Work sample

Page 1


INTENT OF THE PLANS OR SPECIFICATIONS IS NOT CLEAR, THE CONTRACTOR SHALL REQUEST CLARIFICATION FROM THE ARCHITECT BEFORE PROCEEDING WITH THE WORK.

4. DIMENSIONS ON PLANS ARE TO FACE OF STRUCTURE. UNLESS OTHERWISE NOTED. FINISH MATERIALS

5. VISIT TO THE SITE: THE CONTRACTOR SHALL VISIT THE SITE PRIOR TO SUBMITTING HIS PROPOSAL FOR THE WORK AND SHALL NOT START WORK UNTIL HE IS SATISFIED THAT THE ACTUAL CONDITIONS ARE SUBSTANTIALLY AS SET FORTH IN THE DRAWINGS. ONCE HAVING STARTED WORK, HE SHALL BE DEEMED TO HAVE ACCEPTED THE EXISTING CONDITIONS AS READY FOR HIS WORK, AND IT WILL BE HIS RESPONSIBILITY TO MAKE WHATEVER ADJUSTMENTS, CORRECTIONS AND REPAIRS TO THEM AS REQUIRED TO MAKE THE PROJECT COMPLETE WITHOUT EXTRA COMPENSATION.

6. THE GENERAL CONTRACTOR SHALL MAINTAIN THE JOB SITE IN A CLEAN, ORDERLY CONDITION, FREE OF DEBRIS AND LITTER. EACH SUBCONTRACTOR IMMEDIATELY UPON COMPLETION OF EACH PHASE OF HIS WORK SHALL REMOVE ALL TRASH AND DEBRIS AS A RESULT OF HIS OPERATION. IN ADDITION, THE GENERAL CONTRACTOR, ATTHE COMPLETION OF THE JOB, SHALL HAVE ALL AREAS INVOLVED IN THE WORK THOROUGHLY CLEANED. WASH ALL WINDOWS, REMOVING ALL FOREIGN MATTER FROM THE FRAMES AND GLASS. CLEAN ALL FINISHED FLOORS AND SWEEP ALL UNFINISHED FLOORS, WASH ALL FIXTURES AND TILED SURFACES, AND REMOVE ANY SPILLS OR SPLATTERS FROM FINISH SURFACES. CLEAN ALL EXTERIORSIDEWALKS, SLABS AND DECKS.

7. THE CONTRACTOR SHALL CONFINE OPERATIONS TO THE SITE AREAS PERMITTED BY LAW, ORDINANCES, PERMITS, AND THE CONTRACT DOCUMENTS AND SHALL NOT UNREASONABLY ENCUMBER THE SITE WITH ANY MATERIALS AND EQUIPMENT.

8. ALL WORK UNDER THIS CONTRACT SHALL BE IN STRICT ACCORDANCE WITH THE LATEST ADOPTED EDITION CALIFORNIA BUILDING CODE (2022 CBC), CALIFORNIA RESIDENTIAL CODE (2022 CRC), CALIFORNIA PLUMBING CODE (2022 CPC), CALIFORNIA MECHANICAL CODE (2022 CMC), CALIFORNIA ELECTRICAL CODE (2022 CEC), WITH LOCAL LAWS AND REGULATIONS. IN THE EVENT THAT A CONFLICT OCCURS BETWEEN THE DRAWINGS AND SPECIFICATIONS AND THESE REQUIREMENTS, THE MORE STRINGENT REQUIREMENT SHALL GOVERN.

9. SITE DRAINAGE: PROVIDE GUTTERS AND RAIN WATER LEADERS FOR ROOF DRAINAGE. DIRECT RAIN WATER LEADERS AWAY FROM BUILDING WITH SPLASHBLOCKS. THE SITE SHALL BE FINE GRADED TO PROVIDE 2% (@HARDSCAPE SURFACES) OR 5% (@LANDSCAPE SURFACES) MINIMUM SLOPE AWAY FROM THE PERIMETER OF THE RESIDENCEAND GARAGE FOR A DISTANCE OF 8 FEET, WHERE POSSIBLE. IN NO CASE SHALL THE FINISH GRADING RESULT IN AN INCREASE IN SHEET FLOW ONTO ADJACENT PROPERTIES.

10. GENERAL CONDITIONS: THE LATEST EDITION OF THE AMERICAN INSTITUTEOF ARCHITECTS GENERAL CONDITIONS

POLLARD REMODEL MAIN HOUSE

SCOPE OF WORK

ABBREVIATIONS

PROJECT DATA

CONTACTS

OWNER: SCG LEGACY LLC

(408) 831-1078

EMAIL: PROJECTS@ALPHAINBAY.COM

DESIGNER:

TEL: (408) 579-9738

EMAIL: PERMIT@TDDGUS.COM

SURVEYOR:

TEL: 888.310.0808

1 RANGE, ELECTRIC LOCAL EXHAUST VENTILATION HOOD, MIN. 100 CFM ISLAND VENTING, SEE DETAIL 1 SHEET AD.3 WATER HEATER, HEAT PUMP

FURNACE, GAS IN THE ATTIC ACCESS 2

3 4 5 (N)ELECTRIC

WALL LEGEND

(N)2x6 STUDS (EXTERIOR)

(N)2X4 STUDS (INTERIOR)

(N)2X4 STUDS, 1-HOUR FIRE RATED, SEE WALL SCHEDULE NOTE 1

(N)2X6 STUDS, GRAB BAR REINFORCEMENT, SEE DETAIL 4 SHEET AD.3

(E)2x4 STUDS (INTERIOR)

(E)2X6 STUDS (EXTERIOR)

(E)2X6 STUDS (EXTERIOR) 1-HOUR FIRE RATED, SEE WALL SCHEDULE NOTE 1

WALL SCHEDULE NOTES

1 PROVIDE 5/8" (1/2" MIN.) TYPE X GYP. BD. @ GARAGE SIDE OF COMMON WALLS, CEILING & SUPPORTING MEMBERS (EG. BEAMS, COLUMNS & BEARING WALLS) FOR OCCUPANCY SEPARATION FROM FOUNDATION TO ROOF SHEATHING. CRC TABLE R302.6. DUCTS IN THE GARAGE OR PENETRATING THE WALLS OR CEILINGS SEPARATING THE DWELLING FROM THE GARAGE SHALL BE CONSTRUCTED OF A MINIMUM 26 GAGE SHEET STEEL OR OTHER APPROVED MATERIAL AND SHALL HAVE NO OPENINGS INTO THE GARAGE -PER CRC R302.5.2.

DOOR SCHEDULE

MarkDESCRIPTIONWIDTHHEIGHTTEMPERED

ADoor-Single-Flush13' - 0"6' - 8"No

BDoor-Single-Flush2' - 6"6' - 8"No

CSingle-Flush2' - 6"6' - 8"No

DSingle-Flush2' - 6"6' - 8"No

EDoor-Single-Flush2' - 6"6' - 8"No

FSingle-Flush2' - 6"6' - 8"No

GDoor-Interior-Double-Sliding-2_Panel-Wood6' - 0"6' - 8"No

HDoor-Interior-Double-Sliding-2_Panel-Wood6' - 0"6' - 8"No

IDoor-Single-Flush2' - 0"8' - 0"No

WINDOW SCHEDULE

MarkDESCRIPTIONWIDTHHEIGHT SILL HEIGHT EGRESSTEMPERED

PLATFORM ON WORKING SIDE OF UNIT, MINIMUM 30" HEADROOM ABOVE PLATFORMS, RECEPTACLE AT UNIT FOR MAINTENANCE, LIGHT AT UNIT SWITCHED AT ACCESS, GAS SUPPLY AND NECESSARY COMBUSTION AIR. REQUIREMENTS SIMILAR FOR CRAWL SPACE FURNACE (INSTALL ON CONCRETE SLAB NOT LESS THAN 3" ABOVE ADJOINING GROUND LEVEL) CMC SECTION 904.3.1.1.

16. TEMPERED (SAFETY) GLAZING IS REQUIRED IF THE WINDOW IN QUESTION MEETCOS ALL OF THE FOLLOWING CONDITIONS (PER CEC R308.4.3): A.THE EXPOSED AREA OF AN INDIVIDUAL

THE GLAZING IS MORE THAN 36 INCHES (914 MM) ABOVE THE FLOOR.

D.ONE OR MORE WALKING SURFACES ARE WITHIN 36 INCHES (914 MM), MEASURED HORIZONTALLY AND IN A STRAIGHT LINE, OF THE GLAZING. FOR WET SURFACES AT BATHTUBS, SHOWERS, POOLS ETC.: E.THE BOTTOM EXPOSED EDGE OF THE GLAZING MUST INSTEAD BE 60 INCHES (1524 MM) ABOVE STANDING OR WALKING SURFACES. UNLESS THE GLAZINGIS MORE 60 INCHES (1524 MM) MEASURED HORIZONTALLY AND IN A STRAIGHT LINE FROM WATER'S EDGE. (PER. CEC R308.4.5) FOR WINDOWS ADJACENT TO DOORS: F.WINDOWS WITHIN 24" OF DOORS MUST BE TEMPERED. UNLESS THE GLAZING IS MORE 60 INCHES (1524 MM) MEASURED VERTICALLY AND IN A STRAIGHT LINE FROM ABOVE THE FLOOR. 17. RISERS ON STAIRWAYS SHALL NOT BE LESS THAT 4", NOR GREATER THAN 7-3/4". THE GREATEST RISER HEIGHT SHALL NOT EXCEED THE SMALLEST BY MORE THAN 3/8". THE

1Window-SlidingDouble <varies><varies>4' - 2"YesNo

2Window-SlidingDouble 6' - 8"2' - 6"4' - 2"NoYes

3Window-SlidingDouble 6' - 8"2' - 6"4' - 2"NoNo

4Window-SlidingDouble 6' - 0"4' - 0"2' - 8"NoNo

5Window-SlidingDouble 6' - 0"4' - 0"2' - 8"NoNo

6Window-SlidingDouble 6' - 0"4' - 0"2' - 8"NoNo

7Window-SlidingDouble 6' - 0"4' - 0"2' - 8"NoYes

8Window-SlidingDouble 6' - 0"4' - 0"2' - 8"YesNo

9Window-SlidingDouble 3' - 0"4' - 0"<varies>NoYes 6' - 8" 2' - 6"

RIGHT ELEVATION

ELEVATION NOTES

ATTIC VENTILATION CALCULATIONS

CRAWL SPACE VENTILATION CALCULATIONS

NOTES

FLOOR PLAN NOTES

- 6"6' - 8"

Panel Door3' - 0"6' -

- 6"6' - 8" JSINGLE

- 8"

DOOR2' - 6"6' - 8" LSINGLE FLUSH DOOR2' - 0"6' - 8" MSINGLE FLUSH DOOR2' - 0"6' - 8"

N2 Panel Door2' - 8"6' - 8"

O2 Panel Door2' - 8"6' - 8"

PSLIDING CLOSET DOOR5' - 0"6' - 8"

QSLIDING CLOSET DOOR5' - 0"6' - 8"

RSLIDING CLOSET DOOR5' - 0"6' - 8"

WINDOW SCHEDULE

MarkDESCRIPTIONWIDTHHEIGHT SILL HEIGHT EGRESSTEMPERED

1aWindow-Casem ent-Double 6' - 0"4' - 0"2' - 8"YesNo

1bWindow-Casem ent-Double 6' - 0"4' - 0"2' - 8"NoNo

1cWindow-Casem ent-Double-with -Fixed

1dWindow-Casem ent-Double-with -Fixed

8' - 0"4' - 8"2' - 0"YesNo

8' - 0"4' - 8"2' - 0"YesNo

1eFixed1' - 8"6' - 8"0' - 0"NoYes

1fWindow-Casem ent-Double-with -Fixed

1gWindow-Casem ent-Double

1hWindow-Casem ent-Double

8' - 0"4' - 8"2' - 0"NoYes

3' - 0"4' - 0"2' - 8"NoNo

6' - 0"4' - 0"2' - 8"YesNo

1iFixed1' - 8"6' - 8"0' - 0"NoYes

1jFixed1' - 8"6' - 8"0' - 0"NoYes

1kWindow-SlidingDouble 6' - 0"4' - 0"2' - 8"No

1lWindow-Casem ent-Double 3' - 0"4' - 0"2' - 8"NoYes

1mWindow-Casem ent-Double

3' - 0"4' - 0"2' - 8"NoNo

1nWindow-Casem ent-Double 6' - 0"4' - 0"2' - 8"YesNo

1oWindow-SlidingDouble

3' - 0"2' - 0"4' - 8"NoYes

SURFACES ARE WITHIN 36 INCHES (914 MM), MEASURED HORIZONTALLY AND IN A STRAIGHT LINE, OF THE GLAZING. FOR WET SURFACES AT BATHTUBS, SHOWERS, POOLS ETC.:

E.THE BOTTOM EXPOSED EDGE OF THE GLAZING MUST INSTEAD BE 60 INCHES (1524 MM) ABOVE STANDING OR WALKING SURFACES. UNLESS THE GLAZINGIS MORE 60 INCHES (1524 MM)MEASURED HORIZONTALLY AND IN A STRAIGHT LINE FROM WATER'S EDGE. (PER. CEC R308.4.5) FOR WINDOWS ADJACENT TO DOORS: F.WINDOWS WITHIN 24" OF DOORS MUST BE TEMPERED UNLESS THE GLAZING IS MORE 60 INCHES (1524 MM) MEASURED VERTICALLY AND IN A STRAIGHT LINE FROM ABOVE THE FLOOR.

17. RISERS ON STAIRWAYS SHALL NOT BE LESS THAT 4", NOR GREATER THAN 7-3/4". THE GREATEST RISER HEIGHT SHALL NOT EXCEED THE SMALLEST BY MORE THAN 3/8". THE RUN SHALL NOT BE LESS THAN 10", NOSING TO NOSING. THE LARGEST RUN SHALL NOT EXCEED THE SMALLEST BY MORE THAN 3/8"

18. GUARDRAILS SHALL BE 42" MINIMUM HIGH, WITH INTERMEDIATE RAILS SPACED A MAXIMUM OF 4", AND SHALL HAVE MATERIALS AND FASTENERS CAPABLE OF WITHSTANDING ASINGLE CONCENTRATED 200 LBS. LOAD APPLIED IN ANY DIRECTION AT ANY POINTALONG THE TOP OF THE RAIL PER CRC TABLE R3015 & R301.5 ITEM D.

19. HANDRAILS SHALL BE BETWEEN 34"-38" ABOVE TREAD NOSING, AND BE 1-1/4" TO 2" IN CROSS SECTION EXTEND FROM TOP TO BOTTOM RISER AND TERMINATE AT NEWELPOTS OR RETURN TO WALL.

20. SLOPE OF ALL EXTERIOR LANDINGS SHALL NOT EXCEED 2% SLOPE

21.ALL DIMENSIONS AT WINDOWS & DOORS ARE THE CENTERLINE (U.O.N)

22. BATH: A.30" WIDE CLEAR SPACE (15" MIN. FROM WALL OR OBSTRUCTION TO CENTER OF W/C),

4.

5.

6.

7.

8.

ELECTRICAL SYMBOLS

ELECTRICAL NOTES

101RECEPTION748 SFN/A 102MEETING ROOM155 SFGYP. 103BUSINESS MGR.107 SFGYP. 104OFFICE 1112 SFGYP. 105OFFICE 2113 SFGYP. 106TREATMENT125 SFGYP. 107TREATMENT124 SFGYP. 108TREATMENT126 SFGYP. 109TREATMENT126 SFGYP. 110TREATMENT125 SFGYP. 111XRAY AND COMPUTERS 79 SFGYP. 112STERILIZATION236 SFN/A 113RESTROOM50 SFGYP. 114RESTROOM50 SFGYP. 115EQUIPMENT29 SFGYP. 116STORAGE47 SFGYP. 117TEAM ROOM178 SFGYP. 118SERVER16 SFGYP. 301HALLWAY330 SFN/A

3/4"HMHMHMN/A

3/4"HMHMHMN/A

0"7' 0"0' 3/4"HMHMHMN/A

0"7' 0"0' 3/4"HMHMHMN/A

0"7' 0"0' 3/4"HMHMHMN/A

0"7' 0"0' 3/4"HMHMHMN/A

DOOR LEGEND

3/4"HMHMHMN/A

DOOR SCHEDULE

PF-03TOTOTEL133

PF-06GUARDIANG1849EYEWASHERDECK

PF-07ELKAYEFRU191610TSINGLE

PF-08

PF-09ELKAYFLR-1XMOP

PF-10ZURNZ415NDRAIN

P-01

P-02BOBRICKB-165MIRROR

PLUMBING ACCESSORY SCHEDULE

MATERIAL SCHEDULE

WINDOW

CASEWORK SCHEDULE1

PL-2LAMINATENATTEWHITEFORMICA

PT-1PAINTDUNN-EDWARDS

SS-1SOLID

SS-2SOLID

STU-1STUCCO

CASEWORK LEGEND

DEMOLITION NOTES

4.

AND DIRT CONTROL; DISPOSAL OF HAZARDOUS MATERIALS; AND REQUIREMENTS OF THE LOCAL AIR QUALITY MANAGEMENT DISTRICT.

A. ELECTRICAL MECHANICAL EQUIPMENT AND DEVICES: REINSTALL AND PROPERLY RECONNECT EXISTING DUCTWORK; SWITCHES; THERMOSTATS; AND OTHER EXISTING ELEC./MECH., EQUIPMENT AND DEVICES REMOVED DURING THE WORK BUT NOT INDICATED TO BE REMOVED. REINSTALL ONLY EQUIPMENT AND DEVICES THAT ARE IN GOOD CONDITION STATE APPROVAL IS NEEDED FOR MATERIALS THAT ARE TO BE REUSED. DISCARD EQUIPMENT AND DEVICES THAT ARE NOT IN CONDITION AT LEAST AS GOOD AS EXISTED BEFORE REMOVAL, AND PROVIDE NEW EQUIVALENT EQUIPMENT AND DEVICES. NEW EQUIPMENT AND DEVICES SHALL EXACTLY MATCH THOSE REMOVED IN

RENOVATION KEYNOTES

C. WHERE EXISTING PLUMBING VENT PIPES ARE REMOVED FROM THE ROOF AND NEW ONES

FOR MORE INFORMATION. CONCRETE FLOOR AND TILE FINISH SHALL BE SLOPE 1% MIN. AND 2% MAX. TO DRAIN.

22-33NEW SHUT OFF VALVE.SEE PLUMBING DRAWING. 22-34NEW HOSE BIBB.SEE PLUMBING DRAWING.

DOOR HARDWARE

ACCESSORY SCHEDULE

PLUMBING FIXTURE SCHEDULE

EXTERIOR ELEVATION EAST

RENOVATION KEYNOTES

RENOVATION

RENOVATION KEYNOTES

WALL LEGEND

COMMUNITY CENTER FLOOR PLAN B

(E) COMMUNITY ROOM (E) ELECTRICAL ROOM (E) KITCHEN (N) KITCHEN STORAGE (E) ACTIVITY ROOM (N) WOMEN'S RESTROOM

HALLWAY (N) MEN'S RESTROOM (N) WOMEN'S RESTROOM (N) STORAGE (N) MEN'S RESTROOM (N)SHADE STRUCTURE (N)SHADE STRUCTURE (N) JANITOR (N) RESTROOM (E) OFFICE