5. Understanding the Premium and Classic Overlays

5. UNDERSTANDING THE PREMIUM AND CLASSIC ALLOTMENT OVERLAYS

General Description This overlay determines the standard of key elements of the house. These elements need only be provided in the controlled zones of the house, as follows:

Advertisement

Overlay C: Classic Allotments

Additional Control Category Additional Control

Roof Pitch Minimum 22.5 degrees Excludes verandahs, which must be pitched, but may be constructed at a shallower angle to suit headroom requirements at the outer edges. Eaves Overhang Not less than 450mm Ceiling Heights Minimum 2400mm Ceilings to ground floor only Verandahs Verandahs and Porticos are to be provided to not less than 25% of width of the dwelling facing the street, with a depth of not less than 1.8 metres.

On lots less than 10 metres in width, verandahs are to be provided to not less than 40% of width of the dwelling facing the street, with a depth of not less than 1.8 metres.

Overlay P: Premium Allotments

Additional Control Category Additional Control

Roof Pitch Minimum 27 degrees Excludes verandahs, which must be pitched, but may be constructed at a shallower angle to suit headroom requirements at the outer edges. Eaves Overhang Not less than 600mm Ceiling Heights Minimum 2700mm Ceilings to ground floor only Verandahs Verandahs and Porticos are to be provided to not less than 40% of width of the dwelling facing the street, with a depth of not less than 1.8 metres.