AIRWAY MANAGEMENT CATALOGUE AIRWAY MANAGEMENT
Find our range of products on
www.vygon.com
Vygon in the world
OUR STORY Pierre Simonet founded Vygon in France in 1962. He was one of the first to introduce the concept of disposable medical equipment. Shortly thereafter, the company established subsidiaries in Europe, the United States, India, South America, and more. Today it is present worldwide. Vygon also relies on many production units, starting with its first plant in France and continuing on to its latest, brand-new plant that opened in Portugal in 2015.
Belgium Czech Republic Denmark Finland France Germany Ireland Italy Netherlands Norway Poland Portugal Spain Sweden Switzerland United Kingdom
R&D
Europe
Vygon is changing for you
Subsidiary Production
Today the company is present in 100 countries and works for 4,000 clients worldwide.
Office
We owe this rapid expansion to all of our clients, both old and new, and to our
Research and
employees’ capacity for innovation. Thanks to their commitment, we are able to offer
R&D Development
the products and devices that healthcare professionals expect, and that provide their patients with relief. We are also grateful for all of our employees' positive attitudes, whether they work in our laboratories, in our plants, or in our subsidiaries. Everyone is devoted to their jobs in the service of healthcare. Today, our development and our results have led us to prioritise an even more efficient approach for project management and to structure our activity in five business units.
Turkey
Since our product range is managed in a decentralised fashion, our staff members are able to concentrate on more specific projects, shorten the innovation cycles, and be
Europe
more responsive in managing their relations with you. Retaining the values, vocation, and professional approach that are unique to
United States
Japan
Algiers
Singapore
Vygon, and intensifying our inventive spirit, are the very objectives of this new organisational structure.
Dubai Colombia
India
Brazil
Stéphane Regnault CEO
Mauritius Uruguay
2
3
Contents
Non Invasive Ventilation ...........................................6
Tracheal And Bronchial Suctioning ......................... 34
Boussignac CPAP Range .......................................9 Boussignac CPAP Kits .........................................16
Tracheal suction tubes ...................................... 36 Mucus extractors .............................................. 39 Protected distal bronchial sampling .................. 42
Invasive Ventilation .................................................22 Thoracic Drainage ................................................... 43 Endotracheal tubes ..........................................24 Tracheostomy ...................................................26 Oropharyngeal airway ......................................27 Accessories ......................................................29
Thoracic drains ................................................. 44 Valves for thoracic drainage .............................. 47 Thoracic drainage sets ...................................... 48
Cardio Respiratory Resuscitation .............................30
Connectors ............................................................. 50
Boussignac CPR system ......................................32
4
5
Non Invasive Ventilation
6
7
Continuous positive airway pressure: Boussignac CPAP
Boussignac CPAP range
CPAP is the application of a Continuous Positive Airway Pressure in spontaneously breathing patients.
5570.13 Boussignac CPAP • Respiratory assistance device for spontaneously breathing patients allowing the maintenance in the airways of a pressure greater than atmospheric pressure during the entire respiratory cycle. • Pressure generator fitted with an extension tube (length 200cm) to connect to the oxygen supply and a connector for manometer.
Code
Length
Quantity box/case
5570.13
200 cm
5/60
5558.053 Manometer connecting tube Spare CPAP manometer (code 527.01) connecting tube.
Boussignac CPAP is a device for respiratory assistance for spontaneously breathing patients, enabling the continuous delivery of oxygen (or air) maintaining positive end expiratory pressure (PEEP) in the respiratory system. Boussignac CPAP is compatible with all face masks, endotracheal tubes and tracheostomy tubes (via a green adapter code 555.01) which comply with ISO 5356-1; it does not hinder the insertion of a suction catheter and can be used by a first aid worker as well as by a clinical specialist.
8
This device acts as a virtual valve, which is created by the acceleration of oxygen flow through the micro channels of the device. Boussignac CPAP is fitted with an integral oxygen connection tube. The translucent colourless port can be used for: • controlling the generated pressure (use the manometer connector) • monitoring EtCO2 • adding oxygen
Code
Length
Quantity box/case
5558.053
50 cm
10/240
9
555.01 22M - 15F / 22F connector
5557 Anaesthesia mask with adjustable air cushion
• Allows the connection of the Boussignac CPAP (code 5570.13) onto an endotracheal tube or tracheostomy tube of an intubed patient to help a respiratory function in recovery. • Allows the connection of an artificial nose (heat and moisture exchanger) to the Boussignac CPAP system to humidify ventilatory gases.
Disposable face mask, with inflatable cushion and colour code on the harness fixation ring. Non-sterile.
Quantity box/case : 20/240
884.06 vyconnector Allows the connection of the Boussignac CPAP to a source of air and a source of oxygen to modify the FiO2. Quantity box/case : 25/600
Vanilla scented
Scentless
Size
Correspond to body size
Connections mm
Colour code
Box/case
5557.45
5557.450
4
Adult - small
22 (female)
Yellow
5/50
5557.55
5557.550
5
Adult – medium
22 (female)
Green
5/50
5557.65
5557.650
6
Adult - large
22 (female)
Blue 5/50
5/50
Complete range can be found in the catalogue at www.vygon.com.
5558.62 Extension tube for ventilatory gases
5559.03 Fixation fabric harness for face mask
Length : 200 cm Diameter : 6 mm
The fixation fabric harness holds a face mask on the patient’s face and reduces the risk of leakage. Non sterile.
Quantity box/case : 10/120 Quantity box/case: 10/100 These head straps can be used with face masks size 3, 4, 5 and 6.
10
11
VBBNB31193 Nebulizer Device intended to aerosolize liquids into aerosol form in gases that are delivered directly to patient for breathing. An oxygen source is needed as power source for its function. Use 6 L / min of oxygen for drug particles between 2 to 4μm ensuring a broncho-alveolar spread. The nebulizer includes the following components: • 1 oxygen extension tube which must be connected to the recipient of the nebulizer • 1 recipient which contains the medication to be administered • 1 T connector Quantity box : 100
5566.01 5566.02 FiO2 Regulator device for Boussignac CPAP Code 5566.01: with 90° elbow to avoid the patient receiving a direct flow of oxygen in the eyes. Code 5566.02: without 90° elbow. Device which fits in between the facial mask and Boussignac CPAP and allows the FiO2 to be altered in emergency conditions when air is not available (pre-hospital care). Indeed, this product is perfectly adapted to COPD patients requiring ventilation assistance. Code 5566.01: Quantity box/case: 5/120 Code 5566.02: Quantity box/case: 5/45
5566.01
5566.02
5558.91 Boussignac CPAP Noise Reduction Device The Boussignac CPAP Noise Reduction Device is designed specifically to reduce the level of noise generated by the Boussignac CPAP Valve (reduction of around 6 decibels). The Boussignac CPAP Noise Reduction Device is designed to be used with all devices/products and kits that contain the Boussignac CPAP valve. The Boussignac CPAP Noise Reduction Device is a standalone accessory which can be added to any Boussignac CPAP valve and is well adapted for intra-hospital use. Quantity box/case: 10/480
12
13
Reusable devices Code 527.01 CPAP Manometer Manometer to measure the pressure generated by Boussignac CPAP in the patient's airways. The connecting tube is supplied in the packaging containing the Boussignac CPAP code 5570.13. The manometer must be connected to the translucent port on the CPAP device. It indicates each centimetre of H2O from 0 to 25cm. The manometer is encased in a protective housing and is supplied with a manometer lanyard. Quantity box/case: 1/50
O2 and Air flowmeters Flowmeter measuring the flow of oxygen/air up to 30 l/min. Inlet pressure: 4.5 bar (+/- 0.5 bar). Accuracy of measurements: +/-0,5 l/min or 10% of full scale.
5563.02 O2 flowmeter (Afnor) 5563.41 O2 flowmeter (BSI) 5563.42 O2 flowmeter (DIN) 5563.44 O2 flowmeter (Nordic)
5563.02
Quantity box/case:1/50
5563.01 Air flowmeter (Afnor) Quantity box/case: 1/24
5563.31 Air flowmeter (BSI) 5563.32 Air flowmeter (DIN) 5563.34 Air flowmeter (Nordic) Quantity box/case: 1/50
14
5563.31
15
Boussignac CPAP Kits Emergency Boussignac CPAP Kits 5562.802 (O2 flowmeter - AFNOR code 5563.02)
5562.842 (O2 flowmeter - DIN code 5563.42)
5562.841 (O2 flowmeter - BSI code 5563.41)
5562.700 (without flowmeter)
Kit designed for use in emergency situations (pre-hospital care) Quantity: 1
5577.013 Boussignac CPAP set and nebulizer (without mask) Contents of the set: • 1 Boussignac CPAP and manometer connector code 5570.13 • 1 nebulizer code VBBNB31193 Quantity box/case: 1/24
The Emergency Boussignac CPAP kit consists of: • 2 Boussignac CPAP with manometer connector code 5570.13 • 1 adult mask small size code 5557.45 • 1 adult mask medium size code 5557.55 • 1 adult mask large size code 5557.65 • 1 silicone harness code 5559.01
16
• 1 O2 Flowmeter code 5563.xx • 1 manometer code 527.01 • 1 syringe 20ml • 1 nebulizer code VBBNB93193 • 1 FiO2 regulator device code 5566.01
17
CPAP+ Set V08776615/06/16 CPAP+ Set
V08776605/13/07 CPAP+ Set With Noise Reduction Device
Contents of the set:
Contents of the set:
• 1 Boussignac CPAP with manometer connector (code 5570.13) • 1 NIV Facial Mask with integral harness, 3 sizes - V08776615 – Small - V08776606 – Medium - V08776616 - Large
• 1 Boussignac CPAP with manometer connector (code 5570.13) • 1 NIV Facial Mask with integral harness, 3 sizes - V08776605 - Small - V08776613 - Medium - V08776607 - Large • 1 Noise reduction device (code 5558.91)
Quantity box/case : 1/24
Quantity box/case : 1/24
V08776608/12/14 CPAP+ Set With FiO2 Regulator
V08776620/21/22 CPAP+ Set With Nebulizer
Contents of the set:
Contents of the set:
• 1 Boussignac CPAP with manometer connector (code 5570.13) • 1 NIV Facial Mask with integral harness, 3 sizes - V08776608 - Small - V08776612 - Medium - V08776614 - Large • 1 FiO2 regulator (code 5566.01)
• 1 Boussignac CPAP with manometer connector (code 5570.13) • 1 NIV Facial Mask with integral harness, 3 sizes - V08776620 - Small - V08776621 - Medium - V08776622 - Large • 1 Nebulizer with T connector and 1 extension tube (150 cm) (code VBBNB31193)
Quantity box/case : 1/24 Quantity box/case : 1/5
18
19
V08776623/24/25 CPAP+ Set With FiO2 Regulator and Noise Reduction Device
V08776609/10/11 Full CPAP+ Set
Contents of the set:
Contents of the set:
• 1 Boussignac CPAP with manometer connector (code 5570.13) • 1 NIV Facial Mask with integral harness, 3 sizes - V08776623 - Small - V08776624 - Medium - V08776625 - Large • 1 FiO2 regulator (code 5566.01) • 1 Noise reduction device (code 5558.91)
• 1 Boussignac CPAP with manometer connector (code 5570.13) • 1 NIV Facial Mask with integral harness, 3 sizes - V08776609 - Small - V08776610 - Medium - V08776611 - Large • 1 FiO2 regulator (code 5566.01) • 1 Noise reduction device (code 5558.91) • 1 Nebulizer with T connector and 1 extension tube (150 cm) (code VBBNB31193)
Quantity box/case : 1/5 Quantity box/case : 1/5
V08776626/27/28 Boussignac CPAP Protect Contents of the set: • 1 Boussignac CPAP with manometer connector (code 5570.13) • 1 NIV Facial Mask with integral harness, 3 sizes - V08776626 - Small - V08776627 - Medium - V08776628 - Large • 1 connector 22F/15F - 22M (code 555.01) • 1 Filtraflux HEPA filter (code 551.53) Quantity box/case : 1/5
20
21
Invasive Ventilation
22
23
Endotracheal tubes E.T. tubes with low pressure cuff General features of cuffed E.T. tubes: • Transparent PVC tube with XRO line • Oral / nasal intubation • 37° bevel • 15 mm adaptor • Low pressure cuff.
518 A Endotracheal tube Recommended for oral and nasal intubation.
514 514 K Endotracheal tube Code 514: soft tube, code 514 K: More rigid tube. Recommended for oral intubation
Tube Code
24
Length mm
Ext. Ø mm
Int. Ø mm
Fr
Quantity Box/case
514.50 (K)
518.50 A
300
7.0
5.0
21
20/160
514.55 (K)
518.55 A
300
8.0
5.5
24
20/160
514.60 (K)
518.60 A
300
8.5
6.0
26
20/160
514.65 (K)
518.65 A
300
9.0
6.5
27
20/160
514.70 (K)
518.70 A
325
10.0
7.0
30
20/160
514.75 (K)
518.75 A
325
10.5
7.5
32
20/160
514.80 (K)
518.80 A
325
11.0
8.0
33
20/160
514.85 (K)
518.85 A
325
11.7
8.5
35
20/160
514.90 (K)
518.90 A
325
12.5
9.0
38
20/160
514.95 (K)
518.95 A
325
13.0
9.5
39
20/160
514.10 (K)
-
325
13.5
10.0
40
20/160
25
Tracheostomy
Oropharyngeal airway
523 Tracheostomy tube
5576 bougie Boussignac
PVC tube with low-pressure cuff. Adjustable fixation collar.
Oro-tracheal flexible guide for difficult endotracheal intubation (Cormack superior to 2) with duct for oxygen injection and oxygen connector.
Quantity box/case: 1/90
bougie Boussignac features 2 ducts: • The first duct (transparent) is closed at the proximal end and open at the distal end. • The second duct (green, code 5576.01 or blue, code 5576.02) is open at the proximal end and closed at the distal end. An opening of the coloured duct at the coude level allows passage of the oxygen.The delivery of oxygen is confirmed by an audible whistle. In case of spasm, decompression openings will avoid any risk of barotrauma, allowing oxygen to pass out of the main tube. bougie Boussignac is available in 3 sizes (see neonatal bougie at www.vygon.com)
524 Montandon endotracheal tube PVC tube with low-pressure cuff. Quantity box/case: 20/160
Code
26
Tube
Tracheostomy
Montandon
Code 523 Length mm
523.26
524.26
110
8.5
6
26
523.30
524.30
115
10
7
30
523.33
524.33
125
11
8
33
Code
Size
Color
E.T. Internal Diameter
Length
Quantity box/case
523.36
524.36
135
12.5
9
38
5576.01
Adult
Green
6 to 11 mm
70 cm
10/40
523.39
524.39
145
13.5
10
40
5576.02
Paediatric
Blue
4 to 5.5 mm
60 cm
10/90
Ext. Ø mm
Int. Ø mm
Fr
27
Accessories Swivel connectors 5511 Guedel airway (EVA)
526.00 Rotating connector for endotracheal tube
Rounded atraumatic distal end. With bite-block to prevent occlusion. In accordance with ISO 5364, the size of an oropharyngeal airway is identified by its nominal length: see « L » expressed in millimetres.
Quantity box/case: 20/240
526.01 Rotating connector for bronchoscopy The silicone seal accepts bronchoscope diameters from 3.4 to 5.9 mm. Taper fittings: standard 15 mm Swivel on both the male and female taper allow greater patient movement. Quantity box/case: 20/240
(L)
Guedel airway Code
Traditional size
Size
Length mm
Colour code
Quantity Box/ case
528 Fixation collar for E.T. tube Adjustable fixation collar and fixation tape for endotracheal tube
Paediatrics 5511.30
000
3,5
36
Orange
20/960
5511.20
00
5
51
Blue
20/960
5511.10
0
6
61
Black
20/480
Adults
28
Code
For E.T. tube Int. Ø mm
Quantity Box/case
5511.01
1
8
77
Red
20/240
528.60
5.5 - 6
20/240
5511.02
2
9
94
Green
20/240
528.70
6.5 - 7
20/360
5511.03
3
10
100
White
20/240
528.80
7.5 - 8
20/360
5511.04
4
11
112
Yellow
20/240
528.90
8.5 - 9
20/360
29
Cardio Respiratory Resuscitation
30
31
Boussignac CPR system
6508 Boussignac CPR system The Boussignac CPR system is an endotracheal tube equipped with 5 microcapillaries for continuous insufflation of oxygen. During cardio-pulmonary resuscitation, the green extension tube is connected to a source of oxygen. When passing through the microcapillaries built within the wall of the endotracheal tube, the speed of injection of the oxygen is hugely accelerated. The 5 jets of gas exit at the distal end of the tube and the collision of these 5 jets creates a turbulence generating a « virtual valve ». Continuous insufflation of 15 L/min of oxygen through the microcapillaries generates a positive intra-pulmonary pressure. A single resuscitator can perform continuous external cardiac massage, as it is not necessary to interrupt cardiac massage for ventilation. Because there is no interruption of chest compressions, both cerebral perfusion pressure and coronary perfusion pressure are preserved. Oxygen enters passing through the microcapillaries, air (during the chest compression phase) exits passing the internal lumen of the tube, thus any risk of barotrauma due to non-synchronisation between the resuscitator performing chest compressions and the resuscitator ventilating the patient is avoided. Other benefits: • F acilitates the pulmonary mechanism of CO2 elimination and oxygenation without interrupting cardiac massage • I mproves overall hemodynamics by continuous supply of oxygenated blood to organs and tissues •P reservation of the functional residual capacity (FRC) allowing the prevention of alveolar collapse by insufflation of a constant flow of oxygen to keep the alveoli open. •P revention of rib and sternum fractures often caused by chest compressions. Characteristics of the Boussignac CPR system: - Transparent PVC tube with radiopaque line - 5 micro-capillaries for continuous intra-tracheal insufflation of oxygen - 1 capillary for inflating the low pressure cuff - 2 capillaries for capnometry and/or pressure monitoring and/or injection of medication - Green extension tube (200 cm long) to connect the device to the source of oxygen and fitted with an "anti-connection" device. In case of ROSC (return of spontaneous circulation), the green extension tube is removed and the lateral opening on the proximal adaptor can be occluded with the green cap provided. The proximal adaptor is a standard 15 mm male adaptor which allows to connect the Boussignac CPR system to a mechanical ventilator.
CPR Tube
32
Code
Length mm
Ext. Ø mm
Int. Ø mm
Ø of capillaries for oxygen adm.
Nb of capillaries for oxygen adm.
Quantity Box/ case
6508.70
325
10.0
7.0
0.65
5
1/20
6508.75
325
10.5
7.5
0.75
5
1/20
6508.80
325
11.0
8.0
0.85
5
1/20
33
Tracheal and Bronchial Suctioning
34
35
Tracheal suction tubes 530 70530 Suction tube - 46,5 cm
535 Control suction catheter (PVC) – 42 cm
Soft tube (PVC). Open, straight and rounded tip. Code 530: Fr 12 - 14 -16 -18. Large funnel without colour code. Code 70530: Fr 12 - 14 -16 -18. Large funnel with colour code.
Tracheal and bronchial suction catheter. Open tip. Proximal connector with lateral eye for finger tip control (with integral closing cap). Fr 12 - 14 - 16 - 18: Centimetre graduations from 5 to 20 cm. Length 42 cm
Quantity box/case: 50/600
Quantity box/case: 50/450
70545 Tracheal suction catheter - 46,5 cm
568 Coude suction catheter - 60 cm
PVC suction tube with open rounded tip and one lateral eye. Code 70545: Fr 12 - 14 - 16 - 18 and 20. Large funnel with colour code.
Fr 16 - 18. Quantity box/case: 50/450
Quantity box/case: 50/600
70565 Suction catheter- 56,5 cm Fr / Ch
4
5
6
7
8
10
12
14
16
18
20
Purple
Grey
Light green
Ivory
Blue
Black
White
Dark green
Orange
Red
Yellow
PVC tube with open, straight and rounded tip. Code 70565: Fr 12 - 14 - 16 - 18 and 20. Large funnel with colour code. Quantity box/case = 50/600
Color
See full range of suction tubes in the catalogue at www.vygon.com.
36
37
Mucus extractors 802 Connector for finger-tip suction control • Code 802.01: connector for finger-tip control of suction for suction catheters size 4 Fr, 5 Fr, 6 Fr, 7 Fr, 8 Fr* with small funnel connector. • Code 802.00: connector for finger-tip control of suction for suction catheters size 10 Fr* to 21Fr with large funnel connector. *Note: Code 530.10 and 533.10 (10Fr suction catheters) have a small funnel. Consequently with these 2 suction catheters connector code 802.01 must be used. These suction catheters can be found on the website www.vygon.com.
534 Mucus extractor 5534 Mucus extractor with screw cap Device for suctioning tracheal / bronchial secretions which will be analysed in laboratory. The mucus extractors include: • 1 tracheal suction tube Note 1: The mucus extractor code 5534.91 is supplied without suction catheter. Note 2: The mucus extractor code 5534.30 is supplied with 2 suction catheters (10 Fr - 33 cm and 6 Fr - 27 cm). • 1 PVC extension tube with small or large funnel to connect the mucus extractor to the suction source (code 534.xx only) • 1 separate lid for safe sealing and transport of the aspirate • 1 label.
534.14
5534.14
Connecting tube to suction source
Suction tube
38
Code
Vol. ml
534.91
Quantity Box/case
Length cm
Ext. Ø Fr
Length cm
Type of connector
25
-
-
13
Large funnel
25/150
534.20
70
57
10
50
Large funnel
15/120
534.14
25
33
14
47
Small funnel
25/150
534.16
25
50
16
52
Large funnel
20/120
5534.12
35
47
12
-
Small funnel
25/100
5534.14
35
47
14
-
Large funnel
25/100
Code
Quantity box/case
5534.30
35
27/33
6/10
-
-
25/100
802.00
20/480
5534.91
35
-
-
-
-
-
802.01
20/480
See full range of mucus extactors in the catalogue at www.vygon.com. 39
816.00 Adaptor for mucus extractor connection to a bronchoscope (male Luer / female Luer) Connector to fit a Luer syringe or mucus trap to a bronchoscope
536 Mucus extractor with adaptor for bronchoscopy 5536 Mucus extractor with screw cap with adaptor for bronchoscopy
Quantity box/case: 30/2880
Each pack contains a separate lid for safe sealing and transport of the aspirate. Supplied with an adaptor code 816 (see below) and a connecting tube for the vacuum source (code 536.xx only).
Protected distal bronchial sampling 538 aspisafe2
Double catheter for bronchoalveolar lavage for diagnosis of ventilator-associated pneumonia. The distal end of the external (radiopaque) catheter is closed by a polyethylene glycol plug allowing protected distal bronchial sampling.
While aspisafe2 code 538.25 is introduced blindly through an ET tube in the airways, aspisafe2 code 538.34 is inserted through the tubing of a bronchoscope for a precise sampling location in the lungs.
At the proximal end, there is a spacer between the external and internal catheters to avoid premature expulsion of the polyethylene glycol plug.
536.16
5536.16
Tubing Vol. ml
Connecting tube to suction source Length cm
Connecting tube to bronchoscope Length cm
Quantity Box/case
536.10
25
95
57
25/150
536.16
25
95
18
20/120
536.20
70
95
18
15/120
5536.10
35
-
59
25/100
5536.16
-
-
20
25/100
Code
40
Internal Catheter
External Catheter Fr
Length cm
Ext. Ø - Int. Ø mm
Fr
Quantity Box/case
1.7 - 1.0
5
60
2.7 - 2.0
8
20/300
1.3 - 0.9
4
90
1.9 - 1.4
6
20/300
Code
Length cm
Ext. Ø - Int. Ø mm
538.25
65
538.34
95
41
Thoracic Drainage
42
43
Thoracic drains
626 Thoracic trocar drain
636 Thoracic trocar drain - 28 cm
• Transparent PVC drain with radiopaque line • Open distal end and 2 lateral eyes • Funnel connector • Metallic trocar with handle ensuring a good grip and controlled insertion
• Transparent PVC drain with radiopaque line • Open distal end and 2 lateral eyes • Metallic trocar with handle ensuring a good grip and controlled insertion • Fixation disc
Fr 12 - 16: Length 25 cm Markings : every 2 cm from 2 to 14 cm
Fr 14 - 18 - 20 - 24 - 28 – 30 Markings at 5, 10 and 15 cm from the tip
Fr 20 - 24 - 28 - 32: Length 40 cm Markings: every 2 cm from 2 to 24 cm
Quantity box/case: 10/90
Quantity box/case: 20/180
635 Joly pleural drain - 15 cm • Transparent PVC drain with radiopaque line • Open distal end and 2 lateral eyes • Metallic trocar with handle ensuring a good grip and controlled insertion • Fixation disc Fr 12 - 14 – 18 Markings at 5, and 10 cm from the tip Quantity box/case: 10/180
44
45
Valves for thoracic drainage 681 easydrain
Valve body in flexible and transparent polyurethane with natural rubber sleeve in “duck's bill” shape acting as a non-return valve. This device is connected directly onto the patient's pleural or thoracic drain (adult, paediatric), or indirectly, using connector code 800.01 and an extension tube for neonates and infants.
easydrain is supplied with : - 1 introducer needle with integral handling sleeve - 1 radiopaque and transparent polyethylene drain with closed distal end. - 1 x 3-way stopcock and drain connector with silicone sleeve - 1 conical adaptor to connect Easydrain to drainage tubing. - Colour coded by size on handling sleeve and drain connector
Code 668.00: this two chamber device differs from the single valve code 669.10 in that it is possible to apply suction by manual compression of the compartment marked with an arrow.
Fr 06 : 1 mark at 10 cm and 2 marks at 13 cm Fr 082, Fr 08, Fr 10 : 1 mark at 12 cm and 2 marks at 22 cm
668.00 Dual valve for thoracic drainage Quantity box/case: 20/120
669.10 Single valve for thoracic drainage, Heimlich type Quantity box/case: 25/150
Thoracic drain
46
Code
Length cm
Ext. Ø mm
Fr
681.06
30
1.9
681.082
40
681.08 681.10
Needle G
Colour code -
Quantity Box/case
2.4
13
Green
10/90
77
3.3
10
Yellow
10/90
over 10cm
77
3.3
10
Red
10/90
over 10cm
77
4.0
8
Blue
10/90
Perforations
Length mm
Ext. Ø mm
6
over 3cm
57
2.7
8
over 4cm
50
2.7
8
50
3.3
10
47
Thoracic drainage sets 639 Complete tray for thoracic drainage Code 639.14 - Paediatric - Trocar drain code 636.14 Code 639.18 - Trocar drain code 636.18 Code 639.20 - Trocar drain code 636.20 Code 639.24 - Trocar drain code 636.24 Code 639.28 - Trocar drain code 636.28 Contents: - 1 trocar and radiopaque drain - 1 60x50cm fenestrated drape - 2 rectangular cups for detergent and disinfecting agents - 4 pads - 8 10x10cm gauze dressings - 2 dressing forceps - 2 10ml syringes - 1 38x1.2mm (18G) needle for drug aspiration - 1 15x0.5mm (25G) needle for skinwheal - 1 38x0.8mm (21G) needle for local anaesthesia - 1 90x1.2mm (18G) needle for emergency exsufflation (38mmx0.9mm (20G) for codes 639.08 and 639.14) - 2 suture needles - 1 scalpel - 1 dual suction valve - 1 plastic bag with connector for collecting the drained liquid - 1 coil of adhesive bandage, 75mm wide - 1 pair of gloves. Quantity box/case: 1/8 Neonatal tray for thoracic drainage code 639.08 can be found in the catalogue at www.vygon.com.
48
49
881 Straight double taper connector and adaptor
Connectors
50
Connector Ext. Ø mm
Quantity Box/case
881.11
10 - 13 / 10 - 13
30/1440
881.13
13.5 - 16 / 13.5 - 16
30/1440
881.30
13.5 - 15.5 / 10 - 12
30/1440
881.31
3 - 5 / 10 - 13
30/1440
881.33
3-5/3-5
30/2880
881.35
13.5 - 15.5 / 5.5 - 7
30/1440
881.37
7 - 10 / 3 - 5
30/2880
881.44
4-6/4-6
30/2880
881.47
7 - 10 / 4 - 6
30/2880
881.51
5 - 7 / 10 13
30/1440
881.53
13.5 - 15.5 / 3.5 - 5.0
30/1440
881.57
13.5 - 15.5 / 7.5 - 9
30/1440
881.66
6-8/6-8
30/2880
881.71
7 - 10 / 10 - 13
30/1440
881.77
7 - 9.5 / 7 - 9.5
30/2880
Code
51
884 “Y” connector
881.00 Universal straight double taper connector and adaptor Universal straight double taper connector
Code 881.00
52
Connector Ext. Ø mm 7,8 - 15,7 / 7,8 -15,7
Connector Ext. Ø mm
Quantity Box/case
884.04
4–6
30/1440
884.06
6–8
25/600
884.08
8 – 10
30/720
884.12
12 – 14
30/270
884.16
16 – 18
30/270
Code
Quantity Box/case 30/540
53
03/2022 - DC URGE 20 561 E
PAIN & AIRWAY MANAGEMENT For further information, please contact: questions@vygon.com The specifications shown in this catalogue are for information only and are not, under any circumstances, of a contractual nature.
Vygon – 5, rue Adeline • 95440 ECOUEN • FRANCE Reception: +33 (0)1.39.92.63.63 – Service clients France: +33 (0)1.39.92.63.81 Export customer service: +33 (0)1.39.92.64.15 Fax.: +33 (0)1.39.92.64.44 • www.vygon.com
www.vygon.com