NATURAL LIGHT Analysis

From the simulations it can be seen that there are areas of the Ground Floor that are particularly dark due to the fact that this level is partially underground. For most of the usefull area, the DF is between 2 and 6%, which is the optimal range for not having too much or too little light. In the First Floor the natural light quantity inside the building is greater, thanks to the greater number of windows that are present. Despite this, the values in most of the area are less than 6 percent and therefore good. There are restricted areas at the larger openings where the light could be annoying and create glare. At the Top Floor light is nevertheless present in acceptable values, thanks to the system of shading elements on the outside of the façade. There are also some areas with a DF greater than 6% and therefore at risk of glare.