IDENTIFICATION OF HOLES AND PIPES ON RIGHT COVER..................................................................................E1

Hydraulics 110 l/min

Identification of holes and pipes on right cover

9

8

6

12 HP

GAV

7 6 9

13 8

9024

2

1

10

14 9 8 6 4

12

5 4

3 11

391hsm1f

Description

1 Adjustment screw, 22 bar. 2 Adjustment screw, 200 bar. 3 Main filter, 15 micron. 4 Boost. 5 Rear axle lubrication only. 6 High pressure from variable displacement pump. 7 High pressure outlet of variable displacement pump. 8 To variable displacement pump control piston.

9 Regulator return. 10 Return from priority unit(s)(depending on version). 11 Safety valve, 5 bar. 12 Pressure limiter, 230 bar. 13 Variable capacity pump regulator. 14 Safety valve, 24 bar. 9024 Load Sensing pressure connection.

Note: Screws (1) and (2) are factory set. Do not change these settings.