My new steam boiler bangs, clangs, and short cycles! What's wrong? Improper sizing of the "near-boiler piping" and/or the waterside of the boiler wasn't properly cleaned after installation. The problem is usually in the "near-boiler piping". A quick scan of boiler manufacturer piping diagrams reveals that a specific, well-thought-out arrangement of components in the near-boiler piping will ensure highest operating efficiency and greatest ease of commissioning and service. Can I install a setback thermostat myself? Usually, if you are sure that you're existing thermostats are low voltage (24 volt AC), and you do not have zone valves. High voltage thermostat (110 volt AC) circuits will usually burn out a modern chronotherm thermostat and can be a fire hazard. A chronotherm can be safely installed with the addition of a relay but should be left to the professionals. Some zone valves require special attention. When installing a modern chronotherm, ask a qualified electrician or your oil burner technician if your band of zone valves require any special attention. When is the best time to have the annual maintenance (Cleaning) on Oil Fired Heating Equipment? This depends on the type of system you have and the environment that it’s in. The old myth of getting the unit ready for the coming winter really is not true anymore (never was). It is generally better to have the unit serviced as soon as the heating season is over especially if you have AC.