Page 1

AIRDISTRIBUTIONSYSTEM

TheuniqueFan-Jetisaspecialtubepressurizingfanwith curvedstationarydischargevanes(statorvanes)thatrecover therotationalenergyofdischargingairtoincrease performancecapacityandefficiency.

LOWCOST: Fan-Jetpowersmoreairatlesshorsepower forbestresultsatlowoperatingcosts.

QUALITY: Fan-Jetisfullyassembledatfactory,testrun andinspectedandthenshippedreadytoinstallwithbrackets andfasteners.

QUIET: Fan-Jet’slowsoneratingsareanAcmetradition.

DIRECTDRIVEMODELS -RC12,18

RCP12,18,24

Directdrivemodelsarecapableofvariablespeedcontrol. (SeeControlsonPage17)

BELTDRIVEMODELS -RC24,30;RCA24, 30

Beltdrivemodelsfeatureno-servicesealedfanshaftball bearingscapturedinauniquecastingtomaintainproper alignmentandspacing.

BUILTTOUGH: ThesteelmodelRCisavailablein12”, 18”,24”and30”sizesandisrustprotectedwithametalwash processandabaked-onfinish.AluminummodelRCAis availablein24”and30”sizesandproducedfromheavy gaugealuminum.TheRCPplasticmodelincorporatesABS plasticconstructionwithastainlesssteelframe.

HIGHPERFORMANCEPROPELLERS:

Thepropellersarematchedtothesize,performanceand constructionoftheFan-Jet.RCfanpropellersarewelded steelwithabakedonfinish.RCAfanpropellersarewelded heavygaugealuminum.RCP12fanbladesarepolycarbonate attachedtoaglassreinforcednylonhubwithanaluminum hubcore.RCP18-24bladesaremadeofstainlesssteel.

ModelsRCandRCParelistedbyCanadianStandards AssociationTestingLaboratoryasapproved.

ENERGYEFFICIENT: Allmotorsaretotallyenclosed, highefficiencydesignwithshieldedballbearingsandinclude thermaloverloadprotectiononsinglephasemodels.

FAN-JETPERFORMANCEDATA

Fan-Jet Model HPRPM Tube Size System CFM

▼ Motorized ShutterModel Heat Accessory

†RC12D4 1/8172512”1180/780WAAC1818NotAvailable

‡HeatingCapacityWithHeatKitBTU/hr.Output HeaterTemperatureRiseof 40°50°60°70°

NOTAPPLICABLE

RC18E6 1/4116018”3120WAAC2626HT18112,000138,000163,000186,000

RCA/RC24F 1/373524”5420WAAC3333HT24172,000212,000250,000287,000

RCA/RC30G ½60730”8550WAAC4040HT30278,000342,000403,000463,000

RCP12B4 1/10162512”1100WAAC1818NotAvailable

NOTAPPLICABLE

RCP18B4 1/10162518”2140WAAC2626PHT1877,00095,000112,000128,000

RCP18F4 1/3162518”3050WAAC2626PHT18109,000135,000159,000182,000

RCP24G6 ½107524”5115WAAC3333PHT24162,000200,000236,000271,000

†RC12D4hasa2-speedmotorthereforetwodifferentsystemCFM’s ▼ OrderCAMmotorizingkitsseparately.

‡TheOrderratingforgasfiredheatersis80%oftheirinputBTUratings.

Toll-free:

Website: www.usgr.com

10
ModelRCP ModelRCorRCA
US GLOBAL RESOURCES
+1-888-334-1440 | Ph: +1-830-755-4768
|
Email: usgr@usgr.com

TUBESELECTIONTABLE

TUBE MODEL TUBE LENGTH TUBE MODEL TUBE LENGTH TUBE MODEL TUBE LENGTH TUBE MODEL TUBE LENGTH

HFT10’-20’HFY18’-20’HKX24’-27’HKT39’-42’

HLT20’-25’HDY20’-22’HJX27’-30’HJT42’-47’

HRT25’-30’HCY22’-25’HHX30’-33’HHT47’-52’

HLW30’-35’HBY25’-27’HFX33’-37’HFT52’-58’

HMW35’-40’HKN27’-30’HDX37’-41’HDT58’-66’

HLY40’-50’HJN30’-33’HCX41’-45’HCT66’-77’

HRY50’-60’HHN33’-36’HBX45’-48’HKS77’-84’

HMZ60’-75’HFN36’-40’HKP48’-53’HJS84’-94’

HRZ75’-100’HDN40’-45’HJP53’-59’HHS94’-104’

HCN45’-50HHP59’-66’HFS104’-116’

HBN50’-55’HFP66’-73’HDS116’-129’

HKA55’-61’HDP73’-81’HCS129’-145’

HJA61’-68’HCP81’-90’HBS145’-163’

HHA68’-76’HBP90’-101’HKU163’-183’

HFA76’-85’HKI101’-112’HJU183’-206’

HDA85’-96’HJI112’-126’ **HHU206’-232’

HCA96’-108’HHI 126’-142’HFU232’-263’

*HBA108’-121’HFI142’-160’ *HDU263’-305’

**HKE 121’-138’ **HDI 161’-182’HCU305’-348’

HJE138’-154’ *HCI 182’-206’HBU348’-405’

HHE154’-177’HBI206’-233’

HFE177’-205’HKO233’-269’

HJO269’-311’

HHO311’-360’

*MaximumtubelengthforFreshAirConvectionTubeSystem.

**MaximumtubelengthforFan-JetwithHeatKit.

+When12”tubingisusedforPerimeterHeatingtheTubeModelisprefixedbytheletterP.

HEATKITS foroverheadheating

CAUTION! Toavoidcombustionmalfunctionswhentwoheatersareused withoneFan-Jet;theminimumheaterdistancefromFan-Jetopeningmust bemaintained,bothheatersmustoperatesimultaneouslyunlesscenter baffleisused,andthedischargelouversmustbedirectedtowardthetopof theFan-Jetopening.

WEATHERHOOD:

Galvanizedsteel,withbird screen.Flangesfitmotorized shutterframesforeasy installation.

POLYETHYLENETUBING

Alltubesareengineeredforuniformdistributionandproper mixingofairtoproducethebestaerodynamiceffectin greenhousestructures.

• Furnishedinclear4milthickUVstabilizedpolyethylene material.

• Eachtubeiscustompunchedtomatchtheselected Fan-JetUnitwitheachspecifichouse.Sincetubesare custompunched,ordersalreadyprocessedorshipped cannotbecancelledorreturnedforcredit.

TUBEHANGERSET

Uniquehangerclampsontotubingfor easyattachmenttooverheadsupportwire withsnapring.

RECOMMENDED SPACING

12”Tubingevery10ft. 18”Tubingevery10ft. 24”Tubingevery8ft. 30”Tubingevery6ft.

Wiresupportkits,availablein50’,100’,150’,200’and300’lengths,include sixstrand10gaugewire,turnbuckleand2securingclips.

*CAUTION! Thistubing,foruseingreenhouses,doesnotcontain fireretardants.Duecareshouldbetakenduringinstallationand operationtokeepawayfromopenflame.

AcmeHeatKitsallowuseofgasfired,electric,steamorhotwater unitheaterswithoutoutsideairpassingthroughtheheatexchanger. WhenusedwithFan-Jet,HeatKitskeepcoilsandelementsoutofthe airflowroute,thussavingenergy.Eachkitconsistsoftwobaffle plateswithairscoopsattachedhorizontallytothetopandbottomof theFan-JetUnitandtotheframedopeningofthemotorizedinlet shutter.KitsalsocomewithaFan-Jetmotorshieldtopreventheat build-up.Acenterbaffleaccessoryisincludedforusewhenopposing heaterstriggerseparately,preventingblow-throughofhotairand possiblemotordamage.

*Theunitheaterlouversshouldbeatthesameelevationasthe Fan-Jetinletopeningandspacedaproperdistancefromit,withthe axisoftheunitheaterdischargeopeningdirectedtowardtheFan-Jet inletopening.Iftheheatermustbepositionedbelowthelevelofthe Fan-Jetinletopeningtomaintaintheproperspacing,thelouvers shouldbeadjustedtodirecttheheatedairupwardtowardthetopof theinletopening.

IftheFan-Jetendofthebuildingiscolderthantheremainderofthe house,thisconditionusuallycanbecorrectedbyadjustingoneortwo ofthelowerlouversoftheheaterstoadownwardpositiontodivert partoftheheatedairtotheendwallarea.

CAUTION! Guardsarestronglyrecommendedwhenthefanis installedwithinseven(7)feetofthefloor,workinglevelorwithin reachofpersonnel.GuardscomplyingwithOSHAregulationsare availableasoptionalequipment.ReviewOSHACodesandobtain aquotation.

12” FAN-JET 18”FAN-JET or 18”INLET 24”FAN-JET or 24”INLET 30”FAN-JET or 30”INLET
ModelsRCandRCParelistedbytheCanadian StandardsAssociationTestingLaboratoriesas approved.
WEATHER HOOD MODEL DIMENSIONS WEIGHT ABC RH12 18” 18” 16” 20 RH18 26” 26” 24” 35 RH24 33” 33 30” 55 RH30 40” 40” 37” 75
11 US GLOBAL RESOURCES Toll-free: +1-888-334-1440 | Ph: +1-830-755-4768 Website: www.usgr.com | Email: usgr@usgr.com