VA N P O W U P S 1 kVA - 1 0 kVA R a c k & To w e r U P S S y s t e m s
VA N P O W U P S 1 kVA - 1 0 kVA R a c k & To w e r U P S S y s t e m s
Key Advantages - O n - L i n e U P S w i t h R a c k - To w e r Type Design - Pure Sinewave Output with D o u b l e C o n v e r s i o n To p o l o g y - Hot Swappable Battery Replacement for Maintenance - Emergency power off (EPO) protection available VA N P O
W UPS
1 kVA 1 0 kVA R ack & T ower UP S Syste m
- Extendable Backup Time with External Battery Pack Overload, Surge, Short Circuit Protection
VA N P O
s
W UPS
1 kVA 1 0 kVA R ack & T ower UP S Syste m
s
- VPS-1000 / 1500 / 2000 / 3000 / 6 0 0 0 / 1 0 K VA
Th e Va n p o w o n l i n e U P S series with pure sinewave output is the best choice for rack mount or tower based business, IT and telecommunication systems. The high perform a n c e Va n p o w s e r i e s w i t h a power factor of 0.9 and an attached PFC (Power Factor Correction) stabil i z e s fl u c t u a t i n g v o l t a g e , including over voltage and under voltage. The Va n p o w o n l i n e U P S s e r i e s has an easy to read LCD monitor that clearly shows the UPS status and operation controls. A selectable run mode offers h i g h e ffi c i e n c y m o d e a n d free run mode. RAPTOR POWER SYSTEMS
|
(800) 258-0129
|
INFO@RAPTORPOWERSYSTEMS.COM
R A C K M O U N T S P E C I F I C A T I O N
Model Capacity (VA) Capacity (Watts) Form Phase Energy Saving INPUT Voltage 110 Vac
Voltage Range
220 Vac
Frequency Range Power Factor Cold Start OUTPUT Rated Power Factor Waveform Voltage Frequency Transfer Time Harmonic Distortion Crest Factor EPO Function PROTECTION Line Mode Overload
VPR 1000
VPR 1500
1000 900
1500 1350
Quantity Sealed, Maintenance Free Typical Recharge Time External Battery Module External Battery Connector MANAGEMENT Indicator Communication Port SNMP Slot Audible Alarms PHYSICAL Dimensions (WxDxH) (In) Weights (Lbs) Power Module Shipping Dimensions (WxDxH)(In) Weights (Kgs)
VPR VPR VPR 2000 3000 6000 (2U+2U) (2U+2U 2000 3000 2000 3000 6000 1800 2700 1800 2700 5400 Tower or Rack Single Phase Yes - ECO mode Efficiency > 94%
0.9 Pure Sine Wave 100 / 110 / 115 / 120 / 127 / 208 / 220 / 230 / 240 50 / 60 Hz ± 0.25 Hz ≦ 0 ms 2.5% THD at Linear Load 3:01 Option
VPR 10000 10K 9K
208 / 220 / 230 / 240 120 ~ 276 Vac < 25% 140 ~ 276 Vac < 50% 160 ~ 276 Vac < 75% 180 ~ 276 Vac < 100%
208 / 220 / 230 / 240 ≦
3% THD at Linear Load
105% - 120% for 30 seconds 121% - 150% for 10 seconds 101% - 109% for 10 seconds 110% - 120% for 3 seconds IEC 61000-4-5 Level 3 Internal Bypass(Automatic and Manual) UPS Output Cut Off Immediately
Surge Protection Bypass Short Circuit Protection BATTERY
Type
VPR 3000
100 / 110 / 115 / 120 / 127 / 208 / 220 / 230 / 240 60 ~ 144 Vac < 25% Load 70 ~ 144 Vac < 50% Load 80 ~ 144 Vac < 75% Load 90 ~ 144 Vac < 100% Load 120 ~ 276 Vac < 25% Load 140 ~ 276 Vac < 50% Load 160 ~ 276 Vac < 75% Load 180 ~ 276 Vac < 100% Load 50 / 60 Hz (Auto Sensing) > 0.97 Yes
Battery Mode
Model
VPR 2000
VPR1000
VPR1500
12V 7Ah 3
12V 7Ah 4
VPR 2000 12V 7Ah 6
VPR 3000
VPR VPR 2000 3000 (2U+2U) (2U+2U 12V 12V 12V 7Ah 9Ah 7Ah 6 6 8 YES 4 Hr to 90% Option Option
VPR6000 12V 7Ah 20
VPR-10000 12V 9Ah 20
LCD Control Panel RS232, USB(B-type) Option YES 16.9 x 16.8
16.9 x 1 16.9 x 25 x 3.3 9.9
36
39.5
21.5 x 2 1.7 x 8.1
21.7 x 24.5 x 8.7
42.8
46.3
65.7
72
21.7 x 29.5 x 8.7 75
80.7
16.9 x 16.8 x 3.3
16.9 x 23.5
16.9 x 25.9 x 5.2
22.3
44.1
55.1
21.5 x 21.7 x 8.1
22.1 x 29.2 x 10.8
22.3 x 31.7 x 8.2
29.1
53
69
T O W E R S P E C I F I C A T I O N
UPS Model Capacity (VA) Capacity (Watts) Form Phase Energy Saving INPUT Voltage Voltage 110 Vac Range
VPT-1000 1000 900
VPT-1500 1500 1350
VPT-2000 VPT-3000 VPT-6000 2000 3000 6000 1800 2700 5400 Tower Single Phase Yes - ECO mode Efficiency > 94%
100 / 110 / 115 / 120 / 127 or 208 / 220 / 230 / 240 Vac
208 / 220 / 230 / 240 Vac 120 ~ 276 Vac < 25% Load 140 ~ 276 Vac < 50% Load 160 ~ 276 Vac < 75% Load 180 ~ 276 Vac < 100% Load
60 ~ 144 Vac < 25% Load 70 ~ 144 Vac < 50% Load 80 ~ 144 Vac < 75% Load 90 ~ 144 Vac < 100% Load
220 Vac
Frequency Range Power Factor Cold Start OUTPUT Rated Power Factor Waveform Voltage Frequency Transfer Time Harmonic Distortion Crest Factor EPO Function PROTECTION Overloa Line d Mode Battery Mode Surge Protection Bypass Short Circuit Protection BATTERY
VPT-10000 10000 9000
120 ~ 276 Vac < 25% Load 140 ~ 276 Vac < 50% Load 160 ~ 276 Vac < 75% Load 180 ~ 276 Vac < 100% Load 50 / 60 Hz (Auto Sensing) > 0.97 Yes 0.9 Pure Sine Wave 100 / 110 / 115 / 120 / 127 or 208 / 220 / 230 / 240 Vac ± 2% 50 / 60 Hz ± 0.25 Hz ≦ 0 ms 2.5% THD at Linear Load
208 / 220 / 230 / 240 Vac ± 2% ≦
3% THD at Linear Load
3:01 Yes 105% - 120% for 30 seconds 121% - 150% for 10 seconds 101% - 109% for 10 seconds 110% - 120% for 3 seconds IEC 61000-4-5 Level 3 Internal Bypass(Automatic and Manual) UPS Output Cut Off Immediately
T O W E R S P E C I F I C A T I O N
BATTERY Model VPB-1000 VPB-1500 VPB-2000 VPB-3000 VPB-6000 VPB-10K Type 12V 7Ah 12V 7Ah 12V 7Ah 12V 7Ah 12V 7Ah 12V 9Ah Quantity 3 4 6 8 20 20 Sealed, YES Maintenance Free Typical Recharge 4 Hr to 90% Time External Battery Option Module External Battery Option Connector MANAGEMENT Indicator LCD Control Panel Communication RS232, USB(B-type) Port SNMP Slot Option Audible Alarms YES PHYSICAL Power Dimensi 6 x 16.6 10.2 x 23.3 10.2 x 27.2 Module ons 6 x 19.7 x 9.5 7.9 x 16.6 x 14.1 x 9.3 x 23.1 x 22.5 (WxDxH ) (In) Weights 33.5 43 64 66.4 190 213 (Lbs) Shippin g 16.4 x 30 x 16.1 x 34 x Dimensi 11.1 x 21.5 x 11.1 x 24.7 x 13.4 x 20.7 x 19.1 14 14 31.5 31.5 ons (WxDxH )(In) Weights 38.4 47 70 72.5 206 247 (Lbs) * While 208V output, capacity will derated to 90% * Specifications are subject to change without further notice * Specifications are for reference, actual information should be based on real product
VA N P O W U P S 1 kVA - 1 0 kVA R a c k & To w e r U P S S y s t e m s