REFLECTINGCEILINGPLAN
LIGHTINGFIXTURESCHDULE:
FLUORESCENTFIXTURE,2'x4',LAY-INTYPE,ELECTRONICBALLAST LITHONIA:2GT3-32A1210,3-32W,3T8-32LAMPS,120V
EXITLIGHTWITHBATTERIESBACKUPTOMEETNEPALIFESAFETYCODE.
COMBINATIONEXITANDEMERGENCYLIGHTFIXTURETOMEETNFPA LIFESAFETYCODE.BATTERIESBACKUPTOENSURECONTINUED ILLUMINATIONFORADURATIONOFNOTLESSTHAN90MINUTESPER SECTION1003.2.10.5,IBC2000EDITION.
EMERGENCYLIGHTWITHBATTERIESBACKUP,SEALEDBEAMTOMEET
LIGHTSAFETYCODE.BATTERIESBACKUPTOENSURECONTINUED ILLUMINATIONFORADURATIONOFNOTLESSTHAN90MINUTESPER SECTION1003.2.10.5,IBC2000EDITION.
REMOTEEMERGENCYLIGHTINGHEAD,NEMA3R
KITCHENHOODLIGHT,100W,120V SUPPLIEDBYHOODMANUFACTURER
PANDENTLIGHT
PANDENTLIGHT
RECESSEDLIGHT
SCONELIGHT
WALLMOUNTEDOCCUPANTSENSOR
CEILINGOCCUPANTSENSOR
TIMERCONTROLLER
COMPLIANCEOF2008COMMERCIALENERGYCONSERVATIONCODEOF CITYOFHOUSTON
NIGHTLIGHT
ABOVEFINISHEDFLOOR WEATHERPROOFENCLOSUREORCOVER.
MAINCIRCUITBREAKER MAINLUGSONLY HIGHPOWERFACTOR NEMARATEDENCLOSURE3R:OUTDOORWEATHERPROOF1:INDOOR 3PHASEOR3POLEDEVICE 3WIREDIVICEORSYSTEM
RECESSEDORSURFACEMOUNTFLOURESCENTFIXTURE2'x4'OR2'x2' SURFACEORRECESSTYPE,ELECTRONICBALLAST,120VOR277V SURFACEORCHAINHUNGMOUNT4FEETOR8FEETFLUORESCENT FIXTURE.ENERGYSAVINGBALLAST.
RECESSEDORSURFACEMOUNTEDINCANDESCENTORH.I.D.FIXTURE. SAMEDESIGNATIONSASABOVE. WALLMOUNTEDTOGGLESWITCH,15AMP.,120/277VOLTRATED, MOUNT48"ABOVEFINISHEDFLOOR,COMPLETEWITHSMOOTH PLASTICPLATE.
MOUNTSWITCH,SENTINELTYPEWITHPROPERTHERMALELEMENT INSTALLEDFORMOTORPROTECTION.COMPLETEWITHSMOOTH PLASTICPLATE.
CONDUITANDWIREHOMERUNTOPANELLETTERINDICATEDPANEL& CIRCUITINDICATED,SEEPANELSCHEDULEFORNUMBEROF CONDUCTORSANDANYSPECIALREQUIREMENTS.
SAFETYDISCONNECTSWITCH,HEAVYDUTYTYPE(HD),NEMA(1)FOR INDOORSANDNEMA(3R)FOROURDOORS. EXITLIGHTW/BATTERIESBACKUPTOMEETNFPALIFESAFETY CODE.
COMBINATIONEXITANDEMERGENCYLIGHTFIXTURETOMEETNFPA, LIFESAFETYCODE.BATTERIESBACKUPTOENSURECONTINUED ILLUMINATIONFORADURATIONOFNOTLESSTHAN90MINUTESPER SECTION1003.2.10.5,I.B.C.2000EDITION.
EXHAUSTFAN-MOTORCONNECTION LIGHTINGPANELBOARD.SEESCHEMATICS
TELEPHONEOUTLET.PROVIDEBOXINWALLWITHPULLWIRETOAN ACCESSIBLELOCATIONABOVECEILING. STANDARDDUPLEXOUTLET,20AMPS.,120VOLT,2POLE,3WIRE GROUNDEDTYPE.
QUADRANTOUTLET(2DUPLEXOUTLETGROUNDEDTYPE)20A,120V
STANDARDDUPLEXOUTLET,20AMPS,120V,2POLE,3WWITHGROUND FAULTINTERRUPTERPROTECTION.
STANDARDOUTLET15A,20A,30A.(GROUNDED)208V,240V,SINGLE PHASEOR3PHASE(SEEPANELSCHEDULEFORCONNECTION.)
OCCUPANTSENSOR
TIMERCONTROL NIGHTLIGHT
ROOFTOPUNIT,CONNECTASINDICATED.
PROVIDEAGROUNDFAULTPROTECTEDWEATHERPROOFDUPLEXRECEPTACLEAT CONDENSINGUNITASSHOWNANDREQUIREDBYCODE.
PROVIDEJUNCTIONBOXINWALLANDRUNPULLWIREFORTELEPHONEAND/ORDATA LINEOUTLETTOANACCESSIBLELOCATIONABOVECEILINGLINE.PROVIDE3/4"CONDUIT INCONCRETE,SLABORMASONRYWALL.
300-7N.E.C.RACEWAYSEXPOSEDTODIFFERENTTEMPERATURE(a)SEALING.WHERE PORTIONSOFANINTERIORRACEWAYSYSTEMAREEXPOSEDTOWIDELYDIFFERENT TEMPERATURES,ASINREFRIGERATINGORCOLD-STORAGEPLANTS,CIRCULATIONOFAIR FROMAWARMERTOACOLDERSECTIONTHROUGHTHERACEWAYSHALLBEPREVENTED.
COMPLIANCEOFSECTION510.2.4.2OFTHEUNIFORMMECHCODE.REQUIRESTHATHOOD FIREEXTINGUISHINGSYSTEMSHALLBEINTERCONNECTEDTOFUELORCURRANTSUPPLY SOTHATSUPPLYSOTHATTHEFUELORCURRENTISAUTOMATICALLYSHUTDOWN TOALLEQUIPMENTUNDERTHEHOODWHENTHESYSTEMISACTUATED.
KITCHENHOODEXHAUSTDUCTUPTHRUROOFTOKITCHENHOOD EXHAUSTFANONROOF
KITCHENHOODEXHAUSTDUCTDOWNANDCONNECTTOKITCHENHOOD EXHAUSTCONNECTIONWITHTRANSITION.
INSULATEDSUPPLYDUCTUPTHRUROOFTOSUPPLYFANONROOF OUTDOORAIRINLETSGREATERTHAN300CFMREQUIREMOTORIZEDDAMPERS. PROVIDEAMOTORIZEDDAMPERFORTHEHOOD'SMAKEUPAIRFANSUPPLYFAN.
INSULATEDSUPPLYDUCTCONNECTTOKITCHENHOODSUPPLYCONNECTIONWITH TRANSITIONANDVOLUMEDAMPER.
KITCHENHOOD(19'-0"LONGAND13'-0"LONG)
CEILINGMOUNTTOILETEXHAUSTFAN
RUNFULLSIZEEXHAUSTDUCTTOROOFCAP
DISHWASHERHOOD
DISHWASHERHOODEXHAUSTDUCTCONNECTEDTO DISHWASHERHOODEXHAUSTCONNECTIONWITHTRANSITION. REFERTOCAPITIVEAIREDRAWINGS.
LEGEND:
T THERMOSTATE,MOUNTASSHOWN.
24"x24"AIRSUPPLYDIFFUSERBYTITUS.
24"x24"AIRRETURNGRILLE.
SLOTDIFFUSER
2"GASSERVICEDOWNWITHAUTOGASSHUTOFFVALVE INSTALLEDBELOWCEILING
2"GASMANIFOLD,12"A.F.F. EXISTINGWATERLINE,FIELDVERIFY.
1/2"CUT-FFVALVE
1"CWTOCONNECTTOWATERHEATER
3/4"HW(140°F)OUTTODISHWASHER. 1"HW(120°F)OUTFOROTHERFIXTURES
1/2"CWANDHWDOWNTOSERVEMOPSINK
1/2"CWDOWNTOSERVICESTATION
3/4"CWDOWNTOSERVICEWOKS INSTALLBACKFLOWPREVENTER
1/2"HW&CWTOSERVEHANDSINK
1/2"CWANDHWDOWNTOSERVE3-COMP.SINK
1/2"CW&HWTOSERVESOILTABLE
3/4"HW(140°F)DOWNTOSERVEDISHWASHER
1/2"CWTOSERVEICEMACHING INSTALLBACKFLOWPREVENTERANDWATERFILTER
1/2"CW&HWDOWNTOSERVELAVATORY
1"CWDOWNTOSERVEWATERCLOSET
1/2"CWDOWNTOSERVECOKEMACHINE INSTALLBACKFLOWPREVENTER
3/4"CWDOWNTOSERVEURINAL
NEW4"SEWERCONNECTEDTOEXISTINGSEWER.FIELDVERIFY.
2"UNDERGROUNDVENTLINE(TYP.)
2"UNDERGROUNDVENTLINEUPINWALLANDCONNECTTOVENT.(TYP.)
NEWVENTPIPECONNECTEDTOEXIST.VTR
SANITARYSOILORWASTE
SANITARYVENT
COLDWATER
HOTWATER
GASLINE BALLVALVE
SHUTOFFVALVE
UNION
STRAINER
COTGCLEANOUTTOGRADE PRESSUREGAUGEWITHGAUGECOCK