Kirlin's LED Medical Lighting Catalog 16MED2

Page 1

Bulletin 16MED2

Since 1895

Lighting Innovators

LED Medical Lighting Patient & Facility

Featuring: OPTeCOLOR™ (95+ CRI) LED, BioGard™, IP65 Trims,1 ISO 5 Class 100

INFRALED® • INFRALED® 60 • OPTe MED™ 3401 East Jefferson Avenue, Detroit MI 48207-4232 313-259-6400 • FAX: 313-259-3121 • www.kirlinlighting.com • info@kirlinlighting.com


Search by design and application Section

Application / Design

Page

Kirlin Expertise and Dependability Since 1895

4-5

Section I

SmartLED™ MRI Introduction and Section Table of Contents

6-9

SmartLED™ MRI Lighting Systems

Downlight and Sconce Lighting Systems: 1. Luminaires 2. Driver 3. Filter

Downlight, Adjustable and Wall Wash Luminaires

10-13

Sconces (ADA Compliant) and Luminaire Options

14

Remote Driver (Required)

15

RFI/EMI Filter (Required) Emergency Power Supply (Optional)

16-19

Room Configurations, Wiring Diagrams

20

Downlighting Design Guide and Checklist Scenic Panel (2 x 2 Configurable) Systems: 1. Luminaires 2. Driver 3. Filter

21-23

Scenic Panel Remote Driver (Required)

24

RFI/EMI Filter (Required)

25-27

Room Configuration, Checklist, Wiring Diagrams

Section II

Patient Exam Introduction and Section Table of Contents Lensed BioGard™ Antimicrobial Trim

Level 1 Infection Control

IP65 Rated Sealed Trim; Tamper Resistant

Level 2 and Level 2 + Infection Control

Motorized Patient Exam (With Remote & Wall Controls)

Section IV

IP65 ISO 5

Class 100 Sealed Fixture; Tamper Resistant Level 3 and Level 3 + Infection Control

Section III

rd

Ga

Bio

rd

Ga

Bio

IP65

CLASS

Patient Exam

28-29 30

rd

Ga

Bio

100

CLEANROOM

VR VR

31 32

Patient Exam Performance, Typical Installations, Options and Ordering Guide

33-35

Motorized Patient Exam Introduction and Section Table of Contents

36-37

OB and LDRP

INFRALED 60: Fully Recessed with Remote Control & Wall Control

38-39

ICU, CCU, PICU, NICU, ED, Cath Lab, OR Patient Room, Pathology

INFRALED®: Fully Recessed with Remote Control & Wall Control

40-41

OPTeMED : Fully Recessed with Wall Control

42-43

ShowerLights Introduction and Section Table of Contents

44-45

®

Gasketed Flare Trim - Non-Conductive

ShowerLights: Dead Front

46

IP65 Rated and Tamper Resistant Trim - Non-Conductive Super Shallow Housing and Gasketed Trim - Non-Conductive

(Non-Conductive)

Gasketed Drop Polycarbonate Trim - Non-Conductive

47

ShowerLight Options and Ordering Guide

Section V

48-49

General Lighting and Clinical Spaces Introduction and Section Table of Contents

50-51

Round and Square

IP65 Rated Sealed Trim; Tamper Resistant

Level 2 and Level 2 + Infection Control

Class 100 Sealed Fixture (Cleanroom)

Level 3 Infection Control, Sealed Fixture, BioGard™

IP65

rd

Ga

Bio

VR

51-52

ISO 5

rd

Ga

Bio

IP65

CLASS

General Lighting: Public and Clinical Spaces

Downlight, Wall Wash and Super Shallow

52

100

CLEANROOM

53

General Lighting and Clinical Space Options and Ordering Guide

Section VI

Scenic Panel (2 x 2 Configurable) Systems (for Non-MRI Use)

54-57

NightLights / ChartLights and StepLights Introduction and Section Table of Contents

58-59

NightLights / ChartLights

NightLights / ChartLights NightLights and StepLights

60

Inconspicuous (Round, Square, Rectangle) and Brick Light Single and Double Face

61

Maximum Security

(Type IC)

StepLight

62

Inconspicuous (Round, Square, Rectangle) and Brick Light

63

NightLight / ChartLight and StepLight Options and Ordering Guide

LUMINAIRE numbering LOGIC MRR-07500-5000L-120-30K-MFL

Options

Series

Voltage

M = Medical

Must Specify

Mount R = Recessed S = Surface N = NightLight

Page 2

Shape/Design R = Round S = Square T = Rectangle V = Vandal P = Panel (Scenic)

Lumen Series Must Specify

Size

Sequence in Catalog

Recessed Aperture Surface Diameter

www.kirlinlighting.com


Search by Number Product #

Description

Pg

first 3 characters alphabetically sorted: last 5 characters numerically Product #

Description

Pg

Product #

Backup Power MRI

15

MRR-05825-2500L

Patient Room

51

MRR-08835-3500L

Backup Power Exam

35

MRR-06205-1500L

MRI

10

MRR-08835-2500L

LPS-0700A

Remote Driver MRI

24

MRR-06230-1500L

Remote Driver MRI

15

MRR-06235-1500L

MRI

11

LPS-1220A

Remote Driver Exam

35

MRR-06420-2500L

Remote Driver General

53

MRR-06422-2500L

MNR-05900

NightLight/ChartLight

60

MRR-06424-2500L

MNR-05920

StepLight

62

MRR-06426-2500L

MNS-05904

NightLight/ChartLight

60

MRR-06427-2500L

MNS-05924

StepLight

62

MRR-06705-1500L

NightLight/ChartLight

60

EMI-21220

MNT-03906 MNT-03908 MNT-03926 MNT-03928

StepLight

62

MNT-07912 MNT-07914

NightLight

61

MNV-07916

MRR-06705-1000L MRR-06705-500L

MRP-22295

Scenic Panel

54

MRR-06810-2500L

MRI

10

MRR-06815-3500L

12

MRR-06815-2500L

MRR-04700-2500L

MRR-07240-1500L

46

MRR-04720-500L

40

MRR-12642

Motorized Exam OPTeMED™

42

MRS-04245-1500L

MRI

11

Patient Room

50

MRS-08470-2500L

MRI

13

MRS-17600

Birthing INFRALED® 60

38

Patient Exam

30

Patient Exam

32

Shower

46

Patient Room

52

Patient Exam

31

Patient Exam

32

Patient Room

52

MRI Cylinder

13

MRI Sconce

14

RFI/EMI MRI Filter

15 24

MRR-12620 MRR-12622

MRI

Shower

13

46

Patient Room

50

MRR-06815-5000L

MRR-04225-1500L

MRR-04720-1000L

MRI

MRR-12640

MRS-04803-1500L MRS-04803-1000L

MRS-04804-1000L

MRR-06810-3500L

Shower

Motorized Exam INFRALED®

MRR-08855-2500L

MRR-06805-3500L

21

MRR-04720-1500L

52

MRR-08855-3500L

MRS-04804-1500L

MRI Scenic Panel

MRR-04200-1500L

Patient Room

MRR-08855-5000L

MRR-06805-5000L

MRP-22290

MRR-04220-1500L

51

MRS-04803-500L

MRR-06810-5000L

MRR-07505-5000L

MRS-04804-500L

MRT-04510-5000L Patient Room

51

MRT-05515-7000L MRT-05515-5000L

MRI

11

MRR-07500-5000L MRR-07500-3500L

MRV-07560-1500L MRV-07715-1500L

Patient Exam

30

MRV-07715-1000L MRV-07715-500L

MRR-04800-1500L

MRR-07505-3500L

MRR-04800-1000L

MRR-07550-1500L

Patient Exam

32

MRV-08540-5000L

MRR-04800-500L

MRR-07830-1500L

Patient Room

51

MRV-08540-3500L

MRR-07850-1500L

Patient Room

52

MRV-08545-5000L

MRR-04802-1000L

MRR-08428-2500L

MRI

13

MRV-08545-3500L

MRR-04802-500L

MRR-08530-5000L

MRV-08565-5000L

MRR-04820-1500L

MRR-08530-3500L

MRV-08565-3500L

MRR-04802-1500L

MRR-04820-1000L

Patient Room

50

Patient Room

51

Shower

46

MRR-04820-500L MRR-05725-2500L MRR-05730-1500L MRR-05730-1000L MRR-05730-500L

MRR-08535-5000L

Shower

MRR-05735-2500L

47

MRV-07840-1500L

Patient Exam

31

MRV-08845-5000L

MRR-08535-3500L

MRV-08845-3500L

MRR-08555-5000L

MRV-08845-2500L

MRR-08555-3500L MRR-08558-5000L

Patient Exam

32

MRR-08558-3500L MRR-08835-5000L

Pg

Patient Room

MRR-06710-2500L

MRR-06805-2500L

Description

MSR-12440-2500L MSR-14250 MSS-10255

Patient Room

51

RFI-3100D

MAGNIFYING GLASS ICON (FOUND THROUGHOUT CATALOG) INDICATES TABLE OF CONTENTS PLEASE VISIT www.kirlinlighting.com FOR: KIRLIN MEDICAL LIGHTING PRODUCTS WITH OTHER LIGHT SOURCES IN KIRLIN’S PATIENT EXAM & HEALTHCARE LIGHTING CATALOG (BULLETIN 08HC) AND KIRLIN’S COMPLETE COLLECTION OF LED LUMINAIRES IN KIRLIN’S LATITUDES LED LIGHTING CATALOG (BULLETIN 15/16LED).

www.kirlinlighting.com

Page 3


Kirlin Expertise and Dependability since 1895 A SAFER ENVIRONMENT FOR PATIENTS AND STAFF oG

Bi

d™ ar

IP65 ISO 5 CLASS

• Fully recessed fixtures provide an open work space. • IP65 rated sealed trims and ISO 5 Class 100 rated sealed fixtures provide optimal protection against pathogen transmission through luminaires. • BioGard™ antimicrobial trim finish inhibits survival of pathogens. • Compact and smooth trims, lenses and controls are easy to clean and disinfect. • Dead-front (non-conductive) shower trims protect patients and staff. • Attractive, inconspicuous vandal resistant designs ideal for ED, psychiatric units and public spaces.

100

CLEANROOM

BioGard™ antimicrobial finish inhibits the growth of infectious microbes on luminaire trims. IP65 rated sealed and gasketed trims prevent dust and sprayed liquids from entering the fixture through the trim/lens assembly. ISO 5 Class 100 Cleanroom rated sealed fixtures prevent particles larger than 5 microns from passing through the fixture.

HIGHER QUALITY LIGHT For more accurate diagnosis and improved visual acuity

KIRLIN OPTeCOLOR™ LED

Common CRI

• High color rendering LEDs assure accurate tissue color rendering: 95+ CRI with excellent R9 (Red), R13 and R15 (Skin Colors) • Ideal color temperatures for specific tasks: 3500K (Neutral white: Standard), 3000K (Warm white: Option -30K), 4100K (Cool white: Option -41K) or 5000K (Daylight white: Option -50K). • Up to 9000 footcandles are provided for the most demanding and intricate medical procedures. • -SPT, -NFL, -MFL and -WFL distributions available.

High CRI

GREATER CONTROL FOR IMPROVED CARE • Kirlin delivers dimmable light from multiple sources, at proper angles, with optimal light levels to reduce shadows and illuminate clinicians’ line of site. • Intuitive and responsive controls for our motorized lighting systems provide quick and accurate adjustment of direction and intensity of the light. • Dimming down to 10% (and 0.2% for MRI lighting systems) permits staff to finely tune light levels for specific tasks, each clinician and time of day. • SmartSupply™ MRI lighting system remote driver controls up to twelve fixtures with 3 zones of dimming.

Page 4

www.kirlinlighting.com


Kirlin Expertise and Dependability since 1895

GREATER COMFORT FOR PATIENT AND STAFF • LED does not project heat toward the room environment, assuring patient and practitioner comfort while avoiding tissue desiccation. • SmartLED™ Scenic Panels create a soothing, attractive, and more natural environment to reduce patient stress, promoting the healing process. • Inconspicuous: Fully recessed fixtures provide a more residential atmosphere; motorized lighting systems’ controls do not invade patient’s personal space. • INFRALED® Series’ remote controls use invisible infrared signals to prevent unintended consequences, such as migraines and photosensitive epileptic seizures. • Red/Amber (Option -RA) NightLights maintain patients’ melatonin levels and proper circadian rhythm, ensuring restful nights and time for healing.

REDUCED OPERATING COSTS

ARRA

QUALIFIED

IC

• Long LED life, up to 90,000 hours (L70), results in 90 fewer lamp changes over the life of the system. • Corrosion resistant all-aluminum construction extends every components’ life by 50% due to operating 25% cooler. • Power consumption is typically only 20% of traditional light sources. • Fully sustainable. Modular, internal components are visible and easily accessed through the aperture of the fixture. Lighthead may be inexpensively updated to change spacing criteria, light level and color temperature. • Luminaires are designed for multiple lumen packages, allowing the specifier to select the most energy efficient solution for each application. • LEDs produce up to 80% less heat than traditional light sources, significantly reducing the load on hospital HVAC systems. • Shallow and super shallow recessed housings fit easily in crowded plenums. • Type IC standard on most models including all MRI luminaires, all -1500L/ -1000L/-500L luminares and all NightLights, StepLights and ChartLights.

Designed and Produced in U.S.A. • UL, C-UL (Canada) Listed www.kirlinlighting.com

Page 5


SECTION I: SmartLED™ MRI - THE turnkey KIRLIN SYSTEM SmartLED™ NON FERROMAGNETIC luminaires • Award winning 1500 lumen and 2500 lumen ambient downlights, adjustable task lighting and wall washes. Wall sconces and surface mount available. • Up to 4 spacing criteria available: From 0.3 (SPT) for task lighting to 1.1 (WFL) for ambient lighting. 2011 Architectural SSL Product Innovation Award

SmartLED™ Scenic Panels • Beautiful photography or custom art with soothing back lighting in 2x2 recessed panels with flared reveal. • Creates a calming environment to reduce patient stress and assist in the healing process. • Limitless configurations available to maximize impact and match the unique dimensions of each suite.

SmartSupply™ remote driver 2011 IES Progress Report Selections

• Controls up to twelve fixtures (1500L Series) or twelve Scenic Panels or six fixtures (2500L Series). • Dims to 0.2% permitting finely tuned light levels. • 3 zones of dimming for luminaires. • Conveniently mounted outside the shield

SmartFilter™ RFI/EMI filter • PROVEN to work with MRI equipment (up to 7 Tesla) from all of the major manufacturers. • Industry leading RFI/EMI protection. • Superior insertion loss of 100dB (minimum) • Easily installed on exterior surface of shield Page 6

www.kirlinlighting.com


SECTION I: SmartLED™ MRI LUMINAIRE SYSTEM Design

Function

Aperture (Inches)

Product #

Performance Lumens

Watts

1500 LUMEN MRI Downlight, Adjustable and Wall Wash luminaires

Page 10-11

Open Appearance

Downlight

4

MRR-04200-1500L

1500

20

Open Appearance

Downlight

6

MRR-06205-1500L

1500

20 10

Open Appearance

Adjustable

4

MRR-04220-1500L

1500

20

Open Appearance

Wall Wash

4

MRR-04225-1500L

1500

20

Flare with Regressed Lens

Downlight

6

MRR-06230-1500L

1500

20

Flare with Regressed Lens

Downlight

6

MRR-06235-1500L

1500

20 11

IP65 Infection Control

Downlight

7

MRR-07240-1500L

1500

20

Square Flare with Regressed Lens

Downlight

4

MRS-04245-1500L

1500

20

MRI Sconces - ADA COMPLIANT - only 2½” protrusion from wall Round Center Field Edge Glow

Sconce

14

14

MSR-14250

20 14

Square Center Field Edge Glow

Sconce

10

MSS-10255

20

SmartLED™ MRI Table of Contents - continued on pages 8-9

PLEASE VISIT www.kirlinlighting.com FOR KIRLIN INCANDESCENT MRI LIGHTING PRODUCTS IN KIRLIN’S PATIENT EXAM & HEALTHCARE LIGHTING CATALOG (BULLETIN 08HC).

www.kirlinlighting.com

Page 7


SECTION I: SmartLED™ MRI LUMINAIRE SYSTEM Design

Function

Aperture (Inches)

Product #

Performance Lumens

Watts

2500 Lumen MRI Downlight, Adjustable and Wall Wash LUMINAIRES

Page 12-13

Open Appearance Lensed

Downlight

6

MRR-06420-2500L

2500

35

Open Appearance Lensed

Adjustable

6

MRR-06422-2500L

2500

35

Open Appearance Lensed

Wall Wash

6

MRR-06424-2500L

2500

35

Flare with Regressed Lens

Downlight

6

MRR-06426-2500L

2500

35

Flare with Regressed Lens

Downlight

6

MRR-06427-2500L

2500

35

IP65 Infection Control

Downlight

8

MRR-08428-2500L

2500

35

Surface Mount Flat Trim

Downlight

12

MSR-12440-2500L

2500

35

K-Lens Recessed Square

Downlight

8

MRS-08470-2500L

2500

35

LUMINAIRE and sconce SYSTEM COMPONENTS

12

13

14

Required For Luminaires

SmartSupply™ (1400mA)

Remote Driver

LPS-1220A

Required For Luminaires

SmartFilter™

RFI/EMI Filter

RFI-3100D

Optional For Luminaires

SmartPower™ (Optional)

Emergency Power Supply

EMI-21220

15

DOWNLIGHTING typical SYSTEM configuration and Photometric Performance

16

Typical System Configurations FOR DOWNLIGHTING

17

Typical Wiring Overview and Wiring Diagram for luminaires

18-19

DOWNLIGHTING luminaire system Design Guide and Checklist

20

PLEASE VISIT www.kirlinlighting.com FOR KIRLIN INCANDESCENT MRI LIGHTING PRODUCTS IN KIRLIN’S PATIENT EXAM & HEALTHCARE LIGHTING CATALOG (BULLETIN 08HC).

Page 8

www.kirlinlighting.com


SECTION I: SmartLED™ MRI SCENIC PANEL SYSTEM Design

Function

Aperture (Inches)

Product #

24

MRP-22290

Scenic Panel: 2’x2’ Building Block Configuration

Performance Watts

20

Page

21

SCENIC PANEL IMAGES

22

SCENIC PANEL CONFIGURATIONS & product specification guide

23

Required For SmartSupply™ (700mA) Scenic Panels

Remote Driver

LPS-0700A 24

Required For SmartFilter™ Scenic Panels

RFI/EMI Filter

RFI-3100D

TYPICAL SYSTEM CONFIGURATION FOR SCENIC PANELS & SCENIC PANEL CHECKLIST Typical Wiring Overview and Wiring Diagram for SCENIC PANELS

25 26-27

SECTION I: SmartLED™ MRI SCENIC PANEL SYSTEM

SmartLED™ Scenic Panels • Beautiful photography or custom art with soothing back lighting in 2x2 recessed panels with flared reveal. • Creates a soothing environment to reduce patient stress and assist in the healing process. • Configurable overall size to suit the unique dimensions of each MRI suite.

www.kirlinlighting.com

Page 9


MRI LUMINAIRE SYSTEM: 1500 Lumen Series (-1500L)

IC

4” PERFORMANCE (-1500L Series) 1538 LUMENS 20W MFL (std) SC: 0.8

Downlights

LPW: 74

90˚ 75˚

800

60˚

1600 2400 0˚

45˚ 15˚

30˚

Cone of Light ▲ Dist.

FC

Dia.

6 8 10 12 14 16

64.9 36.5 23.4 16.2 11.9 9.1

4.9 6.6 8.2 9.9 11.5 13.2

-SPT

-NFL

Lm: 1629 SC: 0.3

Lm: 1428 SC: 0.6

-SPT

-NFL

Lm: 1706 SC: 0.3

Lm: 1588 SC: 0.6

-SPT

-MFL

Lm: 1566 SC: 0.4

Lm: 1557 SC: 0.8

MRR-04200-1500L

6” PERFORMANCE (-1500L Series) 1670 Lumens 20W MFL (std) SC: 0.8 LPW: 80

90˚ 75˚

850

60˚

1700 2550 0˚

45˚ 15˚

30˚

Cone of Light ▲ Dist.

FC

Dia.

6 8 10 12 14 16

67.2 37.8 24.2 16.8 12.3 9.4

5.0 6.7 8.3 10.0 11.6 13.3

MRR-06205-1500L

4” PERFORMANCE (-1500L Series)

Adjustable

1564 Lumens 20W

2000

NFL (std)

4000

SC: 0.5 LPW: 75

MRR-04220-1500L

90˚

6000 0˚

75˚ 60˚ 45˚ 15˚

30˚

2011 Architectural SSL Product Innovation Award

4” PERFORMANCE (-1500L Series)

Wall Wash

90˚

1375 Lumens 20W LPW: 66

75˚

550

60˚

1100 1650 0˚

45˚ 15˚

30˚

▲ Cone of Light Key

Ft. Distance from fixture FC Footcandles at nadir (0°) Dia. Circle of light at 50% of FC Dia. (in ft.) shown is where FC value is half the FC at nadir.

MRR-04225-1500L

Use of both Kirlin SmartSupply™ LPS-1220A (1400mA) and SmartFilter™ RFI-3100D are required to maintain Kirlin warranty. Page 10

www.kirlinlighting.com


MRI LUMINAIRE SYSTEM: 1500 Lumen Series (-1500L) 6”

PERFORMANCE (-1500L Series) 1721 Lumens 20W MFL (std) SC: 0.8

Lensed Downlights

IC

LPW: 83

90˚ 75˚

800

60˚

1600 2400 0˚

45˚ 15˚

30˚

Cone of Light ▲ Dist.

FC

Dia.

6 8 10 12 14 16

67.3 37.8 24.2 16.8 12.4 9.5

4.9 6.6 8.2 9.9 11.5 13.2

-SPT

-NFL

-WFL

Lm: 1744 SC: 0.3

Lm: 1553 SC: 0.6

Lm: 1514 SC: 1.1

-SPT

-NFL

-WFL

Lm: 1744 SC: 0.3

Lm: 1553 SC: 0.6

Lm: 1514 SC: 1.1

-SPT

-NFL

-WFL

Lm: 1744 SC: 0.3

Lm: 1553 SC: 0.6

Lm: 1514 SC: 1.1

MRR-06230-1500L

6”

PERFORMANCE (-1500L Series) 1721 Lumens 20W MFL (std) SC: 0.8 LPW: 83

MRR-06235-1500L

90˚ 75˚

800

60˚

1600 2400 0˚

45˚ 15˚

30˚

Cone of Light ▲ Dist.

FC

Dia.

6 8 10 12 14 16

67.3 37.8 24.2 16.8 12.4 9.5

4.9 6.6 8.2 9.9 11.5 13.2

2011 Architectural SSL Product Innovation Award

7”

IP65 Downlight

PERFORMANCE (-1500L Series) 1721 Lumens 20W MFL (std) SC: 0.8 LPW: 83

MRR-07240-1500L

IP65

90˚ 75˚

800

60˚

1600 2400 0˚

45˚ 15˚

30˚

Cone of Light ▲ Dist.

FC

Dia.

6 8 10 12 14 16

67.3 37.8 24.2 16.8 12.4 9.5

4.9 6.6 8.2 9.9 11.5 13.2

™ rd

Ga

Bio

4”

Lensed Downlight

PERFORMANCE (-1500L Series) 1606 Lumens 20W MFL (std) SC: 0.8 LPW: 76

90˚ 75˚

800

60˚

1600 2400 0˚

45˚ 15˚

30˚

Cone of Light ▲ Dist.

FC

Dia.

6 8 10 12 14 16

67.8 38.1 24.4 16.9 12.4 9.5

4.7 6.3 7.8 9.4 11.0 12.5

-NFL

Lm: 1589 SC: 0.5

MRS-04245-1500L

Use of both Kirlin SmartSupply™ LPS-1220A (1400mA) and SmartFilter™ RFI-3100D are required to maintain Kirlin warranty. www.kirlinlighting.com

Page 11


MRI LUMINAIRE SYSTEM: 2500 Lumen Series (-2500L)

IC

6” PERFORMANCE (-2500L Series)

Downlight

3058 Lumens 35W MFL (std) SC: 0.8 LPW: 87

90˚ 75˚

1500

60˚

3000 4500 0˚

45˚ 15˚

30˚

Cone of Light ▲ Dist.

FC

Dia.

6 8 10 12 14 16

114.3 64.3 41.2 28.6 21.0 16.1

5.1 6.8 8.5 10.2 11.9 13.6

-SPT

-NFL

Lm: 3168 SC: 0.3

Lm: 2922 SC: 0.6

-SPT

-MFL

Lm: 3008 SC: 0.3

Lm: 2997 SC: 0.8

MRR-06420-2500L

6” PERFORMANCE (-2500L Series)

Adjustable

2732 Lumens

90˚

35W

2000

NFL (std)

4000

SC: 0.6 LPW: 78

6000 0˚

75˚ 60˚ 45˚ 15˚

30˚

MRR-06422-2500L

6” PERFORMANCE (-2500L Series)

Wall Wash

90˚

2772 Lumens

1000

35W

2000

LPW: 79

3000 0˚

75˚ 60˚ 45˚ 15˚

▲ Cone of Light Key

Ft. Distance from fixture FC Footcandles at nadir (0°) Dia. Circle of light at 50% of FC Dia. (in ft.) shown is where FC value is half the FC at nadir.

30˚

MRR-06424-2500L

Use of both Kirlin SmartSupply™ LPS-1220A (1400mA) and SmartFilter™ RFI-3100D are required to maintain Kirlin warranty. Page 12

www.kirlinlighting.com


MRI LUMINAIRE SYSTEM: 2500 Lumen Series (-2500L) PERFORMANCE (-2500L Series)

6” 2993 Lumens 35W

Lensed Downlights

MFL (std) SC: 0.8 LPW: 81

MRR-06426-2500L

75˚

1250

60˚

2500 3750 0˚

45˚ 15˚

2993 Lumens

MFL (std) SC: 0.8 LPW: 81

MRR-06427-2500L

90˚ 75˚

1250

60˚

2500 3750 0˚

45˚ 15˚

3030 Lumens 35W MFL (std) SC: 0.8

Surface Downlight

MRR-08428-2500L

Lensed Downlight

Dist.

FC

Dia.

6 8 10 12 14 16

109.0 61.6 39.4 27.4 20.1 15.4

5.0 6.7 8.4 10.0 11.7 13.4

-NFL

-WFL

Lm: 2888 SC: 0.5

Lm: 2379 SC: 1.0

30˚

Cone of Light ▲

-NFL

-WFL

Dist.

FC

Dia.

6 8 10 12 14 16

109.0 61.6 39.4 27.4 20.1 15.4

5.0 6.7 8.4 10.0 11.7 13.4

Lm: 2888 SC: 0.5

Lm: 2379 SC: 1.0

PERFORMANCE (-2500L Series)

8”

8”

30˚

Cone of Light ▲

PERFORMANCE (-2500L Series)

35W

IP65 Downlight

90˚

6”

12”

IC

IP65

G

Bio

d™ ar

LPW: 82

90˚ 75˚

1250

60˚

2500 3750 0˚

45˚ 15˚

30˚

Cone of Light ▲ Dist.

FC

Dia.

6 8 10 12 14 16

110.0 61.7 39.5 27.4 20.2 15.4

4.9 6.6 8.2 9.9 11.5 13.1

-NFL

Lm: 3010 SC: 0.5

PERFORMANCE (-2500L Series) 3147 Lumens 35W

90˚ 75˚

1150

60˚

2300

SC: 0.8

MSR-12440-2500L

LPW: 89

3450 0˚

45˚ 15˚

30˚

Cone of Light ▲ Dist.

FC

Dia.

6 8 10 12 14 16

103.0 58.1 37.2 25.8 19.0 14.5

4.9 6.6 8.2 9.7 11.5 13.2

PERFORMANCE (-2500L Series) 2693 Lumens 35W WFL (std) SC: 1.2

MRS-08470-2500L

LPW: 76

Cone of Light ▲ 0

90˚ 75˚

330

60˚

660 990 0˚

45˚ 15˚

30˚

Dist.

FC

Dia.

6 8 10 12 14 16

28.4 16.0 10.2 7.1 5.2 4.0

7.1 9.5 11.9 14.3 16.6 19.0

▲ Cone of Light Key

Ft. Distance from fixture FC Footcandles at nadir (0°) Dia. Circle of light at 50% of FC Dia. (in ft.) shown is where FC value is half the FC at nadir.

Use of both Kirlin SmartSupply™ LPS-1220A (1400mA) and SmartFilter™ RFI-3100D are required to maintain Kirlin warranty. www.kirlinlighting.com

Page 13


MRI sconce SYSTEM: ADA COMPLIANT - 2½” from the wall LED Light Engine

Brushed Anodized Aluminum Housing

• 1300 lumen, 20 watt LED array • 3500°K CCT standard • 90,000 hours (L70) • Fully sustainable: Removable for servicing

• 2 ½” depth meets all ADA requirements • All aluminum construction maximizes cool operation and component life • Optional housing and faceplate finishes

Sconce Assembly

• Decorative brushed aluminum faceplate and housing with clear 1/4” acrylic diffuser • Illuminated center field and edge glow.

Installation

• Wall or ceiling mount • Universal back plate mounts to any non-ferromagnetic octagon or 4” square J-box (provided by others).

MSR-14250

MSS-10255

Red Wing Red Option -RE

Circadian Red / Amber Option -RA

Tiger Orange Option -OR

Wolverine Maize Option -YE

Spartan Green Option -GN

Lion Blue Option -BL

Custom Image / Logo Option -CI

Use of both Kirlin SmartSupply™ LPS-1220A (1400mA) and SmartFilter™ RFI-3100D are required to maintain Kirlin warranty.

POPULAR LUMINAIRE and Sconce Options DOWNLIGHTS Input Power: SPECIFY -120 120V (50-60Hz) input. -277 277V (50-60Hz) input. -97 Specify other voltage. Consult factory.

Color Temperature (CCT) -27K -30K -41K -HC

Color temperature 2700°K instead. Color temperature 3000°K instead. Color temperature 4100°K instead. 90+ CRI instead. Use with Option -27K or -30K only. Reduces output by ~15%.

Optics -NFL Narrow flood distribution. -SPT Spot distribution. -WFL Wide flood distribution.

Lenses & Trims -13 -17 -21

Vandal resistant dual lens system: prismatic high strength acrylic above, clear poly below, instead of standard lens. .187” prismatic high strength acrylic lens instead. Also see Option -26. White translucent flat poly diffuser instead.

Page 14

SCONCES -23 -26

Frosted microprismatic lens instead. Tamper-resistant button head recessed hex screw with center pin and 1 key / 10 fixtures. -30 All white acrylic enameled cone. -31 White acrylic enameled flange (only) on cone. -32 White oversize trim ring. Specify O.D. -45 Gasket between trim flange and ceiling. -46 Gasket between trim and lens. -70 SofTex Clear self-flanged cone. (CP x .95) -94 Custom color/finish. Specify. Consult factory. -BG Antimicrobial Kirlin BioGard™ white (only) trim finish. -WA White acrylic (flat) diffuser instead.

Surface Housing Finishes -35 -38 -94

(White Standard)

Natural aluminum (silver) acrylic enamel. Black acrylic enamel. Custom color. Specify. Consult factory.

Other -79 -99

Faceplate & Housing -30 -38 -94 -BG

White baked enamel finish instead. Black baked enamel finish instead. Custom color/finish. Specify. Consult factory. Antimicrobial Kirlin BioGard™ white (only) finish.

Colors: Center Field & Edge Glow -BL -CF -GN -OR -RA -RE -YE

Blue (filter). Custom (filter) color (Rosco). Specify. Green (filter). Orange (filter). Red amber (filter). Red (filter). Yellow (filter).

Other -CI

Custom image (color/logo) in center field of sconce.

Extension collar for up to 2” thick ceilings. Special modification. Consult factory.

(See specification sheets for availability and details.) www.kirlinlighting.com


MRI SmartSupply™ REMOTE DIMMING DRIVER - REQUIRED • Full range 100% to 0.2% dimming and 3 dimming zones. See page 18 or consult factory for compatible controls. • Over wattage, cross channel, and electrical fast transient (EFT) protection. • Mounted outside MRI shield (not directly to shield). • Input: 115-277VAC / 50-60Hz rated. Dedicated 120VAC input recommended. For 277VAC input, proper line filtering and surge protection must be provided (by others). Maximum continuous input voltage is 290VAC. • Requires 16 AWG (minimum) twisted pair shielded wire from SmartSupply™ to luminaires. • FIVE YEAR Limited Warranty.

LPS-1220A

2011 IES Progress Report Selection

With 1500 Lumen Series (-1500L) SmartLED™ Luminaires

(6) Channels (Circuits) Maximum Distance Per Channel

With 2500 Lumen Series (-2500L) SmartLED™ Luminaires

Up to (2) luminaires / channel

(1) luminaire / channel

Up to (12) luminaires / SmartSupply™

Up to (6) luminaires / SmartSupply™

(1) luminaire / channel: 150 feet

(1) luminaire / channel: 150 feet

(2) luminaires / channel: 50 feet *

*Distance to the farthest fixture

SmartFilter™ DC RFI / EMI FILTER - REQUIRED

2011 IES Progress Report Selection

RFI-3100D

• Industry leading RFI and EMI protection • Superior insertion loss of 100 dB (min.) • Fully protects 20 kHz to 1.0 GHz • One filter protects up to three SmartSupply™ channels • Up to two filters required per SmartSupply™ • Mounted on outside surface of MRI shield • FIVE YEAR Limited Warranty

SmartPower™ EMERGENCY BACKUP SYSTEM - OPTIONAL • High efficiency pure sine wave inverter • Operates up to two fully loaded SmartSupply™ drivers • 100% light output for up to 2 hours • 120 / 277V, 60Hz input • May be mounted up to 1000 feet from load

• Less than 0.05 seconds transfer time • UL 924 Listed. Meets or exceeds all NEC and Life Safety Code Emergency Lighting Requirements • THREE YEAR Limited Warranty. SEVEN YEAR pro-rata battery warranty

EMI-21220

MRI SYSTEM ORDERING EXAMPLE Quantity

Product

Description

12

MRR-06205-1500L-120V-41K-WFL

Luminaires

1

LPS-1220A

SmartSupply™ (1400mA) driver (required)

2

RFI-3100D

SmartFilter™ DC RFI/EMI filter (required)

www.kirlinlighting.com

Page 15


MRI LUMINAIRE SYSTEM: TYPICAL CONFIGURATION

Photo courtesy of Haselden Construction 6' - 10"

22' - 8"

MRI Room

14' - 6"

Equipment Room (1) EMI-21220

6' - 6"

Zone 3 45 fc Zone 2 85 fc

(4) RFI-3100D

(2) LPS-1220A

MRI

Control Room

Zone 1 100 fc

MRI Shield

19' - 9"

Typical MRI Suite Lighting Zones and Component Locations

0-10VDC Dimmer

PRODUCTS Product Type

Product #

Qty

Location

Adjustable Task Lighting

MRR-06424

4

Over the transfer table

Fixed Ambient Downlights

MRR-06426

8

Perimeter of MRI room

Remote Drivers

LPS-1220A

2

Outside the MRI shield

EMI/RFI Filters

RFI-3100D

4

On the MRI shield

Emergency Inverter

EMI-21220

1

Outside the MRI shield

0-10VDC Dimmers

See page 26

2

In the control room

Page 16

PHOTOMETRIC performance Zone

Location

fc

1

Transfer Table

100

2

Near Transfer Table

85

3

MRI Perimeter

45

Luminaires Product #

Qty

MRR-06424

4

MRR-06426

8

www.kirlinlighting.com


MRI LUMINAIRE SYSTEM: Typical Configurations 1500 Lumen (20W) Luminaires RFI / EMI Shield Kirlin SmartLED™ Luminaire

• Up to (12) 20W luminaires per SmartSupply • Up to (2) luminaires per SmartSupply channel (circuit). • Each color represents (1) set of (3) channels Kirlin SmartFilter™ RFI-3100D (Required) • (1) filter protects up to (3) SmartSupply channels. Each color represents (1) set of (3) channels • Up to (2) filters required per SmartSupply • Mounted on outside surface of MRI shield Kirlin SmartSupply™ LPS-1220A (Required) • (6) channels -- Up to (2) luminaires per channel -- Up to (12) luminaires per SmartSupply • Max distance per channel -- 150’ with (1) luminaire per channel -- 50’ with (2) luminaires per channel • Mounted outside MRI shield (not directly to shield) Kirlin SmartPower™ EMI-21220 (Optional) • Max distance from load: 1000’ • Mounted outside MRI shield (not directly to shield)

2500 Lumen (35W) Luminaires RFI / EMI Shield Kirlin SmartLED™ Luminaire

• Up to (6) 35W luminaires per SmartSupply • (1) luminaire per SmartSupply channel (circuit). • Each color represents (1) set of (3) channels Kirlin SmartFilter™ RFI-3100D (Required) • (1) filter protects up to (3) SmartSupply channels. Each color represents (1) set of (3) channels • Up to (2) filters required per SmartSupply • Mounted on outside surface of MRI shield Kirlin SmartSupply™ LPS-1220A (Required) • (6) channels -- Up to (1) luminaire per channel -- Up to (6) luminaires per SmartSupply • Max distance per channel: -- 100’ with (1) luminaire per channel • Mounted outside MRI shield (not directly to shield) Kirlin SmartPower™ EMI-21220 (Optional) • Max distance from load: 1000’ • Mounted outside MRI shield (not directly to shield)

www.kirlinlighting.com

Page 17


MRI LUMINAIRE SYSTEM: Typical Wiring Overview This wiring overview provides dimming control for zones 1, 2 and 3 simultaneously with a 0-10V DC dimmer* connected to the master 0-10V DC input of the SmartSupply™.

Shown with: • • • • •

Use of both Kirlin SmartSupply (1400mA) and SmartFilter are required to maintain Kirlin warranty.

(1) SmartSupply™ LPS-1220A (2) SmartFilters™ RFI-3100D (6) 1500 Lumen Series (20W) Luminaires (3) 2500 Lumen Series (35W) Luminaires (1) Wall Box Dimmer*

Requires 16 AWG (minimum) twisted pair shielded wire from SmartSupply (1400mA) to luminaires.

CHANNELS 5, 6

JUNCTION BOX

SmartSupply™ LPS-1220A (Output)

SmartFilter™

SmartFilter™

RFI-3100D

RFI-3100D

GREY

CHANNEL 6

CHANNEL 5

CHANNEL 4

CHANNEL 3

SmartSupply™ LPS-1220A (Input)

CHANNEL 2

CHANNEL 1

PURPLE

CHANNELS 5, 6

CHANNELS 3, 4

CHANNELS 3, 4

CHANNELS 1, 2

CHANNELS 1, 2

2500L (35W) Luminaires

WALL BOX DIMMER*

LINE

1500L (20W) Luminaires

AC INPUT

NEUTRAL

Wall dimmer must be mounted OUTSIDE of room shield. Dimming control wires MUST NOT connect through the filter.

* Kirlin recommends using the following compatible 0-10V DC dimmers: Leviton

Lightolier

Acuity

IP710-DLX ZP600FAM-XXX

Sunrise

MP1500FAM-XXX

Momentum

V2000FAMU

Vega

ISD BC

Lutron

NFTV **

Nova

NTSTV-DV **

Nova T

DVTV

Diva

DVSTV **

Diva

V-600

w/GRX-TVI

Vareo

** WARNING! WHEN USING LUTRON NFTV OR NTSTV-DV LOW-VOLTAGE 0-10V DIMMERS, DO NOT SPECIFY OR INSTALL LUTRON PP-SERIES POWER PACKS. USE OF PP-SERIES POWER PACKS MAY CAUSE DAMAGE TO THE SmartSupply™ THAT IS NOT COVERED UNDER WARRANTY.

Page 18

www.kirlinlighting.com


MRI LUMINAIRE SYSTEM: Wiring Diagram

BLACK (-)

BLACK (–) CH 3

INSIDE MRI ROOM

RED (+) CH 3

Wire shields INSIDE room MUST be connected to room shield grounding bar.

BLACK (–) CH 1

DO NOT CONNECT wire shields to the luminaires.

BLACK (–) CH 2

RED (+)

Requires 16 AWG twisted pair shielded wire from SmartSupply (1400mA) to luminaires.

RED (+) CH 1

RED (+) CH 6

BLACK (–) CH 6

BLACK (-)

RED (+)

BLACK (–) CH 5

RED (+) CH 5

BLACK (–) CH 4

RED (+) RED (+) CH 4

BLACK (-)

Use of both Kirlin SmartSupply (1400mA) and SmartFilter are required to maintain Kirlin warranty.

One 1500 or 2500 Lumen Series (20W or 35W) Luminaire on One Circuit

RED (+) CH 2

DO NOT CONNECT LED luminaires to energized driver.

Two 1500 Lumen Series (20W) Luminaires on One Circuit

ROOM SHIELD GROUNDING BAR

ROOM SHIELD

GREEN (–) CH 3

WHITE (+) CH 3

BLACK (–) CH 2

DO NOT CONNECT wire shields OUTSIDE room to room shield grounding bar.

RFI-3100D

RED (+) CH 2

Requires 16 AWG twisted pair shielded wire from SmartSupply (1400mA) to luminaires.

WHITE (+) CH 1

BLACK (–) CH 6

RED (+) CH 6

GREEN (–) CH 5

WHITE (+) CH 5

BLACK (–) CH 4

RFI-3100D

RED (+) CH 4

SmartFilter™

OUTSIDE MRI ROOM

GREEN (–) CH 1

SmartFilter™

Electrical Input: 115-277VAC / 50-60Hz isolated circuit only. Maximum input voltage 290V.

ZONE 4 (NOT USED)

ZONE 1

ZONE 3

ZONE 2

SmartSupply™ LPS-1220A*

* DO NOT MOUNT OR CONNECT SmartSupply (1400mA) to room shield.

For more information on Kirlin’s SmartLED™ MRI lighting systems, including specification sheets and owner’s manuals (including installation instructions and wiring diagrams), please visit www.kirlinlighting.com and go to your MyKirlin portal. www.kirlinlighting.com

Page 19


MRI LUMINAIRE SYSTEM: Design Guide Ceiling Height Recommended Luminaires

Lower Ceilings (8’-9’)

Higher Ceilings (8’-12’)

Recessed Ambient

Task

Wide Specifiable Distribution Distribution

Patient Table (Aimable)

Surface Accent Wall Wash

Ambient Infection Control *

Wide Distribution

MRR-04200 MRR-06205 MRR-04220

1500

MRR-04225

Lumen Series (20W)

MRR-06230 MRR-06235 MRR-07240 MRS-04245 MRR-06420 MRR-06422 MRR-06424

2500

MRR-06426

Lumen Series (35W)

MRR-06427 MRR-08428 MSR-12440 MRS-08470 * Infection Control Key BioGard™ antimicrobial white finish standard. BioGard™ antimicrobial white finish (Option -BG) optional.

MRI LUMINAIRE / SCONCE SYSTEM: Check List

1. 2. 3. 4. 5.

Select the type and quantity of SmartLED™ Luminaires. See pages 10-13 for available models. Determine the quantity and remote location of the SmartSupply(s). See page 15. Determine the quantity of SmartFilters™. See page 15. Select dimming controls. See page 18. Determine the quantity and remote location (outside MRI shield) of the dimming controls.

See the LPS-1220A (MRI 1400mA SmartSupply™) and RFI-3100D (MRI SmartFilter™) OWNER’S Manuals for installation instructions and wiring diagrams AT www.kirlinlighting.com mykirlin portal.

Page 20

www.kirlinlighting.com


MRI Scenic Panel system: MRP-22290 SERIES • Selection of beautiful smooth panel artwork attractively and uniformly illuminated • Wave guide lens provides superior uniform illumination • Driverless, 20 watt, low voltage, Class II, DC powered. • Regressed trim provides architectural “skylight” effect • Ultra-shallow (2”) recessed aluminum housing

• • • •

IC

Lays into 2’ x 2’ grid ceiling 100-0.2% full range dimming 60,000 hours (L70) life Requires remote SmartSupply™ LPS-0700A and SmartFilter™ RFI-3100D. See page 25 for quantities required

MRP-22290

Regressed bevel provides architectural “skylight” effect.

Use multiple 2’ x 2’ Scenic Panels to create a soothing and attractive luminous ceiling.

23¾” sq [603mm]

Ultra-shallow (2”) aluminum housing requires minimal plenum space.

Use of both Kirlin SmartSupply™ LPS-0700A (700mA) and SmartFilter™ RFI-3100D are required to maintain Kirlin warranty. www.kirlinlighting.com

Page 21


MRI Scenic Panel system: Images Artwork Select artwork by adding the option code (i.e., -A01) of the respective artwork. For custom artwork, use Option -A99.

-A01

-A02

-A03

Custom Artwork (Customer supplied*)

-A05

-A06

-A04

Custom Artwork Preferred Image Resolution 1800 x 1800 pixels (or greater) per 24” x 24” panel. See “Overall Size and Orientation” table on page 23 for preferred image resolution for each configuration.

-A99

* For custom artwork, customer is responsible for supplying the artwork and obtaining the appropriate usage rights.

Dividing and Cropping Artwork When specifying size, orientation and artwork, consider how the image will be divided and cropped. For example:

-4x4

-6x4

-4x6

To see how your artwork will divided and cropped, consult factory. Page 22

www.kirlinlighting.com


MRI Scenic Panel system: Panel Configurations 1. 2. 3. 4. 5.

Use MRP-22290 as base catalog number, then add configurations and selections as follows. Choose overall size and orientation of the display using the “Overall Size and Orientation” table below. Select artwork with option codes (i.e., -A01). Consider how the artwork will be displayed. See “Dividing and Cropping Artwork”. Add appropriate quantity of SmartSupply™ LPS-0700A and SmartFilter™ RFI-3100D (details follow). Following the submission of your order, and before production, you will receive a proof for your review and approval.

Overall Size and Orientation Landscape

Portrait

Option

Preferred Resolution (Pixels)

1

-2x2

1800 x 1800

2’ x 4’

2

-4x2

3600 x 1800

4’ x 4’

4

-4x4

3600 x 3600

4’ x 6’

6

-6x4

5400 x 3600

6’ x 6’

9

-6x6

5400 x 5400

6’ x 8’

12

-8x6

7200 x 5400

8’ x 8’

16

-8x8

7200 x 7200

Nominal Dimensions

Fixture Qty

2’ x 2’

Arrangement

Arrangement

Option

Preferred Resolution (Pixels)

-2x4

1800 x 3600

-4x6

3600 x 5400

-6x8

5400 x 7200

-9x9 Specify number of panels and orientation of artwork.

Custom Size

SCENIC PANEL product SPECIFICATION EXAMPLE MRP-22290 -120 -4x6 -A01

Example: Scenic Panel Product Number

Specify Voltage

Artwork Option

Size and Orientation Option*

*-4x6 is not the same as -6x4, see above. www.kirlinlighting.com

Page 23


MRI SCENIC PANEL: SmartSupply™ DRIVER - REQUIRED • Full range 100% to 0.2% dimming and 3 dimming zones. See page 26 or consult factory for compatible controls. • Over wattage, cross channel, and electrical fast transient (EFT) protection. • Mounted outside MRI shield (not directly to shield). • Input: 115-277VAC / 50-60Hz rated. Dedicated 120VAC input recommended. For 277VAC input, proper line filtering and surge protection must be provided (by others). Maximum continuous input voltage is 290VAC. • Requires 16 AWG (minimum) twisted pair shielded wire from SmartSupply™ to luminaires. • FIVE YEAR Limited Warranty.

LPS-0700A

With Scenic Panels (20W) (12) Channels (Circuits) Maximum Distance Per Channel

(1) scenic panel / channel Up to (12) scenic panels / SmartSupply™ 150 feet

SmartFilter™ DC RFI / EMI FILTER - REQUIRED

• Industry leading RFI and EMI protection • Superior insertion loss of 100 dB (min.) • Fully protects 20 kHz to 1.0 GHz • One filter protects up to three Scenic Panel SmartSupply™ channels • Up to four filters required per Scenic Panel SmartSupply™ • Mounted on outside surface of MRI shield • FIVE YEAR Limited Warranty RFI-3100D 2011 IES Progress Report Selection

MRI SCENIC PANEL SYSTEM ORDERING EXAMPLE Quantity

Page 24

Product

Description

12

MRP-22290-120V-6x4-A03

Scenic Panels

1

LPS-0700A

Scenic Panel SmartSupply™ (700mA) driver (required)

4

RFI-3100D

SmartFilter™ DC RFI/EMI filter (required)

www.kirlinlighting.com


MRI Scenic Panel system: Typical Configuration Scenic Panels (20W)

RFI / EMI Shield Kirlin SmartLED™ Scenic Panels

• Up to (12) 20W scenic panels per SmartSupply • (1) scenic panel per SmartSupply channel (circuit). • Each color represents (1) set of (3) channels Kirlin SmartFilter™ RFI-3100D (Required) • (1) filter protects up to (3) SmartSupply channels. Each color represents (1) set of (3) channels • Up to (4) filters required per SmartSupply • Mounted on outside surface of MRI shield Kirlin SmartSupply™ LPS-0700A (Required) • (12) channels -- (1) scenic panel per channel -- Up to (12) scenic panels per SmartSupply • Max distance per channel -- 50’ with (1) scenic panel per channel • Mounted outside MRI shield (not directly to shield)

MRI Scenic Panel system: Check List 1. Select the quantity and layout of SmartLED™ scenic panels. See page 23. 2. Select the image. Consider how the image will be oriented, cropped and divided. See page 22. 3. Determine the quantity and remote location of the SmartSupply(s). See page 24. 4. Determine the quantity of SmartFilters™. See page 24. 5. Select dimming controls. See page 26. 6. Determine the quantity and remote location (outside MRI shield) of the dimming controls.

See the LPS-0700A (MRI Scenic Panel SmartSupply™) and RFI-3100D (MRI SmartFilter™) OWNER’S Manuals for installation instructions and wiring diagrams at www.kirlinlighting.com mykirlin portal.

www.kirlinlighting.com

Page 25


MRI Scenic Panel system: Typical Wiring Overview This wiring overview provides dimming control for zones 1, 2 and 3 simultaneously with a 0-10V DC dimmer* connected to the master 0-10V DC input of the SmartSupply™.

Shown with: • • • •

Use of both Kirlin SmartSupply (700mA) and SmartFilter are required to maintain Kirlin warranty.

(1) SmartSupply™ LPS-0700A (4) SmartFilters™ RFI-3100D (3) SmartLED™ Scenic Panels (1) Wall Box Dimmer*

Requires 16 AWG (minimum) twisted pair shielded wire from SmartSupply (700mA) to luminaires.

CHANNELS 7-9 CHANNELS 7-9 CHANNELS 10-12

JUNCTION BOX

SmartSupply™ LPS-0700A (Output)

RFI-3100D

SmartFilter™ CHANNELS 10-12

CHANNELS 1-3

CHANNELS 1-3 CHANNELS 4-6

SmartFilter™

SmartFilter™ RFI-3100D

CHANNELS 4-6

SmartFilter™ RFI-3100D

SmartFilter™ RFI-3100D

GREY

CHANNEL 3

SmartSupply™ LPS-0700A (Input)

CHANNEL 2

CHANNEL 1

PURPLE

Scenic Panels

WALL BOX DIMMER*

LINE

AC INPUT

NEUTRAL

Wall dimmer must be mounted OUTSIDE of room shield. Dimming control wires MUST NOT connect through the filter.

* Kirlin recommends using the following compatible 0-10V DC dimmers: Leviton

Lightolier

Acuity

IP710-DLX ZP600FAM-XXX

Sunrise

MP1500FAM-XXX

Momentum

V2000FAMU

Vega

ISD BC

Lutron

NFTV **

Nova

NTSTV-DV **

Nova T

DVTV

Diva

DVSTV **

Diva

V-600

w/GRX-TVI

Vareo

** WARNING! WHEN USING LUTRON NFTV OR NTSTV-DV LOW-VOLTAGE 0-10V DIMMERS, DO NOT SPECIFY OR INSTALL LUTRON PP-SERIES POWER PACKS. USE OF PP-SERIES POWER PACKS MAY CAUSE DAMAGE TO THE SMARTSUPPLY™ THAT IS NOT COVERED UNDER WARRANTY.

Page 26

www.kirlinlighting.com


MRI Scenic Panel system: Wiring Diagram DO NOT CONNECT LED luminaires to energized driver. Use of both Kirlin SmartSupply (700mA) and SmartFilter are required to maintain Kirlin warranty. Requires 16 AWG (minimum) twisted pair shielded wire from SmartSupply (700mA) to luminaires.

BLACK (-)

BLACK (–) CH 3

RED (+) CH 3

BLACK (–) CH 2

RED (+) CH 2

INSIDE MRI ROOM

BLACK (–) CH 1

Wire shields INSIDE room MUST be connected to room shield grounding bar.

RED (+) CH 1

BLACK (–) CH 12

DO NOT CONNECT wire shields to the luminaires.

RED (+) CH 12

BLACK (–) CH 11

RED (+) CH 11

BLACK (–) CH 10

RED (+) CH 10

RED (+)

One Smar tLED™ Scenic Panel Per Circuit

ROOM SHIELD GROUNDING BAR

ROOM SHIELD

BLACK (–) CH 3

GREEN (+) CH 3

BLACK (–) CH 2

DO NOT CONNECT wire shields OUTSIDE room to room shield grounding bar.

RED (+) CH 2

Requires 16 AWG (minimum) twisted pair shielded wire from SmartSupply (700mA) to luminaires.

RFI-3100D

WHITE (+) CH 1

BLACK (–) CH 12

RED (+) CH 12

GREEN (–) CH 11

WHITE (+) CH 11

BLACK (–) CH 10

RFI-3100D

RED (+) CH 10

SmartFilter™

OUTSIDE MRI ROOM

BLACK (–) CH 1

SmartFilter™

Electrical Input: 115-277VAC / 50-60Hz isolated circuit only. Maximum input voltage 290V.

SmartFilter™ RFI-3100D

ZONE 4

ZONE 1

ZONE 3

ZONE 2

SmartSupply™ LPS-0700A*

To SmartFilter™

RFI-3100D SmartFilter

* DO NOT MOUNT OR CONNECT SmartSupply (700mA) to room shield.

For more information on Kirlin’s SmartLED™ MRI lighting systems, including specification sheets and owner’s manuals (including installation instructions and wiring diagrams), please visit www.kirlinlighting.com and go to your MyKirlin portal. www.kirlinlighting.com

Page 27


SECTION II: exam lighting

(recessed Downlight / Adjustable)

Three Levels of Infection Control Protection HIGHER QUALITY LIGHT • Select delivered lumens from 1500-5000 in downlight or adjustable designs. • Choose the color of your light: 2700K (very warm white), 3000K (warm white), 3500K (neutral white, standard), 4100K (cool white) or 5000K (daylight white). • High CRI available (Option -HC) for accurate tissue color rendering: CRI 90+ with high R9 (Red), R13 and R15 (Skin Colors).

A SAFER ENVIRONMENT • Fully recessed fixtures provide an open work space. • Compact and smooth trim and lens are easy to clean and disinfect. • BioGard™ antimicrobial finish inhibits the growth of pathogens. • IP65 sealed trims minimize the likelihood of pathogens passing through the fixture. • ISO 5 Class 100 sealed fixtures for “cleanroom” applications. • Impact resistant lenses available (ideal for emergency departments and psychiatric units).

GREATER PERFORMANCE • Dimming down to 10% permits staff to finely tune light levels for specific tasks, each clinician and time of day. • Higher delivered lumens and 50% energy savings over fluorescent troffers. • Multi-light system removes debilitating shadows.

Level 1 Protection

oG

Bi

Lensed, BioGard™ antimicrobial finish

oG

IP65 sealed trim, BioGard™ antimicrobial finish

Bi

oG

Bi

IP65 sealed trim, vandal resistant, BioGard™ antimicrobial finish

Level 3 Protection

oG

Bi

ISO 5/class 100 sealed “cleanroom” fixture, BioGard™ antimicrobial finish

Level 3 + Protection

ISO 5/class 100 sealed fixture, vandal resistant, BioGard™ antimicrobial finish

Page 28

IP65

d™ ar

oG

Bi

d™ ar

IP65

ISO 5

100

CLEANROOM

IP65

VR

IP65

d™ ar

CLASS

Level 2 + Protection

d™ ar

ISO 5 CLASS

Level 2 Protection

d™ ar

100

CLEANROOM

VR

www.kirlinlighting.com


SECTION II: exam lighting

(recessed Downlight / Adjustable)

Infection Control

Application

Function

Aperture (Inches)

Level 1 Protection

Antimicrobial BioGard™ Finish Regressed Lens

Downlight

7

Level 1 Protection

Antimicrobial BioGard™ Finish Regressed Lens

Adjustable

Level 1 Protection

Antimicrobial BioGard™ Finish Regressed Lens

Downlight

4x9

Level 1 Protection

Antimicrobial BioGard™ Finish Regressed Lens

Downlight

5 x 11

Level 2 Protection

IP65 Rated BioGard™ Finish Regressed Lens

Downlight

Level 2 Protection

IP65 Rated BioGard™ Finish Regressed Lens

Adjustable

Level 2+ Protection

IP65 Rated - BioGard™ Tamper Resistant Psychiatric/ED

Downlight

Level 2+ Protection

IP65 Rated - BioGard™ Tamper Resistant Psychiatric/ED

Adjustable

Level 3 Protection

Class 100 Cleanroom BioGard™ Finish OR/Hybrid OR

Downlight

7

Level 3 Protection

Class 100 Cleanroom BioGard™ Finish OR/Hybrid OR

Downlight

8

Level 3 Protection

Class 100 Cleanroom BioGard™ Finish OR/Hybrid OR

Adjustable

Level 3+ Protection

Class 100 Cleanroom Tamper Resistant BioGard™ Finish Psychiatric/OR

Downlight

Level 3+ Protection

Class 100 Cleanroom Tamper Resistant BioGard™ Finish Psychiatric/OR

Product #

Performance Lumens

Watts

MRR-07500-5000L

5000

55

MRR-07500-3500L

3500

42

MRR-07505-5000L

5000

55

MRR-07505-3500L

3500

42

MRT-04510-5000L

5000

70

MRT-05515-7000L

7000

84

MRT-05515-5000L

5000

70

MRR-08530-5000L

5000

55

MRR-08530-3500L

3500

42

MRR-08535-5000L

5000

55

MRR-08535-3500L

3500

42

MRV-08540-5000L

5000

55

MRV-08540-3500L

3500

42

MRV-08545-5000L

5000

55

MRV-08545-3500L

3500

42

MRR-07550-1500L

1500

15

MRR-08555-5000L

5000

55

MRR-08555-3500L

3500

42

MRR-08558-5000L

5000

55

MRR-08558-3500L

3500

42

MRV-07560-1500L

1500

15

MRV-08565-5000L

5000

55

MRV-08565-3500L

3500

42

Page

7 30

8 31

8

8 31

8

32

8

7

32

Downlight

8

INSTALLATIONS, options and ordering

33-35

PLEASE VISIT www.kirlinlighting.com FOR KIRLIN TUNGSTEN HALOGEN EXAM LIGHTING PRODUCTS IN KIRLIN’S PATIENT EXAM & HEALTHCARE LIGHTING CATALOG (BULLETIN 08HC). www.kirlinlighting.com

Page 29


SECTION II: exam lighting

Level 1 Protection

Lensed, BioGard™ antimicrobial finish

oG

Bi

d™ ar

7” MAXIMUM PERFORMANCE (-5000L Series)

Downlight

Cone of Light ▲

4827 LUMENS 55W

Dist. 6 8 10 12 14 16

FC 247.0 139.0 89.1 61.9 45.5 34.8

439 405

305

195

Dia. 3.5 4.7 5.9 7.1 8.3 9.4

fc on Task: 8’ Ceiling 3’6” Work Plane

MRR-07500-5000L MRR-07500-3500L

Narrow Flood (Standard) Shown. Medium Flood (-MFL) Optional

7”

Adjustable

Patient Room Cardiac Cath Labor and Delivery Radiology PreOp / PostOp Veterinary Autopsy

MAXIMUM PERFORMANCE (-5000L Series) 740 614

375

Applications:

210

4623 LUMENS 55W

fc on Task: 8’ Ceiling 3’6” Work Plane

MRR-07505-5000L MRR-07505-3500L

Narrow Flood (Standard) Shown

4” x 9”

▲ Cone of Light Key

PERFORMANCE (-5000L Series) Cone of Light ▲

5249 LUMENS 2 x 35W

Dist. 6 8 10 12 14 16

FC 709.0 399.0 255.0 177.0 130.0 99.7

1245 984

515

Ft. Distance from fixture FC Footcandles at nadir (0°) Dia. Circle of light at 50% of FC

213

Dia. (in ft.) shown is where FC value is half the FC at nadir.

Dia. 2.2 2.9 3.6 4.3 5.1 5.8

Downlights

fc on Task: 8’ Ceiling 3’6” Work Plane

Applications:

MRT-04510-5000L

Narrow Flood (Standard) Shown

5” x 11”

Patient Room ICU / NICU Labor and Delivery PreOp / PostOp Veterinary Autopsy

MAXIMUM PERFORMANCE (-7000L Series) Cone of Light ▲

7089 Lumens 2 x 42W

Dist. 6 8 10 12 14 16

FC 1200.0 676.0 433.0 300.0 221.0 169.0

2129 1610 684

239

Dia. 1.9 2.5 3.2 3.8 4.4 5.1

fc on Task: 8’ Ceiling 3’6” Work Plane

MRT-05515-7000L MRT-05515-5000L

Page 30

Narrow Flood (Standard) Shown

www.kirlinlighting.com


SECTION II: exam lighting 8”

Level 2 Protection

Downlight

5298 Lumens 55W

Dist. 6 8 10 12 14 16

FC 298.0 168.0 107.0 74.6 54.8 42.0

530

484

357

IP65

220

Dia. 3.4 4.5 5.7 6.8 7.9 9.1

fc on Task: 8’ Ceiling 3’6” Work Plane

Narrow Flood (Standard) Shown. Medium Flood (-MFL) Optional

8”

513

Applications: ICU / NICU PreOp / PostOp Autopsy Veterinary PT / CT Scan Infection Control Areas

MAXIMUM PERFORMANCE (-5000L Series) 1143 969

Adjustable

d™ ar

MAXIMUM PERFORMANCE (-5000L Series) Cone of Light ▲

MRR-08530-5000L MRR-08530-3500L

oG

Bi

IP65 sealed trim, BioGard™ antimicrobial

220

4796 Lumens 55W

fc on Task: 8’ Ceiling 3’6” Work Plane

MRR-08535-5000L MRR-08535-3500L

Narrow Flood (Standard) Shown

Level 2 + Protection

oG

Bi

IP65 sealed trim, vandal resistant, BioGard™ antimicrobial finish

8”

4749 Lumens 55W

Dist. 6 8 10 12 14 16

FC 243.0 137.0 87.6 60.8 44.7 34.2

432

396

295

Dia. 3.5 4.7 5.8 7.0 8.1 9.3

Applications:

Narrow Flood (Standard) Shown. Medium Flood (-MFL) Optional

8”

Emergency Psychiatric Prison / Jail PreOp / PostOp Veterinary Patient Room

MAXIMUM PERFORMANCE (-5000L Series) 1169 963

Adjustable

VR

187

fc on Task: 8’ Ceiling 3’6” Work Plane

MRV-08540-5000L MRV-08540-3500L

IP65

MAXIMUM PERFORMANCE (-5000L Series) Cone of Light ▲

Downlight

d™ ar

441

162

4185 Lumens 55W

fc on Task: 8’ Ceiling 3’6” Work Plane

MRV-08545-5000L MRV-08545-3500L

Narrow Flood (Standard) Shown

▲ Cone of Light Key

Ft. Distance from fixture FC Footcandles at nadir (0°) Dia. Circle of light at 50% of FC Dia. (in ft.) shown is where FC value is half the FC at nadir.

www.kirlinlighting.com

Page 31


Level 3 Protection

ISO 5/class 100 sealed fixture

Cone of Light ▲

1553 Lumens

IC

Dist. 6 8 10 12 14 16

FC 89.3 50.2 32.1 22.3 16.4 12.6

158 145

110

CLEANROOM

Dia. 3.5 4.7 5.9 7.1 8.2 9.4

fc on Task: 8’ Ceiling 3’6” Work Plane

Narrow Flood (Standard) Shown. Medium Flood (-MFL) Optional

MAXIMUM PERFORMANCE (-5000L Series)

8”

Cone of Light ▲

5298 Lumens 55W

Dist. 6 8 10 12 14 16

FC 298.0 168.0 107.0 74.6 54.8 42.0

530

484

Applications:

357

220

Operating Room Hybrid OR Intraoperative OR CCU Cleanroom Cardiac Cath Interventional Radiology

Dia. 3.4 4.5 5.7 6.8 7.9 9.1

fc on Task: 8’ Ceiling 3’6” Work Plane 2013 IES Progress Report Selection

Narrow Flood (Standard) Shown. Medium Flood (-MFL) Optional

MAXIMUM PERFORMANCE (-5000L Series)

8” Adjustable

1143 969

513

220

4796 Lumens 55W

MRR-08558-5000L MRR-08558-3500L

fc on Task: 8’ Ceiling 3’6” Work Plane

Narrow Flood (Standard) Shown

Level 3 + Protection

oG

Bi

ISO 5/class 100 sealed fixture, vandal resistant, BioGard™ antimicrobial finish

Cone of Light ▲

1468 Lumens 20W

MRV-07560-1500L

IC

Dist. 6 8 10 12 14 16

FC 70.8 39.8 25.5 17.7 13.0 10.0

125 117

92

ISO 5

100

CLEANROOM

VR ▲ Cone of Light Key

61

Ft. Distance from fixture FC Footcandles at nadir (0°) Dia. Circle of light at 50% of FC

Dia. 3.8 5.0 6.3 7.5 8.8 10.0

Dia. (in ft.) shown is where FC value is half the FC at nadir.

MAXIMUM PERFORMANCE (-5000L Series)

4749 Lumens 55W

Dist. 6 8 10 12 14 16

FC 243.0 137.0 87.6 60.8 44.7 34.2

432

396

295

Applications: Emergency Psychiatric Prison / Jail PreOp / PostOp Veterinary Patient Room

Narrow Flood (Standard) Shown. Medium Flood (-MFL) Optional

Cone of Light ▲

Page 32

IP65

fc on Task: 8’ Ceiling 3’6” Work Plane

8”

MRV-08565-5000L MRV-08565-3500L

d™ ar

PERFORMANCE (-1500L Series)

7”

Downlights

ISO 5

100

70

CLASS

Downlights

20W

MRR-08555-5000L MRR-08555-3500L

IP65

d™ ar

PERFORMANCE (-1500L Series)

7”

MRR-07550-1500L

oG

Bi

CLASS

SECTION II: exam lighting

187

Dia. 3.5 4.7 5.8 7.0 8.1 9.3

fc on Task: 8’ Ceiling 3’6” Work Plane

Narrow Flood (Standard) Shown. Medium Flood (-MFL) Optional

www.kirlinlighting.com


KIRLIN LED exam lighting Outperforms antiquated troffers Performance

Reliability

• Over 50% energy savings • Higher delivered lumens • Fewer luminaires, lower cost • Exceeds IES recommended light levels • Better illumination uniformity; no glare • Instant on, reliable dimming

Infection Control

• BioGard™ antimicrobial finish • Smaller lens and trim for faster cleaning • Award winning cleanroom 2013 IES Progress versions offered

Installation and Maintenance

Report Selection

• IEC/EN 60601-1-2 medical listing • FCC Part 15 EMI/RFI emissions • Internal emergency battery packs available. Deliver 500 or 1000 lumens. Run time 90+ minutes. See options -EM and -EMH. • SmartSupply™ remote driver (LPS-1220A) available. Full range 100% to 0.2% dimming and 3 dimming zones. Drives up to (12) -1500L luminaires or (3) -5000L Level 3 luminaires. See Option -SS and page 35. • SmartPower™ emergency inverter (EMI-21220) available. Provides 100% lumen output for up to two hours. See page 35.

• Maintenance-free LEDs • Smaller size for easier installation • Shallow depth housings fit anywhere Zone

Lighting Performance

Location

fc

1

OR Table

800

2

Near OR Table

200

3

OR Perimeter

100

Luminaires*

Fixture Qty

MRR-08558-5000L

6

MRR-08555-5000L

15

* See www.kirlinlighting.com for specification sheets.

Operating Room Zones

5' - 6"

30' - 0”

2' - 7"

734 880 734

Zone 2 200 fc

6' - 0"

734 880 734

6' - 6"

633 821 633

Zone 1 800 fc

6' - 0"

Footcandles on Operating Table

531 710 531

2' - 7"

Zone 3 100 fc

633 821 633

24' - 0” 531 710 531

Zone 2 200 fc

www.kirlinlighting.com

Page 33


SECTION II: exam lighting Two Adjustable Exam Lights

Two Adjustable Exam Lights in NICU

Placed 4’ apart on centers over the head and foot of the bed.

4’ [112cm]

LUMINAIRE

Typical Installations Placed over the foot corners of the bed.

23° (35° Max)

22° (35° Max) SITE

8’ [244cm]

4’ [112cm]

LUMINAIRES

2’ 8‘’ [81cm] 30°

SITE 8’ [244cm] 3’ 4” [101cm]

3’ [91cm]

Front View

One Adjustable Exam Light

Side View

One Fixed Exam Light

Placed over the head (or foot) of the bed to avoid obstructions in ceiling.

Placed over center of the bed.

LUMINAIRE

LUMINAIRE

22° (35° Max) SITE

8’ [244cm]

3’ [91cm]

3’ [91cm]

SECTION II: exam lighting Input Power: SPECIFY -120 120V (50-60Hz) input and thermal protector. -277 277V (50-60Hz) input and thermal protector. -97 Specify other voltage. Consult factory.

LED Power Supply -29 Two wire full range (100-1%) PWM dimming instead (Lutron). 120V only. Not available with Option -EI. -39 Three wire full range (100-1%) PWM dimming instead (Lutron). -EI REMOTE emergency inverter for 45% of rated lumens for -5000L, 55% for -3500L or 100% for -1500L. Run time: 90+ minutes. 120 or 277V, 60 Hz input only. Specify voltage. Not for use with -SS SmartSupply™ driver or with Option -29. -EM INTERNAL emergency battery pack. Delivers 500 lumens. Run time: 90+ minutes.

SITE

8’ [244cm]

POPULAR Options

-EMH INTERNAL emergency battery pack. Delivers 1000 lumens. Run time: 90+ minutes. Marked spacings installation may be required; refer to specification sheet. -ER REMOTE emergency battery pack. Delivers 500 lumens. Run time: 90+ minutes. -ERH REMOTE emergency battery pack. Delivers 1000 lumens. Run time: 90+ minutes. -SS Remote mounted Kirlin SmartSupply™ driver (instead of standard internal driver), sold separately. Order LPS-1220A (0-10V analog with 100-0.2% PWM dimming). Available for -1500L and -5000L lumen series luminaires only. Refer to page 35 and LPS-1220A specification sheet and owner’s manual at www.kirlinlighting.com.

Color Temperature (CCT) -27K Color temperature 2700°K instead. 85 CRI. -30K Color temperature 3000°K instead. 85 CRI.

(See specification sheets for availability and details.) Page 34

-41K Color temperature 4100°K instead. 85 CRI. -50K Color temperature 5000°K instead. 85 CRI. -HC 90+ CRI instead. 2700° or 3000°K only. Reduces output by ~15%.

Optics (-NFL Standard) -MFL Medium flood distribution instead.

Trims -32 -45 -46

White oversize trim ring. Specify O.D. Gasket between trim flange and ceiling. Gasket between trim and lens.

Other -99 -FD -FS

Special modification. Consult factory. Dual circuit fusing. For use only with Option -EI and either -5000L or -3500L lumen series. In-line fusing. Not for use with Option -EI and either -5000L or -3500L lumen series: See -FD instead.

www.kirlinlighting.com


SmartSupply™ REMOTE DIMMING DRIVER - OPTIONAL • Full range 100% to 0.2% dimming and 3 dimming zones. • Drives up to (12) -1500L, or up to (3) -5000L luminaires. • Over wattage, cross channel, and electrical fast transient (EFT) protection. • Input: 115-277VAC / 50-60Hz rated. Dedicated 120VAC input recommended. For 277VAC input, proper line filtering and surge protection must be provided. Maximum continuous input voltage is 290VAC. • Requires 16 AWG (minimum) twisted pair shielded wire from SmartSupply™ to luminaires. • FIVE YEAR Limited Warranty.

LPS-1220A

See LPS-1220A Owner’s Manual for more information, including compatible controls and wiring diagrams, at www.kirlinlighting.com MyKirlin Portal.

SmartPower™ EMERGENCY BACKUP SYSTEM - OPTIONAL

• High efficiency pure sine wave inverter • Operates up to (6) -5000L series fixtures • 100% light output for up to two hours • 120 / 277V, 60Hz input • Less than 50 milliseconds transfer time

• May be mounted up to 1000 feet from load • UL 924 Listed. Meets or exceeds all NEC and Life Safety Code Emergency Lighting Requirements • THREE YEAR Limited Warranty

EMI-21220

Luminaire Ordering EXAMPLE MUST SPECIFY

OPTIONAL

Product Number

Voltage

Options

MRV-08565-5000L MRV-08565-3500L

-120 (120 volts) -277 (277 volts) -97 (Specify other)

See “Options” on prior page

Ordering Example: MRV-08565-5000L-120-30K-MFL

LUMEN SERIES AVAILABLE Lumen Series Code

Nominal Lumens

-5000L

5000 Lumens

-3500L

3500 Lumens

-1500L

1500 Lumens

www.kirlinlighting.com

Page 35


SECTION III: motorized exam lighting & Controls HIGHER QUALITY LIGHT with OPTeCOLOR™ • Choose the color of your light: 3500K (Neutral white: Standard), 4100K (Cool white: Option -41K) or 5000K (Daylight white: Option -50K) • Ultra-high 95+ CRI with high R9 (Red), R13 and R15 (Skin Colors) for accurate tissue color rendering. • High illuminance for deep cavities or challenging positions. Up to 9000 delivered footcandles from 5 feet, dimmable to 10%.

High CRI

Common CRI

GREATER CONTROL • Independent control of each lighthead permits adjustable pattern of light and dual task illumination. • Intuitive and responsive controls allow for quick and accurate adjustment of direction and intensity of the light. • Angles of illumination up to 60° ensure the task is properly illuminated regardless of the task location or clinicians’ position. • Dimming down to 10% permits staff to finely tune levels, as needed.

A SAFER ENVIRONMENT • Recessed fixtures provide an open work space. The light remains recessed, protecting the patient from contaminants near or above the ceiling. • IP65 trims with BioGard™ antimicrobial finish protect against pathogens.

IP65

G io

d™ ar

B

IES Progress Report Selections

GREATER COMFORT • Cool LED illumination does not project heat toward the room, assuring patient and practitioner comfort and avoiding tissue desiccation. • Inconspicuous: Fully recessed fixtures provide a more residential atmosphere; Remote control does not need to be used near the patient. • Remote control technology employs invisible infrared signal, preventing the triggering of photosensitive conditions (migraines, epileptic seizures, stress).

DEPENDABILITY • Redundancy of LED circuits ensures illumination at all times. Redundancy of controls (wall or remote) ensures 24/7 adjustability of illumination intensity and position. • Impact resistant design protects remote control. • Loss deterring beeper feature on the remote control reminds staff to return the remote to its “home plate” on the wall control panel.

Exclusive Three Year Warranty • Designed and Produced in U.S.A. • UL, C-UL (Canada) Listed Page 36

www.kirlinlighting.com


SECTION III: motorized exam lighting & Controls

INFRALED® 60 • INFRALED® • OPTeMED™ Name

Application

Design

Delivered Lumens

Total Watts

Aperture (Inches)

Product #

Remote Control and Wall Control with recessed motorized luminaire(s)

38-41

INFRALED® 60

LDRP/OB

Pair

8000

280

17

MRS-17600

INFRALED

Intraoperative OR Hybrid OR ICU/CCU Cardiac Cath

Pair

6000

140

12

MRR-12620

®

Page

38-39

40-41

INFRALED®

ED Patient Room

Single

3000

70

12

MRR-12622

Wall Control with recessed motorized luminaire(s)

OPTeMED™

PICU/NICU ED Trauma

42-43

Pair

6000

140

12

MRR-12640

42-43

OPTeMED™

PICU/NICU Patient Room Autopsy

Single

3000

70

12

MRR-12642

PLEASE VISIT www.kirlinlighting.com FOR KIRLIN TUNGSTEN HALOGEN MOTORIZED EXAM LIGHTING IN KIRLIN’S PATIENT EXAM & HEALTHCARE LIGHTING CATALOG (BULLETIN 08HC).

www.kirlinlighting.com

Page 37


SECTION III: motorized exam lighting THE BIRTHING LIGHTING SYSTEM / SOLUTION LED Remote Controlled Motorized 60° High Angle Recessed Patient Low Voltage Lighting System MRS-17600 (Two Light System) 2015 IES Progress Report Selection

FEATURES • Light delivered at angles up to 60° to match the clinician’s line of site for superior illumination of the birthing canal. • Four OPTeCOLOR™ LED light heads per system deliver up to 6000 fc with no heat in the beam. • OPTeCOLOR™ LEDs provide 95+ CRI (with high R9, R13 and R15) for excellent color rendering of blood, tissue and skin tones. 60,000 hour life (L70) dramatically reduces maintenance frequency and cost. • Redundancy of controls, electronic components and circuitry ensures control of fixtures and at least 75% illumination at all times. • Fully recessed fixtures with BioGard™ antimicrobial trims are unobtrusive and inconspicuous, providing a safe and open space for staff and a home-like atmosphere for patients. • Full control of lighting system (direction, intensity, power) from low voltage, Class 2 remote and wall controls. • Remote control uses invisible and safe infrared signals. Impact resistant design protects remote from common mishaps. Loss deterring beeper reminds staff to return the remote to the wall control when finished. • Smooth surfaces and minimal surface areas (both fixtures and controls) are easy to clean and disinfect. • Kirlin’s exclusive three year limited warranty (one year remote control). • Includes 2’ x 2’ ceiling pan for easy installation in T-bar ceiling or see Option -47. oG

Bi

d™ ar

Applications • Birthing Suites

• Post-partum

• Labor & Delivery

• OB/GYN/LDRP 22” SQ (559mm)

11-1/4” (286mm)

60° 18-3/8” (467mm)

LEFT LIGHT LOW BATTERY INDICATOR

INFRALED ® 60

FOOT

RIGHT LIGHT

LED RECESSED ADJUSTABLE MEDICAL LIGHTING SYSTEM

HEAD

ADJUST POSITION

BRIGHT

SELECT LIGHT

ON OFF DIM

5” (127mm)

DIRECTIONS FOR USE

HEAD

1 Turn system ON

STORE REMOTE CONTROL HERE

2 SELECT LIGHT to be adjusted

ADJUST POSITION

3 ADJUST POSITION 4 Repeat steps 2 - 3 for additional light

Beeper is activated in 60 minute intervals unless remote is used or returned to wall control storage area

SELECT LIGHT

FOOT

BRIGHT

6 Turn system OFF and store remote control

INFRARED REMOTE CONTROL FOR

INFRALED ® 60

5 Adjust BRIGHT / DIM

5-5/8” (143mm)

4-1/2” (114mm)

ON OFF DIM

www.kirlinlighting.com

Detroit, MI • www.kirlinlighting.com

2-3/4” (70mm)

8-1/8” (206mm)

2-1/2” (64mm)

Popular Options Input Power: SPECIFY

Color Temperature (CCT)

-120 120V (50-60Hz) input and thermal protector. -58 277/120 volt stepdown transformer for 277 volt line input, prewired into each fixture; with 277 volt thermal protector. -97 For other input supply voltages, consult factory. -98 347/120 volt stepdown transformer for 347 volt line input, prewired into each fixture; with 120 volt thermal protector. Adds 10 watts to each fixture load.

-41K 4100°K instead of 3500°K. 95+ CRI. -50K 5000°K instead of 3500°K. 95+ CRI.

Page 38

Trim and Other -47 -87 -94

Plaster frame bottom pan. For installation in hard ceilings. Custom length (> 35 feet) plenum rated wall control cables (4). Consult factory. Custom color self-flanged flare trim instead. Consult factory.

-99 -BI -RC -RS -SE

Special modification. Consult factory. Beeper (remote control) inactivated by factory. Extra remote control. Remote infrared sensor with 35’ cable. Ceiling mount typical. Fixtures modified for seismic anchorage (by others). Meets California OSHPD and International Building Codes.

(See specification sheets for availability and details.) www.kirlinlighting.com


SECTION III: motorized exam lighting THE BIRTHING LIGHTING SYSTEM / SOLUTION Recommendations for Typical Installation •

Fixtures placed 4’ apart (on centers) to project light on either side of practitioner’s head and over practitioner’s shoulders.

Fixture setback from break in bed determined by ceiling height, and position and height of practitioners.

Ideal angle of illumination should be between 50°55° for sitting practitioners which provides future flexibility should task location change. Consult factory for assistance in determining ideal location of fixtures.

Typical Side View: 8’ Ceiling Height LUMINAIRE (ONE SHOWN)

LOW VOLTAGE CABLE 35’ [1067cm] WALL CONTROL & BACK BOX SITE

ANGLE of ILLUMINATION

8’ [244cm] CEILING HEIGHT

TASK HEIGHT 3’ [91cm]

3.5’ [107cm]

6’ 7” [201cm]

Wall control placed in unobstructed location and within line of sight from practitioner's location.

SETBACK

Typical Top View: 8’ Ceiling Height Recommended Fixture Setback / Location with Angle of Illumination and Light Levels

SITE

SPACING

(ON CENTER)

Sitting Practitioners

Ceiling Height

Setback from Break in Bed

Photometric testing by ITL (Boulder, CO) ITL Test No. 84926

Angle of Illumination

Footcandles on Task

7.0

Optimal

54.5

5105

6.0

Alternative

50.2

6052

8.0

Optimal

55.5

4080

7.0

Alternative

51.8

4851

8.0

Optimal

53.1

3850

4’ [122cm]

SETBACK 6’ 7” [201cm]

8

Sitting Practitioners 4' Spacing • 3' Work Plane • 53° Angle of Illumination

8.5

9

SITE

SPACING

7.0

Alternative

49.4

4515

9.0

Optimal

54.2

3163

8.0

Alternative

50.9

3622

9.0

Optimal

52.1

2997

9.5

10

Typical Top View: 9' Ceiling Height

Alternative setback provided for room configurations that do not allow fixture placement in optimal setback location. For additional setback locations, consult factory.

www.kirlinlighting.com

(ON CENTER)

4’ [122cm]

SETBACK 6’ 7” [201cm]

Sitting Practitioners 4' Spacing • 3' Work Plane • 53° Angle of Illumination

Page 39


SECTION III: motorized exam lighting LED Remote Controlled Motorized Recessed Patient Low Voltage Lighting System MRR-12620 (Two Light System) MRR-12622 (One Light System) FEATURES • OPTeCOLOR™ LEDs deliver up to 10,000 fc with no heat in the beam. • OPTeCOLOR™ LEDs provide 95+ CRI (with high R9, R13 and R15) for excellent color rendering of blood, tissues and skin tones. 60,000 hour life (L70) dramatically reduces maintenance frequency and cost. • Light delivered at angles up to 35° (50° with Option -81) with full 360° rotation to provide coverage of the patient. • Redundancy of controls, electronic components and circuitry ensures control of lights and at least 75% (MRR12620) illumination at all times. • Fully recessed fixtures with BioGard™ antimicrobial trims are unobtrusive and inconspicuous, providing a safe and open space for staff and a home-like atmosphere for patients. • Full control of lighting system (direction, intensity, power) from low voltage , Class 2 remote and wall controls. Independent direction control of each light. Light beams may be aimed at 2 separate sites or superimposed. • Remote control uses invisible and safe infrared signals. Impact resistant design protects remote from common mishaps. Loss deterring beeper reminds staff to return the remote to the wall control when finished. • Smooth surfaces and minimal surface areas (both fixtures and controls) are easy to clean and disinfect. • Kirlin’s exclusive three year limited warranty (one year remote control). • Easily installs in T-bar or drywall ceiling with mounting hardware provided.

Applications • ICU/CCU

• ED

• NICU/PICU

• CATH LAB 22” SQ (559mm)

12” (305mm)

35° 11-3/8” (289mm)

LEFT LIGHT LOW BATTERY INDICATOR

FOOT

BRIGHT

SELECT LIGHT

ON OFF DIM

5” (127mm)

RIGHT LIGHT

DIRECTIONS FOR USE

HEAD

1 Turn system ON

STORE REMOTE CONTROL HERE

2 SELECT LIGHT to be adjusted

ADJUST POSITION

Beeper is activated in 60 minute intervals unless remote is used or returned to wall control storage area

3 ADJUST POSITION 4 Repeat steps 2 - 3 for additional light

SELECT LIGHT

FOOT

BRIGHT

INFRALED ®

5 Adjust BRIGHT / DIM 6 Turn system OFF and store remote control

INFRARED REMOTE CONTROL FOR

5-5/8” (143mm)

4-1/2” (114mm)

ON OFF DIM

www.kirlinlighting.com

Detroit, MI • www.kirlinlighting.com

2-3/4” (70mm)

Popular Options

2-1/2” (64mm)

8-1/8” (206mm)

-94

Input Power: SPECIFY

Color Temperature (CCT)

-120 120V (50-60Hz) input and thermal protector. -58 277/120V stepdown transformer for 277V line input, prewired into each fixture; with 277V thermal protector. -97 For other input supply voltages, consult factory. -98 347/120V stepdown transformer for 347V line input, prewired into each fixture; with 120V thermal protector. Adds 10 watts to each fixture load.

-41K 4100°K instead of 3500°K. 95+ CRI. -50K 5000°K instead of 3500°K. 95+ CRI.

Page 40

INFRALED ® LED RECESSED ADJUSTABLE MEDICAL LIGHTING SYSTEM

HEAD

ADJUST POSITION

Trim and Other -32 -81 -87

White oversize trim ring. Specify O.D. 15° bottom pan achieves 50° high angle illumination in one direction. Maximum recessed depth 15-1/8”. Custom length (> 35 feet) plenum rated wall control cables (4 for MRR-12620; 2 for MRR-12622). Specify length.

Custom color self-flanged flare trim instead. Consult factory. -99 Special modification. Consult factory. -BI Beeper (remote control) inactivated by factory. -IP IP65 rated trim and lens. -RC Extra remote control. -RS Remote infrared sensor with 35’ cable. Ceiling mount typical. -SE Fixtures modified for seismic anchorage (by others). Meets California OSHPD and International Building Codes.

(See specification sheets for availability and details.) www.kirlinlighting.com


SECTION III: motorized exam lighting Typical Side View: MRR-12620 in NICU

Typical Side View: MRR-12620 in Patient Room 4’ [112cm]

LUMINAIRES

4’ [112cm]

CONTROL CABLE 35’ [1067cm] 23° (35° Max)

WALL CONTROL & BACK BOX

22° (35° Max)

2’ 8‘’ [81cm]

30°

SITE

8’ [244cm]

8’ [244cm] 3’ 6” [107cm]

3’ [91cm]

3’ 6” [107cm]

3’ 4” [101cm] Front View

Side View

Typical Side View: MRR-12622 in Patient Room LUMINAIRE

CONTROL CABLES 35’ [1067cm]

oG

Bi

d™ ar

OPTeCOLOR™ LEDs

WALL CONTROL & BACK BOX

Optional 15° bottom pan (Option -81) allows lighthead to be tilted up to 50° for high angle illumination or to accommodate fixture location further from the bed.

SITE

8’ [244cm]

3.5’ [107cm]

3’ [91cm]

Footcandle Distribution Data: MRR-12620 (Two Light System) 4' Spacing 8990 2150 160

8' Ceiling:

6670 2460 200

60

3' Work Plane 8990 fc 3'4" Work Plane 10000 fc

9' Ceiling:

5110 2550 240

60

3' Work Plane 3'4" Work Plane

Photometric testing by ITL (Boulder, CO) I.T.L. Test No. 83197

6670 fc 7330 fc

10' Ceiling:

60

3' Work Plane 3'4" Work Plane

5110 fc 5570 fc

Footcandle Distribution Data: MRR-12622 (One Light System) 5610

8' Ceiling:

920

70

3' Work Plane 3'4" Work Plane

www.kirlinlighting.com

3900 1150

30

5610 fc 6420 fc

9' Ceiling:

90

2870 1250 110

30

3' Work Plane 3'4" Work Plane

3900 fc 4370 fc

10' Ceiling:

30

3' Work Plane 3'4" Work Plane

2870 fc 3160 fc Page 41


SECTION III: motorized exam lighting LED Motorized High CRI / R9 Recessed Patient Low Voltage Lighting System

OPTe MED™

2014 IES Progress Report Selection

MRR-12640 (Two Light System) MRR-12642 (One Light System) FEATURES • OPTeCOLOR™ LEDs deliver up to 10,000 fc with no heat in the beam. • OPTeCOLOR™ LEDs provide 95+ CRI (with high R9, R13 and R15) for excellent color rendering of blood, red tissues and skin tones. 60,000 hour life (L70) dramatically reduces maintenance frequency and cost. • Light delivered at angles up to 35° (and 50° with Option -81) with full 360° rotation to provide coverage of the patient. • One hand operation of wall control: joystick (360°) for direction; slide dimmer for intensity (100-10%); push button for power on-off. • Independent direction control of each light. Light beams may be aimed at 2 separate sites or superimposed. • Fully recessed fixtures with BioGard™ antimicrobial trims are unobtrusive and inconspicuous, providing a safe and open space for staff and a home-like atmosphere for patients. Easily installs in T-bar or drywall ceilings with mounting hardware provided. • Smooth surfaces and minimal surface areas (both fixtures and controls) are easy to clean and disinfect. • Redundancy of electronic components and circuitry ensures at least 75% (MRR-12640) illumination at all times. • Kirlin’s exclusive three year limited warranty.

MRR-12640

MRR-12642

Applications • ICU/CCU

• ED

• NICU/PICU

• PATIENT ROOM 16-7/8” x 13” (429mm x 330mm)

11-5/8” (295mm)

35° 11-3/8” (289mm) OPTe MED™

OPTe MED™

DIMMER

DIMMER

HEAD

LEFT

HEAD

RIGHT

LEFT

FOOT

RIGHT

FOOT

5-9/16” (141mm)

8-1/8” (206mm)

Input Power: SPECIFY

Color Temperature (CCT)

-120 120V (50-60Hz) input and thermal protector. -58 277/120 volt stepdown transformer for 277 volt line input, prewired into each fixture; with 277 volt thermal protector. -97 For other input supply voltages, consult factory. -98 347/120 volt stepdown transformer for 347 volt line input, prewired into each fixture; with 120 volt thermal protector. Adds 10 watts to each fixture load.

-41K 4100°K instead of 3500°K. 95+ CRI. -50K 5000°K instead of 3500°K. 95+ CRI.

Page 42

Trim and Other -32 -81 -87

White oversize trim ring. Specify O.D. 15° bottom pan achieves 50° high angle illumination in one direction. Maximum recessed depth 15-1/8". Custom length (> 35 feet) plenum rated wall control cables (4 for MRR-12640; 2 for MRR12642). Specify length in feet.

LEFT

5-5/8” 4-1/2” 4-11/16” (143mm) (114mm) (119mm)

RIGHT

FOOT

4-11/16” (119mm)

ON • OFF

ON • OFF

Lighting Innovators Since 1895 313-259-6400 • www.kirlinlighting.com • Detroit, MI USA

Lighting Innovators Since 1895 313-259-6400 • www.kirlinlighting.com • Detroit, MI USA

Popular Options

HEAD

4-1/2” (114mm)

2-1/2” (64mm)

-94 -99 -IP -SE

5-5/8” 2-3/16” 2-1/2” (143mm) (56mm) (64mm)

Custom color self-flanged flare trim instead. Consult factory. Special modification. Consult factory. IP65 rated trim and lens. Fixtures modified for seismic anchorage (by others). Meets California OSHPD and International Building Codes. Consult factory.

(See specification sheets for availability and details.) www.kirlinlighting.com

2-3/16” (56mm)


SECTION III: motorized exam lighting Typical Side View: MRR-12640 in Patient Room 4’ [112cm]

LUMINAIRES

Typical Side View: MRR-12640 in NICU 4’ [112cm]

CONTROL CABLE 35’ [1067cm]

2’ 8‘’ [81cm]

23° (35° Max)

WALL CONTROL & BACK BOX

22° (35° Max)

OPTe MED™

30°

SITE

8’ [244cm]

8’ [244cm] 3’ 6” [107cm]

3’ [91cm]

3’ 6” [107cm]

3’ 4” [101cm] Front View

Side View

Typical Side View: MRR-12642 in Patient Room LUMINAIRE

CONTROL CABLES 35’ [1067cm]

oG

Bi

d™ ar

OPTeCOLOR™ LEDs

WALL CONTROL & BACK BOX

Optional 15° bottom pan (Option -81) allows lighthead to be tilted up to 50° for high angle illumination or to accommodate fixture location further from the bed.

SITE

8’ [244cm]

3.5’ [107cm]

3’ [91cm]

Footcandle Distribution Data: MRR-12640 (Two Light System) 4' Spacing 8990 2150 160

8' Ceiling:

6670 2460 200

60

3' Work Plane 8990 fc 3'4" Work Plane 10000 fc

5110 2550 240

60

3' Work Plane 3'4" Work Plane

9' Ceiling:

Photometric testing by I.T.L. (Boulder, CO) I.T.L. Test No. 83197

6670 fc 7330 fc

60

3' Work Plane 3'4" Work Plane

10' Ceiling:

5110 fc 5570 fc

Footcandle Distribution Data: MRR-12642 (One Light System) 5610

8' Ceiling:

920

70

3' Work Plane 3'4" Work Plane

www.kirlinlighting.com

3900 1150

30

5610 fc 6420 fc

9' Ceiling:

90

2870 1250 110

30

3' Work Plane 3'4" Work Plane

3900 fc 4370 fc

10' Ceiling:

30

3' Work Plane 3'4" Work Plane

2870 fc 3160 fc Page 43


SECTION IV: shower lights

(recessed Deadfront)

A SAFER ENVIRONMENT • Dead-front electrically non-conductive trims standard. • Higher light levels provided, ensuring effective patient bathing and shower cleaning/maintenance. • Impact resistant lenses and reinforced trims provide safety for patient and staff. • Fully gasketed trims reduce moisture intrusion into recessed housing.

DESIGNED SPECIFICALLY FOR THE DEMANDS OF SHOWERS

• Fully gasketed trims. Wet, damp or dry locations (covered ceilings) listing. • Corrosion resistant all-aluminum construction results in components operating 25% cooler, extending every component life by 50%. • KIRLIN exclusive acrylic enamel finish protects aluminum from corrosion and exceeds ASTM 1000 hour salt spray test. • LEDs produce up to 80% less heat than traditional light sources, significantly reducing the load on hospital HVAC systems. • Shallow and super shallow housings for easier installation in crowded plenums.

IP65

IP65 trims protect against pathogens passing through the trim, either into the plenum or into the room environment.

DEPENDABILITY and REDUCED OPERATING COSTS • Long LED life, up to 90,000 hours (L70), results in 90 fewer lamp changes over the life of the system. • Power consumption is reduced by up to 80% over traditional light sources • Fully sustainable. Modular internal components are visible and easily accessed through the aperture of the fixture. Simple lighthead / trim component change available to modify spacing criteria, if desired, anytime. Replacement components are available years into the future.

ARRA

QUALIFIED

Exclusive Five Year Warranty • Designed and Produced in U.S.A. • UL, C-UL (Canada) Listed Page 44

www.kirlinlighting.com


Section IV: shower Lights (recessed Deadfront) Design

Flare

Flare

Flare

IP65

Flare

Flare

Regressed Lens

Regressed Lens

Regressed Lens

Tamper Resistant

Super Shallow

Super Shallow

Drop Polycarbonate Trim

Drop Polycarbonate Trim

Function

Downlight

Downlight

Downlight

Downlight

Downlight

Downlight

Downlight

Downlight

Aperture (Inches)

Product #

4

6

6

7

4

5

5

5

Performance Lumens

Watts

MRR-04700-2500L

2500

35

MRR-06705-1500L

1500

15

MRR-06705-1000L

1000

11

MRR-06705-500L

500

5

MRR-06710-2500L

2500

35

MRV-07715-1500L

1500

15

MRV-07715-1000L

1000

11

MRV-07715-500L

500

5

MRR-04720-1500L

1500

15

MRR-04720-1000L

1000

11

MRR-04720-500L

500

5

MRR-05725-2500L

2500

35

MRR-05730-1500L

1500

15

MRR-05730-1000L

1000

11

MRR-05730-500L

500

5

MRR-05735-2500L

2500

35

OPTIONS / luminaire ordering

Page

46

46

46

47

47

PLEASE VISIT www.kirlinlighting.com FOR KIRLIN COMPACT FLUORESCENT AND INCANDESCENT SHOWER LIGHTS IN KIRLIN’S PATIENT EXAM & HEALTHCARE LIGHTING CATALOG (BULLETIN 08HC).

ALL KIRLIN SHOWER LIGHTS ARE U.L. LISTED WET LOCATIONS

www.kirlinlighting.com

Page 45


Section IV: shower Lights

FLARE REGRESSED LENS PERFORMANCE (-2500L Series)

4”

2800 LUMENS 35W MFL (std) SC: 0.8

MRR-04700-2500L

LPW: 77

75˚

1250

60˚

2500 3750 0˚

45˚ 15˚

30˚

Cone of Light ▲ Dist.

FC

Dia.

6 8 10 12 14 16

107.0 60.5 38.7 26.9 19.7 15.1

5.0 6.6 8.3 9.9 11.6 13.2

-NFL

Lm: 2390 SC: 0.5

PERFORMANCE (-1500L Series)

6”

1721 Lumens 20W

MRR-06705-1500L MRR-06705-1000L MRR-06705-500L

90˚

MFL (std) SC: 0.8 IC

LPW: 83

90˚ 75˚

800

60˚

1600 2400 0˚

45˚ 15˚

30˚

Cone of Light ▲ Dist.

FC

Dia.

6 8 10 12 14 16

67.3 37.8 24.2 16.8 12.4 9.5

4.9 6.6 8.2 9.9 11.5 13.2

-SPT

-NFL

-WFL

Lm: 1744 SC: 0.3

Lm: 1553 SC: 0.6

Lm: 1514 SC: 1.1

-NFL

-WFL

Lm: 2888 SC: 0.5

Lm: 2379 SC: 1.0

-SPT

-NFL

-WFL

Lm: 1581 SC: 0.3

Lm: 1468 SC: 0.6

Lm: 1321 SC: 1.0

PERFORMANCE (-2500L Series)

6”

2993 LUMENS 35W MFL (std) SC: 0.8

MRR-06710-2500L

LPW: 81

90˚ 75˚

1250

60˚

2500 3750 0˚

45˚ 15˚

30˚

Cone of Light ▲ Dist.

FC

Dia.

6 8 10 12 14 16

109.0 61.6 39.4 27.4 20.1 15.4

5.0 6.7 8.4 10.0 11.7 13.4

IP65 & Tamper resistant REGRESSED LENS PERFORMANCE (-1500L Series)

7”

1495 LUMENS 20W

MRV-07715-1500L MRV-07715-1000L MRV-07715-500L

MFL (std) SC: 0.8 IC

LPW: 72

90˚ 75˚

650

60˚

1300 1950 0˚

45˚ 15˚

30˚

Cone of Light ▲ Dist.

FC

Dia.

6 8 10 12 14 16

50.7 28.5 18.2 12.7 9.3 7.1

5.1 6.8 8.5 10.2 11.9 13.6

SUPER SHALLOW FLARE REGRESSED LENS MAXIMUM PERFORMANCE (-1500L Series)

4”

1685 LUMENS 20W

MRR-04720-1500L MRR-04720-1000L MRR-04720-500L

6”

MFL (std) SC: 0.7 IC

LPW: 80

60˚

1800 2700 0˚

45˚ 15˚

2753 LUMENS

MFL SC: 0.7 LPW: 75 Page 46

75˚

900

30˚

Cone of Light ▲ Dist.

FC

Dia.

6 8 10 12 14 16

76.6 43.1 27.6 19.2 14.1 10.8

4.1 5.5 6.8 8.2 9.6 11.0

-NFL

-WFL

Lm: 1800 SC: 0.4

Lm: 1363 SC: 0.8

PERFORMANCE (-2500L Series)

35W

MRR-05725-2500L

90˚

90˚ 75˚

1500

60˚

3000 4500 0˚

45˚ 15˚

30˚

Cone of Light ▲ Dist.

FC

Dia.

6 8 10 12 14 16

126.1 70.9 45.4 31.5 23.2 17.7

4.1 5.4 6.8 8.1 9.5 10.8

www.kirlinlighting.com


Section IV: shower Lights

Drop Polycarbonate Trim

5”

MAXIMUM PERFORMANCE (-1500L Series) 1078 LUMENS 20W MFL SC: 0.7

MRR-05730-1500L MRR-05730-1000L MRR-05730-500L

LPW: 52

IC

90˚ 75˚

225

60˚

450 675 0˚

45˚ 15˚

30˚

Cone of Light ▲ Dist.

FC

Dia.

6 8 10 12 14 16

17.9 10.1 6.5 4.5 3.3 2.5

4.5 5.9 7.4 8.9 10.4 11.9

PERFORMANCE (-2500L Series)

5” 1878 LUMENS 35W WFL SC: 0.9 LPW: 54

MRR-05735-2500L

90˚ 75˚

300

60˚

600 900 0˚

45˚ 15˚

30˚

Cone of Light ▲ Dist.

FC

Dia.

6 8 10 12 14 16

24.9 14.0 9.2 6.2 4.6 3.5

5.4 7.2 8.9 10.7 12.5 14.3

▲ Cone of Light Key

Ft. Distance from fixture FC Footcandles at nadir (0°) Dia. Circle of light at 50% of FC Dia. (in ft.) shown is where FC value is half the FC at nadir.

Popular Options Input Power: SPECIFY -120 120V (50-60Hz) input and thermal protector. -277 277V (50-60Hz) input and thermal protector. -97 Specify other voltage. Consult factory.

-HC 90+ CRI instead. 2700° or 3000°K only. Reduces output by ~15%.

Optics

LED Power Supply

-NFL Narrow flood distribution instead. -WFL Wide flood distribution instead.

-EI

Lenses and Trims

REMOTE emergency inverter. 85% of rated lumens for -2500L or 100% for -1500L and lower. Run time: 90+ minutes. 120 or 277V, 60Hz input only. Specify voltage.

Color (CCT and CRI)

-13

-21 -23 -32

-27K Color temperature 2700°K instead. -30K Color temperature 3000°K instead. -41K Color temperature 4100°K instead.

-94 Custom color/finish. Specify. Consult factory. -CF Custom color filter (Rosco). Specify. -WA White acrylic (flat) diffuser instead.

Other -79 -99 -FS

Vandal resistant dual lens system: prismatic high strength acrylic above, clear poly below, plus tamperproof hardware, instead of standard lens and hardware. White translucent flat poly diffuser instead. Frosted tempered microprismatic lens instead. White oversize trim ring. Specify O.D.

Extension collar for ceilings up to 2-5/8 ” thick. Special modification. Consult factory. In-line fusing.

(See specification sheets for availability and details.)

Luminaire Ordering EXAMPLE MUST SPECIFY

OPTIONAL

Product Number

Voltage

Options

MRR-06705-1500L MRR-06705-1000L MRR-06705-500L

-120 (120 volts) -277 (277 volts) -97 (Specify other)

See “Options” above

Ordering Example: MRR-06705-1500L-120-21-WFL

LUMEN SERIES AVAILABLE Lumen Series Code

Nominal Lumens

-2500L

2500 Lumens

-1500L

1500 Lumens

-1000L

1000 Lumens

-500L

500 Lumens

www.kirlinlighting.com

Page 47


Section V: general LIGHTING: PUBLIC & clinical spaceS KIRLIN quality & value throughout Inconspicuous downlights with matching wall washes in round and square designs are available in four distributions from spot (-SPT) to wide flood (-WFL) and many color temperatures. Super Shallow downlights offer uniform illumination scaled down to fit in healthcare facilities’ crowded plenums. IP65 rated sealed trims and ISO 5 Class 100 rated sealed fixtures provide protection against infection while maintaining a sophisticated architectural aesthetic from various apertures with matching LookALike™ regressed lens trims. oG

IP65 sealed trim, BioGard™ antimicrobial finish

Bi

Level 2 + Protection

oG

Bi

IP65 sealed trim, vandal resistant, BioGard™ antimicrobial finish

Level 3 Protection

ISO 5/class 100 sealed “cleanroom” fixture, BioGard™ antimicrobial finish

IP65

d™ ar

oG

Bi

d™ ar

d™ ar

IP65

VR

IP65

ISO 5 CLASS

Level 2 Protection

100

CLEANROOM

Section V: general LIGHTING: PUBLIC & CLINICAL SPACES Function

Application

Aperture (Inches)

Product #

Performance Lumens

Watts

MRR-04800-1500L

1500

15

MRR-04800-1000L

1000

11

MRR-04800-500L

500

5

MRR-04802-1500L

1500

15

MRR-04802-1000L

1000

11

MRR-04802-500L

500

5

MRS-04803-1500L

1500

15

MRS-04803-1000L

1000

11

MRS-04803-500L

500

5

MRS-04804-1500L

1500

15

MRS-04804-1000L

1000

11

MRS-04804-500L

500

5

MRR-06805-5000L

5000

55

MRR-06805-3500L

3500

42

MRR-06805-2500L

2500

35

Page

DOWNLIGHTING and wall washing: round and square Downlight Open Appearance

Wall Wash Open Appearance

Downlight Open Appearance

Wall Wash Open Appearance

Downlight Open Appearance

Page 48

Nurse Station Admissions

Lobby Cafeteria

Conference Room Waiting Room

Corridor Auditorium

Conference Room Lobby

4

4

4

4

6

50

www.kirlinlighting.com


Section V: general LIGHTING: PUBLIC & CLINICAL SPACES Function

Application

Aperture (Inches)

Product #

Performance Lumens

Watts

MRR-06810-5000L

5000

55

MRR-06810-3500L

3500

42

MRR-06810-2500L

2500

35

MRR-06815-5000L

5000

55

MRR-06815-3500L

3500

42

MRR-06815-2500L

2500

35

MRR-04820-1500L

1500

15

MRR-04820-1000L

1000

11

MRR-04820-500L

500

5

MRR-05825-2500L

2500

35

MRR-07830-1500L

1500

15

MRR-08835-5000L

5000

55

MRR-08835-3500L

3500

42

MRR-08835-2500L

2500

35

MRV-07840-1500L

1500

15

MRV-08845-5000L

5000

55

MRV-08845-3500L

3500

42

MRV-08845-2500L

2500

35

Page

DOWNLIGHTING and wall washing Wall Wash Open Appearance

Downlight Regressed Lens

Downlight Super Shallow

Downlight Super Shallow

Hallway Registration

Dining Room Auditorium

Canopy Nurse Station

Entrance Kitchen

6

6

4

5

50

51

LEVEL 2 protection: IP65 sealed trim, BioGard™ antimicrobial finish Downlight IP65 BioGard™ Downlight IP65 BioGard™

Soffit Locker Room

Wet Location Canopy

7

8

51

LEVEL 2+ protection: IP65 sealed trim, vandal resistant, BioGard™ antimicrobial finish Downlight IP65 Tamper Resistant BioGard™ Downlight IP65 Tamper Resistant BioGard™

Psychiatric ED

Psychiatric Trauma

7

8

52

LEVEL 3 protection: ISO 5/class 100 sealed “cleanroom” fixture, BioGard™ antimicrobial finish Downlight ISO 5/Class 100 Cleanroom BioGard™ Downlight ISO 5/Class 100 Cleanroom BioGard™

Operating Room ICU / NICU / PICU

Hybrid OR Operating Room

7

8

MRR-07850-1500L

1500

15

MRR-08855-5000L

5000

55

MRR-08855-3500L

3500

42

MRR-08855-2500L

2500

35

Popular Options and Luminaire Ordering Scenic Panel: 2’ x 2’ Building Block Configuration

53

24

MRP-22295

SCENIC PANEL IMAGES, CONFIGURATIONS, product specification guide and Options www.kirlinlighting.com

52

20

54

55-57 Page 49


Section V: general LIGHTING: PUBLIC & clinical spaceS PERFORMANCE (-1500L Series)

Downlight

4” 1538 LUMENS 20W MFL (std)

MRR-04800-1500L MRR-04800-1000L MRR-04800-500L

SC: 0.8 IC

LPW: 74

90˚

2400 0˚

Square Downlight

MRR-04802-1500L MRR-04802-1000L MRR-04802-500L

Square Wall Wash

Wall Wash

45˚ 15˚

30˚

Dist.

FC

Dia.

6 8 10 12 14 16

64.9 36.5 23.4 16.2 11.9 9.1

4.9 6.6 8.2 9.9 11.5 13.2

-SPT

-NFL

Lm: 1629 SC: 0.3

Lm: 1428 SC: 0.6

PERFORMANCE (-1500L Series) 90˚

4”

4”

1375 Lumens

550

20W

1100

LPW: 66 IC

1650 0˚

75˚ 60˚ 45˚ 15˚

30˚

MAXIMUM PERFORMANCE (-1500L Series) 1579 LUMENS 20W MFL (std)

MRS-04803-1500L MRS-04803-1000L MRS-04803-500L

SC: 0.8 IC

LPW: 75

90˚ 75˚

850

60˚

1700 2550 0˚

45˚ 15˚

30˚

Cone of Light ▲ Dist.

FC

Dia.

6 8 10 12 14 16

72.6 40.8 26.1 18.1 13.3 10.2

4.6 6.1 7.7 9.2 10.7 12.3

-SPT

-NFL

Lm: 1704 SC: 0.3

Lm: 1434 SC: 0.6

MAXIMUM PERFORMANCE (-1500L Series) 90˚

MRS-04804-1500L MRS-04804-1000L MRS-04804-500L

1385 Lumens

500

20W

1000

LPW: 66 IC

1500 0˚

75˚ 60˚ 45˚ 15˚

30˚

MAXIMUM PERFORMANCE (-5000L Series)

6”

Downlight

60˚

1600

4”

4746 LUMENS 55W MFL (std)

MRR-06805-5000L MRR-06805-3500L MRR-06805-2500L

SC: 0.8 LPW: 82

90˚ 75˚

2200

60˚

4400 6600 0˚

45˚ 15˚

30˚

Cone of Light ▲ Dist.

FC

Dia.

6 8 10 12 14 16

175.1 98.5 63.1 43.8 32.2 24.6

5.2 6.9 8.6 10.3 12.0 13.7

-SPT

-NFL

-WFL

Lm: 4893 SC: 0.3

Lm: 4892 SC: 0.5

Lm: 4009 SC: 0.9

MAXIMUM PERFORMANCE (-5000L Series)

6”

Wall Wash

75˚

800

Cone of Light ▲

90˚

MRR-06810-5000L MRR-06810-3500L MRR-06810-2500L

Page 50

4141 Lumens

1500

55W

3000

LPW: 72

4500 0˚

75˚ 60˚ 45˚ 15˚

▲ Cone of Light Key

Ft. Distance from fixture FC Footcandles at nadir (0°) Dia. Circle of light at 50% of FC Dia. (in ft.) shown is where FC value is half the FC at nadir.

30˚

www.kirlinlighting.com


Section V: general LIGHTING: PUBLIC & clinical spaceS MAXIMUM PERFORMANCE (-5000L Series)

Downlight

6” 4897 LUMENS 55W MFL (std)

MRR-06815-5000L MRR-06815-3500L MRR-06815-2500L

SC: 0.8 LPW: 82

90˚ 75˚

2500

60˚

5000 7500 0˚

45˚ 15˚

30˚

1685 LUMENS

Super Shallow Downlights

20W MFL (std) SC: 0.7 FLARE TRIM

IC

LPW: 80

90˚ 75˚

900

60˚

1800 2700 0˚

FC

Dia.

6 8 10 12 14 16

182.0 102.0 65.5 45.5 33.4 25.6

5.0 6.6 8.3 9.9 11.6 13.3

-WFL

Lm: 4989 SC: 0.6

Lm: 4161 SC: 1.1

45˚ 15˚

30˚

Cone of Light ▲ Dist.

FC

Dia.

6 8 10 12 14 16

76.6 43.1 27.6 19.2 14.1 10.8

4.1 5.5 6.8 8.2 9.6 11.0

-NFL

-WFL

Lm: 1800 SC: 0.4

Lm: 1363 SC: 0.8

PERFORMANCE (-2500L Series)

5” 2409 LUMENS 35W WFL SC: 1.2

MRR-05825-2500L

Dist.

-NFL

MAXIMUM PERFORMANCE (-1500L Series)

4”

MRR-04820-1500L MRR-04820-1000L MRR-04820-500L

Cone of Light ▲

FLAT TRIM

LPW: 66

90˚ 75˚

350

60˚

700 1050 0˚

45˚ 15˚

30˚

Cone of Light ▲ Dist.

FC

Dia.

6 8 10 12 14 16

31.6 17.8 11.4 7.9 5.8 4.5

6.9 9.3 11.3 13.9 16.2 18.5

▲ Cone of Light Key

Ft. Distance from fixture FC Footcandles at nadir (0°) Dia. Circle of light at 50% of FC Dia. (in ft.) shown is where FC value is half the FC at nadir.

Level 2 Protection

oG

Bi

IP65 sealed trim, BioGard™ antimicrobial finish

7”

20W

IP65 Downlights

MFL (std) SC: 0.8 IC

LPW: 83

8”

90˚ 75˚

800

60˚

1600 2400 0˚

45˚ 15˚

55W MFL (std)

www.kirlinlighting.com

30˚

Cone of Light ▲ Dist.

FC

Dia.

6 8 10 12 14 16

67.3 37.8 24.2 16.8 12.4 9.5

4.9 6.6 8.2 9.9 11.5 13.2

-SPT

-NFL

-WFL

Lm: 1744 SC: 0.3

Lm: 1553 SC: 0.6

Lm: 1514 SC: 1.1

MAXIMUM PERFORMANCE (-5000L Series) 5310 LUMENS

MRR-08835-5000L MRR-08835-3500L MRR-08835-2500L

IP65

PERFORMANCE (-1500L Series) 1721 Lumens

MRR-07830-1500L

d™ ar

SC: 0.8 LPW: 94

90˚ 75˚

2500

60˚

5000 7500 0˚

45˚ 15˚

30˚

Cone of Light ▲ Dist.

FC

Dia.

6 8 10 12 14 16

188.0 106.0 67.8 47.1 34.6 26.5

5.1 6.7 8.4 10.1 11.8 13.5

-NFL

-WFL

Lm: 5298 SC: 0.5

Lm: 4416 SC: 1.1

Page 51


Section V: general LIGHTING: PUBLIC & clinical spaceS Level 2 + Protection

oG

Bi

IP65 sealed TRIM, VANDAL RESISTANT, BioGard™ antimicrobial finish

7”

MFL (std) SC: 0.8 LPW: 72

90˚ 75˚

650

60˚

1300 1950 0˚

45˚ 15˚

30˚

Cone of Light ▲ Dist.

FC

Dia.

6 8 10 12 14 16

50.7 28.5 18.2 12.7 9.3 7.1

5.1 6.8 8.5 10.2 11.9 13.6

-SPT

-NFL

-WFL

Lm: 1581 SC: 0.3

Lm: 1468 SC: 0.6

Lm: 1321 SC: 1.0

IC

8” MAXIMUM PERFORMANCE (-5000L Series) 4857 LUMENS 55W MFL (std)

MRV-08845-5000L MRV-08845-3500L MRV-08845-2500L

LPW: 81

90˚ 75˚

1800

60˚

3600 5400 0˚

45˚ 15˚

30˚

Cone of Light ▲ Dist.

FC

Dia.

6 8 10 12 14 16

147.0 82.5 52.8 36.7 26.9 20.6

5.1 6.8 8.5 10.2 11.9 13.6

Level 3 Protection

Lm: 4749 SC: 0.5

Lm: 4432 SC: 1.1

oG

d™ ar

IP65

ISO 5

100

CLEANROOM

PERFORMANCE (-1500L Series) 1721 Lumens 20W MFL (std) SC: 0.8 LPW: 83

MRR-07850-1500L

-WFL

Bi

ISO 5/class 100 sealed “cleanroom” fixture, BioGard™ antimicrobial finish

7”

-NFL

CLASS

IP65 and Tamper Resistant Downlights

20W

SC: 0.8

Cleanroom Rated Downlights

VR

PERFORMANCE (-1500L Series) 1495 LUMENS

MRV-07840-1500L

IP65

d™ ar

90˚ 75˚

800

60˚

1600 2400 0˚

45˚ 15˚

30˚

Cone of Light ▲ Dist.

FC

Dia.

6 8 10 12 14 16

67.3 37.8 24.2 16.8 12.4 9.5

4.9 6.6 8.2 9.9 11.5 13.2

-SPT

-NFL

Lm: 1744 SC: 0.3

Lm: 1553 SC: 0.6

IC

8” MAXIMUM PERFORMANCE (-5000L Series) 5310 LUMENS 55W MFL (std) SC: 0.8

MRR-08855-5000L MRR-08855-3500L MRR-08855-2500L

Page 52

LPW: 94

90˚ 75˚

2500

60˚

5000 7500 0˚

45˚ 15˚

30˚

Cone of Light ▲ Dist.

FC

Dia.

6 8 10 12 14 16

188.0 106.0 67.8 47.1 34.6 26.5

5.1 6.7 8.4 10.1 11.8 13.5

-NFL

-WFL

Lm: 5298 SC: 0.5

Lm: 4416 SC: 1.1

2013 IES Progress Report Selection

www.kirlinlighting.com


Section V: general LIGHTING Input Power

separately. Order LPS-1220A (0-10V analog with 100-0.2% PWM dimming). Available for -1500L, -2500L and -5000L lumen series luminaires only. See below and LPS-1220A specification sheet and Owner’s Manual at www.kirlinlighting.com.

-120 120V (50-60Hz) input and thermal protector. -277 277V (50-60Hz) input and thermal protector. -97 Specify other voltage. Consult factory.

LED Power Supply -29 Two wire full range (100-1%) PWM dimming instead (Lutron). 120V only. Not available with -EI. -39 Three wire full range (100-1%) PWM dimming instead (Lutron). -EI REMOTE emergency inverter for 45% of rated lumens for -5000L, 55% for -3500L, 85% for -2500L or 100% for -1500L and lower. Run time: 90+ minutes. 120 or 277V, 60 Hz input only. Specify voltage. Not for use with -SS SmartSupply™ driver or with Option -29. -EM INTERNAL emergency battery pack. Delivers 500 lumens. Run time: 90+ minutes. -EMH INTERNAL emergency battery pack. Delivers 1000 lumens. Run time: 90+ minutes. Marked spacings installation may be required; refer to individual specification sheet. -ER REMOTE emergency battery pack. Delivers 500 lumens. Run time: 90+ minutes. -ERH REMOTE emergency battery pack. Delivers 1000 lumens. Run time: 90+ minutes. -SS Remote mounted Kirlin SmartSupply™ driver (instead of standard internal driver), sold

popular options

Color (CCT and CRI) -27K -30K -41K -HC

Color temperature 2700°K instead. Color temperature 3000°K instead. Color temperature 4100°K instead. 90+ CRI instead. 2700° or 3000°K only. Reduces output by ~15%.

-NFL Narrow flood distribution. (0.5 SC) -SPT Spot distribution. (0.4 SC) -WFL Wide flood distribution. (1.0 SC)

Custom color filter (Rosco). Specify. Green acrylic filter mounted in lens assembly. Custom filter mounted in lens assembly. Specify.

Other

Lenses and Trims

-17 -21 -23 -30 -31

Filter -CF -GE -XF

Optics (-MFL Standard)

-13

-32 White oversize trim ring. Specify O.D. -35T Natural aluminum acrylic (silver) enameled trim. -45 Gasket between trim flange and ceiling. -46 Gasket between trim and lens. -70 SofTex Clear self-flanged cone. (CP x .93) -94 Custom color/finish. Specify. Consult factory. -BG Antimicrobial Kirlin BioGard™ white (only) trim finish. -DF Electrically isolated “dead front” gasketed trim. -WA White acrylic (flat) diffuser instead.

Vandal resistant dual lens system: prismatic high strength acrylic above, clear poly below with tamperproof hardware, instead of standard lens and hardware. Prismatic high strength acrylic lens instead. White translucent flat poly diffuser instead. Frosted tempered microprismatic lens instead. All white acrylic enameled cone. White acrylic enameled flange (only).

-79 -99 -FD -FS

Extension collar for ceilings up to 2” thick. Special modification. Consult factory. Dual circuit fusing. For use only with Option -EI and either -5000L or -3500L lumen series. In-line fusing. Not for use with Option -EI and either -5000L or -3500L lumen series: See -FD instead.

(See specification sheets for availability and details.)

SmartSupply™ REMOTE DIMMING DRIVER - OPTIONAL • Full range 100% to 0.2% dimming and 3 dimming zones. • Drives up to (12) -1500L, (6) -2500L or (3) -5000L luminaires. • Over wattage, cross channel, and electrical fast transient (EFT) protection. • Input: 115-277VAC / 50-60Hz rated. Dedicated 120VAC input recommended. For 277VAC input, proper line filtering and surge protection must be provided (by others). Maximum continuous input voltage is 290VAC. • Requires 16 AWG (minimum) twisted pair shielded wire from SmartSupply™ to luminaires. • FIVE YEAR Limited Warranty.

LPS-1220A

See LPS-1220A Owner’s Manual for more information including compatible controls and wiring diagrams.

Luminaire Ordering EXAMPLE MUST SPECIFY

OPTIONAL

Product Number

Voltage

Options

MRR-06805-5000L MRR-06805-3500L MRR-06805-2500L

-120 (120 volts) -277 (277 volts) -97 (Specify other)

See “Options” above

Ordering Example: MRR-06805-5000L-120-30K-NFL

LUMEN SERIES AVAILABLE Lumen Series Code

Nominal Lumens

Lumen Series Code

Nominal Lumens

-5000L

5000 Lumens

-1500L

1500 Lumens

-3500L

3500 Lumens

-1000L

1000 Lumens

-2500L

2500 Lumens

-500L

500 Lumens

www.kirlinlighting.com

Page 53


Scenic Panel system: MRP-22295 SERIES* • Selection of beautiful smooth panel artwork attractively and uniformly illuminated • Wave guide lens provides superior uniform illumination • Regressed trim provides architectural “skylight” effect • Ultra-shallow (2”) recessed aluminum housing

• • • •

IC

Lays into 2’ x 2’ grid ceiling 100-10% dimming 60,000 hours (L70) life Also compatible with SmartSupply™ LPS-0700A. See page 57.

MRP-22295*

Regressed bevel provides architectural “skylight” effect.

2’ x 2’ Scenic Panels create a soothing and attractive luminous ceiling.

Ultra-shallow (2”) aluminum housing requires minimal plenum space.

*Not for use in MRI applications. See Section I: MRI Lighting Systems MRP-22290 for MRI compatible Scenic Panel systems.

Page 54

www.kirlinlighting.com


Scenic Panel system: Images Artwork Select artwork by adding the option code (i.e., -A01) of the respective artwork. For custom artwork, use Option -A99.

-A01

-A02

-A03

Custom Artwork (Customer supplied*)

-A05

-A06

-A04

Custom Artwork Preferred Image Resolution 1800 x 1800 pixels (or greater) per 24” x 24” panel. See “Overall Size and Orientation” table on page 56 for preferred image resolution for each configuration.

-A99

* For custom artwork, customer is responsible for supplying the artwork and obtaining the appropriate usage rights.

Dividing and Cropping Artwork When specifying size, orientation and artwork, consider how the image will be divided and cropped. For example:

-4x4

-6x4

-4x6

To see how your artwork will divided and cropped, consult factory. www.kirlinlighting.com

Page 55


Scenic Panel system: Panel Configurations 1. 2. 3. 4.

Use MRP-22295* as base catalog number, then add configurations and selections as follows. Choose overall size and orientation of the display using the “Overall Size and Orientation” table below. Select artwork with option codes (i.e., -A01). Consider how the artwork will be displayed. See “Dividing and Cropping Artwork”. For SmartSupply™ LPS-0700A remote driver instead, use Option -SS and order the appropriate number of LPS-0700A remote drivers separately. See page 57 for more information. 5. Following the submission of your order, and before production, you will receive a proof for your review and approval.

Overall Size and Orientation Landscape

Portrait

Option

Preferred Resolution (Pixels)

1

-2x2

1800 x 1800

2’ x 4’

2

-4x2

3600 x 1800

4’ x 4’

4

-4x4

3600 x 3600

4’ x 6’

6

-6x4

5400 x 3600

6’ x 6’

9

-6x6

5400 x 5400

6’ x 8’

12

-8x6

7200 x 5400

8’ x 8’

16

-8x8

7200 x 7200

Nominal Dimensions

Fixture Qty

2’ x 2’

Custom Size

Arrangement

Arrangement

Option

Preferred Resolution (Pixels)

-2x4

1800 x 3600

-4x6

3600 x 5400

-6x8

5400 x 7200

-9x9 Specify number of panels and orientation of artwork.

*Not for use in MRI applications. See Section I: MRI Lighting Systems MRP-22290 for MRI compatible Scenic Panel systems.

Page 56

www.kirlinlighting.com


SCENIC PANEL product SPECIFICATION EXAMPLE MRP-22295 -120 -4x6 -A01

Example: Scenic Panel Product Number

Specify Voltage

Artwork Option

Size and Orientation Option*

*-4x6 is not the same as -6x4, see page 56.

POPULAR SCENIC PANEL Options Input Power: SPECIFY

LED Power Supply

-120 120V (50-60Hz) input and thermal protector. -277 277V (50-60Hz) input and thermal protector. -97 Specify other voltage. Consult factory.

-29 Two wire full range (100-1%) PWM dimming instead (Lutron). 120V only. -39 Three wire full range (100-1%) PWM dimming instead (Lutron).

-SS

Remote mounted Kirlin SmartSupply™ driver (instead of standard internal driver), sold separately. Order LPS-0700A (0-10V analog with 100-0.2% PWM dimming). See below and refer to LPS-0700A specification sheet and Owner’s Manual at www.kirlinlighting. com.

SCENIC PANEL: SmartSupply™ DRIVER - OPTIONAL • Full range 100% to 0.2% dimming and 3 dimming zones. See page 26 or consult factory for compatible controls. • Over wattage, cross channel, and electrical fast transient (EFT) protection. • Input: 115-277VAC / 50-60Hz rated. Dedicated 120VAC input recommended. For 277VAC input, proper line filtering and surge protection must be provided (by others). Maximum continuous input voltage is 290VAC. • Requires 16 AWG (minimum) twisted pair shielded wire from SmartSupply™ to luminaires. • FIVE YEAR Limited Warranty.

LPS-0700A

With Scenic Panels (20W) (12) Channels (Circuits) Maximum Distance Per Channel

www.kirlinlighting.com

(1) scenic panel / channel Up to (12) scenic panels / SmartSupply™ 150 feet

Page 57


Section vi: NightLights / ChartLights & StepLights

TYPE IC

IC Type IC standard on all models.

Full spectrum of optional colors, including Red/Amber (Option -RA) to maintain melatonin levels and circadian rhythm.

The most comprehensive collection of NightLights, ChartLights, StepLights and options available.

Fastener-free faceplate (Option -FF) available on most models.

Double faced (thru-the-wall) NightLight illuminates two adjoining spaces. Adjustable to fit various wall thicknesses. Lenses optional instead of louvers. Applications: Patient Room / Patient Room Corridor / Patient Room Bathroom / Patient Room

Page 58

Maximum security NightLight. Optional tamper resistant designs (Option -26) available on most other models. Applications: Public spaces and psychiatric wards.

www.kirlinlighting.com


Section vi: NightLights / ChartLights & StepLights Design

Function

TYPE IC

Aperture

Product #

Watts

Page

NightLights / ChartLights - Type ic Round

Lensed

NightLight/ ChartLight

5

MNR-05900

6

Square

Lensed

NightLight/ ChartLight

5x5

MNS-05904

6 60

Rectangle Lensed

NightLight/ ChartLight

3x5

MNT-03906

5

Bricklight

Louvered

NightLight/ ChartLight

3x8

MNT-03908

6

Single Face

Louvered

NightLight

7 x 10

MNT-07912

6

NightLights - Type ic

61

Double Face

Louvered

NightLight

7 x 10

MNT-07914

12

Maximum Security Louvered

NightLight

7x9

MNV-07916

6

Round

Lensed

StepLight

5

MNR-05920

6

Square

Lensed

StepLight

5x5

MNS-05924

6

61

StepLights - type ic

62

Rectangle Lensed

StepLight

3x5

MNT-03926

5

Bricklight

StepLight

3x8

MNT-03928

6

Louvered

Popular Options and Luminaire Ordering

63

Exclusive Five Year Warranty • Designed and Produced in U.S.A. • UL, C-UL (Canada) Listed

www.kirlinlighting.com

Page 59


Section VI: NightLights / ChartLights

IC

5”

Popular Trim Options

Option Code

Fastener Free Face

-FF

Tamper Resistant Fasteners

-26

Popular Trim Options

Option Code

Fastener Free Face

-FF

Tamper Resistant Fasteners

-26

Popular Trim Options

Option Code

Tamper Resistant Fasteners

-26

Popular Trim Options

Option Code

Tamper Resistant Fasteners

-26

MNR-05900

5” x 5”

Lensed

MNS-05904

3” x 5”

MNT-03906

3” x 8”

Louvered

MNT-03908

Page 60

www.kirlinlighting.com


Section VI: NightLights  7” x 10”

Single Face Louvered

IC

Popular Trim Options

Option Code

Prismatic Lens Instead

-17

Tamper Resistant Fasteners

-26

On-Off Switch

-34

GFCI Outlet

-GF

Popular Trim Options

Option Code

Tamper Resistant Fasteners

-26

Prismatic Lens on One Side Louver on Other Side

-L1

Prismatic Lens on Both Sides

-L2

On-Off Switch on One Side

-S1

On-Off Switch on Both Sides

-S2

GFCI Outlet on One Side

-G1

GFCI Outlet on Both Sides

-G2

MNT-07912

7” x 10”

Double Face Louvered

MNT-07914

NightLights - Maximum security 7” x 9”

Single Face Louvered

IC

Popular Trim Options

Option Code

Dual Lens - Polycarbonate Lens Plus High Strength Acrylic Prismatic Lens Instead

-17

MNV-07916

www.kirlinlighting.com

Page 61


Section VI: StepLights

IC

5”

Popular Trim Options

Option Code

Fastener Free Face

-FF

Tamper Resistant Fasteners

-26

Popular Trim Options

Option Code

Fastener Free Face

-FF

Tamper Resistant Fasteners

-26

Popular Trim Options

Option Code

Tamper Resistant Fasteners

-26

Popular Trim Options

Option Code

Tamper Resistant Fasteners

-26

MNR-05920

5” x 5”

Lensed

MNS-05924

3” x 5”

MNT-03926

3” x 8”

MNT-03928

Page 62

www.kirlinlighting.com


Section VI: NightLight / ChartLight & StepLight Options Input Power: SPECIFY

-26

-120 120V (50-60Hz) input. (Required for Options -34, -GF or -HD) -277 277V (50-60Hz) input. -97 Other voltage input. Consult factory.

-34

LED Power Supply

-G1

-EI

Remote emergency inverter for 100% of rated lumens. Run time: 90+ minutes. 120 or 277V, 60 Hz input only. Specify voltage. -HW Higher light output. Approximately doubles light output.

-G2 -GF

Filter Colors -BL -GE -OR -RA -YE -CF

Blue filter. Green filter. Orange filter. Red/Amber filter. Yellow filter. Custom color filter (Rosco). Specify.

-H1 -H2 -HD

Lenses and Trims -17

.187” high strength prismatic acrylic lens with door instead of louvers. For MNV-07916 .25” clear polycarbonate with .187” high strength acrylic prismatic lensed faceplate instead.

-L1

-L2 .187” high strength acrylic prismatic lens and door instead on both sides. -S1 With hospital grade push button on-off switch installed on one side. Controls both lamps. Indoor use. Rated 120V only. Must add Option -120. -S2 With one hospital grade push button on-off switch installed on each side. Controls each side separately. Use with -84. Indoor use. Rated 120V only. Must add Option -120.

Faceplate secured to housing with two center pin tamper resistant screws. Tamper resistant tool included. With hospital grade push button on-off switch. Indoor use. Rated 120V only. Must add Option -120. With duplex hospital grade GFCI installed on one side. White. Indoor use. Rated 120V only. Must add Option -120. With duplex hospital grade GFCI installed on both sides. White. Indoor use. Rated 120V only. Must add Option -120. With duplex hospital grade GFCI installed. Indoor use. Rated 120V only. Must add Option -120. With duplex hospital grade receptacle on one side. White. Indoor use. Rated 120V only. Must add Option -120. With duplex hospital grade receptacle on both sides. White. Indoor use. Rated 120V only. Must add Option -120. With duplex hospital grade receptacle installed. Indoor use. Rated 120V only. Must add Option -120. .187” high strength acrylic prismatic lens and door instead on one side. Louvers on other side.

Faceplate Finishes -35 -37 -38 -94

Natural aluminum (silver) acrylic enamel. Dark Bronze acrylic enamel. Black acrylic enamel. Custom color/finish. Specify. Consult factory.

Other -84 -99 -FF

Wired for two circuits. Special modification. Consult factory. Fastener free faceplate / trim. No visible hardware. (UL Damp listed only)

Optional filter colors

Circadian Red / Amber Option -RA

Tiger Orange Option -OR

Wolverine Maize Option -YE

Spartan Green Option -GE

Lion Blue Option -BL

Custom Color Filter Option -CF

(See specification sheets for availability and details.)

NightLights / ChartLights & StepLights: Ordering

MUST SPECIFY

OPTIONAL

Product Number

Voltage

Options

MNT-07912

-120 (120 volts) -277 (277 volts) -97 (Specify other)

See “Options” above

www.kirlinlighting.com

Ordering Example: MNT-07912-120-34-GF

Page 63


Our Legacy of Leadership in Healthcare Lighting 1970’s

With the assistance of Dr. Michael DeBakey of the Baylor College of Medicine, Kirlin pioneers recessed motorized medical lighting.

1980’s

Kirlin takes the lead in MRI lighting, utilizing our exclusive aluminum housings and trims

1990’s

Kirlin patents the INFRALITE® Motorized Remote Controlled Lighting Systems.

2000’s

Kirlin introduces our first sealed & gasketed (IP65) downlights and exam lights and LED NightLights

2011

Kirlin pioneers the first and only turn-key LED lighting system for MRI suites called SmartLED™ MRI Lighting.

2015

Kirlin introduces OPTeLED™, the first high-performance motorized LED lighting system.

2016

Award winning INFRALED® 60 launched, taking LDR lighting to the next level... Delivering cool light at angles up to 60° utilizing Kirlin’s exclusive OPTeCOLOR™ medical grade LEDs. INFRALED® for ICU, cardiac cath, patient exams also introduced and specified globally.

ARRA

QUALIFIED

COMPLIANT

Designed, Manufactured and Assembled in the United States of America

3401 East Jefferson Avenue, Detroit MI 48207-4232 313-259-6400 • FAX: 313-259-3121 • www.kirlinlighting.com • info@kirlinlighting.com


Issuu converts static files into: digital portfolios, online yearbooks, online catalogs, digital photo albums and more. Sign up and create your flipbook.