CIRCA GLASS RAILING SYSTEM PRODUCT DATA ™

CIRCA - AVAILABLE INFILLS Glass Perforated Metal Wire Mesh Picket Panel CableNet Multiline Cable Lasercut Panels

151 W. Vista Ridge Mall Dr. Lewisville, TX 75067

972-353-8482

info@vivarailings.com

vivarailings.com


CIRCA GLASS RAILING SYSTEM ™

CIRCA - AVAILABLE INFILLS

Our CIRCA Stainless Steel Railing System provides a simple yet timeless look. The system consists of round tubular posts and the railing in-fill between the posts is mounted via fixed point holders.

Glass Perforated Metal Wire Mesh Picket Panel

CIRCA GLASS SPIDER-11/11/22

CableNet Multiline Lasercut Panels

Other mounting options available.

2

151 W. Vista Ridge Mall Dr. Lewisville, TX 75067

972-353-8482

info@vivarailings.com

vivarailings.com


CIRCA GLASS & METAL SYSTEM - TECHNICAL DATA ™

MATERIAL

FINISH

#6 Satin, #8 Mirror

POST

ECM

Ø2” @ 5’-0” max. O.C. 4’-6” max. for perforated and wire mesh infill. 4’-0” max. for Multiline and cable infill.

Powder Coat

Fascia, Top or Core mount.

Stainless Steel (304 or 316)

Stainless Steel (201)

SIZE/SPACING

Min. 3/8” laminated glass with PVB or SGP interlayer ¹ Glass standard thickness: 3/8”, 1/2”, 5/8”, 3/4” Glass

Clear, Tinted or Frit Interlayer standard thickness: SGP: 0.035” , 0.06” PVB: 0.035”

Perforated Metal

1” wide frame

Wire Mesh Picket Panel

INFILL OPTIONS

#6 Satin

Ø1/2” picket

Multiline

Ø1/2” multiline

Cable

Ø3/16” cable

CableNet

Ø1” Wide frame, Ø1/16” (1.5mm) cable mesh Powder Coat - Super Polyester (AAMA 2604) - $ 4

Laser Cut

1/4” thick aluminum panel. Powder Coat - PVDF (AAMA 2605) - $$ 4

TOP RAIL/HAND RAIL

Stainless Steel Tube

#6 Satin, Powder Coat

Ø1-1/2” or Ø2” for Hand Rail Ø1-1/2”, Ø2” or 2”x1” Rectangular tube for Top Rail

1. IBC 2015 & newer requires railing glass to be laminated. VIVA recommends SGP for exterior applications.

Stainless Steel Tube with LED ²

#6 Satin

Ø1-1/2” with LED LINEAR, Ø1-1/2” or Ø2” with LED POD

2. All LED LINEAR products are ETL certified; ETL mark is proof of product compliance to North American safety standard.

Wood (Red Oak, Cherry or Maple) ³

Ø2” Unstained

Wood (Red Oak, Cherry or Maple) with LED

3. Other species available upon request.

Ø2” with LED LINEAR

4. $ to $$$: Indicates finish type comparative cost.

151 W. Vista Ridge Mall Dr. Lewisville, TX 75067

972-353-8482

info@vivarailings.com

vivarailings.com

3


CIRCA RAILING SYSTEM

151 W. VISTA RIDGE MALL Dr. LEWISVILLE, TX 75067 P: 972-353-8482 F: 972-353-0013 e: info@vivarailings.com www.vivarailings.com

CIRCA RAILING SYSTEM Glass Infill GLASS INFILL

Page 2.1 OF 5

AVAILABLE GLASS TYPES AVAILABLE GLASS TYPES:

SPIDER

Ceramic Frit

Colored Laminate (PVB only)

Bent

Tinted

Satin Etched

CLAMP Clear Monolithic

5'-0" MAX

Clear Laminated (PVB or SGP)

LAMINATED GLASS

5'-0" MAX

TOP RAIL

HAND RAIL

3" NOM.

TOP RAIL

HAND RAIL

Ø1-1/2" TUBE

3'-0"

1" 32 NOM. GAP

2"x1" TUBE

2" NOM.

R4"

Ø2" TUBE

3'-6"

I V A

FINISH FLOOR

Ø1-1/2" iRAIL

1'-0"

CIRCA POST

STRINGER

LAMINATED GLASS

TOPTOP RAILRAIL OPTIONS OPTIONS

LEVEL 1 0'-0"

1'-0" VIVA RAILINGS IS NOT RESPONSIBLE FOR THE STRUCTURAL INTEGRITY OF ANY BUILDING SYSTEMS OR OTHER MATERIALS NOT FURNISHED BY VIVA RAILINGS. VIVA RAILINGS HAS NO WAY OF KNOWING AND SPECIFICALLY DISCLAIMS WHETHER OR NOT THE BUILDING SYSTEMS TO WHICH VIVA RAILINGS' PRODUCTS ARE TO BE ATTACHED ARE STRUCTURALLY SOUND OR DESIGNED TO PROPERLY SUPPORT VIVA RAILINGS'S MATERIALS. ANY SUCH DESIGN RESPONSIBILITY BELONGS TO OTHERS FOR WHOM VIVA RAILINGS IS NOT RESPONSIBLE. ARE FOR INTENDED FOR INTEGRITY THE SOLE USE OF VIVA RAILINGS' THEIR AGENTS FOR THE INSTALLATION OF PRODUCTS FURNISHED BY VIVAORRAILINGS. VIVA RAILINGS REMAINS THEPRODUCTS SOLE OWNER ALL DESIGNS AND INTELLECTUAL CONTAINED WITHIN. VIVATHESE RAILINGSDRAWINGS IS NOT RESPONSIBLE THE STRUCTURAL OF ANY BUILDING SYSTEMS OR OTHERCUSTOMER MATERIALS NOT AND FURNISHED BY VIVA RAILINGS. VIVA RAILINGS HAS NO WAY OF KNOWING AND SPECIFICALLY DISCLAIMS WHETHER NOT THE BUILDING SYSTEMS TO WHICH VIVA RAILINGS’ ARE TO BEOF ATTACHED ARE STRUCTURALLY SOUND OR DESIGNEDPROPERTY TO PROPERLY SUPPORT VIVAREPRODUCTION RAILINGS’S MATERIALS.AND ANY SUCH RESPONSIBILITY BELONGS TOANY OTHERS FOR WHOM VIVA RAILINGS IS NOT RESPONSIBLE. THESE DRAWINGS ARE INTENDEDFOR FOR THE SOLE USE OF VIVA RAILINGS’ CUSTOMER AND THEIR AGENTS FOR THEAND INSTALLATION OF PRODUCTS FURNISHED BY VIVA RAILINGS. VIVA RAILINGS REMAINS THE SOLE OWNER OF ALL DESIGNS AND INTELLECTUAL PROPERTY USEDESIGN OF THESE DESIGNS FOR OTHER PURPOSE IS FORBIDDEN. SCALES ARE PROVIDED REFERENCE ONLY. FOR PRODUCT INFORMATION TECHNICAL SUPPORT, PLEASE CONTACT VIVA RAILINGS. CONTAINED WITHIN. REPRODUCTION AND USE OF THESE DESIGNS FOR ANY OTHER PURPOSE IS FORBIDDEN. SCALES ARE PROVIDED FOR REFERENCE ONLY. FOR PRODUCT INFORMATION AND TECHNICAL SUPPORT, PLEASE CONTACT VIVA RAILINGS.

4

151 W. Vista Ridge Mall Dr. Lewisville, TX 75067

972-353-8482

info@vivarailings.com

vivarailings.com


V I V A

TM

VIVA RAILINGS, LLC

CIRCA RAILING SYSTEM

151 W. VISTA RIDGE MALL Dr. LEWISVILLE, TX 75067

CIRCA RAILING SYSTEM PERFORATED METAL INFILL Perforated Metal Infill P: 972-353-8482 F: 972-353-0013 e: info@vivarailings.com www.vivarailings.com

Page 2.2 OF 5

1"

9 16"

AVAILABLE AVAILABLE PERFORATEDTYPES TYPES: PERFORATED

1 16" (14 GA)

Ø41"

Ø3 8"

9 16"

7" 8

CLAMP 11 16"

3 5 8" 8"

1" Ø2

PMRO-1217

4'-6" MAX

5 16"

SPIDER

SECTION VIEW

PMRO-1014

1 8"

PMRO-0610

1" 116

3 8"

PMSQ-1013

3" 14

PMSL-0325

4'-6" MAX

PERFORATED METAL

TOP RAIL

2"x1" TUBE

2" NOM.

R4"

Ø2" TUBE

Ø1-1/2" TUBE

3'-0"

1" 32 NOM. GAP

13" 16

PMSL-1122

3'-6"

HAND RAIL

7 16"

HAND RAIL

3" NOM.

TOP RAIL

1"

FINISH FLOOR

Ø1-1/2" iRAIL

1'-0"

CIRCA POST

STRINGER

PERFORATED METAL

TOPTOP RAILRAIL OPTIONS OPTIONS

LEVEL 1 0'-0"

1'-0" VIVA RAILINGS IS NOT RESPONSIBLE FOR THE STRUCTURAL INTEGRITY OF ANY BUILDING SYSTEMS OR OTHER MATERIALS NOT FURNISHED BY VIVA RAILINGS. VIVA RAILINGS HAS NO WAY OF KNOWING AND SPECIFICALLY DISCLAIMS WHETHER OR NOT THE BUILDING SYSTEMS TO WHICH VIVA RAILINGS’ PRODUCTS ARE TO BE ATTACHED ARE STRUCTURALLY SOUND OR DESIGNED TO PROPERLY SUPPORT RAILINGS IS ANY NOT RESPONSIBLE FOR THE STRUCTURAL OF ANY SYSTEMS OR OTHER MATERIALS NOT VIVA RAILINGS. VIVA RAILINGS HAS NO WAY OF KNOWING AND SPECIFICALLY DISCLAIMS WHETHER ORDESIGNS NOT THE BUILDING PROPERTY SYSTEMS TO WHICH VIVA VIVAVIVA RAILINGS’S MATERIALS. SUCH DESIGN RESPONSIBILITY BELONGS TO OTHERS FOR INTEGRITY WHOM VIVA RAILINGS IS NOTBUILDING RESPONSIBLE. THESE DRAWINGS ARE INTENDED FOR THE SOLE USEFURNISHED OF VIVA RAILINGS’BY CUSTOMER AND THEIR AGENTS FOR THE INSTALLATION OF PRODUCTS FURNISHED BY VIVA RAILINGS. VIVA RAILINGS REMAINS THE SOLE OWNER OF ALL AND INTELLECTUAL RAILINGS' TOOF BETHESE ATTACHED ARE SOUNDSCALES OR DESIGNED SUPPORT VIVA RAILINGS'S MATERIALS. ANY SUCH DESIGN RESPONSIBILITY BELONGS TO OTHERS FOR WHOM VIVA RAILINGS IS NOT RESPONSIBLE. CONTAINED WITHIN.PRODUCTS REPRODUCTIONARE AND USE DESIGNS FOR ANYSTRUCTURALLY OTHER PURPOSE IS FORBIDDEN. ARE PROVIDEDTO FORPROPERLY REFERENCE ONLY. FOR PRODUCT INFORMATION AND TECHNICAL SUPPORT, PLEASE CONTACT VIVA RAILINGS.

THESE DRAWINGS ARE INTENDED FOR THE SOLE USE OF VIVA RAILINGS' CUSTOMER AND THEIR AGENTS FOR THE INSTALLATION OF PRODUCTS FURNISHED BY VIVA RAILINGS. VIVA RAILINGS REMAINS THE SOLE OWNER OF ALL DESIGNS AND INTELLECTUAL PROPERTY CONTAINED WITHIN. REPRODUCTION AND USE OF THESE DESIGNS FOR ANY OTHER PURPOSE IS FORBIDDEN. SCALES ARE PROVIDED FOR REFERENCE ONLY. FOR PRODUCT INFORMATION AND TECHNICAL SUPPORT, PLEASE CONTACT VIVA RAILINGS.

151 W. Vista Ridge Mall Dr. Lewisville, TX 75067

972-353-8482

info@vivarailings.com

vivarailings.com

5


VIVA RAILINGS, LLC

CIRCA RAILING SYSTEM

151 W. VISTA RIDGE MALL Dr. LEWISVILLE, TX 75067

1 2" 9 16" TYP.

1" 28

3" 34

17 8"

13" 116

5" 116

7 16"

7 16"

AVAILABLE AVAILABLE WIRE MESH TYPES WIREMESH TYPES:

Page 2.3 OF 5

7" 8

CIRCA RAILING SYSTEM WIRE Wire MESH INFILL Mesh Infill

P: 972-353-8482 F: 972-353-0013 e: info@vivarailings.com www.vivarailings.com

1" TYP.

V I V A

TM

WM-10

WM-13

WM-12

WM-14

SPIDER

15" 16 3" 8

1" 116 9 16"

13" 16

17 8" 5" 8

11 16"

7 16"

WM-11

CLAMP WM-15

4'-6" MAX

WM-19

WM-17

WM-20

4'-6" MAX

WIRE MESH

TOP RAIL

3'-0"

1" 32 NOM. GAP

Ø1-1/2" TUBE

3'-6"

HAND RAIL

2"x1" TUBE

2" NOM.

R4"

Ø2" TUBE

HAND RAIL

3" NOM.

TOP RAIL

WM-21

FINISH FLOOR

Ø1-1/2" iRAIL

1'-0"

CIRCA POST

STRINGER

WIRE MESH

TOPTOP RAILRAIL OPTIONS OPTIONS

LEVEL 1 0'-0"

1'-0" VIVA RAILINGS IS NOT RESPONSIBLE FOR THE STRUCTURAL INTEGRITY OF ANY BUILDING SYSTEMS OR OTHER MATERIALS NOT FURNISHED BY VIVA RAILINGS. VIVA RAILINGS HAS NO WAY OF KNOWING AND SPECIFICALLY DISCLAIMS WHETHER OR NOT THE BUILDING SYSTEMS TO WHICH VIVA VIVA RAILINGS IS NOT RESPONSIBLE FOR THE STRUCTURAL INTEGRITY OF ANY BUILDING SYSTEMS OR OTHER MATERIALS NOT FURNISHED BY VIVA RAILINGS. VIVA RAILINGS HAS NO WAY OF KNOWING AND SPECIFICALLY DISCLAIMS WHETHER OR NOT THE BUILDING SYSTEMS TO WHICH VIVA RAILINGS’ PRODUCTS ARE TO BE ATTACHED ARE STRUCTURALLY SOUND OR DESIGNED TO PROPERLY SUPPORT RAILINGS' PRODUCTS ARE TO BE ATTACHED ARE STRUCTURALLY SOUND OR DESIGNED TO PROPERLY SUPPORT VIVA RAILINGS'S MATERIALS. ANY SUCH DESIGN RESPONSIBILITY BELONGS TO OTHERS FOR WHOM VIVA RAILINGS IS NOT RESPONSIBLE. VIVA RAILINGS’S MATERIALS. ANY SUCH DESIGN RESPONSIBILITY BELONGS TO OTHERS FOR WHOM VIVA RAILINGS IS NOT RESPONSIBLE. THESE DRAWINGS ARE INTENDED FOR THE SOLE USE OF VIVA RAILINGS’ CUSTOMER AND THEIR AGENTS FOR THE INSTALLATION OF PRODUCTS FURNISHED BY VIVA RAILINGS. VIVA RAILINGS REMAINS THE SOLE OWNER OF ALL DESIGNS AND INTELLECTUAL PROPERTY THESE DRAWINGS ARE INTENDED FOR THE SOLE USE VIVA RAILINGS' CUSTOMER THEIR THEPRODUCT INSTALLATION FURNISHED BY VIVA VIVA RAILINGS REMAINS THE SOLE OWNER OF ALL DESIGNS AND INTELLECTUAL PROPERTY CONTAINED WITHIN. CONTAINED WITHIN. REPRODUCTION AND USE OF THESE DESIGNS FOR ANY OF OTHER PURPOSE IS FORBIDDEN. SCALES AREAND PROVIDED FORAGENTS REFERENCEFOR ONLY. FOR INFORMATIONOF ANDPRODUCTS TECHNICAL SUPPORT, PLEASE CONTACT VIVA RAILINGS. RAILINGS. REPRODUCTION AND USE OF THESE DESIGNS FOR ANY OTHER PURPOSE IS FORBIDDEN. SCALES ARE PROVIDED FOR REFERENCE ONLY. FOR PRODUCT INFORMATION AND TECHNICAL SUPPORT, PLEASE CONTACT VIVA RAILINGS.

6

151 W. Vista Ridge Mall Dr. Lewisville, TX 75067

972-353-8482

info@vivarailings.com

vivarailings.com


V I V A

CIRCA RAILING SYSTEM

151 W. VISTA RIDGE MALL Dr. LEWISVILLE, TX 75067 P: 972-353-8482 F: 972-353-0013 e: info@vivarailings.com www.vivarailings.com

CIRCA RAILING SYSTEM Infill PICKETPicket PANEL INFILL

Page 2.4 OF 5

4" MAX.

1" Ø2 TUBE

5'-0" MAX

Ø1" TUBE

5'-0" MAX

PICKET

TOP RAIL

HAND RAIL

3" NOM.

TOP RAIL

3'-6"

Ø1-1/2" TUBE

3'-0"

HAND RAIL

2"x1" TUBE

2" NOM.

R4"

Ø2" TUBE

FINISH FLOOR

Ø1-1/2" iRAIL

1'-0"

CIRCA POST

STRINGER

PICKET

RAIL OPTIONS TOPTOP RAIL OPTIONS

LEVEL 1 0'-0"

1'-0" VIVA RAILINGS IS NOT RESPONSIBLE FOR THE STRUCTURAL INTEGRITY OF ANY BUILDING SYSTEMS OR OTHER MATERIALS NOT FURNISHED BY VIVA RAILINGS. VIVA RAILINGS HAS NO WAY OF KNOWING AND SPECIFICALLY DISCLAIMS WHETHER OR NOT THE BUILDING SYSTEMS TO WHICH VIVA RAILINGS' PRODUCTS ARE TO BE ATTACHED ARE STRUCTURALLY SOUND OR DESIGNED TO PROPERLY SUPPORT VIVA RAILINGS'S MATERIALS. ANY SUCH DESIGN RESPONSIBILITY BELONGS TO OTHERS FOR WHOM VIVA RAILINGS IS NOT RESPONSIBLE. VIVATHESE RAILINGSDRAWINGS IS NOT RESPONSIBLE THE STRUCTURAL OF ANY BUILDING SYSTEMS OR OTHERCUSTOMER MATERIALS NOT AND FURNISHED BY VIVA RAILINGS.FOR VIVA RAILINGS HAS NO WAY OF KNOWING AND SPECIFICALLY DISCLAIMS WHETHER NOT THE BUILDING SYSTEMS TO WHICH VIVA RAILINGS’ ARE TO BEOF ATTACHED ARE STRUCTURALLY SOUND OR DESIGNEDPROPERTY TO PROPERLY SUPPORT AREFOR INTENDED FOR INTEGRITY THE SOLE USE OF VIVA RAILINGS' THEIR AGENTS THE INSTALLATION OF PRODUCTS FURNISHED BY VIVAORRAILINGS. VIVA RAILINGS REMAINS THEPRODUCTS SOLE OWNER ALL DESIGNS AND INTELLECTUAL CONTAINED WITHIN. VIVAREPRODUCTION RAILINGS’S MATERIALS.AND ANY SUCH RESPONSIBILITY BELONGS TOANY OTHERS FOR WHOM VIVA RAILINGS NOT RESPONSIBLE. THESE DRAWINGS ARE INTENDEDFOR FOR THE SOLE USE OF VIVA RAILINGS’ CUSTOMER AND THEIR AGENTS FOR THEAND INSTALLATION OF PRODUCTS FURNISHED BY VIVA RAILINGS. VIVA RAILINGS REMAINS THE SOLE OWNER OF ALL DESIGNS AND INTELLECTUAL PROPERTY USEDESIGN OF THESE DESIGNS FOR OTHER PURPOSE IS IS FORBIDDEN. SCALES ARE PROVIDED REFERENCE ONLY. FOR PRODUCT INFORMATION TECHNICAL SUPPORT, PLEASE CONTACT VIVA RAILINGS. CONTAINED WITHIN. REPRODUCTION AND USE OF THESE DESIGNS FOR ANY OTHER PURPOSE IS FORBIDDEN. SCALES ARE PROVIDED FOR REFERENCE ONLY. FOR PRODUCT INFORMATION AND TECHNICAL SUPPORT, PLEASE CONTACT VIVA RAILINGS.

151 W. Vista Ridge Mall Dr. Lewisville, TX 75067

972-353-8482

info@vivarailings.com

vivarailings.com

7


V I V A

TM

VIVA RAILINGS, LLC

CIRCA RAILING SYSTEM

151 W. VISTA RIDGE MALL Dr. LEWISVILLE, TX 75067

CIRCA RAILING SYSTEM MULTILINE MultilineINFILL Infill

Page 2.5 OF 5

1" Ø2 TUBE

4" MAX.

P: 972-353-8482 F: 972-353-0013 e: info@vivarailings.com www.vivarailings.com

4'-0" MAX

4'-0" MAX

MULTILINE

TOP RAIL

HAND RAIL

4" MAX.

Ø1-1/2" TUBE

3'-0"

HAND RAIL

3'-6"

TOP RAIL

2"x1" TUBE

2" MAX.

R4"

Ø2" TUBE

FINISH FLOOR

Ø1-1/2" iRAIL

1'-0"

CIRCA POST

STRINGER

MULTILINE

TOPTOP RAILRAIL OPTIONS OPTIONS

LEVEL 1 0'-0"

1'-0" VIVA RAILINGS IS NOT RESPONSIBLE FOR THE STRUCTURAL INTEGRITY OF ANY BUILDING SYSTEMS OR OTHER MATERIALS NOT FURNISHED BY VIVA RAILINGS. VIVA RAILINGS HAS NO WAY OF KNOWING AND SPECIFICALLY DISCLAIMS WHETHER OR NOT THE BUILDING SYSTEMS TO WHICH VIVA VIVA RAILINGS IS NOT RESPONSIBLE FOR THE STRUCTURAL INTEGRITY OF ANY BUILDING SYSTEMS OR OTHER MATERIALS NOT FURNISHED BY VIVA RAILINGS. VIVA RAILINGS HAS NO WAY OF KNOWING AND SPECIFICALLY DISCLAIMS WHETHER OR NOT THE BUILDING SYSTEMS TO WHICH VIVA RAILINGS’ PRODUCTS ARE TO BE ATTACHED ARE STRUCTURALLY SOUND OR DESIGNED TO PROPERLY SUPPORT RAILINGS' PRODUCTS ARE TO BE ATTACHED ARE STRUCTURALLY SOUND OR DESIGNED TO PROPERLY SUPPORT VIVA RAILINGS'S MATERIALS. ANY SUCH DESIGN RESPONSIBILITY BELONGS TO OTHERS FOR WHOM VIVA RAILINGS IS NOT RESPONSIBLE. VIVA RAILINGS’S MATERIALS. ANY SUCH DESIGN RESPONSIBILITY BELONGS TO OTHERS FOR WHOM VIVA RAILINGS IS NOT RESPONSIBLE. THESE DRAWINGS ARE INTENDED FOR THE SOLE USE OF VIVA RAILINGS’ CUSTOMER AND THEIR AGENTS FOR THE INSTALLATION OF PRODUCTS FURNISHED BY VIVA RAILINGS. VIVA RAILINGS REMAINS THE SOLE OWNER OF ALL DESIGNS AND INTELLECTUAL PROPERTY THESE DRAWINGS ARE INTENDED FOR THE SOLE USE VIVA RAILINGS' CUSTOMER THEIR THEPRODUCT INSTALLATION FURNISHED BY VIVA VIVA RAILINGS REMAINS THE SOLE OWNER OF ALL DESIGNS AND INTELLECTUAL PROPERTY CONTAINED WITHIN. CONTAINED WITHIN. REPRODUCTION AND USE OF THESE DESIGNS FOR ANY OF OTHER PURPOSE IS FORBIDDEN. SCALES AREAND PROVIDED FORAGENTS REFERENCEFOR ONLY. FOR INFORMATIONOF ANDPRODUCTS TECHNICAL SUPPORT, PLEASE CONTACT VIVA RAILINGS. RAILINGS. REPRODUCTION AND USE OF THESE DESIGNS FOR ANY OTHER PURPOSE IS FORBIDDEN. SCALES ARE PROVIDED FOR REFERENCE ONLY. FOR PRODUCT INFORMATION AND TECHNICAL SUPPORT, PLEASE CONTACT VIVA RAILINGS.

8

151 W. Vista Ridge Mall Dr. Lewisville, TX 75067

972-353-8482

info@vivarailings.com

vivarailings.com


V I V A

CIRCA RAILING SYSTEM

151 W. VISTA RIDGE MALL Dr. LEWISVILLE, TX 75067 P: 972-353-8482 F: 972-353-0013 e: info@vivarailings.com www.vivarailings.com

CIRCA RAILING SYSTEM CableNet Infill CABLENET INFILL

Page 2.7 OF 5

FRAME

3" 28

60°

1"

CABLENET

Ø1/16" [Ø1.5mm]

1" 48

PANEL

5'-0" MAX

CONTINUOUS

DIMENSIONS ARE NOMINAL

7x7 CONSTRUCTION CABLE

5'-0" MAX

CABLENET PANEL

TOP RAIL

HAND RAIL

3" NOM.

TOP RAIL

3'-0"

1" 44 NOM. GAP

Ø1-1/2" TUBE

3'-6"

HAND RAIL

2"x1" TUBE

2" NOM.

R4"

Ø2" TUBE

FINISH FLOOR

Ø1-1/2" iRAIL

1'-0"

CIRCA POST

STRINGER

CABLENET PANEL

RAIL OPTIONS TOPTOP RAIL OPTIONS

LEVEL 1 0'-0"

1'-0" VIVA RAILINGS IS NOT RESPONSIBLE FOR THE STRUCTURAL INTEGRITY OF ANY BUILDING SYSTEMS OR OTHER MATERIALS NOT FURNISHED BY VIVA RAILINGS. VIVA RAILINGS HAS NO WAY OF KNOWING AND SPECIFICALLY DISCLAIMS WHETHER OR NOT THE BUILDING SYSTEMS TO WHICH VIVA RAILINGS' PRODUCTS ARE TO BE ATTACHED ARE STRUCTURALLY SOUND OR DESIGNED TO PROPERLY SUPPORT VIVA RAILINGS'S MATERIALS. ANY SUCH DESIGN RESPONSIBILITY BELONGS TO OTHERS FOR WHOM VIVA RAILINGS IS NOT RESPONSIBLE. VIVATHESE RAILINGSDRAWINGS IS NOT RESPONSIBLE THE STRUCTURAL OF ANY BUILDING SYSTEMS OR OTHERCUSTOMER MATERIALS NOT AND FURNISHED BY VIVA RAILINGS.FOR VIVA RAILINGS HAS NO WAY OF KNOWING AND SPECIFICALLY DISCLAIMS WHETHER NOT THE BUILDING SYSTEMS TO WHICH VIVA RAILINGS’ ARE TO BEOF ATTACHED ARE STRUCTURALLY SOUND OR DESIGNEDPROPERTY TO PROPERLY SUPPORT AREFOR INTENDED FOR INTEGRITY THE SOLE USE OF VIVA RAILINGS' THEIR AGENTS THE INSTALLATION OF PRODUCTS FURNISHED BY VIVAORRAILINGS. VIVA RAILINGS REMAINS THEPRODUCTS SOLE OWNER ALL DESIGNS AND INTELLECTUAL CONTAINED WITHIN. VIVAREPRODUCTION RAILINGS’S MATERIALS.AND ANY SUCH RESPONSIBILITY BELONGS TOANY OTHERS FOR WHOM VIVA RAILINGS NOT RESPONSIBLE. THESE DRAWINGS ARE INTENDEDFOR FOR THE SOLE USE OF VIVA RAILINGS’ CUSTOMER AND THEIR AGENTS FOR THEAND INSTALLATION OF PRODUCTS FURNISHED BY VIVA RAILINGS. VIVA RAILINGS REMAINS THE SOLE OWNER OF ALL DESIGNS AND INTELLECTUAL PROPERTY USEDESIGN OF THESE DESIGNS FOR OTHER PURPOSE IS IS FORBIDDEN. SCALES ARE PROVIDED REFERENCE ONLY. FOR PRODUCT INFORMATION TECHNICAL SUPPORT, PLEASE CONTACT VIVA RAILINGS. CONTAINED WITHIN. REPRODUCTION AND USE OF THESE DESIGNS FOR ANY OTHER PURPOSE IS FORBIDDEN. SCALES ARE PROVIDED FOR REFERENCE ONLY. FOR PRODUCT INFORMATION AND TECHNICAL SUPPORT, PLEASE CONTACT VIVA RAILINGS.

151 W. Vista Ridge Mall Dr. Lewisville, TX 75067

972-353-8482

info@vivarailings.com

vivarailings.com

9


V I V A

TM

VIVA RAILINGS, LLC

CIRCA RAILING SYSTEM

151 W. VISTA RIDGE MALL Dr. LEWISVILLE, TX 75067

CIRCA RAILING SYSTEM CABLECable INFILL Infill

Page 2.6 OF 5

3 41" MAX.

P: 972-353-8482 F: 972-353-0013 e: info@vivarailings.com www.vivarailings.com

Stainless Steel 316 Cable Ø3/16", 1X19 Construction

4'-0" MAX

4'-0" MAX

CABLE

TOP RAIL

HAND RAIL

4" MAX.

Ø1-1/2" TUBE

3'-0"

HAND RAIL

3'-6"

TOP RAIL

2"x1" TUBE

3" MAX.

R4"

Ø2" TUBE

FINISH FLOOR

Ø1-1/2" iRAIL

1'-0"

CIRCA POST

STRINGER

CABLE

TOPTOP RAILRAIL OPTIONS OPTIONS

LEVEL 1 0'-0"

1'-0" VIVA RAILINGS IS NOT RESPONSIBLE FOR THE STRUCTURAL INTEGRITY OF ANY BUILDING SYSTEMS OR OTHER MATERIALS NOT FURNISHED BY VIVA RAILINGS. VIVA RAILINGS HAS NO WAY OF KNOWING AND SPECIFICALLY DISCLAIMS WHETHER OR NOT THE BUILDING SYSTEMS TO WHICH VIVA VIVA RAILINGS IS NOT RESPONSIBLE FOR THE STRUCTURAL INTEGRITY OF ANY BUILDING SYSTEMS OR OTHER MATERIALS NOT FURNISHED BY VIVA RAILINGS. VIVA RAILINGS HAS NO WAY OF KNOWING AND SPECIFICALLY DISCLAIMS WHETHER OR NOT THE BUILDING SYSTEMS TO WHICH VIVA RAILINGS’ PRODUCTS ARE TO BE ATTACHED ARE STRUCTURALLY SOUND OR DESIGNED TO PROPERLY SUPPORT RAILINGS' PRODUCTS ARE TO BE ATTACHED ARE STRUCTURALLY SOUND OR DESIGNED TO PROPERLY SUPPORT VIVA RAILINGS'S MATERIALS. ANY SUCH DESIGN RESPONSIBILITY BELONGS TO OTHERS FOR WHOM VIVA RAILINGS IS NOT RESPONSIBLE. VIVA RAILINGS’S MATERIALS. ANY SUCH DESIGN RESPONSIBILITY BELONGS TO OTHERS FOR WHOM VIVA RAILINGS IS NOT RESPONSIBLE. THESE DRAWINGS ARE INTENDED FOR THE SOLE USE OF VIVA RAILINGS’ CUSTOMER AND THEIR AGENTS FOR THE INSTALLATION OF PRODUCTS FURNISHED BY VIVA RAILINGS. VIVA RAILINGS REMAINS THE SOLE OWNER OF ALL DESIGNS AND INTELLECTUAL PROPERTY THESE DRAWINGS ARE INTENDED FOR THE SOLE USE VIVA RAILINGS' CUSTOMER THEIR THEPRODUCT INSTALLATION FURNISHED BY VIVA VIVA RAILINGS REMAINS THE SOLE OWNER OF ALL DESIGNS AND INTELLECTUAL PROPERTY CONTAINED WITHIN. CONTAINED WITHIN. REPRODUCTION AND USE OF THESE DESIGNS FOR ANY OF OTHER PURPOSE IS FORBIDDEN. SCALES AREAND PROVIDED FORAGENTS REFERENCEFOR ONLY. FOR INFORMATIONOF ANDPRODUCTS TECHNICAL SUPPORT, PLEASE CONTACT VIVA RAILINGS. RAILINGS. REPRODUCTION AND USE OF THESE DESIGNS FOR ANY OTHER PURPOSE IS FORBIDDEN. SCALES ARE PROVIDED FOR REFERENCE ONLY. FOR PRODUCT INFORMATION AND TECHNICAL SUPPORT, PLEASE CONTACT VIVA RAILINGS.

10

151 W. Vista Ridge Mall Dr. Lewisville, TX 75067

972-353-8482

info@vivarailings.com

vivarailings.com


V I V A

TM

VIVA RAILINGS, LLC

CIRCA RAILING SYSTEM

151 W. VISTA RIDGE MALL Dr. LEWISVILLE, TX 75067

CIRCA RAILING SYSTEM LASERLaser CUTcutINFILL w/ spiders P: 972-353-8482 F: 972-353-0013 e: info@vivarailings.com www.vivarailings.com

Page 2.1B OF 5 12/4/2023

SPIDER

Visit https://vivarailings.com/ for range of design patterns Or provide your custom pattern 5'-0" MAX

ALUMINUM PANEL

5'-0" MAX

TOP RAIL

HAND RAIL

3" NOM.

HAND RAIL

3'-0"

1" 32 NOM. GAP

Ø1-1/2" TUBE

3'-6"

TOP RAIL

2"x1" TUBE

2" NOM.

R4"

Ø2" TUBE

FINISH FLOOR

Ø1-1/2" iRAIL

1'-0"

CIRCA POST

STRINGER

LAMINATED GLASS

TOP RAIL OPTIONS TOP RAIL OPTIONS

LEVEL 1 0'-0"

1'-0" VIVA RAILINGS IS NOT RESPONSIBLE FOR THE STRUCTURAL INTEGRITY OF ANY BUILDING SYSTEMS OR OTHER MATERIALS NOT FURNISHED BY VIVA RAILINGS. VIVA RAILINGS HAS NO WAY OF KNOWING AND SPECIFICALLY DISCLAIMS WHETHER OR NOT THE BUILDING SYSTEMS TO WHICH VIVA RAILINGS' PRODUCTS ARE TO BE ATTACHED ARE STRUCTURALLY SOUND OR DESIGNED TO PROPERLY SUPPORT VIVA RAILINGS'S MATERIALS. ANY SUCH DESIGN RESPONSIBILITY BELONGS TO OTHERS FOR WHOM VIVA RAILINGS IS NOT RESPONSIBLE. THESE DRAWINGS ARE INTENDED FOR THE SOLE USE OF VIVA RAILINGS' CUSTOMER AND THEIR AGENTS FOR THE INSTALLATION OF PRODUCTS FURNISHED BY VIVA RAILINGS. VIVA RAILINGS REMAINS THE SOLE OWNER OF ALL DESIGNS AND INTELLECTUAL PROPERTY CONTAINED WITHIN. REPRODUCTION AND USE OF THESE DESIGNS FOR ANY OTHER PURPOSE IS FORBIDDEN. SCALES ARE PROVIDED FOR REFERENCE ONLY. FOR PRODUCT INFORMATION AND TECHNICAL SUPPORT, PLEASE CONTACT VIVA RAILINGS.

151 W. Vista Ridge Mall Dr. Lewisville, TX 75067

972-353-8482

info@vivarailings.com

vivarailings.com

11


TM

V I V A

VIVA RAILINGS, LLC

CIRCA RAILING SYSTEM

151 W. VISTA RIDGE MALL Dr. LEWISVILLE, TX 75067

CIRCA RAILING SYSTEM

P: 972-353-8482 F: 972-353-0013 e: info@vivarailings.com www.vivarailings.com

Page 3.1 OF 5

5" ⁴ MIN.

5" MIN.

Mounting Condition, TopPOST Mounted Post MOUNTING CONDITION, TOP MOUNTED

6" MIN.

6" MIN.

3" MIN.

Anchored to Concrete ¹ - $ ²

Cored into Concrete - $$

Welded @ Steel Channel - $

Detail# CA-T01 ³

Detail# CA-T02

Detail# CA-T03

Welded @ Embed Plate - $

4" MIN.

1" 62 MIN.

5" MIN.

3" MIN.

5" MIN.

Embed Plate (By others)

Anchored to Concrete Welded to Steel Plate - $

Anchored to Concrete Slab on Deck - $$

Detail# CA-T04 (1) Min. 4000 PSI concrete, Typ. (2) $ to $$$: Indicates mounting type comparative cost (3) Anchoring is not an available option for top mount with cable infill (4) 6 21" Min. for end post with cable infil

25 8"

3/8" BENT PLATE (BY OTHERS)

Detail# CA-T05

Detail# CA-T06

VIVA RAILINGS IS NOT RESPONSIBLE FOR THE STRUCTURAL INTEGRITY OF ANY BUILDING SYSTEMS OR OTHER MATERIALS NOT FURNISHED BY VIVA RAILINGS. VIVA RAILINGS HAS NO WAY OF KNOWING AND SPECIFICALLY DISCLAIMS WHETHER OR NOT THE BUILDING SYSTEMS TO WHICH VIVA VIVA RAILINGS IS NOT RESPONSIBLE FOR THE STRUCTURAL INTEGRITY OF ANY BUILDING SYSTEMS OR OTHER MATERIALS NOT FURNISHED BY VIVA RAILINGS. VIVA RAILINGS HAS NO WAY OF KNOWING AND SPECIFICALLY DISCLAIMS WHETHER OR NOT THE BUILDING SYSTEMS TO WHICH VIVA RAILINGS’ PRODUCTS ARE TO BE ATTACHED ARE STRUCTURALLY SOUND OR DESIGNED TO PROPERLY SUPPORT RAILINGS' PRODUCTS ARE TO BE ATTACHED ARE STRUCTURALLY SOUND OR DESIGNED TO PROPERLY SUPPORT VIVA RAILINGS'S MATERIALS. ANY SUCH DESIGN RESPONSIBILITY BELONGS TO OTHERS FOR WHOM VIVA RAILINGS IS NOT RESPONSIBLE. VIVA RAILINGS’S MATERIALS. ANY SUCH DESIGN RESPONSIBILITY BELONGS TO OTHERS FOR WHOM VIVA RAILINGS IS NOT RESPONSIBLE. THESE DRAWINGS ARE INTENDED FOR THE SOLE USE OF VIVA RAILINGS’ CUSTOMER AND THEIR AGENTS FOR THE INSTALLATION OF PRODUCTS FURNISHED BY VIVA RAILINGS. VIVA RAILINGS REMAINS THE SOLE OWNER OF ALL DESIGNS AND INTELLECTUAL PROPERTY THESE DRAWINGS ARE INTENDED FOR THE SOLE USE VIVA RAILINGS' CUSTOMER THEIR THEPRODUCT INSTALLATION FURNISHED BY VIVA VIVA RAILINGS REMAINS THE SOLE OWNER OF ALL DESIGNS AND INTELLECTUAL PROPERTY CONTAINED WITHIN. CONTAINED WITHIN. REPRODUCTION AND USE OF THESE DESIGNS FOR ANY OF OTHER PURPOSE IS FORBIDDEN. SCALES AREAND PROVIDED FORAGENTS REFERENCEFOR ONLY. FOR INFORMATIONOF ANDPRODUCTS TECHNICAL SUPPORT, PLEASE CONTACT VIVA RAILINGS. RAILINGS. REPRODUCTION AND USE OF THESE DESIGNS FOR ANY OTHER PURPOSE IS FORBIDDEN. SCALES ARE PROVIDED FOR REFERENCE ONLY. FOR PRODUCT INFORMATION AND TECHNICAL SUPPORT, PLEASE CONTACT VIVA RAILINGS.

12

151 W. Vista Ridge Mall Dr. Lewisville, TX 75067

972-353-8482

info@vivarailings.com

vivarailings.com


V I V A

CIRCA RAILING SYSTEM

151 W. VISTA RIDGE MALL Dr. LEWISVILLE, TX 75067 P: 972-353-8482 F: 972-353-0013 e: info@vivarailings.com www.vivarailings.com

CIRCA RAILING SYSTEM

Page 3.2 OF 5

Mounting Condition, Fascia Mounted Post MOUNTING CONDITION, FASCIA MOUNTED POST

6"

6"

6" MIN.

6"

6"

6" MIN.

Embed Plate (By others)

Anchored to Concrete ¹ - $$$

Welded @ Embed Plate - $$

Welded @ Steel Channel - $$

Detail# CA-F01 ²

Detail# CA-F02

Detail# CA-F03

STUD or DEFORMED REBAR (BY OTHERS)

6"

3" MIN.

6"

3" MIN.

3/8" THICK POUR STOP (BY OTHERS)

Welded @ Steel Tube - $$

Welded @ Pour Stop - $$

Detail# CA-F04

Detail# CA-F05

(1) Min. 4000 PSI concrete, Typ. (2) Anchoring is not a recommended option for cable infill VIVA RAILINGS IS NOT RESPONSIBLE FOR THE STRUCTURAL INTEGRITY OF ANY BUILDING SYSTEMS OR OTHER MATERIALS NOT FURNISHED BY VIVA RAILINGS. VIVA RAILINGS HAS NO WAY OF KNOWING AND SPECIFICALLY DISCLAIMS WHETHER OR NOT THE BUILDING SYSTEMS TO WHICH VIVA RAILINGS' PRODUCTS ARE TO BE ATTACHED ARE STRUCTURALLY SOUND OR DESIGNED TO PROPERLY SUPPORT VIVA RAILINGS'S MATERIALS. ANY SUCH DESIGN RESPONSIBILITY BELONGS TO OTHERS FOR WHOM VIVA RAILINGS IS NOT RESPONSIBLE. VIVATHESE RAILINGSDRAWINGS IS NOT RESPONSIBLE THE STRUCTURAL OF ANY BUILDING SYSTEMS OR OTHERCUSTOMER MATERIALS NOT AND FURNISHED BY VIVA RAILINGS.FOR VIVA RAILINGS HAS NO WAY OF KNOWING AND SPECIFICALLY DISCLAIMS WHETHER NOT THE BUILDING SYSTEMS TO WHICH VIVA RAILINGS’ ARE TO BEOF ATTACHED ARE STRUCTURALLY SOUND OR DESIGNEDPROPERTY TO PROPERLY SUPPORT AREFOR INTENDED FOR INTEGRITY THE SOLE USE OF VIVA RAILINGS' THEIR AGENTS THE INSTALLATION OF PRODUCTS FURNISHED BY VIVAORRAILINGS. VIVA RAILINGS REMAINS THEPRODUCTS SOLE OWNER ALL DESIGNS AND INTELLECTUAL CONTAINED WITHIN. VIVAREPRODUCTION RAILINGS’S MATERIALS.AND ANY SUCH RESPONSIBILITY BELONGS TOANY OTHERS FOR WHOM VIVA RAILINGS NOT RESPONSIBLE. THESE DRAWINGS ARE INTENDEDFOR FOR THE SOLE USE OF VIVA RAILINGS’ CUSTOMER AND THEIR AGENTS FOR THEAND INSTALLATION OF PRODUCTS FURNISHED BY VIVA RAILINGS. VIVA RAILINGS REMAINS THE SOLE OWNER OF ALL DESIGNS AND INTELLECTUAL PROPERTY USEDESIGN OF THESE DESIGNS FOR OTHER PURPOSE IS IS FORBIDDEN. SCALES ARE PROVIDED REFERENCE ONLY. FOR PRODUCT INFORMATION TECHNICAL SUPPORT, PLEASE CONTACT VIVA RAILINGS. CONTAINED WITHIN. REPRODUCTION AND USE OF THESE DESIGNS FOR ANY OTHER PURPOSE IS FORBIDDEN. SCALES ARE PROVIDED FOR REFERENCE ONLY. FOR PRODUCT INFORMATION AND TECHNICAL SUPPORT, PLEASE CONTACT VIVA RAILINGS.

151 W. Vista Ridge Mall Dr. Lewisville, TX 75067

972-353-8482

info@vivarailings.com

vivarailings.com

13


TM

V I V A

VIVA RAILINGS, LLC

CIRCA RAILING SYSTEM

151 W. VISTA RIDGE MALL Dr. LEWISVILLE, TX 75067

CIRCA RAILING SYSTEM

P: 972-353-8482 F: 972-353-0013 e: info@vivarailings.com www.vivarailings.com

Page 4 OF 5

Illuminated Railing ILLUMINATED RAILING

30° ASYM. LINEAR

SYM. LINEAR

1" Ø12

TOP RAIL

iRAIL Linear

SYM. POD

215 16"

36" TO FF

42" TO FF

ILLUMINATED HANDRAIL

iRAIL LINEAR ORIENTATION OPTIONS

22° ASYM. POD

1" Ø12

Illuminated Hand rail Option

18" 24" OR 36"

Illuminated Top rail Option

POD

iRAIL POD ORIENTATION OPTIONS

iRAIL POD SPACING OPTIONS

See Viva iRail Railing System for more info

iRAIL LIGHTED RAILING SYSTEM 14

151 W. Vista Ridge Mall Dr. Lewisville, TX 75067

972-353-8482

info@vivarailings.com

vivarailings.com


CIRCA GLASS RAILING SYSTEM

151 W. Vista Ridge Mall Dr. Lewisville, TX 75067

972-353-8482

info@vivarailings.com

vivarailings.com

15


CIRCA GLASS RAILING SYSTEM SHERMAN ISD NEW HIGH SCHOOL

SHERMAN ISD NEW HIGH SCHOOL - SHERMAN, TX General Contractor: Candence McShane Construction Architect: VLK Architects

16

151 W. Vista Ridge Mall Dr. Lewisville, TX 75067

972-353-8482

info@vivarailings.com

vivarailings.com


CIRCA GLASS RAILING SYSTEM PROSPER ISD ROCK HILL HIGH SCHOOL

PROSPER ISD ROCK HILL HIGH SCHOOL - PROSPER, TX General Contractor: Kaufman Lynn Construction Architect: PGAL Architects

151 W. Vista Ridge Mall Dr. Lewisville, TX 75067

972-353-8482

info@vivarailings.com

vivarailings.com

17


CIRCA GLASS RAILING SYSTEM SHERMAN ISD NEW HIGH SCHOOL

SHERMAN ISD NEW HIGH SCHOOL - SHERMAN, TX General Contractor: Candence McShane Construction Architect: VLK Architects

18

151 W. Vista Ridge Mall Dr. Lewisville, TX 75067

972-353-8482

info@vivarailings.com

vivarailings.com


CIRCA GLASS RAILING SYSTEM PROSPER ISD ROCK HILL HIGH SCHOOL

PROSPER ISD ROCK HILL HIGH SCHOOL - PROSPER, TX General Contractor: Kaufman Lynn Construction Architect: PGAL Architects

151 W. Vista Ridge Mall Dr. Lewisville, TX 75067

972-353-8482

info@vivarailings.com

vivarailings.com

19


NORTH AMERICA OPERATIONS

New York, NY Washington DC Kansas City, KS

151 W. Vista Ridge Mall Dr. Lewisville, TX 75067

San Diego, CA

Atlanta, GA

(Dallas/Fort Worth Metroplex)

Dallas/Fort Worth, TX

PH: 972.353.8482 | info@vivarailings.com vivarailings.com

Orlando, FL Regional Locations

Inc. Magazine 500 | 5000 VIVA RAILINGS, LLC. Among The Fastest Growing US Companies Eight Years in a Row 2012-2019

Inc. Magazine 500 | 5000 VIVA RAILINGS, LLC. Among The Fastest Growing Texas Companies #211

ICC-ES 4405 Certified

SHOE™ Structural Glass Railing System

LEED Material & Resources Credits 4.1 and 4.2

The American Institute of Architects

The California Contractors State License Board Certified

Version:120423


Turn static files into dynamic content formats.

Create a flipbook
CIRCA GLASS Product Data by viva.railings - Issuu