Skip to main content

Scare Tactics - Studio: Cultures, 2022

Page 1

SCARE TACTICS

Not c onst

ructe d yet

nB

e St Jubile

WHERE TREPIDATION MEETS SELF GROWTH...

Boun

dary

e

ary lin

Bound

line

At our facility, you will have the opportunity to safely experience what you otherwise may not, and reap the experiential rewards. Fear testing rooms of varying sizes are equipped with a range of devices to simulate tacticle and audio-sensory experience, in conjunction with virtual reality headsets to simulate the visual experience. This combination can appropriately the bodies natural response system, allowing the individual to become comfortable with repeated exposure.

The occupiers range between ages, education levels, backgrounds - the occupiers can be anyone who has a fear they want to overcome, stressful experiences they need to become comfortable in, or those who simply want to seek an adrenaline fueled thrill.

t

In high-stress work positions where the safety of an individual is at risk, such as in security, combat or emergency services, making considered decisions under stress is the difference between life and death. The simulation of real-life scenario’s as a training devicefor f uture agents will lead to better outcomes, as well as making the individual more comfortable in the workplace.

The users of this space can be split into two primary groups: employees and occupiers. The employee group contains a range of professionalss specialising in emotional and physical responses: scientists, researchers, engineers and mechanics. These employees are responsible for the users safety and wellbeing, and to ensure the effectiveness of the fear testing.

S Todd

80% of the participants involved in a near-death experience report a permanent improvement in their mood and emotions. This is believed to be the result of an increase in compassion and empathy for others. What if this effect could be simulated in a safe environment, socially engineering oneself to be a more caring individual.

on A

Secti

PROGRAM

Sectio

e rs ervic & visito s o t it aff ry/ex rk for st t n e side arpa Road ground c r unde

EMPLOYEES NEEDS

WANTS

SPACES

- FUNCTIONING FEAR ROOMS

- COMFORTABLE WORK

- RESEARCH LABORATORY

- RESEARCH FACILITIES

ENVIRONMENT

- OFFICE / COMPUTER SUITE

- EMPLOYEE PARKING

- WELL LIT RESEARCH SPACES

- STORAGE SPACE

- BATHROOM FACILITIES

- EMPLOYEE LUNCHROOM

t S t n ince

- BATHROOM FACILITIES

St V

OCCUPIERS NEEDS

WANTS

SPACES

- SIMULATIONS

- EFFECTIVE TREATMENT

- CONFINED TESTING ROOM

- VARIETY OF EXPERIENCES

- SELF REFLECTIVE SPACE

- SPACIOUS TESTING ROOM

- SAFETY

- CUSTOMER PARKING

- CAVERNOUS TESTING ROOM

- BATHROOM FACILITIES

- COMFORTABLE SPACES

- BATHROOM FACILITIES

SITE PLAN

1:500

STREET FRONT ELEVATION

1:200

BRIEF

CLIENT 1

CLIENT 2

POLICEMAN

LIBRARIAN

SAPOL Recruit undergoing mandatory training.

Managerial Librarian who suffers from social anxiety.

NAME: BEN THOMPSON AGE: 23 YEARS OLD OCCUPATION: POLICE RECRUIT WORKPLACE: PORT ADELAIDE POLICE STATION

NAME: MACIE WHITE AGE: 32 YEARS OLD OCCUPATION: MANAGERIAL LIBRARIAN WORKPLACE: ADELAIDE STATE LIBRARY

SITUATION

SITUATION

Aspiring SAPOL Cadet undergoing mandatory training.

Has been experiencing social phobia since a young age which has disadvantaged her adult life.

B

C

8400.00

Vehicular crash scene simulation, confrontational simulations, firearm course simulation.

Cafe ordering simulation (1-on-1) , navigating supermarket simulation, ordering at busy bar simulation.

F

G

8400.00

8400.00

6650.00

6650.00

8400.00

8400.00

F

6650.00

6650.00

H

I

6650.00

UP

G

H

I

J

8400.00

8400.00

6650.00

6350.00

J

6350.00

LIFT

2

LIFT

3 1

LIFT

8400.00

AA

8400.00

8400.00

6125.00

2

REQUIRES

E

66025.00

2

REQUIRES

8400.00

E

D

6000.00

A

DESIRED OUTCOME

Repeated exposure may provide improved results.

D

1

8400.00

Failure to display the necessary skills throughout the course will result in the indivual repeating.

8400.00

6125.00

Suffered a traumatic incident in her private life, which has burdened her life with crippling social phobia.

Wishes to simulate common social interactions in both 1-on-1 and group settings to improve her ability to function and 1 well-being.

C

66025.00

37500.00

To undergo routine fire-arm training, de-escalation training and various field training exercises.

B

BB

AA

DESIRED OUTCOME

A

6000.00

Has never been in a high-pressure situation, where his decisions are to be of precision and dire importance.

BB

UP

LIFT

2

3

LIFT

4

3

4

LIFT

UP

1

8400.00

8400.00

37500.00

LIFT LIFT

4 3

5 6300.00

4 8400.00

UP

6

6300.00

5

6

N 1 2

-

ATRIUM ELEVATOR WAITING SPACE

3 4

-

PATHWAY TO/FROM LARGE FEAR ROOM LARGE FEAR ROOM

GROUND FLOOR PLAN STREET ENTRY

1:200

N

ATRIUM RECEPTION DESK

+33000.00 EXISTING LEVEL 9

+29600.00 EXISTING LEVEL 8

+25900.00 EXISTING FFL 7

+22200.00 EXISTING FFL 6

GROUND FLOOR ELEVATOR LOBBY

+18500.00 EXISTING FFL 5

LARGE TESTING ROOM STAIRCASE

+14800.00 EXISTING FFL 4

A

+11100.00 EXISTING FFL 3

+7400.00 EXISTING FFL 2

FFL +3700.0mm EXISTING FFL 1

FFL 0.00mm GROUND LEVEL

FIFTH LEVEL OFFICE VIEW

ROOFTOP SEATING SPACE

SECTION B

1:100

Arch7032 Studio Cultures Matthew Nayda A1706845


DESIGNPROCESS B

C

D

E

F

G

H

C

A F

A

H

B I D

E

G

I

STRUCTURAL COLUMNS

PRIMARY STRUCTURE

Structural steel columns will vertically transfer loads to the ground level. These vertical structural members will also allow for the secondary structural system to be fixed to the structural system.

The primary structure consists of a steel column, beam and slab construction. Structural steel allows for large spans to be gapped and tall heights to be reached.

FLOORPLATES & FABRIC

STRUCTURE, FABRIC & FLOORPLATES

The structural floorplates will be of reinforced concrete construction. These floorplates will be nestled into the built fabric, and will be at the same finished floor levels as the M+H building for ease of construction.

The second-order structure is a steel space frame, consisting of a triangulated frame to brace Glass Reinforced Concrete (GRC) panels to form the building facade. Within the existing M+H building, this framing can be easily constructed to form the building interior. For the external facade, the secondary structure will be attached to the primary structure (to engineers specifications) to transfer loads to the ground.

REAR ELEVATION

1. 500m site visit map depicting community mural locations found on journey

2. Photographed murals visited whilst on site

3. Layered and combined with varying opacities

5. Open collage in Illustrator, high-fidelity image trace to extract curves

6. Import curves into Rhino, red squares indicate my future iterations

7. Isolate small area within curve mass and extract

8. Arrange these curves into x, y and z planes with the help of Bounding Box

9. Project the intersections of selected curves into 3-dimensions with Crv2View

10. Extract points (vertices) of these curves with ExtractPt

11. Create a 3-dimensional mesh from these points with MeshFromPoints

12. Reduce + Simplify mesh, top view, iterations.

13. Iterations were assessed for best spatial qualities

14. Chosen iteration was then connected with M+H Building in various ways

15. Iterations were assessed again for best spatial qualities

16. Best iteration was then developed + reduced into its final form based on the idenitified locations + views as shown below.

Atrium

1:200

On-arrival Waiting space

Final fear room + Exit

BB

BB

A A

Exit pathway leading to atrium

4. Reduced to black and white to expose contrast

B

C

D

E

F

G

H

I

B

C

D

E

F

G

H

J 53025.00

66025.00

BB 8400.00

6125.00

8400.00

8400.00

6650.00

6650.00

8400.00

8400.00

6650.00

F

G

H

I

A

J 10

8400.00

6650.00

LIFT

G

6650.00

H

I

8400.00

8400.00

2

LIFT

8400.00

1

37500.00

3

6350.00

LIFT LIFT

8400.00

LIFT UP

LIFT

2

LIFT

1

LIFT

6650.00

14

15

16

13 4 3

5 4

6300.00

5

8400.00

UP

LIFT

4

8400.00

UP

4

9

7

6650.00

6650.00

12

3

8

J

LIFT

8400.00

LIFT

AA

8400.00

37500.00

3

6 UP

8400.00

11

2

UP

UP

8400.00

UP

8400.00

1

LIFT

LIFT

4

8400.00

6125.00

6350.00

8400.00

AA

UP

LIFT

E

D

8400.00

8400.00

3

LIFT

F

6650.00

66025.00

AA

6650.00

6000.00

6650.00

8400.00

8400.00

C

2

5

LIFT

B

66025.00 8400.00

6000.00

E

D

8400.00

C

31200.00

6000.00

B

8400.00

8400.00

1

2

5.00

8400.00

6350.00

1

A

8400.00

6125.00

BB

6

6300.00

5

6

5 6 7

-

FEMALE OCCUPIER BATHROOM FACILITIES MEDIUM SIZED FEAR ROOMS SMALL FEAR ROOM

8 9 10

THIRD FLOOR PLAN

-

MALE OCCUPIER BATHROOM FACILITIES OCCUPIER PATHWAY TO LARGE FEAR ROOM CLIMBING STAIRWAY TO LARGE FEAR ROOM

1:200

N

11 12 13

-

FEMALE STAFF BATHROOM FACILITIES STORAGE SPACE OFFICE SPACE (EQUIPPED WITH COMPUTER LAB)

FIFTH FLOOR PLAN

14 15 16

-

RESEARCH LABORATORY SPACE STAFF BREAK ROOM MALE STAFF BATHROOM FACILITIES

1:200

N

+33000.00 EXISTING LEVEL 9

+29600.00 EXISTING LEVEL 8

+25900.00 EXISTING FFL 7

+22200.00 EXISTING FFL 6

+18500.00 EXISTING FFL 5

+14800.00 EXISTING FFL 4

+11100.00 EXISTING FFL 3

+7400.00 EXISTING FFL 2

FFL +3700.0mm EXISTING FFL 1

FFL 0.00mm GROUND LEVEL