1 minute read
IDENTIFICATION OF HOLES AND PIPES ON RIGHT COVER..................................................................................E1
Hydraulics 110 l/min
Identification of holes and pipes on right cover
9
8
6
12 HP
GAV
7 6 9
13 8
9024
2
1
10
14 9 8 6 4
12
5 4
3 11
391hsm1f
Description
1 Adjustment screw, 22 bar. 2 Adjustment screw, 200 bar. 3 Main filter, 15 micron. 4 Boost. 5 Rear axle lubrication only. 6 High pressure from variable displacement pump. 7 High pressure outlet of variable displacement pump. 8 To variable displacement pump control piston.
9 Regulator return. 10 Return from priority unit(s)(depending on version). 11 Safety valve, 5 bar. 12 Pressure limiter, 230 bar. 13 Variable capacity pump regulator. 14 Safety valve, 24 bar. 9024 Load Sensing pressure connection.
Note: Screws (1) and (2) are factory set. Do not change these settings.
Fig. 49