Master's Portfolio | Sustainable Design

Page 1


PORTFOLIO

MASTER’S IN SUSTAINABLE DESIGN

SELECTED WORKS

2023 - 2025

CONTENTS

Consulting Studio - II

Railway Quarters, Shatabdi Colony, Mysuru

High Performance Building Studio

Academic Block-5, MIT, MAHE, Manipal

Internship Projects

Residential Apartment Project in Bengaluru

Residential Apartment Project in Mumbai

Educational Project in Bengaluru

Residential Villa Project in Hyderabad

Educational Project in Nairobi

III Sem

III Sem

Railway Quarters, Shatabdi Colony, Mysuru | Semester III

In my second year of a master's in Sustainable Design, I had the opportunity to provide sustainability consultation for the Railway Quarters, Shatabdi Colony, Mysuru, a housing project designed by a third-year B.Arch student. The project, located in Vijay Nagar, Gokulam, Mysore, spans a 35,922 sqm site with a built-up area of 53,226 sqm, accommodating 1,300 users across various residential and communal spaces.

The design includes Type II, III, and IV quarters (G+9), a guest house (G+2), and a community hall (G+1), aiming to create a functional and comfortable living environment. My role focused on optimizing energy efficiency, thermal comfort, natural ventilation, and passive design strategies to enhance the project’s sustainability

GUESTHOUSE

COMMUNITY HALL

TYPEII TYPEIV

Climatic analysis; Mysuru

Psychrometric Chart

Windrose diagrams

Focus of the project:

27 3 % - Sun Shading of Windows

36 2 % - Adaptive Comfort Ventilation

For a fully naturally ventilated apartment complex in Mysuru, the winter months provide ideal conditions for natural ventilation However, during summer, additional passive cooling strategies like shading and night-time ventilation are required to reduce the heat gain from solar radiation

Since winds predominantly come from the northeast (Winter) and west/southwest (Summer), orienting the building to take advantage of these directions is beneficial

Ventilation will be more effective in the summer due to higher wind speeds, especially in the afternoons.

TYPEIII

Site level strategies

Maximise air movement

Reduction in sun exposure

Encourage mutual shading

Decrease Solar Heat Gain

Computational Fluid Dynamics - 36% comfort

Site Sun Hours Analysis

Shadow Analysis

Façade Radiation

Computational Fluid Dynamics (CFD) - Summer wind analysis (Western winds)

Site Sun Hours Analysis

Façade Radiation

Shadow Analysis

In the CFD, Options 2 and 4 are the best as they have the most favourable wind distribution, with higher wind velocities across the site, which is beneficial for natural ventilation and cooling Options 2 and 4 receive the least Site Sun Hours, though Option 4 gets the lowest Façade Radiation Option 4 also performs the best in the Shadow Analysis. Option 4 helps reduce solar/façade radiation, increase stable wind flow through the site, and increase natural daylight

EPI = 70 kWh/sqm-year

Absence of shading device at the topmost floor

Oversized shaft size blocking the sunlight

No shading devices on the north and south façades

EPI = 56 kWh/sqm-year

Absence of shading device at the topmost floor

Balcony glass doors are too wide (3 6 m)

No shading on inner surfaces

EPI = 68 kWh/sqm-year

Absence of shading device at the topmost floor

Balcony glass doors are too wide (3 6 m)

No shading on inner surfaces

Proposed case

EPI = 51 kWh/sqm-year

Differential treatment through shading devices

Reduction in shaft size

Addition of windows, ventilators and mesh doors 29% decrease in EPI

EPI = 34 kWh/sqm-year

Differential treatment through shading devices

Reduction in shaft size Addition of windows, ventilators and mesh doors

EPI = 42 kWh/sqm-year

Differential treatment through shading devices

Reduction in shaft size

Equpment(kWh/sqm)

Lighting(kWh/sqm)

Equpment(kWh/sqm)

Lighting(kWh/sqm)

Addition of windows, ventilators and mesh doors. 39% decrease in EPI

Equpment(kWh/sqm)

Lighting(kWh/sqm) Envelope details Envelope details

There was no scope of adding new windows in Type II and Type III to fulfill the cross ventilation credit which is to ensure that minimum 25% of the regularly occupied spaces have an opening to the outdoor, in two orientations

Daylight analysis

33%, 28% and 30% of the total floor area receives illumination between 110-2200 lux on 21st Sept at 12 pm, respectively

Shading device analysis

Extended roof slab acts as shading for balconies and windows

51%, 35% and 44% of the total floor area receives illumination between 110-2200 lux on 21st Sept at 12 pm, respectively

North-West shading blocks significant sunlight in the early afternoon when the sun is at a lower angle, reducing heat gain during critical hours North-East shading effectively blocks sunlight in the morning, when the sun rises in the east and moves toward the south South-East shading efficiently shields against sunlight during the morning, as the sun rises in the east and shifts toward the south South-West shading blocks afternoon and late afternoon sunlight, which reduces solar heat gain

RETV

The base case shows RETV values of 11 9, 12 0, and 11 2 W/sqm for Type II, Type III, and Type IV, respectively While these values are below the Eco Niwas Samhita limit, they indicate potential heat gain that could impact indoor thermal comfort

The proposed design significantly improves energy performance, reducing RETV values to 7.6, 4.2, and 3.9 W/sqm, enhancing thermal comfort and reducing cooling loads Additionally, the roof U-value is optimized to 2 67 W/m²K, contributing to better insulation and reduced heat transfer

Base case

Internal CFD analysis

Due to the absence of openings in the kitchen and living room, there is no movement of air observed

The effect of the presence of openings is observed in the corner apartments in the kitchen and living rooms

There is a potential of taking in air from the lobby area due to the opening on the front façade.

Thermal comfort analysis

Proposed case

A mesh door has been added in the living room to cause air movement in the space

A ventilator has been added in the kitchen opening to the lobby area to cause air movement in the space

Ventilators were added on top of bedroom doors to facilitate air movement throughout living the room.

We can see the comfort hours of the proposed case increase compared to the base case in each type It is due to the application of strategies like reduction in appropriate shading devices, provision of additional windows, and envelope optimisation

On-site renewable energy potential

South-facing

South-facing modules angled at 27°

generated = 83,737 kWh 21% of electricity by solar PV

reduced: 35 to 27.6 kWh/sqm-yr

South-facing modules angled at 27°

PV generated = 35,233 kWh

17% of electricity by solar PV

reduced: 42 to 34 58 kWh/sqm-yr

Academic Block - 5, MIT, MAHE, Manipal | Semester III

During my third semester, I worked on a project aimed at improving the sustainability performance of Academic Block 5, MIT, Manipal an eight-floor, fully air-conditioned engineering college building on the MAHE campus through experiments and simulations.

The study focused on two key spaces:

Daylight Analysis: Conducted in SOIS’s lab (located on the fifth floor), using a daylight sensor/lux meter to measure illuminance levels

Thermal Comfort Analysis: Assessed in Classroom 506 (fifth floor) using Testo instruments including a globe thermometer, tubulometer, and CO₂ sensor to evaluate PMV (Predicted Mean Vote), PPD (Predicted Percentage of Dissatisfied), relative humidity (RH), and CO₂ concentration

My primary responsibility was to analyze the collected data and propose strategies to enhance the building’s sustainable performance. I developed passive and active design interventions by interpreting real-time measurements and simulation results to optimise indoor environmental quality, daylighting efficiency, and energy consumption while maintaining occupant comfort.

Experiments

LGF: -2

Daylight Analysis

In Case 1 and Case 3, the lux levels were very low, which indicates that daylight is not sufficient for proper illumination in these areas. With artificial lights on (Cases 2 and 4), the lux levels are much higher, showing that the classroom heavily relies on artificial lighting This increases energy consumption and suggests the need for better daylight optimisation strategies, such as reflective surfaces or light shelves.

UGF: +5

Thermal Comfort Analysis

PMV:-0.1,PPD:5.2%

The overall average CO₂ concentration is found to be 2,935 ppm, which is a high concentration of CO₂ levels ASHRAE recommends that indoor CO2 levels should not exceed 1000 ppm in occupied spaces. This can indicate insufficient fresh air intake in the HVAC system

Maximize Daylight and Minimize Glare

Utilize Lightweight Construction

Envelope Optimisation

Decrease Cooling Load while increase Thermal Comfort

A parametric analysis for solar radiation was done from an angle of 1° to 360° to find the ideal orientation to reduce the solar heat gain of the building 255° has the most optimised angle with the lowest solar radiation.

*‘E+07’ signifies ten to the power 7

Daylight Analysis

Only 9%, 12%, 8% of the total floor area receives illumination between 110-2200 lux on 21st Sept at 12 pm, respectively

Only 25%, 35%, 28% of the total floor area receives illumination between 110-2200 lux on 21st Sept at 12 pm, respectively Base case

Solar Ingress Analysis

Thermal comfort analysis

PMV ranges from 0 92 to 0 93 suggesting that occupants would feel slightly warm PPD ranges from 22 77% to 23 42% This means about 23% of the people in the space are expected to feel uncomfortable

PMV ranges from 0 71 to 0 75; these values indicate that the occupants are not experiencing significant discomfort PPD ranges from 15% and 18%, around 80% or more are likely to feel comfortable

Residential Apartment Project in Bengaluru

Facade Radiation

Option 1

Option 1 has annual façade radiation value of 4 22 x 10^7 kWh/ sqm

Site Sun Hours Analysis

Option 1 has an average of 1702 hours of sun exposure

Facade Radiation

Option 2

Option 2 has annual façade radiation value of 4 27 x 10^7 kWh/ sqm

Site Sun Hours Analysis

Option 2 has an average of 1589 hours of sun exposure

Observations: Option 1 minimizes overall façade radiation due to mutual shading of east and west facades but leads to higher heat gain, glare issues, and increased site sun hour exposure Option 2 has a lower average site sun hour exposure but more exposure to the east and west compared to Option 1

Residential Apartment Project in Mumbai

Daylight Analysis

Daylight analysis has been performed on Design Builder Building has been modeled in Design Builder based on architectural drawings from design team Daylight Illuminance analysis has been performed at sun sky 21st September at 12:00 Outside lux has been taken from EPW weather file of Mumbai

Observations:

Base Case illuminance values help achieve 1 point for IGBC Enhanced Daylight Criteria requirement The illuminance levels > 110 lux has improved in proposed case compared to base case

Glare levels has increased due to increase in VLT

Base Case

Observations:

RETV Analysis

The proposed case has a significantly lower roof U-value (0 38 W/m²K) compared to the existing buildings, indicating improved insulation.

RETV values in the proposed case (9 2, 10 2, and 10 3 W/sqm) are lower than in the existing towers, suggesting reduced heat gain

The material selection in the proposed case enhances thermal performance by reducing overall U-values.

Tower 6 consistently shows the highest RETV, indicating it experiences more heat gain than Towers 2 and 4

The proposed improvements suggest better thermal comfort and energy efficiency, reducing cooling loads

Educational Project in Bengaluru

Below parameters were considered for thermal comfort analysis:

1 Rammed Earth Wall + Concrete Block + Plaster vs Rammed Earth Wall

2 Clay Tile Roofing vs Clay Tile Roofing + PUF Insulation

3 Single Glazing - 80%VLT, 0 8 SHGC, 5 6 U-value vs Single Glazing - 65%VLT, 0 65 SHGC, 5 6 U-value

4 Window Open – 50% vs 100%

5.LED Lights

6. Occupancy (160 for Auditorium, 40 for Workshop)

Adaptive Thermal Comfort

As per the adaptive comfort method, the operative temperature of 29⁰C inside the space is comfortable at outdoor mean temperature of 26.6⁰C and Indoor air speed of 0.6m/s with ceiling fan ON

Base Case

Proposed Case

Residential Villa Project in Hyderabad Wind Analysis

Predominant wind directions observed are: Eastern winds during the winter months between October to March with wind speeds averaging at 3 m/s. Summer faces winds at 4 m/s from the West between April to June.

Observation:

The linearly aligned plots and buildings which are along the wind path, are blocking the wind This results in wind shadow areas where stagnation of wind is observed

It is proposed to stagger the plots and villas along the vertical axis to allow for clear wind flow across the plots

Educational Project in Nairobi

Wind Analysis

Predominant wind directions from wind rose diagram is observed to be the Northeast direction.

5 m/s max Wind speed is notified from the plot

Observation:

Wind stagnation is observed in the common areas and building periphery

Tilting the building towards the right so that it is oriented north east to south west direction will solve the wind stagnation issue Dec