WOOD FLOORING INSTALL GUIDE FOR NORTHERN WIDE PLANK HARDWAX OIL FINISHED TWO-LAYER MAGNETIZED WOOD FLOORS OVER STEEL-TOPPED RAISED ACCESS FLOORING (RAF) SYSTEMS
1 / INTRODUCTION NORTHERN WIDE PLANK TWO-LAYER MAGNETIC ENGINEERED WOOD FLOORING IS DESIGNED FOR INSTALLATION OVER STEEL-TOPPED RAISED ACCESS FLOORING (RAF) SYSTEMS. THE MAGNETIC BACKING PROVIDES SECURE HOLDDOWN WITHOUT ADHESIVES OR FASTENERS, WHILE THE MODIFIED TONGUE-ANDGROOVE PROFILE ENSURES PROPER-ALIGNMENT AND STABILITY. IMPORTANT: PLEASE READ AND UNDERSTAND THIS INFORMATION COMPLETELY PRIOR TO INSTALLATION.
2 / JOBSITE INSPECTION & PREPARATION ENVIRONMENTAL REQUIREMENTS MAINTAIN THE FOLLOWING CONDITIONS BEFORE, DURING, AND AFTER INSTALLATION, AS REQUIRED BY THE MAGNETIC WARRANTY: • • • •
TEMPERATURE: 60ºF TO 77ºF (15℃ TO 25℃). RELATIVE HUMIDITY: 25% TO 65% RH. SURFACE/WOOD TEMPERATURE: MUST NOT EXCEED 85ºF (29℃). TEMPERATURE FLUCTUATION: MUST NOT CHANGE MORE THAN 9ºF (5℃) WITHIN 24 HOURS.
IMPORTANT: THESE CONDITIONS MUST BE MAINTAINED CONTINUOUSLY. FAILURE TO DO SO VOIDS THE WARRANTY COVERAGE. JOBSITE READINESS • HVAC SYSTEMS MUST BE OPERATIONAL AND MAINTAINING REQUIRED CONDITIONS. • BUILDING ENVELOPE MUST BE SEALED.
1 NWP INSTALL GUIDE - TWO-LAYER MAGNETIZED WOOD FLOORS
DELIVERY INSPECTION AND STORAGE • • • • •
INSPECT ALL FLOORING UPON DELIVERY. CONFIRM CORRECT PRODUCT, COLOR, GRADE, AND QUANTITY. STORE FLOORING FLAT, FULLY WRAPPED, AND PROTECTED FROM MOISTURE. DO NOT STORE DIRECTLY ON CONCRETE OR IN UNCONDITIONED SPACES. ACCLIMATION IS NOT REQUIRED IF ENVIRONMENTAL CONDITIONS MEET WARRANTY REQUIREMENTS.
RAISED ACCESS FLOOR (RAF) REQUIREMENTS • RAF SYSTEM MUST BE FULLY INSTALLED AND LEVEL. • RAF PANELS MUST BE STRUCTURALLY SOUND AND PROPERLY SEATED IN THEIR GRID. • CLEAN STEEL PANEL SURFACES THOROUGHLY. • STEEL TOP SHEETS MUST BE CLEAN AND FREE FROM OILS, DUST, DEBRIS, METAL SHAVINGS, OR CONTAMINANTS.
3 / INSTALLATION OF FLOORING OVER STEEL‑TOPPED RAISED ACCESS PANELS LAYOUT PLANNING ESTABLISH THE DESIRED LAYOUT AND ACCOUNT FOR RAF PANEL SEAMS. INSTALL SEVERAL STARTING ROWS PARALLEL TO THE LONGEST WALL AND CHECK FOR STRAIGHTNESS AND ANY GAPS BETWEEN PLANKS. BOARD INSPECTION INSPECT EACH PLANK DURING INSTALLATION. NATURAL WOOD VARIATION IS EXPECTED. DO NOT INSTALL BOARDS WITH VISIBLE DEFECTS OR STRUCTURAL DEFICIENCIES. CONTINUE ON PAGE 3
2
SORT & RACKING SORT BOARDS BY LENGTH AND APPEARANCE TO ACHIEVE A BALANCED LAYOUT. RACK OUT SEVERAL ROWS PRIOR TO INSTALLATION TO CONFIRM PATTERN AND COLOR DISTRIBUTION. EXPANSION GAPS LEAVE A 1/4” (6 MM) EXPANSION GAP AT ALL VERTICAL SURFACES. DO NOT BLOCK EXPANSION WITH TRIM, FASTENERS, OR FIXTURES. CUTTING USE STANDARD WOOD FLOORING CUTTING TOOLS TO CUT BOARDS AND THE MAGNETIC BACKER. ENSURE CUT EDGES REMAIN CLEAN AND SQUARE. CONTINUE INSTALLATION • ALIGN SUBSEQUENT PLANKS USING THE MODIFIED TONGUE‑AND‑GROOVE PROFILE. • MAINTAIN STRAIGHT LINES AND CONSISTENT PRESSURE CHECKING FOR TIGHT JOINTS REGULARLY • TAP GENTLY WITH A SOFT MALLET TO ENSURE TIGHT JOINTS. • STAGGER END JOINTS A MINIMUM OF 12 INCHES (300 MM). • AVOID CLUSTERING SHORT BOARDS TOGETHER; USE THEM AT THE ENDS OF RUNS WHENEVER POSSIBLE. • ENSURE EACH PLANK MAKES FULL CONTACT WITH THE STEEL SURFACE. • UNUSED MATERIAL SHOULD BE LEFT WITH THE OWNER AND STORED IN A DRY PLACE IN CASE FUTURE REPAIRS ARE NEEDED. ACCESS PANEL FUNCTIONALITY MAGNETIC INSTALLATION PRESERVES FULL RAF ACCESSIBILITY. TO ACCESS UNDERFLOOR SYSTEMS, USE A HAND-OPERATED SUCTION CUP OR VACUUM LIFTER TO LIFT THE PLANKS FREE FROM THE STEEL TOP PANELS.
3 NWP INSTALL GUIDE - TWO-LAYER MAGNETIZED WOOD FLOORS
4 / REMOVAL & REINSTALLATION PROCESS REMOVAL THE REMOVAL PROCESS REQUIRES TWO ADJACENT FLOOR PLANKS TO BE REMOVED TOGETHER BECAUSE THE INTERLOCKING CONNECTION BETWEEN THE PLANKS. STEP 1 WHEN REMOVING THE PLANKS, IDENTIFY TWO ADJACENT PLANKS TO BE REMOVED. BEGIN AT THE CENTER OF THE TWO PLANKS, RATHER THAN TRYING TO LIFT FROM THE ENDS. CAREFULLY PULL/LIFT THE PLANKS UPWARD FROM THE CENTER TO DISENGAGE THE LOCKING MECHANISM. STEP 2 ONCE THE CENTER IS RELEASED, EASE THE PLANKS OUTWARD AND AWAY FROM THE SURROUNDING FLOOR, WORKING CAREFULLY ALONG THE JOINTS. THE RAF PANEL CAN THEN BE ACCESSED. REINSTALLATION WHEN REINSTALLING THE PLANKS, THE ABOVE NOTED PROCESS IS ESSENTIALLY REVERSED. STEP 1 POSITION THE TWO PLANKS TOGETHER AND ALIGN THEM WITH THE SURROUNDING FLOOR. ENGAGE THE EDGES/LOCKING MECHANISM, STARTING FROM THE OUTER EDGES. CAREFULLY WORK THE PLANKS DOWNWARD INTO PLACE UNTIL THE LOCKING SYSTEM IS FULLY ENGAGED. STEP 2 VERIFTY THAT THE JOINTS ARE TIGHT, LEVEL, AND PROPERLY ALIGNED WITH THE SURROUNDING FLOOR. IMPORTANT: THE PLANKS SHOULD NOT BE FORCED, BENT EXCESSIVELY, OR PRIED FROM ONE END, AS THIS CAN DAMAGE THE INTERLOCKING EDGES. THE CENTER-OUT REMOVAL AND RESERSE INSTALLATION PROCESS IS DESIGNED TO ALLOW THE PLANKS TO BE REMOVED AND REINSTALLED WHILE MAINTAINING THE INTEGRITY OF THE FLOOR SYSTEM. 4
5 / FLOOR PROTECTION DURING CONSTRUCTION AFTER INSTALLATION, VACUUM AND CLEAN THE FLOOR THOROUGHLY TO REMOVE ABRASIVE DEBRIS BEFORE COVERING IT WITH A FLOOR PROTECTION PRODUCT TO AVOID DAMAGE TO THE FLOOR. COVER THE FLOOR USING FLOOR PROTECTION AND HARDBOARD TO PROTECT THE FLOOR DURING FURTHER CONSTRUCTION WORK. ALWAYS COVER THE FLOOR COMPLETELY, SINCE SOME FLOORS ARE LIGHT-SENSITIVE AND UNCOVERED AREAS MAY CHANGE COLOR. OUR RECOMMENDED PRODUCT FOR FLOOR PROTECTION IS NWP PLANK LINER WHICH HAS A SELF-ADHESIVE BACKER ELIMINATING THE NEED FOR TAPE TO HOLD IT IN PLACE. DO NOT APPLY TAPE TO FINISHED FLOORING. ONCE ALL CONSTRUCTION WORK IS COMPLETE AND THE FLOOR PROTECTION COVERING IS REMOVED, PLEASE REFER TO THE CLEANING & CARE GUIDE FOR NORTHERN WIDE PLANK HARDWAX OIL FINISHED TWO-LAYER MAGNETIZED WOOD FLOOR FOR INITIAL AND REGULAR CARE & MAINTENANCE.
6 / FLOOR CARE & MAINTENANCE REFER TO THE CLEANING & CARE GUIDE FOR NORTHERN WIDE PLANK HARDWAX OIL FINISHED TWO-LAYER MAGNETIZED WOOD FLOOR FOR FULL INSTRUCTIONS.
5 NWP INSTALL GUIDE - TWO-LAYER MAGNETIZED WOOD FLOORS
CU RRE NT VER SI O N : SEPT EM B ER 1 , 2 0 2 6
5930 L L O YD TOWN / AUR O R A R O AD, SC H O M B E R G , O N 877/ 763/ 6169 I N F O @ N O R T H ER N WI DEPL AN K. C A NO RT H ER N WI D EP L A N K. C A