Skip to main content

Midline Design Guidelines

Page 1

September 2026

The Midline INDUSTRIAL USE DESIGN GUIDELINES Cleveland, Ohio PR E PA R E D F OR

P R EPAR E D BY

Site Readiness Fund for Good Jobs LAND studio

Utile Merritt Chase


LEGEND Midline Boundary Industrial Use Active Use (Lobby, Commercial, etc.) Mixed-Use / Residential Infill Open Space Midline Greenway

2

THE MIDLINE | Industrial Use Design Guidelines


TH E M I D LI N E • I N DU STRIA L U S E DESIGN GUIDELINES

Contents 01

Introduction

02

Site Layout

03

Landscape Design

04

Building Design

05

Additional Guidelines

04

Purpose, Principles, Key Terms, Street Activation Hierarchy

10

Site Placement Overview, Integrating the Greenway

16

Frontage Zone, Stormwater Management, Planting Buffer

20

Facade Articulation, Building Signage

30

Front and back cover photos by Patrick Fenner. All other photo credits can be found on pages 32-33.

Contents

3


SEC TI O N 0 1 • I NTRO D UCTI O N

Purpose These Guidelines complement the Midline Master Plan and serve three main purposes: 1. Guide building and site design Establish clear expectations for site planning and design quality to guide SRF’s conversations with companies and developers. 2. Design the District as one place Promote a visually appealing and coherent 21st century business district across industrial buildings, associated open space, the Midline Greenway, and the broader public realm. 3. Inform new zoning Establish draft dimensional standards that can inform a new zoning overlay or a version of the Cleveland Neighborhood FormBased Code specific to the Midline Business District. The Guidelines establish design principles that apply across the District, but each Development Zone’s unique size, shape, and adjacencies will impact how the principles are applied. For examples of how these principles play out on individual sites, please refer to the Midline Test-fit Cutsheets document.

4

THE MIDLINE | Industrial Use Design Guidelines


MASTER PLAN FRAMEWORK The Framework transforms 350+ acres of underutilized land into a connected business district and greenway.

Introduction

5


SEC TI O N 0 1 • I NTRO D UCTI O N

Governing Principles The Design Guidelines are built on these underlying design principles: 1. Create a consistent street wall and streetscape across the district (as opposed to parcel-by-parcel customization).

6

2. Integrate the Midline Greenway, where applicable, with added setbacks, enhanced landscapes, and building articulation. 3. Prioritize active human-centered uses close to and facing public streets (such as lobbies, offices, and accessory retail).

4. Balance pedestrian and bicycle accommodations with truck access. 5. Leverage stormwater management as visual amenity. 6. Buffer industrial uses from existing residential fabric.

THE MIDLINE | Industrial Use Design Guidelines


Applicability & Key Terms Applicability

Key Terms

The Cleveland Midline Industrial Use Design Guidelines apply to the following industrial uses and their accessory uses. These use categories align with those in the Neighborhood Form-Based Code.

The terms below are common to most Form-Based Codes; those highlighted in orange have been tailored to industrial uses in the Midline Business District.

• Light Industrial • Makerspace • Research & Development • Warehouse & Distribution • Accessory Uses (such as office and retail)

ACTIVE USE Human-centered use, such as lobby, office, commercial, retail, employee common areas, makerspace, etc. FACADE The exterior wall of a building oriented in whole or in part toward a front lot line or the Midline Greenway. FACADE BUILD OUT The ratio of the facade width to the lot width, calculated by dividing the cumulative facade width by the lot width. FENESTRATION The openings in the facade of a building, including windows and doors. FRONTAGE ZONE The area of a lot between the building facade(s) and the Active-Street front lot line(s), extending fully to each side lot line(s), or the area between a building and the Midline Greenway where the two are located within 30 ft of each other.

Introduction

FRONTAGE ZONE TYPE A distinct combination of open space and landscape design features located in the Frontage Zone. LOT LINE The boundary that legally and geometrically demarcates a lot. LOT LINE, FRONT Any lot line abutting a thoroughfare, excluding an alley. LOT LINE, SIDE Any lot line other than a front or rear lot line. LOT LINE, REAR Any lot line which is parallel to or within forty-five (45) degrees of being parallel to a front lot line, unless that lot line is a side lot line of an abutting lot. LOT WIDTH The length of the front lot line of a lot. PRINCIPAL ENTRANCE The addressed entrance to a building or commercial space.

7


SEC TI O N 0 1 • I NTRO D UCTI O N

Street Activation Hierarchy Prioritize Active Streets and the Midline Greenway The Guidelines establish a Street Hierarchy in the District to guide how sites should respond to different public streets, placing the highest design expectations on Active Streets and the Midline Greenway. All highlighted streets in orange (on the map at right) are designated as Active Streets, intended to

be the most activated, walkable/ bikeable, and visually appealing. All other public streets are considered Secondary Streets, intended for general circulation and servicing access. For the purposes of this document, the Midline Greenway is conceived of as a public street and is situated between Active Streets and Secondary Streets in this hierarchy.

Greenway are the most visible and important in terms of the district’s urban design goals and are therefore subject to more design guidelines. Where a lot fronts on multiple Active Streets, the project proponent may choose only one (or more) as the designated Active Street(s) for the purposes of following the design guidelines in this document.

Buildings and open spaces along Active Streets and the Midline

Applicable Design Guidelines Maximum Front Setback

Active Street Midline Greenway Secondary Street

•

Minimum Facade Buildout

Curb Cut Limitation

Active Use Placement

Principal Entrance Placement

Frontage Zone Type Requirement

Building Facade Articulation

Minimum Parking Setback

Street Buffer Requirement

• • • • • • • • • • • • • • • • • •

= Where a design guideline applies wholly or conditionally

= Where a design guideline does not apply or is not applicable

ACTIVATION HIERARCHY The more activation a street is intended to support, the more design guidelines apply along it.

8

THE MIDLINE | Industrial Use Design Guidelines


Active Street Midline Greenway Secondary Street

Street Hierarchy

Introduction

9


SEC TI O N 0 2 • S ITE L AYO U T

Site Placement Overview Engage the street, hide the parking/loading apron, and buffer the edges To promote a consistent street wall and an enhanced public realm, particularly along designated Active Streets, industrial buildings should be placed close to the street, built out to

Plan View

a minimum percent of the lot width, and programmed with ground floor active uses facing that street. Parking and loading aprons should be placed to the side or rear of the building, with curb cuts located only on Secondary Street(s), where possible. Stormwater management areas can be placed anywhere on site, but should be designed as a visual amenity where

Place parking, loading, and service areas to the side and rear

Buffer parking, loading, and service areas from streets and neighbors

Design stormwater detention as visual amenity

Place industrial buildings within 10 to 20 feet of the street

10

visible from the public realm. Lastly, the site should provide a planting buffer between parking/loading aprons and public streets, and along side and rear lot lines.

Place Active Uses on Active Streets

THE MIDLINE | Industrial Use Design Guidelines


Building Placement A Front Setback Active Street (min/max) Secondary Street (min) B Side Setback (min) Abutting a non-R Dist.

Parking/Loading Placement 10 ft / 20 ft 10 ft 25 ft

Abutting an R District C Rear Setback (min) Abutting a non-R Dist.

40 ft

Abutting an R District

40 ft

15 ft

Active Street

60%

Secondary Street

None

Building Massing

Side or Rear Only

D Front Setback (min) Active Street Secondary Street E Side Setback (min) F Rear Setback (min)

Facade Line 10 ft 8 ft 8 ft

Curb Cut Placement Location

Facade Build Out (min)

Height in Stories (max) Height in Feet (max)

Location

Side or Rear Only

Distance Between 200 ft Curb Cuts (min) G Curb Cut Width (max) If serving trucks 28 ft If not serving trucks 24 ft

4 Stories 85 ft

Aerial View Place parking, loading, and service areas to the side and rear

Site Features Placement Stormwater Front, Side, Detention Area or Rear Location Perimeter Planting Buffer (min) N/A: See From Active-Street A Frontage Front Lot Line Zone Types From Secondary10 ft Street Front Lot Line E, From Side/Rear Lot 8 ft F Line

Building Features Placement Active Use Location Principal Entrance Location

Only on Active Street or within 30 ft of Greenway 20 ft

Active Use Depth (min) Active Use 60% Fenestration (min)

Buffer parking, loading, and service areas from streets and neighbors

Design stormwater detention as visual amenity

Place Active Uses on Active Streets Place industrial buildings within 10 to 20 feet of the street

Site Layout

11


SEC TI O N 0 2 • S ITE L AYO U T

Site Placement — other Lot Types Interior Lot Alternate Layout (Rotated 90°)

Place Active Uses on the Active Street

Building, Active Use, and the Frontage Zone should front on the Active Street. Parking, loading, and curb cut access should be located to the side.

Place the curb cut to the side

Through Lot

Place the curb cut on the Secondary Street

Building, Active Use, and Frontage Zone should front on the Active Street. Parking and loading should be located at the rear; and curb cut access should only be located at the Secondary Street.

Place Active Uses on the Active Street

Frontage Zone Truck Access 12

THE MIDLINE | Industrial Use Design Guidelines


Corner Lot Building should be built to the street corner, with the Active Use and Frontage Zone fronting on the Active Street. Parking and loading should be located at the rear; and curb cut access should only be located at the Secondary Street.

Place the curb cut on the Secondary Street

Place Active Uses on the Active Street

3-Frontage Lot

Place the curb cut on one of the Secondary Streets

Building should be built to either street corner, with the Active Use and Frontage Zone fronting on the Active Street. Parking and loading should be located at the side/rear; and curb cut access should be located at either Secondary Street.

Place Active Uses on the Active Street

Site Layout

13


SEC TI O N 0 2 • S ITE L AYO U T

Integrating the Greenway Accommodate and activate the Midline Greenway A critical part of the public realm, the Midline Greenway weaves through the District and may run along the front, side, or rear of lots. Its integration into new development should follow these design guidelines: 1. Where the Greenway is located along a specific setback (i.e., front, side, or rear), that setback is increased by the width of the Greenway (min and, where applicable, max). 2. Where the Greenway and a building are located within 30 ft of each other, the area in between is also a Frontage Zone. Where this distance is greater than 30 ft, there should be a minimum 10 ft planting buffer from the edge of the Greenway. 3. Where a building facade is within 200 ft of the Greenway and is oriented toward it, this facade should be articulated using one or a combination of the strategies in Section 04: Facade Articulation Guidelines.

14

Midline Greenway SRF Parcels

THE MIDLINE | Industrial Use Design Guidelines


Example Lot WITHOUT the Midline Greenway

Front Setbacks (min & max)

Side/Rear Setback (min)

Example Lot WITH the Midline Greenway

Where a building facade is within 200 ft of the Greenway, this facade should be articulated

Where a building is within 30 ft of the Greenway, the area in between is also a Frontage Zone Total Front Setbacks (min & max) = Front Setbacks (min & max) + Width of Midline Greenway

Site Layout

Total Side/Rear Setback (min) = Side/Rear Setback (min) + Width of Midline Greenway

15


SEC TI O N 0 3 • L A N D SC A PE DES I GN

Frontage Zone Guidelines Activate the sidewalk and the Midline Greenway with Frontage Zone Types The Frontage Zone is defined as the area between the building facade line and the Active-Street front lot line (for the full width of the lot) or the area between a building and the Midline Greenway where the two are located within 30 feet of each other.

As the interface between the building and the public realm, the Frontage Zone should activate the sidewalk/ Midline Greenway and provide visual amenities. The open space and landscape design should be enhanced by following one (or a combination) of these Frontage Zone Types:

No driveway, except for access, should be located in the frontage zone. Mechanical equipment (e.g., transformers) should not be placed in the frontage zone unless screened by a fence and/or plantings.

• Stormwater Feature • Plaza and Public Amenities • Native Planting Buffer

Frontage Zone Types

Use Frontage Zone Types to activate and enhance the streetscape; select only from the three types shown here 16

THE MIDLINE | Industrial Use Design Guidelines


Stormwater Feature An intentionally-designed stormwater management area (e.g., rain garden, bioswale) that also serves as a visual amenity for the public realm.

Plaza and Public Amenities A highly paved area at least 30 feet wide (measured along the building facade) providing a widened sidewalk and building access, with added public amenities, such as seating, bicycle parking, and shade trees.

Native Planting Buffer An area planted with perennials and native species that increases pervious area and also serves as a visual amenity for the public realm.

Avoid Lawn, Asphalt, Fencing, and Mechanical Equipment Open spaces that appear as “leftover”, fenced off, or utility areas are unapproachable and detract from a vibrant pedestrian experience.

Image: Google Street View, captured Jul 2019

Landscape Design

Image: Google Street View, captured Jun 2026

17


SEC TI O N 0 3 • L A N D SC A PE DES I GN

Stormwater Management Maximize green stormwater infrastructure and leverage it as visual amenity All pervious open spaces on a lot should be used to maximize green stormwater infrastructure, including rain gardens, bioswales, infiltration beds, and planted detention areas. These features should follow LowImpact Development (LID) best practices to slow, capture, filter, infiltrate, and reuse stormwater as close to its source as possible. Stormwater management should contribute to the district identity by making water visible, legible, and attractive. Stormwater areas should be integrated into the overall site design rather than treated as leftover utility zones. These landscapes should demonstrate that industrial sites can be functional, resilient, and publicly engaging. Stormwater management should be located along parking lot edges, building frontages, service drives, trail connections, and open space areas.

Linear Stormwater Management

Stormwater Management and Circulation

Seasonal Interest

Seasonal Interest

Drought Tolerant Species

Planting should emphasize droughttolerant, salt-tolerant, and pollutiontolerant species appropriate for industrial conditions. Designs should account for long-term maintenance, sediment removal, safe access, and seasonal appearance. Where required, fencing should be minimal and visually coordinated with the site. 18

THE MIDLINE | Industrial Use Design Guidelines


SEC TI O N 0 3 • L A N DSC A PE DES I GN

Planting Buffer Guidelines Buffer industrial uses from public streets and along side/ rear lot lines To buffer industrial uses, all lots should provide a minimum planting buffer: 8 feet from side/rear lot lines, and 10 feet from front lot lines along Secondary Streets and the Midline Greenway where the latter is more than 30 feet from a building.

Sidewalk Planting Buffer

Trail Planting Buffer

Trees should be planted at an average 30 feet on center, with a minimum 2-inch caliper at planting. Spacing may vary due to site constraints, maintaining a continuous buffer. Where space permits, buffers should use multiple rows for a fuller screen. Buffers should prioritize hardy, low-maintenance species suited to industrial conditions (e.g., road salt, compacted soils, heat, drought, inundation). Designs should maximize native and climate-adapted species and minimize turf grass except where necessary for access or maintenance. Buffers should form a dense screen year round.

Trail Planting Buffer

Where outdoor service areas (e.g., loading aprons, trash areas) are visible from an abutting residential district, the planting buffer should include an opaque wall/fence 6-8 feet tall placed adjacent to the lot line. Parking Planting Buffer

Landscape Design

Sidewalk Planting Buffer

19


SEC TI O N 0 4 • B UI L D I NG DES I G N

Facade Articulation Guidelines Break down the scale of industrial buildings

Greenway should be articulated using one or a combination of these strategies:

To break down the scale of large, long industrial buildings and promote a more visually appealing public realm, building facades oriented toward an Active Street or within 200 feet of a Secondary Street or the Midline

• Windows/Fenestration • Varied Roof Form • Horizontal Layering • Vertical Planes • Massing Shifts • Textured Surfaces

Facade articulation strategies should not be added on as an afterthought but should be integrated with the holistic design of the building, such as in terms of structure, interior program, circulation, and in relationship to the context.

A Relevant Example from the District 7000 Central, a historic industrial building near the center of the District, articulates its facades as horizontal layers of varied material and fenestration, breaking down the scale of its long walls and providing a human-scale rhythm to the street. Image: Google Street View, captured Aug 2014

Avoid Blank Walls Industrial buildings with expansive and unarticulated facades are imposing in scale, lack visual interest, and do not contribute to the public realm.

Image: Google Street View, captured Jan 2025

20

THE MIDLINE | Industrial Use Design Guidelines


Windows/ Fenestration

Varied Roof Form

Horizontal Layering

Vertical Planes

Massing Shifts

Textured Surfaces

Building Design

21


Facade Articulation: Windows/Fenestration Fenestration should be at least 60% at any ground floor active use frontage (e.g., lobbies, accessory retail, office, etc.) and 20% at all other uses. Blank walls between windows should be no more than 25 feet wide.

Storefront System Photo: XX

Full-Height Vertical Windows

22

Punched Windows

Ribbon Window

THE MIDLINE | Industrial Use Design Guidelines


Facade Articulation: Varied Roof Form Varied roof forms should be pitched (e.g., gabled, sawtooth, etc.) vertical extrusions of at least 8 feet from the adjacent roof elevation, or some combination thereof. The minimum slope for a pitched roof should be 15 degrees.

Sawtooth Roof with Skylights

Gabled Roof Line

Building Design

Asymmetrical Roof Line

Crenelated Roof Line

23


Facade Articulation: Horizontal Layering Horizontal layering should consist of 3 to 5 “layers” whose differences are conveyed by a clear change in materials, textures, patterns, fenestration, colors, and/or murals. Each layer should span the full facade in width and at least 3 feet in height.

Textured Surface above a Stone Base

Corrugated Metal, Ribbon Window, and Brick Base

Panelized Metal above a Hollow Concrete Block base

24

Corrugated Metal above a Brick Base

THE MIDLINE | Industrial Use Design Guidelines


Facade Articulation: Vertical Planes Vertical planes should consist of multiple planes whose differences are conveyed by a clear change in materials, textures, patterns, fenestration, colors, and/or murals. Each plane should span the full height and be at least 15 feet in width.

Alternating Materials and Colors

Framed Mural at 4600 Euclid Ave (Cleveland Walls!)

Full-Wall Mural at 6917 Carnegie Ave (Cleveland Walls!)

Alternating Cladding and Windows

Building Design

25


Facade Articulation: Massing Shifts Massing shifts should consist of a clear change in facade plane and material by at least 4 feet in depth and 20 feet in width. The massing shifts can extend outwards or recess inwards relative to adjacent massings.

Angled Facade

Recessed Loading Bays

Indented Entryway

Shifting Building Massing

26

THE MIDLINE | Industrial Use Design Guidelines


Facade Articulation: Textured Surfaces Textured surfaces should be made of a consistent material and orientation, and the pattern should be at least 4 inches in total depth.

Precast Concrete Cladding

Overlapping Metal Louvers

Zigzag Metal Paneling

Perforated Corrugated Metal

Building Design

27


SEC TI O N 0 4 • B UI L D I NG DES I G N

Signage Design Guidelines Use building signage to announce the business and add character to the District Building signage should advertise the industrial use, accentuate the architecture, and add visual interest to the public realm. Signs should be one of the types illustrated in the diagram below:

• Large-Scale Individual Letters (mounted on the roof/facade) • Flat Signs • Vertical Blade Signs • Hand-Painted Mural Signs (i.e., no billboards) • 3D Logo Signs

such as displaying hand-painted mural signs as vertical planes or integrating flat signs into a textured-surface facade.

Signage may also be integrated into the facade articulation strategy,

Encouraged Signage Types

Large-Scale Individual Letters Blade Sign

Hand-Painted Mural Sign 3D Logo Sign Flat Sign

28

THE MIDLINE | Industrial Use Design Guidelines


3D Logo Sign

Mural Sign integrated with a Textured-Surface Facade

Large-Scale Individual Letters and Flat Sign

Blade Sign

Hand-Painted Mural Sign

Large-Scale Individual Letters (Roof-Mounted)

Building Design

Hand-Painted Mural Sign

29


SEC TI O N 0 5 • A D DITI O NA L G UI DELINES

Additional Design Guidelines Future-proof roofs for PV solar systems Building roofs should be designed to be PV-ready, in terms of structural capacity, area reservation, orientation, pitch, drainage, and durability.

Provide landscape strips and tree pits in parking lots For parking lots visible from a public street or the Midline Greenway, a landscaped island with a planted tree should be placed every 10 parking spaces.

Screen mechanical equipment, trash, and utilities Where visible from a public street or the Midline Greenway, mechanical equipment, trash, and utilities (e.g., transformers, etc.) should be fully screened from view with planting and/ or fencing.

30

THE MIDLINE | Industrial Use Design Guidelines


Maintain minimum sidewalk widths When development occurs on any lot abutting a sidewalk that is less than ten (10) feet in total width, inclusive of the furnishing zone, buildings should be set back an additional distance such that a sidewalk of at least ten (10) feet in width is provided, inclusive of the furnishing zone. The minimum and maximum front setbacks are increased accordingly.

Image: Google Street View, captured May 2023

Image: Google Street View, captured Jun 2026

Provide continuous sidewalks at curb cuts The grade, cross slope, and clear width of the walkway of a sidewalk should be maintained between the driveway apron and the abutting driveway. The appearance of the walkway (i.e., scoring pattern or paving material) should indicate that, although a vehicle may cross, the area traversed by a vehicle remains part of the pedestrian sidewalk.

Additional Guidelines

31


Photo Credits All drawings, diagrams, and renderings are by Utile. Page 1 (front cover):

• Photo: Patrick Fenner Page 17 (clockwise from top left):

•

• • • • • •

Page 18 (clockwise from top):

• • •

•

• •

•

•

32

Landscape Architect: STIMSON Studio. Photo: Charles Mayer Photography Pulaski Park, Northampton, Massachusetts. Landscape Architect: STIMSON Studio. Photo: Charles Mayer Photography Town Branch Commons Greenway, Lexington, Kentucky. Landscape Architect: SCAPE. Photo: SCAPE and Ty Cole Girondins Development Area Streetscape, Lyon, France. Landscape Architect: BASE Landscape Architecture. Photo: Thierry Demko Buffalo Niagara Medical Campus Streetscape, Buffalo, New York. Landscape Architect: SCAPE. Photo: nARCHITECTS

Page 24 (clockwise from top left):

• Aragon Grup Headquarters, Romania. • • •

Architect: Ene+Ene Arhitectura. Photo: Iulius Cristea Royal Tichelaar Factory, Netherlands. Architect: MONADNOCK. Photo: Stijn Bollaert HeyTown Art Center, Beijing, China. Architect: META-Project. Photo: Haiting Sun ForD Warehouse, Hangzhou, China. Architect: SAY Architects. Photo: RAWVISION studio

Page 25 (clockwise from top left):

Page 20 (from top):

• Cargocenter Frankfurt. Architect: Kölling

• Image: Google Street View, captured Aug

• Mural at 4600 Euclid Avenue, Cleveland

2014

Architekten. Photo: Christoph Kraneburg

• Image: Google Street View, captured Jan 2025

•

Page 22 (clockwise from top left):

•

• Aragon Grup Headquarters, Romania. • •

• The Atlanta BeltLine, Atlanta Georgia. Photo: Jamestown Wisconsin Native Plant Garden, UW– Madison Arboretum, Madison, Wisconsin. Photo: UW–Madison Arboretum Atlanta BeltLine Historic Fourth Ward Park / Eastside Trail Gateway, Atlanta, Georgia. Landscape Architect: TSW Design. Photo: TSW Design Ferrous Foundry Park, Lawrence, Massachusetts. Landscape Architect: STIMSON Studio. Photo: STIMSON Studio, Ngoc Doan Ferrous Foundry Park, Lawrence, Massachusetts. Landscape Architect: STIMSON Studio. Photo: STIMSON Studio, Ngoc Doan

Soppelsa Architekten. Photo: Beat Bühler

• Pulaski Park, Northampton, Massachusetts.

• Mill 19, Pittsburgh, PA. Landscape Architects: TEN x TEN, D.I.R.T. Studio. Photo: Gaffer Photography DuPont Peters Cartridge Factory Phytoremediation, Mason, Ohio. Photo: Williams Creek Management Corporation Core City Park, Detroit, Michigan. Landscape Architect: D.I.R.T. Studio. Photo: Prince Concepts Buffalo Niagara Medical Campus Streetscape, Buffalo, New York. Landscape Architect: SCAPE. Photo: nARCHITECTS Image: Google Street View, captured Jun 2026 Image: Google Street View, captured Jul 2019 Photo: 2xEDGE Werkspoorcampus, Utrecht, the Netherlands. Landscape Architect: Flux Landscape Architecture. Photo: Flux Landscape Architecture

• Oberrüti Sports Hall, Switzerland. Architect:

Page 19 (clockwise from top left):

•

Architect: Ene+Ene Arhitectura. Photo: Iulius Cristea Cargocenter Frankfurt. Architect: Kölling Architekten. Photo: Christoph Kraneburg Tech Forge, Lawrenceville, PA. Architect: Desmone Architects. Photo: Allen + Shariff Iowa City Public Works, Iowa City. Architect: Neumann Monson Architects. Photo: Integrated Studio

Page 26 (clockwise from top left):

• Unterfeld Energy Centre, Switzerland. • •

Page 23 (clockwise from top left):

• Royal Tichelaar Factory, Netherlands. • •

Architect: MONADNOCK. Photo: Stijn Bollaert Service and logistics center, Dresden, Germany. Architect: Code Unique Architects. Photo: Robert Gommlich Cortes Metalúrgicos Oviedo HQ, Valladolid, Spain. Architect: Óscar Miguel Ares Álvarez. Photo: Jesús J. Ruiz Alonso and Pedro Ivan Ramos Martín

Ohio. Artist: April Bleakney. Photo: Bob Perkoski Mural at 6917 Carnegie Avenue, Cleveland, Ohio. Artist: Ricky Watts. Photo: Bob Perkoski New Vimar Logistic Pole, Marostica, Italy. Architect: Alfonso Femia. Photo: Stefano Anzini

•

Architect: Lütjens Padmanabhan Architekt*innen. Photo: Philip Heckhausen ForD Warehouse, Hangzhou, China. Architect: SAY Architects. Photo: RAWVISION studio New Rousseau Métal factory, Québec, Canada. Architect: atelier guy. Photo: Dave Tremblay Cargocenter Frankfurt. Architect: Kölling Architekten. Photo: Christoph Kraneburg

Page 27 (clockwise from top left):

• Addition to Rice University Library Service Center, Houston, Texas. Architect: Carlos Jiménez Studio. Photo: Carlos Jiménez Studio

THE MIDLINE | Industrial Use Design Guidelines


• Ricola Storage Building, Switzerland. • •

Architect: Herzog & de Meuron. Photo: Christian Beutler / Keystone Aragon Grup Headquarters, Romania. Architect: Ene+Ene Arhitectura. Photo: Iulius Cristea Roshen Logistics Center, Ukraine. Architect: prototype. Photo: Yevhenii Avramenko

Page 29 (clockwise from top left):

• Ponce City Market, Atlanta, Georgia. • • • • • •

Architect: S9 Architecture. Photo: Garey Gomez Silver Spur Motel neon sign, Amarillo, Texas. Photo: Jason Burr Photography Blade sign for Yakabod, Frederick, MD. Photo: ShieldCo Hand-painted mural for Old Fourth Distillery, Atlanta, Georgia. Photo: @ Brett_Oliver / Instagram Image: Google Street View, captured Sep 2017 Pike Place Market neon sign, Seattle, Washington. Photo: @onegirlwholeworld / Instagram The Salt Shed at the Morton Salt complex, Chicago. Photo: Right Way Signs

Page 30 (clockwise from top):

• Howard Tenens Facility, Swindon, UK. Photo: Cladding Coatings

• Tree pit stormwater retrofit, the Netherlands. Photo: Hydrorock

• Photo: BŌK Modern • Photo: PalmSHIELD Page 31 (left to right):

• Image: Google Street View, captured May 2023

• Image: Google Street View, captured Jun 2026 Page 34 (back cover):

• Photo: Patrick Fenner

Photo Credits

33


Turn static files into dynamic content formats.

Create a flipbook