7317 E. Cypress St. - Existing Site & Floor Plans - Scottsdale, AZ

Page 1


THESCOTTSDALEBUILDINGCONSTRUCTIONCODECONSISTSOFTHE CITYOFSCOTTSDALEADMINISTRATIVEPROVISIONS,THEFOLLOWING CODESANDSTANDARDS,ANDCITYOFSCOTTSDALEAMENDMENTS

THERETO:

2018INTERNATIONALBUILDINGCODE(IBC) 2018INTERNATIONALRESIDENTIALCODE(IRC) 2018INTERNATIONALMECHANICALCODE(IMC) 2018INTERNATIONALPLUMBINGCODE(IPC) 2018UNIFORMPLUMBINGCODE(UPC) 2018INTERNATIONALFUELGASCODE(IFGC) 2018INTERNATIONALENERGYCONSERVATIONCODE(IECC) 2019INTERNATIONALEXISTINGBUILDINGCODE(IEBC) 2012INTERNATIONALGREENCONSTRUCTIONCODE(IGCC) 2017NATIONALELECTRICALCODE(NEC) 2018PHOENIXFIRECODE

CODES

1.DEVELOPMENTANDUSEOFTHISSITEWILLCONFORMTOALLAPPLICABLE CODESANDORDINANCES.

2.ALLNEWORRELOCATEDUTILITIESWILLBEPLACEDUNDERGROUND.

3.STRUCTURESANDLANDSCAPINGWITHINATRIANGLEMEASUREDBACK10 FEETFROMTHEPROPERTYLINEAND20FEETALONGTHEPROPERTYLINEON EACHSIDEOFTHEDRIVEWAYENTRANCESWILLBEMAINTAINEDATAMAXIMUM HEIGHTOF3'-0".

4.OWNERSOFPROPERTYADJACENTTOPUBLICRIGHTOFWAYWILLHAVETHE RESPONSIBILITYFORMAINTAININGALLLANDSCAPINGWITHINTHERIGHTOF WAYINACCORDANCEWITHAPPROVEDPLANS.

4.ANYLIGHTINGWILLBEPLACEDSOASTODIRECTTHELIGHTAWAYFROM ADJACENTRESIDENTIALDISTRICTSANDWILLNOTEXCEEDONEFOOTCANDLE ATTHEPROPERTYLINE.NONOISE,ODORORVIBRATIONWILLBEEMITTEDAT ANYLEVELEXCEEDINGTHEGENERALLEVELOFNOISE,ODORORVIBRATION EMITTEDBYUSESINTHEAREAOUTSIDEOFTHESITE.

6.ALLROOFTOPEQUIPMENTANDSATELLITEDISHESSHALLBESCREENEDTO THEHEIGHTOFTHETALLESTEQUIPMENT.

7.ALLSERVICEAREASSHALLBESCREENEDTOCONCEALTRASHCONTAINERS, LOADINGDOCKS,TRANSFORMERS,BACKFLOWPREVENTOR,ANDOTHER MECHANICALORELECTRICALEQUIPMENTFROMEYELEVELADJACENTTOALL PUBLICSTREETS.

8.THEEXISTINGSTRUCTURESMUSTCOMPLYWITHTHECHANGEOF OCCUPANCYPROVISIONSINTHEPHOENIXCONSTRUCTIONCODEPRIORTO USE.

9.AFTERFINALAPPROVALTHEPROJECTWILLBEINSPECTEDFORZONING COMPLIANCEDURINGCONSTRUCTIONANDPRIORTOOCCUPANCY.THE APPLICANTISTONOTIFYDSDPRIORTOOCCUPANCYTOARRANGEFOR INSPECTIONS.CALL262-6981ANDREQUESTADESIGNREVIEWINSPECTION.

10.BARBED,RAZORORCONCERTINAWIRE(ORSIMILAR)SHALLNOTBEUSED ONTHISSITEWHEREVISIBLEFROMPUBLICSTREETSORADJACENT RESIDENTIALAREAS.

11.ONSITELIGHTINGSHALLNOTEXCEEDONEFC(FOOTCANDLE)ATTHE PROPERTYLINE.

12.MAXIMUMNOISELEVELOF55DECIBELS(NORMALSPEAKINGVOICE)ATTHE PROPERTYLINE.

13.SITELANDSCAPING,WALLSANDLIGHTINGTOMATCHINPHASEDPROJECTS.

14.ALLON-SITEWATERLINES,INCLUDINGTHOSEREQUIREDFORFIRE PROTECTIONSHALLBEPRIVATEPLUMBINGLINESSUBJECTTOTHEPHOENIX PLUMBINGCODE.

15.THEARCHITECTSHALLNOTHAVECONTROLORCHARGEOF,ANDSHALLNOT BERESPONSIBLEFORCONSTRUCTIONMEANS,METHODS,TECHNIQUES, SEQUENCEONPROCEDURES,ORFORSAFETYPRECAUTIONSANDPROGRAMS INCONNECTIONWITHTHEWORK,ALLOFWHICHSHALLBETHESOLE RESPONSIBILITYOFTHECONTRACTOR.

16.THEDESIGN,ADEQUACY,ANDSAFETYOFERECTIONBRACING,SHORING, TEMPORARYSUPPORTS,ETC.,DURINGDEMOLITIONANDCONSTRUCTION,IS THESOLERESPONSIBILITYOFTHECONTRACTOR,ANDHASNOTBEEN CONSIDEREDBYTHESTRUCTURALENGINEER.

17.DISCREPANCIESINTHECONTRACTDOCUMENTS;INTHEEVENTOFERROR, OMISSION,AMBIGUITY,ORCONFLICTWITHINTHEDRAWINGSOR SPECIFICATIONS,THECONTRACTORSHALLBRINGTHEMATTERTOTHE ARCHITECT'SATTENTIONINATIMELYMANNER,FORARCHITECT'S DETERMINATIONANDDIRECTIONINACCORDANCEWITHPROVISIONSOFTHE GENERALCONDITIONS.DISCREPANCIESINTHECONTRACTDOCUMENTSSHALL NOTBEALLOWEDASABASISFORCHANGEORDERS.

18.JOBSITEMEASUREMENTSARETHEFULLRESPONSIBILITYOFTHE CONTRACTORAND/ORSUBCONTRACTORANDMUSTBETAKENFORALLITEMS BYALLSUBCONTRACTORSPRIORTOFABRICATION.

19.THECONTRACTORSHALLBERESPONSIBLEFORINSTALLINGSOLIDBACKING BEHINDALLSHELVING,HANDRAILS,BRACKETS,CABINETS,DOORSTOPSETC. ANDALLEQUIPMENTREQUIRINGBACKING.

20.WRITTENDIMENSIONSHALLBEUSEDFORLAY-OUT.DONOTSCALE DRAWINGS.

21.THECONTRACTORSHALLVISITTHEJOBSITEANDBERESPONSIBLEFOR THETHEVERIFICATIONOFALLEXISTINGCONDITIONS,ELEVATIONSAND DIMENSIONSPRIORTOCOMMENCINGCONSTRUCTION.

22.THECONTRACTORSHALLBERESPONSIBLEFORLEAVINGALLFINISHED SURFACESCLEANATTHECOMPLETIONOFTHEWORKANDSHALLREMOVEALL EXCESSMATERIALANDDEBRISFROMTHEJOBREGULARLY.

23.ALLCONSTRUCTIONANDWORKMANSHIPSHALLCONFORMTOTHE REQUIREMENTSOFLOCALCODES.

24.RELATIONSHIPOFCONTRACTDOCUMENTS:DRAWINGS,SPECIFICATIONS ANDOTHERCONTRACTDOCUMENTSINTHEPROJECTMANUALAREINTENDED TOBECOMPLIMENTARY.WHATISSHOWNORREQUIREDBYONESHALLBEASIF REQUIREDBYALL.WHATISSHOWNORREQUIRED,ORMAYBEREASONABLY INFERREDTOBEREQUIRED,ORWHICHISUSUALLYANDCUSTOMARILY PROVIDED,SHALLBEINCLUDEDINTHEWORK.

25.THECONTRACTORSHALLCOORDINATETHEINSTALLATIONOFALLITEMS MARKEDO.F.C.I.(OWNERFURNISHED/CONTRACTORINSTALLEDORN.I.C.ITEMS (NOTINCONTRACT)WITHTHEOWNER.

26.THECONTRACTORSHALLBERESPONSIBLEFOROBTAININGTHEFOLLOWING PERMITSINADDITIONTOTHEOTHERPERMITSREQUIRED: A.BUILDINGPERMIT B.STRUCTURALPERMIT C.FIREALARMSYSTEM D.FIRESPRINKLERSYSTEM

EXIST'G.AREA=1,996S.F. TOTALLIVABLEAREA=1,996S.F. TOTALUNDERROOFAREA=LOTCOVERAGE=-%

FAMILY ROOM

LAUNDRY OUTDOOR SHED OUTDOOR SHED KITCHEN

OUTDOOR GARAGE

MASTER BEDROOM CLOS. MASTER BATH DINING

LIVINGROOM

BEDROOM2 BEDROOM1
(CLG.-8'-0")