ANSWERS TO Commercial Refrigeration QUIZ

Chapter 6 – Controls & Accessories

Name:_ MASTER ___________ Number Right:___________ Scored by:____________ a. 2° b. 5° c. 10° d. 20° a. It has a narrow temperature swing. b. The tstat won’t start the compressor until the evaporator frost has melted. c. The tstat knows when to go into defrost. a. Maintains a minimum suction pressure at the compressor b. Keeps pressures and temperatures up in the evaporator. c. Prevents compressor overload during hot pull-down. a. Maintains a minimum suction pressure at the compressor b. Keeps pressures and temperatures up in the evaporator. c. Prevents compressor overload during hot pull-down a. Store refrigerant on TEV systems and systems with HPR valves. b. Prevents compressor from floodback during hot pull-downs. c. Keeps head pressure up during low ambient conditions. a. Store refrigerant on TEV systems and systems with HPR valves. b. Protects the compressor from floodback during hot pull-downs. c. Keeps head pressure up during low ambient conditions. a. 1° b. 3° c. 5° d. 10° a. Keeps heat in the liquid line during low ambient conditions. b. Prevents floodback by boiling off liquid refrigerant in the suction line. c. Subcools the liquid refrigerant to prevent flash gas before the TEV. a. Crankcase pressure and oil pump discharge pressure. b. Suction pressure and head pressure. c. Low side pressure and receiver pressure. a. 10 seconds b. 30 seconds c. 60 seconds d. 120 seconds

1. What is the temperature swing of an air sensing commercial refrigeration thermostat?

2. How does a coil sensing tstat prevent frost on a medium temperature evaporator?

3. What is the primary function of a CPR valve?

4. What is the primary function of an EPR valve?

5. What is the primary function of a receiver?

6. What is the primary function of an accumulator?

7. What is the maximum temperature drop across a liquid-line filter drier?

8. What is the primary function of a heat exchanger in a refrigeration system?

9. What two pressures does an oil safety control monitor?

10.What is the normal time delay in an oil safety control before it trips?