3. OWNERS OF PROPERTY ADJACENT TO PUBLIC RIGHT OF WAY WILL HAVE THE RESPONSIBILITY FOR MAINTAINING ALL LANDSCAPING WITHIN THE RIGHT OF WAY IN ACCORDANCE WITH APPROVED PLANS. 4. ANY LIGHTING WILL BE PLACED SO AS TO DIRECT THE LIGHT AWAY FROM ADJACENT RESIDENTIAL DISTRICTS AND WILL NOT EXCEED ONE FOOT CANDLE AT THE PROPERTY LINE. NO NOISE, ODOR OR VIBRATION WILL BE EMITTED AT ANY LEVEL EXCEEDING THE GENERAL LEVEL OF NOISE, ODOR OR VIBRATION EMITTED BY USES IN THE AREA OUTSIDE OF THE SITE. 5. IF A CHANGE OF OCCUPANCY OCCURS THE EXISTING STRUCTURES MUST COMPLY WITH THE CHANGE OF OCCUPANCY PROVISIONS IN THE MISSISSIPPI CONSTRUCTION CODE PRIOR TO USE.
CODES 48 DEVON RD. JAYESS MS 39641
PARCEL USE CODE:
6400
COUNTY-PROVIDED ACRES:
0.48772
CENTROID COORDINATES:
31.234462, -90.447359
FEDERAL QUALIFIED OPPORTUNITY ZONE:
NO
CENSUS 2020 BLOCKGROUP: CENSUS 2020 TRACT:
281139503005 28113950300
12. JOB SITE MEASUREMENTS ARE THE FULL RESPONSIBILITY OF THE CONTRACTOR AND/OR SUBCONTRACTOR AND MUST BE TAKEN FOR ALL ITEMS BY ALL SUBCONTRACTORS PRIOR TO FABRICATION.
16. THE CONTRACTOR SHALL BE RESPONSIBLE FOR LEAVING ALL FINISHED SURFACES CLEAN AT THE COMPLETION OF THE WORK AND SHALL REMOVE ALL EXCESS MATERIAL AND DEBRIS FROM THE JOB REGULARLY. 17. ALL CONSTRUCTION AND WORKMANSHIP SHALL CONFORM TO THE REQUIREMENTS OF LOCAL CODES. 18. RELATIONSHIP OF CONTRACT DOCUMENTS: DRAWINGS, SPECIFICATIONS AND OTHER CONTRACT DOCUMENTS IN THE PROJECT MANUAL ARE INTENDED TO BE COMPLIMENTARY. WHAT IS SHOWN OR REQUIRED BY ONE SHALL BE AS IF REQUIRED BY ALL. WHAT IS SHOWN OR REQUIRED, OR MAY BE REASONABLY INFERRED TO BE REQUIRED, OR WHICH IS USUALLY AND CUSTOMARILY PROVIDED, SHALL BE INCLUDED IN THE WORK.
GENERAL NOTES
SHEET INDEX S. MAGNOLIA ST.
MAILING ADDRESS: MAILING ADDRESS CITY: MAILING ADDRESS STATE: MAILING ADDRESS ZIP:
7. MAXIMUM NOISE LEVEL OF 55 DECIBELS (NORMAL SPEAKING VOICE) AT THE PROPERTY LINE..
11. DISCREPANCIES IN THE CONTRACT DOCUMENTS; IN THE EVENT OF ERROR, OMISSION, AMBIGUITY, OR CONFLICT WITHIN THE DRAWINGS OR SPECIFICATIONS, THE CONTRACTOR SHALL BRING THE MATTER TO THE ARCHITECT'S ATTENTION IN A TIMELY MANNER, FOR ARCHITECT'S DETERMINATION AND DIRECTION IN ACCORDANCE WITH PROVISIONS OF THE GENERAL CONDITIONS. DISCREPANCIES IN THE CONTRACT DOCUMENTS SHALL NOT BE ALLOWED AS A BASIS FOR CHANGE ORDERS.
15. THE CONTRACTOR SHALL VISIT THE JOB SITE AND BE RESPONSIBLE FOR THE THE VERIFICATION OF ALL EXISTING CONDITIONS, ELEVATIONS AND DIMENSIONS PRIOR TO COMMENCING CONSTRUCTION.
SITE . . . . . EXISTING SITE PLAN & DATA INFORMATION A101 . . . . .EXISTING FOOTPRINT ON SITE A102 . . . . .EXISTING FLOOR PLAN ON SITE A103 . . . . .EXISTING FLOOR PLAN A104 . . . . .NEW FLOOR PLAN ON SITE A105 . . . . .SHADED RESTRICTED AREAS IN BUILDING A106. . . . . NEW FLOOR PLAN A107 . . . . NEW FLOOR PLAN (DETAIL) A108. . . . . FLOOR CUT PLAN E101. . . . . ELECTRICAL PLAN (POWER & AUXILIARY) E102. . . . . REFLECTIVE CEILING PLAN (LUMINAIRES) E103. . . . . REFLECTIVE CEILING PLAN (UNITRUST) R101. . . . . ROOF PLAN R102. . . . . STRUCTURAL FLOOR PLAN P101. . . . . PLUMBING PLAN - P101 P102. . . . . PLUMBING PLAN - P102 M101. . . . . MECHANICAL PLAN S101. . . . . SECURITY PLAN S102. . . . . SOUTH & WEST ELEVATION S103. . . . . NORTH & EAST ELEVATION S104. . . . . SECTIONS A & B S105. . . . . SECTION C N101. . . . . INFORMATION NOTES
AY ST OADW
SMITH, JOHNNY
10. THE DESIGN, ADEQUACY, AND SAFETY OF ERECTION BRACING, SHORING, TEMPORARY SUPPORTS, ETC., DURING DEMOLITION AND CONSTRUCTION, IS THE SOLE RESPONSIBILITY OF THE CONTRACTOR, AND HAS NOT BEEN CONSIDERED BY THE STRUCTURAL ENGINEER.
14. WRITTEN DIMENSION SHALL BE USED FOR LAY-OUT. DO NOT SCALE DRAWINGS.
20. THE CONTRACTOR SHALL BE RESPONSIBLE FOR OBTAINING THE FOLLOWING PERMITS IN ADDITION TO THE OTHER PERMITS REQUIRED: A. BUILDING PERMIT B. STRUCTURAL PERMIT C. FIRE ALARM SYSTEM
S. BR
OWNER NAME:
6. ON SITE LIGHTING SHALL NOT EXCEED ONE FC (FOOT CANDLE) AT THE PROPERTY LINE.
9.THE ARCHITECT SHALL NOT HAVE CONTROL OR CHARGE OF, AND SHALL NOT BE RESPONSIBLE FOR CONSTRUCTION MEANS, METHODS, TECHNIQUES, SEQUENCE ON PROCEDURES, OR FOR SAFETY PRECAUTIONS AND PROGRAMS IN CONNECTION WITH THE WORK, ALL OF WHICH SHALL BE THE SOLE RESPONSIBILITY OF THE CONTRACTOR.
13. THE CONTRACTOR SHALL BE RESPONSIBLE FOR INSTALLING SOLID BACKING BEHIND ALL SHELVING, HANDRAILS, BRACKETS, CABINETS, DOOR STOPS ETC. AND ALL EQUIPMENT REQUIRING BACKING.
BEECH ST.
SITE
.
LEGAL DESCRIPTION:
TCT IN SE1/4SE1/4 ZN:AE-28113C0102C
PAGE: SUBDIVISION:
301057 EAST MCCOMB SECTION 12-3-7
LASALLE ST.
0.48788 CALCULATED ACRES: CALCULATED PARCEL SQ. FT: 21,252
CL
VOGEL ST.
D.
SLE
E . PR
E
CULTIVATED VALUE 1: CULTIVATED VALUE 2:
19566 0
UNCULTIVATED VALUE 1: UNCULTIVATED VALUE 2:
0 0
IMPROVEMENT VALUE 1: IMPROVEMENT VALUE 2:
8610 53930
CULTIVATED ACRES 1: CULTIVATED ACRES 2:
0 0
UNCULTIVATED ACRES 1: UNCULTIVATED ACRES 2:
0 0
TOTAL ASSESSED VALUE:
12317
TAX DISTRICT:
131
EXEMPT CODE: USE CODE 2: DEED DATE:
0 9100 2019-12-19
ALTERNATE PARCEL NO:
73C12-4-062-P
DATA
A.P.N. 501393R
VICINITY MAP
EXIST'G. DIRT DRIVEWAY
EXIST'G. BUILDING 4770 S.F.
CONCRETE PARKING LOT
STRUCTURES AND LANDSCAPING, WITHIN A TRIANGLE MEASURING 33'X 33' ALONG THE PROPERTY LINE WILL BE MAINTAIN AT A MAXIMUM HEIGHT OF 3'-0".
906 S. MAGNOLIA ST. 501393R 28,867
APPRAISED AC: TOWNSHIP: RANGE: TR SECTION: PROP. STREET: PROP ADD NUM: DEED BOOK DEED PAGE LEGAL DESCRIPTION:
64.21 3 7 12 RAILROAD BLVD. S. 0 246 242 ICRR LANDS IN SEC 12-3-7 E MCCOMB ZN:AE-X0.2-X-28113C0102C LIGHT INDUSTRIAL (I-1)
LOT COVERAGE: EXIST'G. AREA= TOTAL UNDER ROOF AREA= LOT COVERAGE =
4,770 S.F. 4,770 S.F. 21.92%
PARKING REQUIRED: 1 SPACE PER 1,000 G.S.F.= 4,600/1,000 = 4.31 SPACES 1 SPACE PER 350 G.S.F. OFFICE= 462/350 = 1.32 SPACES
BARBED WIRE FENCE
TOTAL REQUIRED=
5.63 SPACES
PARKING SUMMARY:
STRUCTURES AND LANDSCAPING AT THE INTERSECTION OF PUBLIC STREETS AND PRIVATE ACCESS WAYS, WITHIN A TRIANGLE MEASURING 33'ALONG THE PUBLIC STREET AND 15' ALONG THE PRIVATE ACCESS WAY RIGHT OF WAY LINES, WILL BE MAINTAIN AT A MAXIMUM HEIGHT OF 3'-0". STRUCTURES AND LANDSCAPING WITHIN A TRIANGLE MEASURED BACK 10' FROM THE PROPERTY LINE AND 20' ALONG THE PROPERTY LINE ON EACH SIDE OF DRIVEWAY ENTRANCES WILL BE MAINTAINED AT A MAXIMUM HEIGHT OF 3'-0".
N.T.S.
LOT ADDRESS: PARCEL NUMBER: PPIN:
PROPERTY ZONE:
67' R.O.W.
SEPARATE CONTIGUOUS BUILDING
BARBED WIRE FENCE
CL
0 1393R 73C12-4 0.5 0 PARCEL 12 3 7
NORTH
906 S. MAGNOLIA ST.
CONTIGUOUS PARCEL PIN: PARCEL LABEL: MAP: DEEDED ACRES: APPRAISED ACRES: F CODE: SECTION: TOWNSHIP: RANGE:
139' PL
PL 156.40'
31.234462 -90.447359 28840
156.40' PL
LATITUDE: LONGITUDE: PARCEL PIN:
LV YB
906 S. MAGNOLIA ST. McCOMB, MS, 39648
2. STRUCTURES AND LANDSCAPING WITHIN A TRIANGLE MEASURED BACK 10 FEET FROM THE PROPERTY LINE AND 20 FEET ALONG THE PROPERTY LINE ON EACH SIDE OF THE DRIVEWAY ENTRANCES WILL BE MAINTAINED AT A MAXIMUM HEIGHT OF 3'-0".
8. ALL ON-SITE WATER LINES, INCLUDING THOSE REQUIRED FOR FIRE PROTECTION SHALL BE PRIVATE PLUMBING LINES SUBJECT TO THE MISSISSIPPI PLUMBING CODE.
site plan
2021 INTERNATIONAL BUILDING CODE (IBC) 2021 INTERNATIONAL EXISTING BUILDING CODE (IEBC) 2021 INTERNATIONAL ENERGY CONSERVATION CODE (IECC) 2021 INTERNATIONAL MECHANICAL CODE (IMC) 2020 NATIONAL ELECTRICAL CODE / (NEC)/NFPA 70 2021 INTERNATIONAL PLUMBING CODE (IPC) 2021 NATIONAL FIRE PROTECTION ASSOCIATION (NFPA 101 - LIFE SAFETY CODE) 2021 NATIONAL FIRE PROTECTION ASSOCIATION (NFPA 1 - FIRE CODE) 2021 INTERNATIONAL FIRE CODE (IFC)
1. DEVELOPMENT AND USE OF THIS SITE WILL CONFORM TO ALL APPLICABLE CODES AND ORDINANCES.
CROWN - 906 S. MAGNOLIA - CANNABIS FACILITY
THE MISSISSIPPI BUILDING CONSTRUCTION CODE CONSISTS OF THE STATE ADMINISTRATIVE PROVISIONS, THE FOLLOWING CODES AND STANDARDS, AND STATE OF MISSISSIPPI AMENDMENTS THERETO:
N
INDEX
THIS DRAWING IS AN INSTRUMENT OF SERVICE AND AS SUCH SHALL REMAIN THE PROPERTY OF
TRBDESIGNCONSULTANT UNAUTHORIZEDUSEORREPRODUCTIONWITHOUT
PERMISSION OF THE ARCHITECT IS PROHIBITED. THIS DRAWING IS ONLY FOR USE IN CONNECTION WITHTHIS
PROJECTANDSHALLNOTBEUSED FOROTHERLOCATIONS.COPYRIGHT2015
,
T.R. BADGER-ARCHITECUTURAL/ENGINEERINGDESIGNERTRBDESIGNCONSULTANT
TOTAL PARKING SPACES REQUIRED = 5 SPACES TOTAL PARKING PROVIDED = 10 SPACES TOTAL PARKING RATIO PER 1,000 S.F.=. 2 SPACES
PL 139'
CONSULTANT CROWNCANNABIS FACILITY
* INCLUDES 1 LOADING AND 1 VAN ACCESSIBLE SPACE
DATA
FINAL BUILDING PERMIT CANNOT BE OBTAINED UNTIL BONDING OR APPROVED ASSURANCES ARE PROVIDED FOR THE EXISTING LANDSCAPING WITHIN THE RIGHT OF WAY. ALL PLANT MATERIAL AND SPECIFICATIONS TO CONFORM TO THE MISSISSIPPI NURSERYMAN ASSOCIATION STANDARDS.
TB.DWG
ALL RIGHT OF WAY AND CITY REQUIRED (PERIMETER, RETENTION AND PARKING) PLANT MATERIAL TO BE IN COMPLIANCE WITH THE DEPARTMENT OF WATER RESOURCES LOW WATER USE PLANT LIST. ALL EXISTING TREES AND SHRUBS IN RIGHT OF WAY DESIGNATED TO REMAIN BUT ARE DAMAGED OR DESTROYED WILL BE REMOVED WITHOUT REPLACEMENT. ANY EXISTING ON SITE ACCESSIBLE SIDEWALKS SHALL BE A MIN. OF 3 FEET WIDE AND HAVE A MAX. SLOPE OF 1:20 WITH THE MAX. CROSS SLOPE OF 1:50. ANY EXISTING CURBS MUST PROVIDE ACCESSIBILITY RAMPS PURSUANT TO THE AMERICANS WITH DISABILITIES ACT STANDARDS.
Date: OCTOBER/2022 Job No: Project Mgr: TR Badger Drawn By: Checked By: -
NORTH
TREES ADJACENT TO PEDESTRIAN WALKWAYS SHOULD HAVE A MIN. CANOPY CLEARANCE OF 6 FEET 8 INCHES.
LANDSCAPE NOTES
EXISTING SITE PLAN
SCALE - 1"=20'
CITY STAMP
SITE
N
139' PL
67' R.O.W.
SEPARATE CONTIGUOUS BUILDING
BARBED WIRE FENCE
CONCRETE PARKING LOT
EXISTING FOOTPRINT ON SITE PLAN
PL 156.40'
EXIST'G. BUILDING 4770 S.F.
156.40' PL
S00 39'50"W(R) S00°32'35"W 156.40' 156.40' (R)
CROWN - 906 S. MAGNOLIA - CANNABIS FACILITY
EXIST'G. DIRT DRIVEWAY
CL
906 S. MAGNOLIA ST.
A.P.N. 501393R
906 S. MAGNOLIA ST. McCOMB, MS, 39648
WEST(R) S89°50'18"W 138.94' 139.00'(R)
THIS DRAWING IS AN INSTRUMENT OF SERVICE AND AS SUCH SHALL REMAIN THE PROPERTY OF
BARBED WIRE FENCE
TRBDESIGNCONSULTANT UNAUTHORIZEDUSEORREPRODUCTIONWITHOUT
PERMISSION OF THE ARCHITECT IS PROHIBITED. THIS DRAWING IS ONLY FOR USE IN CONNECTION WITHTHIS
PROJECTANDSHALLNOTBEUSED FOROTHERLOCATIONS.COPYRIGHT2015
,
T.R. BADGER-ARCHITECUTURAL/ENGINEERINGDESIGNERTRBDESIGNCONSULTANT
CONSULTANT CROWNCANNABIS FACILITY
N00 39'50"E(R) N00°31'13"E 156.36' 156.40'(R) TB.DWG
PL 139'
EAST(R) N89°49'26"E 139.00'
EXISTING FOOTPRINT ON SITE PLAN
Date: OCTOBER/2022 Job No: Project Mgr: TR Badger Drawn By: Checked By: -
1/8" = 1'-0"
A101
N
139' PL
existing building open space existing building open space
67' R.O.W.
SEPARATE BUILDING
BARBED WIRE FENCE
CONCRETE PARKING LOT
EXISTING FLOOR PLAN ON SITE PLAN
EXISTING BUILDING OPEN SPACE
156.40' PL
S00 39'50"W(R) S00°32'35"W 156.40' 156.40' (R)
PL 156.40'
under roof patio
CROWN - 906 S. MAGNOLIA - CANNABIS FACILITY
EXIST'G. DIRT DRIVEWAY
CL
906 S. MAGNOLIA ST.
A.P.N. 501393R
906 S. MAGNOLIA ST. McCOMB, MS, 39648
WEST(R) S89°50'18"W 138.94' 139.00'(R)
THIS DRAWING IS AN INSTRUMENT OF SERVICE AND AS SUCH SHALL REMAIN THE PROPERTY OF
BARBED WIRE FENCE
TRBDESIGNCONSULTANT UNAUTHORIZEDUSEORREPRODUCTIONWITHOUT
PERMISSION OF THE ARCHITECT IS PROHIBITED. THIS DRAWING IS ONLY FOR USE IN CONNECTION WITHTHIS
PROJECTANDSHALLNOTBEUSED FOROTHERLOCATIONS.COPYRIGHT2015
,
T.R. BADGER-ARCHITECUTURAL/ENGINEERINGDESIGNERTRBDESIGNCONSULTANT
CONSULTANT CROWNCANNABIS FACILITY
N00 39'50"E(R) N00°31'13"E 156.36' 156.40'(R) TB.DWG
PL 139'
EAST(R) N89°49'26"E 139.00'
EXISTING FLOOR PLAN ON SITE PLAN
Date: OCTOBER/2022 Job No: Project Mgr: TR Badger Drawn By: Checked By: -
1/8" = 1'-0"
A102
N 68'-0"
13'-5"
2'-6"
13'-5"
THIS DRAWING IS AN INSTRUMENT OF SERVICE AND AS SUCH SHALL REMAIN THE PROPERTY OF
1'-8"
25'-5"
4'-2"
906 S. MAGNOLIA ST. McCOMB, MS, 39648
2'-6"
7'-5"
19'-5" 15'-1"
19'-5"
9'-11"
26'-11"
existing building open space 7'-8"
16'-1"
16'-5"
11'-3"
40'-2"
EXISTING FLOOR PLAN
existing building open space
11'-9"
CROWN - 906 S. MAGNOLIA - CANNABIS FACILITY
9'-4"
39'-4"
15'-1"
75'-11"
8'-2"
59'-5"
4'-0"
20'-1"
15'-4" 60'-4"
3'-0"
20'-1"
existing building open space
43'-11"
under roof patio
11'-9"
9'-10"
9'-11"
11'-7"
19'-4"
19'-4"
3'-8"
1'-10"
7'-10"
13'-5"
2'-2"
40'-2"
3'-8"
27'-0"
TRBDESIGNCONSULTANT UNAUTHORIZEDUSEORREPRODUCTIONWITHOUT
PERMISSION OF THE ARCHITECT IS PROHIBITED. THIS DRAWING IS ONLY FOR USE IN CONNECTION WITHTHIS
PROJECTANDSHALLNOTBEUSED FOROTHERLOCATIONS.COPYRIGHT2015
8'-5"
CROWNCANNABIS FACILITY
15'-3"
SEPARATE BUILDING
5'-10"
4'-5"
TB.DWG
CONSULTANT
6'-4"
15'-1"
19'-8"
10'-7"
15'-7"
11'-9"
21'-6"
14'-3"
8'-0"
8'-4"
2'-3"
NORTH 42'-10"
24'-1"
Date: OCTOBER/2022 Job No: Project Mgr: TR Badger Drawn By: Checked By: -
68'-2"
EXISTING FLOOR PLAN
,
T.R. BADGER-ARCHITECUTURAL/ENGINEERINGDESIGNERTRBDESIGNCONSULTANT
1/4" = 1'-0"
A103
N
139' PL WEST(R) S89°50'18"W 138.94' 139.00'(R)
SURVEILLANCE CAMERA (720p RESOLUTION) SURVEILLANCE VIDEO DIGITAL ARCHIVE DEVICE COLOR PRINTER
PL 156.40'
VIDEO MONITOR
156.40' PL
S00 39'50"W(R) S00°32'35"W 156.40' 156.40' (R)
DIGITAL ARCHIVE DEVICE SECURITY CAGE OUTDOOR FLOOD LIGHT UNINTERRUPTIBLE POWER SUPPLY (UPS) BATTERY BACKUP
NOTES: LOCK, ALARM, & SURVEILLANCE · APPLICANT’S SECURITY PLAN MEETS OR EXCEEDS 15 MISS.
CODE R. § 22-5-1.10.5, § 22-5-1.10.6, § 22-5-1.10.7, AND § 22-5-1.10.8 · REFER TO APPLICANT’S SECURITY OPERATING PLAN FOR
SECURITY PLAN AND SYSTEM SPECIFICS
· THE EXTERIOR WIRE SECURITY ROOM AND PARKING AREA PERIMETER SECURITY FENCE ARE COVERED WITH PRIVACY SCREEN
BARBED WIRE FENCE
NEW BUILDING 1.620 s.f.
BARBED WIRE FENCE CONCRETE PARKING LOT
TB.DWG
BARBED WIRE FENCE
PL 139'
906 S. MAGNOLIA ST. McCOMB, MS, 39648
ALARM SYSTEM MOTION DETECTOR
NEW FLOOR/SECURITY PLAN ON SITE PLAN
EXIST'G. DIRT DRIVEWAY
ALARM SYSTEM MAGNETIC DOOR CONTACT SWITCH
CROWN - 906 S. MAGNOLIA - CANNABIS FACILITY
ALARM SYSTEM CONTROL KEYPAD
CL
LEGEND: ALARM & SURVEILLANCE
906 S. MAGNOLIA ST.
A.P.N. 501393R
THIS DRAWING IS AN INSTRUMENT OF SERVICE AND AS SUCH SHALL REMAIN THE PROPERTY OF
TRBDESIGNCONSULTANT UNAUTHORIZEDUSEORREPRODUCTIONWITHOUT
PERMISSION OF THE ARCHITECT IS PROHIBITED. THIS DRAWING IS ONLY FOR USE IN CONNECTION WITHTHIS
PROJECTANDSHALLNOTBEUSED FOROTHERLOCATIONS.COPYRIGHT2015
,
T.R. BADGER-ARCHITECUTURAL/ENGINEERINGDESIGNERTRBDESIGNCONSULTANT
gate door
CONSULTANT CROWNCANNABIS FACILITY
N00 39'50"E(R) N00°31'13"E 156.36' 156.40'(R)
EAST(R) N89°49'26"E 139.00'
NEW FLOOR/SECURITY PLAN ON SITE PLAN
Date: OCTOBER/2022 Job No: Project Mgr: TR Badger Drawn By: Checked By: -
1/8" = 1'-0"
A104
N
906 S. MAGNOLIA ST. McCOMB, MS, 39648
CULTIVATION ACTIVITY DRIED CANNABIS CURING & STORAGE
cultivation activity: flowering growth phase
CULTIVATION ACTIVITY: TRIMMING, PACKAGING & LABELING
cultivation activity: drying cannabis
cultivation activity: labeled cannabis packages secure storage
RESTRICTED AREAS
cultivation activity: propagation and vegetative growth phases
SHADED RESTRICTED AREAS IN BUILDING
cultivation activity: flowering growth phase
CROWN - 906 S. MAGNOLIA - CANNABIS FACILITY
curing, secure storage, & qa quarantine room
THIS DRAWING IS AN INSTRUMENT OF SERVICE AND AS SUCH SHALL REMAIN THE PROPERTY OF
TRBDESIGNCONSULTANT UNAUTHORIZEDUSEORREPRODUCTIONWITHOUT
PERMISSION OF THE ARCHITECT IS PROHIBITED. THIS DRAWING IS ONLY FOR USE IN CONNECTION WITHTHIS
PROJECTANDSHALLNOTBEUSED FOROTHERLOCATIONS.COPYRIGHT2015
,
T.R. BADGER-ARCHITECUTURAL/ENGINEERINGDESIGNERTRBDESIGNCONSULTANT
cultivation activity: cannabis waste secure storage
CONSULTANT CROWNCANNABIS FACILITY
restroom
office TB.DWG
NORTH
SHADED RESTRICTED AREAS IN BUILDING
1/4" = 1'-0"
Date: OCTOBER/2022 Job No: Project Mgr: TR Badger Drawn By: Checked By: -
A105
N
68'-0" 40'-6"
27'-1" 26'-6"
6"
5"
5"
5'-9"
1'-3" 12'-2"
10'-0"
A A-16
irrigation 109
B A-16
18'-0"
18'-0"
7"
laboratory 110
secure wire room: chemical storage 108
40'-11"
8'-9"
5"
4'-1"
36'-9"
114
111
4'-10"
7'-6"
7'-6"
7'-6"
9'-3"
8'-11"
10'-10"
open area 112
7'-0" 6'-7"
cultivation activity: propagation and vegetative growth phases
16'-0"
2'-9" 8'-0"
unisex toliet 103
6'-0"
7'-4"
104
9'-4"
unisex changing room 102
vestibule 101
10'-6" 7'-3"
main entrance & exit
6"
26'-1"
7'-0"
5"
17'-1"
18'-1"
9'-0"
12'-9"
20'-3"
39'-10"
6'-0"
4'-2"
4'-10"
12'-1"
4'-0"
5"
7'-6"
cannabis product secure store. 105
75'-10"
C A-17
3'-0" 8"
C A-17
906 S. MAGNOLIA ST. McCOMB, MS, 39648
113
39'-10"
cultivation activity: flowering growth phase
NEW FLOOR PLAN
cultivation activity: trimming, packaging & labeling
16'-4"
106
21'-1"
60'-3"
cultivation activity: drying cannabis
cultivation activity: flowering growth phase
39'-7"
17'-4"
CROWN - 906 S. MAGNOLIA - CANNABIS FACILITY
cultivation activity: dried cannabis curing & storage 107
41'-6"
6'-6"
17'-4"
shipping & receiving
THIS DRAWING IS AN INSTRUMENT OF SERVICE AND AS SUCH SHALL REMAIN THE PROPERTY OF
TRBDESIGNCONSULTANT UNAUTHORIZEDUSEORREPRODUCTIONWITHOUT
PERMISSION OF THE ARCHITECT IS PROHIBITED. THIS DRAWING IS ONLY FOR USE IN CONNECTION WITHTHIS
PROJECTANDSHALLNOTBEUSED FOROTHERLOCATIONS.COPYRIGHT2015
,
T.R. BADGER-ARCHITECUTURAL/ENGINEERINGDESIGNERTRBDESIGNCONSULTANT
unisex toliet 202
CONSULTANT
14'-2"
15'-7"
301
office
CROWNCANNABIS FACILITY
17'-6"
7'-11"
8'-1"
cultivation activity: cannabis waste secure storage
5'-10"
24'-0"
8'-4" TB.DWG
A A-16
5'-7"
201
NORTH
B A-16
25'-5"
NEW FLOOR PLAN
1/4" = 1'-0"
Date: OCTOBER/2022 Job No: Project Mgr: TR Badger Drawn By: Checked By: -
A106
27'-1" 26'-6"
18'-0"
18'-0"
C-1
6"
EXIST'G METAL SIDING
4-3/4"
6"
N
40'-11" 40'-6" 36'-9" 7"
5"
5"
1'-1"
68'-0"
14
14 WS-01
5'-9" 4'-1"
10'-0"
12'-2"
secure chemical 1-c storage 13 108
5
C-1
FS-02
FS-01
1 A109
laboratory 110
5"
5"
EXIST'G METAL SIDING
13
curing, secure storage, & qa quarantine room 107
14
13
drying room
4-7/8"
20'-1"
106
113
5
C-1
114
6
5
trimming, packaging and labeling 111
7'-3"
114
WIRE MESH PARTITIONS 8'-0" HIGH. LOCKING MESH DOOR. OWNER SUPPLIED.
OFFICE AHU CUBBY 1A
6'-0"
EXIST'G WALLS & METAL SIDING
EX
unisex toliet 202 202
75'-8" 4-3/4" 4-3/4" 4-1/16" 101-1
1A
19'-7"
TRBDESIGNCONSULTANT UNAUTHORIZEDUSEORREPRODUCTIONWITHOUT
PERMISSION OF THE ARCHITECT IS PROHIBITED. THIS DRAWING IS ONLY FOR USE IN CONNECTION WITHTHIS
PROJECTANDSHALLNOTBEUSED FOROTHERLOCATIONS.COPYRIGHT2015
,
T.R. BADGER-ARCHITECUTURAL/ENGINEERINGDESIGNERTRBDESIGNCONSULTANT
CONSULTANT
EXIST'G DOORS TO REMAIN
EXIST'G DOORS TO REMAIN
201
office
CROWNCANNABIS FACILITY
201 EX
4'-0"
EXIST'G WALLS & METAL SIDING
24'-0"
LEGEND C-1 & C-2
vestibule 101
5'-7"
EXIST'G METAL SIDING
1-A
8'-4"
1
1A
THIS DRAWING IS AN INSTRUMENT OF SERVICE AND AS SUCH SHALL REMAIN THE PROPERTY OF
7'-11"
8'-1"
EXIST'G WALLS & METAL SIDING
4-5/8"
5'-7"
1-C
EXIST'G METAL SIDING
changing room 1 102
101-2
6"
10'-6"
2
2A
5'-10"
TB.DWG
cannabis waste secure storage 301
WIRE MESH PARTITIONS 8'-0". WIRE MESH CLOSURE CEILING LOCKING MESH DOOR. OWNER SUPPLIED.
4-5/8" unisex
unisex toliet 103
1
6"
5" 1'-9" 2'-6"
15'-7"
1-B
WIRE MESH PARTITIONS 10'-0" HIGH. WIRE MESH CLOSURE CEILING. LOCKING MESH DOOR. PRIVACY FENCE WINDSCREEN OVER WALLS AND DOOR. OWNER SUPPLIED.
102
103
8'-4"
8" 8'-0"
7'-4"
12'-9"
10
115
1
2
5'-10"
fs-04
3'-6"
3"
2
9'-4"
6'-6"
6'-7"
26'-1"
2'-0"
shipping & receiving
104-1
1 A109
6"
1-A
7'-0"
4-3/4"
EXIST'G METAL SIDING
KEYNOTE
3
17'-6"
4'-2" 8
5"
propagation and vegetative room 104
16'-0"
7
open area 112
7'-0"
11
5"
8'-11"
4
39'-10"
9
17'-1"
C-1
15'-8"
4
18'-1"
5"
112
C-1
4"-1/16"
6"
4-3/4" 20'-3"
9'-0"
17'-1"
7'-6" 114
9'-3"
4'-0"
8'-1" 104-2
7'-6"
113 7
C-1
C-1
4'-10"
12'-0"
C-1
7'-6"
10'-10"
1-c
7'-6"
6'-0"
4'-0"
5"
9
cannabis product secure store. 105
C-1
14'-2"
13
C-2
8"
12
6"
106
906 S. MAGNOLIA ST. McCOMB, MS, 39648
8'-9"
17'-4"
C-2
NEW FLOOR PLAN (DETAIL)
C-1
flowering rooms cultivation activity: generative growth phase room #2
39'-7"
C-2
flowering rooms cultivation activity: generative growth phase room #1
39'-7"
41'-6"
13
CROWN - 906 S. MAGNOLIA - CANNABIS FACILITY
107
6"
14
5"
7'-6"
5
C-1
1 A109
17'-4"
60'-3"
1'-3"
irrigation 109
FS-03
EXIST'G WALLS & METAL SIDING
NORTH
25'-5"
REFER TO SHEET A107
NEW FLOOR PLAN (DETAIL)
1/4" = 1'-0"
Date: OCTOBER/2022 Job No: Project Mgr: TR Badger Drawn By: Checked By: -
A107
8" 7'-6"
27'-4"
12'-6"
WS-01
irrigation 109
FS-01: 12" x 12" FLOOR SINK 6" DEPTH (ZURN Z1900-4) DRAIN PIPE CONNECTION TO EXISTING SANITARY SEWER LINE OUTS OF N WALL FS-02: 12" x 12" FLOOR SINK 6" DEPTH (ZURN Z1900-4) DRAIN CONNECTION TO FS-01 UNDER CENTER WALL BETWEEN ROOMS
CITY WATER PIPE GAS PIPE
N
3"
3" LEGEND
SANITARY SEWER PIPE
29'-4" 28'-2"
secure chemical storage 108
FS-03 FS-02
FS-01
laboratory 110
12" x 12" FLOOR SINK 6" DEPTH (ZURN Z1900-4) DRAIN PIPE CONNECTION TO EXISTING SANITARY SEWER LINE OUTS OF N WALL
curing, secure storage, & qa quarantine room 107
-
12" x 12" FLOOR SINK 6" DEPTH (ZURN Z1900-4) DRAIN PIPE CONNECTION TO EXISTING SANITARY SEWER LINE FROM TOILET ROOM IN OFFICE
WS-01: -
flowering rooms cultivation activity: generative growth phase room #1
flowering rooms cultivation activity: generative growth phase room #2
113
114
1" CITY WATER CONNECTION
drying room
trimming, packaging and labeling 111
106
KEYNOTES 1
WALL MOUNTED TOILET, CONNECT TO EXISTING SANITARY SEWER LINE FROM TOILET ROOM IN OFFICE.
2
WALL MOUNTED TOILET, CONNECT TO EXISTING SANITARY SEWER LINE FROM TOILET ROOM IN OFFICE.
3
WALL MOUNTED TOILET, CONNECT TO EXISTING SANITARY SEWER LINE FROM TOILET ROOM IN OFFICE.
4
FLOOR CUT FOR DRAIN PIPE FROM FS-04.
CROWN - 906 S. MAGNOLIA - CANNABIS FACILITY
FS-04:
cannabis product secure store. 105
open area 112
vegetative & propogation
shipping & receiving
104
fs-04
115
4
unisex toliet 103
4
unisex changing room 102
vestibule 101
4
8"
NOTES
3"
4
NEW FLOOR PLAN (DETAIL)
-
906 S. MAGNOLIA ST. McCOMB, MS, 39648
FS-03:
BASED ON EXISTING DIMENSIONS AND CONDITIONS GENERAL CONTRACTOR SHALL DESIGN AND FINALIZE PLANS FOR KEYNOTES 1 THROUGH 4.
THIS DRAWING IS AN INSTRUMENT OF SERVICE AND AS SUCH SHALL REMAIN THE PROPERTY OF
TRBDESIGNCONSULTANT UNAUTHORIZEDUSEORREPRODUCTIONWITHOUT
PERMISSION OF THE ARCHITECT IS PROHIBITED. THIS DRAWING IS ONLY FOR USE IN CONNECTION WITHTHIS
PROJECTANDSHALLNOTBEUSED FOROTHERLOCATIONS.COPYRIGHT2015
unisex toliet 202
cannabis waste secure storage 301
,
T.R. BADGER-ARCHITECUTURAL/ENGINEERINGDESIGNERTRBDESIGNCONSULTANT
CONSULTANT CROWNCANNABIS FACILITY
office 201
TB.DWG
NORTH
FLOOR CUT PLAN
1/4" = 1'-0"
Date: OCTOBER/2022 Job No: Project Mgr: TR Badger Drawn By: Checked By: -
A108
N
12'-0"
ST
ST
ST
ST
2'-0" 2'-0" 2'-0" 2'-0"
4'-0"
6'-0" laboratory 110
secure chemical storage 108
240V 240V
6'-6"
MESH SECURITY FENCE (BY OTHERS)
4'-0"
5'-0"
5'-0"
9'-2"
8'-6"
FERTIGATION PUMPS: 240V @ 4.8FLA
cannabis product secure store. 105
3'-0"
4'-6"
6
6'-0"
AIR COMPRESSOR; 230V @ 21.5FLA
4
6'-0"
MESH SECURITY FENCE (BY OTHERS)
6'-0"
6'-0"
6'-0"
8'-0"
open area 112
3"
- 120V DUPLEX @ 72" - ONE WALL FAN @ 1.1A
120V QUADRUPLEX @ 48" FROM FLOOR
3'-9" 5/16"
4"
4"
3"
1
1
4'-6"
unisex toliet 103
shipping & receiving 115
6'-0"
6'-0"
6'-0"
2'-0"
120V DUPLEX @ 54"
vegetative & propagation
3'-0"
ST
5'-0"
104
3'-9" 5/16"
240V
5'-0"
5'-0"
- LED GROW LIGHT DRIVER 9"x6"x3" LxWxH (REF E102) - INSTALL THE DRIVERS FOR ON TOP OR TOP EDGES OF THE GROW RACK
SEE KEYNOTES
5'-0"
5'-0"
NOTES
unisex changing room 102
906 S. MAGNOLIA ST. McCOMB, MS, 39648
6'-0"
4'-0"
4'-0"
for typ. luminaire layout see flowering room 113
ELECTRICAL PLAN (POWER & AUXILIARY)
4'-0"
8'-0" 4'-0"
CROWN - 906 S. MAGNOLIA - CANNABIS FACILITY
4'-0" 4'-0"
106
10'-0"
1
114
113
4'-0"
8'-0"
trimming, packaging and labeling 111
LED GROW LIGHT (E102)
flowering
flowering 6'-0"
8'-0"
240V
drying room
- A TOTAL OF TEN (10) LED GROW LIGHTS (TWO LEVELS OF FIVE (5) LED GROW LIGHTS) - LED LIGHTS AFFIXED TO A MOBILE RACK SYSTEM (EX MONTEL "GREENRACK") - LOCAL CONTRACTOR TO PLAN POWER DISTRIBUTION TO LED LIGHTS (REF E102); RMTE DRV INSTALL
6
240V
8'-8"
1
12'-0"
(TYP OF 4)
curing, secure storage, & qa quarantine room 107
KEYNOTES:
6'-8"
6'-0"
6
1'-0"
ST
6'-0"
ST
6'-0"
4'-6"
4'-0"
8'-6"
irrigation 109
vestibule 101
GFI
240V
4
THIS DRAWING IS AN INSTRUMENT OF SERVICE AND AS SUCH SHALL REMAIN THE PROPERTY OF
TRBDESIGNCONSULTANT UNAUTHORIZEDUSEORREPRODUCTIONWITHOUT
PERMISSION OF THE ARCHITECT IS PROHIBITED. THIS DRAWING IS ONLY FOR USE IN CONNECTION WITHTHIS
PROJECTANDSHALLNOTBEUSED FOROTHERLOCATIONS.COPYRIGHT2015
cannabis waste secure storage 301
NOTES RM/AREA 101 - 103 104 - 105 106 - 107 108 & 110 109
unisex toliet 202
,
T.R. BADGER-ARCHITECUTURAL/ENGINEERINGDESIGNERTRBDESIGNCONSULTANT
CONSULTANT CROWNCANNABIS FACILITY
CIRCUITS/BREAKERS/OUTLETS x1 120V 20A x2 120V 20A x2 120V 20A x1 120V 20A x2 120V 20A: SEE KEYNOTES
RM/AREA 111 112 & 115 113 114 201
CIRCUITS/BREAKERS/OUTLETS x1 120V 20A x2 120V 20A x2 120V 20A x1 120V 20A x2 120V 20A
office 201
TB.DWG -
CEILING OUTLET PLAY BY LOCAL CONTRACTOR (REF E102)
-
HVAC POWER DISTRIIBUTION PLAN BY LOCAL CONTRACTOR (REF M101)
NORTH
ELECTRICAL PLAN (POWER & AUXILIARY)
1/4" = 1'-0"
Date: OCTOBER/2022 Job No: Project Mgr: TR Badger Drawn By: Checked By: -
E101
N 12'-4"
2'-8" MESH SECURITY FENCE (BY OTHERS)
secure chemical stor. 1'-8" 108
3'-8"
2'-8"
10"
flowering
2
114
106
4'-2"
1'-10"
flowering
(TYP OF ALL)
113
4'-6"
2'-8"
1'-4"
(TYP OF ALL)
shipping & receiving
1'-0"
6"
unisex toliet 103
3'-8"
5'-2"
104
2
2'-8"
115 vegetative & propagation
1"-1/4"
open area 112
unisex changing 1'-9" room 102
2
2'-8"
vestibule 101 2
2'-11"
12'-7 1/4" 8'-6 5/8"
4'-0" 8'-1"
16'-8"
2'-0"
20'-9"
2'-0"
2
2'-8"
8'-3"
MESH SECURITY FENCE (BY OTHERS)
cannabis product secure store. 105
16'-10"
12'-3" 1
3'-9" 5/16"
3'-0"
2'-4"
7'-7"
3'-9" 5/16"
6" 1'-4"
1'-4" 1'-6"
1'-4"
6'-4"
9-3/4"
21'-6"
10"
4'-2"
2'-11"
drying room
30'-7 1/2" 35'-2 1/2"
trimming, packaging and labeling 111
26'-1"
3'-10"
for typ. luminaire layout see flowering room 113
906 S. MAGNOLIA ST. McCOMB, MS, 39648
10"
3'-2"
curing, secure storage, & qa quarantine room 107
REFLECTIVE CEILING PLAN (LUMINAIRES)
10"
CROWN - 906 S. MAGNOLIA - CANNABIS FACILITY
1'-10"
laboratory 110
10"
1'-8"
1'-4"
1'-11"
irrigation 109
9-3/4"
1'-4"
2
8'-4"
1'-8"
7'-1"-3/8"
THIS DRAWING IS AN INSTRUMENT OF SERVICE AND AS SUCH SHALL REMAIN THE PROPERTY OF
TRBDESIGNCONSULTANT UNAUTHORIZEDUSEORREPRODUCTIONWITHOUT
PERMISSION OF THE ARCHITECT IS PROHIBITED. THIS DRAWING IS ONLY FOR USE IN CONNECTION WITHTHIS
PROJECTANDSHALLNOTBEUSED FOROTHERLOCATIONS.COPYRIGHT2015
KEYNOTE
cannabis waste secure storage 301
unisex toliet 202
,
T.R. BADGER-ARCHITECUTURAL/ENGINEERINGDESIGNERTRBDESIGNCONSULTANT
CONSULTANT CROWNCANNABIS FACILITY
office 201
TB.DWG
NORTH
REFLECTIVE CEILING PLAN (LUMINAIRES)
1/4" = 1'-0"
Date: OCTOBER/2022 Job No: Project Mgr: TR Badger Drawn By: Checked By: -
E102
13'-1" 10'-1" 7'-11" 4'-11" 2'-9"
N
15'-3"
12'-2"
laboratory 110
secure chemical storage 108
8'-10"
irrigation 109
10'-3"
114
113
for typ. luminaire layout see flowering room 113
(TYP. OF 4)
2 trimming, packaging and labeling 111
drying room 106
5'-3" 3'-4"
5'-3" 3'-4"
5'-10"
10'-9"
7'-9"
4 (TYP. OF 4)
2'-9"
cannabis product secure store. 105
1 (TYP. OF 6)
1'-6"
open area 112
2
vegetative & propagation 104
8'-2"
(TYP. OF 2)
4'-3"
6'-0"
3
15'-5"
13'-6"
(TYP. OF 2)
shipping & receiving 115
unisex toliet 103
unisex changing room 102
vestibule 101
REFLECTIVE CEILING PLAN (UNITRUST)
CROWN - 906 S. MAGNOLIA - CANNABIS FACILITY
flowering
flowering
906 S. MAGNOLIA ST. McCOMB, MS, 39648
curing, secure storage, & qa quarantine room 107
THIS DRAWING IS AN INSTRUMENT OF SERVICE AND AS SUCH SHALL REMAIN THE PROPERTY OF
TRBDESIGNCONSULTANT UNAUTHORIZEDUSEORREPRODUCTIONWITHOUT
PERMISSION OF THE ARCHITECT IS PROHIBITED. THIS DRAWING IS ONLY FOR USE IN CONNECTION WITHTHIS
PROJECTANDSHALLNOTBEUSED FOROTHERLOCATIONS.COPYRIGHT2015
cannabis waste secure storage 301
unisex toliet 202
,
T.R. BADGER-ARCHITECUTURAL/ENGINEERINGDESIGNERTRBDESIGNCONSULTANT
CONSULTANT CROWNCANNABIS FACILITY
office 201
TB.DWG
NORTH
REFLECTIVE CEILING PLAN (UNITRUST)
1/4" = 1'-0"
Date: OCTOBER/2022 Job No: Project Mgr: TR Badger Drawn By: Checked By: -
E103
MAYBE RE-ROOFED
906 S. MAGNOLIA ST. McCOMB, MS, 39648
EXIST'G SKYLIGHTS COVERED AND SEALED NOT TO BE RE-ROOFED
ROOF PLAN
CROWN - 906 S. MAGNOLIA - CANNABIS FACILITY
N
THIS DRAWING IS AN INSTRUMENT OF SERVICE AND AS SUCH SHALL REMAIN THE PROPERTY OF
TRBDESIGNCONSULTANT UNAUTHORIZEDUSEORREPRODUCTIONWITHOUT
PERMISSION OF THE ARCHITECT IS PROHIBITED. THIS DRAWING IS ONLY FOR USE IN CONNECTION WITHTHIS
PROJECTANDSHALLNOTBEUSED FOROTHERLOCATIONS.COPYRIGHT2015
,
T.R. BADGER-ARCHITECUTURAL/ENGINEERINGDESIGNERTRBDESIGNCONSULTANT
CONSULTANT CROWNCANNABIS FACILITY
TB.DWG
NORTH
ROOF PLAN
1/4" = 1'-0"
Date: OCTOBER/2022 Job No: Project Mgr: TR Badger Drawn By: Checked By: -
R101
A A-16
18'-0"
14'-11"
18'-0" C-1
C-1
9"
C-1
9"
C-1
N
B A-16
W-2
C-2
C-1
20'-1"
20'-0"
B-2
20'-0"
J-5
C-1
J-6
W-1
J-6
W-2
C-2
C A-17
1'-0"
C A-17
C-2
17'-4"
10"
8'-4"
1'-7"
18'-6 21"
C-1
10"
MESH (BY OTHERS)
18'-6 21"
C-1
C-1
C-1
TRACK SIZES
REMARKS
C-1
(2) 400S162-54
(2) 362T200-54
8x8x1/4" BASE PL. W/ (4) 3/4 Ø POST-INSTALLED ANCHORS
C-2
(2) 600S200-54
(2) 400T200-54
10x10x1/4" BASE PL. W/ (4) 3/4 Ø POST-INSTALLED ANCHORS
C-1
J-3
BEAM FRAMING
6"
8"
1'-5"
MARK
STUD SIZES
TRACK SIZES
B-1
(2) 400S162-54
(2) 362T200-54
(2) STIFFCLIP JC CONNECTORS EA. END, LB. CAPACITY)
B-2
(2) 600S200-54
(2) 400T200-54
(2) STIFFCLIP JC CONNECTORS EA. END, (6,000 LB. CAPACITY) (EX ROOF SUPPORT)
6'-0"
STUD SIZES
12'-11"
MARK
RB-1
COLUMN FRAMING
20'-0"
B-1
6"
6"
J-1
6" J-1
8"
8" J-1
REMARKS (6,000 THIS DRAWING IS AN INSTRUMENT OF SERVICE AND AS SUCH SHALL REMAIN THE PROPERTY OF
TRBDESIGNCONSULTANT UNAUTHORIZEDUSEORREPRODUCTIONWITHOUT
PERMISSION OF THE ARCHITECT IS PROHIBITED. THIS DRAWING IS ONLY FOR USE IN CONNECTION WITHTHIS
C-1
PROJECTANDSHALLNOTBEUSED FOROTHERLOCATIONS.COPYRIGHT2015
,
T.R. BADGER-ARCHITECUTURAL/ENGINEERINGDESIGNERTRBDESIGNCONSULTANT
JOIST FRAMING
TB.DWG
STRUCTURAL FRAMING PLAN
CROWN - 906 S. MAGNOLIA - CANNABIS FACILITY
8"
1'-0"
8"
906 S. MAGNOLIA ST. McCOMB, MS, 39648
6'-6"
J-1
20'-0"
20'-0"
19'-5"
MESH (BY OTHERS)
MARK
JOIST SIZES
B.STIL
REMARKS
J-1 J-2 J-3 J-4 J-5 J-6
600S162-43 @ 24"
8'-0" 8'-0" 8'-0" 9'-0"
PROVIDE CONT'D. LATERAL BRIDGING @ 8' O.C.
TRACK SIZES
REMARKS
NOT USED 800S200-54 @ 24" NOT USED 800S250-68 @ 24" 800S250-68 @ 24"
PROVIDE CONT'D. LATERAL BRIDGING @ 8' O.C. PROVIDE CONT'D. LATERAL BRIDGING @ 8' O.C. PROVIDE CONT'D. LATERAL BRIDGING @ 8' O.C.
CEILING FRAMING PLAN NOTES:
CONSULTANT CROWNCANNABIS FACILITY
1.
GENERAL CONTRACTOR SHALL FIELD VERIFY ALL DIMENSIONS & CONDITIONS PRIOR TO CONSTRUCTION.
2.
DASHED LINES REPRESENT CONT'D. FLAT BAR BRACING.
WALL FRAMING MARK
STUD SIZES
W-1
362S162-43 @ 24"
W-2
362S162-54 @ 24"
TYP. UNLESS NOTED OTHERWISE PROVIDED FLAT BAR LATERAL BRACING PROVIDE FLAT BAR LATERAL BRACING
A A-16
STRUCTURAL FRAMING PLAN
B A-16
NORTH
1/4" = 1'-0"
Date: OCTOBER/2022 Job No: Project Mgr: TR Badger Drawn By: Checked By: -
R102
WHB
N
29'-4"
SANITARY SEWER PIPELINE CITY WATER PIPE GAS PIPE
28'-3" 27'-4"
WS-01
FS-03
irrigation 109
secure chemical storage 108
FS-01
FS-01
WHB
WHB
laboratory 110
114
113
FOR TYP. HVAC LAYOUT SEE FLOWERING ROOM 113 trimming, packaging and labeling 111
drying room 106
cannabis product secure store. 105
open area 112
vegetative & propagation
2
104 3 shipping & receiving WHB
115
FS-04
2
unisex toliet 103
1
unisex changing room 102
PLUMBING PLAN
CROWN - 906 S. MAGNOLIA - CANNABIS FACILITY
flowering
flowering
906 S. MAGNOLIA ST. McCOMB, MS, 39648
curing, secure storage, & qa quarantine room 107
vestibule 101
14
THIS DRAWING IS AN INSTRUMENT OF SERVICE AND AS SUCH SHALL REMAIN THE PROPERTY OF
TRBDESIGNCONSULTANT UNAUTHORIZEDUSEORREPRODUCTIONWITHOUT
PERMISSION OF THE ARCHITECT IS PROHIBITED. THIS DRAWING IS ONLY FOR USE IN CONNECTION WITHTHIS
PROJECTANDSHALLNOTBEUSED FOROTHERLOCATIONS.COPYRIGHT2015
cannabis waste secure storage 301
unisex toliet 202
CONSULTANT CROWNCANNABIS FACILITY
CEILING FRAMING PLAN NOTES:
TB.DWG
3/4" SCH 40 PVC - WHB (WALL-MOUNTED HOSE BIB) - FS-01 FS-04 & WS-01 - HW (HOT WATER) - CW (HOT WATER) - GRAVITY DRAIN TO SEWER - RO WATER 1" SCH 40 PVC - NM (NUTRIENT MIXING) 1" SCH 80 PVC - NF (NUTRIENT FERTIGATION) 1" SCH 80 PVC - COMPRSD AIR (90 PSI @ MAX 18 CFM) COPPER OR ALUMINUM
,
T.R. BADGER-ARCHITECUTURAL/ENGINEERINGDESIGNERTRBDESIGNCONSULTANT
office 201
REFER TO A109
NORTH
PLUMBING PLAN
1/4" = 1'-0"
Date: OCTOBER/2022 Job No: Project Mgr: TR Badger Drawn By: Checked By: -
P101
1 P103
WHB
RO FLTR
RO STOR TNK
BATCH TNK SVs & H20 BYPASS
FS-03
WS-01
1 P104
D. TRON M. FOLD & STOK TNKS
OPT EQP
6
15
5
8
7
IRRIG. SOLENOID VALVE (SV) M. FOLD, SV CTRL, & DRAINAGE
10
9
irrigation 109 secure chemical storage 108
28'-3" 27'-4"
ANDERSON M. FOLD, CTRL, & STOCK TANKS
4
N
29'-4"
SANITARY SEWER PIPELINE CITY WATER PIPE GAS PIPE
FS-01
FS-01 WHB
WHB
BATCH TNK 1
laboratory 110 BATCH TNK 2
114
113
LEGEND:
FOR TYP. HVAC LAYOUT SEE FLOWERING ROOM 113
N
1-2. WALL-MOUNTED ADA-APPROVED HAND SINKS AND TOILET 3. UTILITY SINK: PLASTIC OR SS; 18-24" FRONT TO BACK & 24-36" LEFT TO RIGHT 4. COMMERCIAL SINK: SS; TWO COMPARTMENT (x2 BOWLS @ 17-20" X 17-20" X 12-16") W/ DRAINBOARDS 1-4. CONTRACTORS TO DESIGN AND LAYOUT SINKS AND TOILETS WITH ALL PLUMBING AND PIPING 5. 1200 GPD REVERSE OSMOSIS (RO) FILTRATION SYSTEM (EVOLUTION-RO W/ PRE-EVOLUTION DECHLORINATOR; OR APRVD. EQUL.) 6. 300-500 GALLON RO WATER STORAGE TANK W/ IN-LINE PUMP (DAB SYSBOX MINI 3 - TYP. OF 4; OR APRVD. EQUL.) 7. 20-30 GAL. BLADDER TANK, HOSE RACK, IN-LINE ACTIVATED CARBON FILTER (FOR IRRIGATION) 8. DOSATRON INJECTOR (x3) MANIFOLD AND x3 55-GAL DRUMS (STOCK SOLUTION TANKS #1-3) 9. HE ANDERSON PUMPER (x3) MANIFOLD AND x3 55-GAL DRUMS (STOCK SOLUTION TANKS #4-6) 10. SOLENOID VALVES (SV): AUTOMATED NUTRIENT MIXING AND BATCH TANK REFILL (x3 NETAFIM 61ET1GH2; OR APRVD. EQUL.) 11. FLOWERING RM 114: 150-160 GAL NUTRIENT SOLUTION TANK W/ IN-LINE PUMP (TYP.) 12. FLOWERING RM 113: 150-160 GAL NUTRIENT SOLUTION TANK W/ IN-LINE PUMP (TYP.) 13. VEGETATIVE RM 104: 150-160 GAL NUTRIENT SOLUTION TANK W/ IN-LINE PUMP (TYP.) 14. AIR COMPRESSOR FOR HEA PUMPERS (INGERSOLL RAN SS3L3 OR SS5L5; OR APRVD. EQUL.): 90 PSI @ 6-20 CFM (MIN.-MAX.) W/ 30 GAL. PRESSURE TANK (DRAIN CONDENSATE INTO FLOOR DRAIN) 15. (PER FLOWERING ROOM) IRRIGATION VALVE MANIFOLD (x3 SV), SV CONTROLLER (x2 GROWLINK PIC), & SLOPING DRAIN FOR ALL GROW TRAYS INTO FLOOR SINK. 16. IRRIGATION VALVE MANIFOLD (x3 SV), SV CONTROLLER (x2 GROWLINK PIC), & SLOPING DRAIN FOR ALL GROW TRAYS INTO FLOOR SINK.
trimming, packaging and labeling 111
drying room 106
cannabis product secure store. 105
2 P104
open area 112
VEG. & MOM. IRRIG. SOLENOIDS (SV) M. FOLD, SV CTRL, & DRAINAGE
vegetative & propagation
2
104 3 shipping & receiving WHB
115
FS-04
2
unisex toliet 103
1
unisex changing room 102
PLUMBING PLAN
2 P103
CROWN - 906 S. MAGNOLIA - CANNABIS FACILITY
flowering
flowering
906 S. MAGNOLIA ST. McCOMB, MS, 39648
BATCH TNK 3
curing, secure storage, & qa quarantine room 107
vestibule 101
14
THIS DRAWING IS AN INSTRUMENT OF SERVICE AND AS SUCH SHALL REMAIN THE PROPERTY OF
TRBDESIGNCONSULTANT UNAUTHORIZEDUSEORREPRODUCTIONWITHOUT
PERMISSION OF THE ARCHITECT IS PROHIBITED. THIS DRAWING IS ONLY FOR USE IN CONNECTION WITHTHIS
PROJECTANDSHALLNOTBEUSED FOROTHERLOCATIONS.COPYRIGHT2015
LEGEND:
cannabis waste secure storage 301
unisex toliet 202
,
T.R. BADGER-ARCHITECUTURAL/ENGINEERINGDESIGNERTRBDESIGNCONSULTANT
CONSULTANT CROWNCANNABIS FACILITY
FS-n: FLOOR SINK; REFER TO A109 WS-01 WATER SUPPLY (COLD CITY WATER); REFER TO A109 WHB: WALL-MOUNTED HOUSE BIB (34" SCH 40 PVC PRESSURIZED COLD WATER SUPPLY).
office 201
TB.DWG
NORTH
PLUMBING PLAN
1/4" = 1'-0"
Date: OCTOBER/2022 Job No: Project Mgr: TR Badger Drawn By: Checked By: -
P102
11"
N
8'-1" irrigation 109
14.
5'-8"
10 3'-4"
○ □ □ · · ·
○
·
○
· · · ·
DH-01-5
EV-02-3
7'-2"
2'-0"
7'-0"
16 IN. Ø
36'-0"
22 IN. Ø
16 IN. Ø
8'-1"
3'-6"
1'-2"
5'-6"
4 5'-2"
9
1
8'-1" 5'-7"
1'-2" cannabis product secure store 105
2'-0"
DH-01-3
3
3'-4"
RG-01 765 CFM (TYP. OF 4)
4
4
14'-7"
2'-0"
8
AHU-01-2
AHU-01-3
8
8
AHU-01-4
AHU-01-5
8
16 IN. Ø
2'-0"
4 3
9
16 IN. Ø
9
19'-0" vegetative & propagation
RG-01 765 CFM (TYP. OF 2)
104
2'-0"
9 2 302
(TYP. OF 5)
2'-0"
5'-2"
AHU-01-1
16 IN. Ø
HP-01-2
HP-01-3
HP-01-4
2'-0"
·
CFM BASED ON ASSUMED ESP OF 0.5" W.C. DUCT-MOUNTED RETURN GRILLES DO NOT HAVE FILTERS ENSURE ULTRA LOW LEAKAGE INSTALLATION: RETURN DUCT, FILTER BOX, AND AHU AHU RETURN FILTRATION: ENSURE LOW PRESSURE DROP IN-LINE OR CABINET FILTER INSTALLATION PREFILTER: AT LEAST MERV 8 (PLEATED) FINAL FILTER: AT LEAST MERV 14 (BOX) AHU- 01-x: SIDE PANEL RETURN DUCT CONNECTION AHU-02: SIDE PANEL RETURN GRILLE CONNECTION BUILDING ENVELOPE (#105 & #108-112): NEEDS HVAC WITH/HEAT PUMP OR FURNACE SETPOINTS: WINTER (68°F) AND SUMMER (76°F) ROOM 2O1-202: EXISTING SPLIT HEAT PUMP SYSTEM RELOCATE AHU FROM WAREHOUSE TO ROOM 202 OR INSTALL APPROVED EQUIVALENT ROOM 201 HAS EXISTING SPLIT HEAT PUMP HVAC; RELOCATE EXISTING AHU INTO ROOM 201 MECHANICAL CONTRACTOR WILL DESIGN HVAC TEMP. AND HUM. CTRL. FOR UNCONDITIONED AREAS MECHANICAL CONTRACTOR WILL DESIGN VENTILATION FOR ROOM 103 MECHANICAL CONTRACTOR WILL INSTALL INTAKE GRILLES W/BACKDRAFT DAMPER FOR ROOM 101 & 102
DH-01-4
(TYP. OF ALL)
2'-0"
· · ·
5
trimming, pack & label 111
(TYP. OF 3)
4
NOTES:
EV-02-2
2'-0"
HP-01-5
23'-10"
open area 112
fan-01-1
14
shipping & receiving
unisex toliet 103
unisex changing room 102
cannabis waste secure storage 301
906 S. MAGNOLIA ST. McCOMB, MS, 39648
9
DH-01-1
DRYING 106
MECHANICAL PLAN
13.
FOR TYP. HVAC LAYOUT SEE FLOWERING ROOM 113
5'-10"
EV-02-1
CROWN - 906 S. MAGNOLIA - CANNABIS FACILITY
12.
114
6"
11.
113
22 IN. Ø
10.
flowering
11'-10"
8. 9.
36'-0"
7.
flowering
vestibule 101
115
2'-0" 2'-0"
6.
11
DH-01-2
14 IN. Ø
5.
5'-10"
cultivation activity: dried cannabis curing & storage 107
12
8'-1"
3. 4.
EV-01
9'-7"
2.
13
8'-6"
36" X 6" SPIRAL RETURN DUCT GRILLE (HART & COOLEY “USV/1/36X6/W” OR EQUIV. W/SIMILAR ENGINEER. SPECS) [OWNER SUPPLIED] FABRIC-AIR ROUND FABRIC DUCT AND HARDWARE CD-01 [OWNER SUPPLIED] SPIRAL METAL RETURN DUCT [OWNER SUPPLIED] SPIRAL METAL DUCT FOR SUPPLY CONNECTION TO FABRIC DUCT CEILING HUNG DEHUMIDIFIER (QUEST “225”) [OWNER SUPPLIED] FLOOR MOUNTED VAR. SPEED 4 TON VERTICAL UP-FLOW AHU (GOODMAN “AVPTC49D14”) [OWNER SUPPLIED] GROUND MOUNTED 3.5 TON HEAT PUMP W/10KW HEAT STRIP (GOODMAN “GSZ160421”) INCL. LINE SET [OWNER SUPPLIED] REQUIRED MAINTENANCE CLEARANCE GROUND MOUNTED 2 TON MINI-SPLIT PUMP CD-02 CONDENSER (DAIKIN) [OWNER SUPPLIED] WALL MOUNTED MINI-SPLIT EVAPORATOR (DAIKIN) AT LEAST 6' FROM FLOOR [OWNER SUPPLIED] GROUND MOUNTED 0.75 TON MINI-SPLIT HEAT PUMP CONDENSER (DAIKIN) INCL. LINE SET [OWNER SUPPLIED] WALL MOUNTED 0.75 TON MINI-SPLIT EVAPORATOR (DAIKIN) AT LEAST 7' FROM FLOOR [OWNER SUPPLIED] ROOF JOIST HUNG DEHUMIDIFIER (QUEST “70”) [OWNER SUPPLIED]; 8" SPIRAL METAL DUCT ELBOW SUPPLY AND RETURN ROOM 101 AND 102 VENTILATION EXHAUST 200 CFM IN-LINE HEPA FILTER BOX (HVACQuick “CFB-HP”) W/CENTIF. FAN (FANTEK “FG 6”); 6" SPRIAL DUCT, HORIZONTAL INSTALLATION ON TOP OF ROOMS’ CEILING [OWNER SUPPLIED]
laboratory 110
1'-0"
1.
secure wire room: chemical storage 108 OH-02
13'-6"
KEYNOTE TYPE: FLOOR PLAN ROOMS, AREAS, AND ELEMENTS
8'-6"
X
9'-5"
KEYNOTES:
1 M302
THIS DRAWING IS AN INSTRUMENT OF SERVICE AND AS SUCH SHALL REMAIN THE PROPERTY OF
TRBDESIGNCONSULTANT UNAUTHORIZEDUSEORREPRODUCTIONWITHOUT
PERMISSION OF THE ARCHITECT IS PROHIBITED. THIS DRAWING IS ONLY FOR USE IN CONNECTION WITHTHIS
PROJECTANDSHALLNOTBEUSED FOROTHERLOCATIONS.COPYRIGHT2015
HP-01-1
7 (TYP. OF ALL)
unisex toliet 202
,
T.R. BADGER-ARCHITECUTURAL/ENGINEERINGDESIGNERTRBDESIGNCONSULTANT
CONSULTANT CROWNCANNABIS FACILITY
office 201
TB.DWG
NORTH
MECHANICAL PLAN
1/4" = 1'-0"
Date: OCTOBER/2022 Job No: Project Mgr: TR Badger Drawn By: Checked By: -
M101
N KEYNOTES: KEYNOTE TYPE: FLOOR PLAN ROOMS, AREAS, AND ELEMENTS
X 1. 2. 3. 4. 5.
1
3
1
1
2
3
2. THE VIDEO SURVEILLANCE SYSTEM SHALL EFFECTIVELY AND EFFICIENTLY RECORD IMAGES OF THE AREAS UNDER SURVEILLANCE WITH A MINIMUM OF 720P RESOLUTION. EACH CAMERA WILL BE PERMANENTLY MOUNTED AND IN A FIXED LOCATION. CAMERA LOCATIONS WILL ENSURE THE CLEAR AND CERTAIN IDENTIFICATION OF ANY PERSON, INCLUDING FACIAL FEATURES, AND THEIR ACTIVITIES IN ALL AREAS WHERE RECORDING IS REQUIRED. ALL CAMERAS WILL BE INCLUDED HIGH LIGHT, LOW LIGHT, AND MOTION DETECTION CAPABILITIES AND SHALL RECORD IMAGES THAT CLEARLY AND ACCURATELY DISPLAY THE TIME AND ATE WITHOUT SIGNIFICANTLY OBSCURING THE PICTURE. THE COMPANY WILL INSTALL AND MAINTAIN SUFFICIENT LIGHTING TO MEET THE VIDEO SURVEILLANCE SYSTEM REQUIREMENTS OF 15 MISS. CODE R. § 22-5-10.6, § 22-5-1-10.8, AND THE PLAN DESCRIBED HEREIN.
2
4
KEYNOTE TYPE: MECHANICAL AND ELECTRONIC DOOR LOCKS
COMMERCIAL-GRADE ELECTRONIC DOOR LOCK COMMERCIAL-GRADE MECHANICAL CYLINDER DOOR LOCK COMMERICAL-GRADE MECHANICAL CYLINDER GATE LOCK COMMERCIAL-GRADE MECHANICAL LATCH ROLL-UP DOOR LOCK COMMERICAL-GRADE MECHANICAL LATCH GATE LOCK
2
1
2
3
4
3
2
4
2 3 4
LEGEND: ALARM & SURVEILLANCE ALARM SYSTEM CONTROL KEYPAD
3
4
ALARM SYSTEM MAGNETIC DOOR CONTACT SWITCH
3. THE VIDEO SURVEILLANCE SYSTEM SHALL PROVIDE CONTINUOUS, UNINTERRUPTED COVERAGE OF SECURITY ROOM(S), ROOMS WITH EXTERIOR WALLS, AREAS STORING A SURVEILLANCE SYSTEM STORAGE DEVICE AND THOSE AREAS' ACCESS POINTS, ANY ROOM CONTAINING CANNABIS AND CANNABIS WASTE, ANY ROOM USED FOR CANNABIS CULTIVATION ACTIVITIES OF ANY TYPE, AND CLEARLY RECORD ACTIVITY OCCURRING WITHIN 20 FEET OF ALL POINTS OF INGRESS AND EGRESS TO THE COMPANY'S FACILITY (I.E., DOORWAYS, LOADING AREAS, AND PARKING AREAS) FROM BOTH INDOOR AND OUTDOOR VANTAGE POINTS. THE VIDEO SURVEILLANCE SYSTEM WILL INCLUDE ON-SITE AND OFF-SITE MONITORING CAPABILITIES FOR ALL REAL-TIME AND ARCHIVED VIDEO RECORDINGS, INCLUDING UNFETTERED MONITORY ACCESS PROVIDED TO RELEVANT INSPECTORS AND AGENTS OF THE STATE OF MISSISSIPPI. ALL SURVEILLANCE RECORDINGS WILL BE ARCHIVED DIGITALLY AND STORED ON-SITE FOR A MINIMUM OF 120 DAYS. THE PHYSICAL MEDIA OR STORAGE DEVICE USED TO STORE SURVEILLANCE RECORDINGS IS TO BE SECURED TO PROTECT THE RECORDING FROM TAMPERING OR THEFT. UPS POWER BACKUP DEVICE(S) AND ELECTRIC GENERATOR(S) WILL ENSURE UNINTERRUPTED VIDEO SURVEILLANCE, MONITORING, RECORDING, AND STORAGE CAPABILITIES IN THE EVENT OF A POWER SOURCE FAILURE (POWER OUTAGE). AND A FAILURE NOTIFICATION SYSTEM WILL AUTOMATICALLY NOTIFY THE COMPANY OF ANY INTERRUPTION OR FAILURE OF THE VIDEO SURVEILLANCE SYSTEM OR STORAGE DEVICE(S).
ALARM SYSTEM MOTION DETECTOR C
SURVEILLANCE CAMERA (720p RESOLUTION)
2
V
SURVEILLANCE VIDEO DIGITAL ARCHIVE DEVICE COLOR PRINTER VIDEO MONITOR
3
DIGITAL ARCHIVE DEVICE SECURITY CAGE OUTDOOR FLOOD LIGHT
2
UNINTERRUPTIBLE POWER SUPPLY (UPS) BATTERY BACKUP
2
2
4
1
2
4
NOTES: LOCK, ALARM, & SURVEILLANCE · APPLICANT’S SECURITY PLAN MEETS OR EXCEEDS 15 MISS. CODE R. § 22-5-1.10.5, § 22-5-1.10.6, § 22-5-1.10.7, AND § 22-5-1.10.8
1
2
3
4 2
· REFER TO APPLICANT’S SECURITY OPERATING PLAN FOR SECURITY PLAN AND SYSTEM SPECIFICS
8
· THE EXTERIOR WIRE SECURITY ROOM AND PARKING AREA PERIMETER SECURITY FENCE ARE COVERED WITH PRIVACY SCREEN
9
1
6
4
1
6
4. THE COMPANY WILL MAINTAIN A VIDEO SURVEILLANCE RECORDING LOG. THE LOG WILL INCLUDE THE IDENTITIES OF ANY A CONTRACTOR SERVICING THE VIDEO SURVEILLANCE SYSTEM WITH THE DATE OF TIME OF SERVICE. THE IDENTITY OF THE COMPANY EMPLOYEE(S) RESPONSIBLE FOR MONITORING THE VIDEO SURVEILLANCE SYSTEM. THE IDENTITY OF ANY EMPLOYEE, STATE AGENT, OR STATE INSPECTOR REMOVING A RECORDING FROM A VIDEO SURVEILLANCE STORAGE DEVICE, INCLUDING THE TIME AND DATE OF REMOVAL. AND THE IDENTITY OF THE EMPLOYEE(S) WHO DESTROYED ANY RECORDING, INCLUDING THE TIME AND DATE.
906 S. MAGNOLIA ST. McCOMB, MS, 39648
1. 2.
SECURITY PLAN
ROOM OR AREA WITH EXTERIOR WALLS ROOM OR AREA CONTAINING CANNABIS (OF ANY TYPE OR STAGE OF GROWTH) 3. ROOM OR AREA USED FOR CANNABIS CULTIVATION ACTIVITIES OF ANY TYPE 4. RESTRICTED AREA 5. ROOM OR AREA STORING A SURVEILLANCE SYSTEM STORAGE DEVICE 6. POINTS OF INGRESS AND/OR EGRESS TO THE FACILITY 7. ACCESS POINTS OF ROOM OR AREA STORING A SURVEILLANCE SYSTEM STORAGE DEVICE 8. UNISEX TOILET ROOM 9. UNISEX CHANGING ROOM 10. FENCED PARKING AREA
1. THE COMPANY WILL RETAIN A PROFESSIONAL SECURITY AND VIDEO SURVEILLANCE COMPANY TO PLAN, INSTALL, AND PROVIDE A VIDEO SURVEILLANCE SYSTEM WITH CONTINUOUSLY UNINTERRUPTED VIDEO SURVEILLANCE CAPABILITIES. THE VIDEO SURVEILLANCE SYSTEM, AT A MINIMUM, WILL CONSIST OF DIGITAL OR NETWORK VIDEO RECORDERS, CAMERA CAPABLE OF MEETING THE RECORDING REQUIREMENTS OF 15 MISS. CODE R. § 22-5-1-.10.8 AND THOSE DESCRIBED HEREIN, CONTINUALLY CONNECTED VIDEO MONITOR(S) OF AT LEAST 36-INCHES, DIGITAL ARCHIVING DEVICES, AND A COLOR PRINTER CAPABLE OF DELIVERING STILL PHOTOS.
CROWN - 906 S. MAGNOLIA - CANNABIS FACILITY
X
KEYNOTES:
THIS DRAWING IS AN INSTRUMENT OF SERVICE AND AS SUCH SHALL REMAIN THE PROPERTY OF
TRBDESIGNCONSULTANT UNAUTHORIZEDUSEORREPRODUCTIONWITHOUT
PERMISSION OF THE ARCHITECT IS PROHIBITED. THIS DRAWING IS ONLY FOR USE IN CONNECTION WITHTHIS
PROJECTANDSHALLNOTBEUSED FOROTHERLOCATIONS.COPYRIGHT2015
1
2
4
8
CONSULTANT
1 3
CROWNCANNABIS FACILITY
6
5
1
10
TB.DWG
,
T.R. BADGER-ARCHITECUTURAL/ENGINEERINGDESIGNERTRBDESIGNCONSULTANT
7
color printer C
monitor
monitor
V
NORTH
SECURITY PLAN
1/4" = 1'-0"
Date: OCTOBER/2022 Job No: Project Mgr: TR Badger Drawn By: Checked By: -
S101
N
ROOF
T.O. ROOF 14'-4" WIRED SECURITY ROOM
CORRUGATED STEEL METAL WALL CORRUGATED STEEL METAL WALL
FIN. FLR. 0'-0"
FIN. FLR. 0'-0"
SOUTH ELEVATION
1/4" = 1'-0"
ROOF
T.O. ROOF 14'-4"
ROOF
CROWN - 906 S. MAGNOLIA - CANNABIS FACILITY
HDR.. 9'-6"
906 S. MAGNOLIA ST. McCOMB, MS, 39648
T.O. ROOF. 12'-0"
ELEVATIONS
T.O. ROOF 11'-9"
T.O. ROOF. 14'-4"
T.O. ROOF 9'-6" THIS DRAWING IS AN INSTRUMENT OF SERVICE AND AS SUCH SHALL REMAIN THE PROPERTY OF
TRBDESIGNCONSULTANT UNAUTHORIZEDUSEORREPRODUCTIONWITHOUT
CORRUGATED STEEL METAL WALL
PERMISSION OF THE ARCHITECT IS PROHIBITED. THIS DRAWING IS ONLY FOR USE IN CONNECTION WITHTHIS
CORRUGATED STEEL METAL WALL
PROJECTANDSHALLNOTBEUSED FOROTHERLOCATIONS.COPYRIGHT2015
,
T.R. BADGER-ARCHITECUTURAL/ENGINEERINGDESIGNERTRBDESIGNCONSULTANT
CONSULTANT CROWNCANNABIS FACILITY
FIN. FLR. 0'-0"
FIN. FLR. 0'-0"
TB.DWG
Date: OCTOBER/2022 Job No: Project Mgr: TR Badger Drawn By: Checked By: -
WEST ELEVATION
1/4" = 1'-0"
S102
N
FIN. FLR. 0'-0"
NORTH ELEVATION
1/4" = 1'-0"
ROOF
T.O. ROOF 14'-4"
906 S. MAGNOLIA ST. McCOMB, MS, 39648
CORRUGATED STEEL METAL WALL
ELEVATIONS
T.O. ROOF 14'-4"
CROWN - 906 S. MAGNOLIA - CANNABIS FACILITY
ROOF
T.O. ROOF. 14'-4"
T.O. ROOF 10'-0" THIS DRAWING IS AN INSTRUMENT OF SERVICE AND AS SUCH SHALL REMAIN THE PROPERTY OF
CORRUGATED STEEL METAL WALL
HDR. 6'-10"
TRBDESIGNCONSULTANT UNAUTHORIZEDUSEORREPRODUCTIONWITHOUT
PERMISSION OF THE ARCHITECT IS PROHIBITED. THIS DRAWING IS ONLY FOR USE IN CONNECTION WITHTHIS
PROJECTANDSHALLNOTBEUSED FOROTHERLOCATIONS.COPYRIGHT2015
,
T.R. BADGER-ARCHITECUTURAL/ENGINEERINGDESIGNERTRBDESIGNCONSULTANT
CORRUGATED STEEL METAL WALL
CONSULTANT CROWNCANNABIS FACILITY
FIN. FLR. 0'-0"
FIN. FLR. 0'-0"
TB.DWG
Date: OCTOBER/2022 Job No: Project Mgr: TR Badger Drawn By: Checked By: -
EAST ELEVATION
1/4" = 1'-0"
S103
N
NORTH T.O. ROOF 14'-4"
office
FIN. FLR. 0'-0"
FIN. FLR. 0'-0"
SECTION A
1/4" = 1'-0"
NORTH T.O. ROOF 14'-4"
906 S. MAGNOLIA ST. McCOMB, MS, 39648
cultivation activity: propagation & vegetative growth phases
SECTIONS
cultivation activity: generative growth phase room #1
CROWN - 906 S. MAGNOLIA - CANNABIS FACILITY
T.O. ROOF. 14'-4"
T.O. ROOF. 14'-4"
T.O. ROOF 10'-0" THIS DRAWING IS AN INSTRUMENT OF SERVICE AND AS SUCH SHALL REMAIN THE PROPERTY OF
TRBDESIGNCONSULTANT UNAUTHORIZEDUSEORREPRODUCTIONWITHOUT
cultivation activity: generative growth phase room #2
hallway
PERMISSION OF THE ARCHITECT IS PROHIBITED. THIS DRAWING IS ONLY FOR USE IN CONNECTION WITHTHIS
PROJECTANDSHALLNOTBEUSED FOROTHERLOCATIONS.COPYRIGHT2015
,
T.R. BADGER-ARCHITECUTURAL/ENGINEERINGDESIGNERTRBDESIGNCONSULTANT
CONSULTANT CROWNCANNABIS FACILITY
FIN. FLR. 0'-0"
FIN. FLR. 0'-0"
TB.DWG
Date: OCTOBER/2022 Job No: Project Mgr: TR Badger Drawn By: Checked By: -
SECTION B
1/4" = 1'-0"
S104
N
cultivation activity: generative growth phase room #2
FIN. FLR. 0'-0"
SECTION C
1/4" = 1'-0"
906 S. MAGNOLIA ST. McCOMB, MS, 39648
cultivation activity: generative growth phase room #1
SECTIONS
cultivation activity: harvesting and drying
cultivation activity: harvest batch trimming, packaging and labeling
CROWN - 906 S. MAGNOLIA - CANNABIS FACILITY
T.O. ROOF 14'-4"
THIS DRAWING IS AN INSTRUMENT OF SERVICE AND AS SUCH SHALL REMAIN THE PROPERTY OF
TRBDESIGNCONSULTANT UNAUTHORIZEDUSEORREPRODUCTIONWITHOUT
PERMISSION OF THE ARCHITECT IS PROHIBITED. THIS DRAWING IS ONLY FOR USE IN CONNECTION WITHTHIS
PROJECTANDSHALLNOTBEUSED FOROTHERLOCATIONS.COPYRIGHT2015
,
T.R. BADGER-ARCHITECUTURAL/ENGINEERINGDESIGNERTRBDESIGNCONSULTANT
CONSULTANT CROWNCANNABIS FACILITY
TB.DWG
Date: OCTOBER/2022 Job No: Project Mgr: TR Badger Drawn By: Checked By: -
1/4" = 1'-0"
S105
MECHANICAL CODE (2015) NATIONAL ELECTRICAL CODE (NEC 2017) PLUMBING CODE (2015) ENERGY CODE (2015)
INTERIOR FINISHES SHALL COMPLY WITH CHAPTER 8 OF THE INTERNATIONAL BUILDING CODE.
SECTION 702.2-702.5
NOT APPLICABLE
SECTION 702.6
MATERIALS AND METHODS: PROJECT TO COMPLY
SECTION 702.6.1
INTERNATIONAL FUEL GAS CODE: PROJECT TO COMPLY
NFPA 101 - FIRE CODE 2016
SECTION 703.1
FIRE PROTECTION PROJECT TO COMPLY
INTERNATIONAL FIRE CODE (IFC 2015)
SECTION 704.1
MEANS OF EGRESS: PROJECT WILL COMPLY WITH (2015)
SECTION 705.1
ACCESSIBILITY: NOT APPLICABLE - PROJECT AREA IS CURRENTLY NOT ACCESSIBLE.
SECTION 706
REROOFING
SECTION 707
STRUCTURAL
SECTION 708
ENERGY CONSERVATION: EXTERIOR RENOVATIONS
BUILDING CODE SUMMARY (PER 2015 BUILDING CODE) F-1 FACTORY INDUSTRIAL MODERATE HAZARD-HEMP PRODUCTS
BUILDING OCCUPANCY:
CHAPTER 3 - USE & OCCUPANCY ALTERATIONS LEVEL 2:
(SECTION 504)
LEVEL 2 ALTERNATIONS SHALL COMPLY WITH CHAPTERS 7 & 8 OF THE REHAB CODE. CHANGE OF OCCUPANCY:
(REQUIRED FOR LEVEL 2 ALTERATIONS) (PER 2015 REHAB CODE) SECTION 802
SPECIAL USE AND OCCUPANCY: NOT APPLICABLE
SECTION 803.1-803.2
NOT APPLICABLE
SECTION 803.4
INTERIOR FINISHES: SHALL COMPLY WITH CHAPTER 8 OF THE INTERNATIONAL BUILDING CODE.
SECTION 803.5
GUARDS: SHALL COMPLY WITH (2015)
SECTION 803.6
FIRE-RESISTANCE RATINGS.
SECTION 804.1.1
CORRIDOR RATINGS: SHALL COMPLY WITH (2015).
SECTION 804.2-804.3
AUTOMATIC SPRINKLER SYSTEM.
SECTION 804.4
FIRE ALARM AND DETECTION: A FULL FIRE ALARM SYSTEM NOT REQUIRED IN USE GROUP F-1 UNLESS 2 OR MORE STORIES IN HEIGHT PER (2015) SECTION 907.2.4
CHAPTER 5 - CLASSIFICATION OF WORK (PER 2015 BUILDING CODE) NO INCREASE IN EXISTING BUILDING HEIGHT OR AREA IS PLANNED. (EXISTING BUILDING HEIGHT AT THIS TENANT SPACE IS FROM THE FLOOR LINE - GRADE VARIES) EXISTING BUILDING HAS AN AUTOMATIC SPRINKLER SYSTEM.
SECTION 805-805.8
MEANS OF EGRESS: PROTECT WILL COMPLY WITH (2015).
SECTION 805.9
HANDRAILS: STAIRS SHALL COMPLY WITH (2015)
SECTION 805.10
REFUGE AREAS: NOT APPLICABLE.
CHAPTER 5 - GENERAL BUILDING AREAS
SECTION 805.11
GUARDS: SHALL COMPLY WITH (2015)
SECTION 806
ACCESSIBILITY: PROJECT SHALL COMPLY WITH SECTION 410.8.1 ENTRANCES. ACCESSIBILITY ENTRANCE SHALL BE PROVIDED PER SECTION 1105 OF (2015). SECTION 1105.1.6 TENANT SPACE - NEW ACCESSIBLE ENTRANCE SHALL BE PROVIDED. NOTE - THAT THIS IS ALSO THE PUBLIC ENTRANCE. PROJECT AREA INTERIOR SHALL COMPLY WITH (2015) CHAPTER 11 FOR ACCESSIBILITY.
(PER 2015 BUILDING CODE) CONSTRUCTION CLASSIFICATION: (SECTION 602.2)
TYPE II-B-UNPROTECTED STEEL FRAME
FIRE RESISTANCE RATING FOR BUILDING ELEMENTS: (TABLE 601)
0 HOURS
FIRE RESISTANCE RATING FOR EXTERIOR WALLS BASED ON FIRE SEPARATION DISTANCE (TABLE 602).
SECTION 807.2
0 HOURS FOR USE GROUP F-1, TYPE OF CONSTRUCTION IIB AND 10' TO 30' FIRE SEPARATION DISTANCE.
NEW STRUCTURAL ELEMENTS. SHALL COMPLY WITH INTERNATIONAL BUILDING CODE.
SECTION 807.4-807.5
EXISTING STRUCTURAL ELEMENTS; ELEMENTS THAT ARE ALTERED SHALL COMPLY WITH THESE SECTIONS. ELECTRICAL NEW INSTALLATIONS: PROJECT SHALL COMPLY.
SECTION 808.1
CHAPTER 6 - TYPE OF CONSTRUCTION
SECTION 808.2
AUTOMATIC SPRINKLER SYSTEMS: (SECTION 903) THE EXISTING BUILDING CONSTRUCTION IS NOT SUPPRESSED
ELECTRICAL EXISTING INSTALLATIONS: NOT APPLICABLE.
SECTION 808.3-808.3.7 NOT APPLICABLE SECTION 809.1-809.3
MECHANICAL: PROJECT SHALL COMPLY.
SECTION 810.1
PLUMBING MINIMUM FIXTURES: PLUMBING FIXTURE COUNT SHALL COMPLY WITH (2015).
CHAPTER 9 - FIRE PROTECTION SYSTEMS
SECTION 811
ENERGY CONSERVATION: NOT APPLICABLE - NO EXTERIOR RENOVATIONS.
(PER 2015 BUILDING CODE)
NOTE THAT PER OWNER AFFIDAVIT THE TOTAL NUMBER OF OCCUPANTS IN THE FACILITY IS LESS THAN 15 IN PHASE 1. THEREFORE, ONE UNI-SEX ACCESSIBLE TOILET ROOM IS REQUIRED PER SECTION 403.2 OF THE (2015).
2 INCHES x 42 OCCUPANTS=
9 INCHES REQUIRED 32 INCHES REQUIRED (1 EXIT DOOR AT 32" CLEAR OPENING)
COMMON PATH OF EGRESS TRAVEL AND EXIT ACCESS TRAVEL DISTANCE (TABLES 1006.2.1 AND 1017.2) REFER TO FLOOR PLAN DRAWING THIS SHEET FORD DISTANCES. CORRIDOR FIRE RESISTANCE RATING (TABLE 1020.1) 0 HOUR RATING REQUIRED IN USE GROUP F
CHAPTER 29 - PLUMBING
CLIMATE ZONE NO EXTERIOR RENOVATIONS PROPOSED. ONLY ONE NEW OPAQUE EXIT DOOR PROPOSED. BUILDING ELEMENT OPAQUE DOORS - SWINGING
MIN. R-VALUE OF INSULATION OF ASSEMBLY U-VALUE U-0.500
ENERGY CODE 2015 AND ASHRAE STD. 90.1-2013 NFPA 101 - LIFE SAFETY CODE (2018) SECTION 6.1.12.1
INDUSTRIAL OCCUPANCY (PROCESSING & GROWING)
TABLE 6.1.14.4.1 (b)
NO SEPARATION REQUIRED BETWEEN PROPOSED NEW AREA AND GROW AREA AS BOTH ARE CLASSIFIED AS INDUSTRIAL, GENERAL PURPOSE.
CHAPTER 6 - CLASSIFICATION OF OCCUPANCY SECTION 40.1.7
OCCUPANT LOAD- PER TABLE 7.3.1.2, 100 SF/OCCUPANCY MATCHES (2015) REQUIREMENTS (OCCUPANTS BASED ON AREA).
TABLE 40.2.5.1 & TABLE 40.2.6.1
ARRANGEMENT OF MEANS OF EGRESS: MATCHES (2015) REQUIREMENTS FOR COMMON PATH OF TRAVEL AND MAXIMUM TRAVEL DISTANCE.
SECTION 40.2.8
ILLUMINATION OF MEANS OF EGRESS SHALL BE IN ACCORDANCE WITH SECTION 7.8
SECTION 40.2.9
EMERGENCY LIGHTING SHALL BE IN ACCORDANCE WITH SECTION 7.9.
SECTION 40.3.3.2
INTERIOR WALL AND CEILING FINISHES SHALL BE CLASS A, B OR C IN OPERATING AREAS AND PER SECTION 7.1.4 IN EXIT ENCLOSURES (CLASS A OR B).
SECTION 40.3.4
A FIRE ALARM SHALL BE REQUIRED FOR OCCUPANT LOADS OF 100 OR MORE PER REQUIREMENTS OF SECTIONS 9.6, 40.3.4.2 AND 40.3.4.3.
SECTION 38.5.3
THE USE OF OZONE GENERATORS USED FOR ODOR CONTROL SHALL COMPLY WITH CHAPTER 54. INTERIOR FINISH, INCLUDING THE USE OF PLASTIC, MYLAR OR OTHER THIN FILM SHEETING TO COVER WALLS OR CEILINGS SHALL BE IN ACCORDANCE WITH SECTIONS 12.5 AND 12.8.
CHAPTER 38- MARIJUANA GROWING, PROCESSING OR EXTRACTION FACILITIES
SECTION 1003
BUILDING ELEMENTS AND MATERIALS: NOT APPLICABLE - NO CHANGES IN OCCUPANCY CLASSIFICATION.
SECTION 908.7
SECTION 1004
FIRE PROTECTION: NOT APPLICABLE - NO CHANGE IN OCCUPANCY CLASSIFICATION.
CARBON DIOXIDE SYSTEMS - EMERGENCY ALARM SYSTEM IN ACCORDANCE WITH SECTION 5397.5.2 SHALL BE PROVIDED.
SECTION 5307.5.2
EMERGENCY ALARM SYSTEM
SECTION 1005
MEANS OF EGRESS: NOT APPLICABLE - NO CHANGE IN OCCUPANCY CLASSIFICATION (SEE CHAPTER 8 FOR REQUIREMENTS).
SECTION 1007
STRUCTURAL: NOT APPLICABLE - NO CHANGE IN OCCUPANCY CLASSIFICATION. ELECTRICAL: NOT APPLICABLE - NO CHANGE TO SPECIAL OCCUPANCY. MECHANICAL: NEW MECHANICAL SYSTEMS SHALL COMPLY WITH (2015).
FLAMMABLE AND COMBUSTIBLE LIQUIDS
CONTAINER TYPE CLASS
TOTAL GALLONS
MAQ GALLONS
IB
480
IIIA
1320
MAXIMUM ALLOWABLE QUANTITIES (MAQ's) OF HAZARDOUS MATERIALS PER CONTROL AREA PER MBC TABLE 307.1 (1). NOTE THAT GROWER AREA CONSTITUTES ONE CONTROL AREA. MAQ's INDICATED ARE BASED ON TABLE 307.1 (1) FOOTNOTES: a. 100% INCREASE IN MAQ"s WHEN STORED IN APPROVED CONTAINERS. MAQ's ARE NOTE EXCEEDED, THEREFORE ENTIRE FACILITY IS CLASSIFIED AS F-1 (FACTORY - MODERATE HAZARD) USE GROUP PER 2015 (NO "H" USE GROUP DESIGNATION).
CHAPTER 40 - INDUSTRIAL OCCUPANCIES
SPECIAL USE AND OCCUPANCY: NOT APPLICABLE - NO SPECIAL USES.
SECTION 1009
QUANTITY
BUILDING DESIGNATED AS NON-RESIDENTIAL
SECTION 1002
SECTION 1008
1.
4.
(REQUIRED FOR LEVEL 2 ALTERATIONS) (PER 2015 REHAB CODE)
REQUIRED EGRESS CAPACITY BASED ON OCCUPANT LOAD (SECTION 1005.3.2)
COMBUSTIBLE LIQUID CLASS II, IIIA & IIIB
NOTES: 2. 3.
NOTE THAT PER OWNER AFFIDAVIT OCCUPANT LOAD IN FACILITY SHALL BE NO MORE THAN 15 OCCUPANTS.
CHANGE OF USE, PROJECT FALLS WITHIN THIS CLASSIFICATION. PREVIOUS USE WAS ALSO F-1 SO THERE IS NO CHANGE IN OCCUPANCY CLASSIFICATION. PROJECT TO COMPLY WITH SECTIONS 1002 THROUGH 1011.
FLAMMABLE LIQUID CLASS 1A, IB & IC
PLUMBING SYSTEMS SCOPE - SECTION 2901.1 PLUMBING SYSTEMS AND EQUIPMENT SHALL BE CONSTRUCTED, INSTALLED AND MAINTAINED IN ACCORDANCE WITH THE MICHIGAN PLUMBING CODE.
CHAPTER 8 - ALTERATION LEVEL 2 SECTION 1001.2.1
PRODUCT
GROWER
(PER 2015 REHAB CODE)
SECTION 38.5.2
1 OCCUPANT/100 GROSS S.F. 4,260 SF/100 = 43 OCCUPANTS
GROWER
CHAPTER 10 - CHANGE OF OCCUPANCY
OCCUPANT LOAD: (PROPOSED OCCUPANTS FOR EGRESS PURPOSES) (PER TABLE 1004.1.2)
F-1 (INDUSTRIAL AREAS)
TB.DWG
LIGHT AND VENTILATION: NEW SYSTEMS SHALL COMPLY WITH 2015 BUILDING AND MECHANICAL CODES.
CHAPTER 7 - ALTERATION LEVEL 1
(SECTION 506)
CHANGE OF OCCUPANCY SHALL COMPLY WITH CHAPTER 10 OF THE REHAB CODE.
SECTION 1011
N
HAZARDOUS MATERIALS - TYPES AND QUANTITIES
906 S. MAGNOLIA ST. McCOMB, MS, 39648
SECTION 702.1
PLUMBING: NEW PLUMBING SYSTEM SHALL COMPLY WITH (2015).
INFORMATION NOTES
REHABILITATION COD FOR EXISTING BUILDINGS (2015)
SECTION 1010
CROWN - 906 S. MAGNOLIA - CANNABIS FACILITY
BUILDING CODE 2015
(REQUIRED FOR LEVEL 2 ALTERATIONS) (PER 2015 REHAB CODE)
AN EMERGENCY ALARM SYSTEM SHALL COMPLY WITH ALL OF THE FOLLOWING: 1. CONTINUOUS GAS DETECTION SHALL BE PROVIDED TO MONITOR AREAS WHERE CARBON DIOXIDE CAN ACCUMULATE. 2. THE THRESHOLD FOR ACTIVATION OF AN ALARM SHALL NOT EXCEED 5,000 PARTS PER MILLION (9,000 mg/m2) 3. ACTIVATION OF THE EMERGENCY ALARM SYSTEM SHALL INITIATE A LOCAL ALARM WITHIN THE ROOM OR AREA IN WHICH THE SYSTEM IS INSTALLED.
CHAPTER 10 - MEANS OF EGRESS CHAPTER 10 - CHANGE OF OCCUPANCY INTERNATIONAL FIRE CODE (2015)
THIS DRAWING IS AN INSTRUMENT OF SERVICE AND AS SUCH SHALL REMAIN THE PROPERTY OF
TRBDESIGNCONSULTANT UNAUTHORIZEDUSEORREPRODUCTIONWITHOUT
PERMISSION OF THE ARCHITECT IS PROHIBITED. THIS DRAWING IS ONLY FOR USE IN CONNECTION WITHTHIS
PROJECTANDSHALLNOTBEUSED FOROTHERLOCATIONS.COPYRIGHT2015
,
T.R. BADGER-ARCHITECUTURAL/ENGINEERINGDESIGNERTRBDESIGNCONSULTANT
CONSULTANT CROWNCANNABIS FACILITY
Date: OCTOBER/2022 Job No: Project Mgr: TR Badger Drawn By: Checked By: -
N101