CIRCA Perf Product Data

Page 1

info@vivarailings.com 151 W. Vista Ridge Mall Dr. Lewisville, TX 75067 972-353-8482 vivarailings.com CIRCA™ PERF RAILING SYSTEM PRODUCT DATA Perforated Metal Glass CIRCA - AVAILABLE INFILLS Wire Mesh Picket Panel CableNet Multiline Cable Laser Cut Panel

Picket

CableNet

Multiline

Cable

2 CIRCA™ PERF RAILING SYSTEM CIRCA PERF -11/11/22 info@vivarailings.com 151 W. Vista Ridge Mall Dr. Lewisville, TX 75067 972-353-8482 vivarailings.com
CIRCA - AVAILABLE INFILLS
Perforated Metal Glass
Wire Mesh
Panel
Panel
Laser Cut
Other mounting options available.
provides
Our CIRCA Stainless Steel Railing System
a simple yet timeless look. The system consists of round tubular posts and the railing in-fill between the posts is mounted via fixed point holders.

CIRCA™

GLASS & METAL SYSTEM - TECHNICAL DATA

MATERIAL FINISH SIZE/SPACING

Stainless Steel (304 or 316)

POST INFILL OPTIONS

#6 Satin, #8 Mirror

ECM

Powder Coat Stainless Steel (201)

Ø2” @ 5’-0” max. O.C.

4’-6” max. for perforated and wire mesh infill.

4’-0” max. for Multiline and cable infill.

Fascia, Top or Core mount.

TOP RAIL/HAND RAIL

ECM finish is not available for U-cap, top rail or hand rail.

Glass Clear, Tinted or Frit

Perforated Metal

Wire Mesh

Min. 3/8” laminated glass with PVB or SGP interlayer ¹

Glass standard thickness: 3/8”, 1/2”, 5/8”, 3/4”

Interlayer standard thickness: SGP: 0.035” 0.06”

PVB: 0.035”

1” wide frame

Picket Panel Ø1/2” picket

#6 Satin

Multiline

Cable

CableNet

Powder Coat - Super Polyester (AAMA 2604) - $ 4

Ø1/2” multiline

Ø1” Wide frame, Ø1/16” (1.5mm) cable mesh

Laser Cut 1/4” thick aluminum panel.

Powder Coat - PVDF (AAMA 2605) - $$

#6 Satin, Powder Coat Ø3/16” cable

Stainless Steel Tube Ø1-1/2” or Ø2” for Hand Rail Ø1-1/2”, Ø2” or 2”x1” Rectangular tube for Top Rail

Stainless Steel Tube with LED ²

Wood (Red Oak, Cherry or Maple) ³

Wood (Red Oak, Cherry or Maple) with LED

#6 Satin

Unstained Ø1-1/2” with LED LINEAR, Ø1-1/2” or Ø2” with LED POD

Ø2” Ø2” with LED LINEAR

1. IBC 2015 & newer requires railing glass to be laminated. VIVA recommends SGP for exterior applications.

2. All LED LINEAR products are ETL certified; ETL mark is proof of product compliance to North American safety standard.

3. Other species available upon request.

4. $ to $$$: Indicates finish type comparative cost.

3
info@vivarailings.com 151 W. Vista Ridge Mall Dr. Lewisville, TX 75067 972-353-8482 vivarailings.com

Perforated Metal Infill

TOP RAIL

HAND RAIL

PMRO-0610 PMRO-1014

PMSQ-1013 PMRO-1217

TOP RAIL

PMSL-0325

PERFORATED METAL

HAND RAIL

PMSL-1122

CIRCA POST

PERFORATED METAL

VIVA RAILINGS IS NOT RESPONSIBLE FOR THE STRUCTURAL INTEGRITY OF ANY BUILDING SYSTEMS OR OTHER MATERIALS NOT FURNISHED BY VIVA RAILINGS. VIVA RAILINGS HAS NO WAY OF KNOWING AND SPECIFICALLY DISCLAIMS WHETHER OR NOT THE BUILDING SYSTEMS TO WHICH VIVA RAILINGS' PRODUCTS ARE TO BE ATTACHED ARE STRUCTURALLY SOUND OR DESIGNED TO PROPERLY SUPPORT VIVA RAILINGS'S MATERIALS. ANY SUCH DESIGN RESPONSIBILITY BELONGS TO OTHERS FOR WHOM VIVA RAILINGS IS NOT RESPONSIBLE. THESE DRAWINGS ARE INTENDED FOR THE SOLE USE OF VIVA RAILINGS' CUSTOMER AND THEIR AGENTS FOR THE INSTALLATION OF PRODUCTS FURNISHED BY VIVA RAILINGS. VIVA RAILINGS REMAINS THE SOLE OWNER OF ALL DESIGNS AND INTELLECTUAL PROPERTY CONTAINED WITHIN. REPRODUCTION AND USE OF THESE DESIGNS FOR ANY OTHER PURPOSE IS FORBIDDEN. SCALES ARE PROVIDED FOR REFERENCE ONLY. FOR PRODUCT INFORMATION AND TECHNICAL SUPPORT, PLEASE CONTACT

4
1'-0" 1'-0"
STRINGER
2" NOM. 3" NOM. 1" 13 4 " 5 16 " 1 8 " 9 16 11 16 " 3 8 " 5 8 7 16 " 13 16 " 7 8 " 1 1 16 " 9 16 " 1" 1 16 (14 GA)
V V A TM
31 2 "
CIRCA RAILING SYSTEM
NOM. GAP
MAX 4'-6" MAX
SECTION VIEW 4'-6"
VIVA RAILINGS. R4" LEVEL 1 0'-0" FINISH FLOOR 3'-0" 3'-6" TOP RAIL OPTIONS Ø2" TUBE Ø1-1/2" TUBE 2"x1" TUBE Ø1-1/2" iRAIL VIVA RAILINGS, LLC 151 W. VISTA RIDGE MALL Dr. LEWISVILLE, TX 75067 P: 972-353-8482 F: 972-353-0013 e: info@vivarailings.com www.vivarailings.com SPIDER CLAMP AVAILABLE PERFORATED TYPES: Ø3 8 " Ø1 2 " Ø 1 4 3 8 " Page 2.2 OF 5 12/4/2023 info@vivarailings.com 151 W. Vista Ridge Mall Dr. Lewisville, TX 75067 972-353-8482 vivarailings.com CIRCA RAILING SYSTEM PERFORATED METAL INFILL VIVA RAILINGS IS NOT RESPONSIBLE FOR THE STRUCTURAL INTEGRITY OF ANY BUILDING SYSTEMS OR OTHER MATERIALS NOT FURNISHED BY VIVA RAILINGS. VIVA RAILINGS HAS NO WAY OF KNOWING AND SPECIFICALLY DISCLAIMS WHETHER OR NOT THE BUILDING SYSTEMS TO WHICH VIVA RAILINGS’ PRODUCTS ARE TO BE ATTACHED ARE STRUCTURALLY SOUND OR DESIGNED TO PROPERLY SUPPORT VIVA RAILINGS’S MATERIALS. ANY SUCH DESIGN RESPONSIBILITY BELONGS TO OTHERS FOR WHOM VIVA RAILINGS IS NOT RESPONSIBLE. THESE DRAWINGS ARE INTENDED FOR THE SOLE USE OF VIVA RAILINGS’ CUSTOMER AND THEIR AGENTS FOR THE INSTALLATION OF PRODUCTS FURNISHED BY VIVA RAILINGS. VIVA RAILINGS REMAINS THE SOLE OWNER OF ALL DESIGNS AND INTELLECTUAL PROPERTY CONTAINED WITHIN. REPRODUCTION AND USE OF THESE DESIGNS FOR ANY OTHER PURPOSE IS FORBIDDEN. SCALES ARE PROVIDED FOR REFERENCE ONLY. FOR PRODUCT INFORMATION AND TECHNICAL SUPPORT, PLEASE CONTACT VIVA RAILINGS. AVAILABLE PERFORATED TYPES TOP RAIL OPTIONS

Glass Infill

Clear Laminated (PVB or SGP)

Clear Monolithic

TOP RAIL 5'-0"

Ceramic Frit

Colored Laminate (PVB only)

Bent Tinted Satin Etched

LAMINATED GLASS

HAND RAIL

TOP RAIL

HAND RAIL

FINISH FLOOR

CIRCA

LAMINATED

5
1 0'-0"
LEVEL
MAX
MAX
5'-0"
1'-0" 1'-0"
3'-6"
3'-0"
GLASS
STRINGER
POST
2" NOM. 3" NOM.
V V A TM I
1 2 " NOM. GAP VIVA RAILINGS IS NOT RESPONSIBLE FOR THE STRUCTURAL INTEGRITY OF ANY BUILDING SYSTEMS OR OTHER MATERIALS NOT FURNISHED BY VIVA RAILINGS. VIVA RAILINGS HAS NO WAY OF KNOWING AND SPECIFICALLY DISCLAIMS WHETHER OR NOT THE BUILDING SYSTEMS TO WHICH VIVA RAILINGS' PRODUCTS ARE TO BE ATTACHED ARE STRUCTURALLY SOUND OR DESIGNED TO PROPERLY SUPPORT VIVA RAILINGS'S MATERIALS. ANY SUCH DESIGN RESPONSIBILITY BELONGS TO OTHERS FOR WHOM VIVA RAILINGS IS NOT RESPONSIBLE. THESE DRAWINGS ARE INTENDED FOR THE SOLE USE OF VIVA RAILINGS' CUSTOMER AND THEIR AGENTS FOR THE INSTALLATION OF PRODUCTS FURNISHED BY VIVA RAILINGS. VIVA RAILINGS REMAINS THE SOLE OWNER OF ALL DESIGNS AND INTELLECTUAL PROPERTY CONTAINED WITHIN. REPRODUCTION AND USE OF THESE DESIGNS FOR ANY OTHER PURPOSE IS FORBIDDEN. SCALES ARE PROVIDED FOR REFERENCE ONLY. FOR PRODUCT INFORMATION AND TECHNICAL SUPPORT, PLEASE CONTACT VIVA RAILINGS. R4" TOP RAIL OPTIONS Ø2" TUBE Ø1-1/2" TUBE
TUBE
iRAIL AVAILABLE GLASS TYPES: SPIDER CLAMP VIVA RAILINGS, LLC 151 W. VISTA RIDGE MALL Dr. LEWISVILLE, TX 75067 P: 972-353-8482 F: 972-353-0013 e: info@vivarailings.com www.vivarailings.com Page 2.1 OF 5 12/4/2023 AVAILABLE GLASS TYPES CIRCA RAILING SYSTEM GLASS INFILL info@vivarailings.com 151 W. Vista Ridge Mall Dr. Lewisville, TX 75067 972-353-8482 vivarailings.com VIVA RAILINGS IS NOT RESPONSIBLE FOR THE STRUCTURAL INTEGRITY OF ANY BUILDING SYSTEMS OR OTHER MATERIALS NOT FURNISHED BY VIVA RAILINGS. VIVA RAILINGS HAS NO WAY OF KNOWING AND SPECIFICALLY DISCLAIMS WHETHER OR NOT THE BUILDING SYSTEMS TO WHICH VIVA RAILINGS’ PRODUCTS ARE TO BE ATTACHED ARE STRUCTURALLY SOUND OR DESIGNED TO PROPERLY SUPPORT VIVA RAILINGS’S MATERIALS. ANY SUCH DESIGN RESPONSIBILITY BELONGS TO OTHERS FOR WHOM VIVA RAILINGS IS NOT RESPONSIBLE. THESE DRAWINGS ARE INTENDED FOR THE SOLE USE OF VIVA RAILINGS’ CUSTOMER AND THEIR AGENTS FOR THE INSTALLATION OF PRODUCTS FURNISHED BY VIVA RAILINGS. VIVA RAILINGS REMAINS THE SOLE OWNER OF ALL DESIGNS AND INTELLECTUAL PROPERTY CONTAINED WITHIN. REPRODUCTION AND USE OF THESE DESIGNS FOR ANY OTHER PURPOSE IS FORBIDDEN. SCALES ARE PROVIDED FOR REFERENCE ONLY. FOR PRODUCT INFORMATION AND TECHNICAL SUPPORT, PLEASE CONTACT VIVA RAILINGS.
OPTIONS
CIRCA RAILING SYSTEM 3
2"x1"
Ø1-1/2"
TOP RAIL

Wire Mesh Infill

CIRCA RAILING SYSTEM

VIVA RAILINGS IS NOT RESPONSIBLE FOR THE STRUCTURAL INTEGRITY OF ANY BUILDING SYSTEMS OR OTHER MATERIALS NOT FURNISHED BY VIVA RAILINGS. VIVA RAILINGS HAS NO WAY OF KNOWING AND SPECIFICALLY DISCLAIMS WHETHER OR NOT THE BUILDING SYSTEMS TO WHICH VIVA RAILINGS' PRODUCTS ARE TO BE ATTACHED ARE STRUCTURALLY SOUND OR DESIGNED TO PROPERLY SUPPORT VIVA RAILINGS'S MATERIALS. ANY SUCH DESIGN RESPONSIBILITY BELONGS TO OTHERS FOR WHOM VIVA RAILINGS IS NOT RESPONSIBLE. THESE DRAWINGS ARE INTENDED FOR THE SOLE USE OF VIVA RAILINGS' CUSTOMER AND THEIR AGENTS FOR THE INSTALLATION OF PRODUCTS FURNISHED BY VIVA RAILINGS. VIVA RAILINGS REMAINS THE SOLE OWNER OF ALL DESIGNS AND INTELLECTUAL PROPERTY CONTAINED WITHIN. REPRODUCTION AND USE OF THESE DESIGNS FOR ANY OTHER PURPOSE IS FORBIDDEN. SCALES ARE PROVIDED FOR REFERENCE ONLY.

6
TOP
4'-6" MAX 4'-6" MAX 1'-0" 1'-0"
HAND RAIL WIRE MESH
RAIL
STRINGER
2" NOM. 3" NOM. WM-10 1 5 16 " 7 16 " WM-15 WM-13 WM-17
WM-21 9 16 " TYP. 1" TYP. V V A TM I
WIRE MESH
CIRCA POST TOP RAIL HAND RAIL
WM-19 WM-20
31 2 " NOM. GAP WM-11 WM-12 WM-14 7 16 11 16 1 2 13116 33 4 " 7 16 21 8 " 7 8 1 7 8 " 1 7 8 " 5 8 " 9 16 " 1 1 16 " 13 16 " 15 16 " 3 8 "
FOR PRODUCT INFORMATION AND TECHNICAL SUPPORT, PLEASE CONTACT VIVA RAILINGS.
LEVEL 1 0'-0" FINISH FLOOR 3'-0" 3'-6"
RAIL OPTIONS Ø2" TUBE Ø1-1/2" TUBE 2"x1" TUBE
iRAIL VIVA RAILINGS, LLC 151 W. VISTA RIDGE MALL Dr. LEWISVILLE, TX 75067 P: 972-353-8482 F: 972-353-0013 e: info@vivarailings.com www.vivarailings.com AVAILABLE WIREMESH TYPES: SPIDER CLAMP Page 2.3 OF 5 12/4/2023 info@vivarailings.com 151 W. Vista Ridge Mall Dr. Lewisville, TX 75067 972-353-8482 vivarailings.com VIVA RAILINGS IS NOT RESPONSIBLE FOR THE STRUCTURAL INTEGRITY OF ANY BUILDING SYSTEMS OR OTHER MATERIALS NOT FURNISHED BY VIVA RAILINGS. VIVA RAILINGS HAS NO WAY OF KNOWING AND SPECIFICALLY DISCLAIMS WHETHER OR NOT THE BUILDING SYSTEMS TO WHICH VIVA RAILINGS’ PRODUCTS ARE TO BE ATTACHED ARE STRUCTURALLY SOUND OR DESIGNED TO PROPERLY SUPPORT VIVA RAILINGS’S MATERIALS. ANY SUCH DESIGN RESPONSIBILITY BELONGS TO OTHERS FOR WHOM VIVA RAILINGS IS NOT RESPONSIBLE. THESE DRAWINGS ARE INTENDED FOR THE SOLE USE OF VIVA RAILINGS’ CUSTOMER AND THEIR AGENTS FOR THE INSTALLATION OF PRODUCTS FURNISHED BY VIVA RAILINGS. VIVA RAILINGS REMAINS THE SOLE OWNER OF ALL DESIGNS AND INTELLECTUAL PROPERTY CONTAINED WITHIN. REPRODUCTION AND USE OF THESE DESIGNS FOR ANY OTHER PURPOSE IS FORBIDDEN. SCALES ARE PROVIDED FOR REFERENCE ONLY. FOR PRODUCT INFORMATION AND TECHNICAL SUPPORT, PLEASE CONTACT VIVA RAILINGS. WIRE MESH INFILL CIRCA RAILING SYSTEM AVAILABLE WIRE MESH TYPES TOP RAIL OPTIONS
R4"
TOP
Ø1-1/2"

CIRCA RAILING SYSTEM

TOP RAIL

HAND RAIL

TOP RAIL 5'-0" MAX 5'-0" MAX

PICKET

HAND RAIL

Ø2" TUBE

Ø1-1/2" TUBE

3'-0" 3'-6"

R4"

LEVEL 1 0'-0"

CIRCA POST

PICKET

FINISH FLOOR

STRINGER

2"x1" TUBE

Ø1-1/2" iRAIL

TOP RAIL OPTIONS

VIVA RAILINGS IS NOT RESPONSIBLE FOR THE STRUCTURAL INTEGRITY OF ANY BUILDING SYSTEMS OR OTHER MATERIALS NOT FURNISHED BY VIVA RAILINGS. VIVA RAILINGS HAS NO WAY OF KNOWING AND SPECIFICALLY DISCLAIMS WHETHER OR NOT THE BUILDING SYSTEMS TO WHICH VIVA RAILINGS' PRODUCTS ARE TO BE ATTACHED ARE STRUCTURALLY SOUND OR DESIGNED TO PROPERLY SUPPORT VIVA RAILINGS'S MATERIALS. ANY SUCH DESIGN RESPONSIBILITY BELONGS TO OTHERS FOR WHOM VIVA RAILINGS IS NOT RESPONSIBLE. THESE DRAWINGS ARE INTENDED FOR THE SOLE USE OF VIVA RAILINGS' CUSTOMER AND THEIR AGENTS FOR THE INSTALLATION OF PRODUCTS FURNISHED BY VIVA RAILINGS. VIVA RAILINGS REMAINS THE SOLE OWNER OF ALL DESIGNS AND INTELLECTUAL PROPERTY CONTAINED WITHIN. REPRODUCTION AND USE OF THESE DESIGNS FOR ANY OTHER PURPOSE IS FORBIDDEN. SCALES ARE PROVIDED FOR REFERENCE ONLY. FOR PRODUCT INFORMATION AND TECHNICAL SUPPORT, PLEASE CONTACT VIVA RAILINGS.

7
1'-0" 1'-0" Picket Infill
2" NOM. 3" NOM.
2
V A
Ø1" TUBE Ø1
" TUBE 4" MAX.
151 W. VISTA RIDGE MALL Dr. LEWISVILLE, TX 75067 P: 972-353-8482 F: 972-353-0013 e: info@vivarailings.com www.vivarailings.com Page 2.4 OF 5 12/4/2023 info@vivarailings.com 151 W. Vista Ridge Mall Dr. Lewisville, TX 75067 972-353-8482 vivarailings.com VIVA RAILINGS IS NOT RESPONSIBLE FOR THE STRUCTURAL INTEGRITY OF ANY BUILDING SYSTEMS OR OTHER MATERIALS NOT FURNISHED BY VIVA RAILINGS. VIVA RAILINGS HAS NO WAY OF KNOWING AND SPECIFICALLY DISCLAIMS WHETHER OR NOT THE BUILDING SYSTEMS TO WHICH VIVA RAILINGS’ PRODUCTS ARE TO BE ATTACHED ARE STRUCTURALLY SOUND OR DESIGNED TO PROPERLY SUPPORT VIVA RAILINGS’S MATERIALS. ANY SUCH DESIGN RESPONSIBILITY BELONGS TO OTHERS FOR WHOM VIVA RAILINGS IS NOT RESPONSIBLE. THESE DRAWINGS ARE INTENDED FOR THE SOLE USE OF VIVA RAILINGS’ CUSTOMER AND THEIR AGENTS FOR THE INSTALLATION OF PRODUCTS FURNISHED BY VIVA RAILINGS. VIVA RAILINGS REMAINS THE SOLE OWNER OF ALL DESIGNS AND INTELLECTUAL PROPERTY CONTAINED WITHIN. REPRODUCTION AND USE OF THESE DESIGNS FOR ANY OTHER PURPOSE IS FORBIDDEN. SCALES ARE PROVIDED FOR REFERENCE ONLY. FOR PRODUCT INFORMATION AND TECHNICAL SUPPORT, PLEASE CONTACT VIVA RAILINGS. CIRCA RAILING SYSTEM PICKET PANEL INFILL
RAIL OPTIONS
TOP

CIRCA RAILING SYSTEM

Multiline Infill

TOP RAIL

HAND RAIL

RAIL

MULTILINE

HAND RAIL

CIRCA POST

MULTILINE

FINISH FLOOR

STRINGER

TOP RAIL OPTIONS

TOP RAIL OPTIONS

LEVEL 1 0'-0"

VIVA RAILINGS IS NOT RESPONSIBLE FOR THE STRUCTURAL INTEGRITY OF ANY BUILDING SYSTEMS OR OTHER MATERIALS NOT FURNISHED BY VIVA RAILINGS. VIVA RAILINGS HAS NO WAY OF KNOWING AND SPECIFICALLY DISCLAIMS WHETHER OR NOT THE BUILDING SYSTEMS TO WHICH VIVA RAILINGS' PRODUCTS ARE TO BE ATTACHED ARE STRUCTURALLY SOUND OR DESIGNED TO PROPERLY SUPPORT VIVA RAILINGS'S MATERIALS. ANY SUCH DESIGN RESPONSIBILITY BELONGS TO OTHERS FOR WHOM VIVA RAILINGS IS NOT RESPONSIBLE. THESE DRAWINGS ARE INTENDED FOR THE SOLE USE OF VIVA RAILINGS' CUSTOMER AND THEIR AGENTS FOR THE INSTALLATION OF PRODUCTS FURNISHED BY VIVA RAILINGS. VIVA RAILINGS REMAINS THE SOLE OWNER OF ALL DESIGNS AND INTELLECTUAL PROPERTY CONTAINED WITHIN. REPRODUCTION AND USE OF THESE DESIGNS FOR ANY OTHER PURPOSE IS FORBIDDEN. SCALES ARE PROVIDED FOR REFERENCE ONLY. FOR PRODUCT INFORMATION AND TECHNICAL SUPPORT, PLEASE CONTACT VIVA RAILINGS.

8
MAX 1'-0"
TOP
4'-0" MAX 4'-0"
1'-0"
2"
4" MAX.
1 2 "
4"
V V A TM I
MAX.
Ø
TUBE
MAX.
R4"
3'-0" 3'-6"
Ø2" TUBE Ø1-1/2" TUBE 2"x1" TUBE
VIVA RAILINGS, LLC 151 W. VISTA RIDGE MALL Dr. LEWISVILLE, TX 75067 P: 972-353-8482 F: 972-353-0013 e: info@vivarailings.com www.vivarailings.com Page 2.5 OF 5 12/4/2023 info@vivarailings.com 151 W. Vista Ridge Mall Dr. Lewisville, TX 75067 972-353-8482 vivarailings.com VIVA RAILINGS IS NOT RESPONSIBLE FOR THE STRUCTURAL INTEGRITY OF ANY BUILDING SYSTEMS OR OTHER MATERIALS NOT FURNISHED BY VIVA RAILINGS. VIVA RAILINGS HAS NO WAY OF KNOWING AND SPECIFICALLY DISCLAIMS WHETHER OR NOT THE BUILDING SYSTEMS TO WHICH VIVA RAILINGS’ PRODUCTS ARE TO BE ATTACHED ARE STRUCTURALLY SOUND OR DESIGNED TO PROPERLY SUPPORT VIVA RAILINGS’S MATERIALS. ANY SUCH DESIGN RESPONSIBILITY BELONGS TO OTHERS FOR WHOM VIVA RAILINGS IS NOT RESPONSIBLE. THESE DRAWINGS ARE INTENDED FOR THE SOLE USE OF VIVA RAILINGS’ CUSTOMER AND THEIR AGENTS FOR THE INSTALLATION OF PRODUCTS FURNISHED BY VIVA RAILINGS. VIVA RAILINGS REMAINS THE SOLE OWNER OF ALL DESIGNS AND INTELLECTUAL PROPERTY CONTAINED WITHIN. REPRODUCTION AND USE OF THESE DESIGNS FOR ANY OTHER PURPOSE IS FORBIDDEN. SCALES ARE PROVIDED FOR REFERENCE ONLY. FOR PRODUCT INFORMATION AND TECHNICAL SUPPORT, PLEASE CONTACT VIVA RAILINGS. MULTILINE INFILL CIRCA RAILING SYSTEM
Ø1-1/2" iRAIL

CIRCA RAILING SYSTEM

CONTINUOUS PANEL

CABLENET FRAME

TOP RAIL

HAND RAIL

DIMENSIONS ARE NOMINAL

TOP RAIL

CABLENET PANEL

HAND RAIL

R4"

LEVEL 1 0'-0"

CIRCA POST

CABLENET PANEL

FINISH FLOOR 3'-0"

STRINGER

Ø1/16" [Ø1.5mm]

7x7 CONSTRUCTION CABLE

VIVA RAILINGS IS NOT RESPONSIBLE FOR THE STRUCTURAL INTEGRITY OF ANY BUILDING SYSTEMS OR OTHER MATERIALS NOT FURNISHED BY VIVA RAILINGS. VIVA RAILINGS HAS NO WAY OF KNOWING AND SPECIFICALLY DISCLAIMS WHETHER OR NOT THE BUILDING SYSTEMS TO WHICH VIVA RAILINGS' PRODUCTS ARE TO BE ATTACHED ARE STRUCTURALLY SOUND OR DESIGNED TO PROPERLY SUPPORT VIVA RAILINGS'S MATERIALS. ANY SUCH DESIGN RESPONSIBILITY BELONGS TO OTHERS FOR WHOM VIVA RAILINGS IS NOT RESPONSIBLE. THESE DRAWINGS ARE INTENDED FOR THE SOLE USE OF VIVA RAILINGS' CUSTOMER AND THEIR AGENTS FOR THE INSTALLATION OF PRODUCTS FURNISHED BY VIVA RAILINGS. VIVA RAILINGS REMAINS THE SOLE OWNER OF ALL DESIGNS AND INTELLECTUAL PROPERTY CONTAINED WITHIN. REPRODUCTION AND USE OF THESE DESIGNS FOR ANY OTHER PURPOSE IS FORBIDDEN. SCALES ARE PROVIDED FOR REFERENCE ONLY. FOR PRODUCT INFORMATION AND TECHNICAL SUPPORT, PLEASE CONTACT VIVA RAILINGS.

9 CP06 CP07 CP07
1'-0" 1'-0" CableNet Infill
2"
NOM. 41 8 " V A
NOM. 3"
4 1 4 " NOM. GAP
5'-0" MAX 5'-0" MAX
3 8 60°
2
3'-6"
OPTIONS
iRAIL 1"
TOP RAIL
Ø2" TUBE Ø1-1/2" TUBE 2"x1" TUBE Ø1-1/2"
151 W. VISTA RIDGE MALL Dr. LEWISVILLE, TX 75067 P: 972-353-8482 F: 972-353-0013 e: info@vivarailings.com www.vivarailings.com Page 2.7 OF 5 12/4/2023 info@vivarailings.com 151 W. Vista Ridge Mall Dr. Lewisville, TX 75067 972-353-8482 vivarailings.com VIVA RAILINGS IS NOT RESPONSIBLE FOR THE STRUCTURAL INTEGRITY OF ANY BUILDING SYSTEMS OR OTHER MATERIALS NOT FURNISHED BY VIVA RAILINGS. VIVA RAILINGS HAS NO WAY OF KNOWING AND SPECIFICALLY DISCLAIMS WHETHER OR NOT THE BUILDING SYSTEMS TO WHICH VIVA RAILINGS’ PRODUCTS ARE TO BE ATTACHED ARE STRUCTURALLY SOUND OR DESIGNED TO PROPERLY SUPPORT VIVA RAILINGS’S MATERIALS. ANY SUCH DESIGN RESPONSIBILITY BELONGS TO OTHERS FOR WHOM VIVA RAILINGS IS NOT RESPONSIBLE. THESE DRAWINGS ARE INTENDED FOR THE SOLE USE OF VIVA RAILINGS’ CUSTOMER AND THEIR AGENTS FOR THE INSTALLATION OF PRODUCTS FURNISHED BY VIVA RAILINGS. VIVA RAILINGS REMAINS THE SOLE OWNER OF ALL DESIGNS AND INTELLECTUAL PROPERTY CONTAINED WITHIN. REPRODUCTION AND USE OF THESE DESIGNS FOR ANY OTHER PURPOSE IS FORBIDDEN. SCALES ARE PROVIDED FOR REFERENCE ONLY. FOR PRODUCT INFORMATION AND TECHNICAL SUPPORT, PLEASE CONTACT VIVA RAILINGS. CIRCA RAILING SYSTEM CABLENET INFILL TOP RAIL OPTIONS

CIRCA RAILING SYSTEM

Cable Infill

TOP RAIL

HAND RAIL

Stainless Steel 316 Cable Ø3/16", 1X19 Construction

RAIL

CABLE

HAND RAIL

CIRCA POST

CABLE

FINISH FLOOR 3'-0"

Ø1-1/2" iRAIL

STRINGER

TOP RAIL OPTIONS

VIVA RAILINGS IS NOT RESPONSIBLE FOR THE STRUCTURAL INTEGRITY OF ANY BUILDING SYSTEMS OR OTHER MATERIALS NOT FURNISHED BY VIVA RAILINGS. VIVA RAILINGS HAS NO WAY OF KNOWING AND SPECIFICALLY DISCLAIMS WHETHER OR NOT THE BUILDING SYSTEMS TO WHICH VIVA RAILINGS' PRODUCTS ARE TO BE ATTACHED ARE STRUCTURALLY SOUND OR DESIGNED TO PROPERLY SUPPORT VIVA RAILINGS'S MATERIALS. ANY SUCH DESIGN RESPONSIBILITY BELONGS TO OTHERS FOR WHOM VIVA RAILINGS IS NOT RESPONSIBLE. THESE DRAWINGS ARE INTENDED FOR THE SOLE USE OF VIVA RAILINGS' CUSTOMER AND THEIR AGENTS FOR THE INSTALLATION OF PRODUCTS FURNISHED BY VIVA RAILINGS. VIVA RAILINGS REMAINS THE SOLE OWNER OF ALL DESIGNS AND INTELLECTUAL PROPERTY CONTAINED WITHIN. REPRODUCTION AND USE OF THESE DESIGNS FOR ANY OTHER PURPOSE IS FORBIDDEN. SCALES ARE PROVIDED FOR REFERENCE ONLY. FOR PRODUCT INFORMATION AND TECHNICAL SUPPORT, PLEASE CONTACT VIVA RAILINGS.

10
1'-0" 1'-0"
TOP
4'-0" MAX 4'-0" MAX
3"
4"
V V A TM I
MAX.
MAX.
R4"
0'-0"
LEVEL 1
3'-6"
Ø2" TUBE Ø1-1/2" TUBE 2"x1" TUBE
1 4 " MAX.
3
VIVA RAILINGS, LLC 151 W. VISTA RIDGE MALL Dr. LEWISVILLE, TX 75067 P: 972-353-8482 F: 972-353-0013 e: info@vivarailings.com www.vivarailings.com Page 2.6 OF 5 12/4/2023 info@vivarailings.com 151 W. Vista Ridge Mall Dr. Lewisville, TX 75067 972-353-8482 vivarailings.com VIVA RAILINGS IS NOT RESPONSIBLE FOR THE STRUCTURAL INTEGRITY OF ANY BUILDING SYSTEMS OR OTHER MATERIALS NOT FURNISHED BY VIVA RAILINGS. VIVA RAILINGS HAS NO WAY OF KNOWING AND SPECIFICALLY DISCLAIMS WHETHER OR NOT THE BUILDING SYSTEMS TO WHICH VIVA RAILINGS’ PRODUCTS ARE TO BE ATTACHED ARE STRUCTURALLY SOUND OR DESIGNED TO PROPERLY SUPPORT VIVA RAILINGS’S MATERIALS. ANY SUCH DESIGN RESPONSIBILITY BELONGS TO OTHERS FOR WHOM VIVA RAILINGS IS NOT RESPONSIBLE. THESE DRAWINGS ARE INTENDED FOR THE SOLE USE OF VIVA RAILINGS’ CUSTOMER AND THEIR AGENTS FOR THE INSTALLATION OF PRODUCTS FURNISHED BY VIVA RAILINGS. VIVA RAILINGS REMAINS THE SOLE OWNER OF ALL DESIGNS AND INTELLECTUAL PROPERTY CONTAINED WITHIN. REPRODUCTION AND USE OF THESE DESIGNS FOR ANY OTHER PURPOSE IS FORBIDDEN. SCALES ARE PROVIDED FOR REFERENCE ONLY. FOR PRODUCT INFORMATION AND TECHNICAL SUPPORT, PLEASE CONTACT VIVA RAILINGS. CABLE INFILL CIRCA RAILING SYSTEM
OPTIONS
TOP RAIL

CIRCA RAILING SYSTEM

Laser cut w/ spiders

SPIDER

TOP RAIL

HAND RAIL

5'-0" MAX 1'-0"

5'-0" MAX

TOP RAIL

ALUMINUM PANEL

HAND RAIL

CIRCA POST

LAMINATED GLASS

FINISH FLOOR

STRINGER

TOP RAIL OPTIONS

1'-0"

VIVA RAILINGS IS NOT RESPONSIBLE FOR THE STRUCTURAL INTEGRITY OF ANY BUILDING SYSTEMS OR OTHER MATERIALS NOT FURNISHED BY VIVA RAILINGS. VIVA RAILINGS HAS NO WAY OF KNOWING AND SPECIFICALLY DISCLAIMS WHETHER OR NOT THE BUILDING SYSTEMS TO WHICH VIVA RAILINGS' PRODUCTS ARE TO BE ATTACHED ARE STRUCTURALLY SOUND OR DESIGNED TO PROPERLY SUPPORT VIVA RAILINGS'S MATERIALS. ANY SUCH DESIGN RESPONSIBILITY BELONGS TO OTHERS FOR WHOM VIVA RAILINGS IS NOT RESPONSIBLE. THESE DRAWINGS ARE INTENDED FOR THE SOLE USE OF VIVA RAILINGS' CUSTOMER AND THEIR AGENTS FOR THE INSTALLATION OF PRODUCTS FURNISHED BY VIVA RAILINGS. VIVA RAILINGS REMAINS THE SOLE OWNER OF ALL DESIGNS AND INTELLECTUAL PROPERTY CONTAINED WITHIN. REPRODUCTION AND USE OF THESE DESIGNS FOR ANY OTHER PURPOSE IS FORBIDDEN. SCALES ARE PROVIDED FOR REFERENCE ONLY. FOR PRODUCT INFORMATION AND TECHNICAL SUPPORT, PLEASE CONTACT VIVA RAILINGS.

11
0'-0"
LEVEL 1
3'-0" 3'-6"
2" NOM. 3" NOM.
V V A TM
3 1 2 "
NOM. GAP
R4" Ø2" TUBE Ø1-1/2" TUBE 2"x1" TUBE
VIVA RAILINGS, LLC 151 W. VISTA RIDGE MALL Dr. LEWISVILLE, TX 75067 P: 972-353-8482 F: 972-353-0013 e: info@vivarailings.com www.vivarailings.com Page 2.1B OF 5 12/4/2023 Visit https://vivarailings.com/
Or
info@vivarailings.com 151 W. Vista Ridge Mall Dr. Lewisville, TX 75067 972-353-8482 vivarailings.com VIVA RAILINGS IS NOT RESPONSIBLE FOR THE STRUCTURAL INTEGRITY OF ANY BUILDING SYSTEMS OR OTHER MATERIALS NOT FURNISHED BY VIVA RAILINGS. VIVA RAILINGS HAS NO WAY OF KNOWING AND SPECIFICALLY DISCLAIMS WHETHER OR NOT THE BUILDING SYSTEMS TO WHICH VIVA RAILINGS’ PRODUCTS ARE TO BE ATTACHED ARE STRUCTURALLY SOUND OR DESIGNED TO PROPERLY SUPPORT VIVA RAILINGS’S MATERIALS. ANY SUCH DESIGN RESPONSIBILITY BELONGS TO OTHERS FOR WHOM VIVA RAILINGS IS NOT RESPONSIBLE. THESE DRAWINGS ARE INTENDED FOR THE SOLE USE OF VIVA RAILINGS’ CUSTOMER AND THEIR AGENTS FOR THE INSTALLATION OF PRODUCTS FURNISHED BY VIVA RAILINGS. VIVA RAILINGS REMAINS THE SOLE OWNER OF ALL DESIGNS AND INTELLECTUAL PROPERTY CONTAINED WITHIN. REPRODUCTION AND USE OF THESE DESIGNS FOR ANY OTHER PURPOSE IS FORBIDDEN. SCALES ARE PROVIDED FOR REFERENCE ONLY. FOR PRODUCT INFORMATION AND TECHNICAL SUPPORT, PLEASE CONTACT VIVA RAILINGS. LASER CUT INFILL CIRCA RAILING SYSTEM TOP RAIL OPTIONS
Ø1-1/2" iRAIL
for range of design patterns
provide your custom pattern

CIRCA RAILING SYSTEM

Mounting Condition, Top Mounted Post

Anchored to Concrete ¹ - $ ²

Detail# CA-T01 ³

Embed Plate (By others)

Cored into Concrete - $$

Detail# CA-T02

Welded @ Embed Plate - $

Detail# CA-T04

(1) Min. 4000 PSI concrete, Typ.

(2) $ to $$$: Indicates mounting type comparative cost

(3) Anchoring is not an available option for top mount with cable infill

(4) 6 1 2" Min. for end post with cable infil

Anchored to Concrete Slab on Deck - $$

Detail# CA-T05

VIVA RAILINGS IS NOT RESPONSIBLE FOR THE STRUCTURAL INTEGRITY OF ANY BUILDING SYSTEMS OR OTHER MATERIALS NOT FURNISHED

RAILINGS' PRODUCTS ARE TO BE ATTACHED ARE STRUCTURALLY SOUND OR DESIGNED TO PROPERLY SUPPORT

AND SPECIFICALLY

Welded @ Steel Channel - $

Detail# CA-T03

Anchored to Concrete

Welded to Steel Plate -

Detail# CA-T06

3/8"

WHETHER OR NOT THE BUILDING SYSTEMS TO WHICH

RAILINGS'S MATERIALS. ANY SUCH DESIGN RESPONSIBILITY BELONGS TO OTHERS FOR WHOM VIVA RAILINGS IS NOT RESPONSIBLE. THESE DRAWINGS ARE INTENDED FOR THE SOLE USE OF VIVA RAILINGS' CUSTOMER AND THEIR AGENTS FOR THE INSTALLATION OF PRODUCTS FURNISHED BY VIVA RAILINGS. VIVA RAILINGS REMAINS THE SOLE OWNER OF ALL DESIGNS AND INTELLECTUAL PROPERTY CONTAINED WITHIN. REPRODUCTION AND USE

12
6" MIN.
3" MIN. 5" MIN. 6" MIN. 5" ⁴ MIN. 5" MIN. 5" MIN.
61 2 " MIN. 3" MIN. V V A TM I
OF THESE DESIGNS FOR ANY OTHER PURPOSE IS FORBIDDEN. SCALES ARE PROVIDED FOR REFERENCE ONLY. FOR PRODUCT INFORMATION AND TECHNICAL SUPPORT, PLEASE CONTACT VIVA RAILINGS.
BY VIVA RAILINGS. VIVA RAILINGS HAS NO WAY OF KNOWING
DISCLAIMS
VIVA
VIVA
$
BENT PLATE
OTHERS) 25 8 " 6" MIN. VIVA RAILINGS, LLC 151 W. VISTA RIDGE MALL Dr. LEWISVILLE, TX 75067 P: 972-353-8482 F: 972-353-0013 e: info@vivarailings.com www.vivarailings.com Page 3.1 OF 5 12/4/2023 info@vivarailings.com 151 W. Vista Ridge Mall Dr. Lewisville, TX 75067 972-353-8482 vivarailings.com VIVA RAILINGS IS NOT RESPONSIBLE FOR THE STRUCTURAL INTEGRITY OF ANY BUILDING SYSTEMS OR OTHER MATERIALS NOT FURNISHED BY VIVA RAILINGS. VIVA RAILINGS HAS NO WAY OF KNOWING AND SPECIFICALLY DISCLAIMS WHETHER OR NOT THE BUILDING SYSTEMS TO WHICH VIVA RAILINGS’ PRODUCTS ARE TO BE ATTACHED ARE STRUCTURALLY SOUND OR DESIGNED TO PROPERLY SUPPORT VIVA RAILINGS’S MATERIALS. ANY SUCH DESIGN RESPONSIBILITY BELONGS TO OTHERS FOR WHOM VIVA RAILINGS IS NOT RESPONSIBLE. THESE DRAWINGS ARE INTENDED FOR THE SOLE USE OF VIVA RAILINGS’ CUSTOMER AND THEIR AGENTS FOR THE INSTALLATION OF PRODUCTS FURNISHED BY VIVA RAILINGS. VIVA RAILINGS REMAINS THE SOLE OWNER OF ALL DESIGNS AND INTELLECTUAL PROPERTY CONTAINED WITHIN. REPRODUCTION AND USE OF THESE DESIGNS FOR ANY OTHER PURPOSE IS FORBIDDEN. SCALES ARE PROVIDED FOR REFERENCE ONLY. FOR PRODUCT INFORMATION AND TECHNICAL SUPPORT, PLEASE CONTACT VIVA RAILINGS. CIRCA RAILING SYSTEM MOUNTING CONDITION, TOP MOUNTED POST
(BY

CIRCA RAILING SYSTEM

Mounting Condition, Fascia Mounted Post

Embed Plate (By others)

6" MIN.

Anchored to Concrete ¹ - $$$

Detail# CA-F01 ²

Welded @ Embed Plate - $$

Detail# CA-F02

Welded @ Steel Channel - $$

Detail# CA-F03

Welded @ Steel Tube - $$

Detail# CA-F04

(1) Min. 4000 PSI concrete, Typ.

(2) Anchoring is not a recommended option for cable infill

3/8"

STUD or

3" MIN.

3" MIN.

Welded @ Pour Stop - $$

Detail# CA-F05

VIVA RAILINGS IS NOT RESPONSIBLE FOR THE STRUCTURAL INTEGRITY OF ANY BUILDING SYSTEMS OR OTHER MATERIALS NOT FURNISHED BY VIVA RAILINGS. VIVA RAILINGS HAS NO WAY OF KNOWING AND SPECIFICALLY DISCLAIMS WHETHER OR NOT THE BUILDING SYSTEMS TO WHICH VIVA RAILINGS' PRODUCTS ARE TO BE ATTACHED ARE STRUCTURALLY SOUND OR DESIGNED TO PROPERLY SUPPORT VIVA RAILINGS'S MATERIALS. ANY SUCH DESIGN RESPONSIBILITY BELONGS TO OTHERS FOR WHOM VIVA RAILINGS IS NOT RESPONSIBLE.

THESE DRAWINGS ARE INTENDED FOR THE SOLE USE OF VIVA RAILINGS' CUSTOMER AND THEIR AGENTS FOR THE INSTALLATION OF PRODUCTS FURNISHED BY VIVA RAILINGS. VIVA RAILINGS REMAINS THE SOLE OWNER OF ALL DESIGNS AND INTELLECTUAL PROPERTY CONTAINED WITHIN. REPRODUCTION AND USE OF THESE DESIGNS FOR ANY OTHER PURPOSE IS FORBIDDEN. SCALES ARE PROVIDED FOR REFERENCE ONLY. FOR PRODUCT INFORMATION AND TECHNICAL SUPPORT, PLEASE CONTACT VIVA RAILINGS.

13 6" 6" 6"
6" MIN. 6" V V A TM
6" 6"
DEFORMED REBAR (BY OTHERS)
THICK POUR STOP (BY OTHERS) VIVA RAILINGS, LLC 151 W. VISTA RIDGE MALL Dr. LEWISVILLE, TX 75067 P: 972-353-8482 F: 972-353-0013 e: info@vivarailings.com www.vivarailings.com Page 3.2 OF 5 12/4/2023 info@vivarailings.com 151 W. Vista Ridge Mall Dr. Lewisville, TX 75067 972-353-8482 vivarailings.com VIVA RAILINGS IS NOT RESPONSIBLE FOR THE STRUCTURAL INTEGRITY OF ANY BUILDING SYSTEMS OR OTHER MATERIALS NOT FURNISHED BY VIVA RAILINGS. VIVA RAILINGS HAS NO WAY OF KNOWING AND SPECIFICALLY DISCLAIMS WHETHER OR NOT THE BUILDING SYSTEMS TO WHICH VIVA RAILINGS’ PRODUCTS ARE TO BE ATTACHED ARE STRUCTURALLY SOUND OR DESIGNED TO PROPERLY SUPPORT VIVA RAILINGS’S MATERIALS. ANY SUCH DESIGN RESPONSIBILITY BELONGS TO OTHERS FOR WHOM VIVA RAILINGS IS NOT RESPONSIBLE. THESE DRAWINGS ARE INTENDED FOR THE SOLE USE OF VIVA RAILINGS’ CUSTOMER AND THEIR AGENTS FOR THE INSTALLATION OF PRODUCTS FURNISHED BY VIVA RAILINGS. VIVA RAILINGS REMAINS THE SOLE OWNER OF ALL DESIGNS AND INTELLECTUAL PROPERTY CONTAINED WITHIN. REPRODUCTION AND USE OF THESE DESIGNS FOR ANY OTHER PURPOSE IS FORBIDDEN. SCALES ARE PROVIDED FOR REFERENCE ONLY. FOR PRODUCT INFORMATION AND TECHNICAL SUPPORT, PLEASE CONTACT VIVA RAILINGS. CIRCA RAILING SYSTEM MOUNTING CONDITION, FASCIA MOUNTED POST
14 V V A TM I CIRCA RAILING SYSTEM Illuminated Railing Ø11 2 " 36 " TO FF TOP RAIL ILLUMINATED HANDRAIL See Viva iRail Railing System for more info 215 16 " 4 2 " TO FF Illuminated Hand rail Option Illuminated Top rail Option iRAIL POD ORIENTATION OPTIONS 18" 24" OR 36" iRAIL POD SPACING OPTIONS POD iRAIL Linear 30° ASYM. LINEAR SYM. LINEAR iRAIL LINEAR ORIENTATION OPTIONS 22° ASYM. POD SYM. POD Ø11 2 " VIVA RAILINGS, LLC 151 W. VISTA RIDGE MALL Dr. LEWISVILLE, TX 75067 P: 972-353-8482 F: 972-353-0013 e: info@vivarailings.com www.vivarailings.com Page 4 OF 5 12/4/2023 info@vivarailings.com 151 W. Vista Ridge Mall Dr. Lewisville, TX 75067 972-353-8482 vivarailings.com CIRCA RAILING SYSTEM iRAIL LIGHTED RAILING SYSTEM ILLUMINATED RAILING

#8 Mirror Finish comes at an additional cost to our #6 Finish.

ECM finish is not available for U-cap, top rail or hand rail.

Available in Satin Black, Brass, Gold & Copper.

COAT

Available in Standard and Premium Colors

15 info@vivarailings.com 151 W. Vista Ridge Mall Dr. Lewisville, TX 75067 972-353-8482 vivarailings.com
#6 SATIN - #8 MIRROR ECM POWDER
CIRCA
PERF RAILING SYSTEM FINISHING OPTIONS
16 CIRCA PERF METAL RAILING SYSTEM DOBIE ISD STRICKLAND MIDDLE SCHOOL info@vivarailings.com 151 W. Vista Ridge Mall Dr. Lewisville, TX 75067 972-353-8482 vivarailings.com General Contractor: Balfour Beatty Contractors Architect: VLK Architects DOBIE ISD STRICKLAND M.S. - DENTON, TX
17 info@vivarailings.com 151 W. Vista Ridge Mall Dr. Lewisville, TX 75067 972-353-8482 vivarailings.com CIRCA PERF METAL RAILING SYSTEM DOBIE ISD STRICKLAND MIDDLE SCHOOL General Contractor: Balfour Beatty Contractors Architect: VLK Architects DOBIE ISD STRICKLAND M.S. - DENTON, TX
18 CIRCA PERF METAL RAILING SYSTEM DOBIE ISD 9TH GRADE CENTER info@vivarailings.com 151 W. Vista Ridge Mall Dr. Lewisville, TX 75067 972-353-8482 vivarailings.com General Contractor: Drymalla Construction Co. DOBIE ISD 9TH GRADE CENTER - HOUSTON, TX Architect: IBI Group Architect
19 CIRCA PERF METAL RAILING SYSTEM DOBIE ISD 9TH GRADE CENTER info@vivarailings.com 151 W. Vista Ridge Mall Dr. Lewisville, TX 75067 972-353-8482 vivarailings.com General Contractor: Drymalla Construction Co. Architect: IBI Group Architect DOBIE ISD 9TH GRADE CENTER - HOUSTON, TX
151 W. Vista Ridge Mall Dr. Lewisville, TX 75067 (Dallas/Fort Worth Metroplex) PH: 972.353.8482 | info@vivarailings.com vivarailings.com NORTH AMERICA OPERATIONS Dallas/Fort Worth, TX San Diego, CA Atlanta, GA Orlando, FL New York, NY Washington DC Regional Locations Version:120423 Kansas City, KS ICC-ES 4405 Certified SHOE™ Structural Glass Railing System The American Institute of Architects The California Contractors State License Board Certified Inc. Magazine 500 | 5000 VIVA RAILINGS, LLC. Among The Fastest Growing US Companies Eight Years in a Row 2012-2019 Inc. Magazine 500 | 5000 VIVA RAILINGS, LLC. Among The Fastest Growing Texas Companies #211 LEED Material & Resources Credits 4.1 and 4.2

Turn static files into dynamic content formats.

Create a flipbook
Issuu converts static files into: digital portfolios, online yearbooks, online catalogs, digital photo albums and more. Sign up and create your flipbook.