1250 Lever Operated Valve Application The WellMark lever operated “dump” valve is used in conjunction with a float nose to dump oil or water from separators, knockouts, treaters, and other accumulators.

Features • 500 psi Working Pressure, Std. • Ductile Iron Body and Bonnet • Balanced Double Seats for High Flow • No Diaphragms to Rupture

Specifications

Dimensional Data

Working Pressure . . . . . . . . . . . . . . . . . . . . . . . . . . 500 psi 15"

Material Body 2" Globe or Angle . . . . . . . . . . . . . . . . . . Ductile Iron

6 7/8

Bonnet . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Ductile Iron Trim . . . . . . . . . . . . . . . . Viton® Molded Plug, Integral Seat Stem . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 303 S.S. 2" NPT

Stuffing Box . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Steel

4"

Installation WellMark Float Nose

4"

2" NPT Angle Valve 15"

6 7/8

WellMark Lever Operated Oil Valve

3 7/16

2" NPT

7 3/4

2" NPT Globe Valve

The

Company, L.L.C. • Oklahoma City, Oklahoma • Tel: (405) 672-6660 • Fax: (405) 672-6661 • wellmarkco.com

©2003 The WellMark Company • Litho USA • WM1250-10/03 • All registered trademarks are the property of their respective owners.