EMR GLOBAL · TRANSFORMER COMPONENTS NICHE

TECH BRIEF — POWER-TRANSFORMER OLTC + AIGCS

POWER-TRANSFORMER OLTC & NITROGEN CONSERVATION TYPE V · TYPE M · TYPE D · DETC + Automated Inert Gas Conservation System (AIGCS) A focused brief for transmission-class substations (40 kV – 765 kV)

Verified data from emr.global product pages · Reinhausen technology stack under EMR manufacturing (100% subsidiary since Feb 2024)

EMR Global — verified emr.global product pages · Sep 2026

Page 1


EMR GLOBAL · TRANSFORMER COMPONENTS NICHE

TECH BRIEF — POWER-TRANSFORMER OLTC + AIGCS

1 · Why pair a heavy-duty OLTC with nitrogen blanketing? A power transformer in the 40 kV – 765 kV class carries three age-acceleration vectors that a specifier should attack in parallel: (a) voltage drift on the bus without on-load correction, (b) oxygen-driven insulation-oil oxidation inside the main tank, and (c) moisture ingress through the conservator breathing cycle. A heavy-duty OLTC (TYPE V/M/D/DETC) addresses (a) by holding the transmission bus inside the grid-code band continuously under load. AIGCS addresses (b) and (c) by holding a 3 – 7 PSI nitrogen blanket over the oil in the main tank — eliminating the air contact that drives oxidation and the breathing that brings moisture in. Together they raise both the availability and the dielectric-life of the same transformer. What this brief is: a spec-ready summary of the TYPE V / M / D / DETC OLTC family and the AIGCS envelope, with the figures that buyers need for tender specs. What it isn't: a marketing pamphlet or a stock-price readout — EMR Global is unlisted. Source: emr.global (TYPE V / TYPE M / TYPE D / DETC page, AIGCS page) — verified Sep 2026.

EMR Global — verified emr.global product pages · Sep 2026

Page 2


EMR GLOBAL · TRANSFORMER COMPONENTS NICHE

TECH BRIEF — POWER-TRANSFORMER OLTC + AIGCS

2 · OLTC Family — TYPE V / TYPE M / TYPE D / DETC (verbatim, Sep 2026) All figures from the EMR Global product page for on-load and de-energised tap-changers for power transformers. Family

Current Rating

Voltage Class

Vector

BIL (kV/kVp)

Step Voltage

Max Positions

TYPE V (compact) 200 / 350 / 500 A 3-pole: 200/350/500 A · 1-pole: 350/700 A

40 / 76 / 123 kV

Y, D

70/200 → 230/550

1500 V

14 linear → 27 with pre-selector

TYPE M (765 kV class) 3-pole 350–700 A · 1-poleUp 350–2400 to 765 kV A 3-pole: 350/500/600/700 A · 1-pole: 350–1800 A

Y, D

High impulse per design

Up to 3300 V

Up to 35 (with pre-selector)

TYPE D (legacy, 1975+) Proven on heavy furnace duty

Up to 220 kV

Y, D

Per IEC 60214

Up to 2500 V

Up to 35 with pre-selector

11 – 300 kV

Y, D

Per IEC 60214

Per tap

Per design (off-load switching)

Up to 1500 A (1-pole)

DETC (de-energised) Per design OC-R rotary 11–145 kV · OC-P belt-pad up to 300 kV

Engineering read. TYPE V is the compact-economical choice up to 132 kV with selectable bi-directional power flow and 14–27 positions. TYPE M is the modern, superior family for 765 kV with high-speed resistor transition + first-current-zero arc extinction at the diverter. TYPE D is the >1975 time-tested platform on >1500 in-tank references including heavy furnace duty at 500 ops/day. DETC covers off-load switching on smaller distribution and pad-mount banks. All four are mounted to IEC 60214. Vacuum switching available. Source: emr.global/oltc-detc-for-power-transformers/ — product spec table on that page.

EMR Global — verified emr.global product pages · Sep 2026

Page 3


EMR GLOBAL · TRANSFORMER COMPONENTS NICHE

TECH BRIEF — POWER-TRANSFORMER OLTC + AIGCS

3 · AIGCS — Automated Inert Gas Conservation System Purpose: maintain a nitrogen blanket at 3 – 7 PSI inside the power-transformer main tank. Architecture: • Control. PLC + HMI for real-time operation and event logging; password-protected setpoints on the HMI. • Valves. Dual solenoid valves — SV1 (inlet) and SV2 (exhaust) — sequenced by the PLC. • Sensing. Electronic pressure transmitters on the tank and on the nitrogen cylinder, plus dual-stage pressure regulator. • Communications. RS-485 SCADA for remote monitoring and event/alarm forwarding. • Enclosure. Compact skid-mounted design; IP55 stainless-steel enclosure option for outdoor / corrosive environments. What it kicks out of the failure-mode budget. First, oxygen-driven oil oxidation — the dominant ageing vector in an open-breathing conservator system. Second, atmospheric moisture ingress on every thermal breathing cycle — the second most damaging vector, and the one that drives dissolved-gas-analysis alarms and the online moisture-in-oil reading. With both blocked, the transformer's insulation life extends measurably, and the gas-side operating envelope becomes essentially maintenance-free between scheduled overhauls. Source: emr.global/aigcs/ — verified Sep 2026.

EMR Global — verified emr.global product pages · Sep 2026

Page 4


EMR GLOBAL · TRANSFORMER COMPONENTS NICHE

TECH BRIEF — POWER-TRANSFORMER OLTC + AIGCS

4 · Where to Spec & Contact Spec the heavy-duty OLTC from the relevant product page: Power-Transformer OLTC & DETC — https://emr.global/oltc-detc-for-power-transformers/

Pair it with the nitrogen blanketing system: AIGCS — Automated Inert Gas Conservation System — https://emr.global/aigcs/

Request a tailored quote / site assessment: Contact EMR Global — https://emr.global/contact-us/ EMR Global is the unlisted Indian manufacturing arm of EMR Tap Changers Pvt. Ltd. (formerly Easun-MR Tap Changers); 100% subsidiary of Maschinenfabrik Reinhausen GmbH since 1 Feb 2024. Manufacturing: Chennai & Puducherry, India. All product specs above were verified against the named emr.global pages this turn.