Skip to main content

Three Phase AC to DC Boost Converter Using D-Q Theory

Page 1

INTERNATIONAL RESEARCH JOURNAL OF ENGINEERING AND TECHNOLOGY (IRJET) VOLUME: 04 ISSUE: 02 | FEB -2017

E-ISSN: 2395 -0056

WWW.IRJET.NET

P-ISSN: 2395-0072

Three Phase AC to DC Boost Converter Using D-Q Theory MAHADEV R. HADIAL Department of Electrical Engineering Vadodara Institute of Engineering Gujarat, India. ----------------------------------------------------------------------------***----------------------------------------------------------------------------Abstract—Thyristor Bridge rectifiers are employed The merits of the current controlled boost converter to obtain dc regulated voltage from ac main. These are: rectifiers are inject harmonics in the utility, it has  It is provides near sinusoidal currents, thus been overcome by passive or active filter but it is avoiding expensive low harmonics filters costly and bulky.This paper presents three phase AC  It is accomplished of unity power factor to DC boost bidirectional converter using DQ theory operation thus offering the option of power based current control loop. This converter provide factor compensation constant DC boost voltage from 3 phase AC voltage by closed loop control. This converter has boosted DC voltage with unity input power factor and harmonics free source current. Results are obtained Sa+ Sb+ Sc+ by computer simulation/MATLAB. R L

AC

Index Terms— bidirectional converter, DQ theory, harmonics, power factor correction.

C + AC

Earlier time thyristor Bridge rectifiers are employed to obtain dc regulated voltage from ac main. These rectifiers pollute the utility with low-order harmonics, which are difficult to filter. The continuous use of thyristor Bridge rectifiers injects current harmonic components into the power grid and increases reactive power demands and power system voltage fluctuations. Harmonic current components create several problems like Increase in power system losses. Oscillatory torques in rotating machinery. Significant interference with communication circuits that share common right-ofways with AC power circuits, Overheating and insulator failures in transformers, rotating machinery, conductor and cables. Generates noise on regulating and control circuits causing erroneous operation of such equipment. Reactive power burden, low system efficiency, poor power factor, system unbalance and causes excessive neutral currents. Malfunctioning of the protective relays and untimely tripping, Failure of capacitor banks [4]. Modern three phase AC to DC converter researches have focused on providing a good input power factor and low line current harmonics distortion in order to satisfy different harmonic standards [2][4]. The PWM bidirectional converter draws a near sinusoidal input current while providing a regulated output dc voltage and can operate in the first and second quadrants of the voltage–current plane. Mostly, the control structure of a three-phase six switch PWM boost converter consists of an inner current and an outer voltage control loop

|

Impact Factor value: 5.181

L

AC

I. INTRODUCTION

© 2017, IRJET

Vdc

Sa-

Sc-

Sb-

Fig.1 Three Phase AC to DC Boost Converter with R-L Load

II. DQ REFERENCE CURRENT GENERATION AND HYSTERESIS CURRENT CONTROL

This method of reference current generation is developed in time domain based reference current generation. This theory is extensively used as it simplicity of the calculations, and uses only algebraic calculation. The three phase source current (Isa, Isb, and sc) are transformed into the two instantaneous active (id) and reactive (iq) components in a rotating frame synchronous with the positive sequence of the system voltage. It can be represented by the set of equations. The basic working principle of SRF methods uses a direct (d-q) and inverse (d-q) park transformation method, which allow the evaluation of a specific harmonic component of the input signals.

|

ISO 9001:2008 Certified Journal

|

Page 1484


INTERNATIONAL RESEARCH JOURNAL OF ENGINEERING AND TECHNOLOGY (IRJET) VOLUME: 04 ISSUE: 02 | FEB -2017

E-ISSN: 2395 -0056

WWW.IRJET.NET

P-ISSN: 2395-0072

Vdc -

Vdc* +

PI

+

d

Isa Isb Isc

abc to dq0

Sa+

q

dq0 to abc

0

Hysteresis band Current controller

SaSb+ Sb-

Fig.4 Hysteresis-Band Control

Sc+ Sc-

The hysteresis-band controller is used for the current control. After the inverse transform a-b-c current component is used for error. As the error exceeds a prescribed hysteresis band, the upper switch is turned off and the lower switch is turned on. As a results, the output voltage transitions from 0.1 to -0.1 V and the current starts decay. As the error crosses the lower band limit, the lower switch is turned off and the upper switch is turned on.

Vs PLL

Sin_Cos

Fig.2 Control using D-Q Theory

The reference frame transformation is evaluated by converting a three-phase a - b - c stationery system to the two- phase direct axis (d) – quadratic axis (q) component rotating coordinate system. These three (a-bc) phase space vectors stationary coordinates are easily transformed into two axis d-q rotating reference frame   cos  id   i  2    q  3   sin   i0    1  2

2 2  ) cos(  )  3 3  ia  2 2     sin(  )  sin(  ) ib  3 3    ic  1 1  2 2 

III. SIMULATION RESULTS Simulation result is done using MATLAB/Simulink. Figure shows the Simulink diagram of bidirectional boost converter with R-L load. The diagram consists power circuit having bidirectional IGBT switches based converter with dc link capacitor and R-L load and control block which include D-Q theory reference current calculation and hysteresis current controller based switching pulse generation.

cos( 

(1)

+ -i Discre te , Ts = 5e -06 s.

The output of the transformation depends on the source currents (fundamental and harmonic frequency components) and on phase locked loop. The PLL circuit of rotation speed (rad/sec) of the rotating reference frame ωt set as fundamental frequency component. The PLL circuit is providing sin θ and cos θ for synchronization [6]. The isq current component is applied to inverse transformation is used to compensate the reactive power. The dc side capacitor voltage of rectifier kept constant and controlled by using PI controller. PI controller output is then subtracted from the direct axis (d axis) component. The method is further developed to get the desired reference current in d-q rotating frame is converted back into a - b - c stationery frame. This ways reference current can be generated in a very easy method. The inverse transformation from d - q rotating frame to a - b – c stationery frame is achieved by the following equation [6].  cos  ia   i    cos(  2 )  b  3  ic   2 ) cos(  3 

 1 id  2    sin(  ) 1  iq  3  1  i0  2  sin(  )  3 

© 2017, IRJET

|

g1

g5

a b c

700

Is

Vs

+

g

C

+

E

C

g4

g6

In1

Out1

g1

Out2

g2

Out3

g3

Out4

g4

Out7

g5

Out8

g6

In2

g

C

c

E

[Vdc1]

In3

In4

Control

Fig.5 Simulink Diagram of AC to DC bidirectional Converter Table.1 Parameters Used for Simulation

Parameters Source C

L (source side) Load DC reference PI gain

(2)

|

Values 440 VAC, 50hz 500µF 10mH 100 Ω, 10mH 700 Kp = 1 Ki = 0.00001

ISO 9001:2008 Certified Journal

+ - v

[Vdc1] g2

E

C

A B C

g

C

Vabc Iabc a b

C

B

E

A

B

g

A

C

N

E

g

E

C

g

Vs Is

 sin 

Impact Factor value: 5.181

g3

|

Page 1485


INTERNATIONAL RESEARCH JOURNAL OF ENGINEERING AND TECHNOLOGY (IRJET) VOLUME: 04 ISSUE: 02 | FEB -2017

E-ISSN: 2395 -0056

WWW.IRJET.NET

P-ISSN: 2395-0072

Table.2 Source Current with DC load current

Load R (ohm) L (mH) 100 10 100 5 50 5 50 10 500 10 500 0

Source Current THD% 1.19 1.19 0.85 0.84 5.62 5.55

Idc (amp) 6.91 6.91 13.66 13.66 1.40 1.40

IV. CONCLUSION This paper presents three phase AC to DC boost bidirectional converter using DQ theory based current control loop. This converter provide constant DC boost voltage from 3 phase AC voltage by closed loop control. This converter has boosted DC voltage with unity input power factor and harmonics free source current. REFERENCES [1] Boon Tech Ool, Juan W. Dixon, Ashok B. Kulkarni, Masahiro Nishimoto, “An Integrated AC Drive System Using A Controlled Current PWM Rectifier/Inverter Link”, IEEE Transactions On Power Electronics, Vol. 3, No.1, Jan 1988. [2] Jun Kikuchi, Thomas A. Lipo, “ Three Phase PWM Boost Buck Rectifiers With Power Regeneration Capability”, IEEE Transaction On Industry Applications, Vol. 38, No. 5, September/October 2002 [3] J S Siva Prasad, Tushar Bhavsar, Rajesh Ghosh and G Narayanan, “Vector Control Of Three-Phase AC/DC FrontEnd Converter”, Sadhan A Vol. 33, Part 5, October 2008, Pp. 591–613. [4] Dharmraj V. Ghodke, Sreeraj E. S., Kishore Chatterjee, And B. G. Fernandes,” One-Cycle-Controlled Bidirectional Acto-Dc Converter With Constant Power Factor”, IEEE Transactions On Industrial Electronics, Vol. 56, No. 5, May 2009.

Fig.6 Waveform of DC link Voltage and Current

Fig.7 Source Voltage and Current

In the figure shows source current and voltage are in phase and current is all most sinusoidal so power factor is unity.

[5] G.Mohan Babu, “Simulation Study of Indirect Current

Control Technique for Shunt Active Filter”, International Journal of Engineering Research and Applications (IJERA) ISSN: 2248-9622 Vol. 3, Issue 4, Jul-Aug 2013, pp.831-851. [6] Neha Kumari, Isha Awashthi “Harmonic Compensation Using Shunt Active Power Filter in Power System Using Matlab”, International Journal of Scientific Engineering and Research, Volume 1 Issue 3, November 2013. [7] S. S. Wamane, J.R. Baviskar, S. R. Wagh, “A Comparative Study on Compensating Current Generation Algorithms for Shunt Active Filter under Non-linear Load Conditions”, International Journal of Scientific and Research Publications, Volume 3, Issue 6, June 2013.

Fig.8 FFT analysis of source current

© 2017, IRJET

|

Impact Factor value: 5.181

|

ISO 9001:2008 Certified Journal

|

Page 1486