Pinon Residence - New Bathroom Addition Plans - 20814 N. 30TH Dr. - Phoenix, AZ

Page 1


EXCEPTTHATSLABSONGRADENEEDBEVIBRATEDONLYAROUND-UNDERFLOORDUCTS,ETC. MAXIMUMSLUMP4-1/2"FORCONCRETEWITHOUTPLASTICIZER.IFPLASTICIZERISUSED,AHIGHER FINALSLUMPMAYBEALLOWEDUPONSTRUCTURALENGINEER'SAPPROVAL.CASTCLOSUREPOUR AROUNDCOLUMNSAFTERCOLUMNDEADLOADISAPPLIED.UNLESSAPPROVEDOTHERWISEIN WRITINGBYTHEDESIGNER,ALLCONCRETESLABSONGRADESHALLBEBOUNDBYCONTROLJOINTS (KEYEDORSAWCUT),ASSHOWNONTHEFOUNDATIONPLANSUCHTHATTHEENCLOSEDAREADOES NOTEXCEED400SQUAREFEET.KEYEDCONTROLJOINTSNEEDONLYOCCURATEXPOSEDEDGES DURINGPOURING.ALLOTHERJOINTSMAYBESAWCUT. #5INCENTEROFGROUTATCENTEROFWALL,CONTINUOUSFULLHEIGHTOFWALLATALL CORNERS,INTERSECTIONS,WALLENDS,BEAMBEARINGS,EACHSIDEOFCONTROLJOINTSANDAT INTERVALSNOTTOEXCEED48"O.C.UNLESSNOTEDOTHERWISESEESCHEDULE.TIEAT8'-0" VERTICALLY,WITHSINGLEWIRELOOPTIEBYA.A.WIREPRODUCTSCOMPANY.LAPSPLICESSHALLBE 48BARDIAMETERSFORGRADE60BARS.DOWELALLVERTICALREINFORCINGTOFOUNDATIONWITH DOWELSTOMATCHVERTICALREINFORCING.

2#5INMINIMUM8"DEEPGROUTEDCONTINUOUSBONDBEAMATROOFLINE.#5INMINIMUM8"DEEP GROUTEDCONTINUOUSBONDBEAMATTOPOFPARAPETORTOPOFAFREESTANDINGWALL.PLACE THESEBARSCONTINUOUSTHROUGHCONTROLJOINTSPERTYPICALDETAIL.PROVIDEBENTBARS PERTYPICALDETAILS,TOMATCHHORIZONTALBONDBEAMREINFORCING,ATCORNERSANDWALL INTERSECTIONTOMAINTAINBONDBEAMCONTINUITY.LAPSPLICESSHALLBE40BARDIAMETERS FORGRADE40BARSAND48BARDIAMETERSFORGRADE60BARS.STAGGERSPLICESAMINIMUMOF 40BARDIAMETERS.DONOTSPLICEWITHIN8'-0"OFCONTROLJOINTS.STANDARDWEIGHT(NO. GAGEWIRE)DUR-O-WALORDUR-O-WIRE(OREQUIVALENT)LADDERTYPEJOINTREINFORCEMENTAT 16"O.C.INMASONRYWALLSLAP8"MINIMUM.

UNLESSNOTEDOTHERWISEORSHOWN,PROVIDELINTELSIN8"MASONRYWALLSPERTYPICAL NON-BEARINGLINTELDETAILFOROPENINGSREQUIREDBYOTHERDISCIPLINES(MECHANICAL, ELECTRICAL,PLUMBING,ETC.). ALLREINFORCINGPERCRSISPECIFICATIONSANDHANDBOOK.ASTMA615(Fy60KSI)DEFORMED BARSFORALLBARS#5ANDLARGER(ANDFORALLCONCRETEWALLS,BEAMS,SLABSANDCOLUMN REINFORCEMENT.ASTMA615(Fy40KSI)DEFORMEDBARSFORALLBARS#4ANDSMALLER.ALL GRADE60REINFORCINGTOBEWELDEDSHALLBEASTMA706.WELDEDWIREFABRICPERASTMA185, WIREPERASTMA82.NOTACKWELDINGOFREINFORCINGBARSALLOWEDWITHOUTPRIORREVIEW OFPROCEDUREWITHTHEDESIGNER.LATESTACICODEANDDETAILINGMANUALAPPLY #6ORLARGER...........................................................2" #5ORSMALLER.........................................................1-1/2"

GENERALSTRUCTURALSPECIFICATIONS

LUMBER(SAWNLUMBER)

FRAMINGLUMBERSHALLCOMPLYWITHTHELATESTEDITIONOFTHE GRADINGRULESOFTHEWESTERNWOODPRODUCTSASSOCIATION ORTHEWESTCOASTLUMBERINSPECTIONBUREAU.ALLSAWN

LUMBERSHALLBESTAMPEDWITHTHEGRADEMARKOFAN APPROVEDLUMBERGRADINGAGENCYANDSHALLHAVETHE

FOLLOWINGMINIMUMPROPERTIES:

PROVIDEBENTCORNERBARSTOMATCHANDLAPWITHHORIZONTALBARSATALLCORNERSAND INTERSECTIONSPERTYPICALDETAILS.REINFORCINGBARSPACINGGIVENAREMAXIMUMON CENTERS.ALLBARSPERCRSISPECIFICATIONSANDHANDBOOK.DOWELALLVERTICAL REINFORCINGTOFOUNDATIONWITHSTANDARD90DEGREEHOOKSUNLESSNOTEDOTHERWISE. SECURELYTIEALLBARSINLOCATIONBEFOREPLACINGCONCRETE.

SHEATHING ALLPLYWOODSHALLBECDXORBETTERANDSHALLBEARTHE STAMPOFANAPPROVEDTESTINGAGENCY.LAYUPPLYWOODWITH FACEGRAINPERPENDICULARTOSUPPORTS.STAGGERJOINTS.ALL NAILINGCOMMONNAILS.ALLPLYWOODSHALLBEOFTHE FOLLOWINGTHICKNESS,SPAN/INDEXRATIO,ANDSHALLBE ATTACHEDASFOLLOWSUNLESSOTHERWISENOTEDONPLANS.

SPAN/INDEX EDGE FIELD USE THICKNESSRATIOATTACHMENTATTACHMENT ROOF1/2 32/16 8d@6"O.C. 8d@12"O.C. ROOF5/8 32/16 10d@6"O.C. 10d@12"O.C. FLOOR3/4T&G40/20 SCREWS@6"O.C.SCREWS@12" O.C. WALL3/8 24/0 8d@6"O.C. 8d@12"O.C.

GLUE-LAMINATEDBEAMS

GLUED-LAMINATEDBEAMSSHALLHAVETHEFOLLOWINGMINIMUM PROPERTIES: Fb=2,400PSI,Fv=165PSI,Fc(PERP)=650PSI.E=1,800,000PSI. BEAMSCANTILEVERINGOVERSUPPORTSSHALLHAVETHE SPECIFIEDMIN.PROPERTIESTOP&BOTTOM.ALLBEAMSSHALLBE FABRICATEDUSINGWATERPROOFGLUE.FABRICATION&HANDLING PERLATESTAITCANDWCLASTANDARDS.BEAMSTOBEARGRADE STAMPANDAITCSTAMPANDCERTIFICATE.U.N.O.ONPLANS, CAMBERSHALLBEBASEON3500FT.RADIUS.

LUMBERNOTES&SPECIFICATIONS

THESCOPEOFTHISPROJECTISTODESIGN&BUILD2NEWADDITIONAL BATHROOMS,ANADUSPACEANDREMODELONEOFTHEBEDROOMS INTOAGAMEROOMINSIDETHEEXISTINGRESIDENTIALHOME.

SCOPEOFWORK

THEPHOENIXBUILDINGCONSTRUCTIONCODECONSISTSOFTHECITY OFPHOENIXADMINISTRATIVEPROVISIONS,THEFOLLOWINGCODES ANDSTANDARDS,ANDCITYOFPHOENIXAMENDMENTSTHERETO:

2023INTERNATIONALBUILDINGCODE(IBC)

2023INTERNATIONALRESIDENTIALCODE(IRC)

2023INTERNATIONALEXISTINGBUILDINGCODE(IEBC) 2023INTERNATIONALENERGYCONSERVATIONCODE(IECC) 2023INTERNATIONALMECHANICALCODE(IMC) 2023INTERNATIONALFUELGASCODE 2023INTERNATIONALCODECOUNCILPERFORMANCECODE 2021NATIONALELECTRICALCODENFPA-70 2023INTERNATIONALPLUMBINGCODE(IPC)

CODES

1.DEVELOPMENTANDUSEOFTHISSITEWILLCONFORMTOALLAPPLICABLE CODESANDORDINANCES.

2.ALLNEWORRELOCATEDUTILITIESWILLBEPLACEDUNDERGROUND.

3.STRUCTURESANDLANDSCAPINGWITHINATRIANGLEMEASUREDBACK10 FEETFROMTHEPROPERTYLINEAND20FEETALONGTHEPROPERTYLINEON EACHSIDEOFTHEDRIVEWAYENTRANCESWILLBEMAINTAINEDATAMAXIMUM HEIGHTOF3'-0".

4.OWNERSOFPROPERTYADJACENTTOPUBLICRIGHTOFWAYWILLHAVETHE RESPONSIBILITYFORMAINTAININGALLLANDSCAPINGWITHINTHERIGHTOF WAYINACCORDANCEWITHAPPROVEDPLANS.

4.ANYLIGHTINGWILLBEPLACEDSOASTODIRECTTHELIGHTAWAYFROM ADJACENTRESIDENTIALDISTRICTSANDWILLNOTEXCEEDONEFOOTCANDLE ATTHEPROPERTYLINE.NONOISE,ODORORVIBRATIONWILLBEEMITTEDAT ANYLEVELEXCEEDINGTHEGENERALLEVELOFNOISE,ODORORVIBRATION EMITTEDBYUSESINTHEAREAOUTSIDEOFTHESITE.

6.ALLROOFTOPEQUIPMENTANDSATELLITEDISHESSHALLBESCREENEDTO THEHEIGHTOFTHETALLESTEQUIPMENT.

7.ALLSERVICEAREASSHALLBESCREENEDTOCONCEALTRASHCONTAINERS, LOADINGDOCKS,TRANSFORMERS,BACKFLOWPREVENTOR,ANDOTHER MECHANICALORELECTRICALEQUIPMENTFROMEYELEVELADJACENTTOALL PUBLICSTREETS.

8.THEEXISTINGSTRUCTURESMUSTCOMPLYWITHTHECHANGEOF OCCUPANCYPROVISIONSINTHEPHOENIXCONSTRUCTIONCODEPRIORTO USE.

9.AFTERFINALAPPROVALTHEPROJECTWILLBEINSPECTEDFORZONING COMPLIANCEDURINGCONSTRUCTIONANDPRIORTOOCCUPANCY.THE APPLICANTISTONOTIFYDSDPRIORTOOCCUPANCYTOARRANGEFOR INSPECTIONS.CALL262-6981ANDREQUESTADESIGNREVIEWINSPECTION.

10.BARBED,RAZORORCONCERTINAWIRE(ORSIMILAR)SHALLNOTBEUSED ONTHISSITEWHEREVISIBLEFROMPUBLICSTREETSORADJACENT RESIDENTIALAREAS.

11.ONSITELIGHTINGSHALLNOTEXCEEDONEFC(FOOTCANDLE)ATTHE PROPERTYLINE.

12.MAXIMUMNOISELEVELOF55DECIBELS(NORMALSPEAKINGVOICE)ATTHE PROPERTYLINE.

13.SITELANDSCAPING,WALLSANDLIGHTINGTOMATCHINPHASEDPROJECTS.

14.ALLON-SITEWATERLINES,INCLUDINGTHOSEREQUIREDFORFIRE PROTECTIONSHALLBEPRIVATEPLUMBINGLINESSUBJECTTOTHEPHOENIX PLUMBINGCODE.

15.THEARCHITECTSHALLNOTHAVECONTROLORCHARGEOF,ANDSHALLNOT BERESPONSIBLEFORCONSTRUCTIONMEANS,METHODS,TECHNIQUES, SEQUENCEONPROCEDURES,ORFORSAFETYPRECAUTIONSANDPROGRAMS INCONNECTIONWITHTHEWORK,ALLOFWHICHSHALLBETHESOLE RESPONSIBILITYOFTHECONTRACTOR.

16.THEDESIGN,ADEQUACY,ANDSAFETYOFERECTIONBRACING,SHORING, TEMPORARYSUPPORTS,ETC.,DURINGDEMOLITIONANDCONSTRUCTION,IS THESOLERESPONSIBILITYOFTHECONTRACTOR,ANDHASNOTBEEN CONSIDEREDBYTHESTRUCTURALENGINEER.

17.DISCREPANCIESINTHECONTRACTDOCUMENTS;INTHEEVENTOFERROR, OMISSION,AMBIGUITY,ORCONFLICTWITHINTHEDRAWINGSOR SPECIFICATIONS,THECONTRACTORSHALLBRINGTHEMATTERTOTHE ARCHITECT'SATTENTIONINATIMELYMANNER,FORARCHITECT'S DETERMINATIONANDDIRECTIONINACCORDANCEWITHPROVISIONSOFTHE GENERALCONDITIONS.DISCREPANCIESINTHECONTRACTDOCUMENTSSHALL NOTBEALLOWEDASABASISFORCHANGEORDERS.

18.JOBSITEMEASUREMENTSARETHEFULLRESPONSIBILITYOFTHE CONTRACTORAND/ORSUBCONTRACTORANDMUSTBETAKENFORALLITEMS BYALLSUBCONTRACTORSPRIORTOFABRICATION.

19.THECONTRACTORSHALLBERESPONSIBLEFORINSTALLINGSOLIDBACKING BEHINDALLSHELVING,HANDRAILS,BRACKETS,CABINETS,DOORSTOPSETC. ANDALLEQUIPMENTREQUIRINGBACKING.

20.WRITTENDIMENSIONSHALLBEUSEDFORLAY-OUT.DONOTSCALE DRAWINGS.

21.THECONTRACTORSHALLVISITTHEJOBSITEANDBERESPONSIBLEFOR THETHEVERIFICATIONOFALLEXISTINGCONDITIONS,ELEVATIONSAND DIMENSIONSPRIORTOCOMMENCINGCONSTRUCTION.

22.THECONTRACTORSHALLBERESPONSIBLEFORLEAVINGALLFINISHED SURFACESCLEANATTHECOMPLETIONOFTHEWORKANDSHALLREMOVEALL EXCESSMATERIALANDDEBRISFROMTHEJOBREGULARLY.

23.ALLCONSTRUCTIONANDWORKMANSHIPSHALLCONFORMTOTHE REQUIREMENTSOFLOCALCODES.

24.RELATIONSHIPOFCONTRACTDOCUMENTS:DRAWINGS,SPECIFICATIONS ANDOTHERCONTRACTDOCUMENTSINTHEPROJECTMANUALAREINTENDED TOBECOMPLIMENTARY.WHATISSHOWNORREQUIREDBYONESHALLBEASIF REQUIREDBYALL.WHATISSHOWNORREQUIRED,ORMAYBEREASONABLY INFERREDTOBEREQUIRED,ORWHICHISUSUALLYANDCUSTOMARILY PROVIDED,SHALLBEINCLUDEDINTHEWORK.

25.THECONTRACTORSHALLCOORDINATETHEINSTALLATIONOFALLITEMS MARKEDO.F.C.I.(OWNERFURNISHED/CONTRACTORINSTALLEDORN.I.C.ITEMS (NOTINCONTRACT)WITHTHEOWNER.

26.THECONTRACTORSHALLBERESPONSIBLEFOROBTAININGTHEFOLLOWING PERMITSINADDITIONTOTHEOTHERPERMITSREQUIRED:

EXIST'G.AREA=6,957S.F. EXIST'GLIVABLESPACE=1,508S.F. ***TOTALADDITIONALSPACE=112S.F. -NEWBATHROOM1=40S.F. -NEWBATHROOM2=38S.F. NEWPORCH=23S.F. -NEWWATER/HEATER=11S.F. TOTAL=112S.F.

TOTALLIVABLESPACEAREA=1,620S.F. TOTALUNDERROOFAREA=2,430S.F. LOTCOVERAGE=1,620/6,957=23.28%

W.McDOWELLRD. I-10
W.THOMASRD.
W.INDIANSCHOOLRD.

N. 30TH DR.

20814

20814 N. 30TH DR.

NOTE EXTENDEXISTINGROOF,WHICHISADDED WITHPEEL&STICKMATERIALFORFLAT ROOFSBSSELF-ADHERINGBASESHEET ROLLFORLOWSLOPEROOF.

NOTE EXTENDEXISTINGROOF,WHICHISADDED WITHPEEL&STICKMATERIALFORFLAT ROOFSBSSELF-ADHERINGBASESHEET ROLLFORLOWSLOPEROOF.

ROOFVENT

AIRVENTILATIONFOR DRAINAGEPIPE

NEWBATHROOM

NORTHELEVATION

ROOFVENT

AIRVENTILATIONFOR DRAINAGEPIPE

NEWWATER HEATERROOM

ROOFVENT

AIRVENTILATIONFOR DRAINAGEPIPE

NEWBATHROOM

NEWBATHROOM

STUCCOFIN. IAPMO32(TYP.)
STUCCOFIN.
STUCCOFIN.

EXTERIOROR INTERIORWALLS

TREATEDPLATEAND

2XxBEARINGWALL

SLOPETODRAIN

1/4"12"MAX 1/8"12"MIN.

3" MIN.

FTG.@DOOR

2X4FLATAT24"O.C.NOTCH ENDTRUSSTOPASSTHRU& SUPPORTFASCIA

8dNAILS@6"OC

2x8 FASCIA

2x4BLKG.@48" OC 4-16d

2-16dEA. END

A35FRAMING ANCHOREACH SIDEOFSTUDS

PRE-FAB. TRUSSES DBL.2X6 CONT.TOP PLATE

2X6@16" O.C.MAX W/R-19 INSULATION

WALL(WHERE OCCURS)

MINIMUM(2)#4REBAR TOP&BOTTOMOFNEW FOOTING NEWCONC.

EXISTINGCONC. SLAB&FOOTING

WALL (WHEREOCCURS)

EXISTING4" CONC.SLAB &FOOTING

NEW4"CONC. SLABO/4" A.B.C.FILL

#4REBAREPOXIED6"

DOWELL@NEWFTNG.

ROOF SHINGLES

DOWELL@NEWSLAB

EXT.STUCCOFINISH

1/2"GYP.BD.FINISHINSIDE

2X6STUDS@24"O.C.W/R-19 INSULATION

2XHEADERSEEFRAMING PLAN

SEEFRAMINGPLANFORSIZE

CAULKSEALANTBOTHSIDES

R-38 INSULATION 2x FASCIA

10x10 WOOD COLUMN

5/8"GYPBD@ CEILING

SHOWERRECEPTORSBUILTDIRECTLYON THEGROUNDSHALL:

A)BEWATERTIGHT

B)BECONSTRUCTEDOFAPPROVEDTYPE,DENSE, NON-ABSORBENTANDNON-CORROSIVEMATERIALS

C)BEADEQUATELYREINFORCED

D)BEPROVIDEDWITHANAPPROVEDFLANGEDFLOOR DRAINMADEOFCASTIRONORBRASSDESIGNEDTO MAKEWATERTIGHTJOINTINFLOOR

E)HAVESMOOTH,IMPERVIOUSANDDURABLE SURFACES

F)HAVECURBSEXTENDINGATLEAST3"ABOVETHE FINISHEDTHRESHOLDBEFOREANYWOODSTRUCTURE MAYBEADDED

ROOF&WALLDETAIL

VAPOR BARRIER

2XSTUD FRAM'G

R-19BATTS(OR INSUL.)

1/2"GYPBD

1"T&GFIRERESISTIVEFOAM BOARD

WIREFABRICLATH MIN.#20GAUGE1"GALV. STEELWOVEN-WIREFABRIC.

INTERIOR FLOOR

REINFORCINGSTEEL

ONEKOTESTUCCOIAPMO ES382O/ VAPORBARRIER

1/2"∅A.B.@48"O.C.7" MIN.EMBED&12"FROM PLATEENDS.W/2" WASHER

1/2"GYP.BD.

R-19INSULATION

2X6STUDS@16"O.C.

H2.5@32"O.C.

4"CONC.O/ 4"A.B.C.

NAT.GRADE

2-#4CONT

#4BENTBAR@ 36"O.C.

WINDOWFRAME,FINISHAND STYLEBYOWNER

LINEOFWALLBEYOND

WINDOWHEADER

NOTE:

WEATHERRESISTIVE BARRIERISREQUIRED BEHINDFOAMPLASTIC SUBSTRATES&OVEROTHER SUBSTRATES. TWOLAYERSOFGRADE"D" WEATHERRESISTIVE BARRIER;BUILDINGPAPER APPLIEDDIRECTLYTO EXTERIORSIDEOFSTUD FRAMING.STAGGERJOINTS, LAPPEDHORIZ.6"MIN., VERTICAL2"MIN.

STUCCO,PERKWIK-KOTE MFR'SSPECS.ASTMC1328-05

NOTE:MIN.0.021"(NO.26GAUGE) CORROSION-RESISTANTWEEPSCREEDWITHA MIN.VERT.ATTACHMENTFLANGEOF1/2".

WALLCOVERINGIAPMO-ES382)STANDARDTYPICALDETAIL

EXTERIORSTUCCO

TYP.EXT.CORNER

PROVIDEDBL. STUDWHERE HOLDOWN OCCURS.

TYP.INT.INTERSECTION

TOOLEDEDGES TYPICAL F.G. (1)#4BAR BASEMATERIAL.

4"CONCRETESLAB O/4"ABCFILL

TOOLEDEDGES TYPICAL 4"CONCRETESLAB O/4"ABCFILL 1/2"EXP.JNT.

HOLD-DOWNSEE SHEARWALLSCHEDULE.

DOUBLESTUDS.

EXT.CORNERW/HOLDOWN

NAILPERG.S.N. ANDSHEARWALL SCHEDULE.

TYP.INT.CORNER

HOLD-DOWNASSPECIFIED ONFOUNDATIONPLAN.

INTERSECTIONATS.W.END

INTERSECTIONATS.W.HOLDOWN

TYPICALCORNERDETAILS