

6. Depress the Continuous Flow Shutoff Lever (Item 3) [Figure 10-190-1] so the lever is in the DOWN position. 7. The auxiliary hydraulic control lever must return to the NEUTRAL position

3. Set the engine speed to slow (Item 2) [Figure 10-1901].

8. Repeat the procedure with the auxiliary hydraulic control lever (Item 4) [Figure 10-190-1] fully backward into the locked (detent) position.

4. Turn the key to the ON position but do not start the engine.

9. Move the Auxiliary Hydraulic Mode Switch (Item 5) [Figure 10-190-1] back to the "A" position.

5. Depress the Continuous Flow Shutoff Lever (Item 3) [Figure 10-190-1] so the lever is in the DOWN position.

NOTE: If any of the controls in these previous inspection procedures do not function properly, contact your dealer for service. DO NOT modify the system.

6. Move the auxiliary hydraulic control lever (Item 4) [Figure 10-190-1] fully forward into the locked (detent) position. 7. Release the Continuous Flow Shutoff Lever (Item 3) [Figure 10-190-1]. The lever must return to the UP position. 8. The auxiliary hydraulic control lever (Item 4) [Figure 10-190-1] must move to neutral in approximately one to three second. 9. Repeat the procedure with the auxiliary hydraulic control lever (Item 4) [Figure 10-190-1] fully backward into the locked (detent) position.

WARNING The Reverse Stop Panel, Neutral Start Interlocks, and Lift/Tilt Lockouts must function properly. •

The Reverse Stop Panel must stop mini loader from moving backward when panel is pushed forward. • The Lift/Tilt Lockouts must deactivate the lift and tilt functions when engine is off. If any of these do not function properly, contact your dealer for service. DO NOT modify system.

If Equipped with With Auxiliary Hydraulic Mode Switch (Item 5) [Figure 10-190-1]: Do the Above procedure with the switch in the “A” position.