Skip to main content

BEACON Glass Product Data

Page 1

BEACON GLASS RAILING SYSTEM PRODUCT DATA ™

BEACON - AVAILABLE INFILLS Glass Perforated Metal Wire Mesh CableNet Cable LaserCut Panels

151 W. Vista Ridge Mall Dr. Lewisville, TX 75067

972-353-8482

info@vivarailings.com

vivarailings.com


BEACON GLASS RAILING SYSTEM ™

Our BEACON Stainless Steel Railing System has a modern design with clean lines. This sleek system consists of single flat bar posts that are available in a range of striking metallic colors to accent your interior layou

BEACON - AVAILABLE INFILLS Glass Perforated Metal Wire Mesh

BEACON GLASS CLAMP-11/11/22

CableNet Cable LaserCut Panels

Other mounting options available.

2

151 W. Vista Ridge Mall Dr. Lewisville, TX 75067

972-353-8482

info@vivarailings.com

vivarailings.com


BEACON GLASS & METAL SYSTEM - TECHNICAL DATA ™

MATERIAL

FINISH

#6 Satin, #8 Mirror

POST

Stainless Steel (304 or 316) ECM Stainless Steel (201)

Powder Coat

SIZE/SPACING

2” Flat bar @ 5’-0” max. O.C. for glass infill, 4’-6” max. for perforated and wire mesh infill. 2”x2” End post, 2” flat bar intermediate post @ 4’-0” max. for cable infill. Fascia, Top or Core mount.

Min. 3/8” laminated glass with PVB or SGP interlayer ¹ Glass standard thickness: 3/8”, 1/2” Glass with D-Clamps

Clear, Tinted or Frit Interlayer standard thickness, SGP: 0.035” , 0.06” PVB: 0.035”

Perforated Metal 1” wide frame Wire Mesh

INFILL OPTIONS

#6 Satin Cable

Ø3/16” cable

CableNet

Ø1” frame, Ø1/16” (1.5mm) cable mesh Powder Coat - Super Polyester (AAMA 2604) - $ 4 1/4” thick aluminum panel.

Laser Cut Powder Coat - PVDF (AAMA 2605) - $$ 4

Stainless Steel U-Cap

#6 Satin, Powder Coat

1” Height U-Cap for Glass Top Rail

Stainless Steel U-Cap with LED ³

#6 Satin

1” Height U-Cap with LED LINEAR for Glass Top Rail

Stainless Steel Tube

#6 Satin, Powder Coat

1. IBC 2015 & newer requires railing glass to be laminated. VIVA recommends SGP for exterior applications.

Ø1-1/2” or Ø2” for Hand Rail

2. All LED LINEAR products are ETL certified; ETL mark is proof of product compliance to North American safety standard.

Ø2” or 2”x1” Rectangular tube for Top Rail

TOP RAIL/HAND RAIL

3. Other species available upon request.

Stainless Steel Tube with LED

#6 Satin

Wood (Red Oak, Cherry or Maple) ²

Ø1-1/2” with LED LINEAR, Ø1-1/2” or Ø2” with LED POD

4. $ to $$$: Indicates finish type comparative cost.

Ø2” Unstained

Wood (Red Oak, Cherry or Maple) with LED

151 W. Vista Ridge Mall Dr. Lewisville, TX 75067

Ø2” with LED LINEAR

972-353-8482

info@vivarailings.com

vivarailings.com

3


I V A

VIVA RAILINGS, LLC

BEACON RAILING SYSTEM

1454 HALSEY WAY, CARROLLTON, TX 75007 P: 972-353-8482 F: 972-353-0013 e: info@vivarailings.com www.vivarailings.com

BEACON RAILING SYSTEM Glass Infill GLASS INFILL

Page 2.1 of 4 12/4/2023

GLASS OPTIONS: AVAILABLE

GLASS TYPES Clear Monolithic

Clear Laminated (PVB or SGP)

Bent

Tinted

Satin Etched

Ceramic Frit

Colored Laminate (PVB only)

D-CLAMP TYPE OPTIONS POST

FITTING

BD-1

Stainless Steel, Satin

Stainless Steel D-Clamp

BD-2

Stainless Steel, ECM

ECM D-Clamp

BD-3

Powder Coated

Stainless Steel, Satin D-Clamp

5'-0" MAX

LAMINATED GLASS

TOP RAIL

HAND RAIL

G02

G03

Ø1-1/2" TUBE

3'-0"

3" 28 NOM. GAP

2"x1" TUBE

2" NOM.

G01

HAND RAIL

3" NOM.

TOP RAIL

R4"

Ø2" TUBE

3'-6"

5'-0" MAX

CODE

FINISH FLOOR

Ø1-1/2" iRAIL

1'-0"

BEACON POST

STRINGER

LAMINATED GLASS

TOPTOP RAILRAIL OPTIONS OPTIONS

LEVEL 1 0'-0"

1'-0" VIVA RAILINGS IS NOT RESPONSIBLE FOR THE STRUCTURAL INTEGRITY OF ANY BUILDING SYSTEMS OR OTHER MATERIALS NOT FURNISHED BY VIVA RAILINGS. VIVA RAILINGS HAS NO WAY OF KNOWING AND SPECIFICALLY DISCLAIMS WHETHER OR NOT THE BUILDING SYSTEMS TO WHICH VIVA RAILINGS' PRODUCTS ARE TO BE ATTACHED ARE STRUCTURALLY SOUND OR DESIGNED TO PROPERLY SUPPORT VIVA RAILINGS'S MATERIALS. ANY SUCH DESIGN RESPONSIBILITY BELONGS TO OTHERS FOR WHOM VIVA RAILINGS IS NOT RESPONSIBLE. ARE FOR INTENDED FOR INTEGRITY THE SOLE USE OF VIVA RAILINGS' THEIR AGENTS FOR THE INSTALLATION OF PRODUCTS FURNISHED BY VIVAORRAILINGS. VIVA RAILINGS REMAINS THEPRODUCTS SOLE OWNER ALL DESIGNS AND INTELLECTUAL CONTAINED WITHIN. VIVATHESE RAILINGSDRAWINGS IS NOT RESPONSIBLE THE STRUCTURAL OF ANY BUILDING SYSTEMS OR OTHERCUSTOMER MATERIALS NOT AND FURNISHED BY VIVA RAILINGS. VIVA RAILINGS HAS NO WAY OF KNOWING AND SPECIFICALLY DISCLAIMS WHETHER NOT THE BUILDING SYSTEMS TO WHICH VIVA RAILINGS’ ARE TO BEOF ATTACHED ARE STRUCTURALLY SOUND OR DESIGNEDPROPERTY TO PROPERLY SUPPORT VIVAREPRODUCTION RAILINGS’S MATERIALS.AND ANY SUCH RESPONSIBILITY BELONGS TOANY OTHERS FOR WHOM VIVA RAILINGS IS NOT RESPONSIBLE. THESE DRAWINGS ARE INTENDEDFOR FOR THE SOLE USE OF VIVA RAILINGS’ CUSTOMER AND THEIR AGENTS FOR THEAND INSTALLATION OF PRODUCTS FURNISHED BY VIVA RAILINGS. VIVA RAILINGS REMAINS THE SOLE OWNER OF ALL DESIGNS AND INTELLECTUAL PROPERTY USEDESIGN OF THESE DESIGNS FOR OTHER PURPOSE IS FORBIDDEN. SCALES ARE PROVIDED REFERENCE ONLY. FOR PRODUCT INFORMATION TECHNICAL SUPPORT, PLEASE CONTACT VIVA RAILINGS. CONTAINED WITHIN. REPRODUCTION AND USE OF THESE DESIGNS FOR ANY OTHER PURPOSE IS FORBIDDEN. SCALES ARE PROVIDED FOR REFERENCE ONLY. FOR PRODUCT INFORMATION AND TECHNICAL SUPPORT, PLEASE CONTACT VIVA RAILINGS.

4

151 W. Vista Ridge Mall Dr. Lewisville, TX 75067

972-353-8482

info@vivarailings.com

vivarailings.com


V I V A

TM

VIVA RAILINGS, LLC

BEACON RAILING SYSTEM

BEACON RAILING SYSTEM PERFORATED METAL INFILL Perforated Metal Infill 1454 HALSEY WAY, CARROLLTON, TX 75007

P: 972-353-8482 F: 972-353-0013 e: info@vivarailings.com www.vivarailings.com

Page 2.2 of 4 12/4/2023

1"

9 16"

AVAILABLE AVAILABLE PERFORATEDTYPES TYPES: PERFORATED

1 16" (14 GA)

1" Ø4

3" Ø8

9 16"

PMRO-1014

1 8"

PMRO-0610

11 16"

1" Ø2

PMRO-1217

4'-6" MAX

5 16"

7" 8

CLAMP 3" 5" 8 8

PMSQ-1013

PERFORATED METAL

TOP RAIL

PA02

PA03

13 16"

PMSL-1122

Ø2" TUBE

2"x1" TUBE

2" NOM.

R4"

7 16"

Ø1-1/2" TUBE

3'-0"

2" NOM. GAP

PA01

HAND RAIL

3" NOM.

HAND RAIL

13 4"

PMSL-0325

4'-6" MAX

TOP RAIL

1"

3'-6"

SPIDER

SECTION VIEW

1" 116

3 8"

FINISH FLOOR

Ø1-1/2" iRAIL

1'-0"

BEACON POST

STRINGER

PERFORATED METAL

TOPTOP RAILRAIL OPTIONS OPTIONS

LEVEL 1 0'-0"

1'-0" VIVA RAILINGS IS NOT RESPONSIBLE FOR THE STRUCTURAL INTEGRITY OF ANY BUILDING SYSTEMS OR OTHER MATERIALS NOT FURNISHED BY VIVA RAILINGS. VIVA RAILINGS HAS NO WAY OF KNOWING AND SPECIFICALLY DISCLAIMS WHETHER OR NOT THE BUILDING SYSTEMS TO WHICH VIVA RAILINGS’ PRODUCTS ARE TO BE ATTACHED ARE STRUCTURALLY SOUND OR DESIGNED TO PROPERLY SUPPORT RAILINGS IS ANY NOT RESPONSIBLE FOR THE STRUCTURAL OF ANY SYSTEMS OR OTHER MATERIALS NOT VIVA RAILINGS. VIVA RAILINGS HAS NO WAY OF KNOWING AND SPECIFICALLY DISCLAIMS WHETHER ORDESIGNS NOT THE BUILDING PROPERTY SYSTEMS TO WHICH VIVA VIVAVIVA RAILINGS’S MATERIALS. SUCH DESIGN RESPONSIBILITY BELONGS TO OTHERS FOR INTEGRITY WHOM VIVA RAILINGS IS NOTBUILDING RESPONSIBLE. THESE DRAWINGS ARE INTENDED FOR THE SOLE USEFURNISHED OF VIVA RAILINGS’BY CUSTOMER AND THEIR AGENTS FOR THE INSTALLATION OF PRODUCTS FURNISHED BY VIVA RAILINGS. VIVA RAILINGS REMAINS THE SOLE OWNER OF ALL AND INTELLECTUAL RAILINGS' TOOF BETHESE ATTACHED ARE SOUNDSCALES OR DESIGNED SUPPORT VIVA RAILINGS'S MATERIALS. ANY SUCH DESIGN RESPONSIBILITY BELONGS TO OTHERS FOR WHOM VIVA RAILINGS IS NOT RESPONSIBLE. CONTAINED WITHIN.PRODUCTS REPRODUCTIONARE AND USE DESIGNS FOR ANYSTRUCTURALLY OTHER PURPOSE IS FORBIDDEN. ARE PROVIDEDTO FORPROPERLY REFERENCE ONLY. FOR PRODUCT INFORMATION AND TECHNICAL SUPPORT, PLEASE CONTACT VIVA RAILINGS.

THESE DRAWINGS ARE INTENDED FOR THE SOLE USE OF VIVA RAILINGS' CUSTOMER AND THEIR AGENTS FOR THE INSTALLATION OF PRODUCTS FURNISHED BY VIVA RAILINGS. VIVA RAILINGS REMAINS THE SOLE OWNER OF ALL DESIGNS AND INTELLECTUAL PROPERTY CONTAINED WITHIN. REPRODUCTION AND USE OF THESE DESIGNS FOR ANY OTHER PURPOSE IS FORBIDDEN. SCALES ARE PROVIDED FOR REFERENCE ONLY. FOR PRODUCT INFORMATION AND TECHNICAL SUPPORT, PLEASE CONTACT VIVA RAILINGS.

151 W. Vista Ridge Mall Dr. Lewisville, TX 75067

972-353-8482

info@vivarailings.com

vivarailings.com

5


VIVA RAILINGS, LLC

BEACON RAILING SYSTEM

1454 HALSEY WAY, CARROLLTON, TX 75007

1 2" 9 16" TYP.

1" 28

33 4"

17 8"

113 16"

5" 116

7 16"

7 16"

AVAILABLE AVAILABLE WIRE MESH TYPES WIREMESH TYPES:

Page 2.3 of 4 12/4/2023

7" 8

BEACON RAILING SYSTEM WIRE Wire MESH INFILL Mesh Infill

P: 972-353-8482 F: 972-353-0013 e: info@vivarailings.com www.vivarailings.com

1" TYP.

V I V A

TM

WM-10

WM-13

WM-12

WM-14

SPIDER

15" 16 3" 8

1" 116 9 16"

13" 16

17 8" 5" 8

11 16"

7 16"

WM-11

CLAMP WM-15

4'-6" MAX

WM-19

WM-17

WM-20

4'-6" MAX

WIRE MESH

TOP RAIL

PA02

PA03

3'-0"

2" NOM. GAP

2"x1" TUBE

2" NOM.

PA01

Ø1-1/2" TUBE

3'-6"

HAND RAIL

R4"

Ø2" TUBE

HAND RAIL

3" NOM.

TOP RAIL

WM-21

FINISH FLOOR

Ø1-1/2" iRAIL

1'-0"

BEACON POST

STRINGER

WIRE MESH

TOPTOP RAILRAIL OPTIONS OPTIONS

LEVEL 1 0'-0"

1'-0" VIVA RAILINGS IS NOT RESPONSIBLE FOR THE STRUCTURAL INTEGRITY OF ANY BUILDING SYSTEMS OR OTHER MATERIALS NOT FURNISHED BY VIVA RAILINGS. VIVA RAILINGS HAS NO WAY OF KNOWING AND SPECIFICALLY DISCLAIMS WHETHER OR NOT THE BUILDING SYSTEMS TO WHICH VIVA VIVA RAILINGS IS NOT RESPONSIBLE FOR THE STRUCTURAL INTEGRITY OF ANY BUILDING SYSTEMS OR OTHER MATERIALS NOT FURNISHED BY VIVA RAILINGS. VIVA RAILINGS HAS NO WAY OF KNOWING AND SPECIFICALLY DISCLAIMS WHETHER OR NOT THE BUILDING SYSTEMS TO WHICH VIVA RAILINGS’ PRODUCTS ARE TO BE ATTACHED ARE STRUCTURALLY SOUND OR DESIGNED TO PROPERLY SUPPORT RAILINGS' PRODUCTS ARE TO BE ATTACHED ARE STRUCTURALLY SOUND OR DESIGNED TO PROPERLY SUPPORT VIVA RAILINGS'S MATERIALS. ANY SUCH DESIGN RESPONSIBILITY BELONGS TO OTHERS FOR WHOM VIVA RAILINGS IS NOT RESPONSIBLE. VIVA RAILINGS’S MATERIALS. ANY SUCH DESIGN RESPONSIBILITY BELONGS TO OTHERS FOR WHOM VIVA RAILINGS IS NOT RESPONSIBLE. THESE DRAWINGS ARE INTENDED FOR THE SOLE USE OF VIVA RAILINGS’ CUSTOMER AND THEIR AGENTS FOR THE INSTALLATION OF PRODUCTS FURNISHED BY VIVA RAILINGS. VIVA RAILINGS REMAINS THE SOLE OWNER OF ALL DESIGNS AND INTELLECTUAL PROPERTY THESE DRAWINGS ARE INTENDED FOR THE SOLE USE VIVA RAILINGS' CUSTOMER THEIR THEPRODUCT INSTALLATION FURNISHED BY VIVA VIVA RAILINGS REMAINS THE SOLE OWNER OF ALL DESIGNS AND INTELLECTUAL PROPERTY CONTAINED WITHIN. CONTAINED WITHIN. REPRODUCTION AND USE OF THESE DESIGNS FOR ANY OF OTHER PURPOSE IS FORBIDDEN. SCALES AREAND PROVIDED FORAGENTS REFERENCEFOR ONLY. FOR INFORMATIONOF ANDPRODUCTS TECHNICAL SUPPORT, PLEASE CONTACT VIVA RAILINGS. RAILINGS. REPRODUCTION AND USE OF THESE DESIGNS FOR ANY OTHER PURPOSE IS FORBIDDEN. SCALES ARE PROVIDED FOR REFERENCE ONLY. FOR PRODUCT INFORMATION AND TECHNICAL SUPPORT, PLEASE CONTACT VIVA RAILINGS.

6

151 W. Vista Ridge Mall Dr. Lewisville, TX 75067

972-353-8482

info@vivarailings.com

vivarailings.com


V I V A

VIVA RAILINGS, LLC

BEACON RAILING SYSTEM

1454 HALSEY WAY, CARROLLTON, TX 75007 P: 972-353-8482 F: 972-353-0013 e: info@vivarailings.com www.vivarailings.com

3 41" MAX.

BEACON RAILING SYSTEM Infill CABLECable INFILL

Page 2.4 of 4 12/4/2023

Stainless Steel 316 Cable Ø3/16", 1X19 Construction

4'-0" MAX

4'-0" MAX

CABLE

TOP RAIL

HAND RAIL

4" MAX.

Ø1-1/2" TUBE

3'-0"

HAND RAIL

3'-6"

TOP RAIL

2"x1" TUBE

3" MAX.

R4"

Ø2" TUBE

FINISH FLOOR

Ø1-1/2" iRAIL

1'-0"

BEACON POST

STRINGER

CABLE

RAIL OPTIONS TOPTOP RAIL OPTIONS

LEVEL 1 0'-0"

1'-0" VIVA RAILINGS IS NOT RESPONSIBLE FOR THE STRUCTURAL INTEGRITY OF ANY BUILDING SYSTEMS OR OTHER MATERIALS NOT FURNISHED BY VIVA RAILINGS. VIVA RAILINGS HAS NO WAY OF KNOWING AND SPECIFICALLY DISCLAIMS WHETHER OR NOT THE BUILDING SYSTEMS TO WHICH VIVA RAILINGS' PRODUCTS ARE TO BE ATTACHED ARE STRUCTURALLY SOUND OR DESIGNED TO PROPERLY SUPPORT VIVA RAILINGS'S MATERIALS. ANY SUCH DESIGN RESPONSIBILITY BELONGS TO OTHERS FOR WHOM VIVA RAILINGS IS NOT RESPONSIBLE. VIVATHESE RAILINGSDRAWINGS IS NOT RESPONSIBLE THE STRUCTURAL OF ANY BUILDING SYSTEMS OR OTHERCUSTOMER MATERIALS NOT AND FURNISHED BY VIVA RAILINGS.FOR VIVA RAILINGS HAS NO WAY OF KNOWING AND SPECIFICALLY DISCLAIMS WHETHER NOT THE BUILDING SYSTEMS TO WHICH VIVA RAILINGS’ ARE TO BEOF ATTACHED ARE STRUCTURALLY SOUND OR DESIGNEDPROPERTY TO PROPERLY SUPPORT AREFOR INTENDED FOR INTEGRITY THE SOLE USE OF VIVA RAILINGS' THEIR AGENTS THE INSTALLATION OF PRODUCTS FURNISHED BY VIVAORRAILINGS. VIVA RAILINGS REMAINS THEPRODUCTS SOLE OWNER ALL DESIGNS AND INTELLECTUAL CONTAINED WITHIN. VIVAREPRODUCTION RAILINGS’S MATERIALS.AND ANY SUCH RESPONSIBILITY BELONGS TOANY OTHERS FOR WHOM VIVA RAILINGS NOT RESPONSIBLE. THESE DRAWINGS ARE INTENDEDFOR FOR THE SOLE USE OF VIVA RAILINGS’ CUSTOMER AND THEIR AGENTS FOR THEAND INSTALLATION OF PRODUCTS FURNISHED BY VIVA RAILINGS. VIVA RAILINGS REMAINS THE SOLE OWNER OF ALL DESIGNS AND INTELLECTUAL PROPERTY USEDESIGN OF THESE DESIGNS FOR OTHER PURPOSE IS IS FORBIDDEN. SCALES ARE PROVIDED REFERENCE ONLY. FOR PRODUCT INFORMATION TECHNICAL SUPPORT, PLEASE CONTACT VIVA RAILINGS. CONTAINED WITHIN. REPRODUCTION AND USE OF THESE DESIGNS FOR ANY OTHER PURPOSE IS FORBIDDEN. SCALES ARE PROVIDED FOR REFERENCE ONLY. FOR PRODUCT INFORMATION AND TECHNICAL SUPPORT, PLEASE CONTACT VIVA RAILINGS.

151 W. Vista Ridge Mall Dr. Lewisville, TX 75067

972-353-8482

info@vivarailings.com

vivarailings.com

7


V I V A

TM

VIVA RAILINGS, LLC

BEACON RAILING SYSTEM

1454 HALSEY WAY, CARROLLTON, TX 75007

BEACON RAILING SYSTEM CABLENET INFILL CableNet Infill

P: 972-353-8482 F: 972-353-0013 e: info@vivarailings.com www.vivarailings.com

Page 2.5 of 4 12/4/2023

FRAME

3" 28

60°

1"

CABLENET

Ø1/16" [Ø1.5mm]

1" 48

PANEL

5'-0" MAX

CONTINUOUS

DIMENSIONS ARE NOMINAL

5'-0" MAX

TOP RAIL

7x7 CONSTRUCTION CABLE

CABLENET PANEL

Ø2" TUBE

HAND RAIL

3" NOM.

TOP RAIL

HAND RAIL CP11

3'-0"

27 8" NOM. GAP

2"x1" TUBE

2" NOM.

CP10

3'-6"

CP11

Ø1-1/2" TUBE

R4"

FINISH FLOOR

Ø1-1/2" iRAIL

1'-0"

BEACON POST

STRINGER

CABLENET PANEL

TOPTOP RAILRAIL OPTIONS OPTIONS

LEVEL 1 0'-0"

1'-0" VIVA RAILINGS IS NOT RESPONSIBLE FOR THE STRUCTURAL INTEGRITY OF ANY BUILDING SYSTEMS OR OTHER MATERIALS NOT FURNISHED BY VIVA RAILINGS. VIVA RAILINGS HAS NO WAY OF KNOWING AND SPECIFICALLY DISCLAIMS WHETHER OR NOT THE BUILDING SYSTEMS TO WHICH VIVA VIVA RAILINGS IS NOT RESPONSIBLE FOR THE STRUCTURAL INTEGRITY OF ANY BUILDING SYSTEMS OR OTHER MATERIALS NOT FURNISHED BY VIVA RAILINGS. VIVA RAILINGS HAS NO WAY OF KNOWING AND SPECIFICALLY DISCLAIMS WHETHER OR NOT THE BUILDING SYSTEMS TO WHICH VIVA RAILINGS’ PRODUCTS ARE TO BE ATTACHED ARE STRUCTURALLY SOUND OR DESIGNED TO PROPERLY SUPPORT RAILINGS' PRODUCTS ARE TO BE ATTACHED ARE STRUCTURALLY SOUND OR DESIGNED TO PROPERLY SUPPORT VIVA RAILINGS'S MATERIALS. ANY SUCH DESIGN RESPONSIBILITY BELONGS TO OTHERS FOR WHOM VIVA RAILINGS IS NOT RESPONSIBLE. VIVA RAILINGS’S MATERIALS. ANY SUCH DESIGN RESPONSIBILITY BELONGS TO OTHERS FOR WHOM VIVA RAILINGS IS NOT RESPONSIBLE. THESE DRAWINGS ARE INTENDED FOR THE SOLE USE OF VIVA RAILINGS’ CUSTOMER AND THEIR AGENTS FOR THE INSTALLATION OF PRODUCTS FURNISHED BY VIVA RAILINGS. VIVA RAILINGS REMAINS THE SOLE OWNER OF ALL DESIGNS AND INTELLECTUAL PROPERTY THESE DRAWINGS ARE INTENDED FOR THE SOLE USE VIVA RAILINGS' CUSTOMER THEIR THEPRODUCT INSTALLATION FURNISHED BY VIVA VIVA RAILINGS REMAINS THE SOLE OWNER OF ALL DESIGNS AND INTELLECTUAL PROPERTY CONTAINED WITHIN. CONTAINED WITHIN. REPRODUCTION AND USE OF THESE DESIGNS FOR ANY OF OTHER PURPOSE IS FORBIDDEN. SCALES AREAND PROVIDED FORAGENTS REFERENCEFOR ONLY. FOR INFORMATIONOF ANDPRODUCTS TECHNICAL SUPPORT, PLEASE CONTACT VIVA RAILINGS. RAILINGS. REPRODUCTION AND USE OF THESE DESIGNS FOR ANY OTHER PURPOSE IS FORBIDDEN. SCALES ARE PROVIDED FOR REFERENCE ONLY. FOR PRODUCT INFORMATION AND TECHNICAL SUPPORT, PLEASE CONTACT VIVA RAILINGS.

8

151 W. Vista Ridge Mall Dr. Lewisville, TX 75067

972-353-8482

info@vivarailings.com

vivarailings.com


V I V A

TM

VIVA RAILINGS, LLC

BEACON RAILING SYSTEM

151 W. VISTA RIDGE MALL Dr. LEWISVILLE, TX 75067

BEACON RAILING SYSTEM LASERLaser CUTcutINFILL w/ spiders P: 972-353-8482 F: 972-353-0013 e: info@vivarailings.com www.vivarailings.com

Page 2.1B OF 5 12/4/2023

Visit https://vivarailings.com/ for range of design patterns Or provide your custom pattern 5'-0" MAX

ALUMINUM PANEL

5'-0" MAX

TOP RAIL

HAND RAIL

3" NOM.

HAND RAIL

3'-0"

2" NOM. GAP

Ø1-1/2" TUBE

3'-6"

TOP RAIL

2"x1" TUBE

2" NOM.

R4"

Ø2" TUBE

FINISH FLOOR

Ø1-1/2" iRAIL

1'-0"

BEACON POST

STRINGER

ALUMINUM PANEL

TOP TOPRAIL RAIL OPTIONS OPTIONS

LEVEL 1 0'-0"

1'-0" VIVA RAILINGS IS NOT RESPONSIBLE FOR THE STRUCTURAL INTEGRITY OF ANY BUILDING SYSTEMS OR OTHER MATERIALS NOT FURNISHED BY VIVA RAILINGS. VIVA RAILINGS HAS NO WAY OF KNOWING AND SPECIFICALLY DISCLAIMS WHETHER OR NOT THE BUILDING SYSTEMS TO WHICH VIVA RAILINGS' PRODUCTS ARE TO BE ATTACHED ARE STRUCTURALLY SOUND OR DESIGNED TO PROPERLY SUPPORT VIVA RAILINGS'S MATERIALS. ANY SUCH DESIGN RESPONSIBILITY BELONGS TO OTHERS FOR WHOM VIVA RAILINGS IS NOT RESPONSIBLE. THESE DRAWINGS ARE INTENDED FOR THE SOLE USE OF VIVA RAILINGS' CUSTOMER AND THEIR AGENTS FOR THE INSTALLATION OF PRODUCTS FURNISHED BY VIVA RAILINGS. VIVA RAILINGS REMAINS THE SOLE OWNER OF ALL DESIGNS AND INTELLECTUAL PROPERTY CONTAINED WITHIN. REPRODUCTION AND USE OF THESE DESIGNS FOR ANY OTHER PURPOSE IS FORBIDDEN. SCALES ARE PROVIDED FOR REFERENCE ONLY. FOR PRODUCT INFORMATION AND TECHNICAL SUPPORT, PLEASE CONTACT VIVA RAILINGS.

151 W. Vista Ridge Mall Dr. Lewisville, TX 75067

972-353-8482

info@vivarailings.com

vivarailings.com

9


TM

V I V A

VIVA RAILINGS, LLC

BEACON RAILING SYSTEM

1454 HALSEY WAY, CARROLLTON, TX 75007

BEACON RAILING SYSTEM

P: 972-353-8482 F: 972-353-0013 e: info@vivarailings.com www.vivarailings.com

Page 3.1 of 4 12/4/2023

5" ⁴ MIN.

5" MIN.

Mounting Condition, TopPOST Mounted Post MOUNTING CONDITION, TOP MOUNTED

6" MIN.

6" MIN. 3" MIN.

Anchored to Concrete ¹ - $ ²

Cored into Concrete - $$

Welded @ Steel Channel - $

Detail# BE-T01 ³

Detail# BE-T02

Detail# BE-T03

6" MIN.

Welded @ Embed Plate - $

6" MIN.

5" MIN.

1" 34 MIN.

5" MIN.

Embed Plate (By others)

Anchored to Concrete Welded to Steel Plate - $

Anchored to Concrete Slab on Deck - $$

Detail# BE-T04 (1) Min. 4000 PSI concrete, Typ. (2) $ to $$$: Indicates mounting type comparative cost (3) Anchoring is not an available option for top mount with cable infill (4) 6 21" Min. for end post with cable infil

5" 28

3/8" BENT PLATE (BY OTHERS)

Detail# BE-T05

Detail# BE-T06

VIVA RAILINGS IS NOT RESPONSIBLE FOR THE STRUCTURAL INTEGRITY OF ANY BUILDING SYSTEMS OR OTHER MATERIALS NOT FURNISHED BY VIVA RAILINGS. VIVA RAILINGS HAS NO WAY OF KNOWING AND SPECIFICALLY DISCLAIMS WHETHER OR NOT THE BUILDING SYSTEMS TO WHICH VIVA VIVA RAILINGS IS NOT RESPONSIBLE FOR THE STRUCTURAL INTEGRITY OF ANY BUILDING SYSTEMS OR OTHER MATERIALS NOT FURNISHED BY VIVA RAILINGS. VIVA RAILINGS HAS NO WAY OF KNOWING AND SPECIFICALLY DISCLAIMS WHETHER OR NOT THE BUILDING SYSTEMS TO WHICH VIVA RAILINGS’ PRODUCTS ARE TO BE ATTACHED ARE STRUCTURALLY SOUND OR DESIGNED TO PROPERLY SUPPORT RAILINGS' PRODUCTS ARE TO BE ATTACHED ARE STRUCTURALLY SOUND OR DESIGNED TO PROPERLY SUPPORT VIVA RAILINGS'S MATERIALS. ANY SUCH DESIGN RESPONSIBILITY BELONGS TO OTHERS FOR WHOM VIVA RAILINGS IS NOT RESPONSIBLE. VIVA RAILINGS’S MATERIALS. ANY SUCH DESIGN RESPONSIBILITY BELONGS TO OTHERS FOR WHOM VIVA RAILINGS IS NOT RESPONSIBLE. THESE DRAWINGS ARE INTENDED FOR THE SOLE USE OF VIVA RAILINGS’ CUSTOMER AND THEIR AGENTS FOR THE INSTALLATION OF PRODUCTS FURNISHED BY VIVA RAILINGS. VIVA RAILINGS REMAINS THE SOLE OWNER OF ALL DESIGNS AND INTELLECTUAL PROPERTY THESE DRAWINGS ARE INTENDED FOR THE SOLE USE VIVA RAILINGS' CUSTOMER THEIR THEPRODUCT INSTALLATION FURNISHED BY VIVA VIVA RAILINGS REMAINS THE SOLE OWNER OF ALL DESIGNS AND INTELLECTUAL PROPERTY CONTAINED WITHIN. CONTAINED WITHIN. REPRODUCTION AND USE OF THESE DESIGNS FOR ANY OF OTHER PURPOSE IS FORBIDDEN. SCALES AREAND PROVIDED FORAGENTS REFERENCEFOR ONLY. FOR INFORMATIONOF ANDPRODUCTS TECHNICAL SUPPORT, PLEASE CONTACT VIVA RAILINGS. RAILINGS. REPRODUCTION AND USE OF THESE DESIGNS FOR ANY OTHER PURPOSE IS FORBIDDEN. SCALES ARE PROVIDED FOR REFERENCE ONLY. FOR PRODUCT INFORMATION AND TECHNICAL SUPPORT, PLEASE CONTACT VIVA RAILINGS.

10

151 W. Vista Ridge Mall Dr. Lewisville, TX 75067

972-353-8482

info@vivarailings.com

vivarailings.com


V I V A

VIVA RAILINGS, LLC

BEACON RAILING SYSTEM

1454 HALSEY WAY, CARROLLTON, TX 75007 P: 972-353-8482 F: 972-353-0013 e: info@vivarailings.com www.vivarailings.com

BEACON RAILING SYSTEM

Page 3.2 of 4 12/4/2023

Mounting Condition, Fascia Mounted Post MOUNTING CONDITION, FASCIA MOUNTED POST

6"

6"

6" MIN.

6"

6"

6" MIN.

Embed Plate (By others)

Anchored to Concrete ¹ - $$$

Welded @ Embed Plate - $$

Welded @ Steel Channel - $$

Detail# BE-F01 ²

Detail# BE-F02

Detail# BE-F03

STUD or DEFORMED REBAR (BY OTHERS)

6"

3" MIN.

6"

3" MIN.

3/8" THICK POUR STOP (BY OTHERS)

Welded @ Steel Tube - $$

Welded @ Pour Stop - $$

Detail# BE-F04

Detail# BE-F05

(1) Min. 4000 PSI concrete, Typ. (2) Anchoring is not a recommended option for cable infill VIVA RAILINGS IS NOT RESPONSIBLE FOR THE STRUCTURAL INTEGRITY OF ANY BUILDING SYSTEMS OR OTHER MATERIALS NOT FURNISHED BY VIVA RAILINGS. VIVA RAILINGS HAS NO WAY OF KNOWING AND SPECIFICALLY DISCLAIMS WHETHER OR NOT THE BUILDING SYSTEMS TO WHICH VIVA RAILINGS' PRODUCTS ARE TO BE ATTACHED ARE STRUCTURALLY SOUND OR DESIGNED TO PROPERLY SUPPORT VIVA RAILINGS'S MATERIALS. ANY SUCH DESIGN RESPONSIBILITY BELONGS TO OTHERS FOR WHOM VIVA RAILINGS IS NOT RESPONSIBLE. VIVATHESE RAILINGSDRAWINGS IS NOT RESPONSIBLE THE STRUCTURAL OF ANY BUILDING SYSTEMS OR OTHERCUSTOMER MATERIALS NOT AND FURNISHED BY VIVA RAILINGS.FOR VIVA RAILINGS HAS NO WAY OF KNOWING AND SPECIFICALLY DISCLAIMS WHETHER NOT THE BUILDING SYSTEMS TO WHICH VIVA RAILINGS’ ARE TO BEOF ATTACHED ARE STRUCTURALLY SOUND OR DESIGNEDPROPERTY TO PROPERLY SUPPORT AREFOR INTENDED FOR INTEGRITY THE SOLE USE OF VIVA RAILINGS' THEIR AGENTS THE INSTALLATION OF PRODUCTS FURNISHED BY VIVAORRAILINGS. VIVA RAILINGS REMAINS THEPRODUCTS SOLE OWNER ALL DESIGNS AND INTELLECTUAL CONTAINED WITHIN. VIVAREPRODUCTION RAILINGS’S MATERIALS.AND ANY SUCH RESPONSIBILITY BELONGS TOANY OTHERS FOR WHOM VIVA RAILINGS NOT RESPONSIBLE. THESE DRAWINGS ARE INTENDEDFOR FOR THE SOLE USE OF VIVA RAILINGS’ CUSTOMER AND THEIR AGENTS FOR THEAND INSTALLATION OF PRODUCTS FURNISHED BY VIVA RAILINGS. VIVA RAILINGS REMAINS THE SOLE OWNER OF ALL DESIGNS AND INTELLECTUAL PROPERTY USEDESIGN OF THESE DESIGNS FOR OTHER PURPOSE IS IS FORBIDDEN. SCALES ARE PROVIDED REFERENCE ONLY. FOR PRODUCT INFORMATION TECHNICAL SUPPORT, PLEASE CONTACT VIVA RAILINGS. CONTAINED WITHIN. REPRODUCTION AND USE OF THESE DESIGNS FOR ANY OTHER PURPOSE IS FORBIDDEN. SCALES ARE PROVIDED FOR REFERENCE ONLY. FOR PRODUCT INFORMATION AND TECHNICAL SUPPORT, PLEASE CONTACT VIVA RAILINGS.

151 W. Vista Ridge Mall Dr. Lewisville, TX 75067

972-353-8482

info@vivarailings.com

vivarailings.com

11


TM

V I V A

VIVA RAILINGS, LLC

BEACON RAILING SYSTEM

1454 HALSEY WAY, CARROLLTON, TX 75007

BEACON RAILING SYSTEM

P: 972-353-8482 F: 972-353-0013 e: info@vivarailings.com www.vivarailings.com

Page 4 of 4 12/4/2023

Illuminated Railing ILLUMINATED RAILING

30° ASYM. LINEAR

SYM. LINEAR

TOP RAIL

iRAIL Linear

SYM. POD

5" 316

36" TO FF

42" TO FF

ILLUMINATED HANDRAIL

iRAIL LINEAR ORIENTATION OPTIONS

22° ASYM. POD

1" Ø12

Illuminated Handrail Option

18" 24" OR 36"

Illuminated Toprail Option

POD

iRAIL POD ORIENTATION OPTIONS

iRAIL POD SPACING OPTIONS

See Viva iRail Railing System for more info

iRAIL LIGHTED RAILING SYSTEM 12

151 W. Vista Ridge Mall Dr. Lewisville, TX 75067

972-353-8482

info@vivarailings.com

vivarailings.com


BEACON GLASS RAILING SYSTEM

151 W. Vista Ridge Mall Dr. Lewisville, TX 75067

972-353-8482

info@vivarailings.com

vivarailings.com

13


BEACON GLASS RAILING SYSTEM AMERICAN AIRLINES HEADQUARTERS

AMERICAN AIRLINES HEADQUARTERS - FT. WORTH, TX General Contractor: StructureTone-Southwest Architect: Gensler

14

151 W. Vista Ridge Mall Dr. Lewisville, TX 75067

972-353-8482

info@vivarailings.com

vivarailings.com


BEACON GLASS RAILING SYSTEM AMERICAN AIRLINES HEADQUARTERS

AMERICAN AIRLINES HEADQUARTERS - FT. WORTH, TX General Contractor: StructureTone-Southwest Architect: Gensler

151 W. Vista Ridge Mall Dr. Lewisville, TX 75067

972-353-8482

info@vivarailings.com

vivarailings.com

15


NORTH AMERICA OPERATIONS

New York, NY Washington DC Kansas City, KS

151 W. Vista Ridge Mall Dr. Lewisville, TX 75067

San Diego, CA

Atlanta, GA

(Dallas/Fort Worth Metroplex)

Dallas/Fort Worth, TX

PH: 972.353.8482 | info@vivarailings.com vivarailings.com

Orlando, FL Regional Locations

Inc. Magazine 500 | 5000 VIVA RAILINGS, LLC. Among The Fastest Growing US Companies Eight Years in a Row 2012-2019

Inc. Magazine 500 | 5000 VIVA RAILINGS, LLC. Among The Fastest Growing Texas Companies #211

ICC-ES 4405 Certified

SHOE™ Structural Glass Railing System

LEED Material & Resources Credits 4.1 and 4.2

The American Institute of Architects

The California Contractors State License Board Certified

Version:120423


Turn static files into dynamic content formats.

Create a flipbook
BEACON Glass Product Data by viva.railings - Issuu