Skip to main content

Construction Documents

Page 1

GENERAL NOTE

Project Consultant Nadim Itani E-Mail: nritani@cpp.edu Structural Engineer Gary L. McGavin E-Mail: gmcgavin@cpp.edu Construction Manager Micheal Fox E-Mail: mfox@cpp.edu MEP Engineer Hofu Wu E-Mail: hwu@cpp.edu Codes Consultant Andrew Thul E-Mail: athul@cpp.edu

WESLEY MASON

wwmason@cpp.edu

Instructor:

NADIM ITANI

WEST HOLLYWOOD MULTI-FAMILY HOUSING 1047 N Spaulding Ave West Hollywood, CA 90046 CITY OF WEST HOLLYWOOD

TITLE

Description

Date

COVER SHEET

Job # Date

01 9 May, 2018 24 x 36

Size Drawn by

WESLEY MASON 00

Revision #

G 0.0 Scale

6/26/2018 6:30 PM

No.


GENERAL NOTE

SYMBOLS LEGEND

PROJECT CONSULTANTS

1 A 5.1

BUILDING SECTION

DETAIL REFERENCE

1 A D B C

A A STRUCTURAL GRID

WESLEY MASON 3801 W. TEMPLE AVE. POMONA, CA 91786

NADIM ITANI 3801 W. TEMPLE AVE. POMONA, CA 91786

wwmason@cpp.edu

nritani@cpp.edu

STRUCTURAL ENGINEER

CONSTRUCTION MANAGER:

GARY L. MCGAVIN 3801 W. TEMPLE AVE. POMONA, CA 91786

MICHAEL FOX 3801 W. TEMPLE AVE. POMONA, CA 91786

gmcgavin@cpp.edu

michaelfox@cpp.edu

DOOR AND WINDOW REFERENCE TAG

1 A 5.1 SETBACKS

PROJECT CONSULTANT:

NORTH ARROW

D5

INTERIOR ELEVATION

OWNER:

BREAK LINE

Project Consultant Nadim Itani E-Mail: nritani@cpp.edu Structural Engineer Gary L. McGavin E-Mail: gmcgavin@cpp.edu Construction Manager Micheal Fox E-Mail: mfox@cpp.edu MEP Engineer Hofu Wu E-Mail: hwu@cpp.edu

MEP ENGINEER

CODE CONSULTANT:

HOFU WU 3801 W. TEMPLE AVE. POMONA, CA 91786

ANDREW THUL 3801 W. TEMPLE AVE. POMONA, CA 91786

hwu@cpp.edu

athul@cpp.edu

Codes Consultant Andrew Thul E-Mail: athul@cpp.edu

1"

DETAIL CALLOUT

SETBACKS

DIMENSION LINE

wwmason@cpp.edu

WESLEY MASON Instructor:

NADIM ITANI

WEST HOLLYWOOD MULTI-FAMILY HOUSING 1047 N Spaulding Ave West Hollywood, CA 90046

PROJECT INFORMATION

CITY OF WEST HOLLYWOOD

USE: MULTI-FAMILY HOUSING TOP BUILDING HEIGHT: 32' LEGAL DESCRIPTION: APP: 5530015029 OCCUPANCY GROUP: R-2 / S-1 TYPE OF CONSTRUCTION : TYPE V-A ZONING: R-3B SITE DATA:

No.

Description

Date

LOT SIZE: 0.3 ACRES SITE AREA: 13,000 SF FOOTAGE DATA: PROJECT DENSITY: 10 UNITS - 6 ONE BEDROOM FLATS (600 - 675 SF) - 2 TWO BEDROOM FLATS (1008 SF) - 2 TOWN HOME UNITS (1417 SF) PROPOSED LOT COVERAGE: 36% STORIES: 2 PARKING: - REQUIRED: 18 SPACES - PROVIDED: 18 SPACES SETBACKS: - 20 FEET FROM FRONT - 15 FEET FROM REAR - 6 FEET FROM SIDE

TITLE

LOT INFORMATION 1047 N SPALDING AVE W HOLLYWOOD, CA 91106 ASSESSOR ID NO. 5530-015-030

TITLE SHEET

Job # Date

01 9 May, 2018 24 x 36

Size Drawn by

WESLEY MASON 00

Revision #

G 0.1 Scale

6/26/2018 6:30 PM

VICINITY MAP


GENERAL NOTE

Project Consultant Nadim Itani E-Mail: nritani@cpp.edu Structural Engineer Gary L. McGavin E-Mail: gmcgavin@cpp.edu Construction Manager Micheal Fox E-Mail: mfox@cpp.edu MEP Engineer Hofu Wu E-Mail: hwu@cpp.edu Codes Consultant Andrew Thul E-Mail: athul@cpp.edu

WESLEY MASON

wwmason@cpp.edu

Instructor:

NADIM ITANI

WEST HOLLYWOOD MULTI-FAMILY HOUSING 1047 N Spaulding Ave West Hollywood, CA 90046 CITY OF WEST HOLLYWOOD

No.

Description

Date

TITLE

GENERAL NOTES Job #

01 9 May, 2018

Size Drawn by

24 x 36 WESLEY MASON

Revision #

00

G 0.2 Scale

6/26/2018 6:30 PM

Date


GENERAL NOTE

Project Consultant Nadim Itani E-Mail: nritani@cpp.edu Structural Engineer Gary L. McGavin E-Mail: gmcgavin@cpp.edu Construction Manager Micheal Fox E-Mail: mfox@cpp.edu MEP Engineer Hofu Wu E-Mail: hwu@cpp.edu Codes Consultant Andrew Thul E-Mail: athul@cpp.edu

WESLEY MASON

wwmason@cpp.edu

Instructor:

NADIM ITANI

WEST HOLLYWOOD MULTI-FAMILY HOUSING 1047 N Spaulding Ave West Hollywood, CA 90046 CITY OF WEST HOLLYWOOD

No.

Description

Date

TITLE

GENERAL NOTES Job #

01 9 May, 2018

Size Drawn by

24 x 36 WESLEY MASON

Revision #

00

G 0.3 Scale

6/26/2018 6:30 PM

Date


GENERAL NOTE

Project Consultant Nadim Itani E-Mail: nritani@cpp.edu Structural Engineer Gary L. McGavin E-Mail: gmcgavin@cpp.edu Construction Manager Micheal Fox E-Mail: mfox@cpp.edu MEP Engineer Hofu Wu E-Mail: hwu@cpp.edu Codes Consultant Andrew Thul E-Mail: athul@cpp.edu

WESLEY MASON

wwmason@cpp.edu

Instructor:

NADIM ITANI

WEST HOLLYWOOD MULTI-FAMILY HOUSING 1047 N Spaulding Ave West Hollywood, CA 90046 CITY OF WEST HOLLYWOOD

No.

Description

Date

TITLE

TOPOGRAPHIC SURVEY Job #

01 9 May, 2018

Size Drawn by

24 x 36 WESLEY MASON

Revision #

00

G 0.4 Scale

6/26/2018 6:30 PM

Date


GENERAL NOTE

SPECIAL CONSTRUCTION REQUIREMENTS

MAXIMUM AREA OF EXTERIOR WALL OPENING

SEPERATION BETWEEN RESIDENTIAL UNITS = 1 HR. (TABLE 420.2/709.3) EGRESS ENCLOSE FROM RESIDENTIAL = 2 HR. (TABLE 102.1)

FIRE SEPERATION DISTANCE 3’ TO 5’ UNPROTECTED, SPRINKLERED = 15% FIRE SEPERATION DISTANCE 5’ TO 10’ TYPES OF CONSTRUCTION: (TABLE 601) TYPE I-A: S-2 PARKING GARAGE UNPROTECTED, SPRINKLERED = 25% FIRE SEPERATION DISTANCE 10’ TO 15’ TYPE V-A: R-2 RESIDENTIAL UNPROTECTED, SPRINKLERED = 45% ALLOWABLE HEIGHTS: (TABLE 503) FIRE SEPERATION DISTANCE 15’ TO 20’ R-2, SM 60 FT UNPROTECTED, SPRINKLERED = 75% PROPOSED HEIGHT 32’ FIRE SEPERATION DISTANCE 20’ TO 25’ UNPROTECTED, SPRINKLERED = NO LIMIT

BEARING WALLEXTERIOR = 2 HOUR FIRE BARRIER SEPERATION BETWEEN UNITS = 1 HOUR FIRE BARRIER WALL = 0 HOUR EXIT STAIRS

Structural Engineer Gary L. McGavin E-Mail: gmcgavin@cpp.edu Construction Manager Micheal Fox E-Mail: mfox@cpp.edu MEP Engineer Hofu Wu E-Mail: hwu@cpp.edu Codes Consultant Andrew Thul E-Mail: athul@cpp.edu

AREA OF FOCUS

11' 4"

P.L.

6'-3"

6'

10% SLOPE RUN=10'

20% SLOPE RUN=62' 7"

10% SLOPE RUN=10'

WESLEY MASON

2

24'

3

ELEV. MECH. ROOM

M.E.P. ROOM

VAN ACCESSIBLE ADA SPACE 11'

30' 7" FROM PROPERTY LINE TO CENTER LINE STREET

4

C.L. COL.

NADIM ITANI

WEST HOLLYWOOD MULTI-FAMILY HOUSING 1047 N Spaulding Ave West Hollywood, CA 90046

7'

50' 7"

P2

wwmason@cpp.edu

Instructor:

F.D.C

15'

Aa = [At + (At x It) + (At x Is)] = [ 12,000 SF + (12,000 SF x = ALLOWABLE BUILDING PER STORY = PROPOSED AREA: FIRST STORY: 4740 SF SECOND STORY: 6062 SF

C.L. COL.

13'-6"

1

P1

28'-6"

CITY OF WEST HOLLYWOOD 16

17

18

18'

5

20'

UP 34'

24'

ALLOWABLE AREA FORMULA Aa = [At + (At x It) + (At x Is)] Aa = ALLOWABLE BUILDING AREA PER STORY At = TABULAR BUILDING AREA PER STORY (TABLE 503) It = AREA INCREASE FACTOR DUE TO FRONTAGE (SEC 506.2) Is = AREA INCREASE FACTOR DUE TO SPRINKLER PROTECTION (SEC 506.3)

Project Consultant Nadim Itani E-Mail: nritani@cpp.edu

PRIMARY STRUCTUAL FRAME = 1 HR. (TABLE 601) BEARING WALL EXTERIOR = 2 HR. (TABLE 601) BEARING WALL INTERIOR = 1 HR. (TABLE 601) NON-BEARING WALL INTERIOR AND EXTERIOR PARTITION = 0 HR. (TABLE 601) FLOOR CONSTRUCTION AND SECONDARY MEMBERS =1 HR. (TABLE 601) ROOF CONSTRUCTION AND SECONDARY MEMBERS = 1 HR. (TABLE 601)

28'-6"

OCCUPANCY CLASSIFICATIONS: PARKING GARAGE: S-2 1 LEVEL RESIDENTIAL: R-2 2 LEVELS

6 20'-9"

DN N DN

C.L. COL.

P3

7

8

9

10

12

11

13

14

15

16' 3"

No. 29'-9"

14'

PA

PF

AREA OF FOCUS

19'-6"

PB

13'-8"

28'-6"

PD

PC

47' 8"

PE

PF

PG

47' 8"

7'

18'-10"

7' 10"

5'

7'

9' 11"

32' 9"

B-B A 3.2

11'-2"

11

17' 7"

5'

13'-6"

14'-6"

8'-10"

11

10 10' 6"

5'-8"

10

7' 6"

8 10'-2"

15' 7' 6"

15'

8

22' 5"

9

9

7 8'-8"

7

6 25' 7"

8'-10" 14'-6"

TITLE

24'-4"

5'

FIRE LIFE SAFETY

5

5'-8"

5 4

8' 3"

4

4'

2

7' 6"

A-A A 3.1

A-A A 3.1 10'-2"

A-A A 3.1

7' 6"

A-A A 3.1

15'

19'-10"

Drawn by

9' 8"

8' 4"

10' 4"

21'-10"

20' FRONT SETBACK F.O.F.

11'

8'-2"

8' 7"

B-B A 3.2

B-B A 3.2

16' 11"

17'

4'-11"

15' REAR SETBACK F.O.F.

15' REAR SETBACK F.O.F.

01 9 May, 2018

Size

1

1

Job # Date

24 x 36 WESLEY MASON

Revision # 62' 4"

00

11' 20' FRONT SETBACK F.O.F.

95'

95'

A

B

C

D

E

F G

H

I

A

B

C

D

E

F G

H

G 1.1

I

Scale

6/26/2018 6:30 PM

15'

2

22' 5"

3

3

6' SIDE SETBACK F.O.F.

PRIVATE OPEN SPACE: REQUIRED: 120 SF PER UNIT PROVIDED: 120 - 150 SF

Date

B-B A 3.2

9'-10"

6' SIDE SETBACK F.O.F.

6

COMMON OPEN SPACE: REQUIRED: 500 SF PROVIDED: 679 SF

Description

19'-3"

AREA OF FOCUS

8'

SETBACKS: FRONT: AVERAGE OF TWO ADJACENT BUILDINGS = 30 FEET ACTUAL NEEDED = 15 FEET 20 FEET PROVIDED WITH INCENTIVES SIDE: 5 FEET FOR TWO STORIES 5 FEET ALLOWED 6 FEET PROVIDED REAR: 15 FEET ALLOWED 15 FEET PROVIDED

6'

14'

P3


GENERAL NOTE

ALLOWABLE OPENING = 25%

ALLOWABLE OPENING = 25%

AREA OF FOCUS

AREA OF FOCUS

47' 8"

47' 8"

7'

18'-10"

11' 4" TO ADJACENT BUILDING

6' SIDE SETBACK F.O.F.

11

5'

10' 6"

5'-8"

ALLOWABLE OPENING = 15%

7' 6"

8 10'-2"

15'

15'

8

22' 5"

9

9

5

33'

5 5'-8"

4

4

25' 7"

ALLOWABLE OPENING =UNLIMITED

8'

6

ALLOWABLE OPENING = 15%

5'-8"

ALLOWABLE OPENING = 25% ACTUAL OPENING = 25%

ALLOWABLE OPENING =45%

5'

FIRE SEPERATION DISTANCE 20’ TO 25’ UNPROTECTED, SPRINKLERED = NO LIMIT

33'

ALLOWABLE OPENING =45%

6

ALLOWABLE OPENING =UNLIMITED

8'

ALLOWABLE OPENING = 25% ACTUAL OPENING = 25%

ALLOWABLE OPENING = 25%

4' A-A A 3.1

A-A A 3.1

A-A A 3.1

22' 5"

2

7' 6" 15'

2

MEP Engineer Hofu Wu E-Mail: hwu@cpp.edu Codes Consultant Andrew Thul E-Mail: athul@cpp.edu

3

3

Structural Engineer Gary L. McGavin E-Mail: gmcgavin@cpp.edu Construction Manager Micheal Fox E-Mail: mfox@cpp.edu

7

7

14'-6"

A-A A 3.1

1

9' 8"

17'

10' 4"

8' 7"

4'-11"

15' REAR SETBACK F.O.F.

15' REAR SETBACK F.O.F.

16' 3" TO ADJACENT BUILDING

20' FRONT SETBACK F.O.F.

11'

B-B A 3.2

16' 3" TO ADJACENT BUILDING

6' SIDE SETBACK F.O.F.

1

B-B A 3.2

11' 20' FRONT SETBACK F.O.F.

95'

95'

ALLOWABLE

ALLOWABLE

OPENING = 75%

OPENING = 75%

A

B

D

C

E

F G

H

A

I

B

C

D

E

F G

H

I

WESLEY MASON

wwmason@cpp.edu

Instructor:

NADIM ITANI

WEST HOLLYWOOD MULTI-FAMILY HOUSING 1047 N Spaulding Ave West Hollywood, CA 90046 CITY OF WEST HOLLYWOOD

I

P.L.

H

F

G

E

D C

B

A

P.L.

P.L.

11

10

9

8

7

6

5

4

3

2

1

P.L.

No.

NORTH ELEVATION

A

B

Date

WEST ELEVATION

ALLOWABLE OPENING = 25% ACTUAL OPENING = 25% P.L.

Description

C

D

E

F G

ALLOWABLE OPENING = 45% ACTUAL OPENING = 42% H

I

P.L.

P.L.

1

2

3

4

5

6

7

8

9

10

11

P.L.

TITLE

WALL TO WINDOW RATIOS Job # SOUTH ELEVATION

EAST ELEVATION

Date

01 9 May, 2018 24 x 36

Size

ALLOWABLE OPENING = 75% ACTUAL OPENING = 31%

ALLOWABLE OPENING = UNLIMITED ACTUAL OPENING = 12%

Drawn by

WESLEY MASON 00

Revision #

G 1.2 Scale

1/8" = 1-0"

6/26/2018 6:30 PM

FIRE SEPERATION DISTANCE 15’ TO 20’ UNPROTECTED, SPRINKLERED = 75%

Project Consultant Nadim Itani E-Mail: nritani@cpp.edu

10

10

8'-10"

FIRE SEPERATION DISTANCE 10’ TO 15’ UNPROTECTED, SPRINKLERED = 45%

17' 7"

13'-6"

14'-6"

8'-10"

11

FIRE SEPERATION DISTANCE 5’ TO 10’ UNPROTECTED, SPRINKLERED = 25%

7'

9' 11"

B-B A 3.2

9'-10"

B-B A 3.2

FIRE SEPERATION DISTANCE 3’ TO 5’ UNPROTECTED, SPRINKLERED = 15%

11' 4" TO ADJACENT BUILDING

MAXIMUM AREA OF EXTERIOR WALL OPENING


GENERAL NOTE

MEANS OF EGRESS

OCCUPANCY LOAD (TABLE 1001.1.1)

1003.2 CEILING HEIGHT: MINIMUM SHALL NOT BE LESS THATN 7’ 6”

FUNCTION OF SPACE PARKING RESIDENTIAL

TABLE 1004.1.2: MAX FLOOR AREA ALLOWANCES PER OCCUPANT IN RESIDENTIAL HAS OCCUPANT LOAD FACTOR OF 200 GROSS

OCCUPANT LOAD FACTOR 200 GROSS 200 GROSS

TOTAL PARKING GROSS SQUARE FOOTAGE:

1005.3.1: STAIRWAYS SIZING: FOR OTHER THAN GROUP H AND I-2 OCCUPANCIES, THE CAPACITY IN INCHES OF MEANS OF EGRESS STAIRWAY SHALL BE CALCULATED BY MULTIPLYING THE OCCUPANT LOAD SERVED BY SUCH STAIRWAY BY A MEANS OF EGRESS FACTOR OF 0.2 PER OCCUPANT IN A BUILDING EQUIPPED THROUGHOUT WITH AN AUTOMATIC SPRINKLER INSTALLED WITH ACCORDANCE OF SECTION 903.3.1 SECOND STAIR:

Project Consultant Nadim Itani E-Mail: nritani@cpp.edu

10,372 SF / 200 GROSS = 51.86 = 52 PEOPLE

Structural Engineer Gary L. McGavin E-Mail: gmcgavin@cpp.edu

TOTAL RESIDENTIAL GROSS SQUARE FOOTAGE:

Construction Manager Micheal Fox E-Mail: mfox@cpp.edu

10,802 SF / 200 GROSS / 10 UNITS = 5.4 = 6 PEOPLE/ FLOOR FIRST LEVEL = 4740 SF / 200 GROSS / 10 UNITS = 2.4 = 3 PEOPLE PER UNITS PER FLOOR SECOND LEVEL = 6062 SF / 200 GROSS / 10 UNITS = 3.03 = 4 PEOPLE PER UNIT PER FLOOR

1005.4: CONTINUITY: THE MINIMUM WIDTH OR REQUIRED CAPACITY OF THE MEANS OF EGRESS REQUIRED FROM ANY STORY OF A BUILDING SHALL NOT BE REDUCED ALONG THE PATH OF EGRESS TRAVEL UNTILL ARRIVAL AT PUBLIC WAY

MEP Engineer Hofu Wu E-Mail: hwu@cpp.edu Codes Consultant Andrew Thul E-Mail: athul@cpp.edu

AREA OF FOCUS

WESLEY MASON

P1

C.L. COL.

24'

ELEV. MECH. ROOM

NADIM ITANI

WEST HOLLYWOOD MULTI-FAMILY HOUSING 1047 N Spaulding Ave West Hollywood, CA 90046

2

3

wwmason@cpp.edu

Instructor:

10% SLOPE RUN=10'

20% SLOPE RUN=62' 7"

10% SLOPE RUN=10'

13'-6"

1

28'-6"

1006.2.1: EGRESS BASED ON OCCUPANT LOAD PLUS COMMON PATH OF TRAVEL WITH EXCEPTION: IN GROUP R-2 AND R-3 OCCUPANCIES, 1 MEANS OF EGRESS IS PERMITTED WITH IN AND FROM INDIVIDUAL DWELLING UNITS. 2 EXITS OR EXIT ACCESS DOORWAY ARE REQUIRED

6'-3"

COMMON PATH OF TRAVEL MAIN EXIT PATH EXIT STAIRS

M.E.P. ROOM

VAN N ACCESSIBLE ADA D SPACE 11'

P2

28'-6"

7 7'

CITY OF WEST HOLLYWOOD

4

C.L. COL.

16

17

18

18'

34'

TABLE 1006.3.2: OCCUPANT LOAD PER STORY: 1-500 MIN. NUMBER OF EXIT: 2

24'

5

20'-9"

6

C.L. COL.

P3

9

10

12

11

13

14

15

No.

29'-9"

14'

PA

1010.1.2.1: DIRECTION OF DOOR SWING: SWING IN DIRECTION OF TRAVEL IF SPACE HAS OCCUPANT LOAD OF MORE THAN 50

8

14'

1010.1.1: SIZE OF DOOR: SHALL NOT BE LESS THAN 32” WITHIN UNITS AND SHALL NOT BE MORE THAN 78” HEIGHT

7

AREA OF FOCUS

19'-6"

PB

13'-8"

28'-6"

PD

PC

Description

Date

19'-3"

PE

PF

PG

AREA OF FOCUS 47' 8"

47' 8"

7'

18'-10"

7' 10"

5'

7'

9' 11"

32' 9"

B-B A 3.2

11'-2"

B-B A 3.2

9'-10"

6' SIDE SETBACK F.O.F.

11

17' 7"

13'-6" 5'

10 10' 6"

5'-8"

10

7' 6"

8

7' 6"

10'-2"

15'

8

22' 5"

9

9

15'

101.10.1.8: DOOR ARRANGEMENT: SPACE BETWEEN 2 DOORS IN A SERIES SHALL BE 48” MIN. PLUS WIDTH OF DOOR SWING INTO A SPACE

14'-6"

8'-10"

11

7

7 8'

8'-8"

TITLE

MEANS OF EGRESS

6

14'-6"

8'-10"

25' 7"

6

24'-4"

5'

1011.3: STAIR HEAD ROOM: CLEARANCE NOT LESS THAN 80” MEASURED FROM STAIR NOSING

5

Job #

5'-8"

5

8' 3"

Date

4' A-A A 3.1

A-A A 3.1 10'-2"

01 9 May, 2018

Size Drawn by

24 x 36 WESLEY MASON

Revision #

1

1

22' 5"

2

7' 6" A-A A 3.1

7' 6"

A-A A 3.1

15'

19'-10"

15'

00

16' 11"

17'

9' 8"

8' 4"

10' 4"

21'-10"

8'-2"

8' 7"

B-B A 3.2

20' FRONT SETBACK F.O.F.

11'

4'-11"

15' REAR SETBACK F.O.F.

15' REAR SETBACK F.O.F.

62' 4"

G 1.3

11' 20' FRONT SETBACK F.O.F.

95'

95'

A

B

C

D

E

F G

H

I

A

B

C

D

E

F G

H

I

Scale

6/26/2018 6:30 PM

2

B-B A 3.2

1014.2: HEIGHT OF HANDRAIL: NOT LESS THAN 34” AND OR MORE THAN 38” MEASURED FROM FINISHED SURFACE

4 3

3

6' SIDE SETBACK F.O.F.

1011.5.2: STAIR MAX. RISER IS 7” AND MIN. IS 4” 1011.11: STAIR WAY SHALL HAVE HANDRAILS ON EACH SIDE COMPLYING WITH SECTION 10.14

4


GENERAL NOTE

ADA ACCESSIBILITY REQUIREMENTS: SEE ADA GENERAL NOTES (G 1.5, G 1.6, G 1.7)

Project Consultant Nadim Itani E-Mail: nritani@cpp.edu Structural Engineer Gary L. McGavin E-Mail: gmcgavin@cpp.edu Construction Manager Micheal Fox E-Mail: mfox@cpp.edu MEP Engineer Hofu Wu E-Mail: hwu@cpp.edu Codes Consultant Andrew Thul E-Mail: athul@cpp.edu

AREA OF FOCUS

6'-3"

ADA ACCESIBLE LOCATION ADA POSSIBLE CIRCULATION

WESLEY MASON

C.L. COL.

28'-6"

P1

10% SLOPE RUN=10'

20% SLOPE RUN=62' 7"

10% SLOPE RUN=10'

13'-6"

1

Instructor: 24'

M.E.P. ROOM

4

C.L. COL.

16

NADIM ITANI

WEST HOLLYWOOD MULTI-FAMILY HOUSING 1047 N Spaulding Ave West Hollywood, CA 90046

7'

ELEV. MECH. ROOM

VAN ACCESSIBLE ADA SPACE 11'

P2

wwmason@cpp.edu

2

3

28'-6"

NOTE: MARKED AREAS ARE ADA ACCESSIBLE UNITS OR ADA ADAPTABLE UNITS AS REQUESTED BY DWELLERS.

17

CITY OF WEST HOLLYWOOD

18

18'

34'

24'

5

20'-9"

6

C.L. COL.

7

8

9

10

12

11

13

14

15

14'

P3

No. 29'-9"

14'

PA

AREA OF FOCUS

19'-6"

PB

13'-8"

28'-6"

PD

PC

Description

Date

19'-3"

PE

PF

PG

AREA OF FOCUS 47' 8"

47' 8"

7'

18'-10"

7' 10"

5'

7'

9' 11"

32' 9"

B-B A 3.2

11'-2"

B-B A 3.2

9'-10"

6' SIDE SETBACK F.O.F.

11

17' 7"

5'

13'-6"

14'-6"

8'-10"

11

10 10' 6"

5'-8"

10

7' 6"

8 10'-2"

15' 7' 6"

15'

8

22' 5"

9

9

7 8'

8'-8"

7

6

TITLE

24'-4"

5'

14'-6"

8'-10"

25' 7"

6

5'-8"

5

5

8' 3"

4

4

4' 7' 6"

A-A A 3.1

A-A A 3.1 10'-2"

A-A A 3.1

7' 6"

A-A A 3.1

15'

19'-10" 6' SIDE SETBACK F.O.F.

16' 11"

17'

9' 8"

8' 4"

10' 4"

21'-10"

20' FRONT SETBACK F.O.F.

11'

8'-2"

8' 7"

B-B A 3.2

B-B A 3.2

Drawn by 4'-11"

15' REAR SETBACK F.O.F.

15' REAR SETBACK F.O.F.

01 9 May, 2018

Size

1

1

Job # Date

62' 4"

24 x 36 WESLEY MASON

Revision #

11'

00

20' FRONT SETBACK F.O.F.

95'

95'

A

B

C

D

E

F G

H

I

A

B

C

D

E

F G

H

G 1.4

I

Scale

6/26/2018 6:30 PM

15'

2

2

22' 5"

3

3

ADA ACCESIBILITY REQUIREMENTS


GENERAL NOTE

Project Consultant Nadim Itani E-Mail: nritani@cpp.edu Structural Engineer Gary L. McGavin E-Mail: gmcgavin@cpp.edu Construction Manager Micheal Fox E-Mail: mfox@cpp.edu MEP Engineer Hofu Wu E-Mail: hwu@cpp.edu Codes Consultant Andrew Thul E-Mail: athul@cpp.edu

WESLEY MASON

wwmason@cpp.edu

Instructor:

NADIM ITANI

WEST HOLLYWOOD MULTI-FAMILY HOUSING 1047 N Spaulding Ave West Hollywood, CA 90046 CITY OF WEST HOLLYWOOD

No.

Description

Date

TITLE

ADA GENERAL NOTES Job #

01 9 May, 2018

Size Drawn by

24 x 36 WESLEY MASON

Revision #

00

G 1.5 Scale

6/26/2018 6:30 PM

Date


GENERAL NOTE

Project Consultant Nadim Itani E-Mail: nritani@cpp.edu Structural Engineer Gary L. McGavin E-Mail: gmcgavin@cpp.edu Construction Manager Micheal Fox E-Mail: mfox@cpp.edu MEP Engineer Hofu Wu E-Mail: hwu@cpp.edu Codes Consultant Andrew Thul E-Mail: athul@cpp.edu

WESLEY MASON

wwmason@cpp.edu

Instructor:

NADIM ITANI

WEST HOLLYWOOD MULTI-FAMILY HOUSING 1047 N Spaulding Ave West Hollywood, CA 90046 CITY OF WEST HOLLYWOOD

No.

Description

Date

TITLE

ADA GENERAL NOTES Job #

01 9 May, 2018

Size Drawn by

24 x 36 WESLEY MASON

Revision #

00

G 1.6 Scale

6/26/2018 6:30 PM

Date


GENERAL NOTE

Project Consultant Nadim Itani E-Mail: nritani@cpp.edu Structural Engineer Gary L. McGavin E-Mail: gmcgavin@cpp.edu Construction Manager Micheal Fox E-Mail: mfox@cpp.edu MEP Engineer Hofu Wu E-Mail: hwu@cpp.edu Codes Consultant Andrew Thul E-Mail: athul@cpp.edu

WESLEY MASON

wwmason@cpp.edu

Instructor:

NADIM ITANI

WEST HOLLYWOOD MULTI-FAMILY HOUSING 1047 N Spaulding Ave West Hollywood, CA 90046 CITY OF WEST HOLLYWOOD

No.

Description

Date

TITLE

ADA GENERAL NOTES Job #

01 9 May, 2018

Size Drawn by

24 x 36 WESLEY MASON

Revision #

00

G 1.7 Scale

6/26/2018 6:30 PM

Date


GENERAL NOTE

Project Consultant Nadim Itani E-Mail: nritani@cpp.edu Structural Engineer Gary L. McGavin E-Mail: gmcgavin@cpp.edu Construction Manager Micheal Fox E-Mail: mfox@cpp.edu MEP Engineer Hofu Wu E-Mail: hwu@cpp.edu Codes Consultant Andrew Thul E-Mail: athul@cpp.edu

WESLEY MASON

wwmason@cpp.edu

Instructor:

NADIM ITANI

WEST HOLLYWOOD MULTI-FAMILY HOUSING 1047 N Spaulding Ave West Hollywood, CA 90046 CITY OF WEST HOLLYWOOD

No.

Description

Date

TITLE

ADA STAIR DETAILS Job #

01 9 May, 2018

Size Drawn by

24 x 36 WESLEY MASON

Revision #

00

G 1.8 Scale

6/26/2018 6:30 PM

Date


GENERAL NOTE

Project Consultant Nadim Itani E-Mail: nritani@cpp.edu Structural Engineer Gary L. McGavin E-Mail: gmcgavin@cpp.edu Construction Manager Micheal Fox E-Mail: mfox@cpp.edu MEP Engineer Hofu Wu E-Mail: hwu@cpp.edu Codes Consultant Andrew Thul E-Mail: athul@cpp.edu

WESLEY MASON

wwmason@cpp.edu

Instructor:

NADIM ITANI

WEST HOLLYWOOD MULTI-FAMILY HOUSING 1047 N Spaulding Ave West Hollywood, CA 90046 CITY OF WEST HOLLYWOOD

No.

Description

Date

TITLE

ADA ELEVATOR DETAILS Job #

01 9 May, 2018

Size Drawn by

24 x 36 WESLEY MASON

Revision #

00

G 1.9 Scale

6/26/2018 6:30 PM

Date


GENERAL NOTE

Project Consultant Nadim Itani E-Mail: nritani@cpp.edu Structural Engineer Gary L. McGavin E-Mail: gmcgavin@cpp.edu Construction Manager Micheal Fox E-Mail: mfox@cpp.edu MEP Engineer Hofu Wu E-Mail: hwu@cpp.edu Codes Consultant Andrew Thul E-Mail: athul@cpp.edu

WESLEY MASON

wwmason@cpp.edu

Instructor:

NADIM ITANI

WEST HOLLYWOOD MULTI-FAMILY HOUSING 1047 N Spaulding Ave West Hollywood, CA 90046 CITY OF WEST HOLLYWOOD

No.

Description

Date

TITLE

ADA RAMP DETAILS Job #

01 9 May, 2018

Size Drawn by

24 x 36 WESLEY MASON

Revision #

00

G 1.10 Scale

6/26/2018 6:30 PM

Date


GENERAL NOTE

Project Consultant Nadim Itani E-Mail: nritani@cpp.edu Structural Engineer Gary L. McGavin E-Mail: gmcgavin@cpp.edu Construction Manager Micheal Fox E-Mail: mfox@cpp.edu MEP Engineer Hofu Wu E-Mail: hwu@cpp.edu Codes Consultant Andrew Thul E-Mail: athul@cpp.edu

WESLEY MASON

wwmason@cpp.edu

Instructor:

NADIM ITANI

WEST HOLLYWOOD MULTI-FAMILY HOUSING 1047 N Spaulding Ave West Hollywood, CA 90046 CITY OF WEST HOLLYWOOD

No.

Description

Date

TITLE

ADA PARKING DETAILS Job #

01 9 May, 2018

Size Drawn by

24 x 36 WESLEY MASON

Revision #

00

G 1.11 Scale

6/26/2018 6:30 PM

Date


GENERAL NOTE

NOTE: ALL DIMENSIONS TO FACE OF STUD UNLESS NOTED OTHERWISE

AREA OF FOCUS

1" 47'-82

Structural Engineer Gary L. McGavin E-Mail: gmcgavin@cpp.edu

53'-4"

7'

B-B A 3.2

22'

P.L.

6' SIDE SETBACK F.O.F.

P.L.

LEGEND

31'

RAISED PLANTER 10% SLOPE RUN=10'

TEXTURED CONCRETE

13'-6"

20% SLOPE RUN=62' 7"

14'-6"

Project Consultant Nadim Itani E-Mail: nritani@cpp.edu

Construction Manager Micheal Fox E-Mail: mfox@cpp.edu MEP Engineer Hofu Wu E-Mail: hwu@cpp.edu Codes Consultant Andrew Thul E-Mail: athul@cpp.edu

6'6" EQ.

F.D.C DN

5.9% SLOPE RUN=33' 10"

DWELLING UNIT ENTRANCE

15'

19'-10"

5.2% SLOPE RUN=38' 7"

4'

5'-8"

EQ.

WOOD DECKING 1" 34'-112

WESLEY MASON

wwmason@cpp.edu

Instructor:

N. SPALDING AVE

8'-8"

14'-6"

8'

8'

100'

ALIGN

5' 8"

ALIGN

5.9% SLOPE RUN=33' 10"

DN

CITY OF WEST HOLLYWOOD

No.

Description

Date

A-A A 3.1

12'

A-A A 3.1

6' SIDE SETBACK F.O.F.

P.L.

8'-8"

B-B A 3.2 15' REAR SETBACK F.O.F.

3'

8'-4"

P.L.

20' FRONT SETBACK F.O.F.

95'

TITLE 130'

SITE PLAN

23' 7" FROM P.L. TO PARKING GRID

Job #

PF

Date

01 9 May, 2018

Size Drawn by

24 x 36 WESLEY MASON

Revision #

0' 2' 1'

00

8' 4'

A 1.1

16'

Scale

1/8" = 1-0"

6/26/2018 6:30 PM

15' FROM P.L. TO PARKING GRID

P3

19'-10"

13'

7.25% SLOPE RUN=27' 7"

WEST HOLLYWOOD MULTI-FAMILY HOUSING 1047 N Spaulding Ave West Hollywood, CA 90046

DN

DN

10'-10"

3'-6"

5'-8"

9'

UP

NADIM ITANI


GENERAL NOTE

Project Consultant Nadim Itani E-Mail: nritani@cpp.edu Structural Engineer Gary L. McGavin E-Mail: gmcgavin@cpp.edu

LEGEND DECK DRAIN 20% SLOPE RUN=62' 7"

+0.0'

10% SLOPE RUN=10'

Construction Manager Micheal Fox E-Mail: mfox@cpp.edu MEP Engineer Hofu Wu E-Mail: hwu@cpp.edu Codes Consultant Andrew Thul E-Mail: athul@cpp.edu

-4.0' 5.2% SLOPE RUN=38' 7"

-4.0'

-2.0'

5.9% SLOPE RUN=33' 10" -2.0'

-4.0'

-2.0'

WESLEY MASON

wwmason@cpp.edu

Instructor:

-2.0' -4.0'

NADIM ITANI

WEST HOLLYWOOD MULTI-FAMILY HOUSING 1047 N Spaulding Ave West Hollywood, CA 90046

-2.0'

-2.0'

-2.0' CITY OF WEST HOLLYWOOD

+0.0'

-4.0' No.

-4.0'

7.25% SLOPE RUN=27' 7"

-2.0'

Description

Date

5.9% SLOPE RUN=33' 10" -2.0'

P3 -2.0'

TITLE

SLAB PLAN PF

Job # Date

01 9 May, 2018

Size Drawn by

24 x 36 WESLEY MASON

Revision #

0' 2' 1'

00

8' 4'

A 1.2

16'

Scale

1/8" = 1-0"

6/26/2018 6:30 PM

-4.0'


GENERAL NOTE

Project Consultant Nadim Itani E-Mail: nritani@cpp.edu Structural Engineer Gary L. McGavin E-Mail: gmcgavin@cpp.edu

6'-3"

Construction Manager Micheal Fox E-Mail: mfox@cpp.edu MEP Engineer Hofu Wu E-Mail: hwu@cpp.edu

P1

28'-6"

10% SLOPE RUN=10'

20% SLOPE RUN=62' 7"

10% SLOPE RUN=10'

Codes Consultant Andrew Thul E-Mail: athul@cpp.edu

C.L. COL.

WESLEY MASON

wwmason@cpp.edu

Instructor:

NADIM ITANI

C.L. COL.

CITY OF WEST HOLLYWOOD

No.

20'-9"

Date

14'

8'

C.L. COL.

P3

Description

8'

29'-9"

14'

PA

PB

19'-6"

PC

13'-8"

PD

28'-6"

PE

TITLE

22'-7"

PF

FOUNDATION PLAN

PG

Job # Date

01 9 May, 2018

Size Drawn by

24 x 36 WESLEY MASON

Revision #

0' 2' 1'

00

8' 4'

A 1.3

16'

Scale

1/8" = 1-0"

6/26/2018 6:30 PM

P2

28'-6"

WEST HOLLYWOOD MULTI-FAMILY HOUSING 1047 N Spaulding Ave West Hollywood, CA 90046


GENERAL NOTE

AREA OF FOCUS Project Consultant Nadim Itani E-Mail: nritani@cpp.edu Structural Engineer Gary L. McGavin E-Mail: gmcgavin@cpp.edu

6'-3"

LEGEND DECK DRAIN TRENCH DRAIN

P1

28'-6"

C.L. COL.

10% SLOPE RUN=10'

13'-6"

1

20% SLOPE RUN=62' 7"

10% SLOPE RUN=10'

Construction Manager Micheal Fox E-Mail: mfox@cpp.edu MEP Engineer Hofu Wu E-Mail: hwu@cpp.edu Codes Consultant Andrew Thul E-Mail: athul@cpp.edu

2

24'

ELEV. MECH. ROOM

M.E.P. ROOM

WESLEY MASON

7'

3

wwmason@cpp.edu

4

C.L. COL.

NADIM ITANI

WEST HOLLYWOOD MULTI-FAMILY HOUSING 1047 N Spaulding Ave West Hollywood, CA 90046

VAN ACCESSIBLE ADA SPACE 11'

P2

28'-6"

Instructor:

16

17

18

CITY OF WEST HOLLYWOOD

18'

34'

24'

5

6

8

9

11

10

12

Date

13

15

14

14'

18' TYP.

7

Description

11'

18' TYP.

C.L. COL.

P3

12'-2"

18'

20'-9"

No. 9' TYP.

PA

PB

19'-6"

PC

13'-8"

PD

28'-6"

PE

TITLE

19'-3"

PF

PARKING PLAN

PG

Job # Date

01 9 May, 2018

Size Drawn by

24 x 36 WESLEY MASON

Revision #

0' 2' 1'

00

8' 4'

A 1.4

16'

Scale

1/8" = 1-0"

6/26/2018 6:30 PM

29'-9"

14'


GENERAL NOTE

NOTE: ALL DIMENSIONS TO FACE OF STUD UNLESS NOTED OTHERWISE

AREA OF FOCUS 47' 8"

9'-10"

7'

18'-10"

7' 10"

Structural Engineer Gary L. McGavin E-Mail: gmcgavin@cpp.edu

B-B A 3.2

11'-2"

6' SIDE SETBACK F.O.F.

Project Consultant Nadim Itani E-Mail: nritani@cpp.edu

Construction Manager Micheal Fox E-Mail: mfox@cpp.edu MEP Engineer Hofu Wu E-Mail: hwu@cpp.edu Codes Consultant Andrew Thul E-Mail: athul@cpp.edu

5'

13'-6"

14'-6"

8'-10"

11

10' 6"

5'-8"

10

7' 6"

9

15'

15'

8

WESLEY MASON

wwmason@cpp.edu

Instructor: 7' 6"

NADIM ITANI

WEST HOLLYWOOD MULTI-FAMILY HOUSING 1047 N Spaulding Ave West Hollywood, CA 90046 8'

8'-8"

7

CITY OF WEST HOLLYWOOD

24'-4"

5'

14'-6"

8'-10"

6

5'-8"

5

No.

Description

Date

4

A-A A 3.1

15'

A-A A 3.1

7' 6"

15'

19'-10"

2

7' 6"

3

16' 11"

17'

B-B A 3.2

6' SIDE SETBACK F.O.F.

1

9' 8"

8' 4"

10' 4"

21'-10"

20' FRONT SETBACK F.O.F.

11'

TITLE

FIRST FLOOR PLAN

95'

Job # Date

A

B

C

D

E

F G

H

01 9 May, 2018

Size

I

Drawn by

24 x 36 WESLEY MASON

Revision #

0' 2' 1'

00

8' 4'

A 1.5

16'

Scale

1/8" = 1-0"

6/26/2018 6:30 PM

15' REAR SETBACK F.O.F.


GENERAL NOTE

NOTE: ALL DIMENSIONS TO FACE OF STUD UNLESS NOTED OTHERWISE

AREA OF FOCUS 47' 8"

9' 11"

32' 9"

Project Consultant Nadim Itani E-Mail: nritani@cpp.edu Structural Engineer Gary L. McGavin E-Mail: gmcgavin@cpp.edu

B-B A 3.2

5'

7'

Construction Manager Micheal Fox E-Mail: mfox@cpp.edu

11

17' 7"

MEP Engineer Hofu Wu E-Mail: hwu@cpp.edu Codes Consultant Andrew Thul E-Mail: athul@cpp.edu

10

22' 5"

9

WESLEY MASON

10'-2"

8

wwmason@cpp.edu

Instructor:

7

NADIM ITANI

WEST HOLLYWOOD MULTI-FAMILY HOUSING 1047 N Spaulding Ave West Hollywood, CA 90046 CITY OF WEST HOLLYWOOD

25' 7"

6

5 No.

Description

Date

8' 3"

4

2 A-A A 3.1 10'-2"

A-A A 3.1

22' 5"

4'

3

8' 7"

4'-11"

15' REAR SETBACK F.O.F.

62' 4"

11' 20' FRONT SETBACK F.O.F.

95'

TITLE

SECOND FLOOR PLAN Job #

A

B

C

D

E

F G

H

Date

I

01 9 May, 2018

Size Drawn by

24 x 36 WESLEY MASON

Revision #

0' 2' 1'

00

8' 4'

A 1.6

16'

Scale

1/8" = 1-0"

6/26/2018 6:30 PM

8'-2"

B-B A 3.2

1


GENERAL NOTE

AREA OF FOCUS Project Consultant Nadim Itani E-Mail: nritani@cpp.edu Structural Engineer Gary L. McGavin E-Mail: gmcgavin@cpp.edu

LEGEND 8 A 5.2

20.32% SLOPE RUN=33'

9 A 5.2

HVAC CORRUGATED METAL ROOFING

20.32% SLOPE RUN=34.5'

SKYLIGHT

Construction Manager Micheal Fox E-Mail: mfox@cpp.edu MEP Engineer Hofu Wu E-Mail: hwu@cpp.edu Codes Consultant Andrew Thul E-Mail: athul@cpp.edu

ROOF VENT 16.57% SLOPE RUN=69.5'

10.45% SLOPE RUN=106' WESLEY MASON

wwmason@cpp.edu

Instructor:

NADIM ITANI

WEST HOLLYWOOD MULTI-FAMILY HOUSING 1047 N Spaulding Ave West Hollywood, CA 90046 CITY OF WEST HOLLYWOOD

19.29% SLOPE RUN=34.5'

20.32% 20 32% % SLOPE RUN=33' RUN RUN=33 33' 33 SKYLIGHT

16.57% 16 57% SLOPE RUN=69.5' RUN=69 RUN 69 69.5 5 5'

No.

Description

Date

10.45% SLOPE RUN=106'

TITLE

ROOF PLAN Job # Date

01 9 May, 2018

Size Drawn by

24 x 36 WESLEY MASON

Revision #

1'

00

8' 4'

A 1.7

16'

Scale

1/8" = 1-0"

6/26/2018 6:30 PM

0' 2'


GENERAL NOTE

I

P.L.

H

F

G

E

D C

B

A

P.L.

P.L.

11

10

9

8

7

6

5

4

3

2

1

P.L.

Project Consultant Nadim Itani E-Mail: nritani@cpp.edu Structural Engineer Gary L. McGavin E-Mail: gmcgavin@cpp.edu Construction Manager Micheal Fox E-Mail: mfox@cpp.edu MEP Engineer Hofu Wu E-Mail: hwu@cpp.edu Codes Consultant Andrew Thul E-Mail: athul@cpp.edu

NORTH ELEVATION

WEST ELEVATION

WESLEY MASON

wwmason@cpp.edu

Instructor:

NADIM ITANI

WEST HOLLYWOOD MULTI-FAMILY HOUSING 1047 N Spaulding Ave West Hollywood, CA 90046 CITY OF WEST HOLLYWOOD

A

B

C

D

E

F G

H

I

P.L.

P.L.

1

2

3

4

5

6

7

8

9

10

11

P.L.

No.

SOUTH ELEVATION

Description

Date

EAST ELEVATION TITLE

ELEVATIONS Job # Date

01 9 May, 2018

Size Drawn by

24 x 36 WESLEY MASON

Revision #

0' 2' 1'

A 2.1

8' 4'

00

16' Scale

1/8" = 1-0"

6/26/2018 6:30 PM

P.L.


GENERAL NOTE

Project Consultant Nadim Itani E-Mail: nritani@cpp.edu Structural Engineer Gary L. McGavin E-Mail: gmcgavin@cpp.edu Construction Manager Micheal Fox E-Mail: mfox@cpp.edu MEP Engineer Hofu Wu E-Mail: hwu@cpp.edu Codes Consultant Andrew Thul E-Mail: athul@cpp.edu

WESLEY MASON

wwmason@cpp.edu

Instructor:

NADIM ITANI

WEST HOLLYWOOD MULTI-FAMILY HOUSING 1047 N Spaulding Ave West Hollywood, CA 90046 CITY OF WEST HOLLYWOOD

P.L.

P.L.

No.

Description

Date

SECOND FLOOR +28' 6"

SECOND FLOOR +9' 4"

TITLE

LONGITUDINAL SECTION

FINISHED FLOOR -4' 0"

Job # Date

01 9 May, 2018

Size Drawn by

PARKING -13' 0"

24 x 36 WESLEY MASON

Revision #

0' 2' 1'

A 3.1

8' 4'

00

16' Scale

1/8" = 1-0"

6/26/2018 6:30 PM

GRADE +0' 0"


GENERAL NOTE

Project Consultant Nadim Itani E-Mail: nritani@cpp.edu Structural Engineer Gary L. McGavin E-Mail: gmcgavin@cpp.edu Construction Manager Micheal Fox E-Mail: mfox@cpp.edu MEP Engineer Hofu Wu E-Mail: hwu@cpp.edu Codes Consultant Andrew Thul E-Mail: athul@cpp.edu

WESLEY MASON

wwmason@cpp.edu

Instructor:

NADIM ITANI

WEST HOLLYWOOD MULTI-FAMILY HOUSING 1047 N Spaulding Ave West Hollywood, CA 90046 CITY OF WEST HOLLYWOOD

No.

Description

Date

TITLE

CROSS SECTION Job #

01 9 May, 2018

Size Drawn by

24 x 36 WESLEY MASON

Revision #

0' 2' 1'

A 3.2

8' 4'

00

16' Scale

1/8" = 1-0"

6/26/2018 6:30 PM

Date


GENERAL NOTE

A

B

D

C

E

1" 47'-82 11" 8'-016

5'

Project Consultant Nadim Itani E-Mail: nritani@cpp.edu

3'

11

Structural Engineer Gary L. McGavin E-Mail: gmcgavin@cpp.edu

3'

W-E

10'

8'

D-3

Construction Manager Micheal Fox E-Mail: mfox@cpp.edu

13'-10"

W-F

MEP Engineer Hofu Wu E-Mail: hwu@cpp.edu

10'-2"

D-2

5'-2"

7' 5"

Codes Consultant Andrew Thul E-Mail: athul@cpp.edu

3'-8"

D-2

10 5'

10' 2"

10' 9"

SECOND FLOOR PLAN WESLEY MASON

wwmason@cpp.edu

Instructor:

NADIM ITANI

WEST HOLLYWOOD MULTI-FAMILY HOUSING 1047 N Spaulding Ave West Hollywood, CA 90046 CITY OF WEST HOLLYWOOD

A

B

D

C

E

1" 47'-82 1" 7'-102

11'-2"

11

No.

D-4

WC-2

Description

Date

WC-1

14'-6"

13'-10"

W-D

5'-2"

D-2

D-3 D-2

6'

10 5'-2"

D-3

5'-10"

5'-10"

W-D

D-1

TITLE

ENLARGED PLANS 8'-6"

18' 3"

Job #

10' 6"

Date

01 9 May, 2018

Size 39' 11"

Drawn by

24 x 36 WESLEY MASON

Revision #

FIRST FLOOR PLAN 0'

2' 1'

A 4.1

8' 4'

00

16' Scale

1/4" = 1-0"

6/26/2018 6:30 PM

10' 8"


GENERAL NOTE

Project Consultant Nadim Itani E-Mail: nritani@cpp.edu Structural Engineer Gary L. McGavin E-Mail: gmcgavin@cpp.edu

5'

MEP Engineer Hofu Wu E-Mail: hwu@cpp.edu

4' 5"

1' 7"

DW

Construction Manager Micheal Fox E-Mail: mfox@cpp.edu

Codes Consultant Andrew Thul E-Mail: athul@cpp.edu

2' 3"

2' 11"

1'-6"

4'

2' 4"

2' 4"

1'-3"

B A C

2' 2"

WESLEY MASON

wwmason@cpp.edu

Instructor: 1' 3"

4"

NADIM ITANI

WEST HOLLYWOOD MULTI-FAMILY HOUSING 1047 N Spaulding Ave West Hollywood, CA 90046 CITY OF WEST HOLLYWOOD

3'-4"

2'

8'

No.

Description

Date

TITLE

ENLARGED PLAN SECTION Job # Date

01 9 May, 2018

Size Drawn by

24 x 36 WESLEY MASON

Revision #

00

A 4.2 Scale

3/4" = 1-0"

6/26/2018 6:30 PM

WASHER/ DRYER

B A C


CORRUGATED METAL ROOFING

GENERAL NOTE

6" PARAPIT METAL COPING BLOCKING BETWEEN FLOOR JOISTS 7 A 5.2

SPECIFIC NOTE

TOP OF ROOF +19'6'

1 A 5.1

SKYLIGHT

P.L.

GLULAM BEAM

Structural Engineer Gary L. McGavin E-Mail: gmcgavin@cpp.edu

BLOCKING 5 8"

POLISHED LIGHTWEIGHT CONCRETE FLOOR 5 8"

Construction Manager Micheal Fox E-Mail: mfox@cpp.edu

2x12 TRUS JOIST

2x6 WOOD STUDS @16" O.C.

GYPSUM BOARD

2x6 WOOD STUDS @16" O.C.

PLYWOOD DIAPRAGM

5 8"

BOTTOM PLATE

Project Consultant Nadim Itani E-Mail: nritani@cpp.edu

PLYWOOD SHEATHING

WATERPROOFING MEMBRANE

MEP Engineer Hofu Wu E-Mail: hwu@cpp.edu Codes Consultant Andrew Thul E-Mail: athul@cpp.edu

SECOND LEVEL +9'6'

2 A 5.1

FACADE HANGER RAIL CORRUGATED METAL RAINSCREEN

DOUBLE TOP PLATE

WESLEY MASON

wwmason@cpp.edu

Instructor:

2x12 TRUS JOIST

BLOCKING BETWEEN FLOOR JOISTS

DROP CEILING POLISHED LIGHTWEIGHT CONCRETE FLOOR

3 A 5.1

NADIM ITANI

DOUBLE TOP PLATE

WEST HOLLYWOOD MULTI-FAMILY HOUSING 1047 N Spaulding Ave West Hollywood, CA 90046

RECESSED SLIDING GLASS DOOR

CITY OF WEST HOLLYWOOD

GRADE +0' 0"

No.

Description

Date

WOOD DECKING ON RAISED PEDESTAL SYSTEM DECK DRAIN CONCRETE RETAINING WALL WATERPROOFING MEMEBRANE SAND GRAVEL DRAIN PIPE

TITLE

KEY WALL SECTION 1 Job # Date

01 9 May, 2018

Size Drawn by

24 x 36 WESLEY MASON

Revision #

0'

2' 1'

00

A 4.3

8' 4' Scale

1/2" = 1-0"

6/26/2018 6:30 PM

PARKING -13' 0"


TOP OF ROOF +28' 0"

GENERAL NOTE

METAL COPING 5 8"

PLYWOOD DIAPRAGM

CORRUGATED METAL ROOFING HVAC UNITS (BEYOND) DROP CEILING CORRUGATED METAL RAINSCREEN WATERPROOFING MEMBRANE 5 8"

PLYWOOD SHEATHING

2x6 STUDS @ 16" O.C. BLOCKING 5 8"

GYPSUM BOARD

POLISHED LIGHTWEIGHT CONCRETE FLOOR 5 8"

PLYWOOD DIAPHRAGM

Project Consultant Nadim Itani E-Mail: nritani@cpp.edu Structural Engineer Gary L. McGavin E-Mail: gmcgavin@cpp.edu Construction Manager Micheal Fox E-Mail: mfox@cpp.edu MEP Engineer Hofu Wu E-Mail: hwu@cpp.edu Codes Consultant Andrew Thul E-Mail: athul@cpp.edu

2x12 TRUS JOIST @ 24" O.C. BLOCKING BETWEEN FLOOR JOISTS

SECOND LEVEL +9'6' WESLEY MASON

wwmason@cpp.edu

Instructor:

JOIST HANGER FACADE HANGER RAIL

11 A 5.2

NADIM ITANI

WEST HOLLYWOOD MULTI-FAMILY HOUSING 1047 N Spaulding Ave West Hollywood, CA 90046 CITY OF WEST HOLLYWOOD

DOUBLE TOP PLATE LIGHT SHELF

GRADE +0' 0"

No.

Description

Date

RECESSED SINGLE PANE LAMINATED LOW E GLASS POLISHED LIGHTWEIGHT CONCRETE FLOOR FINISHED FLOOR -4' 0"

SAND GRAVEL TITLE

KEY WALL SECTION 2 Job #

01 9 May, 2018

Size Drawn by

24 x 36 WESLEY MASON

Revision #

0'

2' 1'

8'

PARKING -13' 0"

00

A 4.4

4' Scale

1/2" = 1-0"

6/26/2018 6:30 PM

Date


GENERAL NOTE

Project Consultant Nadim Itani E-Mail: nritani@cpp.edu Structural Engineer Gary L. McGavin E-Mail: gmcgavin@cpp.edu Construction Manager Micheal Fox E-Mail: mfox@cpp.edu

2'-7" 2'-3"

Codes Consultant Andrew Thul E-Mail: athul@cpp.edu

4"

DW

3'

3'

6'

2'-3"

2'-7"

1'-10"

MEP Engineer Hofu Wu E-Mail: hwu@cpp.edu

3" 1'-4"

WESLEY MASON

wwmason@cpp.edu

Instructor:

NADIM ITANI

WEST HOLLYWOOD MULTI-FAMILY HOUSING 1047 N Spaulding Ave West Hollywood, CA 90046

A

INTERIOR ELEVATION A SCALE 1/2"= 1'

B

INTERIOR ELEVATION B SCALE 1/2"= 1'

CITY OF WEST HOLLYWOOD

Description

Date

2'-3"

2'-7"

No.

2'-6"

3"

3"

A

INTERIOR ELEVATION C SCALE 1/2"= 1'

KITCHEN INTERIOR ELEVATIONS

Job # Date

01 9 May, 2018

Size Drawn by

24 x 36 WESLEY MASON

Revision #

0'

2' 1'

00

A 4.5

8' 4' Scale

1/2" = 1-0"

6/26/2018 6:30 PM

TITLE


GENERAL NOTE

Project Consultant Nadim Itani E-Mail: nritani@cpp.edu Structural Engineer Gary L. McGavin E-Mail: gmcgavin@cpp.edu Construction Manager Micheal Fox E-Mail: mfox@cpp.edu

2'-7" 2'-3"

Codes Consultant Andrew Thul E-Mail: athul@cpp.edu

4"

3'

DW

3'

6'

2'-3"

2'-7"

1'-10"

MEP Engineer Hofu Wu E-Mail: hwu@cpp.edu

3" 1'-4"

WESLEY MASON

wwmason@cpp.edu

Instructor:

NADIM ITANI

WEST HOLLYWOOD MULTI-FAMILY HOUSING 1047 N Spaulding Ave West Hollywood, CA 90046

INTERIOR ELEVATION A SCALE 1/2"= 1'

B

INTERIOR ELEVATION B SCALE 1/2"= 1'

CITY OF WEST HOLLYWOOD

No.

TITLE

A

INTERIOR ELEVATION C SCALE 1/2"= 1'

Description

Date

BATHROOM INTERIOR ELEVATIONS

Job # Date

01 9 May, 2018

Size Drawn by

24 x 36 WESLEY MASON

Revision #

0'

2' 1'

00

A 4.6

8' 4' Scale

1/2" = 1-0"

6/26/2018 6:30 PM

A


GENERAL NOTE

A

B EQ.

4'-6"

D

C EQ.

E

HEIGHT VARIES SEE INT. ELEV.

1'

SPECIFIC NOTE

11

EXHAUST FAN PENDANT LIGHT

4'

RECESSED DOWN LIGHT TASK LIGHT

+7'10" 6'

WALL WASHING ACCENT LIGHT

2'

RECESSED ACCENT LIGHT EXTERIOR WALL MOUNTED LIGHT

10 HEIGHT VARIES SEE INT. ELEV.

5'-6"

1'

SECOND CEILING PLAN WESLEY MASON

wwmason@cpp.edu

Instructor:

NADIM ITANI

WEST HOLLYWOOD MULTI-FAMILY HOUSING 1047 N Spaulding Ave West Hollywood, CA 90046 CITY OF WEST HOLLYWOOD

A

B

D

C

E No.

4'

3'

2'

Description

Date

HEIGHT VARIES SEE INT. ELEV.

2'

11 +7'10"

6'

+7'10"

3'-6"

4'

4'

4' 1" 5'-14

10

4'

TITLE

CEILING PLANS

+7'10" 1" 5'-14

3' 11"

Job # Date

01 9 May, 2018

Size Drawn by

24 x 36 WESLEY MASON

Revision # 3'

5'

EQ.

0'

2' 1'

A 4.7

8' 4'

00

5'

FIRST CEILING PLAN 16' Scale

1/4" = 1-0"

6/26/2018 6:30 PM

2'

3'-10"

4'

ALIGN

2'

+7'10" +7'10"


GENERAL NOTE

11

E

10

D

B

C

A Project Consultant Nadim Itani E-Mail: nritani@cpp.edu Structural Engineer Gary L. McGavin E-Mail: gmcgavin@cpp.edu

TOP OF ROOF +9'6'

TOP OF ROOF +9'6'

Construction Manager Micheal Fox E-Mail: mfox@cpp.edu MEP Engineer Hofu Wu E-Mail: hwu@cpp.edu

D-3

SECOND LEVEL CEILING +16' 8"

Codes Consultant Andrew Thul E-Mail: athul@cpp.edu

10 A 5.2

SECOND LEVEL CEILING +16' 8" W-F

W-E

SECOND LEVEL +9' 6"

W-D

SECOND LEVEL +9' 6"

WESLEY MASON

D-3 6 A 5.1

WC-1

5 A 5.1

D-4

GRADE +0' 0"

NADIM ITANI

WEST HOLLYWOOD MULTI-FAMILY HOUSING 1047 N Spaulding Ave West Hollywood, CA 90046 CITY OF WEST HOLLYWOOD

4 A 5.1

GRADE +0' 0"

wwmason@cpp.edu

Instructor:

WC-2

11 No.

Description

Date

TOP OF ROOF +9'6'

SECOND LEVEL CEILING +16' 8"

TITLE

ENLARGED ELEVATIONS

SECOND LEVEL +9' 6" Job # Date

01 9 May, 2018

Size Drawn by

24 x 36 WESLEY MASON

Revision #

00

A 4.8

GRADE +0' 0" Scale

1/4" = 1-0"

6/26/2018 6:30 PM

10


GENERAL NOTE

CORRUGATED METAL ROOFING WATERPROOFING MEMBRANE

PRE-FINISHED MTL COPING CAP 3" 8

2"

5"

PLYWOOD DIAPHRAGM

CORRUGATED METAL RAINSCREEN

RECESSED SLIDING GLASS DOOR POLISHED LIGHTWEIGHT CONCRETE FLOOR

DOUBLE TOP PLATE (3) 41" THERMAL ISOLATOR SHIMS HORIZONTAL AT EACH FASTENER LOCATION

ADJUSTABLE BRACKET HANGER RAIL (FIELD INSTALLED) (3) 41" THERMAL ISOLATOR SHIMS HORIZONTAL AT EACH FASTENER LOCATION

RAISED FLOOR PEDASTAL SYSTEM WOOD DECKING

REINFORCED CONCRETE DECK ABOVE PARKING (2% SLOPE)

ADJUSTABLE BRACKET HANGER RAIL (FIELD INSTALLED)

WOOD STUDS 16" O.C. PLYWOOD SHEATHING

Structural Engineer Gary L. McGavin E-Mail: gmcgavin@cpp.edu Construction Manager Micheal Fox E-Mail: mfox@cpp.edu MEP Engineer Hofu Wu E-Mail: hwu@cpp.edu Codes Consultant Andrew Thul E-Mail: athul@cpp.edu

RECESSED SLIDING GLASS DOOR

WATERPROOFING MEMBRANE

Project Consultant Nadim Itani E-Mail: nritani@cpp.edu

2"

CORRUGATED METAL RAINSCREEN

COUNTERFLASHING

VERTICLE WEEP SCREEN

1" 32

WESLEY MASON

wwmason@cpp.edu

Instructor:

1

ROOF PARAPIT CAP SCALE 3"= 1'

2

WINDOW HEAD SCALE 3"= 1'

3

WINDOW FLOOR SCALE 3"= 1'

NADIM ITANI

WEST HOLLYWOOD MULTI-FAMILY HOUSING 1047 N Spaulding Ave West Hollywood, CA 90046 CITY OF WEST HOLLYWOOD

ADJUSTABLE BRACKET HANGER RAIL (FIELD INSTALLED) 4"

WOOD STUDS 16" O.C. INTERIOR FINISH

No.

PLYWOOD SHEATHING WATERPROOFING MEMBRANE

CORRUGATED METAL RAINSCREEN STEEL COVER

COUNTERFLASHING

3"

5"

1'-33 4"

CONCRETE CURB

FLOOR SCALE 3"= 1'

Date

SINGLE PANE LAMINATED LOW E GLASS

VERTICLE WEEP SCREEN

4

Description

STEEL FRAME

WOOD STUDS 16" O.C.

ANCHOR BOLT

HANGER RAIL

REINFORCED CONCRETE DECK ABOVE PARKING (2% SLOPE)

PANEL BRACKET

CORRUGATED METAL RAINSCREEN

TITLE

KEY DETAILS

5"

HANGER RAIL Job #

PANEL BRACKET

Date

01 9 May, 2018

Size

PANEL FASTENER

PANEL FASTENER

Drawn by

24 x 36 WESLEY MASON

Revision #

CORRUGATED METAL RAINSCREEN

5

RAINSCREEN MIDPANEL SCALE 3"= 1'

00

A 5.1 6

RAINSCREEN TO WINDOW VERTICLE CONNECTION SCALE 3"= 1'

Scale

3" = 1-0"

6/26/2018 6:30 PM

1'-4"

(3) 41" THERMAL ISOLATOR SHIMS HORIZONTAL AT EACH FASTENER LOCATION

SILICONE SEAL

HANGER RAIL FASTENER


GENERAL NOTE

CUSTOM STEEL DOWNSPOUT PRIMARY DOWNSPOUT 3" DIAMETER

OVERFLOW DOWNSPOUT 3" DIAMETER CORRUGATED METAL RAINSCREEN (BELOW)

T.J.I. @ 24" O.C.

TIGHT JOINT BETWEEN FINISH GROOVE AND FINISH MATERIAL

WOOD SLEEPERS

PARAPIT CAP

Project Consultant Nadim Itani E-Mail: nritani@cpp.edu

1'

1'

CORRUGATED METAL ROOFING

PLYWOOD DIAPHRAGM

Structural Engineer Gary L. McGavin E-Mail: gmcgavin@cpp.edu

5 21"

WATERPROOF MEMBRANE

METAL GUTTER 2% SLOPE

6 21" AWAY FROM EDGE OF WALL

CORRUGATED METAL ROOFING

3" AWAY FROM EDGE OF RAINSCREEN

FIXED SKYLIGHT

CORRUGATED METAL ROOFING

Construction Manager Micheal Fox E-Mail: mfox@cpp.edu

PARAPIT BLOCKING BETWEEN T.J.I. @ 24" O.C.

METAL GUTTER

PLYWOOD DIAPHRAGM

GLULAM BEAM

MEP Engineer Hofu Wu E-Mail: hwu@cpp.edu Codes Consultant Andrew Thul E-Mail: athul@cpp.edu

GLULAM BEAM INTERIOR FINISH

2% SLOPE

INTERIOR FINISH

WESLEY MASON

wwmason@cpp.edu

Instructor:

7

SKYLIGHT SCALE 3"= 1'

8

DOWNSPOUT TOP SCALE 3"= 1'

9

DOWNSPOUT 1 SCALE 3"= 1'

NADIM ITANI

WEST HOLLYWOOD MULTI-FAMILY HOUSING 1047 N Spaulding Ave West Hollywood, CA 90046 CITY OF WEST HOLLYWOOD

CORRUGATED METAL ROOFING

METAL FRAME BOOT PRE-FINISHED MTL COPING CAP

METAL COPING

POLISHED LIGHTWEIGHT CONCRETE FLOOR

POLISHED LIGHTWEIGHT CONCRETE FLOOR

5 8"

PLYWOOD

No.

Description

Date

1" 14

CUSTOM METAL DOWNSPOUT GUTTTER 2% SLOPE

1" 32

2x12 FLOOR JOISTS

WOOD STUDS 16" O.C. PLYWOOD SHEATHING

2x12 STAIR STRINGER

WATERPROOFING MEMBRANE

DOWNSPOUT 2 SCALE 3"= 1'

TITLE

KEY DETAILS Job # Date

DOUBLE TOP PLATE

CORRUGATED METAL RAINSCREEN

10

JOIST HANGER AT EACH STRINGER

01 9 May, 2018

Size Drawn by

24 x 36 WESLEY MASON

Revision #

00

A 5.2 11

GLASS HANDRAIL SCALE 3"= 1'

12

STAIR/LANDING CONNECTION SCALE 3"= 1'

Scale

3" = 1-0"

6/26/2018 6:30 PM

3"


GENERAL NOTE

METAL FRAME BOOT

GLASS HANDRAIL

5 8"

CAP RAIL

STEEL SUPPORT WELDED TO METAL PLATE

PLYWOOD

5 8"

11"

POLISHED LIGHTWEIGHT CONCRETE FLOOR

PLYWOOD

1"

2x12 FLOOR JOISTS @ 24" O.C.

1"

GLASS HANDRAIL

Project Consultant Nadim Itani E-Mail: nritani@cpp.edu Structural Engineer Gary L. McGavin E-Mail: gmcgavin@cpp.edu Construction Manager Micheal Fox E-Mail: mfox@cpp.edu

2x12 STRINGER

MEP Engineer Hofu Wu E-Mail: hwu@cpp.edu

7"

EXPANSION BOLT

Codes Consultant Andrew Thul E-Mail: athul@cpp.edu

POLISHED LIGHTWEIGHT CONCRETE FLOOR 2x12 STAIR STRINGER

JOIST HANGER AT EACH STRINGER

DOUBLE TOP PLATE WESLEY MASON

wwmason@cpp.edu

Instructor:

13

BASE STIAR CONNECTION SCALE 3"= 1'

14

LANDING SCALE 1 1/2"= 1'

15

GLASS HANDRAIL STAIR SCALE 3"= 1'

NADIM ITANI

WEST HOLLYWOOD MULTI-FAMILY HOUSING 1047 N Spaulding Ave West Hollywood, CA 90046 CITY OF WEST HOLLYWOOD

GLASS HANDRAIL

5 8"

PLYWOOD

No.

Description

Date

2x12 STRINGER

TITLE

Job # Date

01 9 May, 2018

Size Drawn by

24 x 36 WESLEY MASON

Revision #

00

A 5.2 16

GLASS HANDRAIL STAIR CONNECTION SCALE 3"= 1'

Scale

3" = 1-0"

6/26/2018 6:30 PM

METAL FRAME BOOT WELDED TO METAL PLATE

KEY DETAILS


GENERAL NOTE

DOOR SCHEDULE STACKED UNIT

WINDOW SCHEDULE STACKED UNIT

DOOR

FRAME

1

TYPE

1

D-1

2

D-2

3

D-3

4

D-4

WIDTH 3' 0" 3' 0" 5' 0" 4' 0"

HEIGHT 7' 6" 7' 0" 7' 0" 7' 0"

3'

THICKNESS

MATERIAL

FINISH

SCREEN

MATERIAL

FINISH

0' 1

3 4"

METAL

STEEL

N

METAL

0' 1

3 4"

WOOD

PAINT

N

0' 1

3 4"

GLASS

CLEAR/ OPAQUE

0' 1

3 4"

GLASS

CLEAR/ OPAQUE

3'

WINDOW

DOOR

FRAME

1

TYPE

WIDTH

HEIGHT

MATERIAL

FINISH

MATERIAL

STEEL

1

W-A

4' 0"

7' 8"

GLASS

CLEAR/ OPAQUE

STEEL/ SILICONE

WOOD

PAINT

2

W-B

4' 0"

7' 0"

GLASS

CLEAR/ OPAQUE

STEEL/ SILICONE

N

METAL

STEEL

3

W-C

2' 0"

7' 0"

GLASS

CLEAR/ OPAQUE

STEEL/ SILICONE

N

METAL

STEEL

4

W-D

8' 0"

7' 0"

GLASS

CLEAR/ OPAQUE

STEEL

5

W-E

10' 0"

6' 0"

GLASS

CLEAR/ OPAQUE

STEEL

6

W-F

6' 0"

7' 0"

GLASS

CLEAR/ OPAQUE

STEEL

5'

4'-1"

Project Consultant Nadim Itani E-Mail: nritani@cpp.edu Structural Engineer Gary L. McGavin E-Mail: gmcgavin@cpp.edu

4'-1"

Construction Manager Micheal Fox E-Mail: mfox@cpp.edu

2'-1"

MEP Engineer Hofu Wu E-Mail: hwu@cpp.edu

SILICONE SEAL BETWEEN WINDOWS 2' 7'

7'-8"

4' 7'

7'

7'-3"

7'

7'-03 4"

4'

7'-9"

7'-6"

Codes Consultant Andrew Thul E-Mail: athul@cpp.edu

STEEL FRAME (RECESSED)

3'-6"

1

D-1 SCALE 21"= 1'

2

WESLEY MASON

1" 5'-12

3'-6"

D-2 SCALE 21"= 1'

3

wwmason@cpp.edu

Instructor:

D-3 SCALE 21"= 1'

1

W-A SCALE 21"= 1'

2

W-B SCALE 21"= 1'

3

W-C SCALE 21"= 1'

NADIM ITANI

WEST HOLLYWOOD MULTI-FAMILY HOUSING 1047 N Spaulding Ave West Hollywood, CA 90046 CITY OF WEST HOLLYWOOD

1" 8'-14

4'

1" 10'-12

6'-1 21"

Description

Date

6'

No.

7'

7'

7'-03 4"

8' 10'

6'

1" 4'-12

D-4 SCALE 21"= 1'

4

W-D SCALE 21"= 1'

5

W-E SCALE 21"= 1'

6

W-F SCALE 21"= 1'

TITLE

SCHEDULES Job # Date

01 9 May, 2018

Size Drawn by

24 x 36 WESLEY MASON

Revision #

00

A 6.1 Scale

6/26/2018 6:30 PM

4


GENERAL NOTE

WINDOW UNIT COMBINATION LEGEND WINDOW 1

TYPE

COMBINATION

TOTAL WIDTH

1

WC-1

W-A + W-A + W-A + W-A

16'

2

WC-2

W-B + W-B + W-C

10'

Project Consultant Nadim Itani E-Mail: nritani@cpp.edu Structural Engineer Gary L. McGavin E-Mail: gmcgavin@cpp.edu 4'

4'

4'

4'

4'

4'

2'

Construction Manager Micheal Fox E-Mail: mfox@cpp.edu MEP Engineer Hofu Wu E-Mail: hwu@cpp.edu

W-A

W-A

Codes Consultant Andrew Thul E-Mail: athul@cpp.edu

10' 7'

16'

SILICONE SEAL BETWEEN WINDOWS

W-A

7'-8"

W-A

STEEL FRAME (RECESSED) WESLEY MASON

wwmason@cpp.edu

Instructor:

1

WC-2 SCALE 21"= 1'

WEST HOLLYWOOD MULTI-FAMILY HOUSING 1047 N Spaulding Ave West Hollywood, CA 90046 CITY OF WEST HOLLYWOOD

No.

Description

Date

TITLE

SCHEDULES Job # Date

01 9 May, 2018

Size Drawn by

24 x 36 WESLEY MASON

Revision #

00

A 6.2 Scale

6/26/2018 6:30 PM

1

WC-1 SCALE 21"= 1'

NADIM ITANI


GENERAL NOTE

12 A 5.2

SPECIFIC NOTE 3'

DN

11"

16 A 5.3

13'-103 4"

13 A 5.3

STAIR PLAN SCALE 1/2"= 1'

STAIR SECTION SCALE 1/2"= 1'

WESLEY MASON

wwmason@cpp.edu

Instructor:

NADIM ITANI

WEST HOLLYWOOD MULTI-FAMILY HOUSING 1047 N Spaulding Ave West Hollywood, CA 90046 CITY OF WEST HOLLYWOOD

No.

Description

Date

LEVEL 2 +9' 6"

15 A 5.3 13 A 5.3

TITLE

VERTICLE CIRCULATION Job #

01 9 May, 2018

7"

Size

LEVEL 1 +0'0"

Drawn by

24 x 36 WESLEY MASON

Revision #

00

A 7.1 STAIR ELEVATION SCALE 1/2"= 1'

Scale

1/2" = 1-0"

6/26/2018 6:30 PM

34"

Date


GENERAL NOTE

+17.5’ ROOF +9.0’ SECOND FLOOR 2x6 STACKED 6” PARAPIT -4.0’ FLOOR

2x12 STAGGERED BLOCKING @ 8’ (O.C. typ.) 2x12 JOISTS @ 24” (O.C. typ.)

5/8” PLYWOOD SHEAR PANEL

2x6 STUDS @ 16” (O.C. typ.) 2x12 JOISTS @ 24” (O.C. typ.)

3/4” PLYWOOD DIAPHRAGM 8’

6x12 HEADER 4’

2x6 CRIPPLE STUD

1’

2x6 KING STUD Wesley Mason

2x6 TRIMMER (typ.)

4x6 KING STUD

2x6 SILL PLATE

5/8” PLYWOOD SHEAR PANEL

wwmason@cpp.edu

Instructor:

Nadim Itani

West Hollywood Multi-Family Housing 1047 N Spaulding Ave West Hollywood, CA 90046

4’ 1’

0’

2’

8’

City of West Hollywood

No.

Description

Date

TITLE

Structural Wall Section Job #

S-1B Arc 472

Date

26 March, 2018

Size Drawn by

24 x 36 Wesley Mason

Revi sion #

00

S 1B.1

-13.0’ PARKING Scale

1/16” = 1’

6/26/2018 6:30 PM

2x6 TRIMMER (typ.)

6x10 HEADER

2’ 0’

2x6 BOTTOM PLATE (typ.)

SPECIFIC NOTE


GENERAL NOTE

STACK SELECTION SPECIFIC NOTE

SHEAR WALLS BRACED FRAME

47' 8"

47' 8"

11

10 10'-6"

5'-8"

10

14'-6"

14'-6"

11

9 19'-10"

Wesley Mason

wwmason@cpp.edu

Instructor:

8 15'

8

9

Nadim Itani

West Hollywood Multi-Family Housing 1047 N Spaulding Ave West Hollywood, CA 90046

7 8'

6 14'-6"

13'-10"

6

4 3

No.

Description

Date

2 15'

1

1

95'

A

B

C

D

95'

E

F G

H

I

A

B

C

D

E

F G

H

I

TITLE

FIRST FLOOR PLAN

SECOND FLOOR PLAN

SCALE: 3/32” = 1’

SCALE: 3/32” = 1’

SHEAR LAYOUT FLOORPLANS Job # Date

16 April, 2018

Size Drawn by

24 x 36 Wesley Mason

Revi sion #

01

S-3.1 Scale

3/16” = 1’

6/26/2018 6:30 PM

2

19'-10"

4 3

11'-2"

5

5'-8"

5

City of West Hollywood

8'

7


GENERAL NOTE

SHEAR PANELS

BRACED FRAME SPECIFIC NOTE

E

D

B

C

A

10

11

TOP OF ROOF 25’

TOP OF ROOF 25’

LOWEST CEILING 16’ 8”

LOWEST CEILING 16’ 8”

FIRST FLOOR 9’ 4”

FIRST FLOOR 9’ 4”

GRADE 0’ 0”

GRADE 0’ 0”

Wesley Mason

wwmason@cpp.edu

Instructor:

Nadim Itani

West Hollywood Multi-Family Housing 1047 N Spaulding Ave West Hollywood, CA 90046 City of West Hollywood

No.

B

C

D

E

11

Date

10

TOP OF ROOF 25’

TOP OF ROOF 25’

LOWEST CEILING 16’ 8”

LOWEST CEILING 16’ 8”

FIRST FLOOR 9’ 4”

FIRST FLOOR 9’ 4”

TITLE

SHEAR LAYOUT ELEVATIONS Job # Date

16 April, 2018

Size Drawn by

24 x 36 Wesley Mason

Revi sion #

GRADE 0’ 0” 0’

2’ 1’

GRADE 0’ 0”

01

S-3.2

8’ 4’

16’

Scale

3/16” = 1’

6/26/2018 6:30 PM

A

Description


GENERAL NOTE

SHEAR PANELS DIAPRHAGM

SPECIFIC NOTE

Wesley Mason

wwmason@cpp.edu

Instructor:

Nadim Itani

West Hollywood Multi-Family Housing 1047 N Spaulding Ave West Hollywood, CA 90046 City of West Hollywood

B

E D

C

No.

10

Description

Date

C D 11

E

B

11 10

TITLE

SHEAR LAYOUT AXON Job # 16 April, 2018

Size

0’ 1’

Drawn by

2’

8’ 4’

24 x 36 Wesley Mason

Revi sion #

16’

01

S-3.3 Scale

3/16” = 1’

6/26/2018 6:30 PM

Date


HW HW

GAS

HW HW HW HW HW HW

HW

HW

Proposed Gas Line Proposed Water Line Proposed Sewer Line to Basement MEP Room

HW

GAS

HW

GAS

HW

GAS

HW

GAS

HW

GAS

HW

GAS

HW

GAS

GAS

GAS

GAS

GAS

GAS

5'

SPECIFIC NOTE

HW

GAS

GAS

Proposed Electricity Transformer

HW

GAS

GAS

HW

GAS

HW

GAS

HW

GAS

GENERAL NOTE

wwmason@cpp.edu

Instructor:

GAS

Nadim Itani

HW

100'

Wesley Mason

City of West Hollywood

HW

HW

1047 N Spaulding Ave West Hollywood, CA 90046

HW HW HW

HW

GAS GAS GAS

GAS

GAS

GAS

HW

GAS

West Hollywood Multi-Family Housing

Date

HW

HW

HW

HW

Description

GAS

HW

GAS

GAS

GAS

GAS

No.

GAS

HW

GAS

HW

5'

HW HW

GAS

HW

GAS GAS

TITLE

HW

GAS

HW

GAS

HW

Site Integration Job #

S-Zero Arc 472

Date

26 March, 2018

HW

Drawn by

24 x 36 Wesley Mason 00

HW

A-E1.2 .

HW HW

Scale

1/16” = 1’

6/26/2018 6:30 PM

HW

Revi sion #

HW

GAS

Size

GAS

25'

GAS

20'

GAS

130'

15'

GAS

20'

GAS

15'


GENERAL NOTE

SPECIFIC NOTE

Wesley Mason

wwmason@cpp.edu

Instructor:

Nadim Itani

West Hollywood Multi-Family Housing 1047 N Spaulding Ave West Hollywood, CA 90046 City of West Hollywood

No.

Top Roof +28’ 6”

Description

Date

HVAC System

Second Level +9’ 4” TITLE

Gas Line Water Line Sewer Line

Power Line Parking -13’ 0”

HVAC System

MEP Room

Utility Conceptual Layout Job #

S-Zero Arc 472

Date

26 March, 2018

Size Drawn by

24 x 36 Wesley Mason

Revi sion #

00

A-E1.3 Scale

1/16” = 1’

6/26/2018 6:30 PM

Grade +0’ 0” Finished Floor -4’ 0”


SLOPE

P.L.

GENERAL NOTE

CALCULATIONS DELTA T:

72F - 46.1 = 25.9

ROOF

R-VALUE

THROUGH JOIST (15%)

2x12 TRUS JOIST 1/2” GYPSUM BOARD

TOTAL R-VALUE

CANT STRIP WIDE FLANGE

0.17 0.62 0.33 0.06 15.2 0.61 16.99

THROUGH INSOLATION (85%)

CORRUGATED METAL CLADDING 2x4 FURRING STRIP WATERPROOFING MEMBRANE PLYWOOD SHEATHING

INSIDE AIR FILM 1/ 2” PLYWOOD 12” BATT INSOLATION BUILT UP ROOF WATERPROOF MEMBRANE OUTSIDE AIR FILM TOTAL R-VALUE

DOUBLE TOP PLATE DOUBLE PANE LOW E GLASS

0.17 0.62 30 0.33 0.06 0.61 31.79

TOTAL U-VALUE 1/ [(16.99 x 0.15) + (31.79 x 0.85)]= 0.0338

2x6 SILL PLATE ANCHOR BOLT WOOD DECKING

FLOOR

DRAIN

R-VALUE SPECIFIC NOTE

THROUGH STUD (15%)

INSIDE AIR FILM 1/2” PLYWOOD BUILT UP ROOF WATERPROOF MEMBRANE 2x12 WOOD JOIST OUTSIDE AIR FILM

COPING

WALL

R-VALUE

INSIDE AIR FILM 2x6 WOOD STUD DFL 1/2” GYP BOARD VAPOR BARRIER 5/8” PLYWOOD 2” AIR GAP 2x4 FURRING STRIP CORRUGATED METAL CLADDING OUTSIDE AIR FILM

0.68 6 0.45 0.06 0.77 2.41 2 0.61 0.17

TOTAL R-VALUE

13.15

THROUGH INSOLATION (85%) INSIDE AIR FILM 1/2” GYP BOARD VAPOR BARRIER 6” HIGH DENSITY BATT INSOLATION 5/8” PLYWOOD 2” AIR GAP 2x4 FURRING STRIP CORRUGATED METAL CLADDING OTSIDE AIR FILM

0.68 0.45 0.06 Wesley Mason

22.2 0.77 2.41 2

1.23 0.92 0.17

TOTAL R-VALUE

2.23

TOTAL U-VALUE 1/ [(13.15 x 0.15) + (29.35 x 0.85)]= 0.0371

TOTAL U-VALUE 1/ 2.23 =

0.43

WINDOW DOUBLE PANE LOW E

Nadim Itani

West Hollywood Multi-Family Housing 1047 N Spaulding Ave West Hollywood, CA 90046 City of West Hollywood

0.61 0.17

12” CONCRETE SLAB INSIDE AIR FILM OUTSIDE AIR FILM

TOTAL R-VALUE

wwmason@cpp.edu

Instructor:

29.35

No.

Description

Date

U-VALUE 0.33

CONCRETE RETAINING WALL

SAND GRAVEL

TITLE

U Values Job # Date

Drawn by

DRAIN PIPE 0’

2’ 1’

24 x 36 Wesley Mason

Revi sion #

01

M 2.1

8’ 4’

16 April, 2018

Size

Scale

1/2” = 1’

6/26/2018 6:30 PM

WATERPROOFING MEMBRANE


GENERAL NOTE

ARC 332 : E nvi ron mental Cont rols P rof. Hofu Wu , Arc h.D, FA IA

ARCH IT E CTUR E P OMONA C ali fo rnia S tate P oly tec hn ic Un ive rsi ty

Heating

Hea ting a nd Coo ling Lo ads C alc ula tion

Location:

P repa red by:

West Hollywood, CA

Hea ting Lo ad C alc ula tion -

I ndoo r Desi gn T emp. = 42 U- V al ue

R oof

722

x

0.0388

x

25.9

725.55

W alls

2063

x

0.0371

x

25.9

1982.32

G lass

412

x

0.33

x

25.9

3521.36

.

S lab on G rade

160 (LF) x

1.08 (F 2) x

25.9

4475.52

.

Governing 22,465.02 btuh x 1.2 = 26,958.024 btuh 26,958.024 btuh / 12,000 BTU/ ton = 2.25 = 2.5 Ton

25.9

6679.15

.

Infiltration

1.08

Del ta T

x

(

)

x

x

(

)

x

x

. . .

14,327 CFH / 60 min/ hour = 238.75 CFM = 250 CFM

T OTAL HE AT ING L OAD

17,383.90

Coo ling Lo ad C alc ula tion - I ndoo r Desi gn Cond ition = Item Tr ansmissi on: R oof ( ) R oof ( ) W all ( N ) W all ( S ) W all ( E ) W all ( W )

Area (S F)

S olar Tr ansmissi on: G lass (N ) G lass (W) G lass ( ) G lass ( )

Area (S F) 268 144

722 655 1041 260 106

x

U- V al ue x x x x x x

0.0388

x x x x x

DCLF 19 33

x

DE TD x x x x x x

0.0371 0.0371 0.0371 0.0371

728.35

3 6 13 13

72.90 231.73 125.40 51.12

. . . . .

5092 4752

. . . .

(watts) x 3.4 x (1.20 B allas t F actor) (watts) x 3.4 (no.) x 250 (s ensible heat )

6

(infil. fa ctor.) (vent.fa ctor.)

Tot al S ensi ble Hea t G ai n

. 1432.68

.

9477.84

Tot al L atent Hea t G ai n

200

(latent heat )

500

. .

400 400

Wesley Mason

wwmason@cpp.edu

Instructor:

Nadim Itani

West Hollywood Multi-Family Housing

Kitchen 81 SF / 1416 SF = 0.057 0.057 x 1200 CFM = 68.64 CFM 100 CFM 2.5” x 5”

Bedroom 1 123 SF / 1416 SF = 0.087 0.087 x 1200 CFM = 104.4 CFM 200 CFM 5” x 10”

Living/ Dining Room 360 SF / 1416 SF = 0.254 0.254 x 1200 CFM = 305 CFM 400 CFM 8” x 10”

Bedroom 2 125 SF / 1416 SF = 0.088 0.088 x 1200 CFM = 105.93 CFM 200 CFM 5” x 8”

Bathroom 1 60 SF / 1416 SF = 0.042 0.042 x 1200 CFM = 50.85 CFM 100 CFM 2.5” x 5”

Bathroom 1 60 SF / 1416 SF = 0.042 0.042 x 1200 CFM = 50.85 CFM 100 CFM 2.5” x 5”

Bathroom 2 52 SF / 1416 SF = 0.036 0.036 x 1200 CFM = 44.06 CFM 100 CFM 2.5” x 5”

Bathroom 2 52 SF / 1416 SF = 0.036 0.036 x 1200 CFM = 44.06 CFM 100 CFM 2.5” x 5”

1047 N Spaulding Ave West Hollywood, CA 90046 City of West Hollywood

No.

Description

Date

. .

22,464.02 (no.) x

Required CFM Total CFM = 1200 CFM Duct Size = Use 15” Round Duct Diameter

. .

.

Internal Heat G ain: L ight E quipment P eople

2

= BTUH

26

(S F) x (CFM) x

2323 5000 2

.

Outdoo r Desi gn Cond ition =

Outside Air: Inf iltration or Mech.V ent. 238.78

P eople

= BTUH

22,464.02 btuh / (1.08 x 20) = 1040 Use 1200 CFM Duct size: Use 15” Round Duct Diameter

Area (S F)

238.78 (CFM) x

x

Cooling

Outdoo r Desi gn T emp. = 46.1

Item

Infiltration

x

Wesley Mason

4/22/18

Date:

SPECIFIC NOTE

17,383.90 btuh / (1.08 x 50) = 321.92 Use 400 CFM Duct Size: Use 4” Round Duct Diameter

.

TITLE

Heating and Cooling Calculations Job #

.

Date

16 April, 2018

Size

S ensi ble Hea t R atio (S HR) = (T ot. S ensible Heat G ain) / (T ot. S en. Heat G ain + T ot. Latent Heat G ain) = 0.9825

Drawn by

24 x 36 Wesley Mason

Revi sion #

T OTAL C OO L ING L OAD (S ensi ble + L atent)

22,864.02

BTUH

01

M 2.2 Scale

6/26/2018 6:30 PM

West Hollywood Residential

P roject Title

System Size Calculation


GENERAL NOTE

SS-DZ20VC

DZ20VC

3

2

1

REV ZONE

ECN XXXXXXX

A

DESCRIPTION

CHK D

-

XXXXX

DATE

GL

E

Dimensions W”

D

D”

H”

DZ20VC0241**

35½

35½

38¼

DZ20VC0361**

35½

35½

41¼

DZ20VC0481**

35½

35½

41¼

DZ20VC0601**

35½

35½

41¼

SPECIFIC NOTE D

C

C

B

B

Daikin Manufacturing Co., LLC A

DRAWING TO BE INTERPRETED IN ACCORDANCE WITH ASME Y14.100 DIMENSIONS ARE IN INCHES UNLESS OTHERWISE NOTED

SPECIAL CHARACTERISTICS: 6s

COMPONENTS AND MATERIALS SPECIFIED HEREIN WILL ALSO CONFORM TO THE APPLICABLE SECTION OF GOODMAN MSP 824.01 WORKMANSHIP STANDARD FOR FIT, FEEL AND FINISH.

CC= CRITICAL CHARACTERISTIC

= 6SIGMA

8

7

SC= SIGNIFICANT CHARACTERISTIC

CONFIDENTIAL PROPERTY OF THE GOODMAN MANUFACTURING COMPANY, L.P. NOT TO BE DISCLOSED TO OTHERS, COPIED, OR USED FOR ANY PURPOSE EXCEPT AS AUTHORIZED IN WRITING. MUST BE RETURNED UPON DEMAND, ON COMPLETION OF ORDER, OR OTHER PURPOSE FOR WHICH IT WAS LENT.

6

4

5

TOLERANCES: ANGLES ± 1.5° .X : ± .1 .XX : ± .03

DWN BY:

2

3

A

DZ20VC ENG:

DO NOT SCALE DRAWING

SHT 1 OF 1

REV

.XXX : ± .015 HOLE Ø : ± .005 TUBE CUT LG: ± .063

A

1

ŝŵĞŶƐŝŽŶƐ

31

Nomenclature........................................ 2 ........................... 3 Expanded Cooling Data ......................... 4 ....................... 20 Performance Data Standard Mode ............................... 22 Boost Mode ..................................... 24 Sound Power Levels ............................ 25 .................. 26 ........................................ 27 Dimensions .......................................... 31 Wiring Diagrams .................................. 32 Accessories .......................................... 35

4

Model #

www.daikincomfort.com

Contents

5

6

E

HighͲ ĸĐŝĞŶĐy, ComfortNĞt™-CompaƟbůĞ, Split SysƚĞm HĞat Pump Up to 21 SEER

CooůŝŶŐ ĂpaĐŝƚy: 23,800 - 52,500 BTU/h HĞaƟŶŐ ĂpaĐŝƚy: 23,800 - 52,000 BTU/h

7

8

PrŽĚƵĐƚ ^ƉĞĐŝĮĐaƟŽŶƐ

Standard Features

Cabinet Features

• Daikin variable-speed swing and scroll compressors • High-density foam compressor sound blanket • • Daikin control algorithmic logic • voltage wires to outdoor unit required • LED display, and fault code storage • • Field-selectable boost mode increases compressor speed during unusually high loads • Quiet ECM outdoor fan motor • Fully charged for 15’ of tubing length • • Coil and ambient temperature sensors • • with easy access to gauge ports •

• • • • • • • •

DZ20VC 0241B*

Grille-style sound control top design

DZ20VC 0361B*

DZ20VC 0481B*

Wesley Mason

DZ20VC 0601B*

CapaciƟes and RaƟngs

500-hour salt-spray tested Wire fan discharge grille Steel louver coil guard Heavy-gauge galvanized-steel cabinet Top and side maintenance access Single-panel access to controls with space

Max Cooling (BTU/h)

wwmason@cpp.edu

Instructor:

Nadim Itani

West Hollywood Multi-Family Housing

23,800

35,400

46,500

52,500

23,800

35,000

46,000

52,000

Type

Swing

Swing

Swing

Scroll

RLA

12.70

27.30

27.30

28.60

1047 N Spaulding Ave West Hollywood, CA 90046

Compressor

City of West Hollywood

Condenser Fan Motor

• When properly anchored, meets the 2010 Florida Building Code unit integrity requirements for hurricane-type winds (Anchor bracket kits available.)

Horsepower

1/2

1/2

1/2

1/2

FLA

2.5

2.5

2.5

2.5

д"

д"

д"

д"

¾"

и"

ϭЯ"

ϭЯ"

д"

д"

д"

д"

¾"

и"

и"

и" Ball Valve

RefrigeraƟon System Refrigerant Line Size Liquid Line Size (“O.D.)

Liquid Valve Size (“O.D.)

Ball Valve

Ball Valve

Ball Valve

Refrigerant Charge

165

272

272

242

Superheat at Service Valve

7-9°F

7-9°F

7-9°F

7-9°F

Subcooling at Service Valve

7-9°F

7-9°F

7-9°F

7-9°F

208-230/1

208-230/1

208-230/1

208-230/1

15.2

29.8

29.8

31.1

20

30

30

35

Min / Max Volts

197/253

197/253

197/253

197/253

Electrical Conduit Size

No.

Description

Date

Electrical Data Volts-Phase (60 Hz) Minimum Circuit Ampacity ²

SS-DZ20VC

* Complete warranty details available from your local dealer or at www.daikincomfort.com. To receive the 12-Year Unit

www.daikincomfort.com

8/17 Supersedes 1/17

½" or ¾"

½" or ¾"

½" or ¾"

½" or ¾"

Equipment Weight (lbs)

220

285

285

345

Ship Weight (lbs)

240

305

305

365

ENERGY STAR® CerƟĮĞd Energy Star Notes •

TITLE

• be matched with appropriate coil components to meet ENERGY STAR criteria. Ask your contractor for details or visit www.energystar.gov.

HVAC Product Specifications

• ¹ Tested and rated in accordance with ANSI/AHRI Standard 210/240

Job # Notes • Always check the S&R plate for electrical data on the unit being installed. • • Unit is charged with refrigerant for 15’ of д͟ liquid line. System charge

Date

16 April, 2018

Size Drawn by

24 x 36 Wesley Mason

Revi sion #

01

M 2.3 SS-DZ20VC

www.daikincomfort.com

3 Scale

1/8” = 1’

6/26/2018 6:30 PM

matched with appropriate coil components to meet ENERGY STAR® criteria. Ask your contractor for details or visit www.energystar.gov.


GENERAL NOTE

SPECIFIC NOTE

6” Duct

6” Duct

200 CFM

3” Duct

Horizontal Supply Diffuser

300 CFM

100 CFM

Horizontal Supply Diffuser

Return Diffuser

Wesley Mason

Second Floor Plan 1/8” = 1’

wwmason@cpp.edu

Instructor:

Daikin DZ20VC0241B

Nadim Itani

West Hollywood Multi-Family Housing 1047 N Spaulding Ave West Hollywood, CA 90046 City of West Hollywood

Supply Duct 6” Duct

Return Duct

800 CFM No.

3” Duct 100 CFM

Description

Date

Thermostat

100 CFM

6” Duct 400 CFM

TITLE

HVAC Duct Layout

First Floor Plan 1/8” = 1’ Job #

16 April, 2018

Size Drawn by

24 x 36 Wesley Mason

Revi sion #

01

M 2.4 Scale

1/8” = 1’

6/26/2018 6:30 PM

Date


GENERAL NOTE

A

B

D

C

E

SPECIFIC NOTE

47' 8" 5'-10"

9'1"

7'-8"

25' 1"

11

14'-6"

The lighting fixtures are designed with three different layers of light for Ambient light, task light, and accent lighting

10

First layer- This layer consists of recessed downlights for the areas with lower ceilings, and pendant lighting that hangs down from the double height ceiling in the living room areas. The purpose of ambient lighting is to fill the entire room with light Second layer- This layer consists of more focused lights for specific tasks such as cooking in the kitchen and applying makeup or shaving in the bathroom

SECOND FLOOR PLAN

Third layer- This layer consists of accent lighting

A

B

D

C

E

Wesley Mason

wwmason@cpp.edu

Instructor:

Nadim Itani

West Hollywood Multi-Family Housing 1047 N Spaulding Ave West Hollywood, CA 90046 City of West Hollywood

47' 8" 9'-10"

11'-2"

18'-10"

7' 10"

14'-6"

11

RECESSED DOWN LIGHTING PENDANT LIGHTING TASK LIGHTING WALL WASHING ACCENT LIGHTING RECESSED LIGHTING STRIP

No.

Description

Date

10

TITLE

Lighting Design Concept

FIRST FLOOR PLAN

Job # Date

2’

8’

7 May, 2018

Size Drawn by

24 x 36 Wesley Mason

Revi sion #

1’

4’

01

16’

E-3.1 Scale

1/4” = 1’

6/26/2018 6:30 PM

0’


GENERAL NOTE

A

B

D

C

E

SPECIFIC NOTE

47' 8" 5'-10"

9'1"

7'-8"

25' 1"

11 S

LIGHTING SCHEDULE

14'-6"

SYMBOL

S

SSS

10

TOTAL WATTS

LUMEN

CRI

CCT

12

384

866

95+

3000K

72

8

11

88

1260

83

3000K

114

3

18

54

3991

83

3000K

221

RECESSED ACCENT EUREKA LINE 7480xx LIGHT

9

5/FT

252

800

83

3000K

29

WALL WASHING ACCENT LIGHT

LINEA 1.5” LINEAR DIRECT WALL WASH LED

4

5/FT

153

2557

83

3000K

512

EXTERIOR WALL MOUNTED LIGHT

EUREKA COUPÉ 4766-SIJD

2

13

26

1033

80

4000K

80

TYPE

LUMINARE MODEL

RECESSED DOWNLIGHT

ESSENZA DIM-TO-WARM ROUND DOWNLIGHT

32

PENDANT LIGHT

EUREKA SILENE CLASSIC 4156B-JDJ

TASK LIGHT

LINEA 1.5” MINI DIRECT/ INDIRECT

QUANTITY WATTS

EFFICACY

SECOND FLOOR PLAN

Wesley Mason

wwmason@cpp.edu

Instructor:

Nadim Itani

West Hollywood Multi-Family Housing 1047 N Spaulding Ave West Hollywood, CA 90046

A

B

D

C

E

City of West Hollywood

47' 8" 9'-10"

18'-10"

11'-2"

11

7' 10"

S

S

14'-6"

S

S3

SSS

SINGLE SWITCH 3- WAY SWITCH WEATHERPROOF GFI DUPLEX OUTLET 110V CONV ARC FAULT CIRCUIT INT DUP OUTLET EXAUST FAN

No.

Description

Date

PENDANT LIGHT

TASK LIGHT

S

S

S

RECESSED LIGHT

S S S

S S S3

10

WALL WASHING LIGHT RECESSED LIGHTING STRIP WALL MOUNTED OUTDOOR LIGHT

S S3

TITLE

Electrical Plans and Schedule

FIRST FLOOR PLAN

Job #

0’

Size

Date

8’

Drawn by

7 May, 2018 24 x 36 Wesley Mason

Revi sion #

1’

4’

01

16’

E-3.2 Scale

1/4” = 1’

6/26/2018 6:30 PM

2’


TYPE:

Essenza Round Downlight: 141/2” min - 26” max 111/2” 8 13/16”

Product Overview

TYPE:

Essenza Round Downlight: FIXTURE DATA: 15W LED, 3000K-95+ Flood (FL) Distribution, 35º LTL# 11919582.02 Lumens: 796

TYPE:

250

Ceiling cut out: 4” dia.

17/16”

4”

Trim

Trimless

Yes

Yes

750

2000

3000

Downlight

45

250

75

150

75

60

500

60

300

60

2 15/16”

15

0

30

Candelas at Nadir Deg Candela 0 3674 5 2877 15 1011 25 392 35 143 45 40

30°

3 8

15

45

45 600

0

30

Candelas at Nadir Deg Candela 0 1474 5 1392 15 900 25 434 35 192 45 72

15

0

30

Candelas at Nadir Deg Candela 0 1086 5 1051 15 799 25 459 35 223 45 92

15

30

Candelas at Nadir Deg Candela 0 648 5 629 15 497 25 317 35 189 45 118

/”

3 8

Ø2 3/4”

Application Data:

Ø4 3/8”

Lens Wall Wash

45

1000

up to 1”

/”

450

1500 0

2 15/16”

750

1250

Adjustable

Ø2 3/4”

Yes

SPECIFIC NOTE 90

75

1000

Ø4 3/8” Remodeler

GENERAL NOTE

500 60

up to 1”

Yes

Very Wide Flood (VWF) Distribution, 50º LTL # 11919582.04 Lumens: 663 90

1000

Fixture Type New Construction

Wide Flood (WF) Distribution, 45º LTL # 11919582.03 Lumens: 790 90

75

Recessed Round Downlight, Accent, Wall Wash 12W (IC/AT), 15W 866 lm max (EZRD trim, 15W, Spot optic) 3000K to 1800K 95+ TRIAC & ELV (120V/277V) - 5% Dim Lutron A Series (120V/277V), 3-wire/EcoSystem Hi-lume® - 1% dim Lutron H Series (120V/277V), EcoSystem, Hi-lume® 1% dim with soft on, fade to black 0-10V (120V/277V) - 1% Dim DALI dimming - 1% Dim

Adjustable

PROJECT:

Passion. Power. Performance.

PROJECT:

Very Narrow Flood (VNF) Distribution, 18º LTL # 11919582.01 Lumens: 866

3 1/8”

Downlight

Dim-To-Warm Round Downlights

90

3 1/8”

Type: Wattage: Lumen Output: Color Temp: CRI: Dimming:

Optional IC/AT housing (12w only)

2 1/4”

Essenza

®

DTW Essenza Round Downlights

PROJECT:

DTW Essenza Round Downlights

Passion. Power. Performance.

4”

Add ambiance to any hospitality, residential, retail or commercial space. Amerlux Essenza Downlight Dim-To-Warm option offers a lower kelvin temperature as you dim the lights. An adaptable light source in a cost- effective, solid state lighting package. The Dim-To-Warm option can tap into the powerful mediums of light and color to enhance the experience, well-being, and human emotion. Amerlux Dim-To-Warm allows designers to simulate the familiar glow and dimming of incandescent lamps.

Dim-To-Warm Round Downlights

6 1/8” 9” 123/16”

Features

Essenza

7 3/4”

Dim-To-Warm Round Downlights

Passion. Power. Performance.

DTW Essenza Round Downlights

Essenza ®

®

D

0 o Aiming Angle Horizontal Footcandles

Shower

CB 30°

30º

0.10

15

2 15/16”

2 15/16”

0.13

277V 12 0.04 16 Electronic constant current LED driver *Includes 2W thermal protector

0.06

Ø2 3/4”

/”

3 8

Pinhole Downlight

CCT (K)

2800

FC 57 26 15 9

L 3.1 4.5 5.9 7.5

W 3.1 4.5 5.9 7.5

D 5.0’ 7.5’ 10.0’ 12.5’

FC 42 19 11 7

L 3.6 5.4 7.2 9.0

W 3.6 5.4 7.2 9.0

D 5.0’ 7.5’ 10.0’ 12.5’

FC 25 11 7 4

L 3.8 5.7 7.7 9.7

W 3.8 5.7 7.7 9.7

FC

L

W W

FC

CB

L

W

FC

L

Notes and Definitions: Beam spread is to 50% center beam candlepower (CBCP). D=Distance to floor or wall. FC =Footcandles on floor or wall at center beam aiming location. L=Eff ective Visual Beam length in feet (50% of maximum footcandle level). W=Eff ective Visual Beam width in feet (50% of maximum footcandle level). CB =Distance across or down to center beam location.

2600 2400

2 15/16”

2200

3 1/8”

2000

Wesley Mason

Ø113/16” up to 1” 25

0

50

75

wwmason@cpp.edu

Instructor:

Ø4 3/8”

1800

3

D 5.0’ 7.5’ 10.0’ 12.5’

/”

3200

Pinhole Downlight

W 1.6 2.5 3.3 3.9

3 8

Ø2 3/4” Ø4 3/8”

Ø4 3/8”

3000

L 1.6 2.5 3.3 3.9

up to 1”

up to 1”

Dim-To-Warm CCT Curve Shower Sh

Very Narrow Flood

System Watts Amps

12

FC 141 64 36 23

Flood

System Watts Amps 120V

3 1/8”

15W*

3 1/8”

Wall Wash LLens W ll W h

12W (IC/AT)

D 5.0’ 7.5’ 10.0’ 12.5’

Wide Flood

Electrical Data

Very Wide Flood

D

Nadim Itani

100

Dimming (% of Light Output) LIT-2144• 03/15/18• Page 1 of 13 Amerlux reserves the right to change details that do not ectaff overall function and performance. • P: 973-882-5010 F: 973-882-2605 • amerlux.com Amerlux®, LLC• 178 Bauer Drive, Oakland, NJ 07436

LIT-2144• 03/15/18• Page 4 of 13 Amerlux reserves the right to change details that do not ectaff overall function and performance. • P: 973-882-5010 F: 973-882-2605 • amerlux.com Amerlux®, LLC• 178 Bauer Drive, Oakland, NJ 07436

LIT-2144• 03/15/18• Page 8 of 13 Amerlux reserves the right to change details that do not ectaff overall function and performance. • P: 973-882-5010 F: 973-882-2605 • amerlux.com Amerlux®, LLC• 178 Bauer Drive, Oakland, NJ 07436

West Hollywood Multi-Family Housing 1047 N Spaulding Ave West Hollywood, CA 90046 City of West Hollywood

VEGA 4233-XBL PROJECT PROJET

ORDERING SPECIFICATION

SPEC TYPE

SPÉCIFICATION DE COMMANDE

MODEL MODÈLE 4233-XBL

NOTES

CODE 4233-XBL

Anatomy

VEGA

Photometric Report

VEGA

VEGA XBL (ACRYLIC DIFFUSER) SOURCE LUMINEUSE

LIGHT SOURCE

LED.11

(WATTAGE, LAMP TYPE, OTHER INFO)

LED.11

11W, LED TEMPÉRATURE DE COULEUR

COLOR TEMPERATURE 30

3000K

35

3500K

40

4000K

VOLTAGE VOLTAGE 120V

120 VOLT

277V*

277 VOLT

TOUGH A large aluminium heatsink integrated inside the frame provides cooling to the LEDs.

*NOT AVAILABLE WITH A TRACK ADAPTOR

DIMMING OPTION

OPTION DE GRADATION

DV*

0-10V DIMMING (120V-277V)

DP

PHASE DIMMING (120V ONLY) LED DIMMING DRIVER IS STANDARD IN THIS PRODUCT, PLEASE SPECIFY YOUR DIMMING TYPE. *NOT AVAILABLE WITH A TRACK ADAPTOR

STEM OR CABLE

3/8" (10MM) STEM, NOT FIELD ADJUSTABLE

C

CLEAR CABLE, FIELD ADJUSTABLE

STEM OR CABLE LENGTH 36 60

FAMILY FAMILLE

** **

CCT (K): Delivered Lumens (lm): System wattage (W)*: Distribution:

RAW POWER A highly efficient 11.7W NICHIA COB at the center of every Vega-XBL ensure a strong lumen output.

TIGE OU CABLE

S10

4233-LED.11.40

CLASS ACT The chrome frame add a touch of prestige to the fixture and helps it to blend in its surroundings, picking up the colors of the environement.

LONGUEUR DE TIGE OU CABLE

Photometric type Luminous dimensions Luminous shape: Units: 0-180 Axis: 90-270 Axis: Height:

SIMPLE The driver is located inside the canopy; for easy maintenance.

36" STEM (STD LENGTH) 60" CABLE (STD LENGTH) CUSTOM STEM LENGTH (PLEASE SPECIFY)

PURE BEAUTY The finely sandblasted acrylic diffuser produces a fabulously charming glow.

CUSTOM CABLE LENGTH (PLEASE SPECIFY) FOR OVERALL LENGTH PLEASE CONTACT YOUR EUREKA REPRESENTATIVE.

Luminaire spacing criteria 2 luminaires, plane 0: 2 luminaires, plane 90: 4 luminaires:

ROUND CANOPY / PAVILLON ROND FOR LED: 0.50" CANOPY (2401C)*

4427-XBL

4425-XBL

TRACK ADAPTOR / ADAPTATEUR DE RAIL TA1

1 CIRCUIT

LED TRACK I CIRCUIT

LED

MOUNTING

2734F

2401C

CABLE

78.50”

77.30”

STEM

54.50”

53.30”

MOUNTING OPTIONS

SCA*

OPTION DE MONTAGE

WH

WHITE

BLK

BLACK

MG

METALLIC GRAY (A)

2734F 6.60” x 1.77” 168 x 45mm

2401C Ø4.50” x 0.50” Ø114 x 12.7mm

STEM OR CABLE OPTIONS STEM STD 36” 914mm

CHROME

SC

SATIN CHROME (B)

OPTIONS DE TIGE OU CABLE CABLE STD 60” 1523mm

ELEGANT Vega is a fixture made to illuminate spaces with a strong glow thanks to its diffusing tube.

18.50" 470mm

(A)

80 46

70

20.8”

60

92 107

50

122

(B)

I NCLUDE CANOPY FINISH IF A CANOPY IS SELECTED

DIFFUSER FINISH

FINI DIFFUSEUR

ACCESSORY

ACCESSOIRE

3983

DEEP JUNCTION BOX (PROVIDED WITH 2401C AS PER ABOVE)

PRODUCT CHARACTERISTICS

0 WH

WHITE

DESIGN: 4233-XBL

FINI STRUCTURE

CHR

WH

90

F ILL IN IF A TRACK ADAPTOR IS SELECTED, OTHERWISE LEAVE EMPTY

STRUCTURE FINISH

* OVERALL HEIGHT DOES NOT INCLUDE TRACK THICKNESS

Date

15

77

FINI ADAPTATEUR DE RAIL

Description

100 0

SLOPE CEILING ADAPTOR / ADAPTATEUR DE PLAFOND EN PENTE (ROTATION: 350°, PIVOT: 90°)

TRACK ADAPTOR FINISH

No.

31

*System wattage include driver and LED module consumption

*ONLY AVAILABLE WITH A STEM

OPTIONS DE MONTAGE

110

46

61

*3983 ACCESSORY IS PROVIDED

MOUNTING OPTION

LIGHT SOURCE

angles

120

31

6.54 6.54 6.01

LED 120V ADAPTOR (2734F)

HAUTEUR HORS TOUT

140

CARACTÉRISTIQUES DU PRODUIT

Slim and elegant design pendant may be mounted on track or canopy.

LIGHT SOURCE:

High performance LED Chip-on-board (COB) module with standard 0-10V or phase dimming

DIFFUSER:

Finely sandblasted acrylic with closed bottom.

CERTIFIED:

c-CSA-us

CONCEPTION:

Suspension élégante et élancée sur pavillon ou système de rails.

SOURCE LUMINEUSE:

Module DEL de type «

Chip-on-board » ( COB) à haute performance avec une unité

SPECIFICATION S

4233-XBL

LIGHT SOURCE DELIVERED LUMENS CRI LIGHT DISTRIBUTION DIFFUSER STRUCTURE MODULE VOLTAGE DRIVER DIMMING LM-79 WARRANTY

11W LED COB - System wattage : 13.9W 1260lm 83 CR I (Typicial) Diffused direct Closed top finely sandblasted acrylic (XBL) Machined & spin formed chromed steel UL R ecognized 120V (DP) or 120-277V (DV) CC 350mA, UL Recognized Phase dimming (DP) or 0-10V dimming (DV) By request 5 years

10

20

30

40

0 - 180 90 - 270

TITLE

Electrical Specs Job # Date

7 May, 2018

Size

24 x 36

d’alimentation à gradation 0-10V ou phase intégrée dans le luminaire. DIFFUSEUR:

Ø4.00" Ø102mm

CERTIFIÉ:

c-CSA-us

Drawn by

Wesley Mason

Revi sion #

01

E-3.3 Scale

6/26/2018 6:30 PM

OVERALL HEIGHT

170

cd

15

Rectangle in (mm) 3.600 (92) 3.600 (92) 18.000 (457)

4”

MOUNTING MONTAGE RC

3738-XBL

4000 1260 13.9 Direct 90.6 C


Passion. Power. Performance.

PROJECT:

TYPE:

Power Feed Suspension Kit

19/16" /8"

7

LEDs

Wattage: Lumen Output: Color Temp: CRI: Dimming:

For Asymmetric distribution this should be opposite the wall

1.17

Delivered Lumens

Color Temp

LPW

3991

95

6984

87.3

Overall length of run

J-Box (by others)

Solid Blade Louver

8'

38

0.32

74

0.62

277V

42.6

0.16

76

Note: Driver required for every 4'. Remote drivers can be installed up to 30' max from fixture.

REMOTE DRIVER BOX

AC Power feed by others

2 1/2"

80

0.66

160

1.32

80

0.30

160

0.60

163/4"

Low voltage plenum cable (5' supplied) J-Box (by others)

Ceiling

0.28

120V 277V

1.08

150

90

90

60 600

30

J-Box (by others)

ACROSS 45 ALONG

0

30

ZONAL LUMEN SUMMARY

ZONAL LUMEN SUMMARY

Zone 0-30 0-40 0-60 0-90 40-90 60-90 90-180 0-180

Zone 0-30 0-40 0-60 0-90 40-90 60-90 90-180 0-180

Lumens 620 966 1546 1857 891 312 2134 3991

%Fixt 15.53 24.21 38.72 46.54 22.31 7.82 53.46 100.00

Effective Floor Cavity Refl ectance 20% RC 80 RW 70 50 30 RCR 0 1.06 1.06 1.06 1 0.98 0.94 0.90 2 0.89 0.83 0.77 3 0.82 0.73 0.67 4 0.76 0.66 0.58 5 0.70 0.58 0.51 6 0.64 0.53 0.45 0.47 0.40 7 0.59 8 0.55 0.43 0.36 9 0.51 0.39 0.32 10 0.47 0.36 0.29

Lumens 448 639 853 930 291 77 2130 3060

%Fixt 14.64 20.90 27.88 30.40 9.50 2.51 69.60 100.00

Effi cacy = 72.8 Lumens /Watt

COEFFICIENTS OF UTILIZATION

Remote Driver

120V

1.0

300

0

2 1/4" Amps

0.93

120

Effi cacy = 95.0 Lumens /Watt

8' System Watts

0.87

60

Power Feed Canopy ASW10: 120" Aircraft Cable 10' White Cord 16/3 Ø5" White Canopy

4'

Electrical Data

Amps

2700K-83 3000K-83 3500K-83 4000K-83

Factor:

120

350

Non-Feed Canopy ASW10: 120" Aircraft Cable Ø5" White Canopy

3500K-83

System Watts

CCT: 1.75

180

150 ACROSS 45 ALONG

Perf Blade Louver

Blocking by G.C. (for direct fastening of Griplock)

Ceiling

Remote Driver

Wattage Per Foot

10W

SUSPENSION DETAIL AC Power feed by others

3500K-83

4'

9W

Total Watts: 42 Total Lumens: 3,060 Source: 184 White LED's LTL# 695284

LTL# 695283

Power Cord

Runs Individual Runs: 2' - 8' (whole foot standard) Continuous Runs: Available (whole foot standard) C ustom: Made to measure available (nearest 1/8" of field dimensions). Requires approval drawings. Added cost & lead time.

8W

1.34 1.50 1.64

700

Data is based on 3500K-83 IES fi les available on website Data is based on 4' fi xture with performance lens direct & batwing lens indirect

20

1.0

SPECIFIC NOTE

Performance Chart

10

0.63 0.82

/16"

Remote Driver (Supplied by Amerlux)

Fixture Summary (see following pages for more information)

10

MULTIPLYING FACTORS: Wattage: 3W 4W 5W 6W 7W

1

Low voltage plenum cable (5' supplied)

20

FIXTURE DATA:

180

11/2"

TYPE:

Wattage Per Foot

TYPE:

Total Watts: 42 Total Lumens: 3,991 Source: 184 White LED's

Optional Asymmetric Lens

*International version available, see website for spec sheet.

PROJECT:

Passion. Power. Performance.

PROJECT:

Factor:

2 1/8"

Direct/Indirect, Remote Driver Lens, Louver Down/Batwing, Clear lens up 5W/ft, 10W/ft (other wattages available see p2) 3,991 Lm; 95.0 Lm/W (10W, 4ft fi xture) 2700K, 3000K, 3500K, 4000K 83 typ. (2700K, 3000K, 3500K, 4000K) 0-10V, 1% dimming (standard) Lutron Hi- lume® 3 wire, 1% dim Lutron Hi- lume® Ec oS ystem, 1% dim Lutron Hi- lume® 2 wire (120 V only) Lutron Hi- lume® Ec oS ystem, 1% dim, fade to off Lutron Hi- lume® 5 S eries DAL I dimming, 0 .1% dim

Linear Mini Direct/Indirect, Remote Driver

Power Feed

Product Overview Type:

Linea® 1.5” Mini Direct Indirect

Linea 1.5" Mini Direct/Indirect

Linea drives your design scenario, seamle ssly. Streamlined and flexible, these architectural LED pendants provide the freedom to create truly dynamic spaces. A synthesis of aesthetics, performance and energy efficiency, the Linea family delivers on its promises. Our tiny new Linea 1.5'' pendant proves when it comes to lighting, less really is more. Linea. The power of disciplined design.

Linear Mini Direct/Indirect, Remote Driver

Linea 1.5" Mini Direct/Indirect

Features

Linea® 1.5” Mini Direct Indirect

Wall

Linear, Remote Driver

Passion. Power. Performance.

Linea 1.5" Mini Direct/Indirect

Linea® 1.5” Mini Direct/Indirect

GENERAL NOTE

COEFFICIENTS OF UTILIZATION 10 1.06 0.87 0.72 0.61 0.53 0.45 0.40 0.35 0.30 0.27 0.24

Effective Floor Cavity Refl ectance 20% RC 80 RW 70 50 30 RCR 0 1.02 1.02 1.02 1 0.94 0.91 0.87 2 0.87 0.80 0.75 3 0.80 0.72 0.66 4 0.74 0.65 0.58 5 0.68 0.57 0.51 6 0.63 0.53 0.45 7 0.59 0.48 0.40 8 0.55 0.43 0.36 9 0.51 0.40 0.33 10 0.47 0.36 0.30

10 1.02 0.84 0.70 0.60 0.52 0.46 0.40 0.36 0.32 0.28 0.25

Power Cord

Power Cord

Electronic multi-volt (120V-277V), constant current LED driver

Yes

Yes

Yes

Wesley Mason " " Yes

"" Yes

" Wall to Ceiling No

Custom* Yes

Nadim Itani

8'

* Submit drawing, consult factory LIT-2127• 03/20/18• Page 1 of 9 Amerlux reserves the right to change details that do not ectaff overall function and performance. • P: 973-882-5010 F: 973-882-2605 • amerlux.com Amerlux®, LLC• 178 Bauer Drive, Oakland, NJ 07436

wwmason@cpp.edu

Instructor:

4'

LIT-2127• 03/20/18• Page 4 of 9 Amerlux reserves the right to change details that do not ectaff overall function and performance. • P: 973-882-5010 F: 973-882-2605 • amerlux.com Amerlux®, LLC• 178 Bauer Drive, Oakland, NJ 07436

LIT-2127• 03/20/18• Page 7 of 9 Amerlux reserves the right to change details that do not ectaff overall function and performance. • P: 973-882-5010 F: 973-882-2605 • amerlux.com Amerlux®, LLC• 178 Bauer Drive, Oakland, NJ 07436

West Hollywood Multi-Family Housing 1047 N Spaulding Ave West Hollywood, CA 90046 City of West Hollywood

No.

Description

Date

TITLE

Electrical Specs Job # Date

7 May, 2018

Size Drawn by

24 x 36 Wesley Mason

Revi sion #

01

E-3.4 Scale

6/26/2018 6:30 PM

Standard Patterns " " " " "

5


Features

Linea® 1.5” Direct Wall Wash Linear Direct Wall Wash LED Passion. Power. Performance.

PROJECT:

TYPE:

LINEA 1.5" WALL WASH 15/8"

This amazing new light takes the shape of Linea 1.5" with a whole new purpose. A new star in the wall washing lighting category, this pendant has captured the imaginations of lighting designers worldwide. Linea 1.5" and the new.5" Linea 1 Wall Wash make the perfect pair for every office space.

/8"

7

Linea® 1.5” Direct Wall Wash

Linea 1.5" Wall Wash

Linear Direct Wall Wash LED

Passion. Power. Performance.

Linea 1.5" Wall Wash

Linea® 1.5”

Linear Direct Wall Wash LED Passion. Power. Performance.

PROJECT: FIXTURE DATA:

Power Feed Suspension Kit

MULTIPLYING FACTORS: Wattage:

Feed location

3 1/4"

Cable Suspended or Surface Direct 5W/ft, 10W/ft (other wattages available see p2) 2,557 max; up to 73.4 Lm/W 2700K, 3000K, 3500K, 4000K 83 typ. (2700K, 3000K, 3500K, 4000K) 0-10V, 1% dimming (standard) Lutron Hi- lume® 3 wire, 1% dim Lutron Hi- lume® Ec oS ystem, 1% dim Lutron Hi- lume® 2 wire (120 V only) Lutron Hi- lume® Ec oS ystem, 1% dim, fade to off Lutron Hi- lume® 5 S eries DAL I dimming, 0 .1% dim

3W

Factor:

Product Overview Type: Wattage: Lumen Output: Color Temp: CRI: Dimming:

TYPE:

Linea 1.5" Wall Wash

GENERAL NOTE

4W

5W 6W 7W

0.63 0.82

1.0

1.17

8W

9W

CCT:

1.34 1.50 1.64

2700K-83 3000K-83 3500K-83 4000K-83

Factor:

0.87

0.93

1.0

LINEA 1.5” DIRECT WALL WASH 5W 3500K 4FT

LINEA 1.5” DIRECT WALL WASH 10W 3500K 4FT

Total Watts: 19 Total Lumens: 1,384 Source: 96 White LED's

Total Watts: 38 Total Lumens: 2,557 Source: 96 White LED's

120

135

150 165

165 150

135

120

105

105

90

90

75

120

135

150 165

165 150

135

120

105

90

90

75

250

150

75

60

/8"

SPECIFIC NOTE

LTL# 11665872.04

LTL# 11665872.03 105

1.08

75 60

7

500

300

/32" Overall length of run

3

11/2"

Hairline seam

60

45

60

45

750

450

LINEA 1.5" WALL WASH SURFACE MOUNT

1000

600

6" from end of fixture (2 per fixture)* Feed location 2 1/4"

Mounting Screws (by others)

PROJECT:

3 1/4" /8"

7

System Watts

5 10

/32" Overall length of run

3

4' Wattage Per Foot

11/2"

8' Amps

System Watts

Hairline seam

Amps

120V

19

0.16

277V

21.3

0.08

38

37

120V

40

0.33

80

0.66

277V

40

0.15

80

0.30

0

15

270 Deg. Plane

15

30

0 Deg. Plane

0

180 Deg. Plane

90 Deg. Plane

15

270 Deg. Plane

30

0 Deg. Plane

90 Deg. Plane

Mounting location

Fixture Summary (see following pages for more information)

Electrical Data

30

15

180 Deg. Plane

TYPE:

Runs Individual Runs: 2' - 8' (whole foot standard) Continuous Runs: Available (whole foot standard) C ustom: Made to measure available (nearest 1/8" of field dimensions). Requires approval drawings. Added cost & lead time.

45

45

30

* = 5" from end of fixture for 2' housing

0.31 0.14

ZONAL LUMEN SUMMARY

ZONAL LUMEN SUMMARY

Zone 0-40 0-60 0-90 90-180

Zone 0-40 0-60 0-90 90-180

Lumens 589 955 1331 53

%Fixt 42.5 69.0 96.2 3.9

Lumens 1085 1760 2458 99

%Fixt 42.4 68.8 96.1 3.9

Effi cacy = 73.4 Lumens /Watt

Effi cacy = 66.6 Lumens /Watt

COEFFICIENTS OF UTILIZATION

COEFFICIENTS OF UTILIZATION

Effective Floor Cavity Refl ectance 20% RC 80 RW 70 50 30 RCR 0 1591 1591 1591 1 1423 1354 1291 2 1287 1174 1079 3 1172 1031 921 4 1075 917 800 5 992 824 705 6 920 747 629 7 857 682 567 8 801 626 514 9 752 579 471 10 708 537 433

Effective Floor Cavity Refl ectance 20% RC 80 RW 70 50 30 RCR 0 2939 2939 2939 1 2627 2498 2382 2 2375 2166 1991 3 2163 1903 1699 4 1984 1693 1476 5 1831 1521 1301 6 1697 1378 1160 7 1581 1258 1045 8 1478 1156 949 9 1387 1067 868 10 1306 991 799

10 1591 1234 999 832 710 616 543 485 437 397 363

Note: Values expressed as Lumens Delivered to the task surface.

10 2939 2277 1842 1535 1308 1136 1002 893 805 731 669

Note: Values expressed as Lumens Delivered to the task surface.

Electronic multi-volt (120V-277V), constant current LED driver

Wesley Mason

LIT-2048 • 03/20/18• Page 1 of 8 Amerlux reserves the right to change details that do not ectaff overall function and performance. Amerlux®, LLC• 178 Bauer Drive, Oakland, NJ 07436 • P: 973-882-5010 F: 973-882-2605 • amerlux.com

ORDERING SPECIFICATION

SPEC TYPE

CODE

SPÉCIFICATION DE COMMANDE

MODEL MODÈLE 4766-SIJ

NOTES

ANATOMY

4766-SIJ

COUPÉ Ø 5.90" Ø 150mm

COUPÉ

(WATTAGE, LAMP TYPE, OTHER INFO)

LED.13

26W, LED

COLOR TEMPERATURE 30

3000K

35

3500K

40

4000K

MOUNTING OPTIONS Rigid stem / aircraft cable, or surface

Ø 9.37" Ø 238mm

TEMPÉRATURE DE COULEUR

120V

120 VOLT

277V

277 VOLT

DIMMING OPTION DP

3.66' ' 93mm

PHASE DIMMING (120V ONLY)

FINI RADIATEUR

FINI DIFFUSEUR INTÉRIEUR

CDP

HIGH OUTPUT FOR GENERAL ILLUMINATION Center moun ted COB LED technology As much as 2400 lumens for on ly 26 W

3.66' ' 93mm

FLAT OPTICS Compound lens structured around layers of diffusing and deglaring CDP PMMA.

Ø 4.13" Ø 105mm Add a conical metal shade for a modern look and you have the Turbo.

Variable length depending on stem options.

INSTALLATION: to an integrated connection box. Also designed for outdoor projects, Coupé & Turbo 13W or 26W LED Chip-on-board (COB) emitter. Electronic dimming available on all models.

STRUCTURE:

Durable die cast aluminum enclosure with stainless steel spring clips. Turbo has an

DIFFUSER:

Compound lens structured around layers of diffusing and conical deglaring prismatic

3.66' ' 93mm

sheet PMMA. CERTIFIED:

CSA Listed to US and Canadian safety standards; 25°C ambient and wet-locations.

CONCEPTION:

Coupé est un luminaire au look industriel, assez mince pour être installé sur des plafonds

Ø 9.37" Ø 238mm

Description

Date

FERMOIRS EN ACIER RESSORT Accès facile à la source lumineuse, au besoin INTENSITÉ POUR ÉCLAIRAGE GÉNÉRAL Densité de sources (”Chip-on-Board” COB) Jusqu’à 2400 lm pour aussi peu que 26 W

3.66' ' 93mm

4266 SUSPENSION SUR CÂBLES

LENTILLE COMPOSÉE Superposition de couches de PMMA qui diffusent et réduisent l'éblouissement (CDP).

Ø 4.13" Ø 105mm Variable length depending on stem options.

RÉSISTE AUX INTEMPÉRIES Joints d’étanchéité autocollants Silicone éponge découpé à l’emporte-pièce Compression mécanique Scellage complet Convient aux endroits mouillés (CSA aux standards UL)

3.66' ' 93mm

Ø 9.37" Ø 238mm

4266B SUSPENSION STEM

IP64 rated

Ø 9.37" Ø 238mm

WEATHERPROOF Self-adhesive gaskets Die-cut silicone sponge Mechanically compressed Fully sealed Wet location rated (CSA to UL standards)

can be used in wet locations. LIGHT SOURCE:

MAX 64.66' ' 1642mm

STAINLESS STEEL SPRING CLIPS Easy access inside light chamber, if need be

4266 SUSPENSION CABLE

CARACTÉRISTIQUES DU PRODUIT

DESIGN:

4266B SUSPENSION SUR TIGE

bas. Ajoutez-y un abat-jour métallique conique pour obtenir un look moderne avec le Turbo. INSTALLATION:

Ces plafonniers sont parfaits pour des applications intérieures et faciles à installer grâce à leur boîte de connexion intégrée. Conçus aussi pour les projets extérieurs, Coupé et Turbo

CHARACTERISTICS

4766 / 4266 / 4266b

CARACTÉRISTIQUES

4766 / 4266 / 4266b

LIGHT SOURCE MODULE DELIVERED LUMENS CRI ROHS HOUSING HEAT SINK LIGHT DISTRIBUTION OPTICS GASKETS VOLTAGE DRIVER (DIMMING) LM-79 WARRANTY

1 x COB - total ±26 w 1 x COB - total ±13 w UL Recognized 1033 lm (4000K ) 574 lm (4000K ) 80 CRI (typical ) Yes Die-cast aluminum, black anodised (2,5mm thickness ) Die-cast aluminum, black anodised (variable thickness ) Direct Diffusing flat PMMA lens, Deglaring CDP PMMA lens (minimum 3 mm thickness for each layer) Die-cut self-adhesive silicone gasket (minimum 3,2mm thickness) 120V (Phase dimming) or 120-277 V (0-10V dimming) Phase dimming (DP) or 0-10V dimming (DV) Available On request 5 years

SOURCE LUMINEUSE MODULE LUMENS RÉELS IRC ROHS BOÎTIER RADIATEUR DISTRIBUTION LUMINEUSE OPTIQUES JOINTS D’ÉTANCHÉITÉ VOLTAGE PILOTES (AVEC GRADATION) LM-79 GAR ANTIE

1 x COB - total ±26 w 1 x COB - total ±13 w Reconnu par UL 574 lm (4000K ) 1033 lm (4000K ) 80 IRC (typique ) Conform e Aluminium moulé sous pression, anodisé noir (épaisseur 2,5mm ) Aluminium moulé sous pression, anodisé noi r (épaisseurs variables) Direct Lentille composée de couches de PMMA qui diffusent et réduisent l'éblouissement. (CDP, épaisseur minimum 3 mm) Silicone éponge autocollant, découpé à l’emporte-pièce (épaisseur minimum 3,2mm) 120V (Gradation phase) ou 120-277 V (Gradation 0-10V) Gradation phase (DP) ou Gradation 0-10V (DV) Disponible Sur demande 5 ans

peuvent être utilisés dans des endroits mouillés. SOURCE LUMINEUSE:

Émetteur DEL de format «

Chip-on-board » (COB) de 13W ou 26W. Gradation offert sur

tous modèles. STRUCTURE:

Boîtier durable en aluminium moulé avec fermoirs en acier ressort. Turbo est muni

DIFFUSEUR:

Lentille composée de couches de PMMA munis de prismes anti-éblouissement.

CERTIFIÉ:

Homologué CSA aux standards UL Canada et É.-U. - Température ambiante 25°C et emplacements mouillés. Conforme à la norme IP64

225 de Liège Oue st, Suite #200 Montréal (QC), Canada H2P 1H4 Tel : 514.385.3515 Fax : 514.385.4169 www.eu rekalighting. com

SPECIFICATION Eureka Lighting © 2017

No.

Ø 4.57" Ø 116mm

CONICAL DEGLARING PRISM

PRODUCT CHARACTERISTICS

J-BOX 4.69" 119mm

CONÇU POUR LE DÉSASSEMBLAGE Installation et entretien facile Matériaux recyclables Pièces jointes mécaniquement

4766 PLAFONNIER

Ø 9.37" Ø 238mm

Ø9.37" Ø238mm

GARDER LA TÊTE FROIDE Aluminium moulé s ous pressi on Anodisé noir pour une gestio n thermique améliorée

3.66' ' 93mm

Ø 4.57" Ø 116mm

MAX 64.66' ' 1642mm

3.66" 93mm

OPTIONS DE MONTAGE Câble d’acier, tig e fixe, ou en surface .

BLKA

BLACK ANODISED

INTERIOR DIFFUSER FINISH

4766-SIJ

CHIC INDUSTRIEL Compatible dans un éventail de décors (plafond bas, escalier , garage, extérieur,...)

Ø 9.37" Ø 238mm

.

4766 SURFACE

LED DIMMING DRIVER IS STANDARD IN THESE PRODUCTS, PLEASE SPECIFY YOUR DIMMING TYPE.

CDP

Ø 5.90" Ø 150mm

DESIGNED FOR DISASSEMBLY Easy in stallation and main tenance Rec yclab le ma terials Mechani cal ly fastened parts

OPTION DE GRADATION

0-10V DIMMING (120-277V)

HEATSINK FINISH BLKA

4266-SIJ

1047 N Spaulding Ave West Hollywood, CA 90046

COUPÉ

KEEPING THINGS COOL Precise ly calcula ted, air exposed heat sink, sturdy die cast aluminum, black anodised finish.

VOLTAGE VOLTAGE

FAMILY FAMILLE

Nadim Itani

West Hollywood Multi-Family Housing

13W, LED

LED.26

DV

ANATOMIE

INDUSTRIAL CHIC Works in a wide range of envi ronments (bars, ho tels, lofts, indoor, outdoor,...)

SOURCE LUMINEUSE

LIGHT SOURCE

4766-SIJ

LIT-2048 • 03/20/18• Page 6 of 8 Amerlux reserves the right to change details that do not ectaff overall function and performance. Amerlux®, LLC• 178 Bauer Drive, Oakland, NJ 07436 • P: 973-882-5010 F: 973-882-2605 • amerlux.com

www.eurekalighting.com

V1.0-2017-06

Eu reka Lig hting©201 7

www.eurek alighting.co m

4766-SIJ 4266-SIJ / 4266B-SIJ

225 de Liège Oue st, Suite #200 Montréal (QC), Canada H2P 1H4 Tel : 514.385.3515 Fax : 514.385.4169 www.eu rekalighting. com V3.0-20170 5

Eu reka Lig hting©201 7

www.eurek alighting.co m

TITLE

Electrical Specs Job # Date

7 May, 2018

Size Drawn by

24 x 36 Wesley Mason

Revi sion #

4766-SIJ 4266-SIJ / 4266B-SIJ

01

E-3.5

V3.0-20170 5

Scale

6/26/2018 6:30 PM

PROJECT PROJET

LIT-2048 • 03/20/18• Page 4 of 8 Amerlux reserves the right to change details that do not ectaff overall function and performance. Amerlux®, LLC• 178 Bauer Drive, Oakland, NJ 07436 • P: 973-882-5010 F: 973-882-2605 • amerlux.com

City of West Hollywood

COUPÉ 4766-SIJ

4766-SIJ

wwmason@cpp.edu

Instructor:

5


Turn static files into dynamic content formats.

Create a flipbook
Construction Documents by Wesley Mason - Issuu