Work Sample-Spring 2023 3rd Year Studio

Page 1

1

2

3

4

5

E

3801 W Temple Ave Pomona, CA 91768 jpajer@cpp.edu (916) 693-9027

Consultant: Anton Schneider 3801 W Temple Ave, Pomona, CA 91768 abschneider@cpp.edu (916) 693-9027

REVISIONS

VINCINITY MAP: PROJECT INFORMATION:

SHEET INDEX:

PROJECT ADDRESS

610 NORTH SANTIAGO STREET, SANTA ANA, CA 92701

INFORMATION

4-STORY 65-UNIT TYPE MIXED-USE/ MULTIFAMILY RESIDENTIAL OVER 1-STORY TYPE 1A RETAIL

G-101 A-001 A-100 A-101 A-105 A-110 A-111 A-112 A-200 A-300 A-310 A-400 A-410 A-420 A-501 A-503 A-600 MECHANICAL M-100 ELECTRICAL E-100 PLUMBING P-100

B

COVER SHEET CODE ANALYSIS SITE PLAN SITE SECTION OCCUPANCY/EGRESS PLANS GROUND FLOOR PLAN PODIUM FLOOR PLAN SUBSEQUENT FLOOR PLAN BUILDING ELEVATIONS BUILDING SECTIONS WALL SECTION UNIT PLAN INTERIOR VISUALIZATIONS ENLARGED STAIR PLAN / SECTION WALL AND FLOOR ASSEMBLIES DETAILS WINDOW SCHEDULE MECHANICAL RCP AND DIAGRAM ELECTRICAL PLUMBING RCP AND DIAGRAM

620 N Santiago St, Santa Ana, CA 92701

BUILDING SUMMARY:

A

Date 3/24/2022 5/12/2022

620 N Santiago St, Santa Ana, CA 92701

C

ABREVIATION:

Description MIDTERM FINAL

MIXED-USE MULTI-FAMILY COMPLEX

D

Issued by J.P. J.P.

SANTA ANA HOUSING

No. 01 02

GROSS SITE AREA

68,933 SF

STORIES ABOVE GRADE

5 STORIES

STORIES ABOVE GRADE

0 STORIES

ZONING GENERAL PLAN DESIGNATION

CR

MAXIMUM HEIGHT LIMIT

75'-0"

CONSTRUCTION TYPE

VA OVER 1A (5 LEVELS ABOVE GRD

PROPOSED USE

MIXED-USE RESIDENTIAL/PARKING/ RETAIL

FULLY SPRINKLERED BUILDING WITH NFPA 13 SPRINKLER SYSTEM (SECTION 903.2.11.3)

TITLE SHEET

PROJECT NUMBER

M4 12 MAY 2023

DATE ISSUED BY

A.S.

CHECKED BY

A.S.

G-101

FIRE ALARM AND DETECTION SYSYEM (SECTION 907.2.2) Scale

AS INDICATED


APPLICABLE CODE:

CALIFORNIA BUILDING CODE (CBC) 2022 CALIFORNIA PLUMBING CODE (CPC) 2022 CALIFORNIA MECHANICAL CODE (CMC) 2022 CALIFORNIA ELECTRICAL CODE (CEC) 2022 CALIFORNIA ENERGY CODE 2022 CALIFORNIA GREEN STANDARDS STANDARDS CODE 2022 CALIFORNIA RESIDENTIAL CODE (CRC) 2022 AMERICANS WITH DISABILITIES ACT (ADA) NATIONAL FIRE PROTECTION ASSOCIATION STANDARD (NFPA 13 AND 17) LOS ANGELES MUNICIPAL CODE SANTA ANA MUNICIPAL CODE

D CALIFORNIA BUILDING CODE 2022 SECTION 309 MERCANTILE GROUP M

MERCANTILE GROUP M OCCUPANCY INCLUDES, AMONG OTHERS, THE USE OF A BUILDING OR STRUCTURE OR A PORTION THEREOF FOR THE DISPLAY AND SALE OF MERCHANDISE, AND INVOLVES STOCKS OF GOODS, WARES OR MERCHANDISE INCIDENTAL TO SUCH PURPOSES AND WHERE THE PUBLIC HAS ACCESS. MERCANTILE OCCUPANCIES SHALL INCLUDE, BUT NOT BE LIMITED TO, THE FOLLOWING:

C

DEPARTMENT STORES DRUG STORES MARKETS GREENHOUSES FOR DISPLAY AND SALE OF PLANTS THAT PROVIDE PUBLIC ACCESS. MOTOR FUEL-DISPENSING FACILITIES RETAIL OR WHOLESALE STORES SALES ROOMS 310.1 RESIDENTIAL GROUP R RESIDENTIAL GROUP R INCLUDES, AMONG OTHERS, THE USE OF A BUILDING OR STRUCTURE, OR A PORTION THEREOF, FOR SLEEPING PURPOSES WHEN NOT CLASSIFIED AS AN INSTITUTIONAL GROUP I OR WHEN NOT REGULATED BY THE CALIFORNIA RESIDENTIAL CODE. GROUP R OCCUPANCIES NOT CONSTRUCTED IN ACCORDANCE WITH THE CALIFORNIA RESIDENTIAL CODE AS PERMITTED BY SECTIONS 310.4.1 AND 310.4.2 SHALL COMPLY WITH SECTION 420. 310.3 RESIDENTIAL GROUP R-2

B

RESIDENTIAL GROUP R-2 OCCUPANCIES CONTAINING SLEEPING UNITS OR MORE THAN TWO DWELLING UNITS WHERE THE OCCUPANTS ARE PRIMARILY PERMANENT IN NATURE, INCLUDING: APARTMENT HOUSES LARGE FAMILY CHILD CARE SMALL FAMILY CHILD CARE CONGREGATE RESIDENCES (NONTRANSIENT) WITH MORE THAN 16 OCCUPANTS BOARDING HOUSES (NONTRANSIENT) CONVENTS, DORMITORIES FRATERNITIES AND SORORITIES MONASTERIES HOTELS (NONTRANSIENT) LIVE/WORK UNITS MOTELS (NONTRANSIENT) VACATION TIMESHARE PROPERTIES [HCD 1] EFFICIENCY DWELLING UNITS (TRANSIENT) 703A.5.1 GENERAL MATERIAL AND MATERIAL ASSEMBLIES TESTED IN ACCORDANCE WITH THE REQUIREMENTS OF SECTION 703A SHALL MAINTAIN THEIR FIRE TEST PERFORMANCE UNDER CONDITIONS OF USE, WHEN INSTALLED IN ACCORDANCE WITH THE MANUFACTURERS INSTRUCTIONS. 703A.5.3 SURFACE TREATMENT PROTECTION

A

THE USE OF PAINTS, COATINGS, STAINS OR OTHER SURFACE TREATMENTS ARE NOT AN APPROVED METHOD OF PROTECTION AS REQUIRED IN THIS CHAPTER.

4

5

703A.7 STANDARDS OF QUALITY

1202.3 UNVENTED ATTIC AND UNVENTED ENCLOSED RAFTER ASSEMBLIES

THE STATE FIRE MARSHAL STANDARDS FOR EXTERIOR WILDFIRE EXPOSURE PROTECTION LISTED BELOW AND AS REFERENCED IN THIS CHAPTER ARE LOCATED IN THE CALIFORNIA REFERENCED STANDARDS CODE, PART 12 AND CHAPTER 35 OF THIS CODE. SFM STANDARD 12-7A-1, EXTERIOR WALL SIDING AND SHEATHING. A FIRE RESISTANCE TEST STANDARD CONSISTING OF A 150 KW INTENSITY DIRECT FLAME EXPOSURE FOR A 10-MINUTE DURATION. SFM STANDARD 12-7A-2, EXTERIOR WINDOWS. A FIRE RESISTANCE TEST STANDARD CONSISTING OF A 150 KW INTENSITY DIRECT FLAME EXPOSURE FOR AN 8-MINUTE DURATION. SFM STANDARD 12-7A-3, HORIZONTAL PROJECTION UNDERSIDE A FIRE RESISTANCE TEST STANDARD CONSISTING OF A 300 KW INTENSITY DIRECT FLAME EXPOSURE FOR A 10-MINUTE DURATION. SFM STANDARD 12-7A-4, DECKING. A TWO-PART TEST CONSISTING OF A HEAT RELEASE RATE (PART A) DECK ASSEMBLY COMBUSTION TEST WITH AN UNDER DECK EXPOSURE OF 80 KW INTENSITY DIRECT FLAME FOR A 3-MINUTE DURATION, AND A (PART B) SUSTAINED DECK ASSEMBLY COMBUSTION TEST CONSISTING OF A DECK UPPER SURFACE BURNING EMBER EXPOSURE WITH A 12 MPH WIND FOR 40 MINUTES USING A 2.2LB (1KG) BURNING "CLASS A" SIZE 12" X 12" X 2.25" (300 MM X 300 MM X 57 MM) ROOF TEST BRAND. SFM STANDARD 12-7A-4A, DECKING ALTERNATE METHOD A. A HEAT RELEASE RATE DECK ASSEMBLY COMBUSTION TEST WITH AN UNDER DECK EXPOSURE OF 80 KW INTENSITY DIRECT FLAME FOR A 3-MINUTE DURATION. ASTM D2898 STANDARD PRACTICE FOR ACCELERATED WEATHERING OF FIRE-RETARDANT-TREATED WOOD FOR FIRE TESTING. ASTM D3909/D3909M STANDARD SPECIFICATION FOR ASPHALT ROLL ROOFING (GLASS FELT) SURFACED WITH MINERAL GRANULES. ASTM E84 STANDARD TEST METHOD FOR SURFACE BURNING CHARACTERISTICS OF BUILDING MATERIALS. ASTM E119 STANDARD TEST METHODS FOR FIRE TESTS OF BUILDING CONSTRUCTION AND MATERIALS. ASTM E2632/E2632M STANDARD TEST METHOD FOR EVALUATING THE UNDER-DECK FIRE TEST RESPONSE OF DECK MATERIALS. ASTM E2707 STANDARD TEST METHOD FOR DETERMINING FIRE PENETRATION OF EXTERIOR WALL ASSEMBLIES USING A DIRECT FLAME IMPINGEMENT EXPOSURE. ASTM E2726/E2726M STANDARD TEST METHOD FOR EVALUATING THE FIRE TEST RESPONSE OF DECK STRUCTURES TO BURNING BRANDS. ASTM E2768 STANDARD TEST METHOD FOR EXTENDED DURATION SURFACE BURNING CHARACTERISTICS OF BUILDING MATERIALS (30-MINUTE TUNNEL TEST). ASTM E2886/E2886M STANDARD TEST METHOD FOR EVALUATING THE ABILITY OF EXTERIOR VENTS TO RESIST THE ENTRY OF EMBERS AND DIRECT FLAME IMPINGEMENT. ASTM E2957 STANDARD TEST METHOD FOR RESISTANCE TO WILDFIRE PENETRATION OF EAVES, SOFFITS AND OTHER PROJECTIONS. NFPA 257 STANDARD ON FIRE TEST FOR WINDOW AND GLASS BLOCK ASSEMBLIES. UL 263 STANDARD FOR FIRE TESTS OF BUILDING CONSTRUCTION AND MATERIALS. UL 723 STANDARD FOR TEST FOR SURFACE BURNING CHARACTERISTICS OF BUILDING MATERIALS.

IN CLIMATE ZONES 5, 6, 7 AND 8, ANY AIR-IMPERMEABLE INSULATION SHALL BE A CLASS II VAPOR RETARDER OR SHALL HAVE A CLASS II VAPOR RETARDER COATING OR COVERING IN DIRECT CONTACT WITH THE UNDERSIDE OF THE INSULATION.WHERE AIR-PERMEABLE INSULATION IS PROVIDED INSIDE THE BUILDING THERMAL ENVELOPE, IT SHALL BE INSTALLED IN ACCORDANCE WITH ITEM 5.1.1. IN ADDITION TO THE AIR-PERMEABLE INSULATION INSTALLED DIRECTLY BELOW THE STRUCTURAL SHEATHING, RIGID BOARD OR SHEET INSULATION SHALL BE INSTALLED DIRECTLY ABOVE THE STRUCTURAL ROOF SHEATHING IN ACCORDANCE WITH THE R-VALUES IN TABLE 1202.3 FOR CONDENSATION CONTROL.WHERE BOTH AIR-IMPERMEABLE AND AIR-PERMEABLE INSULATION ARE PROVIDED, THE AIR-IMPERMEABLE INSULATION SHALL BE APPLIED IN DIRECT CONTACT WITH THE UNDERSIDE OF THE STRUCTURAL ROOF SHEATHING AND SHALL BE IN ACCORDANCE WITH THE R-VALUES IN TABLE 1202.3 FOR CONDENSATION CONTROL. THE AIR-PERMEABLE INSULATION SHALL BE INSTALLED DIRECTLY UNDER THE AIR-IMPERMEABLE INSULATION.ALTERNATIVELY, SUFFICIENT RIGID BOARD OR SHEET INSULATION SHALL BE INSTALLED DIRECTLY ABOVE THE STRUCTURAL ROOF SHEATHING TO MAINTAIN THE MONTHLY AVERAGE TEMPERATURE OF THE UNDERSIDE OF THE STRUCTURAL ROOF SHEATHING ABOVE 45°F (7°C). FOR CALCULATION PURPOSES, AN INTERIOR AIR TEMPERATURE OF 68°F (20°C) IS ASSUMED AND THE EXTERIOR AIR TEMPERATURE IS ASSUMEDTO BE THE MONTHLY AVERAGE OUTSIDE AIR TEMPERATURE OF THE THREE COLDEST MONTHS.

704A.4 ALTERNATIVE METHODS FOR DETERMINING IGNITION-RESISTANT MATERIAL ANY ONE OF THE FOLLOWING SHALL BE ACCEPTED AS MEETING THE DEFINITION OF IGNITION-RESISTANT MATERIAL: NONCOMBUSTIBLE MATERIAL. MATERIAL THAT COMPLIES WITH THE DEFINITION FOR NONCOMBUSTIBLE MATERIALS IN SECTION 202. FIRE-RETARDANT-TREATED WOOD. FIRE-RETARDANT-TREATED WOOD IDENTIFIED FOR EXTERIOR USE THAT COMPLIES WITH THE REQUIREMENTS OF SECTION 2303.2. FIRE-RETARDANT-TREATED WOOD SHINGLES AND SHAKES. FIRE-RETARDANT-TREATED WOOD SHINGLES AND SHAKES, AS DEFINED IN SECTION 1505.6 AND LISTED BY STATE FIRE MARSHAL FOR USE AS "CLASS B" ROOF COVERING, SHALL BE ACCEPTED AS AN IGNITION-RESISTANT WALL COVERING MATERIAL WHEN INSTALLED OVER SOLID SHEATHING. 705A.2 ROOF COVERINGS WHERE THE ROOFING PROFILE HAS AN AIRSPACE UNDER THE ROOF COVERING, INSTALLED OVER A COMBUSTIBLE DECK, A 72 LB. (32.7 KG) CAP SHEET COMPLYING WITH ASTM D3909 STANDARD SPECIFICATION FOR "ASPHALT ROLLED ROOFING (GLASS FELT) SURFACED WITH MINERAL GRANULES," SHALL BE INSTALLED OVER THE ROOF DECK. BIRD STOPS SHALL BE USED AT THE EAVES WHEN THE PROFILE FITS, TO PREVENT DEBRIS AT THE EAVE. HIP AND RIDGE CAPS SHALL BE MUDDED IN TO PREVENT INTRUSION OF FIRE OR EMBERS. EXCEPTION: CAP SHEET IS NOT REQUIRED WHEN NO LESS THAN 1" OF MINERAL WOOL BOARD OR OTHER NONCOMBUSTIBLE MATERIAL IS LOCATED BETWEEN THE ROOFING MATERIAL AND WOOD FRAMING OR DECK. ALTERNATELY, A CLASS A FIRE RATED ROOF UNDERLAYMENT, TESTED IN ACCORDANCE WITH ASTM E108, SHALL BE PERMITTED TO BE USED. IF THE SHEATHING CONSISTS OF EXTERIOR FIRE-RETARDANT-TREATED WOOD, THE UNDERLAYMENT SHALL NOT BE REQUIRED TO COMPLY WITH A CLASS A CLASSIFICATION. BIRD STOPS SHALL BE USED AT THE EAVES WHEN THE PROFILE FITS, TO PREVENT DEBRIS AT THE EAVE. HIP AND RIDGE CAPS SHALL BE MUDDED IN TO PREVENT INTRUSION OF FIRE OR EMBERS. 705A.4 ROOF GUTTERS ROOF GUTTERS SHALL BE PROVIDED WITH THE MEANS TO PREVENT THE ACCUMULATION OF LEAVES AND DEBRIS IN THE GUTTER. 1202.2.1 VENTILATED ATTICS AND RAFTER SPACES ENCLOSED ATTICS AND ENCLOSED RAFTER SPACES FORMED WHERE CEILINGS ARE APPLIED DIRECTLY TO THE UNDERSIDE OF ROOF FRAMING MEMBERS SHALL HAVE CROSS VENTILATION FOR EACH SEPARATE SPACE BY VENTILATION OPENINGS PROTECTED AGAINST THE ENTRANCE OF RAIN AND SNOW. BLOCKING AND BRIDGING SHALL BE ARRANGED SO AS NOT TO INTERFERE WITH THE MOVEMENT OF AIR. AN AIRSPACE OF NOT LESS THAN 1 INCH (25 MM) SHALL BE PROVIDED BETWEEN THE INSULATION AND THE ROOF SHEATHING. THE NET FREE VENTILATING AREA SHALL BE NOT LESS THAN 1/150 OF THE AREA OF THE SPACE VENTILATED. VENTILATORS SHALL BE INSTALLED IN ACCORDANCE WITH MANUFACTURER'S INSTALLATION INSTRUCTIONS. EXCEPTION: THE NET FREE CROSS-VENTILATION AREA SHALL BE PERMITTED TO BE REDUCED TO 1/300 PROVIDED BOTH OF THE FOLLOWING CONDITIONS ARE MET: IN CLIMATE ZONES 6, 7 AND 8, A CLASS I OR II VAPOR RETARDER IS INSTALLED ON THE WARM-IN-WINTER SIDE OF THE CEILING. AT LEAST 40 PERCENT AND NOT MORE THAN 50 PERCENT OF THE REQUIRED VENTING AREA IS PROVIDED BY VENTILATORS LOCATED IN THE UPPER PORTION OF THE ATTIC OR RAFTER SPACE. UPPER VENTILATORS SHALL BE LOCATED NOT MORE THAN 3 FEET (914 MM) BELOW THE RIDGE OR HIGHEST POINT OF THE SPACE, MEASURED VERTICALLY, WITH THE BALANCE OF THE VENTILATION PROVIDED BY EAVE OR CORNICE VENTS. WHERE THE LOCATION OF WALL OR ROOF FRAMING MEMBERS CONFLICTS WITH THE INSTALLATION OF UPPER VENTILATORS, INSTALLATION MORE THAN 3 FEET (914 MM) BELOW THE RIDGE OR HIGHEST POINT OF THE SPACE SHALL BE PERMITTED.

1202.5.2.1 BATHROOMS

3801 W Temple Ave Pomona, CA 91768 jpajer@cpp.edu (916) 693-9027

Consultant: Anton Schneider 3801 W Temple Ave, Pomona, CA 91768 abschneider@cpp.edu (916) 693-9027

REVISIONS No. 01 02

Issued by J.P. J.P.

Description MIDTERM FINAL

Date 3/24/2022 5/12/2022

ROOMS CONTAINING BATHTUBS, SHOWERS, SPAS AND SIMILAR BATHING FIXTURES SHALL BE MECHANICALLY VENTILATED IN ACCORDANCE WITH THE CALIFORNIA MECHANICAL CODE. THE MINIMUM EXHAUST RATE SHALL NOT BE LESS THAN THAT ESTABLISHED BY TABLE 403.7 "MINIMUM EXHAUST RATES." SEE CALIFORNIA MECHANICAL CODE, CHAPTER 5, FOR ADDITIONAL PROVISIONS RELATED TO ENVIRONMENTAL AIR DUCTS. [HCD 1] IN ADDITION TO THE REQUIREMENTS IN THIS SECTION AND IN THE CALIFORNIA MECHANICAL CODE, BATHROOMS IN GROUP R OCCUPANCIES SHALL BE MECHANICALLY VENTILATED IN ACCORDANCE WITH THE CALIFORNIA GREEN BUILDING STANDARDS CODE (CALGREEN), CHAPTER 4, DIVISION 4.5. 1204.2.1 ADJOINING SPACES FOR THE PURPOSE OF NATURAL LIGHTING, ANY ROOM IS PERMITTED TO BE CONSIDERED AS A PORTION OF AN ADJOINING ROOM WHERE ONE-HALF OF THE AREA OF THE COMMON WALL IS OPEN AND UNOBSTRUCTED AND PROVIDES AN OPENING OF NOT LESS THAN ONE-TENTH OF THE FLOOR AREA OF THE INTERIOR ROOM OR 25 SQUARE FEET (2.32 M2), WHICHEVER IS GREATER. EXCEPTION: OPENINGS REQUIRED FOR NATURAL LIGHT SHALL BE PERMITTED TO OPEN INTO A SUNROOM WITH THERMAL ISOLATION OR A PATIO COVER WHERE THE COMMON WALL PROVIDES A GLAZED AREA OF NOT LESS THAN ONE-TENTH OF THE FLOOR AREA OF THE INTERIOR ROOM OR 20 SQUARE FEET (1.86 M2), WHICHEVER IS GREATER. 1204.2.2 EXTERIOR OPENINGS EXTERIOR OPENINGS REQUIRED BY SECTION 1204.2 FOR NATURAL LIGHT SHALL OPEN DIRECTLY ONTO A PUBLIC WAY, YARD OR COURT, AS SET FORTH IN SECTION 1205. EXCEPTIONS: REQUIRED EXTERIOR OPENINGS ARE PERMITTED TO OPEN INTO A ROOFED PORCH WHERE THE PORCH MEETS ALL OF THE FOLLOWING CRITERIA: ABUTS A PUBLIC WAY, YARD OR COURT. HAS A CEILING HEIGHT OF NOT LESS THAN 7 FEET (2134 MM). HAS A LONGER SIDE AT LEAST 65 PERCENT OPEN AND UNOBSTRUCTED. SKYLIGHTS ARE NOT REQUIRED TO OPEN DIRECTLY ONTO A PUBLIC WAY, YARD OR COURT. 1204.3 ARTIFICIAL LIGHT ARTIFICIAL LIGHT SHALL BE PROVIDED THAT IS ADEQUATE TO PROVIDE AN AVERAGE ILLUMINATION OF 10 FOOTCANDLES (107 LUX) OVER THE AREA OF THE ROOM AT A HEIGHT OF 30 INCHES (762 MM) ABOVE THE FLOOR LEVEL. 505.2 MEZZANINES

620 N Santiago St, Santa Ana, CA 92701

E

3

MIXED-USE MULTI-FAMILY COMPLEX

CODE ANALYSIS:

2

SANTA ANA HOUSING

1

A MEZZANINE OR MEZZANINES IN COMPLIANCE WITH SECTION 505.2 SHALL BE CONSIDERED A PORTION OF THE STORY BELOW. SUCH MEZZANINES SHALL NOT CONTRIBUTE TO EITHER THE BUILDING AREA OR NUMBER OF STORIES AS REGULATED BY SECTION 503.1. THE AREA OF THE MEZZANINE SHALL BE INCLUDED IN DETERMINING THE FIRE AREA. THE CLEAR HEIGHT ABOVE AND BELOW THE MEZZANINE FLOOR CONSTRUCTION SHALL BE NOT LESS THAN 7 FEET (2134 MM). 1402.2 WEATHER PROTECTION

620 N Santiago St, Santa Ana, CA 92701

A WEATHER-RESISTANT EXTERIOR WALL ENVELOPE SHALL NOT BE REQUIRED OVER CONCRETE OR MASONRY WALLS DESIGNED IN ACCORDANCE WITH CHAPTERS 19 AND 21, RESPECTIVELY. COMPLIANCE WITH THE REQUIREMENTS FOR A MEANS OF DRAINAGE, AND THE REQUIREMENTS OF SECTIONS 1403.2 AND 1404.4, SHALL NOT BE REQUIRED FOR AN EXTERIOR WALL ENVELOPE THAT HAS BEEN DEMONSTRATED THROUGH TESTING TO RESIST WIND-DRIVEN RAIN, INCLUDING JOINTS, PENETRATIONS AND INTERSECTIONS WITH DISSIMILAR MATERIALS, IN ACCORDANCE WITH ASTM E331 UNDER THE FOLLOWING CONDITIONS: THE EXTERIOR WALL ENVELOPE DESIGN SHALL BE CONSIDERED TO RESIST WIND-DRIVEN RAIN WHERE THE RESULTS OF TESTING INDICATE THAT WATER DID NOT PENETRATE CONTROL JOINTS IN THE EXTERIOR WALL ENVELOPE, JOINTS AT THE PERIMETER OF OPENINGS OR INTERSECTIONS OF TERMINATIONS WITH DISSIMILAR MATERIALS. EXTERIOR WALL ENVELOPE TEST ASSEMBLIES SHALL INCLUDE NOT FEWER THAN ONE OPENING, ONE CONTROL JOINT, ONE WALL/EAVE INTERFACE AND ONE WALL SILL. TESTED OPENINGS AND PENETRATIONS SHALL BE REPRESENTATIVE OF THE INTENDED END-USE CONFIGURATION. EXTERIOR WALL ENVELOPE TEST ASSEMBLIES SHALL BE NOT LESS THAN 4 FEET BY 8 FEET (1219 MM BY 2438 MM) IN SIZE. EXTERIOR WALL ENVELOPE ASSEMBLIES SHALL BE TESTED AT A MINIMUM DIFFERENTIAL PRESSURE OF 6.24 POUNDS PER SQUARE FOOT (0.297 KN/M2). EXTERIOR WALL ENVELOPE ASSEMBLIES SHALL BE SUBJECTED TO A MINIMUM TEST EXPOSURE DURATION OF 2 HOURS.

CODE ANALYSIS

PROJECT NUMBER

M4 12 MAY 2023

DATE ISSUED BY

A.S.

CHECKED BY

A.S.

A-001 Scale

AS INDICATED


1

2

3

4

5

E

3801 W Temple Ave Pomona, CA 91768 jpajer@cpp.edu (916) 693-9027

Consultant: Anton Schneider 3801 W Temple Ave, Pomona, CA 91768 abschneider@cpp.edu (916) 693-9027

REVISIONS

C

Description MIDTERM FINAL

Date 3/24/2022 5/12/2022

620 N Santiago St, Santa Ana, CA 92701

SANTA ANA HOUSING

D

Issued by J.P. J.P.

MIXED-USE MULTI-FAMILY COMPLEX

No. 01 02

B

620 N Santiago St, Santa Ana, CA 92701

SITE PLAN

A

PROJECT NUMBER

M4 12 MAY 2023

DATE ISSUED BY

A.S.

CHECKED BY

A.S.

A-100 A1

Scale

AS INDICATED


1

2

3

4

5

E

3801 W Temple Ave Pomona, CA 91768 jpajer@cpp.edu (916) 693-9027

Consultant: Anton Schneider 3801 W Temple Ave, Pomona, CA 91768 abschneider@cpp.edu (916) 693-9027

REVISIONS

C

Description MIDTERM FINAL

Date 3/24/2022 5/12/2022

620 N Santiago St, Santa Ana, CA 92701

SANTA ANA HOUSING

D

Issued by J.P. J.P.

MIXED-USE MULTI-FAMILY COMPLEX

No. 01 02

B

620 N Santiago St, Santa Ana, CA 92701

SITE SECTION

A A1

SHARED ELEVATION 1/16" = 1'0"

PROJECT NUMBER

M4 12 MAY 2023

DATE ISSUED BY

A.S.

CHECKED BY

A.S.

A-101 Scale

AS INDICATED


1

2

3

4

5

E

3801 W Temple Ave Pomona, CA 91768 jpajer@cpp.edu (916) 693-9027 UP Consultant: Anton Schneider 3801 W Temple Ave, Pomona, CA 91768 abschneider@cpp.edu (916) 693-9027

REVISIONS

C GYM

Description MIDTERM FINAL

Date 3/24/2022 5/12/2022

620 N Santiago St, Santa Ana, CA 92701

SANTA ANA HOUSING

D

Issued by J.P. J.P.

MIXED-USE MULTI-FAMILY COMPLEX

No. 01 02

B

620 N Santiago St, Santa Ana, CA 92701

EGRESS AND OCCUPANCY PLANS

KEY EGRESS CORE

CIRCULATION

A

PROJECT NUMBER

12 MAY 2023

DATE

0'1'

A2

EGRESS PLAN 1/16" = 1'-0"

M4

ISSUED BY

A.S.

CHECKED BY

A.S.

A-105

5'

Scale

AS INDICATED


1

2

3

4

5

P D1

A 14'

A-200

C - 0"

14'

B 14' -

- 0"

O

D 14'

0"

- 0"

'-

E - 0"

F

'-

14' -

0"

M

15' - 0"

G '-

14

L

07

15'

- 0"

'-

RETAIL

LIVE-WORK

101

103

2520 SF

350 SF

14

N 14'

06

E

'-

14

14

K 4'

LIVE-WORK

J

104

08

1

14

0"

0"

0"

0"

0"

CIVIC INDOOR

0"

111

UP

350 SF

2380 SF

3801 W Temple Ave Pomona, CA 91768 jpajer@cpp.edu (916) 693-9027

LIVE-WORK 115 13

15'

- 0"

I

'

350 SF

" -6

LIVE-WORK

UP

09

14

H - 0"

114

"

0 '-

349 SF

15'

RETAIL LIVE-WORK

102 1051 SF

112

10

105

LIVE-WORK

10'

- 0"

1185 SF

REVISIONS

113 352 SF

CIVIC OUTDOOR

No. 01 02

UP

Issued by J.P. J.P.

Description MIDTERM FINAL

Date 3/24/2022 5/12/2022

- 0"

0"

01

A1

'10

D

351 SF

RETAIL

11

Consultant: Anton Schneider 3801 W Temple Ave, Pomona, CA 91768 abschneider@cpp.edu (916) 693-9027

15'

A-300

'-

15

02

0"

12

RETAIL 1135 SF

"

15'

-0

- 0"

106

' 15

03 Q

04 S

05 0"

14

T 14'

- 0"

U

15'

- 0"

14'

RETAIL

V 14' -

116

15

0"

W

2863 SF

14' -

0"

X 0"

Y

- 0"

14' -

D1

14'

20'

C

- 0"

A-200

16

- 0"

D1

Z

A-200 14' -

ELECTRIC

0"

AA

128 - 0"

14' -

RETAIL

324 SF

10'

117 805 SF

17

- 0"

AC 14'

- 0" 15'

AB 14'

ADA TRASH

- 0"

AD

RETAIL

127

18

0"

340 SF

118

ADA

802 SF

15'

- 0"

UP

19

BIKE PARKING 130 10' - 0"

Not Enclosed

ADA

20

620 N Santiago St, Santa Ana, CA 92701

14' -

MIXED-USE MULTI-FAMILY COMPLEX

0"

15'

- 0"

14' -

0"

R

'-

- 0"

SANTA ANA HOUSING

14'

10

13

RETAIL

21

ADA

9' -

B

6"

119 628 SF

UP

- 0"

UP

15'

LOADING DOCK 120

22

413 SF

15' -

0"

620 N Santiago St, Santa Ana, CA 92701

23

0"

UP

15' -

RETAIL

24

LIVE-WORK

126

125

2734 SF

350 SF

GROUND FLOOR PLAN

LIVE-WORK 124

0"

350 SF

15' -

LIVE-WORK 123

MECHANICAL

350 SF

25

LIVE-WORK 122

A

LOBBY

121

130

394 SF

1094 SF

350 SF

15'

- 0"

PROJECT NUMBER

12 MAY 2023

DATE

26

A

A-300

GROUND FLOOR 1 1/16" = 1'-0"

ISSUED BY

A.S.

CHECKED BY

A.S.

A-110

D1 A-200

0'1'

M4

5'

Scale

AS INDICATED


1

2

3

4

5

P

C1 A-200

A

06

14' 10'

07

'

C 14'

B 14'

D '

14'

14

N

E 14'

'

F

M

14'

15'

E

14

O

G

14

'

08

14

L 14

15'

K

'

'

14

09

J 10'

3801 W Temple Ave Pomona, CA 91768 jpajer@cpp.edu (916) 693-9027

10

'

14

I '

H

UP

20'

14

Consultant: Anton Schneider 3801 W Temple Ave, Pomona, CA 91768 abschneider@cpp.edu (916) 693-9027

11

15'

REVISIONS '

A1 A-300

No. 01 02

10

D

01

12

Description MIDTERM FINAL

Date 3/24/2022 5/12/2022

15'

'

15

02

Issued by J.P. J.P.

13

R

05 S 14'

15

T 14'

U 14'

V

20'

14'

W 14'

16

14'

Y

C1 A-200

10'

C

X C1 14'

17

A-200

Z 14'

AA

15'

14'

14'

GYM

18

AB AC AD

15'

14'

10'

19

10'

20

21

22

15'

B

620 N Santiago St, Santa Ana, CA 92701

15'

14'

MIXED-USE MULTI-FAMILY COMPLEX

14

'

04 14'

10

Q

SANTA ANA HOUSING

15'

' 15

03

23

15'

620 N Santiago St, Santa Ana, CA 92701

15'

24

PODIUM FLOOR PLAN

15'

25

26

A

PROJECT NUMBER

12 MAY 2023

DATE

0'1'

C1

2ND FLOOR 1/16" = 1'-0"

A-300

A2

A1 A-200

M4

ISSUED BY

A.S.

CHECKED BY

A.S.

A-111

5'

Scale

AS INDICATED


1

2

3

4

5

E

3801 W Temple Ave Pomona, CA 91768 jpajer@cpp.edu (916) 693-9027

O

C

14'

D

14'

N

E

14'

' 14

M

F

14'

G

15'

L

K

09

' 14

' 14

10'

14'

D

'

14'

O

E

14'

14'

07

14

K

14

A1

14'

A-200

B

14'

' 14

C

14'

O

'

14'

N

E

14'

14

REVISIONS

'

F

M

14'

14

No. 01 02

'

G L

14

'

09

K

14

Issued by J.P. J.P.

Description MIDTERM FINAL

Date 3/24/2022 5/12/2022

'

14

'

'

14

'

D

08

' 14

P

'

14

J

'

J

14

I

14

I

'

' 14

H

14

' 10 15 ' 15

02

'

15

02

'

A-300

' 10

04

01

A1

' 15

A-300

' 15

03

01

A1

' 15

02

A1 A-300

M

UP

H

01

G

L

' 14

H

14

'

N

F

09

J

' 14

I

P

08

' 14

10

C

07

'

14

A

A-200

14'

15'

'

14

A1

B

15'

14'

14'

15'

10'

B

08

D

P

A-200

15'

07

A1

14'

15'

A A

06

Consultant: Anton Schneider 3801 W Temple Ave, Pomona, CA 91768 abschneider@cpp.edu (916) 693-9027

03

03

14'

Q 11

T

14'

12 U

14'

10'

14

15

V

14'

14'

R

14'

S

14'

W

14'

T

14'

Y

14'

Z

14'

U

14'

UP 14'

AA

14'

AB

14'

AC

14'

C1 A-200

Q 17

18

13 X

C1 A-200

V

14'

14'

C1 A-200

R

14'

S

14'

T

14'

U

14'

W

14'

19 X

14'

Y

14'

Z

14'

AA

14'

AB

AD

14'

AC

14'

V

14'

W

14'

X

14'

Y

14'

Z

14'

AA

14'

AB

AD

UP

14'

AC

14'

AD

UP

620 N Santiago St, Santa Ana, CA 92701

S

C1 A-200

15'

14'

C1 A-200

15'

R

15'

GYM

14'

15'

13

15'

C

Q

12

15'

C1 A-200

10'

11

MIXED-USE MULTI-FAMILY COMPLEX

SANTA ANA HOUSING

05

B A1

A1

4TH FLOOR 1/32" = 1'-0"

5'

A1 C1

B2

0'1'

A-200

B4 3

A-300

C1

3RD FLOOR 1/32" = 1'-0"

5'

A-300

C1

A-300

B1

0'1'

A-200

0'1'

5'

A-200

5TH FLOOR 1/32" = 1'-0"

620 N Santiago St, Santa Ana, CA 92701

UPPER FLOOR PLANS

A

PROJECT NUMBER

M4 12 MAY 2023

DATE ISSUED BY

A.S.

CHECKED BY

A.S.

A-112 Scale

AS INDICATED


1

2

3 A-200

10'

14'

07

P

B

'

14'

14

O C 14'

'

D

14

N 14'

15'

E

5

A1

A

06

4

E

'

14'

08

14

M

F 14'

G

14

'

15'

L

'

14

K

09 '

10'

14

UP

3801 W Temple Ave Pomona, CA 91768 jpajer@cpp.edu (916) 693-9027

J

10 '

14

I

'

14

H

Consultant: Anton Schneider 3801 W Temple Ave, Pomona, CA 91768 abschneider@cpp.edu (916) 693-9027

A1

'

02

A-300

No. 01 02

' 15

D

REVISIONS

10

01

Description MIDTERM FINAL

Date 3/24/2022 5/12/2022

' 15

03

Issued by J.P. J.P.

'

10

04

C1 A-200

Q

10'

C

12

C1 14'

A-200 R

15'

14'

GYM

13

S 14'

T 14'

U

V

15'

14'

14'

14

W

10'

14'

X 14'

15

Y 14'

Z 14'

AA 14'

AB 14'

B

620 N Santiago St, Santa Ana, CA 92701

11

MIXED-USE MULTI-FAMILY COMPLEX

SANTA ANA HOUSING

05

AC 14'

AD

620 N Santiago St, Santa Ana, CA 92701

3RD FLOOR PLAN A

PROJECT NUMBER

12 MAY 2023

DATE

A1 C1

3RD FLOOR 1/16" = 1'-0"

A-300

1

A-200

0'1'

M4

ISSUED BY

A.S.

CHECKED BY

A.S.

A-113

5'

Scale

AS INDICATED


1

2

3

4

5

A 14'

A1 A-200

B 14'

P C 14'

07

'

D

O E

15'

14'

E

14

'

14'

N

F

08

14'

14

'

G

14

M

'

15'

14

L 09

'

14

K

3801 W Temple Ave Pomona, CA 91768 jpajer@cpp.edu (916) 693-9027

4'

1

J '

14

I

Consultant: Anton Schneider 3801 W Temple Ave, Pomona, CA 91768 abschneider@cpp.edu (916) 693-9027

'

14

H

REVISIONS

A1

01

A-300

' 15

D

No. 01 02

Description MIDTERM FINAL

Date 3/24/2022 5/12/2022

' 15

02

Issued by J.P. J.P.

11

C1 14'

A-200 R

15'

14'

S 14'

T

12 14'

U

V

15'

14'

14'

13

W 14'

X 14'

UP

Y 14'

Z 14'

AA 14'

AB 14'

B

620 N Santiago St, Santa Ana, CA 92701

Q

C1 A-200

MIXED-USE MULTI-FAMILY COMPLEX

C

SANTA ANA HOUSING

03

AC 14'

AD

UP

620 N Santiago St, Santa Ana, CA 92701

4TH FLOOR PLAN A

PROJECT NUMBER

12 MAY 2023

DATE

A1 C1

4TH FLOOR 1/16" = 1'-0"

A-300

A2

A-200

0'1'

M4

ISSUED BY

A.S.

CHECKED BY

A.S.

A-114

5'

Scale

AS INDICATED


1

2

3 A-200 14'

P

B 14'

'

14

O

C 14'

D

'

14'

15'

E

5

A1

A

07

4

14

N E 14'

08

'

F

M 14'

G

14

'

14

15'

L

'

09

14

K

'

14

3801 W Temple Ave Pomona, CA 91768 jpajer@cpp.edu (916) 693-9027

J '

14

I

'

14

H

Consultant: Anton Schneider 3801 W Temple Ave, Pomona, CA 91768 abschneider@cpp.edu (916) 693-9027

REVISIONS

A1

01

' 15

D

No. 01 02

A-300

Description MIDTERM FINAL

Date 3/24/2022 5/12/2022

' 15

02

Issued by J.P. J.P.

17

C1 14'

A-200 R

15'

14'

S 14'

T

18 14'

U

V

15'

14'

14'

19

W 14'

X 14'

Y 14'

Z 14'

AA 14'

AB 14'

B

620 N Santiago St, Santa Ana, CA 92701

Q

C1 A-200

MIXED-USE MULTI-FAMILY COMPLEX

C

SANTA ANA HOUSING

03

AC 14'

AD

UP

620 N Santiago St, Santa Ana, CA 92701

5TH FLOOR PLAN A

PROJECT NUMBER

12 MAY 2023

DATE

A1 C1

A-300

5TH FLOOR A2 1/16" = 1'-0"

A-200

0'1'

M4

ISSUED BY

A.S.

CHECKED BY

A.S.

A-115

5'

Scale

AS INDICATED


1

2

3

4

5

E

3801 W Temple Ave Pomona, CA 91768 jpajer@cpp.edu (916) 693-9027 T.O. ROOF 70' - 0" Consultant: Anton Schneider 3801 W Temple Ave, Pomona, CA 91768 abschneider@cpp.edu (916) 693-9027

ROOF 58' - 0"

REVISIONS 5TH FLOOR 48' - 0"

D

No. 01 02

Issued by J.P. J.P.

Description MIDTERM FINAL

Date 3/24/2022 5/12/2022

4TH FLOOR 38' - 0"

3RD FLOOR 28' - 0"

2ND FLOOR

0' - 0"

C1

C

SOUTH ELEVATION 3/32" = 1' 0"

T.O. ROOF 70' - 0"

ROOF 58' - 0"

B

620 N Santiago St, Santa Ana, CA 92701

GROUND FLOOR

MIXED-USE MULTI-FAMILY COMPLEX

SANTA ANA HOUSING

18' - 0"

5TH FLOOR 48' - 0"

4TH FLOOR 38' - 0" 620 N Santiago St, Santa Ana, CA 92701 3RD FLOOR 28' - 0"

2ND FLOOR 18' - 0"

BUILDING ELEVATIONS GROUND FLOOR 0' - 0"

A

A1

EAST ELEVATION 3/32" = 1' 0"

PROJECT NUMBER

M4 12 MAY 2023

DATE ISSUED BY

A.S.

CHECKED BY

A.S.

A-200 Scale

AS INDICATED


1

2

3

4

5

E

3801 W Temple Ave Pomona, CA 91768 jpajer@cpp.edu (916) 693-9027

Consultant: Anton Schneider 3801 W Temple Ave, Pomona, CA 91768 abschneider@cpp.edu (916) 693-9027

T.O. ROOF 70' - 0"

ROOF 58' - 0"

D

5TH FLOOR 48' - 0"

REVISIONS No. 01 02

Issued by J.P. J.P.

Description MIDTERM FINAL

Date 3/24/2022 5/12/2022

4TH FLOOR 38' - 0"

3RD FLOOR 28' - 0"

2ND FLOOR

0' - 0"

C

C1

NORTH ELEVATION 3/32" = 1' 0"

T.O. ROOF 70' - 0"

ROOF 58' - 0"

B

620 N Santiago St, Santa Ana, CA 92701

GROUND FLOOR

MIXED-USE MULTI-FAMILY COMPLEX

SANTA ANA HOUSING

18' - 0"

5TH FLOOR 48' - 0"

4TH FLOOR 38' - 0" 620 N Santiago St, Santa Ana, CA 92701 3RD FLOOR 28' - 0"

2ND FLOOR 18' - 0"

BUILDING ELEVATIONS

GROUND FLOOR 0' - 0"

A

A1

WEST ELEVATION

PROJECT NUMBER

3/32" = 1' 0"

DATE

M4 12 MAY 2023

ISSUED BY

A.S.

CHECKED BY

A.S.

A-201 Scale

AS INDICATED


1

2

3

4

5

E

3801 W Temple Ave Pomona, CA 91768 jpajer@cpp.edu (916) 693-9027

Consultant: Anton Schneider 3801 W Temple Ave, Pomona, CA 91768 abschneider@cpp.edu (916) 693-9027

REVISIONS

VIEW FROM N SANTIAGO STREET

C3

VIEW FROM COURTYARD

C

Date 3/24/2022 5/12/2022

620 N Santiago St, Santa Ana, CA 92701

C1

Description MIDTERM FINAL

MIXED-USE MULTI-FAMILY COMPLEX

D

Issued by J.P. J.P.

SANTA ANA HOUSING

No. 01 02

B

620 N Santiago St, Santa Ana, CA 92701

EXTERIOR BUILDING VISUALIZATIONS A

A1

VIEW FROM PEDESTRIAN WALKWAY

A3

VIEW FROM COURTYARD PROJECT NUMBER DATE

M4 12 MAY 2023

ISSUED BY

A.S.

CHECKED BY

A.S.

A-210 Scale

AS INDICATED


1

2

3

4

5

E

3801 W Temple Ave Pomona, CA 91768 jpajer@cpp.edu (916) 693-9027

T.O. ROOF 70' - 0"

Consultant: Anton Schneider 3801 W Temple Ave, Pomona, CA 91768 abschneider@cpp.edu (916) 693-9027

ROOF 58' - 0"

5TH FLOOR

REVISIONS

48' - 0"

D

4TH FLOOR

No. 01 02

Issued by J.P. J.P.

Description MIDTERM FINAL

Date 3/24/2022 5/12/2022

38' - 0"

3RD FLOOR 28' - 0"

2ND FLOOR

0' - 0"

C1

C

ELEVATION A 3/32" = 1' 0"

T.O. ROOF 70' - 0"

ROOF 58' - 0"

620 N Santiago St, Santa Ana, CA 92701

SANTA ANA HOUSING

GROUND FLOOR

MIXED-USE MULTI-FAMILY COMPLEX

18' - 0"

5TH FLOOR 48' - 0"

B 4TH FLOOR 38' - 0"

3RD FLOOR 28' - 0"

620 N Santiago St, Santa Ana, CA 92701

2ND FLOOR 18' - 0"

BUILDING SECTIONS

GROUND FLOOR 0' - 0"

A

A1

ELEVATION B 3/32" = 1' 0"

PROJECT NUMBER

M4 12 MAY 2023

DATE ISSUED BY

A.S.

CHECKED BY

A.S.

A-300 Scale

AS INDICATED


1

2

3

4

5

T.O. ROOF 56' - 0"

E 2 A-503

RA-01

ROOF

3801 W Temple Ave Pomona, CA 91768 jpajer@cpp.edu (916) 693-9027

48' - 0"

Consultant: Anton Schneider 3801 W Temple Ave, Pomona, CA 91768 abschneider@cpp.edu (916) 693-9027

REVISIONS

1

No. 01 02

A-503

D

Issued by J.P. J.P.

Description MIDTERM FINAL

Date 3/24/2022 5/12/2022

A-502 3RD FLOOR FA-01

C

28' - 0"

2ND FLOOR 18' - 0"

620 N Santiago St, Santa Ana, CA 92701

3

MIXED-USE MULTI-FAMILY COMPLEX

38' - 0"

SANTA ANA HOUSING

FA-01

4TH FLOOR

B 1 A-502

620 N Santiago St, Santa Ana, CA 92701

WALL SECTION

A

PROJECT NUMBER

12 MAY 2023

DATE GROUND FLOOR 0' - 0"

A1

ELEVATION OF BUILDING CHUNK 3/8" = 1'0"

A3

WALL SECTION OF STACK 3/8" = 1'-0"

M4

ISSUED BY

A.S.

CHECKED BY

A.S.

A-310 Scale

AS INDICATED


1

B 14' - 0"

1

B

C

28' - 8" 14' - 0"

14' - 0"

LIVING ROOM

BEDROOM

102

101

130 SF

130 SF

2

BEDROOM

LIVING ROOM

101

103

102

191 SF

193 SF

191 SF

3

10' - 0"

1

1 1

1 15' - 0"

1

BATHROOM

103

104

219 SF

98 SF 0'

% CIRCULATION PER UNIT: 22.1%

1'

1

TWO BEDROOM AREA: 1059 SF

5'

1

B

C

1

28' - 8" 14' - 0"

KITCHEN

105

104

BATHROOM 106

78 SF

291 SF

99 SF 0'

1'

5'

B

14' - 0"

A

1

2

2

B

14' - 0"

14' - 0"

2

32' - 0"

LIVING/WORK

4

KITCHEN 102

201

260 SF

141 SF

15' - 0"

83 SF

BEDROOM

101

620 N Santiago St, Santa Ana, CA 92701 1 1

2 STUIO AREA: 395 SF

BED-LIVING

CLOSET

101

104

103

192 SF

36 SF

62 SF

1

POWDER ROOM

KITCHEN

103

102

202

49 SF

90 SF

81 SF

BATHROOM

BATHROOM

0'

2 1'

5'

2 LIVE - WORK AREA: 832 SF

% CIRCULATION PER UNIT: 22.1%

0'

1'

UNIT PLANS

5'

% CIRCULATION PER UNIT: 22.3%

4

STUDIO 1/8" = 1'-0"

Date 3/24/2022 5/12/2022

2 BEDROOM 1/8" = 1'-0"

A

1

BATHROOM

% CIRCULATION PER UNIT: 14.1%

2

Description MIDTERM FINAL

1

3

1 BEDROOM 1/8" = 1'-0"

Issued by J.P. J.P.

620 N Santiago St, Santa Ana, CA 92701

KITCHEN

No. 01 02

MIXED-USE MULTI-FAMILY COMPLEX

3

REVISIONS

32' - 0"

15' - 0"

3

3801 W Temple Ave Pomona, CA 91768 jpajer@cpp.edu (916) 693-9027

Consultant: Anton Schneider 3801 W Temple Ave, Pomona, CA 91768 abschneider@cpp.edu (916) 693-9027

1

19' - 4"

BEDROOM

SANTA ANA HOUSING

1

34' - 10"

10' - 0"

2

1

14' - 0"

1

4

ONE BEDROOM AREA: 666 SF

D

14' - 0"

3

1

C

42' - 8"

3

LIVE -WORK 1/8" = 1'-0"

PROJECT NUMBER

M4 12 MAY 2023

DATE ISSUED BY

A.S.

CHECKED BY

A.S.

A-400 Scale

AS INDICATED


1

2

3

4

5

E

9' - 8"

7' - 6"

3801 W Temple Ave Pomona, CA 91768 jpajer@cpp.edu (916) 693-9027

2' - 2" 2' - 0"

2' - 0"

Consultant: Anton Schneider 3801 W Temple Ave, Pomona, CA 91768 abschneider@cpp.edu (916) 693-9027

REVISIONS

D

B.0. SOFFIT 7' - 6"

B.0. SOFFIT 7' - 6"

F.F. 0' - 0"

F.F. 0' - 0"

No. 01 02

Issued by J.P. J.P.

Description MIDTERM FINAL

Date 3/24/2022 5/12/2022

C

C1

ENLARGED ADA BATHROOM PLAN 1/2" = 1'-0"

C3

Elevation A 1/2" = 1'-0"

B

C4

SANTA ANA HOUSING

2' - 7"

C

Elevation B 1/2" = 1'-0"

B.0. SOFFIT 7' - 6"

620 N Santiago St, Santa Ana, CA 92701

B

MIXED-USE MULTI-FAMILY COMPLEX

C-5 A-405

10' - 11"

D

3' - 11"

A

5' - 0"

ø 5' - 0"

B.0. SOFFIT 7' - 6"

LT-03

620 N Santiago St, Santa Ana, CA 92701

ADA BATHROOM DETAIL

LT-01

F.F. 0' - 0"

A

A1

ENLARGED ADA BATHROOM RCP 1/2" = 1'-0"

A3

Elevation C 1/2" = 1'-0"

F.F. 0' - 0"

A4

Elevation D 1/2" = 1'-0"

PROJECT NUMBER

M4 12 MAY 2023

DATE ISSUED BY

A.S.

CHECKED BY

A.S.

A-405 Scale

AS INDICATED


1

2

3

4

5

E

3801 W Temple Ave Pomona, CA 91768 jpajer@cpp.edu (916) 693-9027

Consultant: Anton Schneider 3801 W Temple Ave, Pomona, CA 91768 abschneider@cpp.edu (916) 693-9027

REVISIONS

C

Description MIDTERM FINAL

Date 3/24/2022 5/12/2022

620 N Santiago St, Santa Ana, CA 92701

SANTA ANA HOUSING

D

Issued by J.P. J.P.

MIXED-USE MULTI-FAMILY COMPLEX

No. 01 02

B

620 N Santiago St, Santa Ana, CA 92701

INTERIOR VISUALIZATION A

PROJECT NUMBER

A1

INTERIOR VISUALIZATION

M4 12 MAY 2023

DATE ISSUED BY

A.S.

CHECKED BY

A.S.

A-410 Scale

AS INDICATED


1

2

3

4

5

E

3801 W Temple Ave Pomona, CA 91768 jpajer@cpp.edu (916) 693-9027

Consultant: Anton Schneider 3801 W Temple Ave, Pomona, CA 91768 abschneider@cpp.edu (916) 693-9027

REVISIONS

C

Description MIDTERM FINAL

Date 3/24/2022 5/12/2022

620 N Santiago St, Santa Ana, CA 92701

SANTA ANA HOUSING

D

Issued by J.P. J.P.

MIXED-USE MULTI-FAMILY COMPLEX

No. 01 02

B

620 N Santiago St, Santa Ana, CA 92701

EXTERIOR BUILDING VISUALIZATION A

PROJECT NUMBER

A1

EXTERIOR BUILDING VISUALIZATION

DATE

M4 12 MAY 2023

ISSUED BY

A.S.

CHECKED BY

A.S.

A-411 Scale

AS INDICATED


2

E

3

4

5

1' - 0"

1

63

62

61

60

59

58

T.O. LEVEL 3

3801 W Temple Ave Pomona, CA 91768 jpajer@cpp.edu (916) 693-9027

8' - 11"

28' - 0"

B4 A-420

Consultant: Anton Schneider 3801 W Temple Ave, Pomona, CA 91768 abschneider@cpp.edu (916) 693-9027 1 INCH NOSING REVISIONS CONCRETE TREAD

D

1' - 0" 1' - 0"

2 INCH NON-SLIP STRIP 45

No. 01 02

Issued by J.P. J.P.

Description MIDTERM FINAL

Date 3/24/2022 5/12/2022

BENT METAL SHEET

44

3' - 3"

43

42

STRINGER

41

40

T.O. PODIUM

C

6' - 9"

1' - 0"

5' - 6"

3' - 0"

56

55

54

B4

3' - 8"

53

52

STAIR DETAIL 3" = 1'0"

51

DN

50

48

4' - 7"

4' - 11"

49

620 N Santiago St, Santa Ana, CA 92701

STAIR SECTION 1/2" = 1'0"

MIXED-USE MULTI-FAMILY COMPLEX

B2

SANTA ANA HOUSING

18' - 0"

47

B

3' - 4"

46

620 N Santiago St, Santa Ana, CA 92701

UP

B1 A-420

40

41

42

43

44

45

ENLARGED STAIR PLAN AND SECTION

30" BY 40" AREA OF REFUGE

A1

A

STAIR PLAN 1/2" = 1'-0"

PROJECT NUMBER

M4 12 MAY 2023

DATE ISSUED BY

A.S.

CHECKED BY

A.S.

A-420 Scale

AS INDICATED


1

E

2

3

WA-01

WA-02

R-0 MIN. R- 24.7 STC: 36

R-0 MIN. R- 18.7 STC: 57

4

5

WA-03 R-0 MIN. R- 23.8 STC: NONE

CEMENT PANELS Z FURRING CHANNEL

FURRING STRIPS

SECTION

SECTION

PLYWOOD SHEATING 2 X 6 STUD

AIR SPACE

GYPSUM WALLBOARD AIR GAP 2 X 4 STUD

MINERAL WOOL INSULATION

WEATHER RESISTANT BARRIER

GYPSUM WALLBOARD

GYPSUM WALLBOARD

PLYWOOD SHEATHING

Consultant: Anton Schneider 3801 W Temple Ave, Pomona, CA 91768 abschneider@cpp.edu (916) 693-9027

MINERAL WOOL INSULATION

PLYWOOD SHEATING

RIGID INSULATION

3801 W Temple Ave Pomona, CA 91768 jpajer@cpp.edu (916) 693-9027

GYPSUM WALLBOARD

2 X 6 STUD

REVISIONS

RA-01

PVC MEMBRANE

INT WOOD FLOORING PLYWOOD SHEATHING

R-0 MIN. R- 50.3 STC: N/A

C1 1

WOOD DECKING SLEEPER SLEEPER SLEEPER RIGID INSULATION PLYWOOD SHEATHING MINERAL WOOL INSULATION 2 X 12 STUD GYPSUM WALLBOARD

2 X 12 STUD

GYPSUM WALLBOARD SECTION

SLOPE 1/4 : 12

MINERAL WOOL INSULATION

FLOOR STUD

INT

EXT

RIGID INSULATION PLYWOOD SHEATHING

INT.

GYPSUM WALLBOARD

INT

Date 3/24/2022 5/12/2022

INT

GYPSUM ROOFING MATERIAL

MINERAL WOOL INSULATION

C

16' O.C. TYP.

PLAN

EXT.

INT

Description MIDTERM FINAL

SECTION

SECTION

ASSEMBLIES 1 1/2" = 1'-0"

620 N Santiago St, Santa Ana, CA 92701

16" O.C. TYP

INT

Issued by J.P. J.P.

SANTA ANA HOUSING

R-0 MIN. R- 38.3 IRC: 53

INT

INT

FA-01

16" O.C. TYP

GYPSUM WALLBOARD

No. 01 02

RA-02

EXT

PLYWOOD SHEATHING PLAN

PLAN

D

16" O.C. TYP.

MINERAL WOOL INSULATION

MIXED-USE MULTI-FAMILY COMPLEX

SECTION

ANCHOR

GYPSUM WALLBOARD

B

620 N Santiago St, Santa Ana, CA 92701

ASSEMBLIES

A

PROJECT NUMBER DATE

M4 12 MAY 2023

ISSUED BY

A.S.

CHECKED BY

A.S.

A-501 Scale

AS INDICATED


1

2

3

4

5

E GALV. SHT. CAP FLEXIBLE FLASHING TOP PLATE WEATHER RESISTANT MEMBRANE SEAL TAPE

WA-01

PLYWOOD SHEATHING WEATHER RESISTANT MEMBRANE CEMENT PANELS VERTICAL FURRING STRIPS WATERPROOFING TERMINATIONS WOOD PLANK DECKING SLEEPERS PVC MEMBRANE SLOPE 1/4 : 12 RIGID INSULATION

ANCHOR BOLT BASEBOARD MOLDING ENGINEERED FLOORING PLYWOOD SHEATHING

WEATHERING RIGID VINYL SPACER TRI-FIN PILE HEAD TRACK PAN FLASHING

Consultant: Anton Schneider 3801 W Temple Ave, Pomona, CA 91768 abschneider@cpp.edu (916) 693-9027

ALUMINUM SLIDING DOOR ALUMINUM THRESHOLD WOOD NAILER

REVISIONS No. 01 02

D

Date 3/24/2022 5/12/2022

WALL TO PODIUM 1 1/2" = 1'-0"

C3

BALCONY FLOOR 1 1/2" = 1'-0"

C4

WALL TO ROOF 1 1/2" = 1'-0"

C

TUBE STEEL

620 N Santiago St, Santa Ana, CA 92701

WA-01

SANTA ANA HOUSING

C1

Description MIDTERM FINAL

SLOPE 1/4 : 12

FA-01

SUPPORTS FLASHING ALUMINUM PLATE ALUMINUM HEADER SEALANT FASTENER GLAZING

Issued by J.P. J.P.

MIXED-USE MULTI-FAMILY COMPLEX

ANCHOR Z CLIPS FLASHING SEALANT

3801 W Temple Ave Pomona, CA 91768 jpajer@cpp.edu (916) 693-9027

WIRE MESH TENSION CABLE

B

ANGLED SLEEPERS

SHELF SPACE EXT

RIM JOISTS

SLOPE EXT 1/4 : 12

4" MIN

STRAINER HIGH

FA-01

DA-01

RA-01

SLOPE 1/4 - 12

INT

LOW

GLASS SKYLIGHT STEEL FRAME

620 N Santiago St, Santa Ana, CA 92701

METAL GUTTER CUSTOM STEEL CHANNEL

INT

INT

SKYLIGHT DETAIL A1 1 1/2" = 1'-0"

A

GUARDRAIL DETAIL A3 1 1/2" = 1'-0"

DETAILS

SKYLIGHT DRAINAGE DETAIL A4 1 1/2" = 1'-0"

PROJECT NUMBER DATE

M4 12 MAY 2023

ISSUED BY

A.S.

CHECKED BY

A.S.

A-502 Scale

AS INDICATED


1

2

3

4

E

5

STEEL PIPE GUARDRAIL TENSION CABLE TIES

3801 W Temple Ave Pomona, CA 91768 jpajer@cpp.edu (916) 693-9027

WIRE MESH

Consultant: Anton Schneider 3801 W Temple Ave, Pomona, CA 91768 abschneider@cpp.edu (916) 693-9027

GLASS SKYLIGHT REVISIONS

STEEL FRAME

D

No. 01 02

WELDED CONNECTION

Issued by J.P. J.P.

Description MIDTERM FINAL

Date 3/24/2022 5/12/2022

METAL GUTTER CUSTOM STEEL CHANNEL

SKYLIGHT DRAINAGE DETAIL

WEATHER RESISTANT BARRIER

NTS

C

CEMENT PANELS SLEEPERS AIR GAP RIGID INSULATION PLYWOOD SHEATHING

WOOD PLANKS PLYWOOD SHEATHING SLEEPER PLYWOOD SHEATHING FLOOR JOIST FIBER WOOL INSULATION

WEATHER RESISTANT BARRIER WEATHER RESISTANT BARRIER B3

B

GUARDRAIL DETAIL NTS

620 N Santiago St, Santa Ana, CA 92701

C1

SANTA ANA HOUSING

ANGLED FURRING STRIPS

MIXED-USE MULTI-FAMILY COMPLEX

FIBER CEMENT PANEL

GYPSUM DRYWALL PLYWOOD SHEATHING FIBER WOOL INSULATION ENGINEERED WOOD FLOORING

620 N Santiago St, Santa Ana, CA 92701

DOUBLE RIM JOIST

WOOD PLANKS SLEEPERS PVC MEMBRANE

3D - DETAILS

A

A1

STUDIO SKYLIGHT DETAIL NTS

PROJECT NUMBER DATE

M4 12 MAY 2023

ISSUED BY

A.S.

CHECKED BY

A.S.

A-503 Scale

AS INDICATED


1

2

3

4

5

E

3801 W Temple Ave Pomona, CA 91768 jpajer@cpp.edu (916) 693-9027

Consultant: Anton Schneider 3801 W Temple Ave, Pomona, CA 91768 abschneider@cpp.edu (916) 693-9027

REVISIONS

C

Description MIDTERM FINAL

Date 3/24/2022 5/12/2022

620 N Santiago St, Santa Ana, CA 92701

SANTA ANA HOUSING

D

Issued by J.P. J.P.

MIXED-USE MULTI-FAMILY COMPLEX

No. 01 02

B

620 N Santiago St, Santa Ana, CA 92701

MODEL PHOTOS

A

PROJECT NUMBER DATE

A1

MODEL PHOTOS

M4 12 MAY 2023

ISSUED BY

A.S.

CHECKED BY

A.S.

A-505 Scale

AS INDICATED


1

2

3

13' - 4"

4

5

9' - 4"

FIXED

FIXED

FIXED

FIXED

7' - 6"

7' - 6"

E

FIXED

FIXED

3801 W Temple Ave Pomona, CA 91768 jpajer@cpp.edu (916) 693-9027

FIXED

Consultant: Anton Schneider 3801 W Temple Ave, Pomona, CA 91768 abschneider@cpp.edu (916) 693-9027

2

1

REVISIONS

HEIGHT

WINDOW TYPE

MATERIAL

1

13'-4"

7'-6"

HINGED

ALUMINUM

2

9'-4"

7'-6"

HINGED

ALUMINUM

MANUFACTURER

NOTES

WINDOW SCHEDULE 1/2" = 1'-0"

C

13' - 4"

FIXED

B

TYP. 1

A

7' - 6"

3' - 6"

3' - 6"

7' - 0"

7' - 6"

3' - 0"

7' - 0"

2' - 8"

9' - 4"

TYP. 2

FIXED

TYP. 3

TYPE

WIDTH

HEIGHT

1

2'-8"

7'-0"

DOOR TYPE HINGED

MATERIAL

FIXED

FIXED

TYP. 4

MANUFACTURER

620 N Santiago St, Santa Ana, CA 92701

NOTES

WOOD

2

3'-0"

7'-0"

HINGED

ALUMINUM

3

13'-4"

7'-6"

SLIDING

ALUMINUM

DOOR AND WINDOW SCHEDULE

PROJECT NUMBER DATE

4 A1

DOOR SCHEDULE 1/2" = 1'-0"

9'-4"

7'-6"

SLIDING

Date 3/24/2022 5/12/2022

620 N Santiago St, Santa Ana, CA 92701

WIDTH

Description MIDTERM FINAL

MIXED-USE MULTI-FAMILY COMPLEX

C1 1

TYPE

Issued by J.P. J.P.

SANTA ANA HOUSING

D

No. 01 02

ALUMINUM

M4 12 MAY 2023

ISSUED BY

A.S.

CHECKED BY

A.S.

A-600 Scale

AS INDICATED


1

2

3

4

5

E

3801 W Temple Ave Pomona, CA 91768 jpajer@cpp.edu (916) 693-9027

58 A

11 B

Consultant: Anton Schneider 3801 W Temple Ave, Pomona, CA 91768 abschneider@cpp.edu (916) 693-9027

12 C

28' - 8"

REVISIONS

14' - 0"

14' - 0"

No. 01 02

Description MIDTERM FINAL

Date 3/24/2022 5/12/2022

LT - 03

D

Issued by J.P. J.P.

13 1

+ CLG. HT. 7'- 6"

15' - 0"

LT - 02

+ CLG. HT. 7'- 6"

LT - 04

LT - 04

LT - 04

LT - 02

LT - 03

+ CLG. HT. 7'- 6"

15 3

GFCI

LT - 02

LT - 02

LT - 02

GFCI

LT - 01

LT - 03

620 N Santiago St, Santa Ana, CA 92701

LT - 04

+ CLG. HT. 8'- 6"

MIXED-USE MULTI-FAMILY COMPLEX

SANTA ANA HOUSING

LT - 04 + CLG. HT. 7'- 6" LT - 03

14 2

+ CLG. HT. 8'- 6"

D

LT - 04

C

D

LT - 03

10' - 0"

LT - 04

LT - 03

KEY

B

RECESSED DOWNLIGHT

HATCH INDICATES SOFFIT

UNDER CABINET MOUNTED LINEAR LIGHTING

LINE INDICATES WIRED CONNECTION

LT - 01

LT - 02 LT - 03

LT - 04

ELECTRICAL REFLECTED CEILING PLAN 1 BED B2 1/4" = 1'-0"

D

WALL MOUNTED LINEAR LIGHT - LARGE

PENDANT LIGHT

WALL MOUTED SINGLE SWITCH

GFCI

WALL MOUNTED GFCI DUPLEX

WALL MOUNTED DATA

WALL MOUNTED DUPLEX

620 N Santiago St, Santa Ana, CA 92701

LT - 07

POWER, ELECTRICAL, AND LIGHTING PLANS A

PROJECT NUMBER DATE

M4 12 MAY 2023

ISSUED BY

A.S.

CHECKED BY

A.S.

E-102 Scale

AS INDICATED


1

2

3

4

5

E

CONDENSER

3801 W Temple Ave Pomona, CA 91768 jpajer@cpp.edu (916) 693-9027

ELECTRICAL PANEL METER

A

CITY GRID SUPPLY OUTFLOW RETURN INTAKE

B

SUPPLY OUTFLOW

Consultant: Anton Schneider 3801 W Temple Ave, Pomona, CA 91768 abschneider@cpp.edu (916) 693-9027

C

28' - 8" 14' - 0"

14' - 0" REVISIONS No. 01 02

D

SUPPLY OUTFLOW RETURN INTAKE

Issued by J.P. J.P.

Description MIDTERM FINAL

Date 3/24/2022 5/12/2022

SUPPLY OUTFLOW

+ CLG. HT. 8'-6"

+ CLG. HT. 8'-6"

+ CLG. HT. 7'-6"

15' - 0"

+ CLG. HT. 7'-6"

+ CEILING HT 7'-6"

3

620 N Santiago St, Santa Ana, CA 92701

SUPPLY OUTFLOW

2

C

SANTA ANA HOUSING

RETURN INTAKE

30' - 11"

SUPPLY OUTFLOW

CEILING HT 7'-6"

MIXED-USE MULTI-FAMILY COMPLEX

10' - 0"

1

B HVAC SECTION DIAGRAM B1 1/4" = 1'-0"

MECHANICAL REFLECTED CEILING PLAN 1 BED B3 1/4" = 1'-0" 620 N Santiago St, Santa Ana, CA 92701

KEY SUPPLY RETURN

HVAC DISTRIBUTION PLAN

12" X 12" DUCT

EXHAUST HATCH INDICATES SOFFIT

A

PROJECT NUMBER DATE

M4 12 MAY 2023

ISSUED BY

A.S.

CHECKED BY

A.S.

M-101 Scale

AS INDICATED


1

2

3

4

5

E

BOILER HOT LINE

3801 W Temple Ave Pomona, CA 91768 jpajer@cpp.edu (916) 693-9027

COLD LINE

CIRCUL ATION PUMP

Consultant: Anton Schneider 3801 W Temple Ave, Pomona, CA 91768 abschneider@cpp.edu (916) 693-9027

58 A

11 B

12 C

28' - 8" 14' - 0"

D

REVISIONS 14' - 0" 7' - 6"

SINK

Description MIDTERM FINAL

Date 3/24/2022 5/12/2022

620 N Santiago St, Santa Ana, CA 92701

15' - 0"

14 2

30' - 7"

C

MIXED-USE MULTI-FAMILY COMPLEX

13 1

WATER CLOSET

SANTA ANA HOUSING

WASHER/ DRYER STACKED

Issued by J.P. J.P.

10' - 0"

SINK

2' - 9"

No. 01 02

15 3 B FRESH WATER MAIN

SEWER MAIN

PLUMBING DIAGRAM B1 1/4" = 1'-0"

WATER METER PER UNIT

620 N Santiago St, Santa Ana, CA 92701

PLUMBING REFLECTED CEILING PLAN 1 BED B3 1/4" = 1'-0"

KEY

PLUMBING DISTRIBUTION PLAN

EXHAUST VENT COLD WATER LINE HOT WATER LINE

A

WASTE WATER HATCH INDICATES PLUMBING WALL

PROJECT NUMBER DATE

M4 12 MAY 2023

ISSUED BY

A.S.

CHECKED BY

A.S.

P-101 Scale

AS INDICATED