JC Penney Puerto Rico

Page 1

EXISTING FLOOR TO REMAIN NEW TRANSITION STRIP. TYP. ALL AROUND NEW SHOP AREA NEW TRACK LIGHTING TYP. REFER TO ELEC. AND JCP FIXTURE PLAN FOR EXACT LOCATIONS

INSTALL NEW BURNISHED CONC. FLOORING AT NEW SHOP ONLY. REFER TO SPEC. FOR DETAILS

INSTALL NEW CORNER GUARDS AT COLUMNS TYP. REFER TO SPECS. FOR DETAILS EXIST. GENERAL LIGHTING TO REMAIN. ADJUST AS REQUIRED TO ACCOMMODATE NEW TASK LIGHTING. SEE ELEC. DRAWINGS VERIFY EXACT LOCATIONS IN FIELD.

EXISTING GYP. BD. WALLS WITH STANDARDS TO REMAIN. PAINT PER DECOR DRAWINGS. WALLS WITH EXISTING SLATWALL TO RECEIVE NEW GYP. BD. APPLIED OVER SLATWALL. PAINT PER DECOR DRAWINGS. EXISTING WALL WITH SKINWALL "TO REMAIN" AND RECEIVE NEW VINYL FILM APPLIED TO THE SKINWALL PANELS. REFER TO DECOR FINISH SCHEDULE

NEW PENDANT LIGHTING TYP. REFER TO ELEC. AND JCP FIXTURE PLAN FOR EXACT LOCATIONS

EXIST. GENERAL LIGHTING TO REMAIN. ADJUST AS REQUIRED TO ACCOMMODATE NEW TASK LIGHTING. SEE ELEC. DRAWINGS VERIFY EXACT LOCATIONS IN FIELD.

EXIST. ACOUSTICAL TILE AND GRID TO REMAIN. REPLACE ANY STAINED OR DAMAGED TILES AT NEW SHOP AREA ONLY.

PROVIDE NEW VINYL WALL BASE FOR WALLS AND COLUMNS TYP.

EXIST. ACOUSTICAL TILE AND GRID TO REMAIN. REPLACE ANY STAINED OR DAMAGED TILES AT NEW SHOP AREA ONLY. NEW TRACK LIGHTING TYP. REFER TO ELEC. AND JCP FIXTURE PLAN FOR EXACT LOCATIONS

NOTE: FIXTURES SHOWN FOR REFERENCE ONLY

6

ENLARGED LEVI CEILING

5

1/8" = 1'-0"

ENLARGED LEVI PLAN

4

1/8" = 1'-0"

ENLARGED ARIZONA CEILING 1/8" = 1'-0"

NEW CLG. GRID AND ACOUSTICAL TILE WHERE FEATURE WALL WAS REMOVED RELOCATED OR NEW HEADER LIGHTS WHERE FEATURE WALL WAS REMOVED

NEW HEADER AS REQUIRED

NEW TRANSITION STRIP. TYP. ALL AROUND NEW SHOP AREA

ENLARGED FLOOR PLANS ARIZONA & LEVIS FLOOR & CEILING PLANS

NEW TRANSITION STRIP. TYP. ALL AROUND NEW SHOP AREA INSTALL NEW CORNER GUARDS AT COLUMNS TYP. REFER TO SPECS. FOR DETAILS

NEW TRACK LIGHTING TYP. REFER TO ELEC. AND JCP FIXTURE PLAN FOR EXACT LOCATIONS

EXISTING FLOOR TO REMAIN

NEW PENDANT LIGHTING TYP. REFER TO ELEC. AND JCP FIXTURE PLAN FOR EXACT LOCATIONS INSTALL NEW CORNER GUARDS AT COLUMNS TYP. REFER TO SPECS. FOR DETAILS

EXISTING FLOOR TO REMAIN

EXIST. GENERAL LIGHTING TO REMAIN. ADJUST AS REQUIRED TO ACCOMMODATE NEW TASK LIGHTING. SEE ELEC. DRAWINGS VERIFY EXACT LOCATIONS IN FIELD.

INSTALL NEW BURNISHED CONC. FLOORING AT NEW SHOP ONLY. REFER TO SPEC. FOR DETAILS

INSTALL NEW CORNER GUARDS AT COLUMNS TYP. REFER TO SPECS. FOR DETAILS

EXIST. ACOUSTICAL TILE AND GRID TO REMAIN. REPLACE ANY STAINED OR DAMAGED TILES AT NEW SHOP AREA ONLY.

NEW CLG. GRID AND ACOUSTICAL TILE WHERE FEATURE WALL WAS REMOVED RELOCATED OR NEW HEADER LIGHTS WHERE FEATURE WALL WAS REMOVED

INSTALL NEW BURNISHED CONC. FLOORING AT NEW SHOP ONLY. REFER TO SPEC. FOR DETAILS

NEW HEADER AS REQUIRED EXISTING GYP. BD. WALLS WITH STANDARDS TO REMAIN. PAINT PER DECOR DRAWINGS. WALLS WITH EXISTING SLATWALL TO RECEIVE NEW GYP. BD. APPLIED OVER SLATWALL. PAINT PER DECOR DRAWINGS. EXISTING WALL WITH SKINWALL "TO REMAIN" AND RECEIVE NEW VINYL FILM APPLIED TO THE SKINWALL PANELS. REFER TO DECOR FINISH SCHEDULE

EXISTING GYP. BD. WALLS WITH STANDARDS TO REMAIN. PAINT PER DECOR DRAWINGS. WALLS WITH EXISTING SLATWALL TO RECEIVE NEW GYP. BD. APPLIED OVER SLATWALL. PAINT PER DECOR DRAWINGS. EXISTING WALL WITH SKINWALL "TO REMAIN" AND RECEIVE NEW VINYL FILM APPLIED TO THE SKINWALL PANELS. REFER TO DECOR FINISH SCHEDULE

PROVIDE NEW VINYL WALL BASE FOR WALLS AND COLUMNS TYP.

NOTE: FIXTURES SHOWN FOR REFERENCE ONLY

3

ENLARGED ARIZONA PLAN 1/8" = 1'-0"

NOTE: FIXTURES SHOWN FOR REFERENCE ONLY

2

ENLARGED ARIZONA & LEVI CEILING 1/8" = 1'-0"

1

PROVIDE NEW VINYL WALL BASE FOR WALLS AND COLUMNS TYP.

ENLARGED ARIZONA & LEVI PLAN 1/8" = 1'-0"

A300


Turn static files into dynamic content formats.

Create a flipbook
Issuu converts static files into: digital portfolios, online yearbooks, online catalogs, digital photo albums and more. Sign up and create your flipbook.