MATERIALS TO BE FURNISHED

CONTACT: LISA KOERNER PHONE: (217) 857 - 7193 EMAIL: lisak@stevensind.com

AND ADHESIVE

P.O. DRAWER 2128

616 E. WALTON AVENUE

DALTON, GA 30772-2128

CONTACT: MELANIE JOHNSON

PHONE: (800) 367 - 5504

EMAIL:A.JOHNSON@SHAWINC.COM

CONTACT: TODD HIELMAN

PHONE: (314)640 - 6521

EMAIL:TODD.HIELMAN@PATCRAFT.COM

ELEVATIONS

A204INTERIOR ELEVATIONS

A205INTERIOR ELEVATIONS

A206INTERIOR ELEVATIONS

A501DETAILS

A601DOOR SCHEDULE

A701WALL TYPES

03 Plumbing

P002PLUMBING GENERAL INFORMATION

P101SANITARY & VENT PIPING PLAN

P102PLUMBING DOMESTIC WATER FLOOR PLAN

P103DENTAL PIPING PLAN

P501PLUMBING DETAILS

P601PLUMBING SANITARY RISER DIAGRAM

P602PLUMBING DOMESTIC WATER RISER DIAGRAM

04 Mechanical

M001MECHANICAL GENERAL INFORMATION

M002MECHANICAL SCHEDULES

M101MECHANICAL FLOOR PLAN

M201MECHANICAL ROOF PLAN

M501MECHANICAL DETAILS

05 Electrical

E001ELECTRICAL SYMBOLS LEGEND AND GENERAL NOTES

E002ELECTRICAL SPECIFICATIONS

E003FLOOR PLAN POWER

E004FLOOR PLAN - LIGHTING

E005ELECTRICAL PANEL SCHEDULES AND RISER

E. TILE VENDOR:

ISC SURFACES 9245 DIELMAN INDUSTRIAL DRIVE ST. LOUIS, MO 63132 CONTACT: KEVIN PARDO PHONE: (636) 734 - 5080 EMAIL: kpardo@iscsurfaces.com

F. LIGHTING VENDOR:

CONTACT: MEGAN DONOGHUE PHONE: (860) 767 - 0110 x 232 EMAIL: mkd@sslighting.com

G. DENTAL EQUIPMENT:

PATTERSON DENTAL CONTACT: JOSEPH TECHAR PHONE: (651) 686 - 1600 EMAIL: joseph.techar@pattersondental.com

F. FIRE EXTINGUISHERS:

CONTACT: HD CONTACT SUPPLIES PHONE: (217) 540 - 5780 EMAIL: prosupplies@heartland.com

G. LOW VOLTAGE CABLING: HEARTLAND DENTAL CONTACT: JORDAN HULTS EMAIL: jhults@heartland.com

J. DIGITAL PANOREX AND X-RAY: CONTACT: ELIZSHA DARNELL PHONE: (217) 540 - 5658 EMAIL: edarnell@heartland.com

FINISH FLOOR LEGEND

1A3'-0"7'-0"SOLID C.W.WD21/A6012/A601STAIN-2

105 5A3'-0"7'-0"SOLID C.W.WD21/A6013/A601STAIN-6

107 1A3'-0"7'-0"SOLID C.W.WD21/A6012/A601STAIN-3

4A3'-0"7'-0"SOLID C.W.WD21/A6013/A601STAIN-3

4A2'-8"7'-0"SOLID C.W.WD21/A6012/A601STAIN-3

4A3'-0"7'-0"SOLID C.W.WD21/A6012/A601STAIN-3

4A2'-8"7'-0"SOLID C.W.WD21/A6012/A601STAIN-3

122 2A3'-0"7'-0"3/A6014/A601PAINT-5 123 1A3'-0"7'-0"SOLID C.W. HM1 1/A6012/A6013

1A3'-0"7'-0"SOLID C.W.WD21/A6012/A601STAIN-2

General Wall Type Notes:

5/8" GYPSUM BOARD

NOTE:

NOTE:

TO REMOTE SWITCH

ENTRY POINT FOR INTERCONNECTING CABLE WHEN REMOTELY MOUNTING OPERATOR CONTROL PANEL (SINGLE GANG BOX CAN BE USED) CABLE PROVIDED BY MANUFACTURER

4x4 POSTS (16" ON CENTER)

WALL MOUNTING PLATE PROVIDED BY MANUFACTURER

ENTRY POINT FOR INTERCONNECTING CABLE WHEN REMOTELY MOUNTING OPERATOR CONTROL PANEL (SINGLE GANG BOX CAN BE USED) CABLE PROVIDED BY MANUFACTURER

JUNCTION BOX POSITION FOR INTERCONNECTING CABLE WHEN REMOTELY MOUNTING OPERATOR CONTROL PANEL.

ELECTRICAL POWER ENTRY POINT

FLUSH MOUNTED SINGLE-GANG JUNCTION BOX

5/8" GYP. BOARD (BOTH SIDES) ATTACH DRYWALL TO ADDITIONAL FRAMING NOT 4X4 POSTS NOTE: X-RAY UNIT REQUIRES

COORDINATE WITH DENTAL

FOR SPANS LONGER THAN 9'-0" AND LESS THAN 12'-0", INSTALL 1/4" ALL THREAD ROD SUPPORTS AT THIRD SPAN LOCATION W/ 1" WASHER AND DOUBLE NUT. HANG FROM EXISTING JOISTS OR NEW UNISTRUT BETWEEN JOISTS (LOCATION OR CONFIGURATION VARIES). NO 2x6 COMPRESSION STUD REQUIRED.

5'-0" LONG 2x4 SECURELY FASTENED DIRECTLY TO STUDS WITH (8) #12 x 2 1/4" TEK SCREWS EACH END. MONITOR ARM MOUNTING PLATE. ANCHOR TO 2"x10" PER MANUFACTURERS RECOMMENDATIONS (6 FASTENERS MINIMUM).

VERTICAL EXTENSION OF MONITOR ARM

MONITOR ARM - SECTION

MONITOR ARM MOUNTING PLATE. ANCHOR TO 2"x10" PER MANUFACTURERS RECOMMENDATIONS (LOCATION VARIES).

FOR SPANS LONGER THAN 9'-0" AND LESS THAN 12'-0", INSTALL 1/4" ALL THREAD ROD SUPPORTS AT THIRD SPAN LOCATION W/ 1" WASHER AND DOUBLE NUT. HANG FROM EXISTING JOISTS OR NEW UNISTRUT BETWEEN JOISTS (LOCATION OR CONFIGURATION VARIES). NO 2x6 COMPRESSION STUD REQUIRED.

5'-0" LONG 2x4 SECURELY FASTENED DIRECTLY TO STUDS WITH (8) #12 x 2 1/4" TEK SCREWS EACH END

NOTE: 1. COORDINATE W/ EQUIPMENT MANUFACTURER REQUIREMENTS AND MEP DRAWINGS

FOR SPANS LESS THAN 9'-0", PROVIDE 2x6 COMPRESSION STUD. ANCHOR TO VERTICAL 2x8 w 1/4"x5" LAG SCREWS AT 12" O.C. PRE-DRILL HOLES PRIOR TO INSTALLATION.

2x4 (OFFSET FROM CENTER) VERTICAL SUPPORT AND 2x10 HORIZONTAL SPANNING WIDTH OF TREATMENT ROOM. FASTEN TOGETHER WITH 1/4"x5" LAG SCREWS AT 12" O.C. PRE-DRILL HOLES PRIOR TO INSTALLATION. TOP OF WALL BEYOND

SECURELY FASTEN BOTTOM 2x10 TO FIRE TREATED 2x4 WALL SUPPORT WITH (4) # 10x3" WOOD SCREWS AT EACH END.

FOR SPANS LESS THAN 9'-0", PROVIDE 2x6 COMPRESSION STUD. ANCHOR TO VERTICAL 2x8 W/ 1/4"x5" LAG SCREWS AT 12" O.C. PREDRILL HOLES PRIOR TO INSTALLATION.

2x4 (OFFSET FROM CENTER) VERTICAL SUPPORT AND 2x10 HORIZONTAL SPANNING WIDTH OF TREATMENT ROOM. FASTEN TOGETHER WITH 1/4"x5" LAG SCREWS AT 12" O.C. PRE-DRILL HOLES PRIOR TO INSTALLATION.