TRAINING GUIDE TABLE OF CONTENTS
CHAPTER III: TRAINING COURSE “SYSTEM TECH. - SETUP”
READING AND UNDERSTANDING: The Powerplan The Dataplan Multiple displays
POWER “PLAN” o Production documents enveloppe o TELEGRAM GROUP ➟ command: ZIP
READING & UNDERSTANDING THE POWERPLAN o Main power cables (hartings) must be labelled according to the power-plan (letter and a number (ex : A1, B2 , C3 )
o “LETTER” is found on the right bottom, number states the order in which they are marked on the plan. o ➟ ATTENTION! Channel order must be respected in case one of the panels needs a power reset.
READING & UNDERSTANDING THE POWERPLAN o DIRECTION FOR CABLING o ALL IMPORTANT INFORMATION
MAXIMUM POWER IS IN AMP / PHASE
Project – LED Type – Quantity - …
o PLAN IS ALWAYS LOOKING FROM FRONT SIDE SCREEN !
READING & UNDERSTANDING THE POWERPLAN o TYPE OF POWER CABLE!
POCL POCL10 BO8 BO8L
➟ Harting loom to 8x Powercon ➟ Harting loom to 8x Powercon 10m ➟ Breakout schuko 8 channels ➟ Breakout schuko 8 channels + LINK etc...
READING & UNDERSTANDING THE POWERPLAN o
PLAN IS ALWAYS LOOKING FROM FRONT SIDE SCREEN !
POCL nr. 1
POCL nr. 2 2 ➟ CABLELOOM NR. 6 ➟ CHANNEL NR. 2x POCL
POWER CENTER ➟ LEFT/RIGHT POCL
NEXT PANEL
NEXT PANEL
POWER
NEXT ROW
POWER
POWER CENTER ➟ LEFT/RIGHT BO8L
OPTIONAL LINK
HARTING
NEXT PANEL
NEXT PANEL
POWER
NEXT ROW
POWER
POWER TOP ➟ DOWN N°4
N°3
N°2
N°1
POCL
NEXT PANEL
P O W E R
NEXT PANEL
NEXT PANEL
NEXT PANEL
NEXT PANEL
POWER TOP ➟ DOWN BO8L
HARTING OPTIONAL LINK
P O W E R
NEXT PANEL
NEXT PANEL
NEXT PANEL
NEXT PANEL
DATA “PLAN” o Production documents enveloppe o TELEGRAM GROUP ➟ command: ZIP
READING & UNDERSTANDING THE DATAPLAN o DATA : the main data lines (utp) must also be labelled according to the data plan (letter and a number (ex : A1, B2 , C3 )
o “LETTER” is found on the right bottom, number states the order in which they are marked on the plan. o Line number as found on the data-plan o Port number from the signal distributor o function of the cable (in for input , out for output) as the system is fully redundant after setup.
READING & UNDERSTANDING THE DATAPLAN o “LETTER” is found on the right bottom, number states the order in which they are marked on the plan. o Line number as found on the data-plan o Port number from the signal distributor o function of the cable (in for input , out for output) as the system is fully redundant after setup.
A 8 - 3 IN
READING & UNDERSTANDING THE DATAPLAN o PLAN IS ALWAYS LOOKING FROM FRONT SIDE SCREEN !
o DIRECTION FOR CABLING o ALL IMPORTANT INFORMATION
21 REEL FIRST INPUTS / RETURN LINES 0 open lines / special links 91 vertical link cables 212 Horizontal link cables 303 TOTAL link cables
READING & UNDERSTANDING THE DATAPLAN
o Information on the first inputs Line number Function INPUT (IN) / OUTPUT (OUT)
READING & UNDERSTANDING THE DATAPLAN o
PLAN IS ALWAYS LOOKING FROM FRONT SIDE SCREEN !
UTP nr. 1
UTP nr. 2 “OUT”
UTP 25/40/80/100 BACKSIDE LED !
READING & UNDERSTANDING THE DATAPLAN
o
PLAN IS ALWAYS LOOKING FROM FRONT SIDE SCREEN !
READING & UNDERSTANDING THE OVERVIEWPLAN
o
WEIGHT for each screen
o
POWER (AMP) for each screen
o
LED TYPE + SCREEN NR.
READING & UNDERSTANDING MAPPING PICTURES
SEND TEST IMAGE
READING & UNDERSTANDING MAPPING PICTURES
PHYSICAL PLANS always in DROPBOX & TELEGRAM PROJECT GROUP
SCHEMATIC 2 DISPLAYS POSSIBLE OPTION ON 4K PROCESSOR POWER
N°1
POCL POWER SUPPLY UNIT (PSU)
N°2
N°3
N°4
HARTING
VENUE POWER LINSN HUB
DATA HASPEL
DATA HASPEL
PIXELSCREEN LAPTOP (RGB TEST)
DATA (HDMI) BACK – UP LINE 2 USB CABLE
PROCESSOR 4K
DISPLAY 2
BACK – UP LINE 1 DISPLAY 1