OPERATING INSTRUCTIONS
Step 8
When the engine starts, check the oil pressure indicator and charge indicator. If the indicators stay on, stop the engine and find out what is wrong.
Turn key switch to start position until engine starts, but no more than 10 seconds, then release the key. Run engine for two minutes at 1500 RPM.
NOTE: If the oil pressure indicator stays on after the engine starts, stop the engine and check the oil level in the crankcase. Add oil if necessary. Start the engine, if the indicator is still on, do not operate the engine. Operating the engine without oil pressure will damage engine bearings and other engine parts. See your dealer.
IMPORTANT:
1.If high idle position is used for starting, adjust the engine speed control lever to obtain about 1500 RPM as soon as the engine starts.
2.If the engine starts and then stops, wait for the starting motor to stop turning before you turn the key switch to START position again.
3.Do not use the starter motor for more than 10 seconds without stopping. Wait one minute between starts so the starter motor can cool.
4.If the engine stops when operating with a load, immediately start the engine again to prevent overheating caused by stopping the flow of oil for cooling and lubrication.
5.If the charge indicator comes on during operation, determine and correct the cause to avoid complete discharge of the battery and possible damage to other components of the electrical system. See your Dealer.
6.If the coolant temperature indicator comes on, remove the load and allow the engine to run at 1500 rpm until the indicator goes out. If the indicator does not go out within one minute, stop the engine and determine the cause.
Starting Procedure for Hydrostatic Drive Tractors
After Transporting on Truck or Flatcar
IMPORTANT: Hydrostatic transmission can jump into gear without warning, if the fluid leaks out of the control system. This can occur due to vibration if the tractor is transported on a truck or rail car. It can also happen if the transmission is drained or if the tractor sits still for very long perIods. If any of these have happened, start the tractor as follows:
1.Put the range shift control lever into the N (Engine start) slot and release the speed lock lever to permit the speed ratio control pedal to return to N (Neutral) position.
2.Lock the brake pedals together, press down on the brake pedals.
3.Pull the engine speed control lever and start the engine. Set the engine speed to about 1000 RPM.
4.Slowly move the range shift lever to H range for high speed engagement.
If gear clash is obvious the engine should be shut off immediately and the tractor unloaded by other means. Tow the tractor with the range shift lever in N (Neutral) to an area where the transmission can be checked by your Dealer. Refer to Towing the Tractor in this manual.
If there is no obvious gear clash, drive the tractor in the normal manner.