HV JUICE

HSI
SLEEVES
45° ENTRY
ZERO COMPROMISE
![]()

HSI
45° ENTRY
ZERO COMPROMISE
Inside the sealing system protecting Dunedin's most critical hospital build — one 45° penetration at a time.
Below the basement floor of the new Dunedin Hospital Inpatient Building, Hauff-Technik HSI sleeves and press seals are holding the line against water ingress at every service penetration. Specified by the project architects and supplied by TransNet, the system handles angled duct entries, cast-in wall sleeves, and multi-configuration seals — engineering that has to be right the first time.
Continued on P4



Built specifically for LV reticulation in New Zealand conditions — EP11 solves the problems of older pillar designs and keeps pace with rising electrical and environmental demands.
- contact us for details on recycling
Two-part lid, with front accessed, captive fixing screws — clear separation between Network (mains) and Service connections





Open base with removable kick plate — room to work with larger cables

Tamper-proof, two-piece vents — extra airflow where it's needed, less risk of pillar fires

Interchangeable pre-wired or pre-drilled racks — built-in spacing for heat dissipation, reducing fire risk (customisation available)


Internal, secure fixing screws — protected from corrosion caused by animal urination and outdoor contaminants.


Choose your kitset: two-part lid + panel + interchangeable rack Multiple pre-wired rack options available — talk to us about others.

Following a long process working with the project architects in Christchurch and Dunedin, the design for the new Dunedin Hospital Inpatient Building specified the use of Hauff-Technik penetration sleeves and press seals for all below-ground service penetrations.
The foundation works are well under way. The basement floor design called for raised concrete service plinths to house the various types of ducts entering from underground at 45-degree angles.

Hauff-Technik slanted HSI sleeves were selected by the architect and supplied by TransNet to solve this challenge.
The second-stage top section of the service plinth was then cast around the HSI sleeve assemblies in the required orientations.
The final installation of the Hauff-Technik press seals, to seal around the ducts inside the HSI sleeves, will be completed by the services contractors at the next stage. In addition to the basement floor penetrations, there are also various types of wall penetrations incorporating cast-in wall sleeves and seals in multiple configurations.


HSI150-GSM - Wall insert with Plug-in Socket
✓ Integrated plug-in socket for direct duct connection
✓ No extra connectors required
✓ Pre-mounted with a pressure-tight blind cover for absolute gas and water tightness.
✓ 3-ribbed TPE seal to create a highly reliable, pressure-tight seal against the concrete.
✓ System seal compatibility with standard HSI 150 products.

The special coating creates a strong, waterproof concrete bond
✓ Full-surface seal from cement coating
✓ Easy installation during pour
✓ Compatible with Press Seals
✓ Lightweight and crack resistant
✓ Cost effective reliable seal

✓ Allows an optimal bending radius for feeding and sealing cables or connecting ducts
✓ Injection moulded 3-ribbed TPE seal for gas and water tight seal against the concrete
✓ System seal compatibility with other HSI components
✓ Factory sealed with pressure tight closing cover to prevent unauthorised opening
✓ Cable entry angle options of 30°, 45° or 60° from any direction
The TNJTK1 Jointers Tool Kit brings together 21 essential tools, covering the most commonly used tools for jointers in the field.
Developed in collaboration with experienced cable jointers, this kit ensures you have exactly what you need, no gaps, no guesswork.

TNCIS1552 Insulation stripping tool
TNSCSKIT 3pc semi-con stripper kit
TNCSS Cable sheath stripping tool
TNICT Curved blade chamfer tool
TNCSS25500 15pc insulation stripping kit
TN29700 Black panther snips
*Kit also includes CRC Food Grade Silicon Grease. ^$200 off TNJTK1 kit, valid for August & September 2026 only. Use Code STRIPIT for $200 off^

Housed in a durable carry case with precision foam cut-outs, every tool has its place, making it easy to stay organised and ensuring nothing gets left behind on site. Built for efficiency, reliability, and convenience, the TNJTK1 helps you work faster and with confidence on every job.
removes both inner and outer semi-conductive layers. Cable Range 1552mm OD. 15mm maximum insulation thickness and minimum of 25mm insulation layer length.
for stripping the non-vulcanised semi-conductive layer of MV cables. Maximum cutting depth 2mm. Semi-con pliers included.
for PVC/Rubber insulated cables > 25mm OD, 0 - 5mm Depth. Longitudinal and circumferential circular cuts. Double sided replaceable blade.
curved blade chamfer tool, 16.5mm - 60mm. Tungsten high-speed steel blade. V-shaped jaw automatically centres cable.
25 - 500mm². T-Handle stripping kit, c/w with two T-Handles and 12x interchangeable peeler inserts. Maximum strip length 100mm.
200mm. Stainless steel serrated blades. Spring loaded handles with blade locking tab.

Key Features
✓ Compact & Insulated Design – Made of highly modified, non-flammable silicone rubber that is heavily resistant to tracking
✓ Permanently Bonded Outer Screen – Features a permanently bonded thin-walled conductive screen that protects the system against accidental contact and ensures user safety
✓ Multi-application Use – Can be used on MV networks up to 42kV CAT No. : RSTI-68RC
used in medium voltage (typically 11kV to 33kV) electrical systems to safely cover, seal and earth an unoccupied Type-C equipment bushing
They are primarily used in switchgear, transformers and motors to provide the following functions:
✓ Environmental Protection – Seals the exposed bushing to prevent moisture, dust and debris ingress
✓ Insulation & Safety – Provides a fully insulated, dead-end termination
✓ Grounding – Typically supplied with an integrated earth lead to maintain proper system grounding.
MV Type-C dead-end receptacles (commonly used on 630A or 1250A bushings) require careful testing to ensure the integrity of the insulation, separable connections and the attached power cables. Testing generally includes AC or VLF Withstand, Partial Discharge (PD) Measurement and Tan Delta testing.
✓ Weather & Environmentally Sealed – Designed to prevent moisture ingress and safeguard the exposed, unused connections on dead-break systems
✓ Cable Compatibility – Fully compatible with interface type “C” bushings (630A / 1250A) in accordance with EN 50180/50181
Benefits
✓ Enhanced Safety – The grounded conductive outer screen ensures the touch-safe, “deadfront” integrity of the connection system, preventing accidental shock
✓ Equipment Protection – Protects, insulates and seals the bushings against dust, water and environmental contaminants

✓ Long Service Life – The high performance silicone rubber offers excellent elongation at break, high tracking resistance and unlimited shelf life
✓ Ease of Use – Fits effortlessly onto the rear of the connector to terminate an open circuit, requiring very few accessories for system testing and earthing
✓ Testing - Tested for AC withstand and Partial Discharge prior to leaving the factory
– AC Withstand Voltage: 94kV/1min
– Partial Discharge: 10pC @ 36kV
Remove the Copper, Remove the Risk!
TTEBS – The Innovative Copper Theft Deterrent. Foils potential thieves and protects the network's integrity.
✓ Worthless: Copper-clad steel wire
✓ Tough & Reliable: Hard to cut
✓ Protected: Encased in resin filled conduit
✓ Awkward: Long rigid lengths can't be coiled
✓ Safer: Maintains network integrity, reduces stray voltage risk, and keeps staff safe
Standard and custom lengths available. Contact us to find out more.
Encapsulated cable cross-section within protective PVC pipe



LV fuse carriers have been used for generations and although they work, there has always been room for improvement. IPD has given the status quo a shake up and the TNFC100AFWD/CLR with a clear front cover is what came out!

Features
✓ Self aligning base contacts
✓ Double Terminal Supply & Load Terminals for looping

✓ Dual terminal screws to secure conductor
✓ Compatible with standard TNME22x58 barrel fuses
✓ Clear cover for visual inspection
✓ Made from flame retardant thermoplastic
✓ Standard: Australian Standard AS60269
Double terminals on supply & load
Under and over tightening fuse terminals cause the integrity of the connection to be compromised leading to unnecessary outages for your customers, pillar fires and unplanned maintenance for your fault crews.
Ensure the perfect connection is achieved every time with VDE Torque Screwdriver set.

Precisely adjustable torque with hexagonal shaft for simple pairing with the right blade.
Kit Contents:
+ VDE Torque Settable Handle 1 – 6Nm
+ Setting Key
+ VDE Slotted Blades 2.5, 3.0, 4.0, 5.5 and 6.5mm
+ VDE Phillips Blades 0, 1 and 2
+ VDE Pozi/Slot Combination Blade PZ/Slot 1 and 2
+ Tool Wrap

Features
+ Reduced exposure to live parts
+ Enhanced personnel and public safety
+ Reduction of wildlife-induced faults
+ Mitigation of wildfire ignition risks
+ External CTs can be mounted directly on bushings for compactness – Both line and load sides
+ Allows for direct elbow attachment
+ Good for use with covered conductor
+ Can be fitted with Accusense™ high accuracy, high precision external sensors
Dead-Front design results in a measurable reduction in event frequency and its downstream impact on reliability figures, not just an assumption of improved safety or performance. As utilities continue to strengthen their distribution systems, designs that reduce environmental interaction at the source, without altering protective functions, provide a practical path to improving reliability, safety, and long-term system performance.
Padmount reclosers: Well-suited for renewable interties, urban substations, fenceless substations, and underground feeder protection applications. Additionally, they can function as breakers or tie switches, offering flexibility in system design.
+ Ability to increase phase to phase clearances (Viper®-ST recloser)
+ Screw-on insulators allow for replacement if damaged or for greater creepage distances
+ Up to 170kV BIL and 16kA rms symmetrical (model dependent)
+ Continuous current up to 1000A (Viper®-ST recloser)
+ Multiple mounting options for overhead, underground and sub-station applications
+ Wide temperature range, from –60°C to +65°C
+ Compatible with IEEE 1547 for DER (Distributed Energy Resource) interconnection
+ Full customisation for site-specific designs to support diverse deployment needs
+ Internal CTs are standard
+ Internal Voltage sensors can be 0, 3, or 6, with ratios of 2,500:1 or 10,000:1
+ Site-ready designs are available to speed up installation time
+ Available in L, Z or C configuration
Viper® reclosers utilise epoxy-encapsulated vacuum interrupters, magnetic actuators, and solid dielectric insulation with replaceable polymer insulators for fast, maintenance-free, high-reliability operation.

The Viper®-S recloser is designed with a G&W Electric gang-operated mechanism for three-phase automatic or manual trip operation providing overcurrent protection for systems rated up to 38kV maximum, 1000A continuous, and 12.5kA rms symmetrical interrupting, making it a versatile and exceptionally reliable recloser option for modern distribution networks.


The Viper®-ST recloser combines the time proven reliability of electronically controlled, vacuum fault interrupters with the maintenance-free benefits of a solid dielectric insulated device. The recloser offers ultimate user flexibility by permitting three distinct mechanical operation modes:
– single-phase trip / single-phase lockout
– single-phase trip / three-phase lockout
– three-phase trip / three-phase lockout
A combination of Z-Style and independent phasemodules can provide compact flexible mounting options to overcome pole-top congestion and extra phase clearance requirements, while simplifying installation and improving accessibility. With deadfront and three style options, the Viper®-ST adapts to a wide range of Utility applications.
September 22-24th, 2026

As one of the energy sector’s most anticipated events, EEA 2026 brings together industry leaders, innovators, and forward-thinkers shaping the future of electricity in Aotearoa. And we’re proud to be right in the middle of the action.
Held at the brand new New Zealand International Convention Centre (NZICC) in Auckland city, the conference is shaping up to be a good one! Come and see us in the exhibition hall, stands 96, 97, 98, 99 and our trailer display. This year we will be accompanied by representatives of some of our key supply partners like TE Connectivity , Michaud and G&W Electric co.
This year, we’re showcasing how TransNet is driving smarter, safer, and more resilient networks through collaborative innovation and a focus on practical solutions that deliver real results for our customers and communities.