FOLD METAL PANEL RAILING SYSTEM PRODUCT DATA ™

FOLD - AVAILABLE INFILLS Laser Cut Patterns

151 W. Vista Ridge Mall Dr. Lewisville, TX 75067

972-353-8482

info@vivarailings.com

vivarailings.com


FOLD METAL PANEL RAILING SYSTEM ™

Our Fold Panel Railing System is an ingeniously engineered structural sheet metal fabrication design. This system features CNC laser cut patterns that provide a range of pre-configured or custom designs of your choice. With material choices of aluminum or steel in finishes of anodized or powder coating – what you can do with the FOLD panel system on your project is best left to your imagination.

FOLD - AVAILABLE INFILLS

FOLD-11/11/22

Laser Cut Patterns

Other mounting options available.

2

151 W. Vista Ridge Mall Dr. Lewisville, TX 75067

972-353-8482

info@vivarailings.com

vivarailings.com


FOLD METAL PANEL SYSTEM - TECHNICAL DATA ™

MATERIAL

Stainless Steel (201) / Aluminum (With Stainless Steel infill panel)

POST Stainless Steel (304 or 316) (With Stainless Steel infill panel)

FINISH

SIZE/SPACING

Powder Coat Formed panels @ 4’-6” max. O.C. #6 Satin, #8 Mirror

Fascia, Top or Core mount.

ECM

#6 Satin Stainless Steel (304 or 316)

ECM Powder Coat - Super Polyester (AAMA 2604) - $ ¹

INFILL OPTIONS

Powder Coat - Super Polyester (AAMA 2604) - $

2” wide with 14GA thickness. 4’-0” max. O.C.

Aluminum Powder Coat - PVDF (AAMA 2605) - $$

HAND RAIL

Steel

Powder Coat

Stainless Steel Tube

#6 Satin, Powder Coat

Ø1-1/2” or Ø2” tube

Stainless Steel Tube with LED ²

#6 Satin

Ø1-1/2” with LED LINEAR, Ø1-1/2” or Ø2” with LED POD

Wood (Red Oak, Cherry or Maple) ³

Ø2” 1. $ to $$$: Indicates finish type comparative cost.

Unstained Wood (Red Oak, Cherry or Maple) with LED

Ø2” with LED LINEAR

2. All LED LINEAR products are ETL certified; ETL mark is proof of product compliance to North American safety standard. 3. Other species available upon request.

151 W. Vista Ridge Mall Dr. Lewisville, TX 75067

972-353-8482

info@vivarailings.com

vivarailings.com

3


I V A

FOLD RAILING SYSTEM

151 W. VISTA RIDGE MALL Dr. LEWISVILLE, TX 75067 P: 972-353-8482 F: 972-353-0013 e: info@vivarailings.com www.vivarailings.com

Page 2 of 4 12/18/2023

FOLD RAILING SYSTEM Fold Panel METAL PANEL INFILL

4'-6" MAX

4'-6" MAX

3 8" NOM. GAP

1" 12 MARGIN

Visit https://vivarailings.com/ for range of design patterns Or provide your custom pattern

2"

2"

FOLD PANEL

FOLD PANEL

HAND RAIL

HAND RAIL

3'-0" 3'-7"

3'-0" 3'-7"

HAND RAIL

FOLD POST

1 4" NOM. GAP

FINISH FLOOR

2" NOM.

FINISH FLOOR

FOLD POST

1'-0"

FOLD POST

STRINGER

STRINGER

FOLD PANEL

SECTION

LEVEL 1 0'-0"

SLAB COVERED FASCIA SECTION

1'-0" VIVA RAILINGS IS NOT RESPONSIBLE FOR THE STRUCTURAL INTEGRITY OF ANY BUILDING SYSTEMS OR OTHER MATERIALS NOT FURNISHED BY VIVA RAILINGS. VIVA RAILINGS HAS NO WAY OF KNOWING AND SPECIFICALLY DISCLAIMS WHETHER OR NOT THE BUILDING SYSTEMS TO WHICH VIVA RAILINGS' PRODUCTS ARE TO BE ATTACHED ARE STRUCTURALLY SOUND OR DESIGNED TO PROPERLY SUPPORT VIVA RAILINGS'S MATERIALS. ANY SUCH DESIGN RESPONSIBILITY BELONGS TO OTHERS FOR WHOM VIVA RAILINGS IS NOT RESPONSIBLE. ARE FOR INTENDED FOR INTEGRITY THE SOLE USE OF VIVA RAILINGS' THEIR AGENTS FOR THE INSTALLATION OF PRODUCTS FURNISHED BY VIVAORRAILINGS. VIVA RAILINGS REMAINS THEPRODUCTS SOLE OWNER ALL DESIGNS AND INTELLECTUAL CONTAINED WITHIN. VIVATHESE RAILINGSDRAWINGS IS NOT RESPONSIBLE THE STRUCTURAL OF ANY BUILDING SYSTEMS OR OTHERCUSTOMER MATERIALS NOT AND FURNISHED BY VIVA RAILINGS. VIVA RAILINGS HAS NO WAY OF KNOWING AND SPECIFICALLY DISCLAIMS WHETHER NOT THE BUILDING SYSTEMS TO WHICH VIVA RAILINGS’ ARE TO BEOF ATTACHED ARE STRUCTURALLY SOUND OR DESIGNEDPROPERTY TO PROPERLY SUPPORT VIVAREPRODUCTION RAILINGS’S MATERIALS.AND ANY SUCH RESPONSIBILITY BELONGS TOANY OTHERS FOR WHOM VIVA RAILINGS IS NOT RESPONSIBLE. THESE DRAWINGS ARE INTENDEDFOR FOR THE SOLE USE OF VIVA RAILINGS’ CUSTOMER AND THEIR AGENTS FOR THEAND INSTALLATION OF PRODUCTS FURNISHED BY VIVA RAILINGS. VIVA RAILINGS REMAINS THE SOLE OWNER OF ALL DESIGNS AND INTELLECTUAL PROPERTY USEDESIGN OF THESE DESIGNS FOR OTHER PURPOSE IS FORBIDDEN. SCALES ARE PROVIDED REFERENCE ONLY. FOR PRODUCT INFORMATION TECHNICAL SUPPORT, PLEASE CONTACT VIVA RAILINGS. CONTAINED WITHIN. REPRODUCTION AND USE OF THESE DESIGNS FOR ANY OTHER PURPOSE IS FORBIDDEN. SCALES ARE PROVIDED FOR REFERENCE ONLY. FOR PRODUCT INFORMATION AND TECHNICAL SUPPORT, PLEASE CONTACT VIVA RAILINGS.

4

151 W. Vista Ridge Mall Dr. Lewisville, TX 75067

972-353-8482

info@vivarailings.com

vivarailings.com


FOLD METAL PANEL RAILING SYSTEM

151 W. Vista Ridge Mall Dr. Lewisville, TX 75067

972-353-8482

info@vivarailings.com

vivarailings.com

5


TM

V I V A

VIVA RAILINGS, LLC

FOLD RAILING SYSTEM

151 W. VISTA RIDGE MALL Dr. LEWISVILLE, TX 75067

FOLD RAILING SYSTEM

P: 972-353-8482 F: 972-353-0013 e: info@vivarailings.com www.vivarailings.com

Page 3.1 of 4 12/18/2023

5" MIN.

5" MIN.

Mounting Condition, TopPOST Mounted Post MOUNTING CONDITION, TOP MOUNTED

6" MIN.

7" MIN. 3" MIN.

Anchored to Concrete ¹ - $ ²

Cored into Concrete - $$

Welded @ Steel Channel - $

Detail# FO-T01

Detail# FO-T02

Detail# FO-T03

4" MIN.

3" 64 MIN.

3" MIN.

5" MIN.

Embed Plate (By others)

Welded @ Embed Plate - $

Anchored to Concrete Slab on Deck - $$

Detail# FO-T04

Detail# FO-T05

(1) Min. 4000 PSI concrete, Typ. (2) $ to $$$: Indicates mounting type comparative cost VIVA RAILINGS IS NOT RESPONSIBLE FOR THE STRUCTURAL INTEGRITY OF ANY BUILDING SYSTEMS OR OTHER MATERIALS NOT FURNISHED BY VIVA RAILINGS. VIVA RAILINGS HAS NO WAY OF KNOWING AND SPECIFICALLY DISCLAIMS WHETHER OR NOT THE BUILDING SYSTEMS TO WHICH VIVA VIVA RAILINGS IS NOT RESPONSIBLE FOR THE STRUCTURAL INTEGRITY OF ANY BUILDING SYSTEMS OR OTHER MATERIALS NOT FURNISHED BY VIVA RAILINGS. VIVA RAILINGS HAS NO WAY OF KNOWING AND SPECIFICALLY DISCLAIMS WHETHER OR NOT THE BUILDING SYSTEMS TO WHICH VIVA RAILINGS’ PRODUCTS ARE TO BE ATTACHED ARE STRUCTURALLY SOUND OR DESIGNED TO PROPERLY SUPPORT RAILINGS' PRODUCTS TODESIGN BE ATTACHED ARE STRUCTURALLY SOUND DESIGNED TO PROPERLY SUPPORT VIVA RAILINGS'S MATERIALS. ANY SUCH DESIGN RESPONSIBILITY BELONGS TO OTHERS FOR WHOM VIVA IS NOT RESPONSIBLE. VIVA RAILINGS’S MATERIALS. ARE ANY SUCH RESPONSIBILITY BELONGS TO OTHERS FOR WHOM VIVA OR RAILINGS IS NOT RESPONSIBLE. THESE DRAWINGS ARE INTENDED FOR THE SOLE USE OF VIVA RAILINGS’ CUSTOMER AND THEIR AGENTS FOR THE INSTALLATION OF PRODUCTS FURNISHED BY VIVA RAILINGS. VIVARAILINGS RAILINGS REMAINS THE SOLE OWNER OF ALL DESIGNS AND INTELLECTUAL PROPERTY THESE DRAWINGS ARE INTENDED FOR THE SOLE USE VIVA RAILINGS' CUSTOMER THEIR THEPRODUCT INSTALLATION FURNISHED BY VIVA VIVA RAILINGS REMAINS THE SOLE OWNER OF ALL DESIGNS AND INTELLECTUAL PROPERTY CONTAINED WITHIN. CONTAINED WITHIN. REPRODUCTION AND USE OF THESE DESIGNS FOR ANY OF OTHER PURPOSE IS FORBIDDEN. SCALES AREAND PROVIDED FORAGENTS REFERENCEFOR ONLY. FOR INFORMATIONOF ANDPRODUCTS TECHNICAL SUPPORT, PLEASE CONTACT VIVA RAILINGS. RAILINGS. REPRODUCTION AND USE OF THESE DESIGNS FOR ANY OTHER PURPOSE IS FORBIDDEN. SCALES ARE PROVIDED FOR REFERENCE ONLY. FOR PRODUCT INFORMATION AND TECHNICAL SUPPORT, PLEASE CONTACT VIVA RAILINGS.

6

151 W. Vista Ridge Mall Dr. Lewisville, TX 75067

972-353-8482

info@vivarailings.com

vivarailings.com


V I V A

FOLD RAILING SYSTEM

151 W. VISTA RIDGE MALL Dr. LEWISVILLE, TX 75067 P: 972-353-8482 F: 972-353-0013 e: info@vivarailings.com www.vivarailings.com

FOLD RAILING SYSTEM

Page 3.2 of 4 12/18/2023

Mounting Condition, Fascia Mounted Post MOUNTING CONDITION, FASCIA MOUNTED POST

6"

6" MIN.

6"

6" MIN.

Embed Plate (By others)

Detail# FO-F01

Detail# FO-F02

6"

6"

6"

Welded @ Embed Plate - $$

6"

Anchored to Concrete ¹ - $$$

Welded @ Steel Channel - $$

Welded @ Steel Tube - $$

Detail# FO-F03

Detail# FO-F04

(1) Min. 4000 PSI concrete, Typ. VIVA RAILINGS IS NOT RESPONSIBLE FOR THE STRUCTURAL INTEGRITY OF ANY BUILDING SYSTEMS OR OTHER MATERIALS NOT FURNISHED BY VIVA RAILINGS. VIVA RAILINGS HAS NO WAY OF KNOWING AND SPECIFICALLY DISCLAIMS WHETHER OR NOT THE BUILDING SYSTEMS TO WHICH VIVA RAILINGS' PRODUCTS ARE TO BE ATTACHED ARE STRUCTURALLY SOUND OR DESIGNED TO PROPERLY SUPPORT VIVA RAILINGS'S MATERIALS. ANY SUCH DESIGN RESPONSIBILITY BELONGS TO OTHERS FOR WHOM VIVA RAILINGS IS NOT RESPONSIBLE. VIVATHESE RAILINGSDRAWINGS IS NOT RESPONSIBLE THE STRUCTURAL OF ANY BUILDING SYSTEMS OR OTHERCUSTOMER MATERIALS NOT AND FURNISHED BY VIVA RAILINGS.FOR VIVA RAILINGS HAS NO WAY OF KNOWING AND SPECIFICALLY DISCLAIMS WHETHER NOT THE BUILDING SYSTEMS TO WHICH VIVA RAILINGS’ ARE TO BEOF ATTACHED ARE STRUCTURALLY SOUND OR DESIGNEDPROPERTY TO PROPERLY SUPPORT AREFOR INTENDED FOR INTEGRITY THE SOLE USE OF VIVA RAILINGS' THEIR AGENTS THE INSTALLATION OF PRODUCTS FURNISHED BY VIVAORRAILINGS. VIVA RAILINGS REMAINS THEPRODUCTS SOLE OWNER ALL DESIGNS AND INTELLECTUAL CONTAINED WITHIN. VIVAREPRODUCTION RAILINGS’S MATERIALS.AND ANY SUCH RESPONSIBILITY BELONGS TOANY OTHERS FOR WHOM VIVA RAILINGS NOT RESPONSIBLE. THESE DRAWINGS ARE INTENDEDFOR FOR THE SOLE USE OF VIVA RAILINGS’ CUSTOMER AND THEIR AGENTS FOR THEAND INSTALLATION OF PRODUCTS FURNISHED BY VIVA RAILINGS. VIVA RAILINGS REMAINS THE SOLE OWNER OF ALL DESIGNS AND INTELLECTUAL PROPERTY USEDESIGN OF THESE DESIGNS FOR OTHER PURPOSE IS IS FORBIDDEN. SCALES ARE PROVIDED REFERENCE ONLY. FOR PRODUCT INFORMATION TECHNICAL SUPPORT, PLEASE CONTACT VIVA RAILINGS. CONTAINED WITHIN. REPRODUCTION AND USE OF THESE DESIGNS FOR ANY OTHER PURPOSE IS FORBIDDEN. SCALES ARE PROVIDED FOR REFERENCE ONLY. FOR PRODUCT INFORMATION AND TECHNICAL SUPPORT, PLEASE CONTACT VIVA RAILINGS.

151 W. Vista Ridge Mall Dr. Lewisville, TX 75067

972-353-8482

info@vivarailings.com

vivarailings.com

7


TM

V I V A

VIVA RAILINGS, LLC

FOLD RAILING SYSTEM

151 W. VISTA RIDGE MALL Dr. LEWISVILLE, TX 75067

FOLD RAILING SYSTEM

P: 972-353-8482 F: 972-353-0013 e: info@vivarailings.com www.vivarailings.com

Page 4 of 4 12/18/2023

Illuminated Railing ILLUMINATED RAILING

30° ASYM. LINEAR

SYM. LINEAR

INFILL PANEL

iRAIL Linear

SYM. POD

1" 24

ILLUMINATED HANDRAIL 36" TO FF

iRAIL LINEAR ORIENTATION OPTIONS

22° ASYM. POD

1" Ø12

Illuminated Handrail Option

18" 24" OR 36"

POD

iRAIL POD ORIENTATION OPTIONS

iRAIL POD SPACING OPTIONS

See Viva iRail Railing System for more info

iRAIL LIGHTED RAILING SYSTEM 8

151 W. Vista Ridge Mall Dr. Lewisville, TX 75067

972-353-8482

info@vivarailings.com

vivarailings.com


FOLD METAL PANEL RAILING SYSTEM

151 W. Vista Ridge Mall Dr. Lewisville, TX 75067

972-353-8482

info@vivarailings.com

vivarailings.com

9


FOLD METAL PANEL RAILING SYSTEM TARRANT COUNTY COLLEGE - NW CAMPUS

TCC NORTHWEST CAMPUS - FT. WORTH, TX General Contractor: Skanska USA Building Architect: Huckabee Architects

10

151 W. Vista Ridge Mall Dr. Lewisville, TX 75067

972-353-8482

info@vivarailings.com

vivarailings.com


FOLD METAL PANEL RAILING SYSTEM LEWISVILLE ISD CAREER TRAING CENTER

LEWISVILLE ISD CAREER TRAINING CENTER - LEWISVILLE, TX General Contractor: Northstar Builders Group Architect: Stantec Corporation

151 W. Vista Ridge Mall Dr. Lewisville, TX 75067

972-353-8482

info@vivarailings.com

vivarailings.com

11


NORTH AMERICA OPERATIONS

New York, NY Washington DC Kansas City, KS

151 W. Vista Ridge Mall Dr. Lewisville, TX 75067

San Diego, CA

Atlanta, GA

(Dallas/Fort Worth Metroplex)

Dallas/Fort Worth, TX

PH: 972.353.8482 | info@vivarailings.com vivarailings.com

Orlando, FL Regional Locations

Inc. Magazine 500 | 5000 VIVA RAILINGS, LLC. Among The Fastest Growing US Companies Eight Years in a Row 2012-2019

Inc. Magazine 500 | 5000 VIVA RAILINGS, LLC. Among The Fastest Growing Texas Companies #211

ICC-ES 4405 Certified

SHOE™ Structural Glass Railing System

LEED Material & Resources Credits 4.1 and 4.2

The American Institute of Architects

The California Contractors State License Board Certified

Version:01.22.2024


Turn static files into dynamic content formats.

Create a flipbook
FOLD METAL PANEL Product Data by viva.railings - Issuu