2' - 1"
F
INTERIOR WALL ASSEMBLY PARTITION TYPE: CC40 - 7 5/8'' MASONRY CONCRETE UNIT - 3 5/8'' METAL STUD - 5/8'' TYPE ''X'' GYPSUM BOARD
INTERIOR SHAFT WALL ASSEMBLY UL #U415 B PARTITION TYPE: J41 - (3) 5/8" TYPE "X" GYPSUM BOARD - 1-1/2" METAL STUD - 1" GYPSUM BOARD SHAFT WALL LINER 16
(2) 2-1/2" METAL STUDS @ CORNER FIRE-RATED COLUMN ASSEMBLY UL #X513 PARTITION TYPE: DD31 - (2) 5/8" TYPE "X" GYPSUM BOARD - 2-1/2" METAL STUD
3'-8 7/16"
1'-7 1/2" 9 3/4"
STEEL COLUMN, SEE STRUCTURAL
FIREPROOFING FIRE-RATED COLUMN ASSEMBLY UL#X525
C C
INTERIOR WALL ASSEMBLY PARTITION TYPE: D31 - 5/8'' GYPSUM BOARD - 2-1/2'' METAL STUD
10 1/16"
E
(2) 2-1/2'' METAL STUDS AT CORNER
9 5/8"
FIREPROOFING
10 7/8"
STEEL COLUMN, SEE STRUCTURAL
INTERIOR WALL ASSEMBLY: 2-HR RATED UL #U419 PARTITION TYPE: BB50 - (3) 5/8" TYPE "X" GYPSUM BOARD - 6" METAL STUD - ACOUSTICAL INSULATION, AS SCHEDULED - 5/8" TYPE "X" GYPSUM BOARD
ALIGN
ALIGN
7 7/8" 1'-5 5/8"
5
9 A604
11
COLUMN WALL DETAIL 1 1/2" = 1'-0"
9
13 COLUMN ENCLOSURE AT CORRIDOR SHAFT 1ST FLOOR 1 1/2" = 1'-0"
10 A604
COLUMN ENCLOSURE AT SHAFT 2ND-5TH FLOOR 1 1/2" = 1'-0"
INTERIO PARTITI - 5/8" GY - 3 5/8" M - 5/8" GY
H.M. DOOR FRAME - GROUTED SOLID
(2) 2-1/2" METAL STUD @ CORNER STEEL COLUMN, SEE STRUCTURAL
9 3/4"
FIRE-RATED COLUMN ASSEMBLY UL #X513 PARTITION TYPE: DD31 - (2) 5/8" TYPE "X" GYPSUM BOARD - 2-1/2" METAL STUD
10 1/8"
FIELD CUT CMU AS NEEDED
INTERIOR WALL ASSEMBLY PARTITION TYPE: D31 - 5/8" GYPSUM BOARD - 3 5/8" METAL STUD - 5/8" GYPSUM BOARD
FIREPROOFING
(2) 3 5/8"
EXTERIOR WALL ASSEMBLY: 2 HR RATED UL 902
D
INTERIOR WALL ASSEMBLY: 1-HR RATED UL #U419 PARTITION TYPE: BB50 - (2) 5/8" TYPE "X" GYPSUM BOARD - 6" METAL STUD - ACOUSTICAL INSULATION, AS SCHEDULED - 5/8" TYPE "X" GYPSUM BOARD
9 8 A604
INTERIOR WALL ASSEMBLY: 2-HR RATED UL #U905 PARTITION TYPE: CC40 - 7 5/8" CONCRETE MASONRY UNIT - 3 5/8" METAL STUD - 5/8" TYPE "X" GYPSUM BOARD
ALIGN
COLUMN ENCLOSURE AT CORRIDOR 2ND-5TH FLOOR 1 1/2" = 1'-0"
14
4 7 A604
INTERIO PARTITI - 7 5/8" C
- BRICK - 1" MIN AIR SPACE (VARIES, SEE A-203 & 204 FOR DETAILS) - 1 5/8" CLOSED CELL RIGID INSULATION SYSTEM WITH INTEGRATED AIR AND WATER BARRIER - CONTINUOUS VAPOR-PERMEABLE, LIQUID APPLIED AIR AND WATER BARRIER - 7 5/8" CMU. SEE STRUCUTRAL DRAWINGS FOR DETAILS.
(2) 3-5/8" METAL STUDS AT CORNER
ALIGN
INTERIO PARTITI - 3 5/8" M - 5/8" GY
ALIGN
1'-7 1/2" 9 3/4"
ALIGN
D
5
PLAN DETAIL- CMU WALL AT PUMP ROOM 1 1/2" = 1'-0"
A604
PLAN DETAIL- CMU WALL AT PACKAGE ROOM 1 1/2" = 1'-0"
C
6 A604
PLAN DETAIL- CMU WALL AT WEST STAIR 2 1 1/2" = 1'-0"
INTERIOR WALL ASSEMBLY PARTITION TYPE: CC30 - 7 /8" CONCRETE MASONRY UNIT - 7/8" METAL HAT-SHAPED CHANNEL - 5/8" TYPE "X" GYPSUM BOARD
FIREPROO
INTERIOR PARTITION - 2 1/2" ME - 5/8" GYPS
CMU GROUTED SOLID @ WALL INTERSECTION, TYP.
INTERIOR WALL ASSEMBLY PARTITION TYPE: D51 - 3 5/8" METAL STUD - 5/8" GYPSUM BOARD
1'-5 3/8"
STEEL CO
10"
INTERIOR WALL ASSEMBLY PARTITION TYPE: D51 - 3 5/8" METAL STUD - 5/8" GYPSUM BOARD
CMU GROUTED SOLID @ WALL INTERSECTION
B
1'-11 5/8"
B
EXTERIOR
BASSEMBLY: 2-HR RATED UL #U905 INTERIOR WALL PARTITION TYPE: Z30 - 7 5/8" CONCRETE MASONRY UNIT
- BRICK - 1" MIN AI - BRICK TI - 2" CLOS - (1)- EXTE - CONTINU AIR AND - 6" METAL AND STR - 5 1/2" BA (R-20, TO - (1)- LAYE
ALIGN
1'-11 5/8"
INTERIOR WALL ASSEMBLY PARTITION TYPE: D31 - 2 1/2" METAL STUD - 5/8" GYPSUM BOARD
INTERIOR WALL ASSEMBLY: 2-HR RATED UL #U905 PARTITION TYPE: CC40 - 7 5/8" CONCRETE MASONRY UNIT - 3 5/8" METAL STUD - 5/8" TYPE "X" GYPSUM BOARD
13 4 A604
EAST ENCLOSURE AT ELEVATOR RECESS 1 1/2" = 1'-0"
INTERIOR PARTITION - 5/8" GYP - 6" METAL - ACOUST - 5/8" GYPS
INTERIOR WALL ASSEMBLY: 2-HR RATED UL #U905 PARTITION TYPE: CC40 - 7 5/8" CONCRETE MASONRY UNIT - 3 5/8" METAL STUD - 5/8" TYPE "X" GYPSUM BOARD
12 3 A604
WEST ENCLOSURE AT ELEVATOR RECESS 1 1/2" = 1'-0"
12
14 2 A604
PLAN DETAIL- STOREFRONT WALL CURVE 1 1/2" = 1'-0"
1 A604
COLUMN ENCLOSURE AT EXTERIOR WALL 1 1/2" = 1'-0"
A
7
0'-0"
0'-6 0'-3"