Code Analysis

Occupancy type: Assembly (A-3), Mercantile

Assembly occupant load: 221

Advertisement

Mercantile occupant load: 5

Allowable building height: 75 feet

Plumbing fixtures requirements: water closets (male – 1 per 125, female 1 per 65), lavatories – 1 per 200

Drinking fountain – 1 per 500, must be located within a distance of travel of 500 feet of the most remote location in the tenant space (covered or open mall – 300 feet), shall be located on an accessible route

Signage for each sex for toilet facilities

Circulation paths of means of egress – must be a slip-resistant surface

An emergency voice/alarm communication system is required

An automatic sprinkler system shall be provided for occupancy Group A, not needed for occupancy Group M