SCREENING EFFICIENCY
Jef McGee New Business Manager- Aggregate
What is Screen Efficiency? A measure of how much of the feed material should have gone through the hole versus how much really did go through the hole. VSMA Handbook Definition:
Efficiency =
TPH of undersize in feed which actually passes TPH of undersize in feed (should pass)
Undersize
Oversize
Calculating Screen Efficiency Efficiency of the 1” cut on the top deck – The wrong way Most Commonly Made Mistake 41.1% of the deck overs passes 1”, so: 100% - 41.1% = 58.9% of deck overs did pass 1” Top Deck Has a 58.9% Screening Efficiency
Calculating Screen Efficiency Efficiency of the 1” cut on the top deck
How many TPH should go through? 93.8% passes 1”, so:
Feed Gradation
TPH (-1”) = 0.938 x 500 TPH TPH (-1”) = 469 TPH
TPH of Undersize in feed which actually passes Efficiency =
TPH of Undersize in feed (should pass)
Calculating Screen Efficiency Efficiency of the 1” cut on the top deck
How many TPH didn’t go through? 41.1% of the deck overs passes 1”, so: TPH (-1”) Overs = 0.411 x 53 TPH TPH (-1”) Overs = 22 TPH
Deck Overs Gradation
TPH of Undersize in feed which actually passes Efficiency =
TPH of Undersize in feed (should pass)
Calculating Screen Efficiency Efficiency of the 1” cut on the top deck
Feed Gradation
TPH of Undersize in feed which actually passes
Efficiency =
Deck Overs Gradation
= Total 1” minus - 1” minus that didn’t pass = 469 TPH total – 22 TPH that didn’t pass = 447 TPH actually passed
TPH of Undersize in feed which actually passes TPH of Undersize in feed (should pass)
=
447 TPH 469 TPH
=
95.3%
Factors Effecting Screen Efficiency Particle Size
Near sized particles are much harder to pass
1/2” / 1” = 0.50
1/2” Particle
4 holes
3/4” /1” = 0.75
3/4” Particle
18 holes
7/8” /1” = 0.875
7/8” Particle
95 holes
Factors Effecting Screen Efficiency Particle Shape
Flat or elongated material doesn’t pass easily
Factors Effecting Screen Efficiency Plugging and Blinding
Moisture Clays and silts Screen set-up (speed-stroke) Flat and elongated
Factors Effecting Screen Efficiency Feed Rate and Bed Depth
Less than 4:1 ratio of bed depth to aperture size at the discharge end of the deck Too lightly loaded decks reduce efficiency