1 minute read

International Journal for Research in Applied Science & Engineering Technology (IJRASET)

ISSN: 2321-9653; IC Value: 45.98; SJ Impact Factor: 7.538

Advertisement

Volume 11 Issue I Jan 2023- Available at www.ijraset.com

Figure 3 represents the relationship between the net power generated and ambient temperature. This relationship is governed by the straight-line equation

=333888 50804997 (25) where is the net power generated by the plant and is the ambient temperature.

It shows that there is an increase of 33.3888kW in the net power generated for every 1o rise in the ambient temperature.

Figure 4 shows a similar increase in the heat rate of the gas turbine power plant. The relationship between the heat rate and ambient temperature is governed by the straight-line equation

=287077 +413221021 (26) where is the power plant heat rate and is the ambient temperature.

This article is from: