1. LA innovation Center 2. Multi-Purpose APT 3. Mumford House Lab 2
4. Urban Food Garden
Program Used :
3
LA Innovative Community Center 4
Senior Studio (2021)
5
Design Concept Reinterpretation In a programatic way, needing of exhibition and gym, reinterpretation of staples and convention center were used as concept, combining functions and shapes and design with the flow of the circulation.
Staples Center
LA Convention Center
Emotion
6
Floor Plan
Double Lock Main Lobby Meeting Room
Kids Room
Cafe
Gym Storage
Office
Mech Room
Back of House
Exhibition
Locker Locker
P
South Entry Computer Lab
24’
48’
Bike Parking
96’
144’
240’
Scale : 1” = 1/24’
7
North Elevation North Elevation
24’
48’
96’
144’
24’
48’
96’
144’
South Elevation South Elevation
8
24’
48’
96’
144’
Total window : 3770 Total Wall : 20400 WWR : ~20% Total window : 3770 Total Wall : 20400 WWR : ~20%
240’ 240’
240’
Scale : 1” = 1/24’ Scale : 1” = 1/24’
9
Perspective Wall Section
Coping Water Membrane 6”Insulation
1 ’ Concrete Column GypsumBoard Channel
Sidings(Metal) Window Head
Conduit Mullion
Window Sill
Flooring
Water Barrier Rigid Insulation 6” Concrete Slab
Exterior Sheathing CMU 6” 8” 8”
Footings
10
Coping Water Membrane 6” Insulation
Steel top trim
1’ Concrete Column Gypsum Board Green Channel
Green Wall Panel
Conduit Water Drip Line 3/8” Wedge Anchor Water Barrier
Rigid Insulation 6” Exterior Sheathing Flooring
CMU 6” 8” 8”
6” Concrete Slab
11
Structure
Concrete Flat Plate
Concrete Thin Dome Shell
Steel Truss System (A1) 1ft x 1ft concrete column
Concrete Slab 6in. Footings
Truss System A1 (Vierendeel Truss System) Concrete slab Steel Decking Vierendeel Truss 3.5’ thickness about 80ft span
1’x1’ Concrete Column
12
13
Multi-Purpose Apartment 14
Junior Studio (2021)
15
Design Concept Intersection Location : 106 E Clark St. Champaign, IL Two different Grid Intersection of landmarks
ADA Unit Design
First Floor Plan
B
0’
Public Toilet
IT retail
Screened Trash
-5’
Indoor Amenity
Parking Lot
Office
Outdoor Amenity Bookstore
Gym Retail Indoor Garden
B’
16
32’
64’
96’
128’
160’
Prototyping & Form Study
Residential Floor Plan
Unit B
ADA
ADA
ADA
ADA
Indoor Amenity
A
A’
Unit B Unit E
Unit A Unit C
Unit D
Unit E
Unit E
Unit C
Unit A
Residential Floor Plan
32’
64’
96’
128’
160’
17
Section & Elevation North-South Section B-B’
East-West Sec
West Elevation
South Elevatio
18
ction B-B’
on
19
Rendered Perspectives
Section Render
Section showing the cut of balconies, providing views towards Southern side with park and nature.
20
East Side Perspective
Shading Devices
21
22
Mumford House Lab Sophomore Studio (2019)
23
Design Concept Observation
South Quad
Mumford House
Temple Hoyne Buell Hall
24
The purpose of this building is to create spaces for students to rest by Mumford House which is historical architectural monumental in order to have more approach to the house. My concept has strong desire of “Observing” the Mumford House from the Lab. Rest of the area on first floor is public dominated.
First Floor Plan 100' - 0" 15' - 0"
UP
18' - 0"
6' - 5 1/2" 18' - 10 83/128"
8' - 9"
35' - 0"
UP
8' - 9"
13' - 9 17/256"
8' - 10 255/256"
7' - 0"
Second Floor Plan 67' - 0" 2' - 0"
47' - 0"
7' - 11 147/256"
7' - 0"
25
Modeling & Prototyping Balloon Frame Structure Mumford House
Lath & Plaster Insulation
Finish Floor Plywood Decking Ceiling Structure Floor Joist 2x4 wall stud 8x8 Sill 2x8 Floor Joist
26
2x4 Roof Rafters Ridge Roof Sheathing Water Membrane Roof Shingles Double Top Plate Cripple Stud Header King Stud Sill Jack Stud Wall Sheathing Water Membrane
Wood Siding
Brick Based Foundation
27
3D Modeling & Design
1. Stone Footings and Concrete Slab (Basement)
2. Brick Foundation and Wall
4. Studs (Wall, Jack, King, Cripple), Header, Rough Sill, Ribbon Member
5. Double Top Plate, Rafters, Ridge, Roof Studs
28
3. 8x8 Sill Plate and First Floor Joists
6. Second Floor Joists, Plaster for first and second floor
7. Sheathing
8. Vapor Barrier
9. Insulation
10. Dry Wall, Decking
11. Exterior Wall and Roof, WIndows and Cellar Door
12. Finish Floor
29
UIUC Climate Shelter Sophomore Studio (2020)
30
31
Design
Site Map
E Gregory Dr
Gies College of Business
S 6th St
UIUC Climate Shelter located between Huff Hall and Business building. It was designed with a concept “Golden Ratio” with different heights of buildings, giving the best climate shelter based on climate research around the campus in UIUC.
32
Concept
First Concept Golden Ratio
Second Concept Grid
Third Concept Revolve-Center
Intention of design. In order to provide walls to block wind from NorthWest during winter and give shade during summer.
One Word : Golden Ratio
Location Since it’s nearby the parking lot, there aren’t cover to protect from wind and sun.
Grade + Radial
Merge + Grid
Rotate + Centralized
33
Sun Hour Diagram
Grasshopper LadyBug Sun Hour
34
35
Climate Analysis Site Microclimates The Site Microclimates
Summer Wind Analysis
Winter Wind Analysis
36
Summer 9 am cast shadow
Summer 12 pm c
Winter 9 am cast shadow
Winter 12 pm cas
cast shadow
st shadow
scale : 3 Most Unfavorable, 15 = Most Favorable
Summer 3 pm cast shadow
Summer Microclimate analysis
Winter 3 pm cast shadow
Winter Microclimate analysis
37
Emotional Render
38
Abstract Render
Ref. 39
Champaign Downtown Community Clinic 40
Group Competition (2021)
Epidemic Urbanism Prof. Swiatek John Moon, Josh Lim, Matt Werkheiser 41
Design Concept Segregation
CDCC (Champaign Downtown Community Clinic) was designed with the consideration of being “segregated” in the exam rooms so patients won’t face each other but also at the same time providing social features that comes to selective oppotunity to everyone at outdoor and indoor at separation.
Program Based
42
Segregation
Indoor Garden
Community Focused
Site Research Primarily single-family with
1110 Neil St. Champaign, IL
medium density
RESIDENTIAL
4 Bus Stops around Site Across the street from an elementary/middle school Champaign, IL Population: 87,636 Home of University of Illinois
0-20
Demographics
Demographic 100-200k 50-100k
70+ 30-50
There is not large elderly or middle aged Lots of education programs around high % young population
50-70
20-30 About 75% of population around this district has less than 50k annual income UNDER 50K
WALK BIKE
BLACK
HISPANIC ASIAN
About 50% of the area surrounding the site is African American WHITE PUBLIC TRANSPORT
Higher than city average rate of biking, carpooling, and using public transport.
DRIVE
POST GRAD
BACHELOR
CARPOOL NONE
There's an above average rate of no education in our community.
HIGH SCHOOL
SOME COLLEGE
43
Plan & Perspective
E xa
ms
Office/Kitchen
sks k De
Exa ms
Kios
Storage Lobby F
F
Test Result Room Shower, Storage
44
r
ente
elp C
lH Socia
sp Re ira
Lobby
ry to am Ex Cafe F
F
Second Floor
16’
48’
80’
144’
45 Birdeye View
Interior Render Exam Lobby Section
46
F
F
47
Urban Food Garden 48
Junior Studio (2020)
49
Design Figure Ground
Champaign Downtown
N
First Floor First Floor Plan Plan
Entrance Egress
Exhibition
Seed Exchange
Toilet Elevator
Toilet
Elevator Egress
Mechanic
Garbage Room Storage
Service Dock
50
Classroom
Inspiration
E S
E
S
W
W
W
E
N
S
N
N
Cardinal Points - Program Planned with priority.
South Elevation
W/E Section
W/E Section
51
Stair Case Designs 3D Modeling & Form Study
Stair Case Interior
52
South Side Exterior
Interior
53
Thank you
54