1 minute read
DETAIL 02 - SUSPENDED FLOOR TECHNICAL DETAIL
EASI-JOIST WALL HANGERS SECURED ONTO 140 x 50mm C16 TIMBER SOLEPLATE & FIXED TO FLOOR JOIST VIA GALVANIZED PRESS-STUD FIXINGS (TO MANUFACTURES SPECIFICATIONS)
15mm THK T&G FLOOR BOARDS, SECURED TO PANEL WITH C/S SCREWS
Advertisement
15mm THK OSB BOARD LAID OVER & SECURED TO FLOOR EASI-JOIST ROOF BEAMS WITH SUITABLE FIXINGS
Preliminary Client Approval Planning
X X X
Building Control Fire Precautions Pre-Tender
X X X
4000 x 195 x 97mm THK EASI-JOIST FLOOR BEAMS @ 600mm C/C (UNLESS OTHERWISE STATED)
120mm THK KINGSPAN KOOLTHERM (K70) INSULATED PANEL, PLACED INBWETWEEN TIMBER STUD FRAME.
12.5mm THK PLASTERBOARD, WITH 3mm PLASTER SKIM FINISH SECURED TO UNDERSIDE OF EASI-JOISTS.
2400 x 120 x 20mm THK TIMBER CLADDING SYSTEM (CLIENT'S ASTHETIC RECOMMENDATION) FIXED TO 25x25mm TIMBER BATTON RAILS BEFORE ATTACHED TO EXTERNAL OSB BOARD.
32.5mm THK KINGSPAN KOOLTHERM (K118) INSULATED PLASTERBOARD WITH PLASTER SKIM FINISHED, SECURED ONTO TIMBER FRAME WITH C/S SCREWS .
KINGSPAN NILVENT BREATHABLE MEMBRANE, FIXED ONTO INSULATED PLASTERBOARD.
140mm THK C16 TIMBER STUD PARTITION WALL SECURED WITH SUITABLE FIXINGS & LAID ONTOP OF 140x100mm TIMBER SOLEPLATE
1500 x 1200mm DOUBLE GLAZED WINDOW INSTALLED TO MANUFACTURES SPECIFICATION & SUPPLIED BY CRITTAL
10mm THK ADVENTEC OSB BOARD WITH DUPONT AIRGUARD REFLECTIVE VAPOUR BARRIER MEMBRANE SECURED ON WITH C/S SCREWS TO TIMBER STUD WALL.
SUSPENDED FLOOR CONNECTION DETAIL
A Revision Description
Mr A O'Roake
Mr R. Dundass 104 Arkwright Studio, Nottingham,
Nottinghamshire, England NG1 4BU Tel : 123456789
Coach House Extension
& Refurbishment.
Suspened Flr Technical Detail West Bridgeford, Nottingham