Skip to main content

ERP WWP LS 8 kW Væghængt varmepumpe

Page 1

Max Weishaupt A/S Erhvervsvej 10 2600 Glostrup

Weishaupt WWP LS 8-B R-E

A ++

A++

Page 1of 4

Max Weishaupt A/S_20200930_103210.pdf


1

Årsvirkningsgrad ved rumopvarmning for varmepumpe Temperaturstyring

134 % 2

Klasse I = 1 %, Klasse II = 2 %, Klasse III = 1,5 %, Klasse IV = 2 %, Klasse V = 3 %, Klasse VI = 4 %, Klasse VII = 3,5 %, Klasse VIII = 5 %

Fra temperaturstyringens datablad

Supplerende kedel

2 %

+

Årsvirkningsgrad ved rumopvarmning (i %) 3

(

Fra kedlens datablad

– 134 ) x 0

0

Solvarmebidrag Fra solvarmekomponentens datablad

Solfangerens effektivitet (i %)

Beholderens vandindhold (i m³)

Solfangerens størrelse (i m²)

=

±

0 %

Beholderens Klassificering A⁺ = 0,95, A = 0,91, B = 0,86, C = 0,83, D-G = 0,81 4

(0 x

0

+0x

0

) x 0,45 x (

0

/ 100 ) x

=

0

0 %

+

5

Pakkens årsvirkningsgrad ved rumopvarmning under gennemsnitlige klimaforhold

136 %

Pakkens klasse for årsvirkningsgrad ved rumopvarmning under gennemsnitlige klimaforhold

Pakkens klasse for årsvirkningsgrad ved rumopvarmning under koldere og varmere klimaforhold 5

Koldere:

136

5

- 27 =

109

%

Varmere:

136

+ 10 =

146

%

Den her anførte virkningsgrad for denne produktpakke svarer ikke nødvendigvis til den faktiske virkningsgrad efter installation i en bygning. Den afhænger nemlig af andre faktorer som f.eks. varmetab i distributionssystemet og produkternes dimensionering i forhold til bygningens størrelse og egenskaber.

Page 2of 4

Max Weishaupt A/S_20200930_103210.pdf


WWP LS 8-B R-E

A++

0

6 6 7

A+++

6 7 8

60 Page 3of 4

Max Weishaupt A/S_20200930_103


EU Overensstemmelseserklæring Producent:

Max Weishaupt GmbH Max-Weishaupt-Straße D-88475 Schwendi

Produkt:

Varmeproducent

WWP LS 8-B R-E

Det ovennævnte produkt er i overensstemmelse med bestemmelserne i følgende direktiver: EDD 2009 / 125 / EC Test regler:

813/2013/EU, EN 12102:2013, EN 14511:2013, EN 14825:2016

ELR (EU) 2017 / 1369 Test regler:

811/2013/EU

Dette produkt tildeles følgende mærkning:

Schwendi, 14.12.2018 ppa.

ppa.

Dr. Schloen Leder forskning

Buschle Leder produktion og kvalitet

Produktdata Temperaturanvendelse

Varmeproducent Klassifikation for den årstidsbetingede rumvarmeenergieffektivitet (A+++ - D) Max. Varmeydelse ved gennemsnitlige klimaforhold Årstidsbetinget rumopvarmnings-energieffektivitet ved gennemsnitlige klimaforhold Årligt energiforbrug som samletenergi for rumopvarmning ved gennemsnitlige klimaforhold Lydeffektniveau, LWA Spicielle forhold ved installationen Max. Varmeydelse ved køligere klimaforhold Max. Varmeydelse ved varmere klimaforhold Årstidsbetingede rumopvarmnings-energieffektivitet ved køligere klimaforhold Årstidsbetingede rumopvarmnings-energieffektivitet ved varmere klimaforhold Årligt energiforbrug for rumopvarmning som slutenergi ved køligere klimaforhold Årligt energiforbrug for rumopvarmning som slutenergi ved varmere klimaforhold Lydeffektniveau LWA i det fri, LWA Reguleringens modelgenkendelse Termostatens klassifikation Reguleringens bidrag fra den årstidsbetingede energieffektivitet Årstidsbetinget rumopvaramnings-energieffektivitet for varmeanlægget Klassifikation for den årstidsbetingede rumopvarmnings-energieffektivitet for varmeanlægget (A+++ - G)

Page 4of 4

35°C

WWP LS 8-B R-E

A+++ 7 185 3266

55°C A++ 6 134 3766

dB(A)

0 see manual 6 8 137 238 4479 1711

6 7 107 144 5321 2726 60

kW % kWh

kW kW % % kWh kWh dB(A)

WWP-SG II 2 % 136 % A++

Max Weishaupt A/S_20200930_103210.pdf


Technical parameters

- weishaupt -

Manufacturer:

Max Weishaupt GmbH

Model:

WWP LS 8-B R-E Air-to-water heat pump

Low-temperature heat pump:

Nein

Equipped with a supplementary heater:

Ja

Heat pump combination heater:

Nein

Application:

low

Climate:

average

Item

Symbol

Rated heat output (*)

Prated

Value 7

Unit

Item

kW

Seasonal space heating energy efficiency

Declared capacity for heating for part load at indoor temperature 20°C and outdoor temperature Tj

Symbol

Value

Unit

ηs

185

%

Item

Symbol

Degradation co-efficient (**)

Cdh

Value

Declared coefficient of performance or primary energy ratio for part load at indoor temperature 20°C and outdoor temperature Tj

Tj = -7°C

Pdh

6,3

kW

Tj = -7°C

COPd

2,89

Tj = -7°C

Cdh

1,00

Tj = +2°C

Pdh

3,7

kW

Tj = +2°C

COPd

4,41

Tj = +2°C

Cdh

1,00

Tj = +7°C

Pdh

2,8

kW

Tj = +7°C

COPd

6,92

Tj = +7°C

Cdh

1,00

Tj = +12°C

Pdh

3,3

kW

Tj = +12°C

COPd

9,70

Tj = +12°C

Cdh

0,90

Tj = bivalent temperature

Pdh

5,7

kW

Tj = bivalent temperature

COPd

3,24

Tj = operation limit temperature

Pdh

6,0

kW

Tj = operation limit temperature

COPd

2,56

For air-to-water heat pumps: Tj = -15°C (if TOL <-20°C)

Pdh

kW

For air-to-water heat pumps: Tj = -15°C (if TOL <-20°C)

COPd

For air-to-water heat pumps: Tj = -15°C (if TOL <-20°C)

Cdh

Bivalent temperature

Tbiv

°C

For air-to-water heat pumps: Operation limit temperature

TOL

-10

°C

WTOL

55

°C

-5

Heating water operating limit temperature Power consumption in modes other than active mode Off mode

POFF

0,006

kW

Thermostat-off mode

PTO

0,073

kW

Standby mode

PSB

0,008

kW

Crankcase heater mode

PCK

0,000

kW

Supplementary heater Rated heat output (*)

Psup

Type of energy input

kW

Electricity

Other items Capacity control

variable

Sound power level, indoors/outdoors

LWA

Annual energy consumption

QHE

0 / 60

3.266

dB

For air-to-water heat pumps: Rated air flow rate, outdoors

--

For water-/brine-to water heat pumps: Rated brine or water flow rate, outdoor heat exchanger

--

m3/h

Water heating energy efficiency

ηwh

%

Annual electricity consumption

AEC

kWh

2.700

m3/h

kWh

For heat combination heater: Declared load profile Daily electricity consumption Contact details

Qelec

kWh

Max Weishaupt GmbH, Max-Weishaupt-Straße 14, 88475 Schwendi, Tel. 07353/83-0

(*)

For heat pump space heaters and heat pump combination heaters, the rated heat output Prated is equal to the design load for heating Pdesignh, and the rated heat output of a supplementary heater Psup is equal to the supplementary capacity for heating sup(Tj).

(**)

If Cdh is not determined by measurement then the default degradation coefficient is Cdh = 0,9.


Technical parameters

- weishaupt -

Manufacturer:

Max Weishaupt GmbH

Model:

WWP LS 8-B R-E Air-to-water heat pump

Low-temperature heat pump:

Nein

Equipped with a supplementary heater:

Ja

Heat pump combination heater:

Nein

Application:

medium

Climate:

average

Item

Symbol

Rated heat output (*)

Prated

Value 6

Unit

Item

kW

Seasonal space heating energy efficiency

Declared capacity for heating for part load at indoor temperature 20°C and outdoor temperature Tj

Symbol

Value

Unit

ηs

134

%

Item

Symbol

Degradation co-efficient (**)

Cdh

Value

Declared coefficient of performance or primary energy ratio for part load at indoor temperature 20°C and outdoor temperature Tj

Tj = -7°C

Pdh

5,6

kW

Tj = -7°C

COPd

2,15

Tj = -7°C

Cdh

0,99

Tj = +2°C

Pdh

3,4

kW

Tj = +2°C

COPd

3,31

Tj = +2°C

Cdh

1,00

Tj = +7°C

Pdh

2,5

kW

Tj = +7°C

COPd

4,56

Tj = +7°C

Cdh

0,96

Tj = +12°C

Pdh

3,1

kW

Tj = +12°C

COPd

6,82

Tj = +12°C

Cdh

0,95

Tj = bivalent temperature

Pdh

4,5

kW

Tj = bivalent temperature

COPd

2,42

Tj = operation limit temperature

Pdh

5,9

kW

Tj = operation limit temperature

COPd

1,83

For air-to-water heat pumps: Tj = -15°C (if TOL <-20°C)

Pdh

kW

For air-to-water heat pumps: Tj = -15°C (if TOL <-20°C)

COPd

For air-to-water heat pumps: Tj = -15°C (if TOL <-20°C)

Cdh

Bivalent temperature

Tbiv

°C

For air-to-water heat pumps: Operation limit temperature

TOL

-10

°C

WTOL

55

°C

-4

Heating water operating limit temperature Power consumption in modes other than active mode Off mode

POFF

0,006

kW

Thermostat-off mode

PTO

0,000

kW

Standby mode

PSB

0,008

kW

Crankcase heater mode

PCK

0,000

kW

Supplementary heater Rated heat output (*)

Psup

Type of energy input

kW

Electricity

Other items Capacity control

variable

Sound power level, indoors/outdoors

LWA

Annual energy consumption

QHE

0 / 60

3.766

dB

For air-to-water heat pumps: Rated air flow rate, outdoors

--

For water-/brine-to water heat pumps: Rated brine or water flow rate, outdoor heat exchanger

--

m3/h

Water heating energy efficiency

ηwh

%

Annual electricity consumption

AEC

kWh

2.700

m3/h

kWh

For heat combination heater: Declared load profile Daily electricity consumption Contact details

Qelec

kWh

Max Weishaupt GmbH, Max-Weishaupt-Straße 14, 88475 Schwendi, Tel. 07353/83-0

(*)

For heat pump space heaters and heat pump combination heaters, the rated heat output Prated is equal to the design load for heating Pdesignh, and the rated heat output of a supplementary heater Psup is equal to the supplementary capacity for heating sup(Tj).

(**)

If Cdh is not determined by measurement then the default degradation coefficient is Cdh = 0,9.


Turn static files into dynamic content formats.

Create a flipbook
ERP WWP LS 8 kW Væghængt varmepumpe by Max Weishaupt A/S - Issuu