Aeolus Cavity Batten - Installation Guide

Page 1

VCB1S5 HORIZONTAL CAVITY BATTEN

Product

Treatment

Size

Length

Pieces per Pack

VCB1S5

H3

65 x 35mm

5.4 metres

99

NCC 2025 Incorporating the Aeolus Ventilated Cavity Batten into an external wall will meet the rthe requirements of the NCC 2025 Housing Provisions Section 10.8.1

High Compressive Strength Capable of withstanding over 1 tonne of uniformly distributed load along each lineal metre batten

High Ventilation Capacity The VCB1S5 provides >3,700 mm2 per metre of ventilation. 3.7 times the requirements of NCC 2025 of >1,000 mm2 per metre

H3 Veneer Treated LVL Core Every veneer in the LVL core is treated prior to laminating and pressing - genuine protection against decay, mould and insect infestation

Continuous Drainage The hollow core drainage feature eliminates locations where moisture can build up and cause rot or decay to either the batten or the external cladding

Light weight, long length Efficient use of wood fibre equates directly to reduced weight. Each 5.4 metre piece of VCB1S5 weighs approximately 6kg

Aeolus Ventilated Cavity Battens can be used for any external lightweight wall cladding system requiring a horizontal, ventilated cavity batten per the requirements of National Construction Code Housing Provisions Part 10.8 Condensation Management

LVL Core Details: AS/NZS 4357.0 - A-Bond - Super E0 - 476 64 H3V

ISSUE 1.0 - OCTOBER 2026


Detail 1 - Batten Fall Direction

Install with the slope directing moisture outwards, towards the cladding face

A up ng faci text e front all Inst is is th Th

A

Detail 2 - Fixing Penetration

Fixings to penetrate through outer hollow core structure

Detail 3 - Cladding to Batten Fixings

Minimum length of fixing penetrating into cavity batten: 10x fixing thickness + 5mm

up ng faci text e front all Inst is is th Th

Detail 4 - External Corner Detail

B

Cladding Corner Detail Min. 2mm Control Gap Aeolus Cavity Batten Wall Framing up ng faci text e front all Inst is is th Th

Detail 5 - Internal Corner Detail

B

Wall Framing Min. 2mm Control Gap Cladding Corner Detail Aeolus Cavity Batten up ng faci text e front all Inst is is th Th

B

Detail 6 - Batten Cantilever A (Table Below)

A/3

Maximum cantilever equals designed wall stud spacings divided by 3

35mm Cavity Closer or fire protection as required by others

Max. Wind Classification

B - Max. Batten Spacing

N2

900mm

N3

C2 C3

A - Maximum Stud Spacings Timber Framing - JD5 minimum 450mm

600mm

2 / 3.15x75mm Nails or

2 / 3.15x75mm Nails or

1 / 10gx60mm Screws

1 / 10gx60mm Screws

2 / 3.15x75mm Nails or

2 / 3.15x75mm Nails or

1 / 10gx60mm Screws

1 / 10gx60mm Screws

900mm

1 / 10gx60mm Screws

1 / 10gx60mm Screws

450mm

Steel Framing - 0.75BMT minimum 450mm

600mm

1 / 10gx45mm Screw

1 / 10gx45mm Screw

1 / 10gx45mm Screw

1 / 10gx45mm Screw

1 / 10gx45mm Screws

2 / 10gx45mm Screws

450mm

1 / 10gx60mm Screws

1 / 10gx60mm Screws

1 / 10gx45mm Screws

2 / 10gx45mm Screws

900mm

1 / 10gx60mm Screws

2 / 10gx60mm Screws

2 / 10gx45mm Screws

2 / 14gx45mm Screws

450mm

1 / 10gx60mm Screws

2 / 10gx60mm Screws

1 / 14gx45mm Screws

2 / 14gx45mm Screws

ISSUE 1.0 - OCTOBER 2026