Skip to main content

Level 05: Arts & Humanities Faculty Development – Clarendon Street (NTU City Campus)

Page 1

CJ G

ARTS & HUMANITIES FACULTY DEVELOPMENT - CLARENDON STREET, NTU CITY CAMPUS ESTATE. CRAIG J. GREGORY - ARCHITECTURAL TECHNOLOGY BSc. - YEAR 02 Nottingham Trent University approached several designers to accumulate their ideas for the newly proposed Arts & Humanities development, alongside the DICE building on Clarendon Street & the Waverley Terraces. This proposed design to was to inspire, create a centralised location & a gateway for the home of the NTU’s Arts & Humanities facility , within the city centre’s campus. As such, this design incorporated building materials that would benefit a sustainable & healthy working environment for the students. Implementing several aspects of:

BREEAM into the design The use of Sustainable materials during construction & its Building Life Cycle. A PassivHaus & Energy Efficient system installed. Natural methods of Energy production & Grey-water recycling. The reintegration of “Green-Areas” to the Urban environment.

LOCATION PLAN - Clarendon Street

South Facing Facade - Overlooking from DICE building

SITE PLAN - Arts & Humanities Department. Clarendon Street Facade & Bike Entrance

BREEAM Section

Credits Achieved

Biophilic SUDs System

Main Entrance

Biophilic SUDs System - At Night

Management 21 Health & Well 15 being Energy 16 Transport 11 Water 7 Materials 6 Waste 11 Land Use & 12 Ecology Pollution 12 Inovation 0 Final BREEAM Score Rooftop Garden / Breakout Space BREEAM Rating

Category weighting LectureSection Theatre Score (%) (Fully Fitted) 0.11 11.00

Credits Availble

% of credits achieved

21

100.00

20

75.00

0.14

10.50

31 12 9 14 11

51.61 91.67 77.78 42.86 100.00

0.16 0.10 0.07 0.15 0.06

8.26 9.17 5.44 6.43 6.00

13

92.31

0.13

12.00

12 15

100.00 0.00

0.08 8.00 0.10 0.00 76.80% Chaucer Street Entrance / Breakout Space Excellent

BREEAM SCORE 35

BREEAM Section

31

25 21 21

20

20 15

15

16 11

10

14

12 7

11 11

9

12

13

15 12 12

6

5

Wild Garden Rooftop

0

0

Credits Achieved

Management 21 Health & Well 15 being Energy 16 Transport 11 Water 7 Materials 6 Waste 11 Land Use & 12 Ecology Pollution 12 Inovation 0 Final BREEAM Score BREEAM Rating

Category Section weighting BREEAM Rating Score (%) (Fully Outstanding Fitted) Excellent 0.11 Very Good 11.00

Credits Availble

% of credits achieved

21

100.00

20

75.00

31 12 9 14 11

51.61 91.67 77.78 42.86 100.00

Good 0.14 10.50 Pass 0.16 Unclassified 8.26 0.10 9.17 0.07 5.44 0.15 6.43 0.06 6.00

13

92.31

0.13

12 15

100.00 0.00

0.08 8.00 0.10 0.00 76.80% Excellent

12.00

Credits Availble

BREEAM SCORE 35 31 30

NUMBER OF CREDITS

NUMBER OF CREDITS

30

Credits Achieved

25 21 21

20

20 15

15

16 11

10

14

12 7

11 11

9 6

5 0

Credits Achieved

Credits Availble

12

13

1


CJ G

ARTS & HUMANITIES FACULTY DEVELOPMENT - CLARENDON STREET, NTU CITY CAMPUS ESTATE. CRAIG J. GREGORY - ARCHITECTURAL TECHNOLOGY BSc. - YEAR 02

1300

1 200 x 200mm COURSE AGGREGATE BORDER BETWEEN VEGETATION LAYER & PARAPET. INTENSIVE (SEDUM) VEGETATION LAYER, MIN 150mm THK.

H-5

FILTER LAYER, TO ALLOW WATER DRAINAGE. 75mm THK COURSE-AGGREGATE TYPE DRAINAGE LAYER

4152

PROTECTIVE ROOT RESISTANT MEMBRANE LAYER 1000 GAUGE VISQUEEN WATERPROOF MEMBRANE LAYER, LAPPED WITH VAPOUR BARRIER AT PARAPET. 100mm THK KS THERMAROOF TR24 INSULATION BOARD, LAID ABOVE CONCRETE SUPERSTRUCTURE.

PLANT ROOM

1000 GAUGE VISQUEEN VAPOR BARRIER MEMBRANE, LAPPED OVER CONCRETE PARAPET. EXTERNAL WALL CONSTRUCITON: 1.

2No.1200 x 2400 x 12.5mm THK GYPSUM GLASROC F-FIRECASE & 1No.1200 x 2400 x 6mm THK GYPSUM GLASROC F-MULTIBOARD FIXED WITH 50mm GLASROC FIRECASE SCREWS TO WALL SYSTEM & BOARD JOINTS TO BE STAGGERED MIN OF 600mm BETWEEN ADJACENT SIDES. FIRE PROTECTION = 2.0 Hrs REPEATED ON EXTERNAL SIDE

PROPRIETY CEILING SYSTEM WITH, 100mm THK KS THERMAROOF TR24 INSULATION BOARD. 250mm THK CONCRETE SUPER STRUCTURE (ABLE TO SUPPORT 200 kg / m²) DESIGNED & SPECIFIED BY SE. TO BE BONDED WITH SUITABLE ANCHORAGE TO ISOHEMP-CONCRETE LINTEL

H-4

2.

300 x 600 x 300mm THK ISO-HEMP RC BLOCKWORK LINTEL, LAID WITH 10mm MORTAR JOINTS TO MANUFACTURE'S SPECIFICATION & LOADING TABLES AT ALL OPENINGS. 2.1. 44dB ACOUSTIC RATING 2.2. B FIRE RATING (WITHOUT RENDER - NF EN 13501-1)

DETAIL C - INTENSIVE (SEDIUM) GREEN ROOF CONNECTION SCALE 1:20

3.

300 x 600 x 150mm THK ISO-HEMP BLOCKWORK, LAID 10mm MORTAR JOINTS 3.1. 40dB ACOUSTIC RATING 3.2. B FIRE RATING (WITHOUT RENDER - NF EN 13501-1)

4.

140mm WIDE CLADDING RAIL SYSTEM @ 600mm C/C FIXED TO EXTERNAL ISOHEMP BLOCKWORK WITH SUITABLE FIXINGS, SUPPLIED BY KINGSPAN.

5.

50mm THK KS QUADCORE KARRIER PANEL, FIXED TO RAIL SYSTEM AS PER MANUFACTURE'S SPECIFICATION. 5.1. 24 dB ACOUSTIC RATING 5.2. AIR TIGHTNESS = 50 Pa (BS EN14509) 5.3. WATER TIGHTNESS = 600 Pa

6.

PASTORAL ROOM

450mm THK ISOHEMP BLOCKWORK WALL SYSTEM & INTERNAL FINISHES.

H-3

YELOFAN E STRIP ACUSTIC EDGE STRIP BY CELLECTA 200mm THK PCC HOLLOWCORE FLOORING SYSTEM MANUFACTURED BY CREAGH & RESTED UPON L-SHAPED PCC CONCRETE RINGBEAM, THEN BACKFILLED WITH INSITU CONCRETE FOR JOINTING OF FLOOR TO RINGBEAM. 150 x 32mm THK KS KOOLTHERM CAVITY CLOSER, FIXED BY WALL BRACKETS INTO MORTOR JOINT. (30 Mins FIRE PROTECTION)

32mm THK KS ALUMINUM CASSETTE RAINSCREEN CLADDING, FIXED TO KS QC PANEL. (SUBJECT TO CLIENTS CHOICE OF FINISH)

500 x 300mm THK REINFORCED PCC L-SHAPED RINGBEAM MANUFACTURED & SPECIFIED BY CREAGH CONCRETE SPECIALISTS, CONNECTED TO STRUCTURAL COLUMNS WITH INSITU BONDING METHODS, PRIOR TO FLOOR INSTALLATION.

INTERMEDIATE FLOOR BUILDUP: 1. 4. 5. 6. 7.

15mm THK LACQUERED SOLID WOOD T&G FLOORING 0.5 x 10m DEVI-COMFORT 150T UNDERFLOOR HEATING MAT SYSTEM TO BE PLACED UNDER SCREED, MANUFACTURED BY DANFOSS & LAID TO MANUFACTURE'S SPECIFICATION. Min 40mm THK EVENLY SPREAD SCREED LAYER. SUITABLE VAPOR MEMBRANE TO BE LAID & LAPPED AT EXTERNAL EDGES. 1200 x 5300 x 220mm THK PCC 220mm THK PCC HOLLOWCORE FLOORING SYSTEM MANUFACTURED BY CREAGH CONCRETE SOLUTIONS

TUTORS OFFICE

140mm WIDE CLADDING RAIL SYSTEM @ 600mm C/C FIXED TO EXTERNAL ISOHEMP BLOCKWORK WITH SUITABLE FIXINGS, SUPPLIED BY KINGSPAN. 32mm THK KS ALUMINUM CASSETTE RAINSCREEN CLADDING & 50mm THK KS QUADCORE KARRIER PANEL, FIXED TO RAIL SYSTEM AS PER MANUFACTURE'S SPECIFICATION.

H-2

SUSPENDED CEILING BUILDUP: 1. 2. 3. 4. 5. 6. 7.

3. 4. 5. 6. 7. 8. 9.

DETAIL B - EXT' WALL INTER' FLOOR CONNECTION

GYPFRAME MF8 STRAP HANGERS @ 1200mm C/C & FIXED TO MF7 WITH 2No. BRITISH GYPSUM WAFER HEAD JACK-POINT SCREWS. 75mm THK ISOVER 1200 APR INSULATION (5200625577) WHERE REQUIRED GYPFRAME MF6 PERIMETER CHANNEL SUITABLY FIXED TO WALL @ 600mm C/C GYPFRAME MF12 SOFFIT CLEAT FIXED TO HANGER WITH MF11 NUT & BOLT GYPFRAME MF7 PRIMARY SUPPORT CHANNELS @ 1200mm C/C. 2400mm GYPFRAME MF5 CEILING SECTIONS @ 600mm C/C FIXED TO EACH MF7 WITH 2No. BRITISH GYPSUM WAFER HEAD JACK-POINT SCREWS. 12.5mm GYPTONE QUATTRO 41 CEILING PANELS FIXED WITH 25mm DRYWALL SCREWS @ 230mm C/C.

SCALE 1:10

SUITABLE FRENCH-DRAIN SYSTEM.

TUTORS OFFICE

EXTERNAL ISOHEMP WALL & KS CLADDING SYSTEM. FLOOR BUILD SEE CONSTRUCTION NOTES DPM & VAPOR BARRIERS TO BE LAPPED OVER CONCRETE RING-BEAM & VERTICAL LAID DOWN EXTERNAL WALL BUILDUP.

H-1

GROUND FLOOR BUILDUP: 1. 2.

FOR PROPRIETARY CEILING DETAIL SEE CONSTRUCTION NOTES

15mm THK LACQUERED SOLID WOOD T&G FLOORING 0.5 x 10m DEVI-COMFORT 150T UNDERFLOOR HEATING MAT SYSTEM TO BE PLACED UNDER SCREED, MANUFACTURED BY DANFOSS & LAID TO MANUFACTURE'S SPECIFICATION. 50mm THK SCREED LAYER, LAID TO AN EVEN FINISH VISQUEEN VAPOR MEMBRANE TO BE LAID & LAPPED AT EXTERNAL EDGES 100mm THK KS THERMAFLOOR TF70 INSULATION. 125mm THK RC CONCRETE SLAB (DESIGNED BY PQE) 1000 GAUGE VISQUEEN POLYTHENE VAPOR BARRIER TURNED UP AT PERIMETER LAPPED WITH DPC. 25mm SANDBLINDING LAYER. MIN 150mm THK WELL COMPACTED HARDCORE LAYER

INSULATION IS TO BE LAID VERTICAL A MIN OF 150mm UP INTERNAL WALL TO PREVENT COLD-BRIDGING. 900 x 450mm THK PCC RC GROUND BEAM, DESIGNED & SPECIFIED BY CREAGH CONCRETE SPECIALISTS & INSTALLED TO MANUFACTURES SPECIFICATIONS. TO BE INTERCONNECTED WITH STRUCTURAL COLUMNS VIA STEELRODS & INSITU POUR. 1m x 1m x 0.9mm THK PCC PILECAP DESIGNED & SPECIFIED BY CREAGH CONCRETE SPECIALISTS & INSTALLED TO MANUFACTURES SPECIFICATIONS TO CONCRETE RINGBEAM

BIKE STORAGE ROOM

8400

INSITU POURED RC CONCRETE PILE TO BE DESIGNED & SPECIFIED BY SE & SUBJECT TO CHANGE DUE TO GROUND CONDITIONS.

DETAIL A - FOUNDATION CONNECTION SCALE 1:20

PERIMETER SECTION 01 SCALE 1:50

300x300mm REINFORCED CONCRETE COLUMN DESIGNED BY PQE & FIXED INTO FOUNDATIONS DURING CONSTRUCTION PROCESS & ENCASED IN 2No. 10mm THK GLASROC PLASTERBOARDS.

SEE EXTERNAL WALL CONSTRUCTION NOTES: 1&2 3&4

200mm THK PCC HOLLOWCORE FLOORING SYSTEM MANUFACTURED BY CREAGH & RESTED UPON L-SHAPED PCC CONCRETE RINGBEAM, THEN BACKFILLED WITH INSITU CONCRETE FOR JOINTING OF FLOOR TO RINGBEAM.

5 6 7

SEE SUSPENDED CEILING NOTES: 1 2 3

12 mm ROD USED FOR DIAGONAL TIES.

BRACING FOR WALL CLADDING ISOMETRIC DETAIL SCALE 1:20

4

SUSPENDED PROPRIETY CEILING SYSTEM ISOMETRIC DETAIL

SCALE 1:20

5&6


Turn static files into dynamic content formats.

Create a flipbook
Level 05: Arts & Humanities Faculty Development – Clarendon Street (NTU City Campus) by CJ Gregory. - Issuu