1 minute read
V. OPERATING INFORMATION
HAGIE TASSELTROL® CONTINUED
T, and D are typically set as shown in figure 5.34. The machine type will vary from o, p, or c depending on the valve system. Also, the L will vary depending on the number of lifts on the machine.
2. Match the machine valve type:
Press the LIFT 1 up button under the PAR on the LCD display window two times (fig. 5.34) and the display will show you the machine type that is selected (fig. 5.35). The “o”, “p”, or “c” just to the right of the NEXT on the bottom line of the LCD display indicates the type of machine. To change the type of machine, press the LIFT 2 up button that is located under this item. The display will now change to the SELECT MACHINE TYPE screen (fig. 5.36). Select the type of machine that this unit is installed on. For a machine prior to 2007, with the original valve system press the LIFT 4 button under “o”. If the machine has the new proportional valves press the LIFT 5 button under the “p”. If the machine is a 2007 or newer STS combination sprayer– detasseler with the proportional valves, press the LIFT 6 button under the “c”.
The screen will now revert back to the SELECT MANUAL screen with the machine type that you have just selected displayed on the bottom line.