Information Guide
www.r-anell.com
Warranty 1-Year Limited Warranty The Commodore Corporation or its subsidiaries warrants this manufactured home to be free from substantial defects of material or workmanship under normal use and service for a period of one (1) year from date of delivery to the FIRST RETAIL PURCHASER, subject to the conditions set forth in this warranty. Defects of material or workmanship reported under the terms of this warranty will be repaired or replaced at the manufacturer’s discretion without charge to the owner for parts or labor. Should any defect occur, not excluded under the EXCLUSIONS, LIMITATIONS, and RESTRICTIONS set forth below, written notice must be given not later than one (1) year and ten (10) days following the date of delivery to the first retail purchaser. The written notice should first be sent to the dealer that sold you your home. If the repairs are not made to your satisfaction, then please forward a copy of your request to the Commodore plant whose address is shown on the front cover of your Home Owner’s Manual. This warranty DOES NOT INCLUDE: 1. Coverage to correct defects or damage attributable to owners negligence or misuse, unauthorized repairs, accidents, alterations or modifications that were made after the date of delivery to the first retail customer. 2. Coverage due to failure to follow any instructions set forth in the HOME OWNER’S MANUAL and INSTALLATION INSTRUCTIONS. 3. Coverage to correct defects attributable to improper transportation, set-up, blocking or leveling of the home. 4. Coverage to correct defects in appliances or other products whose manufacturers provide a separate warranty. These warranties have been provided to you and their procedures should be followed. 5. Coverage to furniture, drapes, beds and bedding, unless noted during initial inspection of the home. 6. Coverage to any equipment, appliances or other features of your home not installed by Commodore, whether installed by the dealer or any other person. 7. Coverage under this warranty shall apply only to the FIRST RETAIL PURCHASER of the home. It is not transferable. Further, there is no coverage for commercial use. If the home is used for commercial use prior to a sale to the first retail purchaser, the warranty is void. 8. COMMODORE SHALL NOT BE LIABLE FOR INCIDENTAL OR CONSEQUENTIAL DAMAGES, including, but not limited to, loss of time, inconvenience, hotel bills, telephone calls, spoiled goods and lost wages. (Some states do not allow the exclusion or limitation of incidental or consequential damages, so the preceding limitation or exclusion may not apply to you.) OTHER THAN AS SET FORTH ABOVE, COMMODORE MAKES NO OTHER EXPRESS WARRANTY WITH RESPECT TO THIS HOME AND NO PERSON OR DEALER IS AUTHORIZED TO MAKE ANY REPRESENTATION, WARRANTY OR PROMISE ON BEHALF OF COMMODORE. ANY IMPLIED WARRANTIES OF MERCHANTABILITY AND FITNESS FOR A PARTICULAR PURPOSE ARE LIMITED TO ONE YEAR. (Some states do not allow the exclusion or limitation on how long an implied warranty lasts, so the preceding limitation or exclusion may not apply to you.) THIS WARRANTY GIVES YOU SPECIFIC RIGHTS, AND YOU MAY ALSO HAVE OTHER RIGHTS WHICH VARY FROM STATE TO STATE. No action to enforce this warranty shall be commenced later than six (6) months after the expiration of the warranty period. Commodore reserves the unrestricted right at any time make changes in the design and improvements of its products without thereby imposing any obligation upon itself to make corresponding changes or improvements in or upon products heretofore manufactured.
Original Written - 5/13/02
WA-1
4/2017
Warranty 2-10 Home Buyers Warranty Information 10-Year Structural Warranty - $500,000 Warranty Limit
WA-2
4/2017
Warranty 2-10 Home Buyers Warranty Information 10-Year Structural Warranty - $500,000 Warranty Limit
WA-3
4/2017
Warranty 2-10 Home Buyers Warranty Information 10-Year Structural Warranty - $500,000 Warranty Limit
WA-4
4/2017
Series Information Blueridge Series Standard Specifications 10 Year Limited Structural Warranty INTERIOR Primed Smooth Drywall Throughout Flat Ceiling Throughout Smooth Ceiling 8’0” Ceiling Height Live Wire Carpet Protected with Shaw Stain Safety Rebond Carpet Pad Tackstrip Carpet Installation No-Wax Vinyl Floor Coverings by Congoleum Langford 3-Arm Dining Room Light Recessed 6” LED Lighting in Nook 6-Panel Pre-Hung Doors Mortise Door Hinges Metal Interior Passage Sets Door Stops Smoke Detectors with Battery Back-Up Wire Shelving in Guest Closet & Utility Room 2 1/4” Window & Door Trim White Painted Mouldings Throughout Laminate Countertops with Laminate Edging 4” Laminate Backsplash
KITCHEN Stainless Steel 33x19x7 Sink Empire Brushed Nickel Single Lever Faucet USB Receptacle Deluxe Free Standing Electric Range
CABINETRY Evermore Custom Cabinetry (KCMA Certified) Hardwood Mission Cabinet Doors w/ Full Overlay Hardwood Cabinet Face Frames & Stiles Brushed Nickel Cabinet Hardware Concealed Cabinet Hinges Dovetail Drawers w/ Undermount Drawer Guides 30” Wall Cabinets Adjustable Shelves in Wall Cabinets Adjustable Center Shelf in Base Cabinets Standard Islands in Most Models Base Shelf in Vanities 36” High Vanities
UTILITIES 200 AMP Electrical Service Arc Fault Circuit Breakers Plumb and Wire for Washer Wire and Vent for Dryer 40 Gallon Electric Water Heater with Pan 6-Panel Furnace Door Air Ready Electric Furnace Fiberglass Heat Ducts Copper Wiring Throughout Main Water Line Shut-Off Valve Water Shut-Off Valves Where Accessible One Exterior Water Faucet Uponor Plumbing System Recessed Dryer Vent Box - Where Available Drain & Gas Lines Stubbed Through Floor Complete Heat System
BEDROOMS Switched Receptacles Egress Window Each Bedroom Wire Shelves in all Walk-In Closets Wire Shelving in Secondary Closets 30” Interior Passage Doors Switched Recessed 4” LED Light in All Walk-In Closets Privacy Sets in all Bedrooms
BATHS 60” x 42” Fiberglass Garden Tub in Master Bath 60” One-Piece Fiberglass Tub/Shower in 2nd Bath One-Piece Fiberglass Shower with Glass Door in Glamour Baths Tub Overflows 1.6 Gallon Per Flush Elongated Toilets China Stool, Tank and Lid China Sinks with Overflows and Pop-Up Drains Lighted Vent Fan in Each Bath Soffit w/ Recessed LED Lights over Vanity in Master Bath Langford 2-Arm Vanity Light Empire Brushed Nickel Faucets Anti-Scald Valves on Showers Privacy Sets in all Bathrooms In-Wall Toilet Riser
EXTERIOR Patina Lantern Light at Front Door Square Lantern Light at Rear Door Two GFI-Protected Exterior Receptacles Vinyl Dutch Lap Siding O.S.B. Sheathing Under Siding 5/12 Roof Pitch 10” or 12” Overhangs & Eaves (Depending on Model) 3-Tab Shingles Ridgevent Roof Ventilation System 38x82 Fiberglass 6-Panel Front & Rear Doors with Deadbolt Locks Vinyl Insulated Windows with Low-E Glass 15” Raised Panel Shutters on Front Door Side Wind Wrap Vapor Barrier CONSTRUCTION 2x10 Transverse Floor System with 3/4” T&G O.S.B. Floor Decking 2x4 Exterior Walls – 25/38 Wide Homes 2x6 Exterior Walls – 28/32/42 Wide Homes 2x4 Marriage Walls 90 Mile Exposure C Wind Load Design 20# Roof Load Design 82 1/2” Window Headers Virginia Built Homes R-30 Fiberglass Insulation in Floor R-19 Fiberglass Insulation in Wall R-38 Avg. Blown Insulation in Ceiling Foam Gaskets at Switches & Recepts on Exterior Walls Insulated Hot Water Lines Deleted Factory Installed Heat Ducts and Boots
INSULATION R-19 Fiberglass Insulation in Floor R-13 Fiberglass Insulation in Walls – 25/38 Wide Homes R- 19 Fiberglass Insulation in Walls – 28/32/42 Wide Homes R-31 Avg. Blown Insulation in Ceiling
SI-1
4/2017
Series Information Rockbridge Series Standard Specifications 10 Year Limited Structural Warranty INTERIOR Primed Smooth Drywall Throughout Flat Ceiling Throughout Stipple Ceiling 8’0” Ceiling Height Carpet with ShawGuard Carpet Protector Rebond Carpet Pad Tackstrip Carpet Installation Entry Foyer with Vinyl Flooring No-Wax Vinyl Floor Coverings by Congoleum Langford 3-Arm Dining Room Light Alabaster Glass Pendant Nook Light Glass Light Shades Throughout 3 1/4” Window & Door Trim 6-Panel Pre-Hung Doors with Mortise Hinges White Painted Mouldings Throughout Metal Interior Passage Sets Floor Mount Door Stops Smoke Detectors with Battery Back-Up Wire Shelving in Guest Closet & Utility Room 2” Window Blinds Throughout Nailed on Switch and Recept. Boxes Laminate Countertops with Laminate Edging 4” Laminate Backsplash CABINETRY Evermore Custom Cabinetry (KCMA Certified) Hardwood Mission Cabinet Doors with Full Overlay Hardwood Cabinet Face Frames Brushed Nickel Cabinet Hardware Concealed Cabinet Hinges Crown Moulding on Wall Cabinets 30”/36” Staggered Wall Cabinets Adjustable Shelves in Wall Cabinets Undermount Drawer Guides with Dovetail Drawers Adjustable Center Shelf in Base Cabinets 36” High Bath Vanities with Base Shelf KITCHEN Stainless Steel Sink - 33x22x8 Huntington Brass Nickel Single Lever Faucet USB Receptacle Deluxe Free-Standing Electric Range Power Range Hood with Light 18 Cubic Foot, No-Frost Refrigerator Island with Stile Framed Panels on Sides & Backs
BATHS 60” One-Piece Fiberglass Tub/Showers with Ceramic Tile Edge One-Piece Fiberglass Shower with Ceramic Tile Edge and a Glass Door in Glamour Baths Fiberglass Soaker Tub In Glamour Baths Tub Overflows End Drain on Tubs/Showers 1.6 Gallon Per Flush Elongated Toilets China Stool, Tank & Lid China Sinks with Overflows and Pop-Up Drains Lighted Vent Fan in Each Bath Huntington Brass Nickel Faucets Anti-Scald Valves on Showers & Tubs Langford 2- Arm Vanity Light Privacy Lock Sets in all Bathrooms BEDROOMS Ceiling Lights Egress Window Each Bedroom Double Wire Shelves with Shoe Racks in All Walk-In Closets Wire Shelving in Secondary Closets 30” Interior Passage Doors Switched Recessed 4” LED Light in All Walk-In Closets Privacy Lock Sets in all Bedrooms UTILITIES 200 AMP Electrical Service Arc Fault Circuit Breakers Plumb and Wire for Washer Wire and Vent for Dryer 40 Gallon Electric Water Heater with Pan Air Ready Electric Furnace Six Panel Furnace Door Perimeter Heat, Fiberglass Ducts, & Return Air System Copper Wiring Throughout Main Water Line Shut-Off Valve Water Shut-Off Valves Where Accessible One Exterior Water Faucet Recessed Dryer Vent Box - Where Available Uponer Plumbing Connections Drain & Gas Lines Stubbed Through Floor Complete Heat System Ceiling Jumper Box HVAC Return Air System
EXTERIOR Patina Lantern Light at Front & Rear Door Two GFI-Protected Exterior Receptacles Vinyl Dutch Lap Siding O.S.B. Sheathing Under Siding 5/12 Roof Pitch 10” or 12” Overhangs & Eaves (Depending on Model) Architectural Shingles Ridgevent Roof Ventilation System 38x82 Fiberglass 6-Panel Front Door with Dead Bolt 38x82 9-Lite Fiberglass Rear Door with Dead Bolt Vinyl Insulated Windows with Low-E Glass 15” Raised Panel Shutters on Front Door Side Wind Wrap Vapor Barrier CONSTRUCTION 2x10 Transverse Floor System on 16” Centers with 3/4” T&G O.S.B. Floor Decking** Toilet Riser in Wall 2x6 Exterior Walls on 16” Centers** 2x4 Interior Walls 2x4 Marriage Walls 82 1/2” Window Headers 90 MPH Exposure B Wind Load 20# Roof Load Design Virginia Built Homes R-30 Fiberglass Insulation in Floor R-19 Fiberglass Insulation in Wall R-38 Avg. Blown Insulation in Ceiling Foam Gaskets at Switches & Recepts on Exterior Walls Insulated Hot Water Lines Deleted Factory Installed Heat Ducts and Boots
**Spacing for Framing Members may vary due to Design Requirements
INSULATION R-19 Fiberglass Insulation in Floor R-19 Fiberglass Insulation in Walls R-31 Avg. Blown Insulation in Ceiling
SI-2
4/2017
Series Information Rockbridge Elite Series Standard Specifications In addition to Rockbridge Standard Specifications, Elite Series will have the following items as Standard 9’ Sidewall 68” Windows 42”/30” Kitchen Cabinet Stagger Appliance Garage Under Cabinet Moulding Drawer Over Door Cabinetry 15 Lite Rear Door Laminate Wood Floor Kitchen/Nook/Foyer/Dining (Plan Specific) Beverage Center Full Ceramic Backsplash in Kitchen 10 Recessed LED Lights in Kitchen Gooseneck Kitchen Faucet Coveless Smooth Ceiling Tray Ceiling in Dining Room with 2 Beams & 6 Recessed LED Lights Backsplash in Master Bath 4x6 Ceramic Tile Shower, 2 Shower heads 2 Recessed LED Lights in Master Bedroom Closet Garden Tub in 2nd Bath (Plan Specific) Transom Window in 2nd Bath (Plan Specific) Contemporary Cabinet Pulls on Doors and Knobs on Drawers Deluxe Ceiling Fan (2) 3-Way Switches in Living Room Smooth Surface Burner Cook Top Chef ’s Signature Range Hood Microwave and Wall Oven Dishwasher 25 Cf. Stainless Steel Refrigerator
SI-3
4/2017
Series Information Summit Series Standard Specifications 10 Year Limited Structural Warranty Interior Primed Smooth Drywall Throughout Flat Ceiling Throughout Smooth Finish Coveless Ceiling 9’-0” Ceiling Height 25 oz. Carpet with ShawGuard Carpet Protector Rebond Carpet Pad Wet Areas Nafco16x16 Floor Tiles or Volare Plank Flooring Langford 5-Arm Dining Room Light Langford 3-Arm Alabaster Glass Nook Light Pre-Hung Doors w/ Mortise Hinges Crafstman White 5-Panel Interior Doors Metal Interior Passage Sets Floor Mount Door Stops Smoke Detectors with Battery Back-Up Wire Shelving in Guest Closet & Utility Room Craftsman White Painted Mouldings Square Stairwell Railing & Posts Laminate Countertops with Crescent Edging Laminate Backsplash Kitchen Recessed 6” LED Lighting USB Receptacle 30” Deluxe Free-Standing Electric Range Power Range Hood with Light 18 Cubic Foot, No-Frost Refrigerator Drop-In Offset Double Bowl Sink Brushed Nickel Coil Spring Goose Neck Faucet Cabinetry Evermore Custom Cabinetry (KCMA Certified) Hardwood Mission Cabinet Doors with Full Overlay Hardwood Cabinet Face Frames Brushed Nickel Cabinet Hardware Concealed Cabinet Hinges Undermount Roller Guide Drawer System Dovetail Drawers Kitchen Island w/ 3” Stile Framed Panels on Sides & Back Lined Overhead Cabinets Crown Moulding on Overhead Cabinets Hardwood Undercabinet Moulding in Kitchen 42” Overhead Cabinets Adjustable Shelves in Overhead Cabinets Bumped Out Kitchen Sink Cabinet Base Shelf in Vanities 36” High Bath Vanities
Baths 60” One-Piece Fiberglass Tub/ Showers with Ceramic Tile Edge One-Piece Fiberglass Shower with Ceramic Tile Edge and a Glass Door in Glamour Baths Fiberglass Soaker Tub in Glamour Baths Tub Overflows 1.6 Gallon Per Flush Elongated Toilets China Stool, Tank and Lid China Sinks with Overflows and Pop-Up Drains 2-Arm Vanity Light Lighted Vent Fan in Each Bath Huntington Brass Sherington Faucets Anti-Scald Valves on Showers
Utilities 200 AMP Electrical Service Arc Fault Circuit Breakers 5-Wire A/C Thermostat Plumb and Wire for Washer Wire and Vent for Dryer Perimeter Boots & Registers Box Air Return System Through Floor 50 Gallon Electric Water Heater with Pan Copper Wiring Throughout Main Water Line Shut-Off Valve Water Shut-Off Valves Where Accessible Drain Lines Stubbed Though Floor One Exterior Water Faucet Recessed Dryer Vent Box - Where Available
Construction 2x10 Transverse Floor System on Bedrooms 16”Centers with 3/4” T&G O.S.B. Floor Ceiling Lights Decking** Egress Window in Each Bedroom Toilet Riser in Wall Wire Shelving in Secondary Closets 2x6 Exterior Walls Switched 4” LED Light in All Walk-In Closets 2x4 Interior Walls 2x4 Marriage Walls Exterior Uponer Plumbing Connections Prairie Charcoal Lantern Light at Front Door 88” Window Headers Patina Lantern Light at Rear Door 90 MPH Exposure B Wind Load Two GFI-Protected Exterior Receptacles 20# Roof Load Design Vinyl Dutch Lap Siding Shutters on Front Door Side Insulation R-19 Fiberglass Insulation in Walls O.S.B. Sheathing R-31 Avg. Blown Insulation in Ceiling 7/12 Roof Pitch 12” Overhangs & Eaves Virginia Built Homes 10” Overhangs & Eaves - RAB Models R-19 Fiberglass Insulation in Wall Ridgevent Roof Ventilation System R-38 Avg. Blown Insulation in Ceiling 3/0 x 6/8 Fiberglass1/2 Lite Foam Gaskets at Switches & Prairie Grid Front Door w/ Dead Bolt Recepts on exterior Walls 3/0 x 6/8 Fiberglass 6-Panel Rear Door Insulated Hot Water Lines w/ Dead Bolt Plygem 62” Single Hung Low-E Windows w/ **Spacing for Framing Members may vary Prairie Grids Wind Wrap due to Design Requirements Vapor Barrier Architectural Shingles
SI-4
4/2017
Exteriors Standard Double 5” Shiplap
Vinyl Siding
Aspen White
Clay
Country Beige
Cypress
Driftwood
Pearl
Double 7” Insulated
Greystone
Double 4” Shiplap
Espresso
Rye- only Craneboard
Wheat- only Craneboard
Olive
*All siding colors come standard with white corner posts *Opt. DBL 7” insulated Craneboard siding is Available in all colors shown above
Regatta Blue
EX-1
4/2017
Exteriors Shake & Vertical Siding Shake Siding
Aspen White Shake
Black Walnut Shake
Clay Shake
Greystone
Vertical Batten Siding
Country Beige Vertical
Clay Vertical
Cypress Vertical
Driftwood Vertical
Greystone Vertical
Aspen White Vertical
EX-2
4/2017
Exteriors Shutters & Shingles 15� Raised Panel Shutter
Black
Brown
Blue
White
Green
Bordeaux
Board & Batten Shutters Available in all colors to left
Architectural Shingles
Teak
Williamsburg Gray
Onyx Black
Driftwood
Desert Tan
Chateau Green
EX-3
4/2017
Windows Kinro Info Facts Argon gas windows feature a sealed unit that is filled with gas between panes of glass to increase energy efficiency. Argon is an inexpensive, non-toxic, odorless gas that is used on residential windows to prevent frost from occurring at the bottom of window and at the same time will increase sound proofing characteristics of the window. Argon-filled windows are becoming an increasingly popular choice for many homeowners. Argon gas windows, energy star rated too, offer better insulation than natural windows because the gas is heavier than air. Low E Windows are not the same as argon gas windows, similar idea but different materials placed in between the panes. Argon Gas Windows Benefits Argon gas window can offer the following benefits: • • • • • • • • •
Minimizes heat exchange through the window Reduces the possibility of condensation and frost Can be used in all climates as the windows are sealed with the gas and it will not leak out. This type of windows can even block ultraviolet rays The additional cost of having argon gas windows will be recouped on a really short time Available in different commercial sizes depending on how they are going to be used Argon will not corrode the window material as Oxygen will do. Your heating and cooling systems will work more efficiently when you install argon gas windows Can be installed from floor to floor ceiling, shorter windows or open/close design
http://construction.about.com/od/Doors-And-Windows/a/Argon-Gas-Window-Benefits-Of-Argon-Filled-Windows.htm U-Factor Ratings for Windows by Nick Gromicko and Ethan Ward When quantifying the energy efficiency of a window assembly, the rate of loss of non-solar heat can be expressed as its U-factor (or U-value). Understanding the U-factors of windows is helpful for inspectors performing energy audits, as well as for consumers planning a new build or updating a house with energy-efficient windows. What is the U-Factor? The U-factor rating system was devised by the National Fenestration Rating Council (NFRC). The NFRC is a non-profit group that administers a uniform, independent rating and labeling system for the energy efficiency of building components, including windows, doors, skylights and attachment products. The U.S. Department of Energy and the Environmental Protection Agency’s Energy Star Program take the U-factor into account when evaluating the energy efficiency of windows for product certifications, and federal incentive and rebate programs. Windows that have the best resistance to heat flow and, thus, the best insulating qualities, have a low U-factor. Less efficient windows with poor insulating ability have a high U-factor. The combination of a window’s U-factor, air leakage, sunlight transmittance, and solar heat-gain coefficient add up to determine its level of energy efficiency.
WI-1
4/2017
Windows Kinro Argon Info cont. The temperature difference between the interior and exterior of a building creates the non-solar heat flow that results in windows losing heat to the outside during the winter, and gaining heat from outside during the summer. Compensating for this by cranking the thermostat or turning up the AC results in added energy needs and higher bills. Greater energy efficiency calls for a closer examination of the individual building components to see how they can work individually and in relation to each other in more effective ways. U-factor ratings can help in formulating standardized comparisons and objective evaluations. Determining the U-Factor The U-factor generally refers to the energy efficiency of the complete window assembly, which includes the glazing, window frame and spacer. The spacer is the component of a window frame that separates the glazing panels, and often reduces the U-factor at the glazing edges. The performance rating of the glazing alone, independent of the frame, is known as the center-of-glass U-factor, but use of this rating is less common. For most energy-efficient windows, the U-factor for the entire window assembly is higher than the U-factor at the center of the glass. The best, high-performance, double-pane windows may have a U-factor of 0.30 or lower, indicating that they are very energy-efficient. Manufacturers have started to incorporate low-emittance coatings and gas fills between panes in attempts to further decrease U-factors and provide an even more energy-efficient product. U-Factors in Different Climates While beneficial in cooling-dominated climates, a low U-factor is most important for windows in heating-dominated climates. The following are recommendations for the most effective window U-factors based on the major climate zones in the United States. • In colder climates in the North that are heating-dominated, the U-factor should be less than or equal to 0.30 for windows, and less than or equal to 0.55 for skylights. In areas where air-conditioning needs are minimal, windows that allow for solar heat gain during the day (a solar heat-gain coefficient of 0.40 or higher) can be considered energy-efficient with a U-factor as high as 0.32. Low U-factor windows are most important and will be most effective in this colder climate area where minimizing heat loss is critical to energy efficiency. • In mixed climates in the North and Midwest regions that use both heating and cooling, the U-factor should be less than or equal to 0.32 for windows, and less than or equal to 0.55 for skylights. Heating bills can help determine the importance of U-factors in this climate. Higher bills indicate the importance windows with a lower U-factor for added energy efficiency. • In mixed climates in the South and central regions that use both heating and cooling, the U-factor should be less than or equal to 0.35 for windows, and less than or equal to 0.57 for skylights. In these climates, again, heating costs can determine if a lower U-factor could be beneficial and more energy-efficient. If costs are high and a list of factors for heat loss is being addressed, window U-factor can be taken into consideration. A low U-factor for windows can also be helpful during hotter seasons when it is important to keep heat out, though a low solar heat-gain coefficient is more important in such situations.
WI-2
4/2017
Windows Kinro Argon Info cont. • In hot climates in the South that are cooling-dominated, the U-factor can be less than or equal to 0.60 for windows, and less than or equal to 0.70 for skylights. A lower U-factor is still useful during any cold times of the year when heating is needed in this climate. Such low ratings can ensure that heat is kept out on hot days when combined with a low solar heat-gain coefficient, which is the most important consideration in this climate.
From U-Factor Ratings for Windows - InterNACHI http://www.nachi.org/u-factor-windows.htm#ixzz2tKW0Bweq Spacers If you’ve lived in a cold climate, you’ve seen condensation and even frost on windows. When warm indoor air is cooled below its dew point, liquid water is squeezed from the air and condensation collects on the cold surface. Condensation typically develops around the edges of window glass. No surprise. The edge is where most double-paned glazing is held apart by aluminum spacers. Aluminum spacers are highly conductive, so the coldest part of a glazed unit is around its edges. Moist conditions support the growth of mold, decay and failure of finishes. Condensation affects durability and comfort. It is the number 1 reason for window-related callbacks. Warming the edges reduces the chance for condensation to form. It is virtually impossible to build a window that doesn’t have a thermal bridge. But the material and shape of the material used to make the spacer can substantially effect the rate that heat travels through a window’s edge. Many window makers now offer warm-edge spacers as standard fare. Conventional aluminum spacers are not acceptable! The best windows use less conductive materials like thin stainless steel, plastic, foam and rubber. Warm-edge spacers can improve the U-value of an entire window unit by 10%. But more importantly, condensation is reduced. These spacers boost the edge temperature by around 5 degrees. There are many trademarked versions like Swiggle Stick, Super Spacer, PPG Intercept, Ultra Edge, etc. What’s important is that the window you order has a warm-edge spacer system. And if you are concerned that the argon gas will leak out of the window, all indications are that a properly constructed seal will easily last 20 years. Check the warranty.
See more at: http://bct.eco.umass.edu/publications/by-title/windows-understanding-energy-efficient-performance/#sthash.v8E7Re1A.dpuf
WI-3
4/2017
Windows 9750 Single-Hung Window
9750 Single-Hung Window The 9750 provides premium thermal performance, keeping extreme hot and cold temperatures out of your home to protect your family and your utility bill. Its vinyl construction, dual weather seal and insulated NSHZZ WYV]PKL VW[PT\T Z[YLUN[O HUK LULYN` LɉJPLUJ`
Vinyl is virtually maintenance-free and never needs to be painted.
Fusion-welded construction provides a strong, weathertight seal.
Engineered balance system VɈLYZ ZTVV[O YLSPHISL VWLYH[PVU
Colonial brick mold lends H[[YHJ[P]L JSHZZPJ WYVÄSL 3/4" insulated glass with stainless steel spacer provides excellent energy performance; argon glass option available to further improve LULYN` LɉJPLUJ` Tilt-in bottom sash allows for easy cleaning from inside the home.
Waterdam meets HUD and residential requirements. Sweeplock securely locks window without binding. Hardware is located below the sightline and isn't visible from the exterior.
Dual weatherstripping provides an LULYN` LɉJPLU[ ^LH[OLY[PNO[ ZLHS
((4( HUK 5-9* *LY[PÄLK 7LYMVYTHUJL ,ULYN` :[HY 8\HSPÄLK CSA Listed and Canadian Approvals.
Multi-chambered frame and sash provide increased rigidity HUK LULYN` LɉJPLUJ`
2014 Kinro® Inc. All rights reserved. Kinro reserves the right to change any and all photos, pricing or information in this literature at any time. $OO .LQUR ZLQGRZ SURGXFWV DUH ODERUDWRU\ WHVWHG WR PHHW RU H[FHHG DOO PDQXIDFWXUHG KRXVLQJ IHGHUDO VSHFLÀFDWLRQV DV ODEHOHG RQ HDFK ZLQGRZ 3ULQWHG LQ WKH 8 6 $ ZZZ NLQUR FRP
WI-4
4/2017
Cabinets
KCMA Testing
KCMA Approved Evermore Cabinetry
- Overhead Cabinets Rated to 500 pound Capacity - Drawers Opened 28,000 Times with Weight - Cabinet Doors Opened 25,000 Times - Extreme Testing of Cabinet Finish
Java Maple Mission Flat Panel
Barnwood Oak Mission Flat Panel
Mocha Maple Glazed Raised Panel Evermore Custom Cabinets endure a series of rigorous test, measuring structural integrity. Cabinet doors, drawers and even the finish is tested before earning the KCMA Cabinet Certification.
Hickory Raised Panel
Chiffon Maple Glazed Mission Flat Panel
CA-1
4/2017
Cabinets Laminate Countertops
Black Alicante
Antique Cognac Pine
Bella Noche
Breccia
Cipollino Bianco
Italian White Di Pesco
Milano Quartz
Mill Antique Wood
Mocha Fantastico
Summer Carnival
Typoon Ice
Winter Carnival
CA-2
4/2017
Cabinets Optional Cultured Marble Bath Countertops
Aztec Granite
English Brown Granite
White
CA-3
4/2017
Cabinets
4” x 8” Tile - Marble Falls For Full Backsplash Only
Ceramic Tiles
4.25” x 12.75” Tile - Marbre Gray Pearl
Brune Highland Beige
Mosaic Tile - Gypsea Glass Not available with 3”x6” glass tile
White Waters
3” x 6” Glass Tile - Colorwave
Tritan
Suede Shoes
Galatea Smoked Pearl
CA-4
4/2017
this must be taken into account.
will give you constant high performance and will remain efficient for many years to
* Proper maintenance of the Range Hood will assure proper performance of the unit. * Disconnect the hood from the main supply before carrying out any maintenance work.
* This cooker hood can be used either in the Ducted Mode (ducting fumes to the
outside) or in the Recirculation Mode (internal recycling). The choice of
* Clean the hood using a damp cloth and a neutral liquid detergent. * DISPOSAL: Do not dispose this product as unsorted municipal waste. Collection of such waste separately for special treatment is necessary.
and servicing.
* Check that the mains voltage corresponds to the one indicated on the rating plate
fixed inside the hood.
KI-1 1
the open air in order to guarantee the entry of clean air.
prevent the backflow of exhaust gas. The kitchen must have an opening directly with
appliances), a sufficient degree of aeration must be guaranteed in the room in order to
* If the hood is used in conjunction with non-electrical appliances (e. g. gas burning
fireplaces, etc.)
* Do not connect the hood to exhaust ducts carrying combustion fumes (boilers,
2
* Do not disconnect the appliance with wet hands.
* Do not touch the light bulbs after appliance use.
* Do not check the status of the filters while the cooker hood is operating.
surface must be not less than 77cm.
*The minimum clearance distance between the range hood and the cooker hob
In certain circumstances electrical appliances may be a danger hazard.
WARNING!!
specified period of time.
* Only a qualified and trained service technician can undertake the work of installation
* Check that the domestic power supply guarantees adequate earthing.
* Clean and/or replace aluminum grease filters and activated charcoal filters after
be left to customers.
modes can
MAINTENANCE
Properly keep this instruction manual in a safe place for future reference.
* The hood should not be used by children or person not instructed in its correct use.
into flame.
* Deep fat fryer must be continuously monitored during use: overheated oil can burst
that it does not engulf the pan sides.
* Adjust the flame intensity to direct it onto the bottom of the pan only; making sure
* Never leave high naked flames under the hood when it is in operation.
* Never use the hood for purposes other than what it has been designed for.
fumes.
* The cooker hood has been designed only for domestic use to eliminate kitchen
USE
move this appliance. Failure to do so can cause physical injuries.
* Please read this instruction manual before installing and using this cooker hood.
improper installation.
INSTALLATION * The manufacturer will not be held liable for any damages resulting from incorrect or
RECOMMENDATIONS AND SUGGESTIONS
RECOMMENDATIONS AND SUGGESTIONS CHARACTERISTICS INSTALLATION & USE MAINTENANCE
CONTENTS
NOTICE: Considering excessive weight, two or more people are required to install or
to an electric hob. If the installation instructions for gas hobs specify a greater distance,
If you follow the recommendations contained in this Instruction Manual, our appliance
come.
* The minimum distance is 770mm from the cooker hood to a gas hob, and is 650mm
Dear Customer,
Kitchen
Stainless Steel/Glass Chimney Style Range Hood
4/2017
2pcs
10.a 10.b
CHARACTERISTICS
3
5/7pcs
9
fumes from appliances burning gas or other fuels.
DIMENSIONS
1pc
8
3pcs 5/7pcs 2pcs 1pc
Q’ty 1pc
10.c 11 12 13
Ref 13
1pc
1set
7.2
* The discharge air must not be discharged into a flue which is used for exhausting
6
* Do not flambé under the range hood.
1pc 1or2pcs
5
1pc
1pc
4
Q’ty
1pc
3
7.1
1pc
2.2
Ref
1pc
* There is a fire risk if cleaning is not carried out in accordance with instructions.
1set
2.1
1pc
Q’ty
2
1
Ref
COMPONENTS
same time as appliances burning gas or other fuels.
* There shall be adequate ventilation of the room when the range hood is used at the
do not play with the appliance.
person responsible for their safety. Children should be supervised to ensure that they
they have been given supervision or instruction concerning use of the appliance by a
physical, sensory or mental capabilities, or lack of experience and knowledge, unless
* This appliance is not intended for use by persons (including children) with reduced
* Don’t use this product outdoor.
appliance only under supervision of adults and out of the reach from children.
* Children don’t recognize the risks of electrical appliances. Therefore use or keep the
* Disconnect the electrical plug prior to any maintenance.
hazard.
* Constantly check food frying to avoid that the overheated oil may become a fire
* Avoid free flame, as it is damaging for the filters and a fire hazard.
4
Instruction Manual
Documentations
Fixing Ring
2 rings for Glass Fixing Screws(D4.2mm)
Drywall Anchors
Chimney Bottom Fixing Screws (ST 4 X8 MM)
Chimney Mounting Bracket Screws (M 4 X 10 MM)
Mounting Screws (ST 5 X 50MM)
Oil Cup
Damper (flaps)
Hood Mounting Bracket
Chimney Mounting Bracket
Installation Components
Cassette filter
Charcoal Filter(optional)
Glass
Plastic Exhaust Duct or Aluminum Exhaust Duct (optional)
Decorative Chimney Bottom
Decorative Chimney Top (optional)
Telescopic Chimney comprising
outlet adapter
Hood body, complete with: controls, lights, blower, filters, air
Product Components
Kitchen
Stainless Steel/Glass Chimney Style Range Hood
KI-2
4/2017
Mark two holes on the wall as shown 220mm below the hood mounting bracket
7.
2.
1.
KI-3
6
hood until it securely engages the bracket.
the hood mounting bracket. Gently lower the
Balance the hood body by slightly adjusting
bracket 7.2 as shown.
Hook the body onto the hood mounting
MOUNTING THE HOOD BODY
Fix the two brackets using the mounting screws and drywall anchors.
9.
10mm holes at all the centre points marked.
Drill
8.
holes for fixing the hoods body.
Mark the wall at the centre of the holes in the bracket.
notches to the vertical reference line.
Place the hood mounting bracket 6.2 on the wall as shown aligning the central
the bracket.
Mark the wall at the centre of the holes in
(notch) with the vertical reference line.
ceiling or upper limit aligning the centre
the wall as shown about 20mm from the
Place chimney mounting brackets 6.1 on
electric hob or 750mm above the gas hob.
Draw a horizontal line at 650mm above the
be installed.
6.
5.
4.
3.
2.
the centre of the area in which the hood will
up to the ceiling, or as high as practical, at
)
At least two people will be required to mount the hood.
WALL DRILLING AND BRACKETS FIXING (X=Y1. Draw a vertical line on the supporting wall
Note 2:
exterior surfaces of the hood and chimney prior to final installation.
Note 1 : On stainless steel hoods, carefully remove the plastic protective film from all
INSTALLATION & USE
Kitchen
Stainless Steel/Glass Chimney Style Range Hood
4/2017
outlet adapter, it should be flexible in opening and closing.
To be sure that the damper (flaps) is locked well on the air
150mm round duct into
make sure the duct is fixed well on.
using the fixing ring. Adjust the bolt of the fixing ring to
Secure the duct connected with the air outlet adapter by
the recessed area of the air outlet adapter.
Attach an adequate length of
150mm round duct
sides of the decorative chimney top.
Please note that the air will flow out from the two grids on the
Install the charcoal filter on.
to the air outlet adapter.
ducting. Attach an adequate length of
Determine the length of the compressed flexible aluminum
KI-4 7
The air must not be discharge into a flue that is used for exhausting fumes from
5.
150mm round duct to the air outlet adapter.
Attach an adequate length of
longer duct runs.
of them as possible. Larger ducting may be required for best performance with
reduce the performance of the hood. Use as few
Long duct runs, elbows, and transitions will
4.
3.
perform most efficiently.
1.
8
outside the decorative chimney top 2.1. Carefully place
Carefully slide the decorative chimney bottom 2.2 down
Decorative Chimney Bottom
sides.
the two chimney bracket screws 10.b supplied from two
chimney mounting bracket that is well fixed on the wall with
chimney bottom 2.2. Secure decorative chimney top 2.1 to the
Raise the decorative chimney top 2.1 up inside the decorative
A straight, short duct run will allow the hood to
hood and the outside.
2.
TELESCOPIC CHIMNEY COMPRISING ASSEMBLY Decorative Chimney Top
Decide where the ductwork will run between the
1.
* The earthing of this hood is compulsory. Do not remove ground prong of the plug.
the hood.
* Do not use the plug and an extension cord other than the ones initially supplied with
agent or similarly qualified persons in order to avoid a hazard.
* If the supply cord is damaged, it must be replaced by the manufacturer, its service
before wiring.
applicable codes and standards. Turn off electrical power at service entrance
* Electrical wiring must be done by a qualified person(s) in accordance with all
Electrical Connection
3.
2.
1.
is preferred.
Caution: To reduce the risk of fire, use metal ductwork
CONNECTIONS Ducted mode air exhaust system
2.
1.
Caution: To reduce the risk of fire, use metal ductwork only.
DUCT FIXING
2.
DAMPER (FLAPS) FIXING 1. Fix the damper (flaps) into the air outlet adapter.
the body.
Recirculation Mode Caution: Do not use plastic or rigid metal ducting.
ductwork sections.
rings for Glass Fixing Screws(D4.2mm)
glass fixing screws from inside of body.
back towards hood location. Use duct tape to seal the joints between
6. Install a roof/wall cap. Connect round metal ductwork to cap and work
Fix the glass 4. on the top frame with 12. 2
2. To be sure that the glass is fixed well on
1.
GLASS FIXING
appliances burning gas or other fuels" "Regulations concerning the discharge of air have to be fulfilled.
Kitchen
Stainless Steel/Glass Chimney Style Range Hood
4/2017
Bottom screws 10.c supplied from inside of hood body.
Fix the Decorative Chimney Bottom 2.2 with the three decorative Chimney
the decorative chimney bottom 2.2 into the recessed area of the hood body top.
SPECIFICATIONS
4 – LIGHT
3 - HIGH SPEED
2 - MEDIUM SPEED
1 - LOW SPEED
0 - OFF
9
The blower switch turns the blower on to three speed settings:
The light switch turns the lamps on and off.
The hood is operated using the push button on the front panel.
OPERATION OF CONTROLS
2.
Remove the grease filter one by one by
engaged after assembly.
latch, push filter into position and release. Make sure the filter is securely
To install the grease filter, align rear filter tabs with slots in the hood. Pull out the
handle is visible from the outside.
When refitting the filters, make sure that the
Allow them to be dry before refitting.
Wash the filters, taking care not to bend them.
and remove.
filter from the hood. Tilt the filter downward
pulling out each latch. This will disengage the
To install the charcoal filter, and lock it until the stop click is heard.
on the appliance. 10
WARNING: Always switch off the electrical supply before carrying out any operation
Base)
This range hood may require two halogen bulbs (Type JCD, 12V, 20W Max, G-4
HALOGEN BULBS
installed.
2. Install grease filter after charcoal filter is
1.
frequently in the case of heavy usage.
approximately every 3 months of operation, or more
NON-DUCTED RECIRCULATION CHARCOAL FILTER This filter is not washable, can not be regenerated, and should be replaced
4.
3.
2.
1.
* Grease filters are washable.
more frequently for heavy use). Use a warm detergent solution.
GREASE FILTER * The grease filters should be cleaned frequently (every two months of operation, or
MAINTENANCE
Kitchen
Stainless Steel/Glass Chimney Style Range Hood
KI-5
4/2017
BULBS MAY BE HOT. TAKE CARE WHEN TAKING THE REPLACEMENT.
CARE WHEN TAKING THE REPLACEMENT.
THE SURFACE, THE COVER OF THE HALOGEN BULBS MAY BE HOT. TAKE
11
Replace with Type E14, 15W Max normal bulb. Do not touch replacement bulb
2.
with bare hands !
Kick off the normal bulbs by hand.
1.
To change bulbs:
on the appliance.
WARNING: Always switch off the electrical supply before carrying out any operation
This range hood may require two normal bulbs (Type E14, 15W Max).
NORMAL BULBS
2.
1.
CAUTION:
Allow it to be dry before refitting.
detergent solution.
not be more than half. Use a warm
The oil accumulated inside the oil cup can
The oil cup should be cleaned frequently.
motor blower.
12
* Painted surfaces should be cleaned with warm water and mild detergent only.
with a clean cloth.
contain chemicals that may be harmful. Rinse with water after exposure and wipe dry
remain in contact with stainless steel for extended periods. Many of these compounds
* Do not allow salt solutions, disinfectants, bleaches, or cleaning compounds to
surface causing rust.
* Do not use ordinary steel wool or steel brushes. Small bits of steel may adhere to the
* Do not allow deposits to remain for long periods of time.
finish. Avoid using too much pressure that may mar the surface.
cleanser and water. Rub lightly in direction of polishing lines or “ grain” of the stainless
* For stubborn cases use a plastic scouring pad or soft bristle brush together with
or stainless steel polishing powder with a little water and a soft cloth.
* For discolorations or deposits that persist, use a non-scratching household cleanser
avoid water marks.
* Follow all cleaning by rinsing with clear water. Wipe dry with a clean, soft cloth to
* Hot water with soap or detergent is all that is usually needed.
Cleaning tips:
preserve its fine appearance.
HOOD CLEANING Stainless steel is one of the easiest materials to keep clean. Occasional care will help
3.
2.
To install the oil cup, and lock it on to the
OIL CUP 1.
Replace with Type JCD, 12V, 20W Max, G-4 Base halogen bulb. Do not touch
replacement bulb with bare hands !
3.
BULBS MAY BE HOT. TAKE CARE WHEN TAKING THE REPLACEMENT.
by using the flat screw driver.
Kick off the halogen bulb cover
Remove the bulb by pulling sidewards (DO NOT ROTATE).
1.
2.
CAUTION:
To change bulbs:
Kitchen
Stainless Steel/Glass Chimney Style Range Hood
KI-6
4/2017
Bathrooms Square White Porcelain Lav Sink
BA-1
4/2017
Bathrooms 24� Stainless Steel Grab Bar for Tile Shower PFGB18SF
Stainless Steel Grab Bar Product Features Product Features
t w 44 HSBC CBS X DPODFBMFE GMBOHF .t #BS HBVHF TUBJOMFTT TUFFM 1-1/2� SS grab bar w/concealed flange .t 'MBOHF HBVHF TUBJOMFTT TUFFM Bar - 18 gauge (.048) 304 stainless steel .t 4DSFXT Y w TFMG UBQQJOH TUBJOMFTT TUFFM Flange - 14 gauge 304 stainless steel .t 'JOJTI TBUJO GJOJTI PO SFHVMBS HSBC CBST 4'
Screws - #10 x 2� self tapping stainless steel . Finish - satin finish on regular grab bars (SF) QFFOFE GJOJTI PO QFFOFE HSBC CBST 1'
peened finish on peened grab bars (PF) t 3BUFE UP MC UFTU MPBE . Rated to 250 lb. test load
PFGB18SF Satin Finish
Peened Finish
A
B
C
PFGB12SF
PFGB12PF
12�
9�
15�
PFGB16SF
PFGB16PF
16�
13�
19�
PFGB18SF
PFGB18PF
18�
15�
21�
PFGB24SF
PFGB24PF
24�
21�
27�
PFGB30SF
PFGB30PF
30�
27�
33�
PFGB32SF
PFGB32PF
32�
29�
35�
PFGB36SF
PFGB36PF
36�
33�
39�
PFGB42SF
PFGB42PF
42�
39�
45�
PFGB48SF
PFGB48PF
48�
45�
51�
Product Specifications
1-1/2� 1-1/2� (38.1mm) (38.1mm)
Note: Stainless steel handlebar MUST BE attached to wall stud.
Warranty Warrantyand andCodes Codes
/8�
7
This warranty. This PROFLO PROFLOproduct productcarries carriesa a1-year 1-yearlimited limited warranty . 3� 3� (76mm) Š 2013 Ferguson Enterprises, Inc. All Rights Reserved
Distributed Exclusively by Ferguson and Wolseley Canada
1-1/2� (38.1mm)
3� 1-1/2� (38.1mm)
17482 09/13
BA-2
4/2017
Bathrooms Standard Elongated Toilet PFGB18SF
Stainless Steel Grab Bar Product Features Product Features
t w 44 HSBC CBS X DPODFBMFE GMBOHF .t #BS HBVHF TUBJOMFTT TUFFM 1-1/2� SS grab bar w/concealed flange .t 'MBOHF HBVHF TUBJOMFTT TUFFM Bar - 18 gauge (.048) 304 stainless steel .t 4DSFXT Y w TFMG UBQQJOH TUBJOMFTT TUFFM Flange - 14 gauge 304 stainless steel .t 'JOJTI TBUJO GJOJTI PO SFHVMBS HSBC CBST 4'
Screws - #10 x 2� self tapping stainless steel . Finish - satin finish on regular grab bars (SF) QFFOFE GJOJTI PO QFFOFE HSBC CBST 1'
peened finish on peened grab bars (PF) t 3BUFE UP MC UFTU MPBE . Rated to 250 lb. test load
PFGB18SF Satin Finish
Peened Finish
A
B
C
PFGB12SF
PFGB12PF
12�
9�
15�
PFGB16SF
PFGB16PF
16�
13�
19�
PFGB18SF
PFGB18PF
18�
15�
21�
PFGB24SF
PFGB24PF
24�
21�
27�
PFGB30SF
PFGB30PF
30�
27�
33�
PFGB32SF
PFGB32PF
32�
29�
35�
PFGB36SF
PFGB36PF
36�
33�
39�
PFGB42SF
PFGB42PF
42�
39�
45�
PFGB48SF
PFGB48PF
48�
45�
51�
Product Specifications
1-1/2� 1-1/2� (38.1mm) (38.1mm)
Note: Stainless steel handlebar MUST BE attached to wall stud.
Warranty Warrantyand andCodes Codes
/8�
7
This warranty. This PROFLO PROFLOproduct productcarries carriesa a1-year 1-yearlimited limited warranty . 3� 3� (76mm)
1-1/2� (38.1mm)
3� 1-1/2� (38.1mm)
BA-3
4/2017
Tubs and Showers 10” x 14” Ceramic Tile With Accent combinations
Ceramic Tile for Showers
Tritan Skybridge Gray
Skybridge Off White
Galatea
7” x 20” Ceramic Tile With Accent combination
Emblem Gray
Lucente Grazia TS-1
4/2017
Tubs and Showers 54� Ceramic Shower Tile Layout 10x14 Ceramic Tile (with Ribbon)
TS-2
4/2017
Tubs and Showers 48� 2-Sided Glass Ceramic Shower Tile Layout 7x20 Ceramic Tile (with Ribbon)
TS-3
4/2017
Tubs and Showers 4’x6’ Walk-In Shower Ceramic Shower Tile Layout 10x14 Ceramic Tile (with Ribbon)
TS-4
4/2017
Tubs and Showers 4’x6’ Walk-In Shower Ceramic Shower Tile Layout 7x20 Ceramic Tile (with Ribbon)
TS-5
4/2017
Tubs and Showers 4’x6’ Walk-In Shower Ceramic Shower Tile Layout 7x20 Ceramic Tile (with Ribbon)
TS-6
4/2017
Tubs and Showers 48” Fiberglass Shower 1" [25mm]
Acrylic Towel Bar * Not included on * MP version of this product. Model number becomes MP5843X
321" [89mm]
78" [1981mm]
4912" [1257mm] 2321" [597mm]
312" [88mm]
4" [102mm]
812" [216mm]
ELEVATION
24" [610mm]
SECTION "A-A"
12" [305mm]
PRODUCT SPECIFICATIONS:
15" [381mm] 36" [914mm]
* * * * *
Ø383" Drain [Ø86mm] 312" [89mm]
* * *
48" [1219mm]
*
PLAN 48" [1219mm] Shower w/ 8 1/2" [216mm] Threshold, Molded Soap Ledges, & Molded Seats
* * *
Product complies with NAHB, HUD UM-73A, and ANSI-Z124.1.2. Product has a Class B fire rating as determined by ASTM E-84 test method. Reinforced & slip resistant floor. Integral 1" [25mm] nailing flange. 1" [25mm] acrylic towel bar (not included on the MP version of this product. Model number becomes MP5843X.) Molded soap ledges Two molded seats approx. 7"W x 16"D x 18"H Door Opening: W-44 1/2" [1130mm] H-68" [1727mm] Accepts Clarion Model RE948 cap (adds 8 1/2" [216mm] to the overall height of the unit. All dimensions +/- 1/4" [6.4mm] Clarion Bathware reserves the right to change design and/or dimensions. Dimensions are the same for RE, MP, and all other versions of this model.
CENTER DRAIN
5848XT 48" [1219mm] Shower w/ 8 1/2" [216mm] Threshold, Molded Soap Ledges, Molded Seats, & Center Drain
TS-7
4/2017
Tubs and Showers 54” Fiberglass Shower 1" [25mm]
Molded Soap Ledges 3" [76mm]
7714" [1962mm]
Molded Seats
53" [1346mm]
2112" [546mm]
312" [89mm]
812" [216mm]
ELEVATION
314" [83mm]
SECTION "A-A"
1341" [333mm]
27" [685mm] 1612" [416mm] 3543" [908mm]
Ø383" Drain [Ø86mm]
PRODUCT SPECIFICATIONS: 54" [1372mm]
PLAN 54" [1372mm] Shower w/ 8 1/2" [216mm] Threshold, Molded Soap Ledges, & Molded Seats CENTER DRAIN
* * * * * * * *
Product complies with NAHB, HUD UM-73A, and ANSI-Z124.1.2. Product has a Class B fire rating as determined by ASTM E-84 test method. Reinforced & slip resistant floor. Integral 1" [25mm] nailing flange. Sufficient drain clearance to accommodate above the floor plumbing. Molded soap ledges. Two molded seats approx. 13"W x 18"D x 16"H Door Opening: W-49 1/2" [1257mm] H-67" [1702mm] * All dimensions +/- 1/4" [6.4mm] * Clarion Bathware reserves the right to change design and/or dimensions. * Dimensions are the same for RE, MP, and all other versions of this model.
5854X 54" [1372mm] Shower w/ 8 1/2" [216mm] Thresholds, Molded Soap Ledges, Molded Seats, & Center Drain
TS-8
4/2017
Tubs and Showers 60” Fiberglass Tub-Shower 1" [25mm]
Molded Soap Ledges 3" [76mm]
7714" [1962mm]
1214" [311mm]
Molded Seats
5314" [1353mm]
812" [216mm]
21" [533mm]
ELEVATION
312" [89mm] 4" [102mm]
SECTION "A-A"
30" [762mm]
16" [406mm] 3543" [908mm]
Ø383" Drain [Ø86mm]
PRODUCT SPECIFICATIONS:
60" [1524mm]
PLAN 60" [1524mm] Shower w/ 8 1/2" [216mm] Threshold, Molded Soap Ledges, & Molded Seats CENTER DRAIN
* * * * * * *
Product complies with NAHB, HUD UM-73A, and ANSI-Z124.1.2. Product has a Class B fire rating as determined by ASTM E-84 test method. Reinforced & slip resistant floor. Integral 1" [25mm] nailing flange. Molded soap ledges. Two molded seats approx. 11"W x 19"D x 15"H Door Opening: W-55 3/8" [1406mm] H-67 1/4" [1708mm] * All dimensions +/- 1/4" [6.4mm] * Clarion Bathware reserves the right to change design and/or dimensions. * Dimensions are the same for RE, MP, and all other versions of this model.
5860X 60" [1524mm] Shower w/ 8 1/2" [216mm] Threshold, Molded Soap Ledges, Molded Seats, & Center Drain TS-9
4/2017
Tubs and Showers 60� Fiberglass Garden Tub with Curved Front
TS-10
4/2017
Tubs and Showers 60� Fiberglass with Curved Front and Whirlpool Jets
TS-11
4/2017
Tubs and Showers 60� Fiberglass Garden Tub with Curved Front & Full Surround
TS-12
4/2017
Tubs and Showers 60� Fiberglass Garden Tub with Curved Front, Full Surround & Whirlpool Jets
TS-13
4/2017
Tubs and Showers 48” x 35” Shower Pan for Tile Shower
TS-14
4/2017
Tubs and Showers 54” x 35” Shower Pan for Tile Shower
TS-15
4/2017
Tubs and Showers 60” x 35” Shower Pan for Tile Shower
TS-16
4/2017
Tubs and Showers 49” x 49” Corner Fiberglass Shower 1" [25mm]
7843" [2000mm]
52" [1321mm]
23" [584mm] 9" [229mm]
812" 21" [216mm] [533mm]
21" [533mm]
49" [1245mm]
49" [1245mm] Molded Shelving
Molded Shelving
Molded Seat
Ø383" Drain [86mm]
112" Nailing Flange [38.1mm]
PRODUCT SPECIFICATIONS:
Molded Shelving Molded Seat
24" [610mm]
5" [127mm]
1112" [294mm]
6" [151mm]
34" [876mm] 4" [98mm]
24" [610mm] 90°
37" [932mm]
PLAN 49" [1245mm] Corner Shower w/ Molded Seats & Molded Shelving
Dam of Shower
Post of Shower
11" 143" 4
* * * * * * *
Product complies with NAHB, HUD UM-73A, and ANSI-Z124.1.2. Product has a Class B fire rating as determined by ASTM E-84 test method. Reinforced & slip resistant floor. Integral 1" [25mm] nailing flange. Molded shelving Two molded seats approx. 11"W x 19"D x 16 1/2"H Door Opening: W-34" [864mm] H-68 1/2" [1740mm] * All dimensions +/- 1/4" [6.4mm] * Clarion Bathware reserves the right to change design and/or dimensions. * Dimensions are the same for RE, MP, and all other versions of this model.
Top Flanges of Shower
CENTER DRAIN
4924X 49" [1245mm] Corner Shower w/ 9" [229mm] Threshold Molded Seats, Molded Shelving, & Center Drain TS-17
4/2017
Tubs and Showers 4’ x 6’ Shower Pan for Tile Shower LQ > PP@
LQ > PP@
6(&7,21 % % LQ
(/(9$7,21
LQ > PP@ “ > PP@
> PP@
LQ > PP@ LQ > PP@
LQ > PP@
%
LQ > PP@
352'8&7 63(&,),&$7,21 3URGXFW FRPSOLHV ZLWK 1$+% +8' 80 $ DQG 1$6, =
3URGXFW KDV D &ODVV % ILUH UDWLQJ DV GHWHUPLQHG E\ $670 ( WHVW PHWKRG 5HLQIRUFHG VOLS UHVLVWDQW IORRU ,QWHJUDO > PP@ QDLOLQJ IODQJH $OO GLPHQVLRQV > PP@ XQOHVV QRWHG RWKHUZLVH &ODULRQ %DWKZDUH UHVHUYHV WKH ULJKW WR FKDQJH GHVLJQ DQG RU GLPHQVLRQV
% 3/$1 > PP@ [ > PP@ 6KRZHU 3DQ 7LOLQJ )ODQJHV 1R 7KUHVKROG
(1' '5$,1
63 17
> PP@ [ > PP@ 6KRZHU 3DQ Z 7LOLQJ )ODQJH $OO 6LGHV 1R 7KUHVKROG
TS-18
4/2017
Tubs and Showers 4’ x 8’ Shower Pan with Seat for Tile Shower
TS-19
4/2017
Tubs and Showers
17"
16"
151 4"
17"
16"
20” x 20” Fiberglass Corner Seat for Tile Showers
3"
ELEVATION SECTION C-C C
181 4"
21 "
" 21 6"
6"
C 193 4"
PLAN
352'8&7 63(&,),&$7,21 6SHFLDO LQVWDOODWLRQ LQVWUXFWLRQ IRU WKLV XQLW PXVW EH IROORZHG FDUHIXOO\ 3URGXFW FRPSOLHV ZLWK 1$+% +8' 80 $ $16, = 3URGXFW KDV D &ODVV % ILUH UDWLQJ DV GHWHUPLQHG E\ $670 ( WHVW PHWKRG 5HLQIRUFHG VOLS UHVLVWDQW VHDW 0ROGHG VHDW ,QWHJUDO > PP@ QDLOLQJ IODQJH $OO GLPHQVLRQV > PP@ &ODULRQ %DWKZDUH UHVHUYHV WKH ULJKW WR FKDQJH GHVLJQ DQG RU GLPHQVLRQV 'LPHQVLRQV DUH WKH VDPH IRU 5( 03 DQG DOO RWKHU YHUVLRQV RI WKLV PRGHO
63&6
0ROGHG 6KRZHU 6HDW IRU 6KRZHU 3DQV
TS-20
4/2017
Tubs and Showers 60” x 48” Fiberglass Shower with Seat
TS-21
4/2017
Tubs and Showers Roman Soaker Drop in Tub
TS-22
4/2017
Tubs and Showers Roman Soaker Drop in Tub with Jets
TS-23
4/2017
Tubs and Showers 72� Lincoln Soaker Tub Drop In
TS-24
4/2017
Tubs and Showers 72� Lincoln Soaker Tub Drop in with Jets
TS-25
4/2017
Tubs and Showers 60� Roll-in Shower with Seat, Grab Bars & Etc.
TS-26
4/2017
Tubs and Showers 48” x 46” Tile Imprint Fiberglass Shower with 2 Seats 1" [25mm]
Acrylic Towel Bar * Not included on * MP version of this product. Model number becomes MP5843X
321" [89mm]
78" [1981mm]
4912" [1257mm] 2321" [597mm]
312" [88mm]
4" [102mm]
812" [216mm]
ELEVATION
24" [610mm]
SECTION "A-A"
12" [305mm]
PRODUCT SPECIFICATIONS:
15" [381mm] 36" [914mm]
* * * * *
Ø383" Drain [Ø86mm] 312" [89mm]
* * *
48" [1219mm]
*
PLAN 48" [1219mm] Shower w/ 8 1/2" [216mm] Threshold, Molded Soap Ledges, & Molded Seats
* * *
Product complies with NAHB, HUD UM-73A, and ANSI-Z124.1.2. Product has a Class B fire rating as determined by ASTM E-84 test method. Reinforced & slip resistant floor. Integral 1" [25mm] nailing flange. 1" [25mm] acrylic towel bar (not included on the MP version of this product. Model number becomes MP5843X.) Molded soap ledges Two molded seats approx. 7"W x 16"D x 18"H Door Opening: W-44 1/2" [1130mm] H-68" [1727mm] Accepts Clarion Model RE948 cap (adds 8 1/2" [216mm] to the overall height of the unit. All dimensions +/- 1/4" [6.4mm] Clarion Bathware reserves the right to change design and/or dimensions. Dimensions are the same for RE, MP, and all other versions of this model.
CENTER DRAIN
5848XT 48" [1219mm] Shower w/ 8 1/2" [216mm] Threshold, Molded Soap Ledges, Molded Seats, & Center Drain TS-27
4/2017
Faucets Clarion Bathware Warranty ͳǥ ʹͲͳ͸
Clarion Bathware offers the following limited warranties against defects in material and workmanship. These warranties apply only to the original owner/end-user and are non-transferrable.
Residential use: Merchandise is guaranteed for a period of six (6) years from the date of initial purchase against defects in material and workmanship.
Commercial use: Merchandise is guaranteed for a period of six (6) years from the date of initial purchase against defects in material and workmanship.
Component/Accessories: Merchandise supplied by Clarion Bathware is guaranteed for a period of one (1) year from the date of initial purchase against defects in material and workmanship. All claims must include proof of purchase. If within the warranty period any such product shall prove to be defective of material defects, manufacturing defects, labor defects, it shall be repaired or replaced (with a product of equal value) excluding removal and installation at the manufacturer’s option. Shipping Damages: All units must be carefully inspected upon delivery. Any damage must be reported on the receipt or freight slip at that time. When applying the warranty, adequate time must be permitted to schedule and complete the work. Inspections and work will be scheduled and completed by an authorized representative of Clarion Bathware. Clarion Bathware will not be responsible for any claims related to failures, damages, delays or excessive costs incurred that could have been discovered, avoided or repaired with proper inspection and testing prior to or during installation. EXCLUSIONS: 1. This warranty shall not apply to incorrect operating procedures, breakage or damages caused by normal wear and tear, improper storage, fault, carelessness, negligence, abuse, misuse, use other than intended (non-bathing), misapplication, improper maintenance, alteration, or modification of the unit by or for the buyer, as well as chemical or natural corrosion, fire, act of god, or any other casualty. 2. The original owner/end-user covered by the present warranty is entirely responsible for its proper installation and for all plumbing and electrical connections. Clarion Bathware neither installs nor supervises or contracts for the installation and consequently cannot be held responsible for it. 3. This warranty does not apply to units or equipment not installed and connected in accordance with manufacturer’s instructions and in conformity with all local, state, codes for such installations. 4. CLARION BATHWARE IS NOT LIABLE FOR PERSONAL INJURY OR DEATH TO ANY PERSON, INCIDENTAL OR CONSEQUENTIAL DAMAGE, LOSS OF TIME OR PROFITS, INCONVENIENCE, INCIDENTAL EXPENSES, LABOR OR MATERIAL CHARGES OR ANY OTHER COSTS RELATED TO THE APPLICATION OF THE PRESENT WARRANTY OR IN CONNECTION WITH ANY COSTS RELATED TO THE REMOVAL OR REPLACEMENT OF EQUIPMENT OR TUB. AT NO TIME WILL CLARION BATHWARE BE LIABLE FOR ANY AMOUNT IN EXCESS OF THE PURCHASE PRICE OF THE UNIT IN QUESTION. 5. This warranty does not apply to the staining or malfunction of the unit due to ferrous, hard or salty water. Nor does the warranty cover fading, blistering or cracking due to excessive wear, light exposure or cleaning methods. 6. The owner/end-user will be responsible for all expenses incurred to supply access for service of the unit and its components. 7. The warranty will be voided if the unit is moved from the original installation location. 8. Any Third-party alterations or installations will not be covered under this warranty. 9. All Clarion Bathware modules have slip-resistant textured floors. The use of “suction-cup� bathmats can cause surface damage and will not be covered under warranty. 10. Clarion Bathware makes no express warranty, No warranty of merchantability. No warranty of fitness for particular purposes, compliance with any code, neither any other warranty implied or statutory for its products other than specified above. 11. Any refusal to permit the repair or replacement (at Clarion Bathware’s discretion) of the unit will terminate the warranty and any associated claims. Any repaired unit or replacement will remain under warranty for the duration of the original warranty period only. 12. Any repair not authorized by Clarion Bathware will not be covered under the warranty.
Clarion Bathware reserves the right to change the warranty at any time, with the understanding that any such change shall not supersede the terms of the warranty implied at the purchase date of the unit in question. FA-1
4/2017
Faucets Clarion Bathware Care and Maintenance
44 Amsler Avenue Shippenville, PA 16254 Phone (800) 576-9228 Fax (814) 226-5568 CARE AND MAINTENANCE DO NOT USE ABRASIVE CLEANERS Abrasive cleaners may scratch and dull the surface of the unit. To clean the unit after installation, use warm water and one of the stronger liquid detergents, such as; Top Job, Liquid Ajax, or Mr. Clean. Use these liquid detergents for normal day-to-day cleaning. Plaster can be removed with a nylon or polypropylene scrubber. DO NOT USE steel wool, metal scraper, wire brushes, or other metal tools. One of the powder type detergents, such as Spic & Span, may be used on a damp cloth to provide mild abrasive action to remove residue plaster. Minor stains can be removed with a household strength ammonia or bleach. A periodic scrub down with gel gloss or a dishwashing detergent (wear rubber gloves) will usually remove any soap or mineral deposits. Periodic waxing with an automotive polish followed by a light application of liquid wax, such as Johnson’s’ Jubilee will add luster and preserve the finish. Lighted smoking materials will leave burn marks on fiberglass products. This or other similar damages can often be repaired by rubbing the affected area with an automotive type body polishing compound, such as; Dupont No. 7 followed by an automotive body wax, such as Simoniz. More severe burns require careful sanding with 400 – 600 grit wet carborundum sandpaper and a final rub out with the automotive polishing compound and wax. Extensive damage can be completely repaired. A professional service repairman in your area should perform such repair work. If local service is not available, or if you need further assistance, contact Clarion Bathware. Repair kits with gelcoat included, may be purchased through Clarion Bathware. Whirlpool Cleaning Whirlpool systems should be cleaned periodically using household bleach. Always use caution when using chlorine based products in conjunction with other cleaning products. The possibility of harmful fumes could result. Always rinse well. Fill tub with warm water above jets and add 1 cup of household bleach. Turn system on for 5 minutes. Drain tub and re-fill with cold water. Restart system for 10 minutes then drain. FA-2
4/2017
Faucets Huntington Brass Tub/Shower Trim Specification Break Down SPECIFICATION / BREAK DOWN P6361201, P6361202, P6361203 - Tub and Shower Trim Description
5 Setting shower head P Compliant
Standards I O ADA Acce b l ty Gu el ne for ul an Fac l t e - 4.27.4 Control an Me CALGr compliant
c
P6361201
Colors / Finishes P6361201 - Chrome P6361202 - PVD Satin Nickel P6361203 - Antique Bronze
BREAK DOWN Component Parts List
Note: Summit Series ONLY
FA-3
4/2017
Faucets Huntington Brass Tub/Shower Trim Specification Break Down
1” 7_ 4
1” 2_ 2
5”
1” 7_ 2 1” 3_ 2
1”
6”
Note: Summit Series ONLY
FA-4
4/2017
Faucets Huntington Brass Sherington 4” Center Set Trim Specification Break Down SPECIFICATION / BREAK DOWN W4461201-1, W4461202-1, W4461203-1 - Sherington 4” Center Set Description t Degree turn ceramic disc cartridges
Standards I
O
F ADA Acce b l ty Gu el ne for ul an Fac l t e - 4.27.4 Control an Me
c
W4461201-1
Colors / Finishes W4461201-1 - Chrome W4461202-1 - PVD Satin Nickel W4461203-1 - Antique Bronze
BREAK DOWN Component Parts List
Note: Summit Series ONLY
FA-5
4/2017
Faucets Huntington Brass Sherington 4” Center Set Trim Specification Break Down
1” 9_ 2 1” 5_ 2
1” 3_ 2
_ MAX 1 1” 2
4”
4”
3” 8
6_
1/2-14NPSM
_ 6 1” 2
Item Number
W4461201-1, W4461202-1, W4461203-1
Note: Summit Series ONLY
Type
Date
3-24-2016
FA-6
4/2017
Faucets Huntington Brass Roman Tub Fill Trim Specification Break Down SPECIFICATION / BREAK DOWN S7361201, S7361202, S7362103 - Roman Tub Filler Description
Standards I O ADA Acce b l ty Gu el ne for ul an Fac l t e - 4.27.4 Control an Me
c
S7361201
Colors / Finishes S7361201 - Chrome S7361202 - PVD Satin Nickel S7361203 - Antique Bronze
BREAK DOWN Component Parts List 36 35 34 33 32 31 30 29 28 27 26 25 24 23 22 21 20 19 18 17 16 15 14 13 12 11 10 9 8 7 6 5 4 3 2 1 NO.
CTPB0501 ATBA0127 CTXB0043 CTQP0029 CTWR0021 CTYB0057 CTRR0031 CTNB0037 CTRR0045 CTMB0145 CTWR0053 CTNB0059 CTWT0038 CTWR0090 CTWR0270 CTWB0102 ATBP0182 CTRR0013 CTST0137 ATBF0173 ATBP0157 CTPB0500 ATBA0128 CTNZ0011 CTNT0022 CTWT0065 CTWR0276 CTWR0025 CTLZ0026 CTCZ0228 CTRR0149 CTRP0082 CTHZ0462 CTST1013 CTRR0029 CTHB0064 Drawing No.
SHANK CARTRIDGE HOUSING FLOW REGULATOR GASKET T-CONNECTOR O-RING CONNECTOR O-RING ADAPTOR GASKET NUT WASHER WASHER WASHER GASKET SPOUT O-RING SCREW SPOUT HOSE SHANK CARTRIDGE NUT NUT WASHER GASKET GASKET FLANGE ESCUTCHEON O-RING C-RING HANDLE SCREW O-RING CAP Part Description
Note: Summit Series ONLY
17 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 2 1 1 2 2 2 2 2 2 2 2 2 2 2 2 2 Quantity
32 33 34 18 1
19
2
20
3 4 5 6
21
7
22
8
23
9
24
10
25
11
26
12
27
13
28
14
29
15
35
36
30
31 16
FA-7
4/2017
Faucets Huntington Brass Sherington 4” Center Set Trim Specification Break Down
_ 3 1”
3” 4
8_
7” 8
4
7_
6” 2” _ MAX 1 1” 2
_ 2 1” 2
1/2-14NPSM
Item Number
S7361201, S7361202, S7361203
Note: Summit Series ONLY
Type
Date
4-5-2016
FA-8
4/2017
Live Wire II
Flooring
11 oz. Nylon Yarn
Shaw Carpet
Basket Weave
Brownwood
Rockslide
Twine
Tavern Grey
Believe It 25 oz. Polyester
Mink
Tactile
Macrame
25 oz. Polyester
25 oz. Polyester
Teak
Woodsmoke
Angora
Cloudburst
Angora
Cloudburst
Coconut Shell
Peat
Peat
Truffle
Pumice Stone
Sand Dollar
Spicewood
Truffle
Dunes
Sea Salt
Townhouse
Winter White
Freshen Up 40 oz. Polyester
Chamois
Cold Water
FL-1
4/2017
Flooring Believe It Carpet Technical Info 100SE - Believe It 13'7" 101SE - Believe It 15'3"
FL-2
4/2017
Flooring Textile Carpet Technical Info 102SE - Macramé 13'7" 103SE - Macramé 15'3"
104SE - Tactile 13'7" 105SE - Tactile 15'3"
FL-3
4/2017
Flooring Macrame Carpet Technical Info 102SE - Macramé 13'7" 103SE - Macramé 15'3"
104SE - Tactile 13'7" 105SE - Tactile 15'3"
FL-4
4/2017
Flooring Freshen Up Carpet Technical Info 131SE - Freshen Up 15'3"
FL-5
4/2017
Flooring Luxflor Vinyl Flooring
LX241
LX245
LX285
LX276
LX286 FL-6
4/2017
Flooring Armstrong Vinyl Flooring
White Wash Walnut
Oak Etched Tan
Hickory Scraped Homestead
FL-7
4/2017
Flooring NAFCO Vinyl Tile
Indian Slate Verde
Limestone Bark
Weathered Beach
FL-8
4/2017
Flooring SHAW Vinyl Tile
Roma
Genoa
Parma
FL-9
5/2017
Misc Interior LED Can Lights
110v LED RECESS ED LIGHTING
+LȍK &RORU 5HQGHULQȍ ,QGH[ UHQGHUV FRORUV EULȍKW DQG WUXH
4XLFȒ ZLUH FRQQHFWRUV IRU HDV\ LQVWDOODWLRQ
%XLOW LQ GULYHU IRU VXSHULRU GLPPDELOLW\
- ER[ PHHWV FXELF FDSDFLW\ UHTXLUHPHQWV IRU +8' DQG 0RGXODU +RXVLQȍ FRGHV
KRXU OLIHVSDQ $SSURYHG IRU DQG ȍDXȍH ZLUH 6SULQȍ FOLSV IRU HDV\ LQVWDOODWLRQ
/D6DOOH %ULVWRO _ &RXQW\ 5RDG _ (OȒKDUW ,1 _ _ ZZZ ODVDOOHEULVWRO FRP
MI-1
4/2017
Misc Interior LED Can Lights cont.
110v LED RECESS ED LIGHTING
4” Recessed
6” Recessed
Model
410D304N
410D316N
Height
4.25 Inches
4.5 Inches
Width
5.75 Inches
7.625 Inches
Rough Opening
4.5 Inches
6.5 Inches
White
White
110V AC
110V AC
Frequency
60Hz
60Hz
Power
10.5W
15W
Dimmable
Yes
Yes
CRI
>90
>90
650-690 lms
1050-1150 lms
3,000
3,000
Luminous Flux
>65
>65
Beam Angle
93°
95.6°
50,000 hours
50,000 hours
Finish Voltage
Lumens Color
Life time
Ratings
• IC • Air Tight • Wet Location MI-2
4/2017
Misc Interior Sweep-O-Vac SVS1500 SVP1500
OPERATING MANUAL English/Spanish Model No: SVS1500 – Model No:SVP1500 SAVE THESE INSTRUCTIONS Contents Section 1 Warning: Installation Warning: Operation Warning: Disposal
2 2 3
Section 2 Instructions for use Changing the bag and filter Fitting Instructions
4 5 6
Section 3 Specifications Dimensional Information
9 9
Section 4 Troubleshooting Warranty
10 11
www.sweepovacusa.com MI-3
4/2017
MI-4
2
A6 If for any reason, it becomes necessary to replace a fuse, please consult an electrician to ensure that any new fuse is fitted correctly and complies with local building codes. A7 If the supply cable of the appliance is
A4 Ensure any extension leads used are suitable and in good condition. Please consult an electrician if in doubt. A5 If removal of the supplied plug-top is required for installation, or replacement, it must be re-connected properly ensuring that the live and earth coloured wires are inserted correctly. PLEASE CONSULT AN ELECTRICIAN. Always ensure that the cable clamp is fitted and that it clamps the cable outer and NOT the coloured wires.
A3 Ensure power can be switched off at the electrical panel.
A2 The appliance must be plugged into an outlet, located so that power can be readily removed from the appliance for the purpose of maintenance, cleaning and similar purposes.
A1 Installation must be carried out strictly in accordance with the supplied installation instructions.
To reduce the risk of fire, electric shock, or injury:
WARNING: INSTALLATION
Please read through these operating instructions carefully. Please study and observe the safety instructions on the first few pages of this booklet. Please observe all cautionary markings in this manual, on the vacuum bags and on the Sweepovac vacuum appliance. Please keep these operating instructions for later reference and pass them on to any person carrying out cleaning, maintenance or repair, or to any subsequent owner of the appliance.
Dear Customer,
IMPORTANT SAFETY INSTRUCTIONS
B5 Do not operate the Sweepovac vacuum when the drawer is removed.
B3 It is not designed to pick up small sharp objects, such as pins, paper clips, small toys, etc. B4 Do not use without a clean dust-bag and filter in place. To do so can damage the appliance, and invalidate your warranty.
B1 The Sweepovac unit is designed to handle normal dry dust and debris in a domestic or office environment. It is not designed to handle water, or superfine industrial dust. Do not install or use the Sweepovac vacuum outdoors, in a bathroom, a wet area, within 10 feet (3.1m) of a pool. Do not expose to moisture, rain or snow. Do not pick up water or sweep water into the Sweepovac vacuum. B2 Do not pick up water, or any other liquid. This will cause the product to fail, and invalidate your warranty.
To reduce the risk of fire, electric shock, or injury:
WARNING: OPERATION
Left hand and right hand side of the machine body- collectively – 3”. No extra ventilation is required.
Rear of the machine to nearest surface – ¾”. Top and bottom of the body of the machine to nearest surfaces – 1/16”.
The vacuum must have the following clearances when fitted;
A8 Fitting Clearances:
damaged, disconnect the appliance from the outlet immediately. The complete Sweepovac electrical module will have to be replaced. This should be carried out by Sweepovac USA only, or its appointed agent. If in any doubt please consult a qualified electrician or Sweepovac USA directly
Section 1
C1 The materials used in this product
To reduce the risk of fire, electric shock, or injury:
WARNING: DISPOSAL
B14 Do not disassemble the Sweepovac vacuum as incorrect assembly may result in electric shock, malfunction or fire.
B12 Do not place any objects inside the Sweepovac chamber when the drawer is removed. B13 Do not put your hand inside the Sweepovac chamber when the drawer is removed.
B11 Do not sweep in anything that is burning or smoking, such as cigarettes. Do not sweep in hot or warm ashes from a stove, fireplace etc.
B10 Do not sweep any combustible or flammable material such as gasoline or lighter fuel into the Sweepovac.
B9 Do not allow to be used as a toy. Close attention is necessary when used by children. Children should be supervised to ensure that they do not play with the Sweepovac vacuum.
B7 Always remove the plug from the wall or switch off power at the electrical panel before attempting any form of user maintenance or cleaning as specified in this booklet. B8 This Sweepovac vacuum device is not intended for use by young children or infirm persons with reduced physical, sensory or reasoning capabilities, or lack of experience and knowledge, unless they have been given supervision or instruction by a responsible person concerning use of the Sweepovac vacuum to ensure that they can use safely.
B6 Do not fit anything other than original Sweepovac dust bags or filters. To do so can damage the appliance, and invalidate your warranty.
3
C3 If disposing of this product, please contact your local authority or the retailer where the product was purchased. In the event of difficulty, please contact Sweepovac USA. directly.
C2 The symbol shown below and on the product, means that it is classed as Electrical or Electronic Equipment and should not be disposed with other household or commercial waste at the end of its working life.
comply with international EU Directives on the Restriction of Hazardous Substances (RoHS)
Section 1
Misc Interior Sweep-O-Vac
4/2017
4
5
3
1
4
2
when the bag is full this light will come on during normal operation
Clean the brush head by rubbing the bristles over the powerful suction.
Tap the lower part of the switch gently with the broom or with your foot.
Cleaning: To clean the front face of the Sweepovac. Unplug or switch off at the electrical panel. Rub the front using a slightly dampened cloth.
Tap the switch to turn off OR allow the ten second timer to automatically turn off the unit.
Sweep in the dirt.
Sweep dirt to a point in front of the Sweepovac.
INSTRUCTIONS FOR USE
Section 2
5
3
1
Push the drawer home until it clicks back into place.
Replace the bag as shown every 12 weeks (for normal domestic use). The bag can be changed at the appliance or the entire drawer can be carried to the garbage can and the bag disposed of there. Ensure the three cardboard lugs are slotted home.
Hold the bag upright when removing to prevent dirt spilling out.
Slide out the bag drawer.
CHANGING THE BAG AND FILTER
It is recommended to change the filter every year or if it appears dirty on visual inspection.
Press down the bag release catch to clip in or to remove the bag.
Change the bag every 12 weeks (for normal domestic use) and the filter every 12 months.
1. If the light flashes on when in use. 2. If it is unable to suck up all the dirt. 3. If dirt has to be brushed right into the opening to be vacuumed up. 4. If the motor sound changes.
HOW DO YOU KNOW THE BAG IS FULL?
4
2
Section 2
5
Misc Interior Sweep-O-Vac
MI-5
4/2017
6
1
Take the Sweepovac from the box and remove the 4 hex head screws holding the face plate on.
How to fit the unit
2
Template for marking the cut out
Remove the faceplate
T4 * No 6 flathead Philips wood screws - ¾ “ long
Tools required O Pencil or fine point marker O 7/64 inch (2.5mm) hex head/alan key (included) O Philips head screwdriver No 2 O Jigsaw or sawzall O Cut out template (included) O 1/2” to 1” drill bit
7/64 inch (2.5mm) hex head/alan key (included)
Dust bags x 5 and Filter x 1
7
5
3
Use the levelling foot to ensure the unit will sit level when fitted.
Cut out the hole.
8
6
4
Slide in the power cable and locate it beside the outlet it will be plugged into.
Hole in the cabinet.
Drill corner holes
Section 2
Place template against the surface and mark with a fine tipped pen.
How to fit the unit
Contents
The Sweepovac unit
FITTING INSTRUCTIONS
FITTING INSTRUCTIONS
Section 2
7
Misc Interior Sweep-O-Vac
MI-6
4/2017
8
13
11
Screw on the face plate.
Unit in place.
Plugs into a normal outlet.
14
12
10
Insert the filter.
Screw into place using the 4 wood screws.
Slide in Sweepovac unit.
Insert the bag.
Unit is fully fitted. Well done.
Side
Front
DIMENSIONAL INFORMATION
650 watt
Motor:
O.5 gallon. The bag must be changed every 12 weeks (for normal domestic use.) It is recommended to change the filter once a year or if it appears dirty on a visual inspection.
Sweep-O-Vac
MI-7
9
View of the part of Sweepovac that is inserted beneath the kitchen unit.
50g brown outer paper + 30g spun-bound non woven with antibacterial agent. Micro filtration. Bag pre-filled with carbon particles for extra anti bacterial effect.
Bag Specification:
Bag capacity:
The switch is on a 10 second timer and will turn off automatically after 10 seconds. Gently kick or tap the bottom part of the switch. Kick once for on. Kick once for off. Automatic turn off (10 sec timer). Stroke movement of switch: 1/8 inch.
Section 3
16
Section 2
Switch:
SPECIFICATIONS
15
How to fit the unit
How to fit the unit
9
FITTING INSTRUCTIONS
FITTING INSTRUCTIONS
Section 2
Misc Interior
4/2017
10
To remove the entire Sweepovac appliance from it’s location. Consult the fitting instructions that accompanied this manual, ensure that the Sweepovac is disconnected from the power before removal.
If none of the above are effective. Contact an electrical repair shop or Sweepovac if the warranty is still valid.
Ensure the Sweepovac is unplugged. Remove the bag drawer. Visually inspect the rear of the cavity where the bag drawer sits. A grill at the rear protects the motor. This grill should be free from any obstruction.
To check for and remove a blockage at the motor inlet.
Remove the bag drawer, hold the drawer vertically with the front pointing upwards, this will allow the sweepings to fall to the rear of the bag. Lay the drawer flat, remove the bag, insert a single finger through the bag holding pipe, any obstruction will be felt and can be removed. A finger can also be inserted into the outside opening where the dirt is vacuumed through.
To check for and remove a blockage at the inlet aperture.
Unplug from the outlet. Remove the bag drawer and use the hose of a normal vacuum cleaner to clean out the internal cavity of the Sweepovac. Replace the filter and insert a new bag.
If you accidentally operate the Sweepovac without a bag.
Warranty assistance includes: Replacement of unit if deemed faulty. Please note that the
The Sweepovac motor has a thermal cut out. If the motor overheats, check for blockages and wait for one hour before operating again. Check that other outlets in close proximity to the Sweepovac are working. Check the electrical panel for the house.
5. During the warranty period, Sweepovac, or its authorized agents, will, at no extra charge and subject to these terms and conditions, repair or replace any parts which it considers to be defective.
4. The warranty only applies to products that have been operated and maintained in accordance with the enclosed Sweepovac Operation/Maintenance Manual.
3. The warranty only applies to products that have been installed in accordance with the enclosed Sweepovac installation instructions.
2. The warranty period is 24 months from the registered date of purchase.
1. Sweepovac warrants that, when dispatched from a Sweepovac warehouse, the appliance is free from defects in materials and workmanship for the warranty period.
General Terms and Conditions
www.sweepovacusa.com
We hope you enjoy your Sweepovac.
8. Proof of purchase is required before you can make a claim under this warranty.
11
7. The warranty does not apply in the following situations: a. Incomplete or improper installation. b. Vacuuming of very fine dust or wet materials. c. Use without recommended dust-bags or filter. d. Use of non-recommended dust bags or filters. e. Normal wear and tear. f. Failure to properly maintain or service.
6. This warranty does not apply to dust bags, filters, accessories or similar consumable parts.
checked against the trouble shooting section in this manual before removal and dispatch to Sweepovac. Please contact a registered electrical contractor to replace any damaged cables immediately.
allowing water to come into the machine or near the electrical parts inside the machine. Ensuring that wet debris or heavy items are never vacuumed into the machine. Please insure that the unit is installed as per installation instructions. We recommend changing the vacuum bag every 12 weeks (for normal domestic use). Please ensure that any malfunction is
Normal use is described in detail in the operations section of this manual. It includes : Never
replacement unit back to the customer.
customer is responsible for the removal of the faulty unit and packaging and mailing of the unit back to Sweepovac. Sweepovac will cover the cost associated with the return of the
provide us with a copy of your proof of purchase (Invoice, sales receipt etc.). The period of warranty is calculated starting 2 weeks after this date. This is to allow for timely installation.
To gain warranty assistance in the unlikely event of the unit not working, you will need to
If the Sweepovac stops operating.
Open the drawer and check if the bag is full. When changing the bag, make sure to hold the bag tray with the front pointing upwards. This will prevent any dirt falling back out through the opening. Replace old bag with a new bag. The filter located at the rear of the bag tray can be changed if it appears dirty on visual inspection. Try again.
WARRANTY Dear Customer, Thank you for purchasing a Sweepovac unit. The Sweepovac unit and associated products are designed and manufactured to a high standard and with normal use should last many years. The warranty period on your Sweepovac unit is 2 years from the date of purchase.
TROUBLESHOOTING
Section 4
If suction reduces or the Sweepovac does not vacuum up the sweepings.
Section 4
Misc Interior Sweep-O-Vac
MI-8
4/2017
Misc Interior Sweep-O-Vac
To purchase new bags and ďŹ lters please go to: www.sweepovacusa.com or call 855-339-0010
www.sweepovacusa.com MI-9
4/2017
Misc Interior Panasonic Whole House Fan with Fan/Light Combination Adjustable Airflow for Maximum Performance
FV-05-11VKSL1
Specification Submittal Data / Panasonic Ventilation Fan Description
4" or 6" duct
Customizable Ventilation Fan/Light shall be low sone ceiling mount rated for continuous run. Fan shall be ENERGY STAR® rated and certified by the Home Ventilating Institute (HVI). Fan shall include energy efficient LED lighting. Evaluated by Underwriters Laboratories and conform to both UL and cUL safety standards.
4"
Motor/Blower: • Enclosed DC brushless motor technology rated for continuous run. • Fan ventilation rates shall be manually adjustable for 50-80-110 CFM. • Power rating shall be 120 volts and 60 Hz. • Fan shall be UL listed for tub/shower enclosure when used with a GFCI protected circuit and used in insulated ceiling (TYPE I.C.). • Fan equipped with thermal cutoff fuse. • Removable, permanently lubricated, plug–in motor. Housing: • Rust proof epoxy and polyester resin coating, 26 gauge galvanized steel body. • Integrated dual 4" or 6” diameter duct adapter. • Built-in metal flange provides blocking for penetrations through drywall as an Air Barrier, and assists with the decrease in leakage in the Building Envelope during blower door testing. • Built in backdraft damper. • Articulating and expandable installation bracket up to 24".
1 0 -1
/4"
Grille: • Attractive design using Poly Pro material. • Attaches directly to housing with torsion springs. • Includes a motion sensor cap for use as a cover when the motion sensor Plug ’n Play™ module has not been selected.
13
"
13"
Light: • Two replaceable, ENERGY STAR® rated, 7W GU24 base LED lamps
* (2) 7W GU24 base LED lamps included.
Warranty: • ALL Parts: 3 Years from original purchase date. DC Motor: 6 Years from original purchase date. LED: 5 years from original purchase date.
FV-05-11VKSL1
Architectural Specifications: Customizable Ventilation Fan/Light shall be ceiling mount, ENERGY STAR® rated type with multi-speed control (0, 30-100 CFM, in 10 CFM increments) that shall be built-in with a high/low adjustable delay timer and activated by a wall switch, Motion Sensor Plug 'N Play™ module or Condensation Sensor Plug 'N Play™ module. Features a built-in speed selector. Select from 50/80/110 CFM and no more than <0.3/<0.3/0.4 sone as certified by the Home Ventilating Institute (HVI) at 0.1 w.g. with no less than 53/86/114 CFM and no more than <0.3/0.6/0.9 sones at .25 w.g. Power Consumption shall be no greater than 3.2/5.8/11.1 watts at 0.1 w.g. and 6.6/11.1/17.6 watts at 0.25 w.g. ENERGY STAR® rated with efficiency of no less than 12.8/13.3/9.9 CFM/watt at 0.1 w.g. and than 7.7/7.7/6.3 CFM/watt at 0.25 w.g. The motor shall be enclosed with brushless DC motor engineered to run continuously. DC motor speed shall automatically increase when the fan senses static pressure to maintain selected CFM. Power rating shall be 120v/60Hz. Duct diameter shall be no less than 4", inclusive of an integrated dual 4" or 6" duct adapter. Plug 'N Play™ modules provide up to two additional features. Select from Condensation Sensor, LED Night Light and Motion Sensor. Fan shall be UL and cUL listed for tub/shower enclosure when used with a GFCI protected circuit. Fan can be used to comply with ASHRAE 62.2, LEED, ENERGY STAR®, IAP, EarthCraft, California Title-24 and WA Ventilation Code. Lamps shall be of the LED type with the fan utilizing no less than two 7 Watt, ESTAR rated, GU24 base LED lamps.
Performance Curve 4" or 6" duct
FV-05-11VKSL1 with Built-in Multi-Speed PnP
DC Motor Technology: When fan senses static pressure, its speed is automatically increased to ensure that the desired CFM is not compromised, which allows the fan to perform as rated.
For complete Installation Instructions visit us.panasonic.com/ventfans
MI-10
4/2017
Misc Interior Panasonic Whole House Fan with Fan/Light Combination FV-05-11VKSL1
Adjustable Airflow for Maximum Performance
Plug 'N Play™ Modules Plug 'N Play™ modules provide up to two features (multi-speed is already built-in to FV-05-11VKSL1). Select from Motion Sensor, Condensation Sensor and LED Night Light.
FV-VS15VK1: Multi-Speed with Time Delay - N/A for this Fan, already built-in. Allows you to select the proper CFM settings to satisfy ASHRAE 62.2 continuous ventilation requirements. The fan runs continuously at a pre-set lower level (0, 30-100 CFM, in 10 CFM increments), then elevates to a maximum level of operation (50-80-110 CFM) when the wall switch is turned on, or when the motion sensor or Condensation Sensor module is activated. A High/Low delay timer returns the fan to the pre-set CFM level after a period of time set by the user.
FV-MSVK1: Motion Sensor Automatically activates when someone enters the room. Once the settings have been applied, the fan becomes truly automatic. This module also activates a 20 minute delay off timer for the fan.
FV-CSVK1: Condensation Sensor Helps control bathroom condensation to prevent mold and mildew. Sensor technology detects relative humidity and temperature to anticipate dew point, automatically turning the fan on to control humidity. Built-in Relative Humidity (RH) sensitivity adjustment enables fine tuning for moist conditions and for satisfying CalGreen requirements. When the condensation sensor is used in conjunction with multi-speed functionality, the fan will kick up to high speed when the condensation sensor detects moisture in the room. This module also activates a 20 minute delay off timer for the fan.
FV-NLVK1: LED Night Light A photocell automatically turns on the 1 watt LED night light when darkness is sensed in the room. High/Low brightness switch enables you to fine tune the photocell to work in conjunction with the darkness level of your bathroom. This module also activates an automatic 20 minute delay off timer for the fan.
Fan Specifications Static Pressure in inches w.g. Air Volume (CFM) Noise (sones) Power Consumption (watts) Energy Efficiency (CFM/Watt) Speed (RPM) Current (amps) MAX. Current (amps) Power Rating (V/Hz) ENERGY STAR rated
0.1 110
0.25 114
0.1 100
0.25 105
0.1 90
WhisperGreen Select™: FV-05-11VKSL1 0.25 0.1 0.25 0.1 0.25 0.1 0.25 0.1 94 80 86 70 71 60 62 50
0.25 53
0.1 40
0.25 43
0.1 30
0.25 35
0.4 11.1 9.9 960 0.12
0.9 17.6 6.3 1237 0.17
<0.3 8.7 11.6 926 0.09
0.8 15.0 7.1 1213 0.15
<0.3 7.0 13.1 872 0.08
0.6 12.8 7.5 1184 0.13
<0.3 6.6 7.7 1081 0.07
<0.3 2.8 14.6 739 0.04
<0.3 5.7 7.7 1077 0.06
<0.3 2.5 12.8 731 0.03
<0.3 5.0 7.4 1058 0.06
<0.3 5.8 13.3 837 0.07
0.5 11.1 7.7 1157 0.12
<0.3 0.4 4.7 8.9 15.3 8.2 796 1119 0.05 0.09 0.42 120/60 Yes
<0.3 3.9 15.9 769 0.05
0.3 7.6 8.4 1102 0.08
<0.3 3.2 12.8 740 0.04
0.25=Installed Performance
MI-11
4/2017
Misc Interior Standard 200 Amp Electrical Panel Box
Cutler-Hammer Type BR Loadcenters Product Focus
• Quality Residential Products • Ease of Installation • Save Time and Money
The Leading Value in Loadcenter Performance and Quality
MI-12
4/2017
Misc Interior Standard 200 Amp Electrical Panel Box
Quality Without Compromise When you want to get the most for your Loadcenter investment, there’s only one place to turn. CutlerHammer’s line of BR Loadcenters delivers all the features and benefits you expect from a high-quality piece of equipment at exceptional values you won’t find anywhere else.
Yet, Cutler-Hammer’s BR Loadcenters do more than save you time and money. They also deliver peace of mind…for yourself and your customers. For too many suppliers, providing value means cutting back on quality. Not so with Cutler-Hammer. That’s why it pays to go with the name you trust.
EATON CORPORATION Cutler-Hammer Type BR Loadcenters • www.EatonElectrical.com • 1-800-525-2000
MI-13
4/2017
Misc Interior Standard 200 Amp Electrical Panel Box
Safety And Reliability
Electrical contractors and builders like you will also find peace of mind in the performance features we build into our BR Loadcenters. For instance, all of our Loadcenters are equipped to use Arc Fault Circuit Interrupters, which protect circuits from dangerous arcing faults responsible for so many residential fires, and Ground Fault Circuit Interrupters to protect people from deadly shock hazards while protecting appliances too.
We also offer a standard 10-year warranty on all BR breakers and panels, along with a full line of specialty breakers such as GFCI, switching neutral, hot water heater and HID-rated breakers.
To learn more about CutlerHammer’s value line of BR Loadcenters, or to find an authorized dealer near you, call 1-800-525-2000 or visit www.EatonElectrical.com.
Add it all up and you get a combination of labor-saving, performance, safety and reliability features that is simply unprecedented in such an engineered value package.
MI-14
4/2017
Misc Interior Standard 200 Amp Electrical Panel Box
Features, and
Benefits Functions
Tangential main knockout. Extra 1-1/2-inch (38.1 mm) knockout for bundling of wires.
Standard 14-3/8 inches (365.1 mm) wide enclosures fit snugly between wall studs.
Same size Allen wrench can be used for phase and neutral lugs.
Drywall marking on enclosure.
Commercial grade main breaker designed for straight-in wiring that allows for top or bottom feed. Twin neutral design for easier wiring and balancing of the load, located in wireway, away from circuit breakers.
Factory pre-attached neutral bonding strap.
Maximum wiring gutter space for ease of wiring in compliance with NEC requirements.
Predrilled mounting holes for ease of installing ground bar kits.
One piece roll formed metal backpan with circuit breaker alignment notches assures accurately aligned breaker and bus stabs.
Maximum variety of concentric knockouts, at rear and sides. Six mounting holes (three top, three bottom) for ease of installation.
Type BR Loadcenter
Combination trim has sliding latch and adjustable deadfront for neat, clean appearance.
EATON CORPORATION Cutler-Hammer Type BR Loadcenters • www.EatonElectrical.com • 1-800-525-2000
MI-15
4/2017
Misc Interior Standard 200 Amp Electrical Panel Box
Easy To Install
As an electrical contractor or builder, you have two major cost centers: products and labor. With Cutler-Hammer's BR Loadcenters, you have the opportunity to save. To see how, we invite you to compare this list of features and benefits with any comparable Loadcenter on the market.
Tangential Main Knock-Out
Fits Snugly Between Drywall Studs
Eliminates the need for conduit offsets, which permits faster, easier installation.
BR Loadcenters feature standard 14_-inch wide enclosures to fit between wall studs.
Twin Neutral Design
Variety of Mounting Holes and Knockouts
Allows for easier wiring and balancing of the load in the wireway, away for the circuit load.
Top and Bottom Wire Feed The commercial-grade main breaker is designed for straightin wiring, horizontal mounted for top and bottom wire feeds.
Extra 1.5-Inch Knock-Out for Bundling BR Loadcenters feature the maximum wiring gutter space allowable under NEC compliance requirements.
Galvanized Steel Enclosure
Concentric knockouts are provided at the top, bottom, rear and sides of BR Loadcenter for easy wiring. Six mounting holes (three at the top of the breaker and three at the bottom) make installation a breeze, too.
Minimal Tool Requirements BR Loadcenters feature Robertson slotted square combo screwheads, which means only one screwdriver is need for installation. In addition, phase and neutral lug nuts can all be installed with the same-sized allen wrench.
Galvanized steel enclosure for maximum durability.
Easy Circuit Breaker Alignment
Drywall Marking Enclosure
BR Loadcenters are manufactured with a one-piece roll formed metal backpan. Circuit breaker notches already aligned.
The proper mounting depth for flush applications is indicated right on the breaker box. An adjustable deadfront and sliding latch are designed for a neat, clean appearance on the wall.
Other features include …
• Factory-Installed Ground Bar Kits
Full Line of Renovation Loadcenters
• Factory Pre-Attached Neutral
Our uniquely designed renovation panels have features making service upgrades quick and easy.
• Single-Piece Aluminum Bus • 1-Inch Type Breakers
• UL listed terminal blocks for
Warranty
cable splicing
• Stacked neutrals at the top of
Bonding Strip
Ten year warranty on all breakers and loadcenters.
the loadcenter to account for short wires
• Available in 11.25" width for easy replacement of old fuse boxes
EATON CORPORATION Cutler-Hammer Type BR Loadcenters • www.EatonElectrical.com • 1-800-525-2000
MI-16
4/2017
Misc Interior 40 & 50 Gallon Electric Water Heater
COMMERCIAL-GRADE RESIDENTIAL ELECTRIC WATER HEATERS
PROLINE® COMMMERCIAL-GRADE RESIDENTIAL ENHANCED HEATING ELEMENTS
CODE COMPLIANCE
• Dual 4500 watt elements for faster recovery and reliable operation.*
• Meets UBC and ICC National Codes and listed with CEC.
• Incoly stainless steel lower element lasts longer than a standard copper element.
• Complies with the Federal Energy Conservation Standards effective April 16, 2015, in accordance with the Energy Policy and Conservation Act (EPCA), as amended.
SELF CLEANING DIP TUBE • Helps reduce lime and sediment buildup, maximizes hot water output. Made from long-lasting PEX cross-linked polymer.
HIGH ENERGY FACTORS • Eco-friendly non-CFC foam insulation, heat traps and other features combine to yield a higher Energy Factor that maximizes savings on operating costs.
COREGARD™ ANODE ROD • Our anode rods have a stainless steel core that extends the life of the anode rod allowing superior tank protection far longer than standard anode rods.
BLUE DIAMOND® GLASS COATING • Provides superior corrosion resistance compared to industry-standard glass lining.
ENHANCED-FLOW BRASS DRAIN VALVE • Our residential water heaters have a solid brass, tamper resistant, enhanced-flow, ball type, drain valve.
APPROVED FOR MANUFACTURED HOUSING • All residential electric water heaters are compliant with HUD Standards for mobile homes/manufactured housing.
CERTIFIED TO UL 174 FOR HOUSEHOLD ELECTRIC WATER HEATERS CSA CERTIFIED AND ASME RATED T&P RELIEF VALVE DESIGN-LISTED BY UNDERWRITERS LABORATORIES • Certified at 300 psi test pressure and 150 psi working pressure. • Listed according to UL 174 standards governing storage tank-type electric water heaters.
6-YEAR LIMITED TANK AND PARTS WARRANTY • For complete information, consult written warranty or go to statewaterheaters.com.
• Uses a standard female hose fitting that allows for fast and easy draining during maintenance. • Designed for easy operation, this valve includes an integral screwdriver slot that features a ¼ turn (open/close) radius, which not only permits full straightthrough water flow but also a quick and positive shut off. *Model EN6 20 SOLS has a single element.
SOLID. STATE. © February 2017 State Water Heaters. All rights reserved www.statewaterheaters.com | 800-365-0024 Toll-Free USA | State Water Heaters | 500 Tennessee Waltz Parkway | Ashland City, TN 37015
Page 1 of 2 SRESS00117
MI-17
4/2017
Misc Interior 40 & 50 Gallon Electric Water Heater
COMMERCIAL-GRADE RESIDENTIAL ELECTRIC WATER HEATERS
State
Gallon Capacity
First Hour Rating Energy Factor Gallon
Element Wattage 240V
Dimensions in Inches
Recovery @ 90°F Rise Gallon Per Hour
Standard
Maximum
A
B
C
Approx. Shipping Weight (lbs)
Tall Models †EN6 30 DORT
30
47
0.95
21
4500
6000
46-1/2
39-1/2
19
95
†EN6 40 DORT
40
50
0.95
21
4500
6000
61-1/4
53-1/4
18
118
†EN6 50 DORT
50
73
0.95
21
4500
6000
60-1/2
51-1/4
20-1/2
125
†EN6 55 DORT
55
76
0.94
21
4500
6000
56-1/2
48-1/2
24
145 95
Short Models 30
48
0.95
21
4500
6000
39
30-1/2
20
†EN6 30 DORS
EN6 30 DOBS*
30
49
0.95
21
4500
6000
39-3/4
30-1/2
22
94
†EN6 40 DORS
40
55
0.95
21
4500
6000
49-3/4
40-3/4
20-1/2
109
†EN6 50 DORS
50
62
0.95
21
4500
6000
49-1/4
40-3/8
23
161 65
Lowboy Top Connect Models 19.5
N/A
N/A
21
4500
6000
30
21-1/4
20
†EN6 30 DOLBS*
EN6 20 SOLS
28
40
0.95
21
4500
6000
30
21-3/4
20
90
†EN6 30 DOLS
28
42
0.95
21
4500
6000
30
21-3/4
22
115
†EN6 36 DOLS
36
46
0.95
21
4500
6000
32
24
24
118
†EN6 40 DOLBS*
38
44
0.95
21
4500
6000
32
24
23
118
†EN6 50 DOLBS*
48
57
0.95
21
4500
6000
34
25
26-1/2
172
Male 3/4”water connections on 8” center. *Models ship with supplied insulation blanket. †For 10-year tank and 6-year parts limited warranty, change “N6” to “SX” in select models and “R” to “N” in tall and short model number (example: ESX 40 DONT). EN6 20 SOLS is a single element configuration only Optional top T&P location #2 is used on EN6 50 DORT, EN6 55 DORT, EN6 40 DORS and EN6 50 DORS. Optional top T&P location #3 is used on EN6 50 DOLBS, EN6 30 DOLBS,EN6 30 DOLS, EN6 40 DOLBS and EN6 36 DOLS. Top T&P is not available on the 10 year lowboy models. Dimensions and specifications subject to change without notice in accordance with our policy of continuous product improvement.
T&P VALVE ACCESS PANEL
ANODE (OR OPTIONAL TOP T&P LOCATION #1) OPTIONAL TOP T&P LOCATION #3 OPTIONAL TOP T&P LOCATION #2 JUNCTION BOX
ACCESS PANEL DRAIN VALVE
T&P VALVE
FOR MORE INFORMATION CONTACT: STATE WATER HEATERS 500 TENNESSEE WALTZ PARKWAY, ASHLAND CITY, TN 37015 • 800-365-0024 TOLL-FREE USA • STATEWATERHEATERS.COM
© February 2017 State Water Heaters. All rights reserved www.statewaterheaters.com | 800-365-0024 Toll-Free USA
Page 2 of 2 SRESS00117
MI-18
4/2017
Un entretein incorrect pourrait entraĂŽner un fonctionnement DANGEREUX DE L APPAREIL DES BLESSURES GRAVES LA MORT OU des dommages matĂŠriels.
s #OUPER TOUTE ALIMENTATION �LECTRIQUE AU G�N�RATEUR D AIR chaud avant de prodÊder aux travaux d’entretein. s !U MOMENT DE L ENTRETIEN DES COMMANDES �TIQUETEZ TOUS LES lLS AVANT DE LES D�BRANCHER 3 ASSURER DE LES raccorder correctement. s 3 ASSURER QUE L APPAREIL FONCTIONNE AD�QUATEMENT APR�S l’entretien.
Improper servicing could result in dangerous operation, serious injury, death or property damage.
s "EFORE SERVICING DISCONNECT ALL electrical power to furnace. s 7HEN SERVICING CONTROLS LABEL all wires prior to disconnecting. Reconnect wires correctly. s 6ERIFY PROPER OPERATION AFTER servicing.
DO NOT DESTROY. PLEASE READ CAREFULLY & KEEP IN A SAFE PLACE FOR FUTURE REFERENCE.
RISQUE DE CHOC ÉLECTRIQUE, D’INCENDIE OU D’EXPLOSION Le non-respect des avertissements de sÊcuritÊ pourrait entraÎner un fonctionnement dangereux de l’appareil, des BLESSURES GRAVES LA MORT OU DES DOMMAGES MAT�RIELS
ELECTRICAL SHOCK, FIRE OR EXPLOSION HAZARD Failure to follow safety warnings exactly could result in serious injury or property damage.
WARNING / AVERTISSEMENT
Downow & Upow Models
OWNER’S MANUAL & INSTALLATION INSTRUCTIONS
E4 Series Electric Furnace
42/5",%3(//4).' .............................................. 4
Furnace Filter...................................................................4 Coil Filters ........................................................................4 Blower Compartment .......................................................4
UNIT MAINTENANCE............................................... 4
Line Voltage Wiring..........................................................13 Connecting Supply Service Wires ...................................14 Grounding ........................................................................14 Thermostat / Low Voltage Connections ..........................14 Selecting Blower Speed ..................................................14 Changing Blower Speed ..................................................15 Blower Installation ...........................................................15 Installing Control Circuit Wiring .......................................15
Plenums & Air Ducts........................................................6 Return Air Connections .................................................6 Supply Air Connections .................................................6 Acoustical Ducts............................................................6 Unconditioned Spaces ....................................................7 Closed-Off Spaces ..........................................................7 Filtering Methods - Downow Furnaces ..........................7 Non-Ducted Return Air ..................................................7 Without A/C or H/P uncased coil: ..............................7 With A/C or H/P uncased coil: ...................................7 With optional coil housing: .........................................7 Ducted Return Air .........................................................7 Filtering Methods - Upow Furnaces...............................7 Non-Ducted Return Air ..................................................7 Without optional upow stand:......................................7 With optional upow stand:........................................7 Ducted Return Air .........................................................7 Optional Equipment .........................................................8 Return Air Grille ............................................................8 Optional Automatic Furnace Damper (901083) ............8 Duct Connectors for Downow Systems .......................8 General Information .........................................................8 Before You Install this Furnace........................................8 Locating the Unit..............................................................8 Locating & Cutting Floor Openings .................................9 Standard Duct Connector Installation .............................10 Narrow Duct Connectors .................................................10 Round Duct Connector Installation .................................11
FURNACE INSTALLATION ...................................... 8
INSTALLATION / PERFORMANCE CHECK LIST ... 24
Figure 19. E4 Furnace Components .............................16 Figure 20. E4 Furnace Physical Dimensions ................17 Figure 21. E4 Furnace Upow Stand Dimensions ........17 Electrical Data .................................................................18 Figure 22. E4EB Thermostat Connection ......................18 Table 5. Unit SpeciďŹ cations ...........................................18 Table 6. E4 Electrical SpeciďŹ cations..............................19 Wiring Diagrams ..............................................................20 Figure 23. E4EB-010H Models......................................20 Figure 24. E4EB-012H Models......................................21 Figure 25. E4EB-015H & E4EB-017H Models ..............22 Figure 26. E4EB-020H & E4EB-023H Models ..............23
&)'52%3 4!",%3 ................................................ 16
Pre-Start Check List ........................................................15 Start-up Procedures ........................................................15
START-UP & ADJUSTMENTS.................................. 15
ELECTRICAL WIRING .............................................. 13
CIRCULATING AIR REQUIREMENTS ..................... 6
Minimum Installation Clearances ....................................5 Clearances to Combustible Materials .............................5
REQUIREMENTS & CODES .................................... 5
Alcove Installation............................................................11 Closet Installation ............................................................11 Upow Furnaces ..............................................................12 Over-the-Floor Return Air System (Non-Ducted) ..........12 Through-the-Floor Return Air System (Ducted) ............13
IMPORTANT SAFETY INFORMATION .................... 5
INSTALLER INFORMATION
Cooling Operation............................................................3 Heating Operation ...........................................................3 Operating the Indoor Blower Continuously .....................3 Turning the Heater OFF ...................................................3
OPERATING INSTRUCTIONS.................................. 3
IMPORTANT SAFETY INFORMATION .................... 3
USER INFORMATION
4!",% /& #/.4%.43
Misc Interior
17kw and 20kw Furnace
MI-19
4/2017
$O NOT USE THIS FURNACE IF ANY PART HAS BEEN UNDER water. A ood damaged furnace is extremely dangerous. Attempts to use the furnace can result IN lRE OR EXPLOSION ! QUALIlED SERVICE AGENCY SHOULD BE CONTACTED TO INSPECT THE FURNACE AND to replace any electrical or control system parts THAT HAVE BEEN WET OR UNDER WATER
WARNING:
The following list of chemicals should not be used or stored near the furnace: s #HLORINATED CLEANERS s 7ATER SOFTENING CHEMICALS s $E ICING SALTS OR CHEMICALS s (OUSEHOLD #LEANING 3OLUTIONS s 0RINTING INKS PAINT REMOVERS VARNISHES ETC s #EMENTS AND GLUES s !NTISTATIC FABRIC SOFTENERS
may result in serious injury, death or property damage.
For optional A/C or H/P systems, always wait at least ďŹ ve minutes after the system shuts off BEFORE RESTARTING THE SYSTEM
CAUTION:
Change the thermostat’s system mode to OFF and the fan mode to AUTO. See Figure 1. NOTE: The system will not operate, regardless of the temperature selector setting.
Turning the Heater OFF
The continuous indoor blower operation can be obtained with the thermostat system mode set in any position, including OFF.
Set the thermostat fan mode to ON (Figure 1). The indoor blower starts immediately, and will run continually until the fan mode is reset to AUTO.
The continuous indoor blower operation is typically used to circulate the indoor air to equalize a temperature unbalance due to a sun load, cooking, or ďŹ replace operation.
/PERATING THE )NDOOR "LOWER #ONTINUOUSLY
1. Set the thermostat’s system mode to HEAT or AUTO and change the fan mode to AUTO. See Figure 1. $O NOT STORE OR PLACE mAMMABLE OR VAPOROUS materials (paint thinners, etc.) in the vicinity of 2. Set the temperature selector to the desired temperature level. The compressor, outdoor fan, and blower motor this appliance. Failure to comply may cause ďŹ re, will cycle on and off to maintain the indoor temperature EXPLOSION OR OTHER HAZARDOUS CONDITIONS WHICH at the desired heating level.
WARNING:
Heating Operation
at the desired cooling level.
Improper service, adjustment or maintenance of UNIT MAY CAUSE lRE ELECTRICAL SHOCK OR HAZARDOUS Cooling Operation conditions which may result in personal injury, 1. Set the thermostat’s system mode to COOL or AUTO and change the fan mode to AUTO. See Figure 1 (page property damage, or death. Installation or 4). SERVICING SHOULD ONLY BE PERFORMED BY QUALIlED 2. Set the temperature selector to the desired temperature trained personnel thoroughly familiar with this level.The outdoor fan, compressor, and blower motor will TYPE EQUIPMENT all cycle on and off to maintain the indoor temperature
WARNING:
NOTE: Allow at least one hour for the room temperature to stabilize before you make a second adjustment to the thermostat setting. After the desired comfort level is established, make only small adjustments to the thermostat setting to meet changing temperature conditions.
OPERATING INSTRUCTIONS NOTE: Thermostat styles vary. Some models may not include the AUTO mode and others will have the AUTO in place of the HEAT and COOL. Others may include all three. Please refer to the thermostat manufacturer’s User manual for detailed programming instructions.
IMPORTANT SAFETY INFORMATION
Safety markings are used to designate a degree or level of seriousness and should not be ignored. WARNING indicates a potentially hazardous situation that if not avoided, could result in personal injury or death. CAUTION indicates a potentially hazardous situation that if not avoided, may result in minor or moderate injury or property damage.
USER INFORMATION
System Mode
Temperature Selector
"LOWER #OMPARTMENT
If a cooling coil is installed on your unit, the furnace ďŹ lter is not used. Remove coil ďŹ lters, wash, and allow to dry. Re-install coil ďŹ lters to their original positions.
Coil Filters
s % FURNACES ARE SUPPLIED WITH A SINGLE AIR lLTER WHEN shipped from the factory. It is recommended that the ďŹ lter be cleaned or replaced monthly. Newly built or recently renovated homes may require more frequent changing until the construction dust has minimized. Filter sizes shown in Table 5 (page 18) are available at most local retailers. Inspect ďŹ lters frequently and replace when necessary with ďŹ lter of same dimensional size s &ILTERS DESIGNED TO REMOVE SMALLER PARTICLES SUCH AS pollen, may require additional maintenance.
4
CAUTION:
Dirt and lint can create excessive loads on the motor resulting in higher than normal operating temperatures and shortened service life. Vacuum or wipe clean the interior 4HERE ARE .O USER SERVICEABLE PARTS INSIDE THE of furnace cabinet. Clean all lint and dust from around the control panel. DO NOT OPEN. furnace. It is recommended that the blower compartment be cleaned of dirt or lint that may have accumulated in NOTE: All servicing of this heating appliance other than the compartment or on the blower and motor as part of the normal maintenance described in this section must regular maintenance. be done by authorized trained service personnel. Do not attempt any servicing which requires opening of the 42/5",%3(//4).' control panels. If the unit fails to operate, check the following: s 0ROPER MAINTENANCE IS MOST IMPORTANT TO ACHIEVE THE s #HECK THE THERMOSTAT SETTING -AKE SURE THE SYSTEM mode and temperature settings are correct. best performance from the appliance and should be performed frequently at the beginning of each heating s #HECK THE ELECTRICAL PANEL FOR TRIPPED CIRCUIT BREAKERS s #HECK THE lLTERS FOR DUST ACCUMULATION season. s +EEP THE AREA SUROUNDING THE UNIT CLEAN +EEP THE UNIT s #HECK THE UNIT AND MAKE SURE IT IS CLEAN AND NOT covered with grass or leaves. clear of obstructions. s )F THE ITEMS ABOVE DON T RESOLVE YOUR PROBLEMS THEN call your nearest service technician. Please specify the complete model and serial numbers shown on the furnace data label for all warranty service and when ordering replacement parts or optional equipment. Refer to the replacement parts list provided with the furnace for part numbers.
3HUT OFF ALL ELECTRICAL POWER TO THE UNIT BEFORE performing any maintenance or service on the system. Failure to comply may result in personal injury or death.
WARNING:
UNIT MAINTENANCE
Figure 1. Digital Thermostat
Fan Mode
WARNING: Never operate the furnace without a ďŹ lter in place. !CCUMULATING DUST IN THE RETURN AIR CAN BUILD up on internal components, resulting in loss of EFlCIENCY EQUIPMENT DAMAGE AND POSSIBLE lRE
Furnace Filter
USER INFORMATION
Misc Interior
17kw and 20kw Furnace
MI-20
4/2017
ALL MODELS
0" 0"
TOP & SIDES OF DUCT BOTTOM OF DUCT 0"
0"
0"
For alcove installations allow 18 (46cm) inches minimum clearance from the front of the unit for FUTURE SERVICING #LOSET INSTALLATIONS REQUIRE inches minimum. s 4HIS APPLIANCE MUST BE INSTALLED IN ACCORDANCE WITH clearances listed in Table 1. The furnace must be installed with ample clearance for easy access to the air ďŹ lter, blower assembly, burner assembly, controls, and vent connections. s ,OCATE AND INSTALL THIS UNIT IN POSITION AS SPECIlED on page 8. This unit is designed only for Indoor installations and should be located with consideration of minimizing the length of the supply and return ducts. See Table 4 (page 15) or the rating plate for circulating airow data. s 3UFlCIENT CLEARANCE FOR UNOBSTRUCTED AIRmOW THROUGH A louvered door must be maintained in order to achieve rated performance. Air return to the furnace must have the minimum required total free area: 200 in2 (1290 cm2 ) for furnace only. May also include return air grille and frame assembly P/N 902989 or wall mount grille P/N 902999). 235 in2 (1516 cm2 ) with 4 ton A.C. or H.P. installed. 250 in2. (1613 cm2 ) with 4 ton A.C. or H.P. installed & 1â€? special clearance. 390 in2 (2516 cm2 ) with up to 5 ton A.C. or H.P. installed.
4ABLE -INIMUM #LEARANCE 2EQUIREMENTS
*For upow application using upow stand, 3� minimum per side. **Service Clearance
0"
TOP
0"
0"
0" 0"
BACK
18"
ALCOVE
6"
CLOSET
SIDES*
FRONT **
s 4HE INSTALLER MUST COMPLY WITH ALL LOCAL CODES AND regulations which govern the installation of this type of equipment. Local codes and regulations take precedence over any recommendations contained in these instructions. Consult local building codes and the National Electrical Code (NEC) for special installation requirements. s !LL ELECTRICAL WIRING MUST BE COMPLETED IN ACCORDANCE with local, state and national codes and regulations and with the National Electric Code (ANSI/NFPA 70) or in Canada the Canadian Electric Code (CSA Z240.6.1, & Z240.9.1). s $ESIGN AND CONSTRUCTION OF THE HOME DUCT SYSTEM must be in accordance with: HUD Manufactured Home Construction & Safety Standard (Title 24, Part 3280) #LEARANCES TO #OMBUSTIBLE -ATERIALS and American National Standards (ANSI) A119.11, s 4HIS FURNACE IS $ESIGN #ERTIlED IN THE 5 3 AND #ANADA C1-NFPA 7 by ETL for the minimum clearances to combustible s &OLLOW ALL PRECAUTIONS IN THE LITERATURE ON TAGS AND materials. NOTE: The furnace is listed for installation on labels provided with the equipment. Read and on combustible or non-combustible ooring. To obtain thoroughly understand the instructions provided with speciďŹ c clearance information, refer to the furnace the equipment prior to performing the installation and rating plate, located inside of the furnace cabinet. operational checkout of the equipment. s v FROM ALL SURFACES OF FURNACE CABINET DUCTS OPTIONAL s 4HIS AIR HANDLER MAY NOT BE USED FOR TEMPORARY HEATING coil housing and plenum connector. No separate of buildings or structures under construction. subbase required for installations on combustible ooring. Minimum Installation Clearances s !CCESS FOR POSITIONING AND SERVICING THE UNIT MUST BE considered when locating unit. The need to provide clearance for access to panels or doors may require clearance distances over and above the requirements.
4HIS UNIT MUST BE INSTALLED IN ACCORDANCE with instructions outlined in this manual during the installation, service, and operation OF THIS UNIT 5NQUALIlED INDIVIDUALS SHOULD not attempt to interpret these instructions or INSTALL THIS EQUIPMENT &AILURE TO FOLLOW SAFETY RECOMMENDATIONS COULD RESULT IN POSSIBLE DAMAGE TO THE EQUIPMENT SERIOUS PERSONAL injury or death.
WARNING:
REQUIREMENTS & CODES
INSTALLER: Please read all instructions before servicing this equipment. Pay attention to all safety warnings and any other special notes highlighted in the manual. Safety markings are used frequently throughout this manual to designate a degree or level of seriousness and should not be ignored. WARNING indicates a potentially hazardous situation that if not avoided, could result in personal injury or death. CAUTION indicates a potentially hazardous situation that if not avoided, may result in minor or moderate injury or property damage.
IMPORTANT SAFETY INFORMATION
INSTALLER INFORMATION
s 0LENUMS AND AIR DUCTS MUST BE INSTALLED IN ACCORDANCE with the Standard for the Installation of Air Conditioning and Ventilating Systems (NFPA No. 90A) or the Standard for the Installation of Warm Air Heating and Air Conditioning Systems (NFPA No. 90B). s $ESIGN THE AIR DUCTS ACCORDING TO METHODS DESCRIBED by the Air Conditioning Contractors of America (ACCA). s !IR DUCTS MUST BE ALUMINUM TIN PLATE GALVANIZED sheet steel, or other approved materials for outlet or return air ducts. s 3NAP ,OCK OR 0ITTSBURGH ,OCK SEAMS ARE PREFERRED !LL other types of seams must be made tight to prevent leakage. s )T IS GOOD PRACTICE TO SEAL ALL CONNECTIONS AND JOINTS with industrial grade sealing tape or liquid sealant. Requirements for sealing ducts vary from region to region. Consult with local codes for requirements speciďŹ c to your area. s 'AS PIPING MUST NOT RUN IN OR THROUGH ANY OF THE AIR duct system. s !PPLICABLE INSTALLATION CODES MAY LIMIT THE FURNACE TO installation in a single-story residence only. Furnace installations other than closet or alcove require ducted return air systems.
This unit is designed only for use with a supply and return duct. Air ducts should be installed in accordance with the standards of the National Fire Protection Association Standard for Installation of Air Conditioning Systems (NFPA 90A), Standard for Installation of Residence Type Warm Air Heating and Air Conditioning Systems (NFPA 90B), and all applicable local codes. NFPA publications are available by visiting www.NFPA.org.
Plenums & Air Ducts
2ETURN AIR AND CIRCULATING AIR DUCTS MUST NOT BE connected to any other heat producing device such as a ďŹ replace insert, stove, etc. This may RESULT IN FIRE EXPLOSION CARBON MONOXIDE poisoning, personal injury, or property damage.
!LL RETURN DUCTS MUST BE SECURED TO THE FURNACE with sheet metal screws. All return ducts must BE ADEQUATELY SEALED 7HEN RETURN AIR IS PROVIDED THROUGH THE BOTTOM OF THE UNIT THE JOINT BETWEEN THE FURNACE AND THE RETURN AIR PLENUM MUST BE air tight.
WARNING:
CIRCULATING AIR REQUIREMENTS
Certain installations may require the use of acoustical lining inside the supply duct work. s !COUSTICAL INSULATION MUST BE IN ACCORDANCE WITH the current revision of the Sheet Metal and Air Conditioning Contractors National Association (SMACNA) application standard for duct liners. s $UCT LINING MUST BE 5, CLASSIlED BATTS OR BLANKETS WITH a ďŹ re hazard classiďŹ cation of FHC-25/50 or less. s &IBER DUCT WORK MAY BE USED IN PLACE OF INTERNAL DUCT liners if the ďŹ ber duct work is in accordance with the current revision of the SMACNA construction standard on ďŹ brous glass ducts. Fibrous duct work and internal acoustical lining must be NFPA Class 1 air ducts when tested per UL Standard 181 for Class 1 ducts.
Acoustical Ducts
s 3UPPLY DUCT SYSTEM MUST BE DESIGNED FOR PROPER AIR distribution. Static pressure measured externally to furnace shall not exceed static pressure rating listed on furnace nameplate. s $UCT SYSTEM MUST BE DESIGNED SO THAT NO SUPPLY registers are located in duct system directly below the furnace.
Supply Air Connections
Air return to the furnace must have a minimum free area opening. See Table 1 (page 5). A return air grille for closet or alcove installations is available. Acceptable closet installations with return air entering through an opening in the oor or ceiling of a closet, must meet all of the following requirements: s 4HE RETURN AIR OPENING REGARDLESS OF ITS LOCATION IN THE closet, must not be smaller than size speciďŹ ed on unit data label. If located in the oor, the opening must be provided with a means of preventing its inadvertent closure by at object(s) placed over the opening. s ! RETURN AIR GRILLE MUST BE USED WHEN FURNACE IS installed in a closet or alcove: Alcove installations: use return air grille & frame assembly P/N 902989 or equivalent. See Figure 2 (page 7). Closet installations: use wall mount return air grilled P/N 902999 or equivalent. NOTE: For 5 ton A.C. or H.P. system, 155 in2 (1,000 cm2 ) must be added. Downow alcove installations: the grille (with frame provided) may be attached to the top of the furnace and all paneling and trim ushed to it. This installation provides an access door for future installation of NORDYNE air conditioning or heat pump coils on top of the furnace. s -ATERIALS LOCATED IN RETURN AIR DUCT SYSTEM MUST HAVE a ame-spread classiďŹ cation of 200 or less. s .ONCOMBUSTIBLE PANS HAVING v UPTURNED mANGES must be located beneath openings in a oor-return duct system. s 7IRING MATERIALS LOCATED IN RETURN DUCT SYSTEM MUST conform to NEC Article 300-22(c). s )F RETURN AIR OPENING IS LOCATED BELOW TOP OF FURNACE a minimum clearance must be provided between opening and furnace. See Table 1.
Return Air Connections
Misc Interior
17kw and 20kw Furnace
MI-21
4/2017
Without optional upow stand: s )NSTALL A lLTER WITH A MINIMUM UNRESTRICTED MEDIUM AREA of 324 in2 below the coil cabinet/furnace assembly that is accessible for monthly cleaning or replacement by the homeowner
Furnaces may be installed with unducted or ducted return air. For unducted systems with air conditioners or heat pumps, the following optional equipment is recommended: upow stand, coil cabinet, upow duct connector, and wall mount grille.
Non-Ducted Return Air
Filtering Methods - Upow Furnaces
NOTE: Install a ďŹ lter with a minimum unrestricted medium area of 324 in2 in the duct above the coil that is accessible for monthly cleaning or replacement by homeowner.
For ducted return air systems with air conditioners or heat pumps, either providing an access panel in the duct or using the optional coil cabinet (Figure 3) is recommended. The duct system must be properly sized to account for any additional external static pressure produced from the chosen ďŹ ltering method.
Ducted Return Air
With optional coil housing: s 3EE COIL CABINET INSTRUCTIONS FOR SPECIlC lLTERING methods.
With A/C or H/P uncased coil: s 5SE THE OPTIONAL COIL lLTERS THE lLTER SUPPLIED WITH THE FURNACE IS NOT USED 2%-/6% !.$ $)3#!2$ 4()3 FILTER.
Without A/C or H/P uncased coil: s 5SE THE lLTER SUPPLIED WITH THE FURNACE -AKE SURE the ďŹ lter is installed mat side down between the ďŹ lter retainer and furnace top. See Figure 2.
For unducted return air systems, either the optional grille and frame assembly or the optional wall mount grille is recommended.
Non-Ducted Return Air
Filtering Methods - Downow Furnaces
Living space not served by, and closed off from the return air ducts to the furnace (by doors, sliding partitions, and other means) must be provided with permanent, uncloseable openings in the doors or partitions to allow air to return to the furnace from all parts of the home. Return air grilles, with a minimum open area of one square inch for every ďŹ ve square feet of living space closed off from the furnace, must be provided in the door or room partition.
Closed-Off Spaces
All duct work passing through unconditioned space must be properly insulated to minimize duct losses and prevent condensation. Use insulation with an outer vapor barrier. Refer to local codes for insulation material requirements
Unconditioned Spaces
Furnace Filter (not used with A/C or H/P)
29" (737 mm)
) mm (603 /4" 3 3 2
20" (508 mm )
s )NSTALL A lLTER WITH A MINIMUM UNRESTRICTED MEDIUM AREA of 324 in2 below the coil cabinet/furnace assembly that is accessible for monthly cleaning or replacement by the homeowner
For ducted systems with air conditioners or heat pumps, the following optional equipment is recommended: coil cabinet and upow duct connector.
Ducted Return Air
With optional upow stand: s 3TAND Figure 4 (page 8)) must use two ďŹ lters: one is supplied with the stand and the other MUST be removed from the furnace and placed in the stand. See instructions supplied with the upow stand for additional details.
Figure 3. 5PmOW #OIL #ABINET
Cabinet Insulation
Figure 2. 'RILLE 3UPPORT &RAME 'RILLE !SSEMBLY
Grille
Top of Furnace
Fasteners (4)
Frame
20� (508 mm)
FURNACE INSTALLATION
Approved installation, operation, and maintenance of this appliance must be in accordance with the listed speciďŹ cations contained in these instructions and other documents supplied with the furnace and/or optional air conditioning equipment. Unless it is noted differently in this manual, only use factory authorized kits and accessories when modifying this appliance. Refer to local authorities having jurisdiction for further information.
This appliance will provide many years of safe and dependable comfort, providing it is properly installed and maintained. Abuse, improper use, and/or improper maintenance can shorten the life of the appliance and create unsafe hazards. Please read all instructions before installing the unit.
The E4 electric furnace is designed only for indoor installations and can be readily connected to the high static duct system of a home. Units are approved for single/ multistory residential or mobile/modular/manufactured structures in upow, downow, (freestanding/closet/ alcove) conďŹ gurations.
General Information
NOTE: Since all installations are different, the sequence of these steps may differ from the actual installation. These installation procedures are suggested for typical furnace installations. /NLY QUALIlED (6!# TECHNICIANS SHOULD install this furnace.
Duct connectors are recommended for heated air distribution in under-the-oor duct systems. With this system, furnaces may be installed on combustible ooring without a separate sub-base. The furnace rear mounting plate (Figure 8 (page 10)) supplied with the duct connectors is recommended for use with this type of installation.
Duct Connectors for Downow Systems
Furnace may be equipped with the optional automatic damper when a packaged air conditioner is installed and connected to the warm air duct system. This damper (not required) prevents cooled air from discharging through the furnace cabinet, causing excessive cooling of the immediate area. Refer to the instructions supplied with the damper for details.
s 3URVEY THE JOB SITE TO DETERMINE THE BEST LOCATION for installing the unit. Consideration should be given to availability of electric power, service access, and noise. s 4HE DIMENSIONS OF THE ROOM OR ALCOVE MUST BE ABLE to accommodate the overall size of the unit and the installation clearances in Table 1 (page 5). Physical dimensions for this furnace are shown in Figure 20 (page 17). If an upow stand will be used, see Figure 21 (page 17) for component dimensions. s 4HE UNIT MUST BE LEVELED AT INSTALLATION AND ATTACHED TO a properly installed duct system. s 4HE SURFACE THAT THE FURNACE IS MOUNTED ON MUST provide sound physical support of the unit.
Locating the Unit
shipment and upon arrival should be carefully inspected for damage prior to installing the equipment at the job site. Claims for damage (apparent or concealed) should be ďŹ led immediately with the carrier. — Check the electrical supply and verify the power supply is adequate for unit operation. The system must be wired and provided with circuit protection in accordance with local building codes. If there is any question concerning the power supply, contact the local power company. — Verify the air delivery of the furnace is adequate to handle the static pressure drop of the coil, ďŹ lter, and duct work.
"EFORE 9OU )NSTALL THIS &URNACE Optional Automatic Furnace Damper (901083) — This equipment is securely packaged at the time of
A return air grille and frame assembly (Figure 2 (page 7)) is available for use in unducted return air installations. In downow alcove installations, the grille and frame assembly may be mounted directly to the top of the furnace. In closet installations, a wall mount grille is available for attachment to a door or wall.
Return Air Grille
NOTE: Refer to the instructions supplied with any additional accessories for further installation details.
/PTIONAL %QUIPMENT
Figure 4. Optional Upow Stand
Upflow Stand
20� (508 mm)
24 3/4� (628 mm)
Misc Interior
17kw and 20kw Furnace
MI-22
4/2017
OPTIONAL REFRIGERANT LINE 3 1/8� X 5 3/4�
18 5/8"
3�
20"
3�
20"
ROUND DUCT CONNECTOR
10"
CL
ROUND DUCT CONNECTORS
FOR UPFLOW FURNACES WITH
FLOOR CUT-OUT 14 1/4� DIAMETER
1 3/4" MIN.
REAR WALL OF CLOSET OR ALCOVE
STANDARD DUCT CONNECTOR
10"
CL
STD. DUCT CONNECTORS
FOR UPFLOW FURNACES WITH
FURNACE DOOR
3/4"
FURNACE DOOR
3/4" OPTIONAL REFRIGERANT LINE 4 1/4� X 3 3/4� 20"
3 3/8�
16 5/8"
5�
20"
3 3/8�
ROUND DUCT CONNECTOR
10"
CL
CONNECTORS
FLOOR CUT-OUT 14 1/4� DIAMETER FOR DOWNFLOW FURNACES WITH ROUND DUCT
2 3/8" MIN.
REAR WALL OF CLOSET OR ALCOVE
FURNACE DOOR
OPTIONAL SUPPLY WIRE ENTRANCE 3� X 6 1/4� 3/4"
FURNACE DOOR
OPTIONAL SUPPLY WIRE ENTRANCE 3� X 6 1/4� 3/4"
Figure 7. Floor Cavity
SUPPLY AIR DUCT
FLOOR OPENING
901990A 901991A 901992A 901993A
6-1/4� / (159) 8-1/4� / (210) 10-1/4� / (260) 12-1/4� / (311)
904009
904014
904013
904012
904011
904010
LY PP SU DUCT AIR
MOUNTING PLATE
Figure 8. Standard Duct Connector Installed
DUCT CONNECTOR
TOR EC NN CO TABS
L DF O WO
R OO
The standard duct connector is designed for use on ducts 12â€? in width. NOTE: Ducts narrower than 12â€? may not allow sufďŹ cient clearances for this type of installation. See Narrow Duct Connector section. 1. Center the duct connector in the oor opening with bottom tabs resting on top of the supply air duct. 2. Mark the cut-out area on the supply air duct by tracing around the connector tabs of the duct connector. See Figure 8. 3. Remove the duct connector and cut out the marked area of the supply air duct 1/4â€? larger than the actual cutout drawn. 4. Install the duct connector back in the oor opening with the bottom tabs extending into the supply air duct. 5. Install the mounting plate (Figure 8) under the back side of the duct connector. Align the screw holes in both components. 6. Secure the duct connector and the mounting plate to the wood oor with appropriate size screws. 7. Bend the connector tabs on the bottom of the duct connector upwards and as tight as possible against the supply air duct. See Figure 9. 8. Seal all connections with industrial grade sealing tape or liquid sealant.
Standard Duct Connector Installation
4ABLE $UCT #ONNECTOR 3IZES
NOTE: Dimensions shown as Inches / (Millimeter)
901989A
4-1/4� / (108)
904008
DUCT CONNECTOR SUPPLY AIR DUCT
OPTION 2
CUT HERE
OPTION 1 REMOVE THIS FLAP CUT HERE
SUPPLY AIR DUCT
NOTE: Requirements for sealing ductwork vary from region to region. Consult with local codes for requirements speciďŹ c to your area.
This attachment method should be used if there is insufďŹ cient clearance to bend the tabs on a standard 12â€? duct connector. 1. Score and cut the top of the supply air duct as indicated in Option 1 or Option 2 (Figure 10). With Option 1 choice, cut out the metal from the shaded area. 2. Fold the two aps (Options 1 or 2) up to form the opening for the duct connector. 3. Install the duct connector with the bottom tabs extending into the supply air duct. 4. Bend the tabs on the bottom of the duct connector upwards and as tight as possible against the supply air duct. See Figure 11 (page 11). 5. Form the aps (Options 1 or 2) up against the duct connector as tight as possible. 6. Secure the duct connector aps to the supply air duct with staples (3 minimum) or if a 2x block/joist is not provided, use sheet metal screws (2 minimum). NOTE: The duct connector tabs may be attached to the air duct with sheet metal screws or other suitable fasteners as long as the duct connector and the air duct are securely attached. 7. Seal all connections with industrial grade sealing tape or liquid sealant.
Narrow Duct Connectors
Figure 9. $UCT #ONNECTOR 4ABS
BEND TABS TIGHTLY AGAINST SUPPLY AIR DUCT
E
CUT HERE
Figure 10. Narrow Air Duct Openings
REMOVE THIS FLAP
CUT HERE
ER
FLOOR CAVITY
“X�
5. Determine which duct connector to use from Table 2 (page 10).
NOTE: The depth of the oor cavity (shown as “Xâ€?) in Figure 7 will determine the correct duct connector.
4. Measure from the top of the oor down to the top of the supply air duct to obtain the depth of the oor cavity.
Figure 6. Cut-Out Dimensions for Downow Furnaces
OPTIONAL REFRIGERANT LINE 4 1/4� X 3 3/4�
5�
FURNACE OUTLINE
STANDARD DUCT CONNECTOR
10"
CL
FURNACES WITH STD. DUCT CONNECTORS
901988A
TH
3. Cut out the oor opening 1/16� larger than the actual cutout drawn. This will allow some clearance when installing the duct connector.
NOTE: Additional provisions may be necessary for optional air conditioning or heat pump if refrigerant lines are installed elsewhere than at the front of the furnace. The refrigerant and entrance supply opening dimensions may be adjusted ¹ 1/2�.
Floor cut-outs must be carefully located to avoid misalignment of the furnace and air duct. Standard and round cutouts for upow furnaces are shown in Figure 5. The cutouts for downow furnaces are shown in Figure 6. 1. Measure and mark the centerline of the cutout. Provide minimum clearances at rear and right side walls of closet or alcove for installation of furnace and wiring. 2. Using the centerline as a starting point, draw the rest of the duct cut-out to the dimensions shown in Figure 5 or Figure 6.
Locating & Cutting Floor Openings
Figure 5. Cut-Out Dimensions for Upow Furnaces
OPTIONAL REFRIGERANT LINE 3 1/8� X 5 3/4�
18 5/8"
17" 17"
23 3/4"
23 3/4"
FURNACE OUTLINE
FURNACE OUTLINE
23 3/4" 23 3/4"
2� / (51)
FOLD FLAP HERE
SCREW DOWN
E E
901987A
CU ER
STANDARD DUCT
TH TH
7/8� / (22)
CU CU
FLOOR CUT-OUT 14 1/2� X 14 1/2� FOR DOWNFLOW
E
FLOOR CUT-OUT 17 1/2� X 14�
ER
16 5/8" FURNACE OUTLINE
NOTE: Requirements for sealing ductwork vary from region to region. Consult with local codes for requirements speciďŹ c to your area.
TH
DUCT CONNECTOR 490% 0!24 .5-"%2
ER
CU
IF FLOOR CAVITY “X� IS:
FOLD FLAP HERE
2 3/8" MIN.
FOLD FLAP HERE
REAR WALL OF CLOSET OR ALCOVE
CUT HERE
1 3/4" MIN.
FOLD FLAP HERE
REAR WALL OF CLOSET OR ALCOVE
Misc Interior
17kw and 20kw Furnace
MI-23
4/2017
DUCT FLAP
NARROW DUCT
DUCT CONNECTOR
NARROW DUCT
STAPLES OR SHEET METAL SCREWS
SCREWS MOUNTING PLATE
1. Cut alcove rough openings to minimum dimensions shown in Figure 13. 2. Attach frame assembly with four fasteners (provided or equivalent) into pre-punched holes on top of furnace. See Figure 2 (page 7). NOTE: If additional securing is required, attach each side of frame assembly to alcove opening using holes provided. 3. Attach return air grille to frame assembly by hooking grille over flange on top of frame and into channel on bottom.
Alcove Installation
NOTE: Requirements for sealing ductwork vary from region to region. Consult with local codes for requirements specific to your area.
The 14” round duct connector is designed to connect directly to a 14” flexible duct. NOTE: Flexible ducts must have a minimum temperature rating of 200° F and meet all applicable codes and standards. 1. Apply a bead of caulking, mastic, or other approved sealant around bottom side of connector. 2. Install and center the duct connector in the floor opening. 3. Install the mounting plate under the back side of the duct connector. See Figure 12. NOTE: Align the screw holes in both components. 4. Secure the duct connector and the mounting plate to the wood floor with appropriate size screws. 5. Connect the round supply duct to the underside of the duct connector and secure them with field supplied sheet metal screws. 6. Seal all connections with industrial grade sealing tape or liquid sealant.
Round Duct Connector Installation
Figure 12. Round Duct Connector Installed
14” SUPPLY CONNECTION
ROUND DUCT CONNECTOR
Figure 11. Narrow Ducts
SHEET METAL SCREWS
NARROW DUCT
DUCT CONNECTOR TABS
29" ( 737 mm)
20" (508 mm)
Furnace Front
56" (1423 mm)
27" (686 mm)
18"Nearest Wall or Partition
Return Air Grille
Figure 13. Alcove Installation
24 3/4" (629 mm)
1. Route 240V supply circuit(s) and 24V wiring to closet or alcove. See Figure 20 (page 17) for locations. 2. Remove refrigerant line knockouts in furnace only when installing indoor coil of an air conditioner or heat pump system, or for hook-up of a VentilAire accessory when the furnace is used in the upflow position. Refer to instructions supplied with accessory equipment. 3. Remove unit front door and slide back until bottom slots in rear of unit engage with both tabs of optional rear mounting plate. If mounting plate is not used, an
The steps below describe installation procedures for an under-the-floor supply duct system with a ducted or unducted return air system. Duct connectors are recommended for this application. See Table 2 (page 10).
Downflow Furnaces For typical unducted return air downflow applications, an air-conditioner or heat-pump coil can be installed by mounting the coil directly on top of the furnace without adding sheet metal cavities or cutting and trimming wood panels. Unducted return air systems may be used for closet or alcove installations.
For proper air circulation, closet installations require a return air grill installed in the door or a partially louvered door across the opening. For clearances 6” or greater, the closet must have an open free area of 235 in2 minimum. For special clearances between 1” - 5”, requirements are a louvered door with a minimum of 250 in2 (1613 cm2) free area. A fully louvered closet door is strongly recommended for both installation types. For closet installations, the return air grille mounting frame is not used since the furnace is located inside the closet. For examples of both types of installations, see Figure 14 (page 12). 1. Cut return air opening in desired position in door or wall, preferably above top of furnace. Refer to Table 1 (page 5) for return air opening requirements. 2. Insert four fasteners, securing grille to door or wall.
Closet Installation
A/C or H/P Coil
Coil Air Filters
Wall
0" Side Clearance to Furnace Cabinet
0" Side Clearance to Furnace Cabinet CLOSET DOOR
CLOSET DOOR
Figure 14. Closet Installation
Special 1" Clearance
1 (25 " mm)
Provide min. 250 sq. in. (1613 cm2 ) open free area in front or side wall or in top of closet door
Standard Closet Installation
(1526" mm)
Provide min. 235 sq. in. (1516 cm ) open free area in front or side wall or in top of closet door
4. Secure front of unit with one or more fasteners at mounting hole(s) provided or at tie-down tab. See Figure 20 (page 17). 5. See Electrical Wiring section (page 13) to complete furnace installation.
NOTE: The furnace does not need to be positoned against the rear mounting plate. The tabs will engage into the slots and allow approximately 1/2” of furnace adjustment front to back and side to side.
equivalent method of securing the rear of the unit may be used as long as it prevents displacement during transport if used in a manufactured home.
FLOOR Non-combustible Pan or Enclosure
WALL
Figure 15. Over-the-Floor Return Air System
Front Grille
Braced Mounting Platform
Air Filter
Coil Cabinet
NOTE: Be sure to provide an adequate free return air area as described in the Closed-Off Spaces section(page 7).
1. If floor underneath furnace is made of combustible material, locate a pan fabricated of non-combustible material with 1” upturned flanges under furnace return air opening. See Figure 15. 2. Use optional upflow stand (P/N 904620A) with filters or construct a suitably braced mounting platform in closet. See Figure 16 (page 13). 3. Route 240V supply circuit(s) and 24V wiring to closet. See Figure 20 (page 17) for appropriate locations. 4. Position optional coil cabinet onto upflow stand or mounting platform and secure with three or more fasteners. 5. Position furnace in upflow mode onto coil cabinet and secure with two or more fasteners. 6. Use optional upflow duct connector or field supplied connector to attach furnace to overhead supply duct. See Figure 16. 7. Install return air grille in closet preferably at same level as upflow stand or below mounting platform. See Figure 15.
Over-the-Floor Return Air System (NonDucted)
Refer to instructions supplied with accessory equipment.
NOTE: Remove refrigerant line knockouts in furnace only when installing indoor coil from an air conditioner or heat pump system.
The following steps describe installation instructions for an overhead supply duct system with a return air system that can be either over the floor (unducted) or through the floor (ducted).
Upflow Furnaces
Misc Interior
17kw and 20kw Furnace
MI-24
4/2017
1. Prepare Floor Opening(s): a. Mark oor openings as shown in Figure 5 (page 9). Provide minimum clearances at rear and left side walls of closet for installation of furnace and wiring. b. Cut oor opening on outside edge of marked line so that opening is slightly larger than area marked. c. Additional provisions may be necessary for optional air conditioning if refrigerant lines are installed other than at the front of the furnace. 2. If return air duct is made of combustible material, locate a pan fabricated of non-combustible material with 1â€? upturned anges under furnace return air opening. 3. Route 240V supply circuit(s) and 24V wiring to closet. See Figure 20 (page 17) for appropriate locations. 4. Position optional coil cabinet over oor cutout and secure with three or more fasteners. 5. Position furnace onto coil cabinet and secure with two or more fasteners. 6. Use optional upow duct connector or ďŹ eld supplied connector to attach furnace to overhead supply duct. See Figure 16.
Through-the-Floor Return Air System (Ducted)
IMPORTANT NOTES s 0ROPER LINE VOLTAGE POLARITY MUST BE MAINTAINED for the control system to operate correctly. Verify the incoming neutral line is connected to the white wire and the incoming hot line is connected to the BLACK WIRE 4HE FURNACE WILL NOT OPERATE UNLESS THE polarity and ground are properly connected.
Line Voltage Wiring
s %LECTRICAL CONNECTIONS MUST BE IN COMPLIANCE WITH ALL applicable local codes and the current revision of the National Electric Code (ANSI/NFPA 70). s &OR #ANADIAN INSTALLATIONS THE ELECTRICAL CONNECTIONS and grounding shall comply with the current Canadian Electrical Code (CSA C22.1 and/or local codes).
s #OUPER TOUTE ALIMENTATION �LECTRIQUE AU gÊnÊrateur d’air chaud avant de prodÊder aux travaux d’entretein. s !U MOMENT DE L ENTRETIEN DES COMMANDES �TIQUETEZ TOUS LES lLS AVANT DE LES D�BRANCHER S’assurer de les raccorder correctement. s 3 ASSURER QUE L APPAREIL FONCTIONNE AD�QUATEMENT APR�S L ENTRETIEN
Un entretein incorrect pourrait entraÎner un fonctionnement dangereux de l’appareil, des BLESSURES GRAVES LA MORT OU DES DOMMAGES matÊriels
OPTIONAL SINGLE CIRCUIT ADAPTOR KIT
SUPPLY SERVICE WIRE CONNECTION WITH SINGLE CIRCUIT ADAPTOR KIT
14
3. Install listed cable connector(s) in opening(s). If metalsheathed conduit is used for incoming power line(s), provide an approved metal clamp on conduit and secure it in entrance knockout. 4. Insert supply service wire(s) through cable connector(s) and connect wires to circuit breakers (Figure 17 & Figure 18). NOTE: To install single-circuit kit, perform step 5. If single-circuit kit installation is not needed, go to step 6. 5. To install optional single-circuit kit: a. Loosen lugs at supply side of circuit breakers. b. Remove cover from single-circuit kit (if supplied). c. Insert metal buss bars of kit into lugs of circuit breaker. d. Tighten lugs securely (45 in.-lbs. recommended). 6. Connect service ground wire(s) to grounding lug(s) provided. One ground is required for each supply circuit used. See Figure 19 (page 16).
To avoid personal injury or property damage, make certain that the motor leads cannot come into contact with non-insulated metal components of the unit.
WARNING:
Power entrance for all models may be through the right side or through the bottom of the unit. 1. Remove right-hand control panel (when viewing in downow position). 2. Locate power supply knockouts in side of unit and in bottom of unit. Remove appropriate plug(s) or knockout opening applicable to selected wire size(s).
Connecting Supply Service Wires
s 4HE FURNACE IS DESIGNED TO BE CONTROLLED BY A 6!# thermostat. The thermostat’s wiring must comply with the current provisions of the NEC (ANSI/NFPA 70) and with applicable local codes having jurisdiction. s 4HE THERMOSTAT SHOULD BE MOUNTED ABOUT FEET above the oor on an inside wall. DO NOT install the thermostat on an outside wall or any other location where its operation may be adversely affected by radiant heat from ďŹ replaces, sunlight, or lighting ďŹ xtures, and convective heat from warm air registers or electrical appliances. Refer to the thermostat manufacturer’s instruction sheet for detailed mounting information. See Figure 22 (page 18) for typical thermostat connections. s &OR PROPER INDOOR BLOWER OPERATION AND TEMPERATURE rise, the E4 electric furnace requires that the system thermostat be conďŹ gured NOT to call for the indoor blower to operate in the heating mode. Refer to your speciďŹ c thermostat installation instructions for details on the heating mode indoor blower conďŹ guration. s 4HE % SERIES ELECTRIC FURNACES INCORPORATE AN integrated control. The thermostat’s 1st stage compressor signal, Y, must be connected to the YELLOW control wire at the furnace to enable the indoor blower off-delay in the cooling mode.
Thermostat / Low Voltage Connections
4O MINIMIZE PERSONAL INJURY THE FURNACE CABINET MUST HAVE AN UNINTERRUPTED OR UNBROKEN ELECTRICAL GROUND 4HE CONTROLS USED IN THIS FURNACE REQUIRE AN EARTH GROUND TO OPERATE PROPERLY !CCEPTABLE methods include electrical wire or conduit approved for ground service. Do not use gas piping as an electrical ground!
WARNING:
OFF
RISQUE DE CHOC ÉLECTRIQUE, D’INCENDIE OU D’EXPLOSION Le non-respect des avertissements de sÊcuritÊ pourrait entraÎner un fonctionnement DANGEREUX DE L APPAREIL DES BLESSURES GRAVES la mort ou des dommages matÊriels.
ON
60A
OFF
AVERTISSEMENT:
s "EFORE SERVICING DISCONNECT ALL ELECTRICAL power to furnace. s 7HEN SERVICING CONTROLS LABEL ALL WIRES PRIOR to disconnecting. Reconnect wires correctly. s 6ERIFY PROPER OPERATION AFTER SERVICING v
ON
60A
Figure 16. Over-the-Floor Return Air System with Upow Stand
Upflow Stand
Filter (one obtained from furnace)
OFF
Improper servicing could result in dangerous operation, serious injury, death or property damage.
CIRCUIT BREAKER WIRE ASSEMBLIES (FACTORY INSTALLED)
CIRCUIT BREAKER BRACKET
ON 60A
It is recommended that the line voltage (240 VAC) to Figure 17. Optional Single Circuit Adaptor Kit the furnace be supplied from a dedicated branch circuit containing the correct fuse or circuit breaker for the furnace. CIRCUIT BREAKER For minimum circuit ampacity and maximum over-current BRACKET protection, see Table 6. See unit wiring diagrams (Figure CIRCUIT BREAKER 23, Figure 24, Figure 25, & Figure 26) for wiring details. WIRE ASSEMBLIES (FACTORY INSTALLED) Electrical components are shown in Figure 19 (page 16). Supply circuit requirements are listed below: SUPPLY SERVICE WIRE s MODEL IS FACTORY WIRED FOR SINGLE BRANCH SUPPLY CONNECTION WITHOUT SINGLE CIRCUIT ADAPTOR KIT circuit only. s MODELS ARE FACTORY WIRED FOR SINGLE BRANCH SUPPLY Figure 18. Installation of Supply Service Wires circuit (single-circuit kit factory installed). Dual-branch circuit can be used by removing factory-installed Grounding single-circuit kit. See Figure 17. s AND MODELS ARE FACTORY WIRED FOR dual-branch supply circuit. Single-branch circuit can be used by installing optional single-circuit kit.
s #IRCUIT BREAKERS INSTALLED IN THIS UNIT PROVIDE SHORT circuit protection of the internal wiring and serve as A DISCONNECT 4HE CIRCUIT BREAKERS $/ ./4 PROVIDE over-current protection of the supply wiring and may BE SIZED LARGER THAN THE BRANCH CIRCUIT PROTECTION Overcurrent protection of the supply wiring is PROVIDED BY THE BREAKER IN THE DISTRIBUTION PANEL AND MUST BE SIZED AS SHOWN IN Table 6 (page 19). OFF
ELECTRICAL SHOCK, FIRE OR EXPLOSION HAZARD Failure to follow safety warnings exactly could result in serious injury or property damage.
WARNING:
ELECTRICAL WIRING ON 60A
Furnace
Upflow Duct Connector
Misc Interior
17kw and 20kw Furnace
MI-25
4/2017
PIN 2
PIN 3
Blue
Black
High
PIN 4
High
#4
Med.-High
High
#2
#3
#4
1,790
1,620
1,320
990
CFM
1,460
1,310
1,170
880
CFM
-
-
PIN 5
s For New Heating Speed: Remove heating blower lead from HEAT on the control board. Choose desired speed and install new blower lead on that terminal. s For New Cooling Speed: Remove cooling blower lead from COOL on the control board. Install new blower lead on that terminal. s Same Speed, Heating & A/C: Install white jumper wire (supplied with unit) between HEAT & COOL of the control board. See Table 4 for blower performance data.
The selected heating blower lead is attached to HEAT on the control board. The selected cooling blower lead is attached to COOL on the control board.
NOTE TO INSTALLER When the unit is installed, the heating and cooling SPEEDS MUST BE SET FOR THAT PARTICULAR INSTALLATION 4HE INSTALLER IS RESPONSIBLE FOR SETTING THESE SPEEDS
#HANGING "LOWER 3PEED
See Table 3 (page 15) for blower speed as set by blower leads. Since the blower leads connect to the control box, blower speed selection is through use of the proper color-coded blower lead located inside the control box. The speed(s) set by the factory may be different from that shown on the wiring diagrams. See the unit control box for factory set blower speed(s).
3ELECTING "LOWER 3PEED
4ABLE "LOWER 0ERFORMANCE
Low
Med.-Low
#1
SPEED
PIN NO.
4/. ",/7%2 7)4( #/), !.$ COIL FILTERS, @ 0.3" ESP
Med.-Low
Med.-High
#3
Low
#1
#2
SPEED
PIN NO.
4/. ",/7%2 7)4( #/), !.$ COIL AND FILTERS, @ 0.3" ESP
4ABLE &URNACE "LOWER 3PEED $ATA
Yellow
Low Med-LO Med-Hi
PIN 1
CONTROL BOX BLOWER LEAD Red
4 SPEED BLOWER
PLUG / RECEPTACLE POSITION
1. Reinstall control box cover(s). 2. Switch circuit breaker(s) to the ON position. 3. Replace outer furnace door. 4. Check all duct connections and tape for air leakage.
Start-up Procedures
— Verify the polarity of the connections are correct, the line voltage power leads are securely connected and the furnace is properly grounded. Refer to the appropriate wiring diagram. — Verify the thermostat wires are securely connected to the correct leads on the terminal strip of the circuit board. — Check blower motor connectors for proper connection.
START-UP & ADJUSTMENTS Pre-Start Check List
NOTE: Installation of a ďŹ ve-wire thermostat circuit is recommended to for future addition of a heat/cool thermostat. See Figure 22 (page 18) for various E4 thermostat connections. 1. Install the 24V control-circuit cable through plastic bushing at either side of furnace. 2. Route control circuit wiring to wall thermostat and outdoor section, if installed. 3. Set anticipator to the setting listed in the thermostat’s installation instructions.
Installing Control Circuit Wiring
1. Turn off all electrical supply circuits to the furnace at the main service panel. 2. Remove furnace front door and switch furnace circuit breaker(s) to OFF. 3. Disconnect the motor plug from the control panel receptacle. 4. Remove one screw from left side of blower and three screws from right side of blower. Slide blower forward to remove. 5. Install new blower. NOTE: Make sure the side anges engage under side mounting tabs. Three tabs on one side and one on the other. The long tab is in the rear. 6. Replace screws removed from blower in step 4. 7. Connect the motor plug to the control panel receptacle. 8. Switch circuit breaker(s) to ON. 9. Reinstall furnace front door and turn on electrical supply circuits to the furnace.
"LOWER )NSTALLATION
28
16
9
21
29
30
29
11
30
4
3
13
18
22
17
7
12
20
14
19
5
28
Figure 19. E4 Furnace Components
10
6
15
16
27
5 Ton Blower
27
&)'52%3 4!",%3
25
26
2
24
1
Misc Interior
17kw and 20kw Furnace
MI-26
4/2017
LEFT SIDE
2�
3 3/4�
16 1/2�
T-Stat (Ă˜ 5/8â€?)
12 5/16�
BOTTOM VIEW
Optional Electric Ă˜ 1â€?
Optional Electric Ă˜ 5/8â€?
2 1/4� 2 5/16�
4 3/8� 14 7/8�
6�
17� 24 3/4�
BOTTOM VIEW
17 3/8�
FRONT VIEW
19 7/8�
TOP VIEW
13 1/2�
20�
Ă˜ 2â€?
T-Stat (Ă˜ 5/8â€?)
Figure 21. E4 Furnace Upow Stand Dimensions
16 1/2�
LEFT SIDE
20�
FRONT VIEW
VentilAire Knockout (1 1/2� X 5�)
Figure 20. E4 Furnace Physical Dimensions
11 3/4�
A.C. & H.P. Knockout (4 1/4� X 3 3/4�)
Tie- Down Tab
VentilAire Knockout (1 1/8� X 4 1/2�)
17�
RIGHT SIDE
1 3/8�
Electric Ă˜ 1 1/8â€?
Ă˜ 1 1/8â€?
Ă˜ 7/8â€?
RIGHT SIDE
24 1/2�
29�
Y RC
RED
W
R
G
UNSTRIPPED WIRES
2-WIRE THERMOSTAT
TO A/C
WIRE NUTS
WATTS (TOTAL KW, HEATING ELEMENTS & BLOWER)
010H
012H
W2
C
E
017H
16.6
57,000
3 (16.2) 10.5� Dia, 8� W
TO A/C
O
020H
20.4
70,000
4 (20.0)
4 (21.6)
2.0 - 5.0 Ton
4 Spd, 3/4HP, 3.8 Amps
10.5� Dia, 11" Dia., 8" W 8� W
4 (21.6)
22.0
75,000
023H 5-TON
4ABLE Unit SpeciďŹ cations
1. Heating output rated at listed voltage. For outputs at voltages other than 240V, multiply Btuh rating by the following factors: x 0.92 (230V), x 0.84 (220V), x 0.75 (208V). 2. Height is 56� with return air grille installed, 58� with coil cabinet and 72� with coil cabinet and upow stand. 3. The factory installed blower can be replaced with a multi-speed blower allowing the units to accept up to 5 tons of air conditioning.
NOTES:
Width-20" (508mm), Height-29" (737mm) (see note 2), Depth-24 1/2" (623mm)
10.5� Dia, 8� W
22.0
75,000
023H
TO H/P
FURNACE DIMENSIONS
2.0 - 4.0 Ton
2.0 - 4.0 Ton (See Note 3)
0.3
4 Speed, 1/3 HP, 2.9
10.5� Dia, 8� W
3 (15.0)
Y
TO E4EB FURNACE CONTROL WIRING
R
HEAT PUMP THERMOSTAT
240 Volts/60Hz/1-Phase
15.4
G
18" x 20" x 1" (nominal)
WITH FACTORY
WITH FACTORY
015H 53,000
R
AIR FILTER (STANDARD)
INSTALLED BLOWER
OPTIONAL HEAT PUMP AVAILABLE
INSTALLED BLOWER
OPTIONAL COOLING AVAILABLE
TEST ESP, IN. W.C. MAX
MOTOR SPEED, H.P. RATING, AMPS
2 (11.6) 10.5� Dia, 8� W
2 (10.0) 10.5� Dia, 8� W
HEATING ELEMENTS, NO. (TOTAL KW)
12.0
41,000
BLOWER WHEEL SIZE
10.4
35,000
Y
TO E4EB FURNACE CONTROL WIRING
G
WIRE NUTS
W
4-WIRE THERMOSTAT
Figure 22. % %" 4HERMOSTAT #ONNECTION
TO E4EB FURNACE CONTROL WIRING
RATED HEATING OUTPUT, BTUH (SEE NOTE 1) SUPPLY VOLTAGE
RH
TO E4EB FURNACE CONTROL WIRING
WHITE
&52.!#% -/$%,3 % %"
WIRE NUTS
WIRE NUTS YELLOW WHITE
GREY
5-WIRE THERMOSTAT
GREEN
GREY RED
GREEN
Electrical Data
RED
W
GREY
YELLOW GREY
TOP VIEW
YELLOW
WHITE WHITE
GREEN GREEN
RED YELLOW
13 1/2�
Misc Interior
17kw and 20kw Furnace
MI-27
4/2017
Misc Interior MODEL .5-"%2 % %" 010H
012H
015H
017H
020H
023H
SUPPLY CIRCUIT
MAXIMUM OVERCURRENT RATING
TOTAL AMPERES
MINIMUM CIRCUIT AMPACITY
Single
44.6
60
56
Single
51.2
70
64
Dual "A"
27.1
40
34
Dual "B"
24.2
30
30
Single
65.4
90
82
Dual "A"
44.6
60
56
Dual "B"
20.8
30
26
Single
70.4
90
88
2-Wire system maximum wire lengths: 24 Ga. = 55' 22 Ga. = 90' 20 Ga. = 140' 18 Ga. = 225'
Dual "A"
47.9
60
60
Dual "B"
22.5
30
28
Single
86.2
125
108
Dual "A"
44.6
60
56
Dual "B"
41.7
60
52
Single
93.8
125
117
Dual "A"
45.5
60
57
Dual "B"
48.0
60
60
17kw and 20kw Furnace
LOW VOLTAGE THERMOSTAT WIRE SIZE
4 or more wire systems maximum wire lengths: 24 Ga. = 25' 22 Ga. = 45' 20 Ga. = 70' 18 Ga = 110'
NOTE: Wire size must be in accordance to the applicable revision of the NEC and all other applicable codes.
4ABLE E4 Electrical SpeciďŹ cations
WIRING DIAGRAM Model: 10 KW Electric Furnace
AVERTISSEMENT
NOTES:
Switch circuit breakers to the “off� position before servicing the furnace.
Placez les disjoncteurs en position  off  avant d’entretenir la fournaise.
1. Supply wire size must be in accordance to the applicable revision of the NEC and all other applicable codes. 2. To change blower speed refer to installation instructions. 3. Refer to furnace installation instructions for thermostat connections. 4. If any wire in this unit is to be replaced it must be replaced with 105° C thermoplastic copper wire of the same gauge. 5. Not suitable for use on systems exceeding 120V to ground. 6. Refer to installation instructions for complete wiring diagram. 7. Heating and cooling may be wired on the same speed using the provided jumper wire.
GRAY C
AC RELAY ORANGE
L
RED
GRAY
GREEN
R
C
1 2 3 4 5 6
GRAY
WHITE
YELLOW
BLUE
COM
AC RELAY
“CIRCUIT A� RED
NO
ORANGE
BLACK
BLUE
1 2 3 4 5 6 RED
YELLOW
24V
BLACK
RED
WHITE
230V
10-WHITE-11(17) NOT ATTACHED.
RED
BLACK
H
MH
ML
NO
Wiring Diagrams
Figure 23. % %" ( -ODELS
WHITE
1. La taille du câblage d’alimentation doit être conforme à la rÊvision applicable des codes NEC et des autres codes applicables. 2. Pour changer la vitesse du ventilateur consultez les instructions d’installation. 3. Consultez les instructions d’installation de la fournaise pour les branchements du thermostat. 4. Si l’un ou l’autre des fils de cette unitÊ requiert un remplacement, il doit être remplacÊ par un fil en cuivre thermoplastique 105 °C du même gabarit. 5. Ne convient pas à l’utilisation sur les systèmes qui excèdent 120 V à la terre. 6. Consultez les instructions d’installation pour un schÊma de câblage complet. 7. Le chauffage et la climatisation peuvent être câblÊs sur la même vitesse à l’aide du cavalier fourni.
RED WHITE
COM
BLACK
BLACK
HEAT
COOL
L1
RED
NO
COM
DC RELAY
ELEMENT
BLACK
LEGEND: FIELD WIRING LOW VOLTAGE HIGH VOLTAGE
NO
COM
LIMIT 4
2
3
1
RED
GRAY
CONTROL BOARD
BLACK
GRAY ORANGE
BLUE
WHITE
HEATER
GC W
R
DC RELAY
GRAY
Y
YELLOW
L2
L1
EAC
RED
L2
RED ELEMENT
10139410 04/16 BLACK
MI-28
4/2017
Misc Interior 17kw and 20kw Furnace WIRING DIAGRAM Model: 12 KW Electric Furnace
AVERTISSEMENT
NOTES:
Switch circuit breakers to the “off” position before servicing the furnace.
Placez les disjoncteurs en position « off » avant d’entretenir la fournaise.
1. Supply wire size must be in accordance to the applicable revision of the NEC and all other applicable codes. 2. To change blower speed refer to installation instructions 3. Refer to furnace installation instructions for thermostat connections. 4. If any wire in this unit is to be replaced it must be replaced with 105° C thermoplastic copper wire of the same gauge. 5. Not suitable for use on systems exceeding 120V to ground. 6. Refer to installation instructions for complete wiring diagram. 7. Heating and cooling may be wired on the same speed using the provided jumper wire.
GRAY WHITE
Figure 24. % %" ( -ODELS
NO
“CIRCUIT B”
COM
ML
L
ORANGE
C
AC RELAY
1. La taille du câblage d’alimentation doit être conforme à la révision applicable des codes NEC et des autres codes applicables. 2. Pour changer la vitesse du ventilateur, consultez les instructions d’installation. 3. Consultez les instructions d’installation de la fournaise pour les branchements du thermostat. 4. Si l’un ou l’autre des fils de cette unité requiert un remplacement, il doit être remplacé par un fil en cuivre thermoplastique 105 °C du même gabarit. 5. Ne convient pas à l’utilisation sur les systèmes qui excèdent 120 V à la terre. 6. Consultez les instructions d’installation pour un schéma de câblage complet. 7. Le chauffage et la climatisation peuvent être câblés sur la même vitesse à l’aide du cavalier fourni.
WHITE
BLUE
1 2 3 4 5 6
CIRCUIT BREAKER
NO
ORANGE
BLACK
BLUE
1 2 3 4 5 6 RED
YELLOW
BLACK
BLACK
AC RELAY
COM
“CIRCUIT A”
RED WHITE
GRAY
RED
24V
10-WHITE-11(17) NOT ATTACHED.
WHITE
GREEN
230V
GRAY
YELLOW
MH H BLACK RED
RED
RED
BLACK BLACK RED RED
HEAT
EAC
COOL
L1
L2
L2
NO
COM
ELEMENT LIMIT
BLUE
CONTROL BOARD
LEGEND:
BLACK
GRAY ORANGE
HEATER
WHITE
Y
W
GC
R
DC RELAY
GRAY
GRAY
C
L1
YELLOW
CIRCUIT BREAKER R
DC RELAY
RED
BLACK NO
FIELD WIRING LOW VOLTAGE HIGH VOLTAGE
4
2
3
1
RED
COM
ELEMENT
10139420 04/16
21
22
WIRING DIAGRAM Model: 15 KW and 17 KW Electric Furnace NOTES:
AVERTISSEMENT Switch circuit breakers to the “off” position before servicing the furnace.
Placez les disjoncteurs en position « off » avant d’entretenir la fournaise.
1. Supply wire size must be in accordance to the applicable revision of the NEC and all other applicable codes. 2. To change blower speed refer to installation instructions 3. Refer to furnace installation instructions for thermostat connections. 4. If any wire in this unit is to be replaced it must be replaced with 105° C thermoplastic copper wire of the same gauge. 5. Not suitable for use on systems exceeding 120V to ground. 6. Refer to installation instructions for complete wiring diagram. 7. Heating and cooling may be wired on the same speed using the provided jumper wire.
NO
COM
AC RELAY
“CIRCUIT B”
YELLOW
BLUE
COM
GRAY
WHITE
1 2 3 4 5 6
CIRCUIT BREAKER
ORANGE
BLACK
RED
BLUE
YELLOW
1 2 3 4 5 6
AC RELAY
NO
“CIRCUIT A”
COM
WHITE RED RED BLACK BLACK
GRAY
RED
10-WHITE-11(17) NOT ATTACHED.
WHITE BLACK
GREEN
24V
RED
GRAY NO
BLACK
RED
BLACK
RED
H
MH
ML
L
ORANGE
WHITE
RED
C
AC RELAY
230V
BLACK CIRCUIT BREAKER
L1
RED
HEAT
L2
EAC
C
COOL
R
L1
RED
L2
YELLOW
LIMIT
BLACK
DC RELAY
RED
4
2
3
1
FIELD WIRING LOW VOLTAGE HIGH VOLTAGE
CONTROL BOARD
NO
RED
BLACK
COM
GRAY
ELEMENT
DC RELAY
BLACK LIMIT
DC RELAY
BLUE
WHITE
GRAY ORANGE
YELLOW
LEGEND:
GRAY
HEATER
W
GC
R
ELEMENT
Y
Figure 25. % %" ( % %" ( -ODELS
GRAY WHITE
1. La taille du câblage d’alimentation doit être conforme à la révision applicable des codes NEC et des autres codes applicables. 2. Pour changer la vitesse du ventilateur , consultez les instructions d’installation. 3. Consultez les instructions d’installation de la fournaise pour les branchements du thermostat. 4. Si l’un ou l’autre des fils de cette unité requiert un remplacement, il doit être remplacé par un fil en cuivre thermoplastique 105 °C du même gabarit. 5. Ne convient pas à l’utilisation sur les systèmes qui excèdent 120 V à la terre. 6. Consultez les instructions d’installation pour un schéma de câblage complet. 7. Le chauffage et la climatisation peuvent être câblés sur la même vitesse à l’aide du cavalier fourni.
NO NO
COM
COM
RED GRAY
4
2
3
1
ELEMENT
10139430 04/16
MI-29
4/2017
Misc Interior 17kw and 20kw Furnace WIRING DIAGRAM Model: 20 KW and 23 KW Electric Furnace
AVERTISSEMENT
NOTES:
Switch circuit breakers to the “off” position before servicing the furnace.
Placez les disjoncteurs en position « off » avant d’entretenir la fournaise.
1. Supply wire size must be in accordance to the applicable revision of the NEC and all other applicable codes. 2. To change blower speed refer to installation instructions 3. Refer to furnace installation instructions for thermostat connections. 4. If any wire in this unit is to be replaced it must be replaced with 105° C thermoplastic copper wire of the same gauge. 5. Not suitable for use on systems exceeding 120V to ground. 6. Refer to installation instructions for complete wiring diagram. 7. Heating and cooling may be wired on the same speed using the provided jumper wire.
C
“CIRCUIT B”
GRAY
BLACK BLACK
COM
CIRCUIT BREAKER
AC RELAY
COM
BLACK BLACK BLACK
4
2
3
1
CIRCUIT BREAKER
ELEMENT
RED HEAT
COOL
L1
L1
RED RED
R
CONTROL BOARD
GRAY ORANGE BLUE
Y
WHITE
HEATER
GRAY
GC
LIMIT
RED NO
ELEMENT
DC RELAY
W
“CIRCUIT A”
RED
WHITE
RED L2
EAC
C
L2
R
RED
RED RED
GRAY
WHITE
1 2 3 4 5 6
1 2 3 BLUE 4 BLACK 5 ORANGE 6 RED
YELLOW
10-WHITE-11(17) NOT ATTACHED
WHITE BLACK
GRAY
AC RELAY
NO
COM
COM
RED
WHITE
L
ORANGE
ML BLUE
YELLOW
MH
NO
NO
RED
BLACK
AC RELAY
GRAY
RED
24V
AC RELAY
WHITE
H
RED GREEN
230V
YELLOW
Figure 26. % %" ( % %" ( -ODELS
GRAY WHITE
1. La taille du câblage d’alimentation doit être conforme à la révision applicable des codes NEC et des autres codes applicables. 2. Pour changer la vitesse du ventilateur, consultez les instructions d’installation. 3. Consultez les instructions d’installation de la fournaise pour les branchements du thermostat. 4. Si l’un ou l’autre des fils de cette unité requiert un remplacement, il doit être remplacé par un fil en cuivre thermoplastique 105 °C du même gabarit. 5. Ne convient pas à l’utilisation sur les systèmes qui excèdent 120 V à la terre. 6. Consultez les instructions d’installation pour un schéma de câblage complet. 7. Le chauffage et la climatisation peuvent être câblés sur la même vitesse à l’aide du cavalier fourni.
NO
COM
DC RELAY
DC RELAY
BLACK
NO
GRAY
COM
LIMIT
NO
COM
BLACK NO
GRAY YELLOW
2
3
1
ELEMENT DC RELAY
LEGEND: FIELD WIRING LOW VOLTAGE HIGH VOLTAGE
4
RED
BLACK
COM
ELEMENT
BLACK
RED
10139440 04/16
GRAY
BROWN
23
INSTALLATION / PERFORMANCE CHECK LIST ELECTRICAL SYSTEM
INSTALLER NAME: CITY:
STATE:
ELECTRICAL CONNECTIONS TIGHT?
YES
NO
LINE VOLTAGE POLARITY CORRECT?
YES
NO
Supply Voltage: ................................................................ VOLTS INSTALLATION ADDRESS: CITY:
STATE:
UNIT MODEL #
YES
NO
IS THE THERMOSTAT LEVEL?
YES
NO
IS THE FURNACE GROUNDED PROPERLY?
YES
NO
IS THE HEAT ANTICIPATOR SETTING CORRECT?
YES
NO
#/-"534)/. !)2 6%.4).' 3934%-
UNIT SERIAL # MINIMUM CLEARANCES Table 1 (page 5)?
HAS THE THERMOSTAT BEEN CALIBRATED?
AS SHOWNI N
HAS
THE OWNER’S INFORMATION BEEN
HAS
THE LITERATURE PACKAGE BEEN
REVIEWED WITH THE HOME-OWNER? LEFT NEAR THE FURNACE?
YES
NO
IS THERE ADEQUATE FRESH AIR SUPPLY FOR VENTILATION?
YES
NO
FILTER(S) SECURED IN PLACE?
YES
NO
FILTER(S) CLEAN?
YES
NO
YES
YES
NO
NO
PROPOSITION 65 WARNING: ATTENTION INSTALLERS: It is your responsibility to know this product better than your customer. This includes being able to install the product according to strict safety guidelines and instructing the customer on how to operate and maintain the equipment for the life of the product. Safety should always be the deciding factor when installing this product and using common sense plays an important role as well. Pay attention to all safety warnings and any other special notes highlighted in the manual. Improper installation of the furnace or failure to follow safety warnings could result in serious injury, death, or property damage.
WARNING:This product contains chemicals known to the state of California to cause cancer. WARNING:This product contains chemicals known TO THE STATE OF #ALIFORNIA TO CAUSE BIRTH DEFECTS OR other reproductive harm.
These instructions are primarily intended to assist qualified individuals experienced in the proper installation of this appliance. Some local codes require licensed installation/service personnel for this type of equipment. Please read all instructions carefully before starting the installation. Return these instructions to the customer’s package for future reference.
MI-30
4/2017