V. OPERATING INFORMATION
SETTING UP THE HAGIE TASSELTROL®/LS SYSTEM 12™
Initial Set Up
1. Enter the Parameter Mode:
Select AUTO by placing the AUTO/ MAN. switch (fig. 5.32, item 1) in the AUTO position. Now turn on the DEPTH CONTROL (fig. 5.31) by placing the ON/OFF switch (fig. 5.32, item 2) in the ON position. In the LCD display window (fig. 5.33), there will be four lines. The top line displays the program level. The second line will flash SELECT MANUAL as a warning that you are about to enter the parameter adjusting mode.
The current parameter settings are displayed on the bottom line of the window. The values for B, R,
*NOTE: Machines with a Tasseltrol® software version level C8.7 and greater have an enhancement that allows the operator to set the lift speeds for the auto mode functions (See instructions 5 and 7)