Skip to main content

ADA Solutions Catalog

Page 1

Proudly Made in the U.S.A.

5

YEAR WARRANTY

WWW.ADATILE.COM • 800-372-0519


1.200 9 - EQUAL SPACES

24.000 21.600 14.400

PART O.A.

PART O.A.

36.000 27.429

Composite Detectable Warning Surfaces for Pedestrian Crossings Table of Contents:

B

B

1.200

2. General Product Information TOP VIEW 1.250 4. Cast-In-Place Replaceable (WET-SET) 34.286 14. Radius Replaceable (WET-SET)15 - EQUAL SPACES VIEW-D 21. Radius Surface Applied 24. Surface Applied (Retrofit) 34. Cast–In–Place (WET-SET) SIDE VIEW 44. About the Law

Meets Compliance Standards as specified by: • Americans with Disabilities Act of 1990 • ADAAG/PROWAG • CA Title 24, CBC 2013 • International Standards Organization, ISO 23599 • Ontarians with Disabilities Act • Canada/CSA–B651

SECTION B-B VIEW -B

Cost Effective, Readily Available .900 and Easy to Install .450 .090 DEG. POINTS .045 HIGH TYP.

DIA. TYP.

60.000° 1.375

0.6250 (6)

0.875 (6)

DIA.(6)

0.200

1.125

DIA.(6)

0.250

0.500

0.562

0.062

0.722

0.967

0.245

DIA. TOP OF DOMES

CAP COVER

323 Andover Street • Suite 3 • Wilmington, MA 01887

R 0.250 TYP.

HEX HEAD BOLTS & WASHER 6-PL.

VIEW -B

Copyright © 2008-2017 ADA Solutions, Inc. All rights reserved.

3 x SIZE


ADAAG/PROWAG/CA Title 24 Compliant – Pleasing architectural quality appearance and high performance product with geometry strictly compliant with all applicable codes. – Approved for use by all major municipalities, DPW’s and state DOT’s.

Homogenous Materials allow for Superior Color Stability Superior Wear Resistance – Wear resistance properties far superior to that achieved with concrete based materials of any type.

Worldwide Distribution

Proudly Made in the U.S.A. – We offer unmatched selection, service, delivery and price, with a strong focus on customer satisfaction. ADA Solutions, Inc. is leading the way in the detectable warning marketplace. Use us once and you’ll see why so many companies across the country choose ADA Solutions, Inc.

Maintenance – Virtually impervious to absorption (key indicator of durability) when compared to concrete, epoxy, or VPC materials. Not affected by chemical exposure. – Easy to clean and replace when necessary.

WWW.ADATILE.COM • 800-372-0519

1


20109

Yellow 33538

Blue

2' x 3' 2' x 4' 2' x 5' 3' x 4' 3' x 5' 2' x 3' 2' x 4' 2' x 5' 3' x 4' 3' x 5'

2.35

31350

Seattle Yellow 23594

2' x 4' 3' x 4' 3' x 5' 2' x 3' 2' x 4' 2' x 5' 3' x 4' 3' x 5'

15 20 24 12 15 18 20 24

2.35

37038

32 25 25 25 25 32 25 25 25 25

670 690 850 1,020 1,250 620 640 830 950 1,170

Pcs/Box

Box Weight*

80 50 50 112 80 80 50 50

1,580 1,460 1,660 1,540 1,485 1,820 1,460 1,710

2' x 2' 2' x 3' 2' x 4' 2' x 5'

6 8 8 11

Weight 2,010 2,070 2,550 2,040 2,500 1,860 1,920 2,480 1,900 2,330

Item No. 2424REP 2436REP 2448REP 2460REP

Pcs/Box 44 32 22 25

Box Weight* 570 560 480 680

Pcs/ Pallet 132 96 66 75

Weight 1,700 1,680 1,450 2,030

Ship Weight

Pcs/Box

Box Weight*

Pcs/ Pallet

Weight

23.40 30.80 38.00 42.80 53.80

25 20 24 14 14

645 680 975 660 815

50 40 48 28 28

1,290 1,350 1,940 1,320 1,630

Ship Weight

Pieces

Weight

14.00 11.00

32 82

510 965

IMPORTANT: We do not double or triple stack Surface Applied Tiles.

A

nc ho

rs

HEAVY-DUTY REPLACEABLES

2.35

Clay Red 22144

19.10 25.20 31.60 38.40 47.60 17.50 23.20 30.60 35.50 44.20

Pcs/ Pallet 96 75 75 50 50 96 75 75 50 50

Ship Weight 11.50 15.60 19.20 24.60

rs A

nc ho

Black

36081

Box Weight*

2448RET1 3648RET1 3660RET1 2436RET2 2448RET2 2460RET2 3648RET2 3660RET2

REPLACEABLES

Dark Gray

Pcs/Box

Part Weight 19.00 28.00 32.00 13.20 17.80 22.00 28.00 33.00

Item No.

A

1.67

Safety Red

Part Weight

SURFACE APPLIED nc ho

15187

Item No. 2436PAV1 2448PAV1 2460PAV1 3648PAV1 3660PAV1 2436PAV2 2448PAV2 2460PAV2 3648PAV2 3660PAV2

rs

Brick Red

CAST-IN-PLACE

1.67

27925

2.35

White

Product Chart

2' x 3' 2' x 4' 2' x 5' 3' x 4' 3' x 5'

8 8 11 9 12

Item No. 2436HDREP 2448HDREP 2460HDREP 3648HDREP 3660HDREP

A

nc ho

rs

RADIUS Replaceable RetroямБt

8 16

* All weights include box & pallets weight.

2

Item No. 248RADREP 24RADRET

Box

Pallet Pieces Weight 96 82

1,520 960

Last Updated: 06/06/2017


USE OF CHEM LINK M-1® ADHESIVE/SEALANT TO INSTALL ADA TACTILE WARNING SURFACE & WAYFINDING PANELS ADA Solutions, Inc. offers the most complete and cost effective composite tactile warning surface (TWS) and wayfinding product line in the industry. ADA the North American market share leader. ADA offers Surface Applied (SA) TWS Panels, Cast-In-Place (CIP) TWS Units, and Replaceable (REP) TWS Units to meet your project requirements. ADA’s TWS products offer outstanding long-term performance, are slip resistant, offer superior long-term color stability, and can be installed with a minimum of effort under a wide variety of conditions. ADA’s products comply with ADAAG, PROWAG, and CA Title 24, CBC–2013 requirements. ADA recommends the use of Chem Link M1 polyether adhesive for installation of its tactile warning surface and wayfinding products.

TYPICAL PHYSICAL PROPERTIES V.O.C. Compliant Color Weight Hardness Flash Point Sheer Strength Elongation Low Temp Flex Cure Time Service Temperature Normal Use Continuous Immersion

Less than 20 grams/liter White, Gray 11.7 lbs per gallon 45+3 Shore A Type N/A 400 PSI 400-550% -10° F 24 hours -40° F to 200° F 120° F

ADH5GAL

• LEED 2.2 for New Construction Major Renovations: Low Emitting Materials (Section 4.1) 1 Point

• NAHB Model Green Home Building Guidelines: 5 Global Impact Points • VOC Content at 240° F: less than 20 grams/liter (including water), ASTM D2369, EPA Method 24

3


Cast-In-Place (wet-set) Replaceable Tactile 4


Proudly Made in the U.S.A.

Each unit comes fully assembled, ready for installation.

5


Cast-In-Place Replaceable Tactile Installation Procedure

(WET-SET)

Be sure to read and understand all of these instructions before you begin.

A. The physical characteristics of the concrete shall be as specified in the contract

documents while maintaining a slump range of 4-7 inches to permit the solid placement of the ADA Cast-In-Place Replaceable Tactile Unit (ADAREP) in the wet cement.

½” x 1½”

B. The concrete shall be poured and finished level, true and smooth to

the required dimensions prior to the placement of the ADAREP unit.

C. Place the ADAREP unit 6-8 inches from the curb line. Working in a

grid pattern, tamp the ADAREP unit into the wet concrete using a rubber mallet and a piece of wood. Continue this process until all of the air has been released, and the ADAREP unit surface is flush with the surrounding area. IMPORTANT: Avoid striking the surface of the ADAREP unit directly.

D. Following the placement, the ADAREP unit elevation should be checked to

Tensile Load Capacity: 6,200 P.S.I. 2” Embedment Depth

the adjacent surface with a straight edge. The ADAREP unit elevation should be consistent with the Contract Drawings and Specifications. Any required adjustments must be made prior to the time when the concrete begins to set.

E. IMPORTANT NOTICE TO INSTALLER: To allow for expansion and contraction, after panel is installed, use a 1/4” finish edge trowel around entire perimeter. On a continous run, be sure to space each unit 1/8” apart.

F. When you are confident that the ADAREP unit is in place and no further adjust-

ments are needed, place a cinder block on both ends to hold the ADAREP unit in place while the concrete sets.

G. During and after the ADAREP unit installation, as well as the concrete curing stage, no walking or external forces can be placed on the ADAREP unit. The area must be protected from pedestrian traffic until concrete is cured. The ADAREP Warning Surface will be ready for pedestrian traffic within 2-4 hours.

H. Be sure to remove plastic protective

PRODUCT SIZES 2’x2’ 2’x3’ 2’x4’ 2’x5’ 3’x4’ 3’x5’

*Not recommended or warrantied for asphalt installation.

APPLICATION Fresh Pour Concrete Ramps & Replacement

covering from the face of the ADAREP Unit once the concrete is cured.

Use an appropriate sized Tactile or Radius Tactile to fit the requirement. If cutting is required, contact manufacturer for more details.

6

WWW.ADATILE.COM • 800-372-0519


Cast-In-Place Replaceable Tactile (WET-SET)

Replacement Procedure

Be sure to read and understand all of these instructions before you begin.

A. Lift the existing composite bolt cap from each anchor location on the ADA Cast-In-Place Replaceable Tactile unit (ADAREP) with a flat head screw driver.

B. Remove the 1/2” x 1½” heavy-duty steel bolts & washers from each anchor location on the ADAREP unit with a ratchet. Save & reuse.

C. Tap around all sides of the ADAREP unit and across the middle with a rubber mallet, working in a grid pattern.

D. Pry the existing ADAREP unit from the concrete ramp with a small prybar, working around the edges until it can be lifted cleanly away.

E. Be sure to remove all debris and dust from the existing impression in the

concrete ramp. IMPORTANT: Be careful not to get debris into anchor locations.

F. Place a new ADAREP unit, of same size and orientation, into impression in

concrete ramp. Lightly tamp down the ADAREP unit with a rubber mallet and a piece of wood. Continue this process until the ADAREP unit is set firmly into existing impression in concrete ramp. IMPORTANT: Avoid striking the ADAREP unit directly.

G. Install 1/2” x 1½” heavy-duty steel bolts & washers back into each anchor location on new ADAREP unit.

H. Insert a new composite bolt cap provided, into each anchor location

on the ADAREP unit. The ADAREP unit is ready for pedestrian traffic immediately after installation is complete.

View additional photos, drawings and specifications on our website: www.adatile.com. Please call (800) 372-0519 with any questions.

WWW.ADATILE.COM • 800-372-0519

7


2 2 1

B

B

Cast-In-Place Replaceable Tactile PATENT PENDING

1.250

34.286

VIEW-D Inline Dome Pattern

15 - EQUAL SPACES

NOTE: US PATENT PENDING APPEARS ON TOP SIDE OF PART AS SHOWN.

(WET-SET)

AIR VENTS AROUND THE OUTSIDE EDGES OF PANEL

In accordance with ADA Regulations for Detectable Warning on Curb Ramps: Raised truncated domes with a diameter of nominal 0.9”, a height of nominal 0.2” and a centerto-center spacing of 2.35”. VIEW -B

PANEL DIMENSIONS .090 DEG. POINTS .045 HIGH TYP.

CAP COVER

.900

Recessed Anchor Location

2.350

DOME GEOMETRY

2.350

0.250

0.250

0.312 0.062

MATERIAL

0.870 0.245 0.200 0.625

0.6250 (4) 0.875 (4)

DIA. TYP. 60.000° ADA Cast-In-Place .500 Replaceable Tactile units (ADAREP) are available in 24” x 24”, DIA. TOP OF DOMES 24” x 36”, 24” x 48”, 24” x 60”, 36” x 48” and1.375 36” DIA. (4) x 60” sizes. ADAREP units may also 1.125 DIA. (4) project requirements. ADAREP units be custom configured to accommodate specific measure ¼” nominal thickness and feature a ¾” thick x 1” wide perimeter “flange.”

A homogenous fiberglass and carbon reinforced composite which is colorfast and UV stable. Truncated domes are fiberglass reinforced for enhanced durability. The color of the ADAREP unit is uniform throughout R0.250 TYP. and does not rely on any type of paint coating to achieve color stability. For superior wheelchair, walker and shopping cart HEX HEAD BOLTS WASHER 4-PL. mobility, truncated domes have a center-to-center (horizontally and &vertically) spacing of 2.35 inches.

PHYSICAL CHARACTERISTICS Compressive Strength Flexural Strength Water Absorption Slip Resistance Flame Spread Index Salt Spray Chemical Stain Testing Abrasion Resistance Accelerated Weathering Tensile Strength Load Bearing at 16,000 lbs. Freeze/Thaw/Heat

28,900 psi 29,300 psi .07% 1.18 Dry, 1.05 Wet 20 No Change (200 hours) No Deterioration 549 Delta E<5.0 (2,000 hours) 11,600 psi No Damage No Disintegration

INSTALLATION

ADA Replacable TWS Unit (New Construction): Each unit comes fully assembled, ready for installation. Replaceable unit can be quickly removed and replaced with hand tools.

ASTM D 695 ASTM D 790 ASTM D 570 ASTM C 1028 ASTM E 84 ASTM B 117 ASTM 1308 ASTM C 501 ASTM G 155 ASTM D 638 AASHTO-H20 ASTM C 1026

5

YEAR WARRANTY

INCIDENTALS

Fasteners: ½” x 1½” heavy-duty steel bolts & washers. Anchors: ½” x 1½” corrosion resistant concrete inserts.

WARRANTY

ADAREP units shall be guaranteed in writing for a period of five (5) years from date of contract’s final completion. The guarantee includes breakage and deformation of the tactile warning surface material.

8

WWW.ADATILE.COM • 800-372-0519

Color Throughout


' '

' '

WWW.ADATILE.COM • 800-372-0519

2424NV6REP_

PART NO.

ADA-REP2424

03-08-17

DATE

(WET-SET)

DRAWING NO.

PART SIZE 24" (610mm) x 24" (610mm) PLANS AND DETAILS

2.35" (59.7mm)IN LINE TRUNCATED DOME

WET SET ADA REPLACEABLE TACTILE WARNING SURFACE UNIT 6-BOLT LOCATIONS

PROJECT

SMC COMPOSITE

MATERIAL

TACTILE WARNING SURFACE

TRADE

ALL DIMENSIONS NOMINAL PRIMARY DIMENSION INCHES mm IN PARENTHESES

Cast-In-Place Replaceable Tactile 24”x24” Tile

2.35” Dome Spacing

9


Cast-In-Place Replaceable Tactile 2.35” Dome Spacing

A 1.250

36.000 27.429

TOP VIEW 34.286

15 - EQUAL SPACES

SIDE VIEW

SECTION A-A

US PATENT # 7,779,581

CAP COVER

TYP.

R0.250

A

*www.adatile.com/patents

NOTE: U.S. Patents*

HEX HEAD BOLTS & WASHER 8-PL.

AIR VENTS LOCATED ON THE ENDS OF THE TWS UNIT

2.350 VIEW - " D" 2 x SIZE FIELD DOT 7 DOME LAYOUT

2.350

1.200 VIEW-D

0.245

60.000° 0.875 (8)

VIEW -B .900

DIA. TYP.

DIA.(8)

1.375

DIA.(8)

1.125

3 x SIZE

0.6250 (8)

0.250

.450

VIEW -B

0.500

.090 DEG. POINTS .045 HIGH TYP.

0.967

1.200 9 - EQUAL SPACES

24.000 21.600 14.400 DIA. TOP OF DOMES

0.22 0.062

0.200 0.722

BOTTOM

VIEW

ALL DIMENSIONS NOMINAL

2436NV8REP_

PART NO.

PRIMARY DIMENSION INCHES mm IN PARENTHESES

TACTILE WARNING SURFACE

TRADE

SMC COMPOSITE

MATERIAL

PROJECT

DATE

WET SET ADA STD REPLACEABLE TACTILE WARNING SURFACE UNIT 8-BOLT LOCATIONS 2.350" IN LINE TRUNCATED DOME PATTERN PART SIZE 24" x 36" PLANS AND DETAILS

ADA-REP2436

DRAWING NO.

(800)372-0519 323 Andover St. Wilmington, MA 01887 info@adatile.com

www.adatile.com

WWW.ADATILE.COM • 800-372-0519

10

(WET-SET)

24”x36” Tile


A

VIEW -B

DIA. TOP OF DOMES

.450

.090 DEG. POINTS .045 HIGH TYP.

VIEW-D

1.250

.900

DIA. TYP.

DIA. (8)

1.125

DIA. (8)

1.375

60.000°

CAP COVER

SECTION A-A

SIDE VIEW

20 - EQUAL SPACES

45.714

TOP VIEW

HEX HEAD BOLTS & WASHER 8-PL.

TYP.

R 0.250

US PATENT # 7,779,581

VIEW - " D" 2 x SIZE FIELD DOT 7 DOME LAYOUT

2.350

AIR VENTS LOCATED ON THE ENDS OF THE TWS UNIT

*www.adatile.com/patents

NOTE: U.S. Patents*

A BOTTOM

TACTILE WARNING SURFACE

2448NV8REP_

PART NO.

DATE

www.adatile.com

(800)372-0519 323 Andover St. Wilmington, MA 01887 info@adatile.com

ADA-REP2448

DRAWING NO.

WET SET ADA REPLACEABLE TACTILE WARNING SURFACE UNIT 8-BOLT LOCATIONS 2.350" IN LINE TRUNCATED DOME PATTERN PART SIZE 24" x 48" PLANS AND DETAILS

PROJECT

SMC COMPOSITE

MATERIAL

TRADE

PRIMARY DIMENSION INCHES mm IN PARENTHESES

ALL DIMENSIONS NOMINAL

VIEW

(WET-SET)

VIEW -B 3 x SIZE

0.500

1.200

9 - EQUAL SPACES

0.967

20.571 2.286 9.1429

0.875 (8)

9.1429

0.6250 (8)

1.200

0.245

48.000

2.350

24.000 21.600 14.400

0.200

0.722

0.22

0.062

WWW.ADATILE.COM • 800-372-0519 0.250 (8)

18.286

Cast-In-Place Replaceable Tactile 24”x48” Tile

2.35” Dome Spacing

11


Cast-In-Place Replaceable Tactile 2.35” Dome Spacing

0.967

6.314

1.250

18.286

.900

60.000°

60.000 13.714

57.143

TOP VIEW 25 - EQUAL SPACES

SIDE VIEW

SECTION B-B

CAP COVER

R0.250 TYP.

HEX HEAD BOLTS & WASHER 11-PL.

18.286 6.314

US PATENT # 7,779,581

B AIR VENTS LOCATED ON THE ENDS OF THE PANEL

*www.adatile.com/patents

NOTE: U.S. Patents*

2.350 VIEW - " D" 2 x SIZE FIELD DOT 7 DOME LAYOUT

2.350

B

VIEW-D

VIEW -B

0.245

DIA. TYP.

DIA.(11)

0.875 (11)

.090 DEG. POINTS .045 HIGH TYP.

0.200 0.722

1.375

DIA.(11)

1.125

0.6250 (11)

0.250 (11)

.450

0.500

1.200 9 - EQUAL SPACES

24.000 21.600 14.400 1.200 DIA. TOP OF DOMES

0.22 0.062

VIEW -B 3 x SIZE

BOTTOM VIEW

ALL DIMENSIONS NOMINAL

2460NV11REP_

PART NO.

PRIMARY DIMENSION INCHES mm IN PARENTHESES

TACTILE WARNING SURFACE

TRADE

SMC COMPOSITE

MATERIAL

PROJECT

DATE

WET SET ADA REPLACEABLE TACTILE WARNING SURFACE UNIT 11-BOLT LOCATIONS 2.350" IN LINE TRUNCATED DOME PATTERN PART SIZE 24" x 60" PLANS AND DETAILS

ADA-REP2460

DRAWING NO.

(800)372-0519 323 Andover St. Wilmington, MA 01887 info@adatile.com

www.adatile.com

WWW.ADATILE.COM • 800-372-0519

12

(WET-SET)

24”x60” Tile


.450

.090 DEG. POINTS .045 HIGH TYP.

0.245

DIA. TOP OF DOMES

0.967

.900

DIA. TYP.

0.562

VIEW -B 3 x SIZE

DIA. (12)

1.125

DIA. (12)

1.375

60.000°

B-B

SIDE VIEW

45.714

20 - EQUAL SPACES

SECTION

0.500

VIEW-B

0.062

PART O.A.

CAP COVER

20.571

0.6250 (12) HEX HEAD BOLTS & WASHER 12-PL.

TYP.

R 0.250

A

AIR VENTS AROUND THE OUTSIDE EDGES OF PANEL

1.143

13.500 13.500

36.000

1.125

33.750

PART O.A.

48.000

0.875 (12)

1.143

0.200

WWW.ADATILE.COM • 800-372-0519

0.722

*www.adatile.com/patents

U.S. Patents*

VIEW - " D" 2 x SIZE FIELD DOT 13 ON DOME LAYOUT

2.350

BOTTOM VIEW

ALL DIMENSIONS NOMINAL

AS NOTED FULL SIZE PART NO.

QT'Y

SEE MATERIAL LIST

PART NO.

REV. NO.

www.adatile.com

(800)372-0519 323 Andover St. Wilmington, MA 01887 info@adatile.com

DRAWING NO.

WET SET ADA REPLACEABLE TACTILE WARNING SURFACE UNIT 2.375" IN LINE TRUNCATED DOME PATTERN PART SIZE 36" x 48" PLANS AND DETAILS

PROJECT

MATERIAL

TRADE DETECTABLE WARNING SURFACE

SCALE

4

3

2

1

ITEM DESCRIPTION

MATERIAL LIST

PRIMARY DIMENSION INCHES mm IN PARENTHESES

(WET-SET)

0.250 (12)

2.286

2.350

15 - EQUAL SPACES

1.125

VIEW-D

A

18.286

Cast-In-Place Replaceable Tactile 36”x48” Tile

2.35” Dome Spacing

13


Cast-In-Place Replaceable Tactile 2.35” Dome Spacing

16.000

59.429

18.286

57.143

20 - EQUAL SPACES

SIDE VIEW

SECTION B-B

1.375

CAP COVER

TYP.

R 0.250

16.000

HEX HEAD BOLTS & WASHER 12-PL.

1.143

AIR VENTS AROUND THE OUTSIDE EDGES OF PANEL

13.500 13.500 "B"

U.S. Patents*

*www.adatile.com/patents

2.350 VIEW - " D" 2 x SIZE FIELD DOT 13 ON DOME LAYOUT

2.350

33.750 "B"

0.245

60.000° DIA. (12) DIA. (12)

1.125

0.875 (12)

1.143

0.200 0.722

1.125 15 - EQUAL SPACES

36.000 PART O.A.

1.125 VIEW-D

VIEW-B .900

DIA. TYP.

0.500

.090 DEG. POINTS .045 HIGH TYP.

.450

0.062

0.562

VIEW -B 3 x SIZE

0.6250 (12)

0.250 (12)

DIA. TOP OF DOMES

0.967

BOTTOM VIEW

ALL DIMENSIONS NOMINAL

SEE MATERIAL LIST

QT'Y

PRIMARY DIMENSION INCHES mm IN PARENTHESES

PART NO.

PART NO.

MATERIAL LIST

ITEM DESCRIPTION

2

1

3

4

SCALE

AS NOTED FULL SIZE

TRADE DETECTABLE WARNING SURFACE

PROJECT

MATERIAL

REV. NO.

WET SET ADA REPLACEABLE TACTILE WARNING SURFACE UNIT 2.375" IN LINE TRUNCATED DOME PATTERN PART SIZE 36" x 60" PLANS AND DETAILS

DRAWING NO.

www.adatile.com

(800)372-0519 323 Andover St. Wilmington, MA 01887 info@adatile.com

WWW.ADATILE.COM • 800-372-0519

14

(WET-SET)

36”x60” Tile


WWW.ADATILE.COM â&#x20AC;¢ 800-372-0519

15


US Patents www.adatile.com/patents

Radius Tactile

cast-in-place replaceable (wet-set) or surface applied

16


Proudly Made in the U.S.A.

Each unit comes fully assembled, ready for installation.

See www.adatile.com for new radius tile calculator!

17


Radius Tactile - Replaceable (WET-SET)

Installation Procedure Be sure to read and understand all of these instructions before you begin.

A. The physical characteristics of the concrete shall be as specified in the contract

documents while maintaining a slump range of 4-7 inches to permit the solid placement of the ADA Radius Replaceable Tactile Unit (ADAREP) in the wet cement.

½” x 1½”

B. The concrete shall be poured and finished level, true and smooth to the required dimensions prior to the placement of the ADAREP unit.

C. Working in a grid pattern, tamp the ADAREP unit into the wet concrete

using a rubber mallet and a piece of wood. Continue this process until all of the air has been released, and the ADAREP unit surface is flush with the surrounding area. IMPORTANT: Avoid striking the surface of the ADAREP unit directly.

D. Following the placement, the ADAREP unit elevation should be checked to

Tensile Load Capacity: 6,200 P.S.I. 2” Embedment Depth

the adjacent surface with a straight edge. The ADAREP unit elevation should be consistent with the Contract Drawings and Specifications. Any required adjustments must be made prior to the time when the concrete begins to set.

E. IMPORTANT NOTICE TO INSTALLER: To allow for expansion and contraction, after panel is installed, use a 1/4” finish edge trowel around entire perimeter. On a continous run, be sure to space each unit 1/8” apart.

F. When you are confident that the ADAREP unit is in place and no further adjustments are needed, place a cinder block on both ends to hold the ADAREP unit in place while the concrete sets.

G. During and after the ADAREP unit installation, as well as the concrete curing stage, no walking or external forces can be placed on the ADAREP unit. The area must be protected from pedestrian traffic until concrete is cured. The ADAREP Warning Surface will be ready for pedestrian traffic within 2-4 hours.

H. Be sure to remove plastic protective

covering from the face of the ADAREP Unit once the concrete is cured.

*Not recommended or warrantied for asphalt installation.

18

PRODUCT SIZES 24” x 33¼” APPLICATION Fresh Pour Concrete Ramps & Replacement

View additional photos, drawings and specifications on our website: www.adatile.com. Please call (800) 372-0519 with any questions.

WWW.ADATILE.COM • 800-372-0519


Radius Tactile - Replaceable (WET-SET)

Replacement Procedure

Be sure to read and understand all of these instructions before you begin.

A. Lift the existing composite bolt cap from each anchor location on the ADA Radius Replaceable Tactile unit (ADAREP) with a flat head screw driver.

B. Remove the 1/2” x 1½” heavy-duty steel bolts & washers from each anchor location on the ADAREP unit with a ratchet. Save & reuse.

C. Tap around all sides of the ADAREP unit and across the middle with a rubber mallet, working in a grid pattern.

D. Pry the existing ADAREP unit from the concrete ramp with a small prybar, working around the edges until it can be lifted cleanly away.

E. Be sure to remove all debris and dust from the existing impression in the

concrete ramp. IMPORTANT: Be careful not to get debris into anchor locations.

F. Place a new ADAREP unit into impression in concrete ramp. Lightly

tamp down the ADAREP unit with a rubber mallet and a piece of wood. Continue this process until the ADAREP unit is set firmly into existing impression in concrete ramp. IMPORTANT: Avoid striking the ADAREP unit directly.

G. Install 1/2” x 1½” heavy-duty steel bolts & washers back into each anchor location on new ADAREP unit.

H. Insert a new composite bolt cap provided, into each anchor location

on the ADAREP unit. The ADAREP unit is ready for pedestrian traffic immediately after installation is complete. US Patents www.adatile.com/patents

View additional photos, drawings and specifications on our website: www.adatile.com. Please call (800) 372-0519 with any questions.

WWW.ADATILE.COM • 800-372-0519

19


Radius Tactile - Replaceable (WET-SET)

Inline Dome Pattern DOME GEOMETRY ADAAG and PROWAG Compliant in-line truncated dome pattern.

UNIVERSAL RADIUS TWS PRODUCT Universal Radius TWS Product is scored for a 10’, 15’ and 20’ radial condition and may be cut to accommodate site conditions. See www.adatile.com for new radius tile calculator.

RADIUS PANEL SIZES • ADA Replaceable TWS Unit: 24” x 33¼”, 8 recessed and capped ½” x 1½” bolts with concrete inserts and heavy duty flange detail.

MATERIAL A homogenous fiberglass and carbon reinforced composite which is colorfast and UV stable. Truncated domes are fiberglass reinforced for enhanced durability. The color of the TWS Unit is uniform throughout and does not rely on any type of paint coating to achieve color stability.

PHYSICAL CHARACTERISTICS Compressive Strength Flexural Strength Slip Resistance Chemical Stain Testing Abrasion Resistance Accelerated Weathering Tensile Strength Load Bearing at 16,000# Freeze/Thaw/Heat

28,900 psi 29,300 psi 1.18 Dry, 1.05 Wet No Deterioration 549 Delta E<5.0 (2,000 hours) 11,600 psi No Damage No Disintegration

ASTM D 695 ASTM D 790 ASTM C 1028 ASTM D 543 ASTM C 501 ASTM G 155 ASTM D 638 AASHTO-H20 ASTM C 1026

INSTALLATION YEAR WARRANTY

Pre-

Scor

ed

5

Color Throughout

20

ADA Radius Replaceable TWS Unit (New Construction): Radius ADAREP unit can be easily installed in wet concrete for applications with outer radius conditions between 6’ to 21’. Each unit comes with pre-scored markings for a 10’, 15’ or 20’ outer radius cut. The unit can be cut on site. Each unit comes fully assembled, ready for installation. Radius ADAREP unit can be quickly removed and replaced with basic handtools.

WARRANTY Radius ADAREP units shall be guaranteed in writing for a period of five (5) years from date of contract’s final completion. The guarantee includes breakage and deformation of the tactile warning surface material.

WWW.ADATILE.COM • 800-372-0519


21


Radius Tactile - Replaceable

ALL DIMENSIONS NOMINAL

PRIMARY DIMENSION INCHES mm IN PARENTHESES

(800)372-0519 323 Andover St. Wilmington, MA 01887 info@adatile.com www.adatile.com

WWW.ADATILE.COM • 800-372-0519

22

(WET-SET)

24”x33.25” Tile 2.35” Dome Spacing


Radius Tactile - Surface Applied Installation Procedure Be sure to read and understand all of these instructions before you begin.

A. The installation area should be cleaned of all debris, oil and grease, making

sure the area is completely free of moisture. Tactile Panel may be surface mounted on existing pre-cleaned substrate.

B. Lay out the Tactile Panel on the substrate as it will appear when installed. • If required, the Tactile Panel may be cut. 10’, 15’, & 20’ radius are pre-scored on backside of tactile panel. See web site for more details.

C. Place a 3/8” bead of adhesive on the frame of the bottom of each Tactile Panel.

D. Set the Tactile Panel in the installation area. Make all necessary adjustments prior to fastening.

E. Fasteners shall be installed in pre-formed fastener locations. Holes shall be

drilled using a hammer drill with 1/4” x 2” min SDS bits. The drilled holes must be a minimum of 2” deep. Place fasteners in hole and hammer into place. • If additional fasteners are required, use a 1/2”, six point, 82 degree countersink to add a new fastener location. Follow the same drilling method for installing the fastener.

F. Caulk around perimeter of entire installation using BASF NP1, Sikaflex 1a or equivalent.

• All concrete dust present on the Tactile Panel resulting from the drilling process must be cleaned off of the Tactile Panel prior to using any caulking materials.

*Not recommended or warrantied for asphalt installation.

View additional photos, drawings and specifications on our website: www.adatile.com. Please call (800) 372-0519 with any questions.

WWW.ADATILE.COM • 800-372-0519

PRODUCT SIZES 24” x 33¼” APPLICATION Existing Concrete Ramps

23


Radius Tactile - Surface Applied Inline Dome Pattern DOME GEOMETRY ADAAG and PROWAG Compliant in-line truncated dome pattern.

UNIVERSAL RADIUS TWS PANEL Universal Radius TWS Panel is scored on backside for a 10’, 15’ and 20’ radial condition and may be cut to accommodate site conditions. See www.adatile.com for new radius tile calculator.

RADIUS PANEL KIT ADA Radius Surface Applied TWS Panel: 24” x 33¼”, 16 composite sleeve anchors with stainless steel pins and 1 tube of adhesive.

MATERIAL A homogenous fiberglass and carbon reinforced composite which is colorfast and UV stable. Truncated domes are fiberglass reinforced for enhanced durability. The color of the TWS Unit is uniform throughout and does not rely on any type of paint coating to achieve color stability.

PHYSICAL CHARACTERISTICS Compressive Strength Flexural Strength Slip Resistance Chemical Stain Testing Abrasion Resistance Accelerated Weathering Tensile Strength Load Bearing at 16,000# Freeze/Thaw/Heat

28,900 psi 29,300 psi 1.18 Dry, 1.05 Wet No Deterioration 549 Delta E<5.0 (2,000 hours) 11,600 psi No Damage No Disintegration

ASTM D 695 ASTM D 790 ASTM C 1028 ASTM D 543 ASTM C 501 ASTM G 155 ASTM D 638 AASHTO-H20 ASTM C 1026

INSTALLATION

5

YEAR WARRANTY

ADA Radius Surface Applied TWS Panel (Existing Construction): Radius Surface Applied Panel can be easily installed (adhered, fastened & sealed) to existing concrete for applications with outer radius conditions between 6’ to 21’. Each unit comes with pre-scored markings for a 10’, 15’ or 20’ outer radius cut. The panel can be cut on site.

Pre-

Scor

ed

INCIDENTALS Fasteners: ¼” x 1½”, composite sleeve anchor with stainless steel pin. Adhesive: One 10-ounce structural elastomeric adhesive. Sealant: BASF NP1, Sikaflex 1a, or equivalent (by others).

WARRANTY Color Throughout

24

Tactile units shall be guaranteed in writing for a period of five (5) years from date of contract’s final completion. The guarantee includes breakage and deformation of the tactile warning surface material.

WWW.ADATILE.COM • 800-372-0519


' B'

0.433 [11.0] O.A. PANEL

24.00 [609.7]

0.188 [4.8]

DETAIL A

1.7 [43.2]

' B'

SECTION-A-A

FRONT VIEW

TOP VIEW

16 - ANCHOR LOCATIONS

27.50 [698.5] REF DIM BEFORE CUT

'B'

33.26 [844.9] REF DIM BEOFRE CUT

0.045 [1.1] POINTS 0.200 [5.1] DOME 150 - PL

WWW.ADATILE.COM • 800-372-0519 0.188 [4.8] PANEL 0.045 [1.1] CUT LINE

'B'

45º

DETAIL B

0.90 [22.9] DIA 150 - PL

0.44 [11.1] DIA.

70º 16 -PL

10’ (3.05m) RADIUS

0.980 [24.9]

0.032 [0.8]

COMPOSITE SLEEVE ANCHOR WITH STAINLESS STEEL NAIL 1 ” X11 ” (6.35mm x 38.1mm) 4 2

1.500 [38.1]

0.440 [11.2]

0.234 [5.9] 0.115 [2.9]

0.058 [1.5]

0.071 [1.8]

BOTTOM VIEW

DETAIL C

0.192 [4.9]

SECTION B-B PANEL INSTALLATION

SIDE VIEW

1' - 11

7

687

6.10

608

595

'B' Dimension (mm) 671

/16"

15

1' - 11 /16"

'B' Dimension 7 2' - 2 /16"

24RADRET_

08-11-16

DATE

(800)372-0519 323 Andover St. Wilmington, MA 01887 info@adatile.com www.adatile.com

ADA-SA24RAD

DRAWING NO.

SURFACE APPLIED TACTILE WARNING SURFACE PANEL 16-ANCHOR LOCATIONS 2.350" (59.7mm) IN LINE TRUNCATED DOME PART SIZE 24"(610mm) x 10'(3.05m), 15'(4.57m), 20'(6.10m) RADIAL PLANS AND DETAILS

PROJECT

SMC COMPOSITE

MATERIAL

PART NO.

# 9,365,984

U.S. PATENT

PRIMARY DIMENSION INCHES mm IN PARENTHESES

ALL DIMENSIONS NOMINAL

METRIC UNIT CHART

702

4.57

'A' Curb Dimension Radius (m) (mm) 3.05 821

TACTILE WARNING SURFACE

TRADE

2' - 3 /16"

1

2' - 3 /8"

5

'A' Dimension 5 2' - 8 /16"

IMPERIAL UNIT CHART

20'

15'

Curb Radius 10'

Radius Tactile - Surface Applied 24”x33.25” Tile 2.35” Dome Spacing

2.35 [59.7]

25


Surface Applied Tactile 26


Proudly Made in the U.S.A.

27


Surface Applied Tactile Installation Procedure Be sure to read and understand all of these instructions before you begin.

A. The installation area should be cleaned of all debris, oil and grease, making sure the area is completely free of moisture. Tactile Panel may be surface applied on existing pre-cleaned substrate.

B. Lay out the Tactile Panel on the substrate as it will appear when installed. • If required, the Tactile Panel may be cut. See web site for more details.

C. Place a 3/8” bead of adhesive on the frame of the bottom of each Tactile Panel.

2’x3’

2’x4’

2’x5’

require one 10-ounce tube of adhesive

3’x4’

3’x5’

require two 10-ounce tubes of adhesive

D. Set the Tactile Panel in the installation area. Make all necessary adjustments prior to fastening.

E. Fasteners shall be installed in pre-formed fastener locations. Holes shall be

drilled using a hammer drill with 1/4” x 2” min SDS bits. The drilled holes must be a minimum of 2” deep. Place fasteners in hole and hammer into place. • If additional fasteners are required, use a 1/2”, six point, 82 degree countersink to add a new fastener location. Follow the same drilling method for installing the fastener.

F. Caulk around perimeter of entire installation using BASF NP1, Sikaflex 1a or equivalent. • All concrete dust present on the Tactile Panel resulting from the drilling process must be cleaned off of the Tactile Panel prior to using any caulking materials.

*Not recommended or warrantied for asphalt installation.

View additional photos, drawings and specifications on our website: www.adatile.com. Please call (800) 372-0519 with any questions.

28

WWW.ADATILE.COM • 800-372-0519

PRODUCT SIZES 2’x3’ 2’x4’ 2’x5’ 3’x4’ 3’x5’ APPLICATION Existing Concrete Ramps


Surface Applied Tactile Inline Dome Pattern DOME GEOMETRY

In accordance with ADA Regulations for Detectable Warning on Curb Ramps: Raised truncated domes with a diameter of nominal 0.9”, a height of nominal 0.2”, and a centerto-center spacing of nominal 1.67” minimum and 2.35” maximum.

PANEL DIMENSIONS

Tactile Panels are available in 24”x36”, 24”x48”, 24”x60”, 36”x48” and 36”x60” sizes and measure 3/16” thick. Panels can be custom cut to fit field conditions. All four edges of each panel have a ½” beveled edge. Each panel has 12 to 24 pre-formed fastener locations based upon panel size.

MATERIAL

A homogenous fiberglass and carbon reinforced composite which is colorfast and UV stable.Truncated domes are fiberglass reinforced for enhanced durability. The Tactile panel color is uniform throughout and does not rely on any type of paint coating to achieve color stability.

PHYSICAL CHARACTERISTICS Compressive Strength Flexural Strength Water Absorption Slip Resistance Flame Spread Index Salt Spray Chemical Stain Testing Abrasion Resistance Accelerated Weathering Tensile Strength Adhesion to Conc. (20-180 degrees) Freeze/Thaw/Heat

28,900 psi 29,300 psi .07% 1.18 Dry/1.05 Wet 20 No Change (200 hours) No Deterioration 549 Delta E<5.0 (2,000 hours) 11,600 psi No Delamination or Degradation No Disintegration

INSTALLATION

ADA Surface Applied TWS Panel (Existing Concrete): TWS panel can be easily installed (adhered, fastened & sealed) in a matter of minutes.

ASTM D 695 ASTM D 790 ASTM D 570 ASTM C 1028 ASTM E 84 ASTM B 117 ASTM 1308 ASTM C 501 ASTM G 155 ASTM D 638 ASTM C 903 ASTM C 1026

5

YEAR WARRANTY

INCIDENTALS

Fasteners: ¼” x 1½” composite sleeve anchor with stainless steel pin. Adhesive: Structural elastomeric adhesive. 2’x3’

2’x4’

2’x5’

require one 10-ounce tube of adhesive

3’x4’

3’x5’

require two 10-ounce tubes of adhesive

Color Throughout

Sealant: BASF NP1, Sikaflex 1a, or equivalent (by others).

WWW.ADATILE.COM • 800-372-0519

29


Surface Applied Composite Tactile 24”x36” Tile

2.35” Dome Spacing

ALL DIMENSIONS NOMINAL

PRIMARY DIMENSION INCHES mm IN PARENTHESES

(800)372-0519 323 Andover St. Wilmington, MA 01887 info@adatile.com www.adatile.com

WWW.ADATILE.COM • 800-372-0519

30


ALL DIMENSIONS NOMINAL

WWW.ADATILE.COM • 800-372-0519

(800)372-0519 323 Andover St. Wilmington, MA 01887 info@adatile.com www.adatile.com

PRIMARY DIMENSION INCHES mm IN PARENTHESES

Surface Applied Composite Tactile 24”x48” Tile

2.35” Dome Spacing

31


Surface Applied Composite Tactile 24”x60” Tile

2.35” Dome Spacing

ALL DIMENSIONS NOMINAL

PRIMARY DIMENSION INCHES mm IN PARENTHESES

(800)372-0519 323 Andover St. Wilmington, MA 01887 info@adatile.com www.adatile.com

WWW.ADATILE.COM • 800-372-0519

32


ALL DIMENSIONS NOMINAL

WWW.ADATILE.COM • 800-372-0519

(800)372-0519 323 Andover St. Wilmington, MA 01887 info@adatile.com www.adatile.com

PRIMARY DIMENSION INCHES mm IN PARENTHESES

Surface Applied Composite Tactile 36”x48” Tile

2.35” Dome Spacing

33


Surface Applied Composite Tactile 36”x60” Tile

2.35” Dome Spacing

ALL DIMENSIONS NOMINAL

PRIMARY DIMENSION INCHES mm IN PARENTHESES

(800)372-0519 323 Andover St. Wilmington, MA 01887 info@adatile.com www.adatile.com

WWW.ADATILE.COM • 800-372-0519

34


35


Cast-In-Place (wet-set) Tactile 36


Proudly Made in the U.S.A.

37


Cast-In-Place Tactile Installation Procedure

(WET-SET)

Be sure to read and understand all of these instructions before you begin.

A. The

physical characteristics of the concrete shall be as specified in the contract documents while maintaining a slump range of 4-7 to permit the solid placement of the Tactile Unit in the wet cement.

B. The concrete shall be poured and finished level, true and smooth to the required dimensions prior to the placement of the Tactile Unit.

C. Place the Tactile Unit 6-8 inches from the curb line. Working in a grid pat-

tern, tamp the Tactile Unit into the wet concrete using a rubber mallet and a piece of wood. Continue this process until all of the air has been released, and the Tactile Unit surface is flush with the surrounding area. IMPORTANT: Avoid striking the surface of the Tactile Unit directly.

D. Following the placement, the Tactile Unit elevation should be checked to the adjacent surface with a straight edge. The Tactile Unit elevation should be consistent with the contract drawings and specifications. Any required adjustments must be made prior to the time when the concrete begins to set.

E. IMPORTANT NOTICE TO INSTALLER: To allow for expansion

and contraction, after tile is installed, use a 1/4” finish edge trowel around entire perimeter. On a continous run, be sure to space each unit 1/8” apart.

F. When you are confident that the Tactile Unit is in place, and

no further adjustments are needed, place a cinder block on both ends to hold the Tactile Unit in place while the concrete sets.

G. During and after the Tactile Unit installation, as well as the

concrete curing stage, no walking or external forces can be placed on the Tactile Unit. The area must be protected from pedestrian traffic until concrete is cured. The Tactile Warning Surface will be ready for pedestrian traffic within 2-4 hours.

H. Be sure to remove plastic protective covering from the face of the Tactile Unit once the concrete is cured.

Use an appropriate sized Tactile to fit the requirement. If cutting is required, contact manufacturer for more details. View additional photos, drawings and specifications on our website: www.adatile.com. Please call (800) 372-0519 with any questions.

38

WWW.ADATILE.COM • 800-372-0519

PRODUCT SIZES 2’x3’ 2’x4’ 2’x5’ 3’x4’ 3’x5’ APPLICATION Fresh Pour Concrete Ramps


Cast-In-Place Tactile (WET-SET)

Inline Dome Pattern

DOME GEOMETRY

In accordance with ADA Regulations for Detectable Warning on Curb Ramps: Raised truncated domes with a diameter of nominal 0.9”, a height of nominal 0.2”, and a center-to-center spacing of 1.67” minimum and 2.35” maximum.

PANEL DIMENSIONS

Tactile Units are available in 2’x3’ , 2’x4’ , 2’x5’ , 3’x4’ and 3’x5’ sizes. Tactile Units may also be custom configured to accommodate specific project requirements. Tactile Units measure 0.25” nominal thickness and feature embedment ribs at 3” on center.

MATERIAL

A homogenous fiberglass and carbon reinforced composite which is colorfast and UV stable. Truncated domes are fiberglass reinforced for enhanced durability. The color of the Tactile Unit is uniform throughout and does not rely on any type of paint coating to achieve color stability.

INSTALLATION

Cast-In-Place Tactile Units are to be used on new curb ramp locations.

PHYSICAL CHARACTERISTICS Compressive Strength Flexural Strength Water Absorption Slip Resistance Flame Spread Index Salt Spray Chemical Stain Testing Abrasion Resistance Accelerated Weathering Tensile Strength Load Bearing at 16,000 lbs. Freeze/Thaw/Heat

28,900 psi 29,300 psi .07% 1.18 Dry, 1.05 Wet 20 No Change (200 hours) No Deterioration 549 Delta E<5.0 (2,000 hours) 11,600 psi No Damage No Disintegration

ASTM D 695 ASTM D 790 ASTM D 570 ASTM C 1028 ASTM E 84 ASTM B 117 ASTM 1308 ASTM C 501 ASTM G 155 ASTM D 638 AASHTO-H20 ASTM C 1026

5

Color Throughout

WWW.ADATILE.COM • 800-372-0519

YEAR WARRANTY

39


Cast-In-Place Tactile

ALL DIMENSIONS NOMINAL

PRIMARY DIMENSION INCHES mm IN PARENTHESES

(800)372-0519 323 Andover St. Wilmington, MA 01887 info@adatile.com www.adatile.com

WWW.ADATILE.COM • 800-372-0519

40

(WET-SET)

24”x36” Tile

2.35” Dome Spacing


ALL DIMENSIONS NOMINAL

(WET-SET)

WWW.ADATILE.COM • 800-372-0519

(800)372-0519 323 Andover St. Wilmington, MA 01887 info@adatile.com www.adatile.com

PRIMARY DIMENSION INCHES mm IN PARENTHESES

Cast-In-Place Tactile 24”x48” Tile

2.35” Dome Spacing

41


Cast-In-Place Tactile

ALL DIMENSIONS NOMINAL

PRIMARY DIMENSION INCHES mm IN PARENTHESES

(800)372-0519 323 Andover St. Wilmington, MA 01887 info@adatile.com www.adatile.com

WWW.ADATILE.COM • 800-372-0519

42

(WET-SET)

24”x60”

2.35” Dome Spacing


ALL DIMENSIONS NOMINAL

(WET-SET)

WWW.ADATILE.COM • 800-372-0519

(800)372-0519 323 Andover St. Wilmington, MA 01887 info@adatile.com www.adatile.com

PRIMARY DIMENSION INCHES mm IN PARENTHESES

Cast-In-Place Tactile 36”x48” Tile

2.35” Dome Spacing

43


Cast-In-Place Tactile

ALL DIMENSIONS NOMINAL

PRIMARY DIMENSION INCHES mm IN PARENTHESES

(800)372-0519 323 Andover St. Wilmington, MA 01887 info@adatile.com www.adatile.com

WWW.ADATILE.COM • 800-372-0519

44

(WET-SET)

36”x60” Tile

2.35” Dome Spacing


45


About

the

Law

Summary To view ADAAG and PROWAG requirements, go to www.ADATILE.com

REVISED DRAFT GUIDELINES: Accessibility Guidelines for Pedestrian Facilities in the Public Right-of-Way (July 26, 2011)

R305 Detectable Warning Surfaces R305.1 General. Detectable warnings shall consist of a surface of truncated domes aligned in a square or radial grid pattern and shall comply with R304. R305.1.1 Dome Size. Truncated domes in a detectable warning surface shall have a base diameter of 23 mm (0.9 in) minimum to 36 mm (1.4 in) maximum, a top diameter of 50 percent of the base diameter minimum to 65 precent of the base diameter maximum, and a height of 5 mm (0.2 in). R305.1.2 Dome Spacing. Truncated domes in a detectable warning surface shall have a centerto-center spacing of 41 mm (1.6 in) minimum and 61 mm (2.4 in) maximum, and a base-tobase spacing of 17 mm (.65 in) minimum, measured between the most adjacent domes. R305.1.3 Contrast. Detectable warning surfaces shall contrast visually with adjacent gutter, street or highway, or walkway surface, either light-on-dark, or dark-on-light. R305.1.4 Size. Detectable warning surfaces shall extend 610 mm (24 in) minimum in the direction of travel and the full width of the curb ramp (exclusive of flares), the landing, or the blended transition. R305.2 Location and Alignment R305.2.1 Perpendicular Curb Ramps. Where both ends of the bottom grade break complying with R303.3.4 are 1.5 m (5.0 ft) or less from the back of the curb, the detectable warning shall be located on the ramp surface at the bottom grade break. Where either end of the bottom grade break is more than 1.5 m (5.0 ft) from the back of the curb, the detectable warning shall be located on the lower landing. R305.2.2 Landings and Blended Transitions. The detectable warning shall be located on the landing or blended transition at the back of the curb. R305.2.3 Alignment. The rows of truncated domes in a detectable warning surface shall be aligned to be perpendicular or radial to the grade break between the ramp, landing, or blended transition and the street.

46

WWW.ADATILE.COM â&#x20AC;˘ 800-372-0519


WWW.ADATILE.COM â&#x20AC;¢ 800-372-0519

47


48

WWW.ADATILE.COM â&#x20AC;¢ 800-372-0519


The Only Complete Detectable Warning and Wayfinding Solution for the Visually Impaired

49


WWW.ADATILE.COM â&#x20AC;¢ 800-372-0519

6/17


Turn static files into dynamic content formats.

Create a flipbook